j Florida Power A Progress Energy Company Crystal River Nuclear Plant Docket No. 50-302 Operating License No. DPR-72 Ref: 10CFR50.55a January 22, 2002 3F0102-04 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

Subject:

Crystal River Unit 3 Day Inservice Inspection (ISI) Summary Report

Dear Sir:

Florida Power Corporation (FPC) is providing the 90-Day Inservice Inspection (ISI) Summary Report as part of the attached American Society of Mechanical Engineers (ASME),Section XI, NIS-1, Owner's Report for Inservice Inspections.

The report is being submitted in accordance with the requirements of the 1989 Edition of the ASME Boiler and Pressure Vessel Code,Section XI, Article IWA-6000 with no Addenda.

This Summary Report addresses the ISI examinations and Repairs/Replacements from the conclusion of Refueling Outage 11, November 13, 1999, to the conclusion of Refueling Outage 12, October 25, 2001.

This letter establishes no new regulatory commitments.

If you have any questions regarding this submittal, please contact Mr. Sid Powell, Supervisor, Licensing and Regulatory Programs at (352) 563-4883.

Sincerely,

  • J~es H. Texý

"-4 ngineering Manager JHT/lvc

Attachment:

ASME,Section XI, NIS-1, Owner's Report for Inservice Inspections xc:

NRR Project Manager Regional Administrator, Region II Senior Resident Inspector 15760 West Power Line Street

  • Crystal River, Florida 34428-6708 * (352) 795-6486

ATTACHMENT ASME, SECTION XI, NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS 3F0102-04 COMMERCIAL SERVICE DATE - 03/13/1977 - Crystal River Unit 3 - 90 Day Inservice Inspection Summary Report Table of Contents Summary Report Abstract of Examinations, Tests, Results and Corrective Actions (10 Pages), Inservice Inspection Report (61 Pages), NIS-2 Owner's Reports of Repair or Replacement for ASME Class 1 and Class 2 Components (86 Pages)

NIS-1 Page 1 of 2 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

,\\

n..

IAA.1fl C, fl,.-,.L...,.

0 2222AflAO (Name and Address of Owner)

C"vtal River U nit 3 (CR-3) 15760 Power line Street Crystal River. FL. 34428-6708 (Name and Address of Plant)

3. Plant Unit Crystal River Unit 3 5.Commercial Service Date 3/13/1977
7. Components Inspected
4. Owner Certificate of Authorization (if required)

N/A

6. National Board Number for Unit N/A Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size in the same as this Data Report, (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbers and the number of sheets is recorded at the top of this form.
1. Owner Manufacturer or Installer Components or Manufacturer Serial No.

State or Provine National Board Appurtenance or Installer No.

No.

Reactor Vessel Babcock & Wilcox 620-0007-51-52 N/A N-i 17 Pressurizer Babcock & Wilcox 620-0007-59 N/A N-1 18 Steam Generator A Babcock & Wilcox 620-0007-55-1 N/A N-119 Steam Generator B Babcock & Wilcox 620-0007-55-2 N/A N-120 Various Piping, Pumps, N/A N/A N/A N/A Valves, Supports and Containment areas.

+

I I

I

.4.

4 1

1 4

4 t

1 4

4 t

1 4

4 t

I 4

4

+

4 4-I t

4 4-4 5

4-4 1-5 4-4

+

I

+

I t

Hlonia Power C~om'orauion, F.". Box St. 17tersoal urg

,. J_

J~*2 2:. Pl

NIS-1 Page 2 of 2 FORM NIS-1 (back)

8. Examination Dates:
9. Inspection Period Identification:

10 Inspection Interval Identification:

11 Applicable Edition of Section XI 12 Date/Revision of Inspection Plan:

11/13/99 to 10/25/2001 Period 1, 8/14/1998 to 12/13/2001 Interval 3, 8/14/1998 to 8/13/2008 1989 Addenda N/A 3/14/2000, Revision 3

13. Abstract of Examination and Tests. Include a list of examinations and a statement concerning status of work required for the inspection plan.

