IR 05000334/1998008

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-334/98-08 & 50-412/98-08
ML20248E525
Person / Time
Site: Beaver Valley
Issue date: 05/22/1998
From: Jason White
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Cross J
DUQUESNE LIGHT CO.
References
50-334-97-08, 50-334-97-8, 50-412-98-08, 50-412-98-8, NUDOCS 9806030352
Download: ML20248E525 (3)


Text

May 22, 1998

SUBJECT:

SUPPLEMENTAL RESPONSE TO NOTICE OF VIOLATION NO. 50-334/97-08-05and 50-412/97-08-05(REPLY)

Dear Mr. Cross:

This refers to your April 20,1998, correspondence in response to our letter, dated February 18,1998. Th! : correspondence dealt with a failure to establish adequate radiation monitoring syst, m as reviewed in accordance with NRC Inspection Module l

84750. We have reviewed this matter in accordance with NRC Inspection Manual Procedure 92904," Plant Support".

We consider your proposed plans to address this matter to be acceptable. We understand that you intend to incorporate a detailed discussion of RMS calibration techniques and processes, including the maximum and minimum operating high voltage for each detector type into appropriate implementing procedures and develop a method for determining RMS optimum high voltage. We will review the effectiveness of these actions in a future inspection.

We appreciate your cooperation.

<

Sincerely, l

ORIGINAL SIGNED BY:

r John R. White, Chief Radiation Safety Branch l

Division of Reactor Safety l

!

Docket Nos. 50-334,50-412

9906030352 980522 I

PDR ADOCK 05000334 I

G PDR f

TEo

_

_

__ -__ - - - -

__

-

--

_.

__

_

_ _ - - _ - _ _ _ _ _ _ _ _

- _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ -.

_ - - - _ _

__

(

-

. cc w/o encl:

Suchil C. Jain, Senior Vice President, Nuclear Services Group R. Brandt, Vice President, Nuclear Operations Group and Plant Manager R. LeGrand, Vice President, Operations Support Group B. Tuite, General Manager, Nuclear Operations Unit W. Kline, Manager, Nuclear Engineering Department M. Pergar, Acting Manager, Quality Services Unit J.' Arias, Director, Safety & Licensing Department-J. Macdonald, Manager, System and Performance Engineering cc w/ encl:

M Clancy, Mayor, Shippingport, PA Commonwealth of Pennsylvania State of Ohio State of West Virginia

).

L____________-___-__-_-__---__-_-

-

- - - - - -

-

r

'

l l

l 6,

,

l

'

Distribution w/ encl:

Region 1 Docket Room (with concurrences)

Nuclear Safety Information Center (NSIC)

!

PUBLIC NRC Resident inspector M. Evans, DRP N. Perry, DRP i

l D. Haverkamp, DRP

'

C. O'Daniell, DRP M. Oprendek, DRP J. Wiggins, DRS l

L. Nicholson, DRS l

DRS File B. McCabe, OEDO R. Capra, PD1-2, NRR D. Brinkman, PDI-2, NRR V. Nerses, PDl-2, NRR l

R. Correia, NRR F. Talbot, NRR DOCDESK Inspection Program Branch, NRR (IPAS)

DOCUMENT NAME: G:\\RSB\\ECKERT\\BVRESP.WPD Ta receive e copy of thie document,indcate in the box: 'C' - Copy without attachment / enclosure

"E" = Copy with attachment / enclosure

  • N"=

No copy

,

l OFFICE Rl:DRS

[

Rl:pRp l

l l

l

,

lNAME LEckert Le JM3 l DATE 5/f/98 5/$98

~

OFFICIAL RECORD COPY l

l

,

.

.

g Beaver Valley Power Station Shippingport, PA 15077-0004 i

!En*7v$/e*l.".*ni April 20,1998 l

Fax Ul*U*%*dimion L-98-075 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 Subject:

Beaver Valley Power Station, Unit No. I and No. 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Integrated Inspection Report 50-334/97-08 and 50-412/97-08 Supplemental Reply to Notice of Violation By letter dated January 9,1998, Duquesne Light Company (DLC) provided a response to the Notice of Violation (NOV) included with the subject inspection report dated November 26,1997. In this letter, DLC provided a basis for why DLC did not concur with Violation B (50-334/97-08-05), and requested that the violation be withdrawn. By letter dated February 18,1998, the NRC provided the conclusions ofits j

review of the DLC response to the NOV. In this letter, the NRC disagreed with DLC's

)

rationale for requesting the withdrawal of the violation, and requested that DLC provide l

an additional response to the violation by March 20,1998.

l On March 13, 1998, a telephone conference was held between members of the Region I staff and members of the DLC staff to discuss the violation. As a result of this discussion, it was agreed that an NRC site visit would be appropriate to further review the technical details of the radiation monitor system (RMS) calibration methods utilized

at Beaver Valley Power Station (BVPS). Based on this telephone conference and the planned NRC site visit, DLC by letter dated March 19,1998, requested an extension to the response to the February 18,1998, NRC letter until April 20,1998.

During the period of March 30,1998 to April 1,1998, an NRC Region I efDuents specialist conducted an inspection to further review the technical details of the RMS calib ation methods utilized at BVPS. This review determined that, while the method used at BVPS to perform the RMS calibrations is technically correct, the procedures used to perform the calibration are inadequate in that they lack sufficient detail about the current calibration techniques and processes.

DEllV'ERING QUALITY E N E 11 G V 40-Ok28?OOOfl.

[

.

.

,

.

