IR 05000445/1993029

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Repts 50-445/93-29 & 50-446/93-29 on 930712-16 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Physical Security Program
ML20046C464
Person / Time
Site: Comanche Peak  
Issue date: 08/02/1993
From: Murray B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20046C457 List:
References
50-445-93-29, 50-446-93-29, NUDOCS 9308110048
Download: ML20046C464 (3)


Text

.

DOCUMENT CONTAINS APPENDIX U.S. NUCLEAR REGULATORY COMMISSION

REGION IV

Inspection Report:

50-445/93-29 50-446/93-29 Operating Licenses: NPF-87 NPF-89 Licensee: TV Electric Skyway Tower 400 North Olive Street, L.B. 81 Dallas, Texas 75201

'

Facility Name: Comanche Peak Steam Electric Station, Units 1 & 2 Inspection At:

Glen Rose, Texas i

Inspection Conducted: July 12-16, 1993 Inspector:

A. B. Earnest, Physical Security Specialist Facilities Inspection Programs Section

tj(AAOE Approved:

hurrhy,Gi6f, Facilities Inspection DAte I Blairi

,

Programs Section p Inspection Summar_y Areas Inspected (Units 1 and 2):

Routine, announced inspection of the-licensee's physical security program.

The areas inspected included records i

and reports, lock and key control, assessment aids, communications, security organization, and alarm stations.

Results (Units 1 and 2):

An excellent system of records and reports was maintained.

Required reporting was completed within the correct time frames (Section 1.1).

DOCUMENT CONTAINS ENCLOSURE CONTAINS UPON SEPARATION THIS PAGE IS DECONTROLLED l

i 9308110048 930805 PDR ADDCK 05000445 G

PDR,

.

_ _

.

i

,

-2-DOCUMENT CONTAINS ;

An adequate lock and key control system was maintained.

A failure to

identify employees terminated for cause and the decision not to issue security key rings to security officers were program weaknesses (Section 1.2).

The assessment aids system was tested and determined to provide

excellent assessment of the perimeter detection zones (Section 1.3).

An excellent communications capability was maintained (Section 1.4).

  • A very good security organization was maintained that was capable of

,

meeting security and contingency plan requirements (Section 1.5).

!

The alarm stations were redundant, well protected, and the operators

-

were alert and well trained (Section 1.6).

The licensee's security personnel did an excellent job preventing a-

weapon from entering the plant-(Section 2).

r Summary of Inspection Findings:

>

Inspection Followup Item 445/9329-01; 446/9329-01 was identified

(Section 1.2).

Inspection Followup Item IFI 445/9250-01; 446/9250-01 was reviewed but

not closed (Section 3).

'

Attachment:

Attachment - Persons Contacted and Exit Meeting

,

,

F

!

!

,

t

>

DOCUMENT CONTAINS ENCLOSURE CONTAINS l UPON SEPARATION THIS PAGE IS DECONTROLLED

!

!