See Enclosure 1

14. Abstract of Results of Examinations and Tests.

See Enclosure 1

15. Abstract of Corrective Measures.

See Enclosure 1 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A r-.

Date 1/14/2002 Signed Florida Power Corporation Owner By Matthew F. Denn CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of fioIiDA and employed by 1458 LT" of IP-"1Th(Z i (rT have inspected the components described in this Owner's Data Report during the period 1L-l3-111 to I-H -O and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Data Report in accordance with the Inspection Plan and as required by the ASME code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examination and corrective measures described in this Owner's Data Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions FL Hq5 ( -1,,c, A )

National Board, State, Province, and No.

Inspector's Signature Date JA, iJ

.2002 CRYSTAL RIVER UNIT 3 90 DAY INSERVICE INSPECTION

SUMMARY

REPORT Table of Contents

  • , Inservice Inspection Report
  • , NIS-2 Owner's Reports of Repair or Replacement for ASME Class 1 and Class 2 Components

U.S. Nuclear Regulatory Commission Abstract 3F0102-04 Page I of 10 Summary Report Abstract of Examinations, Tests, Results and Corrective Actions INTRODUCTION:

The following report documents the American Society of Mechanical Engineers (ASME)

Section XI Code, Inservice Inspection (ISI) Examinations and Repairs/Replacements performed from the conclusion of Refuel Outage 11 (November 13, 1999) to the conclusion of Refuel Outage 12 (October 25, 2001). Refueling Outage 12 (RFO12) was the second outage for the Third Inspection Interval.

Examinations, Repairs and Replacements performed during this time period satisfy the requirements of the ASME Section XI Code, 1989 Edition, without Addenda.

Nuclear Regulatory Commission (NRC) regulations (10 CFR 50.55a) require that ISI examinations be performed in accordance with the latest edition and addenda of the ASME Code,Section XI, incorporated by reference, 12 months prior to the start of the 120-month interval. This report documents the examination activities conducted during this period. The detailed records of these examinations are on file and available at the plant site for review.

ASME Code Cases utilized by the Florida Power Corporation (FPC) during this period are documented within this report and have been approved for use either through inclusion in NRC Regulatory Guide 1.147, Revision 12 or by NRC approved Relief Requests.

EXAMINATIONS:

Components A summary listing of examinations conducted on ASME Class 1, 2, and 3 components is provided in Attachment 1. These examinations were conducted in accordance with the 1989 Edition without Addenda of the ASME Code,Section XI.

Steam Generator Eddy Current Examinations Eddy current examination was conducted on 100% of the tubes in-service in both steam generators during RFO 12. A separate summary report for these examinations is submitted to the NRC as required in Improved Technical Specification (ITS) 5.7.2.e.

This report documents these examinations as part of the NIS-1 report only.

Snubber Inspection Program The Crystal River Unit 3 (CR-3) Snubber Inspection Program implements examination/testing criteria based on the requirements of ASME Section XI, 1989 Edition, no Addenda and ASME/ANSI OM-1987, Part 4, 1988 Addenda.

U.S. Nuclear Regulatory Commission Abstract 3F0102-04 Page 2 of 10 The current CR-3 snubber population consists of 249 safety-relatedlsafety-significant snubber locations that require periodic visual examination, functional testing and service life monitoring/seal replacement. These locations are identified as accessible and inaccessible, but were considered as one population for inspection and testing during RFO112. Additionally, to help aid in Failure Mode Grouping and sample selection, all snubbers were identified in 3 separate populations - 186 small bore, 59 medium bore and 4 large bore snubbers.

For RFO 12 testing requirements, the initial 10% testing sample consisted of a combined total of 28 functional tests for the 3 populations (20 small bore, 7 medium bore and 1 large bore). For RFO 12 visual examination requirements, 100% as-found inspections were completed during the previous outage with no recorded failures, and therefore were not required this outage. Instead, as part of the service life program an augmented sample of 44 visual examinations (VT-3 as found and VT-3 as-left/pre-service) was performed on the replacement scope.

