i i

U. S. ATOMIC ENERGY COMMISSION

'

DIRECTORATE OF REGULATORY OPERATIONS

'

,

REGION III

RO Inquiry Report No. 050-263/72-17Q Ucrthern States Power Company 414 Nicollet Mall

Minneapolis, Minnesota $5401 Licence No. DPR-22 Monticello Nucidar Genera ing Plant RER Pump Motor.a11ureT)

Prepared Ey:

P'.E.'.io. son

'

" J i '

b d

j (Date)

A.

Date and Manner AEC was Informed:

Telephone call from Monticello Plant representative to RO:III on Decenber 18, 1972.

,

,

B.

Description of Particular Event or Circumstance:

The motor which drives one of the four Residual Heat Removal (RER)

purpo failed on December 16 during operation in the shutdown ecoling mode.. Initial investigation determined that the sheet metal air diffuser in the motor had failed from fatigue crackug originating near the anchor bolt holes. Fragments of the air diffuser cauced shorting of the motor vindings.

Inspection of the remaining RER cotors disclosed two additional air diffusers with' cracks initiated.

Severity of the cracks was proportional to the operating hours (177 to 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />) on the motors.

Pertinent information relating to the moter-la as follows:

Manufacturer:

General Electric Motor Description: Vertical, high thrust, polyphase, induction

+

4160 volt, 3560 RPM, 600 HP Frace No.:

6329PZ30 3erial No.:

SK6329EC4A Additional Identification No.: EDJ522005 C.

Action by Licensee:

A recctor startup was terminated for further investigation and ' repair.

An outage of several days is anticipated.

The licensee plans to report the matter to Licensing within 10 dayc.

9212030552 730103 PDR ADOCK 05000263;

'G'

PDR m

_