IR 05000331/1985019

From kanterella
Jump to navigation Jump to search
Addendum to Insp Rept 50-331/85-19 Comparing Analyses Performed on Spiked Liquid Samples Collected During Insp & Corrected Samples Submitted by Ref Lab
ML20202E765
Person / Time
Site: Duane Arnold 
Issue date: 04/07/1986
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
Shared Package
ML20202E747 List:
References
50-331-85-19, NUDOCS 8604140046
Download: ML20202E765 (1)


Text

.

.

o.

TABLE 1 U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT CONFIRMATORY MEASUREMENT! PROGRAM FACILITY: DAEC FOR THE THIRD QUARTER OF 1985 NRC LICENSEE LICENSEE:NRC SAMPLE ISOTOPE RESULT ERROR RESULT ERROR RATIO RES T

L WASTE H-3 1.8E-03 3.0E-05 1.7E-05 8.5E-06 9.7E-01 5.9E 01 A

SR-89 7.0E-09 6.0E-09 3.1E-09 0.0E-01 4.4E-01 1.2E 00 N

SR-90 0.0E-01 4.0E-09 1.6E-09 0.0E-01 0.0E-01 0.0E 01 N

GROSS B 9.0E-07.

4.0E-08 1.1E-06 1.2E-07 1.2E-00 2.3E 01 A

L SPIKED H-3 1.1E-04 2.0E-06 1.0E-04 2.1E-05 9.0E-01 5.7E 01 A

SR-90 5.2E-05 2.1E-06 5.3E-05 7.0E-06 1.0E-00 2.5E 01 A

SR-89 4.8E-04 1.4E-05 5.6E-04 4.2E-05 1.2E-00 3.4E 01 A

CS-137 2.4E-05 5.0E-07 2.2E-05 2.6E-06 9.5E-01 4.7E 01 A

CO-60 2.1E-05 4.0E-07 2.1E-05 3.4E-06 1.0E-00 5.3E 01 A

T TEST RESULTS:

A = AGREEMENT

,

D = DISAGREEMENT

  • = CRITERIA RELAXED N = NO COMPARISON

.

wou41*uu46 e60407

-

PDR AthDCK 05000331 i

G PDR f

. - -

-

-

-