Upon completion of the RFO 12 work scope, functional testing of the initial sample detected no failures, and therefore no expansion of scope was required. Additionally, no visual failures were recorded during the augmented as-found examinations prior to snubber removal. Results of the functional tests and visual inspections are on file and available upon request and are summarized below.

U.S. Nuclear Regulatory Commission 3F0102-04 Abstract Page 3 of 10 eLineType Design Mark No Model Serial No Testing Scope Test Service Life Visual Resuls Scpe Rsults Safety Large Hyd RCH-614 PP 14X4.3 16676626 Augmented Sat Rebuild Sat Safety Large Hyd RCH-620 PP 14X4.3 16676627 Initial Sample Sat Rebuild Sat Line Type Design Mark No Model Serial No Testing Scope Testing Service Life Visual Scope Scope Results Safety Medium Hyd CFH-17 PP 4X5 720105 Initial Sample Sat Replace Sat Safety Medium Hyd FWH-128 PP 5X5 760068 Initial Sample Sat Replace Sat

...safety M.edium Hyd*

H, PP 4X5F 890002 Initial Sample Sat Replace Sat Safety Medium Hyd MSH-147 PP 5X5 720073 Initial Sample Sat Replace Sat Safety

'Medium Hyd MSH-167 PP 4X5 730117 Initial Sample Sat Replace Sat Safety Sig.

Medium Hyd MSH-238 PP 5X5 720069 Initial Sample Sat Replace Sat Safety Sig.

Medium Hyd MSH-145 PP 5X5 760067 Initial Sample Sat Replace Sat Line Type Design Mark No Model Serial No Testing Scope Testing Service Life Visual Scope Scope Results Safety Small Hyd BSH-1 5 PIP 2X5 720079 Initial Sample Sat Replace Sat PP 2X5 PP 2.5X5 PP 2.5X5 "PP 2.5X5 PP 1.5X5 PP 2.5X5 PP 2.5X5 PP 1.5X5 P P..S5 PP 1.5X5 PIP 1.5X5 PP 2.5X5 PP 2.5X5 PIP 2.5X15 PP 2.5X15 PP 2.5X10 PP 25 PIP 1.5X5 0 -P x.1..2

.X15 ITT 1.5X5 IPP 1.5X5 PP 1.5X5 PPi 1.5X5 PIP 1.5X5 J-PP 1.1SX1 k

PP 2.X5 PIP 2X5

_PP 1.5X5 PIP 1.5X5 jPP 1.5X 5 PIP 1.5X5 PIP 2X5 720113 720137 740046 730230 750130 730211 720139 730129 740003 750125 750132 730116 740080 790006688 750044 740088 730193 740011 760175 25589 730231 730150 720126 730222 760193 730228 750081 750085 7501 22 730131 730 113A1 760181 750120 Replace Initial Sample Sat Replace Initial Sample Sat Replace Initial Sample Sat Replace Replace Replace Initial Sample Sat Replace Replace Replace Replace Initial Sample Sat Replace Initial Sample Sat Replace initial Sample Sat Replace Replace Replace Replace Replace Initial Sample Sat Replace Initial Sample Sat Replace Initial Sample Sat Replace Replace Initial Sample Sat Replace Initial Sample Sat Replace Replace Initial Sample Sat Replace Initial Sample Sat Replace Replace initial Sa-mplei+ Sat Replace Replace Rep lac e

..................i................

Initial Sample Sat Replace Initial Sample Sat Replace Initial Sample.

Sat Replace Sat Sat Sat

.s.....

Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat

.S a t.......'

S..

.....S a t.......

Containment Inspection Progqram The CR-3 Containment Inspection Program implements an examination/testing schedule for ISI inspection of the primary containment pressure boundary in accordance with ASME Section XI, 1989 Edition, no Addenda and incorporates the requirements of the ASME Section XI, 1992 Addenda of Subsections IWE & IWL.