Be:.ver Valley Power Stati:n, Unit No. I and No. 2

,

,

'

Integrated Inspection Report 50-334/97-08 and 50-412/97-08

-

Notice of Violation Response Page 2 DLC agrees with this finding, acknowledges that a misunderstanding of the issues associated with the violation occurred and appreciates the NRC's efforts to clarify these issues such that appropriate corrective actions can be taken.

'

Based on the above, DLC retracts its request to withdraw the violation, and in accordance with 10 CFR 2.201, provides the attached reply which addresses Violation B transmitted with the subject inspection report.

If there are any questions concerning this matter, please contact Mr. J. Arias at (412) 393-5203.

Sincerely, Sushil C. Jain c:

Mr. D. S. Brinkman, Sr. Project Manager

,

l Mr. D. M. Kern, Sr. Resident Inspector Mr. H. J. Miller, NRC Region I Administrator l

Mr. N. S. Perry, Acting Chief, Reactor Projects Branch No. 7, Region I Mr. J. R. White, Chief, Radiation Safety Branch, Region I /

i l

u_____

_ _ _ _ _ _. _

_

_ _ _.... _ _.. _

. _. _ _ _ _ _

,

- - _ _ _.- - - - -. - - - - - - - - - - - - - - - - - - -

--

- -- -

-

,

,

.

'.

DUQUESNE LIGHT COMPANY Nuclear Power Division Beaver Valley Power Station, Unit Nos. I and 2 Supplemental Repiv to Notice of Violation Integrated Inspection Report 50-334/97-08 and 50-412/97-08 Letter Dated November 26,1997 VIOLATION B (Severity Level IV, Supplement IV)

Description of Violation (50-334/97-08-05)

Unit 1 Technical Specification (TS) 6.8.1.a requires that, " Written procedures be established, implemented and maintained covering...the applicable procedures recommended in Appendix "A" of Regulatory Guide 1.33, Revision 2, February 1978,"

which includes procedures for radiation monitoring system (RMS) operation.

Contrary to the above, the licensee failed to establish adequate RMS calibration instructions in regard to determming RMS operating high voltage.

Specifically, operating high voltage was not established on a plateau for RM-lRM-215A (Unit 1 Containment Particulate) and RM-ILW-104 (Unit 1 Liquid Waste Effluent). This was contrary to vendor manual "Victoreen Installation, Operation, and Maintenance, Instmetion Manual Beta Scintillation Detectors Models 843-20,843-20A, and 843-20B" and "Victoreen Instructional Manual Gamma Scintillation Detector Model 843-30" respectively; and was contrary to RMS calibration standards and industry guidance documents.

Reason for the Violation The primary cause of this violation is that, while the method used to perform the radiation monitoring system (RMS) calibrations is technically correct, the procedures used to perform the calibration are inadequate in that they lack sufricient detail about the current calibration techniques and processes. The lack of detail resulted in, for some monitors, heavy reliance upon supervisory direction. An additional contributing factor was the use of a generic procedure for performance of plateau checks.

- _ - _ - -

.

.

,

.

Reply to Notice of Viol ti:n

,

NRC Integrated Inspection 50-334/97-08 and 50-412/97-08

'

Page 2 Corrective Actions Taken and the Results Achieved The following are the corrective actions taken:

A Condition Report was written and processed. As a result of Duquesne Light's

initial interpretation of the violation, the report evaluation, which included technical discussions with the RMS vendor, focused primarily on calibration method and not on implementing procedures and/or administrative control.

Bench testing of the effects of varying VAC line voltage on the RMS was

performed to ascertain if high voltage (HV) variations or shifts occurred with varying line voltage. Additionally, historical records of calibration as-found HV operating points were evaluated for indications of HV drift between calibrations.

Results of the testing and evaluation verified that the RMS voltage regulation circuits were very stable.

Self-assessments, extemal and internal, were conducted that evaluated the

calibration method and practices currently employed. These self-assessments concluded that the method used is technically correct; however, areas for improvement were identified.

The two radiation monitors cited in the inspection report were removed from

service and recalibrates to ensure the operating point for each was established within the vendor recommended operating range for detector HV. For RM-RM-215A, no changes to the existing operating point were necessary. For RM-LW-104, the suspect detector was replaced with a new detector yielding acceptable results, within the recommended HV operating range.

Additional testing was performed, at the request of the NRC effluents specialist,

of the suspect RM-LW-104 detector, in the installed system configuration. The results of this testing were provided to the NRC effluents specialist during an onsite discussion. Subsequent to this testing, the replacement detector from the previous action was reinstalled and calibrated and yielded an operating point within the recommended HV operating range.

. An onsite discussion was held between the NRC effluents specialist, Beaver Valley station personnel and RMS vendor representatives. The RMS tests results and assessments were made available and discussed. The result of the discussions was a determination that the method used to calibrate the RMS was technically correct but the procedures lacked sufficient detail regarding calibration techniques and processes.

w__

_ _ _ _ _

. _ _ _ _ _ _

.

.

,

e

,.

Reply to N tice cf Vi::lation NRC Integrated Inspection 50-334/97-08 and 50-412/97-08

Page 3 Corrective Actions to Prevent Further Violations

- The following additional corrective actions will be implemented:

A detailed discussion of RMS calibration techniques and processes, including the

maximum and minimum operating HV for each detector type, will be incorporated into appropriate implementing procedures.

An RMS specific procedure for performing plateau checks and determining the

HV operating point will be developed. The procedure will include selection of the calibration radionuclides (s), detennination of the HV plateau and increment range, and performance oflinear regression analyses of appropriate parameters.

Date When Full Compliance Will Be Achieved The procedure actions discussed above will be implemented by July 31,1998.

,

,

f

i