U.S. NUCLEAR REGULATORY CCMMISSION

.

.

OFFICE OF INSPECTION AND ENFORCEMENT

,

.

,

Region I

'

Report No.

50-213/79-12 Safeguards Group:

Docket No.

50-213 License No. DPR-61 Priority Category C

Licensee:

Connecticut Yankee Atomic Power Company

.

P. O. Box 270 Hartford, Connecticut 06101

.

'

Facility Name:

Haddam Neck Plant

,

Inspection at:

Haddam Neck, Connecticut l

Inspection conducteT:

April 9-12, T979 l

Inspectors:

/

/%.

-

/

'/ /W R. J. Bailey, Physical Security Inspector

' da te' si gned ptch 7 - 2 ~ '? 9 i

. A

-

R. E. ShepheFd, Physical Security Inspector date signed date signed Approved by: [f/

VMwa e 8-/g, /pp

-

//,g. W. Devlin, Chjef, Secupity and Investigation J

~

date signed

..

Section, Safeguards Bra 6ch

,

I Inspection Summary:

Inspection on April 9-12, 1979 (Report No. 50-213/79-12)

Areas Inspected:

Routine, unannounced, Physical Protection inspection by regional-based inspectors of the implementation of the licensee's

,

accepted Security Plan and 10 CFR 73.70 relative to:

security program i

audit; security organization; physical barriers; lighting; access control; alarm stations; detection aids; assessment aids; communications; testing and maintenance; compensatory measures; power supply; response; locks, keys and combinations; records and reports.

The inspection started during off-shift hours and involved 71 inspector-hours onsite by two

'

,

NRC regional-based inspectors.

l Results: Of the fifteen areas inspected, no apparent items of noncompliance were identified in eleven areas.

Four apparent items of noncompliance were identified in four areas.

Physical Barriers (PA) Infraction -

Paragraph 5; Detection Aids, Infraction - Paragraph 10; Locks, Keys and Combinations, Ceficiency - Paragraph 17; Records and Reports, Deficiency -

Paragraph 18.

Region I Form 12 (Rev. April 77)

jjj7

7910090 7 69