Safety Safety Safety Safety Safety Safety Safety Safety Safety "Safety Safety Safety Safety Safety Sig.

Safety Sig.

Safety Sig.

Safety Safety Safety

'Saf~et y§ Sig.

S Iafety Safety*

Safety Safety Safety Safety Safety Safety a.e!.+

Safety S...

+ e t.......

Safety Safety Safety Safety Small Hyd Small Hyd Small Hyd, Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hy d Small Hyd Small Hyd Small Hyd Small Hyd "Small HydI Smal1 Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd Small Hyd 1 BSR-35 CFH-1 3 CFH-14 CFH-1 8 DCR-33E DHH-17 DHH-1 9 DHH-39 DHR-24L DHR-24U EFH-109 EFH-27 F*VH-140 MSH-120 MSH-1 21 MSH-214 MSH-252 MSH-665 MUH-35 "MUH-39 MUH-41 MUH-42 MUH-43 MUH-45 RCH-60 RCH-64

-R

,C H-135" RCH-73 RCH-74 RCH-89

,+

U.S. Nuclear Regulatory Commission 3F0102-04 Abstract Page 4 of 10 For RFO12 IWL inspection requirements, the primary containment pressure boundary (concrete containment) was inspected and included 16 designated locations that make up the complete concrete containment. Each of these areas as listed below, was visually inspected utilizing the VT-3C visual method and further investigated with VT-iC for any suspect conditions.

Upon completion of the RFO12 work scope, visual inspection resulted in six of the 16 identified locations requiring additional VT-1C inspections. Upon completion of all VT-3C and VT-iC inspections, results were evaluated and dispositioned by the Responsible Professional Engineer (structural) as satisfactory and no further scope increases were conducted. Results of the visual inspections are on file and available upon request and are summarized below.

In addition to these visual examinations, the 2 5t' year (7 th) tendon surveillance was performed between the dates of 8/20/01 and 1/15/2002.

Due to the timing of the surveillance performance, the evaluation of the data has not been completed. The data will be evaluated and the results included in the summary report for Refueling Outage 13.

RBCN-001 Concrete Containment RBCN-002 Concrete Containment RBCN-003 Concrete Containment "RBcN-004 Concrete Containment R...Bc 0..

concrete Containment RBCN-006 Concrete Containment R*gcN-007 c*'oncret'e....

Containment RBCN-008 Concrete containment RBCN-009 IConcrete Containment R BcN01l 0 C oncrete Containment RcN-001 1.. Concrete Containment RBcN-o012 concrete Containment R4cN-0601 Concrete Containment R

N-

"1 concrete...

Containment RBCN-001 5 concrete Containment RBCN-0016 concrete Containment RBCN-00s3 Concrete Containment RBcN-000 c concrete L-A, L-.1i 1 300D to 45D 95' to 119' RB Visual, VT-3C Sat L-A, Ll.I 45D to 160D 95' to 119' RB Visual, VT-3C Sat L-A, L1.11 250D to 300D L-A, Li.*11 260D to 280D L-A, L1.11 L-A, LIii L-A, 1-1.11 L-A, L1.11 119' to 143' RB Visual, VT-3C Sat 119' to 129' RB Vis ual Sa 300D to 105D 119' to 143' RB Visual, VT-3C Sat 1400Dto 160D 118-4'to 146' RB Visual, VT-3C Sat 2050 to 300D 143' to 167' RB Visual, VT-3C 250D to 300D 162' to 200'-4" 180D to 2400.

119' to 267'6" 24001 D i to I 00 167' to 267'-6" L-A, Li

.11 3000 to 300D 149' to 267'-6"1I L-A, L1.11 L... L2i1.1i"1 00 to 60D 149' to 267'-6" 600 to 120 119' to267'-6"I L-A, L1.11 120D to 180D 119'to267'-6" L-A, L1.11 RB Visual, VT-3C RB I Visual, v-sc RB iVisual, wv-sc RB RB RB RB Visual, VT-3C Visual, V-sC Visual, VT-3C 0D to 30D0 Dome 267'-6" RB Visual, VT-3C 450 Do 1600.

