IR 05000263/1972002

From kanterella
Jump to navigation Jump to search
Investigation Rept 50-263/72-02.Noncompliance Noted.Major Areas Investigated:Licensee Failure to Detect Increase in Tank Level Coupled W/Decrease in Boric Acid Concentration
ML20024G535
Person / Time
Site: Monticello 
Issue date: 07/20/1972
From: Sniezek J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20024G522 List:
References
50-263-72-02, 50-263-72-2, NUDOCS 9102120621
Download: ML20024G535 (1)


Text

_ _ _

. - - - - - _ _.

_ _

. _ -. - -

--

- -

- -. _ - -. -... - - - -. - _ _ _ _ - _ - _

-.

.

,

.

U. S. ATOMIC ENERGY COMMISSION DIRECTORATE OF REGUIATORY OPERATIONS REC 10N III RO Inquiry Report No. 050-266/72-02 Subject: Wiscqnsin Michigan Power Company Licenso No. DPR-24 Point Beach Unit 1 Boric Acid Tank Concentration h o b...

e Prepared By:

/b J. H. Sniezek 1./, J.0 / f ff,

'

f/ 4Date)

,

A.

Date and Manner AEC was Informed:

Mr. Glenn A. Reed, Manager - Nuclear Power Division, notified Region'III by telephone on July 10, 1972.

B.

Description of Particular Event or Circumstance:

Boric acid tank A..was lined up to supply the charging pumps for Unit 1.

Analysis of the boron concentration in the A tank on July 18, 1572, indicated a coneontration of 11.0% boric acid by weight.

Technical Specification 15.3.2.B.3 requires that the boron concentra-tion be greater than 11.5% by weight. On July 11, 1972, the concentration in the A tank was determined to be 12.9% by weight and on July 14, 19 72, i t wa s 11. 8%.

The reactor wac operating et significant power.

C.

Action By Licensret l

The licensee sampled the B and C boric acid tanks and verified that the concentration was 12.9% by weight. The supply for Unit I was shifted to the B boric acid tank. The C tank was lined up to Unit 2 originally.

Mr. Reed stated that a review of the matter revealed that the makeup water supply valve to the A tank was cracked of f of its seat thos diluting the tank contents. A review of the facility records for the period July 11-18, 1972, indicated that the tank level increased from 40% to 52%.

.

The licensee intends to report this matter to the Directorate of Licensing within ten days as required by Technical Specification l

15.6.6.A.2.

l

-

.

9102120621 720622 gDR ADOCK 05000263 PDR

_. _

._ -

- _ -

___ _, _