IR 05000282/1988007

From kanterella
Jump to navigation Jump to search
Partially Withheld Physical Security Insp Repts 50-282/88-07 & 50-306/88-07 on 880523-27 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Security Plan & Implementing Procedures,Mgt Effectiveness,Testing & Maint & Locks & Keys
ML20195C090
Person / Time
Site: Prairie Island  
Issue date: 06/15/1988
From: Belanger J, Christoffer G, Funk D, Galanti D, Mallett B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20195C079 List:
References
50-282-88-07, 50-282-88-7, 50-306-88-07, 50-306-88-7, NUDOCS 8806220111
Download: ML20195C090 (2)


Text

...-.

._

.

.. - _ -

--.

--..,

'.

'

..

.

U. '. NUCLEAR REGULATORY COMMISSION

~

REGION III

Reports No. 50-282/88007(DRSS); 50-306/88007(DRSS)

Docket Nos. 50-282; 50-306 Licenses No. OPR-42; OPR-60 Licensee:

Northern States Power Company 414 Nicollet Mall Minneapolis, MN 55401 Facility Name:

Prairie Island Nuclear Generating Plant, Unit 1 and 2 Inspection At:

Prairie Island Site, Red Wing, Minnesota Inspection Conducted:

May 23-27, 1988 Type of Inspection:

Routine, Announced Physical Security Inspection Date of Previous Inspection:

May 11-15, 1987 Inspectors:

hSYOh b-\\6 kI D. E. Funk Jr.

Date Physical Security Inspector 4 C-Q A (,-t 5 4 8 G. M. Christoffer Date Physical Security Inspector S. R. Lg h (,- \\ 6 -N D. M. Galanti" Date Physical Security Inspector Reviewed By:

h-1.. h4Wp1

[o - /Y-87 J. L. Belanger, Ncting Chief Date Safegt.ard Section 0!/

II Approved By:

P C

r

.

Bruce S. Mal'lett/ Ph.D., Chi f Date Nuclect Materials Safety and

,

Safeguards Branch Enclosure contains SAFEGUARDS INFORMATI0'l Upon separation this page is Decontrolled 8806220111 880615 PDR ADOCK 05000282 Q

DCD

..

. -.

-

_

.

...

Inspection Summary Inspection on May 23-27, 1988 (Reports No. 50-282/88007(DRSS);

50-306/88007(DRSS))

Areas Inspected:

Included a review of Security Plar, and Implementing Procedures; Management Effectiveness; Testing and Maintenance; Locks, Keys and Combinations; Physical Barriers - Protected Areas; Physical Barriers - Vital Areas; Lighting; Compensatory Measures; Assessment Aids; Access Control -

Personnel; Access Control - Packages; Detection Aids - Protected Areas; Detection Aids - Vitil Area: Alarm Stations; Communications; Training and Qualifications - General Requirements; Protection of Safeguards Information; and Followup on Previous Inspection Findings.

Results:

The licensee was found to be in compliance with NRC requirements within the areas examined except as noted.

One violation was identified regarding the failure of the protected area intrusion detection system to detect attempted penetrations in several zones.

One RER concern and one open item dealing with SAS relocation remain open.

One open item concerning access control for personnel was identified.

(Details:

UNCLASSIFIED )

Enclosure contains SAFEGUARDS INFC:'J;\\TIOl[

Upon separation this page is Decontrolkd

.

.

,

..

.

_ _.

_ _ _ _ _ _ _ - -

--