April 10, 1998
SUBJECT:
NOTICE OF VIOLATION (NRC INSPECTION REPORT NO. 50-237/97021; 50-249/97021
Dear Mr. Kingsley:
This will acknowledge receipt of your letter dated April 6, 1998, in response to our letter dated March 6, 1998, transmitting three violations in a Notice of Violation associated with the failure to perform a written safety evaluation; the failure to update the Fire Protection Report; and the failure to review and revise the Fire Preplans. We have reviewed your corrective actions for the three violations and have no further questions at this time. These corrective actions will be examined during future inspections.
With regards to Unresolved Item URI 50-237/249-97021-01(DRS), where the team had concerns that the Updated Final Safety Analysis Report (UFSAR) did not accurately characterize the plant's design-basis or the plant's capability to respond to a potential Dresden Lock and Dam failure, this issue will be addressed in NRC Inspection Report 50-237/249/98007(DRS).
.
Docket Nos.: 50-237; 50-249
Sincerely, original /s/ J. A. Grobe John A. Grobe, Director Division of Reactor Safety Enclosure:
Ur dtd 4/6/98 from J. M. Heffley, ComEd to USNRC See Attached Distribution DOCUMENT NAME: G:DRS\\DRE04108.TY To receive a cop of this document, Indicate In the box: *c* =Cop withoul atlachmenVendosure *e* =Cop with atlachmenvendosure *w =No cop OFFICE Riii NAME Hausman:
DATE 9804160271 980410 PDR ADOCK 05000237 G
.
POR Riii l\\l Riii Riii 04/ /98 OFFICIAL RECORD COPY
- cc w/o encl:
M. Wallace, Senior Vice President D. Helwig, Senior Vice President G. Stanley, PWR Vice President J. Perry, BWR Vice President D. Farrar, Regulatory Services Manager I. Johnson, Licensing Director DCD - Licensing M. Heffley, Site Vice President P. Swafford, Station Manager F. Spangenberg, Regulatory Assurance Manager cc w/encl:
Richard Hubbard Distribution:
SAR (E-Mail)
Nathan Schloss, Economist Office of the Attorney General State Liaison Officer Chairman, Illinois Commerce Commission Project Mgr., NRR w/encl A Beach w/encl J. Caldwell w/encl B. Clayton w/encl SRI Dresden w/encl DRP w/encl TSS w/encl DRS w/encl Riii PRR w/encl PUBLIC IE-01 w/encl Docket File w/encl GREENS