9' t

o. 19' RB wv-ic.

Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat L-A, 1.12 180D to 240D 119' to 267'-6" RB VTF-1C Sat

U.S. Nuclear Regulatory Commission Abstract 3F0102-04 Page 5 of 10 Containment RBCN-001" 1 Concrete L-A, l.12 240D to 0D 1670to 267'-6" RB VT-i C Sat Containment CN012 C.....oncrete L...........3000.to...D*14' to k27-6" RB V.C.

Sat Containment i

RBCN-0013 Concrete L-A, L1.12

.Dto60D 149' to 267'-6" RB VT-C Sat Containment "RBCN-00143 Concrete LOAD L

i.12 600to 1200 119' to 267'-6" RB I.

VT-iC Sat Containm ent.

i RC-0014 Concrete L-A, L1.12 1200 to 120D 119' to 267'-6" RB VT-iC Sat Containment

.. - C o ntrain e nt i............-

5 o

o.

6............VT.

i S a RBCN-0016 Concrete L-A, L1.12 00 to 3000D oe26'6 RB VT-i C Sat Containment Pressure Testing There were two (2) Class 1, twenty-three (23) Class 2, and twenty (20) Class 3 system pressure tests conducted to meet the ASME Section XI Code requirements as amended by ASME Code Case N-498-1 during RFO12. These are documented in Attachment 1. Pressure testing for applicable Repairs/Replacements of ASME Class 1 and 2 components are documented on the applicable NIS-2 form attached to this report.

Repair and Replacement There were twenty-three (23) ASME Class 1 and twenty (20) ASME Class 2

Repairs/Replacements performed since the last summary report. A summary listing of these Repairs/Replacements is provided in Table 1 of this abstract. Additionally, the NIS-2 Owners Report of Repairs and Replacements documenting these Repairs/Replacements for ASME Class 1 and Class 2 components are included with this report as Attachment 2.

A ugmented Plan Examinations One (1) High-Pressure Injection (HPI) nozzle and associated piping up to the first isolation valve was examined by both ultrasonic and radiographic techniques.

These examinations were performed in accordance with Babcock & Wilcox Topical Report, "HPI/MU Nozzle Component Cracking."

Additionally, one visual examination was conducted on Inconel nozzles susceptible to intergranular attack.

There were no detrimental conditions identified during these examinations.

Visual examination of the 69 Control Rod Drive Mechanism Nozzles at their interface with the Reactor Pressure Vessel closure head were performed to detect signs of boric acid, which would indicate through-wall flaws.

There was one nozzle that had boric acid buildup indicative of a through-wall flaw. Ultrasonic examinations (UT) were performed on this nozzle to confirm the through-wall flaw. Eight additional UT exams were performed as an expansion.

The expansion exams revealed no similar flaws.

The flawed weld was mechanically removed and a new pressure boundary weld was installed. The pressure testing after the repair was performed satisfactorily.

U.S. Nuclear Regulatory Commission 3F0 102-04 Abstract Page 6 of 10 Two Reactor Coolant Pump Flywheels were ultrasonically examined to satisfy ITS requirements. These exams were conducted per the recommendations contained in Regulatory Guide 1.14, Positions 3, 4 and 5 of Section C.4.b. There were no detrimental conditions identified during these examinations.

CODE CASES and RELIEF REQUESTS:

This section documents all ASME Section XI Code Cases and NRC approved Relief Requests applicable to the reporting period.

Section XI Code Cases Used Code Case N-416-1, Code Case N-460, Code Case N-461, Code Case N-463-1, Code Case N-457, Code Case N-491-1, Code Case N-498-1, Code Case N-508-1, Code Case N-509, Code Case N-521, Code Case N-522, Code Case N-524, Alternative Rules for Hydrostatic Testing of Repair or Replacement of Class 2 Piping Section XI Division 1.

Alternative Examination Coverage for Class 1 and 2 Welds.

Alternative Rules for Piping Calibration Block Thickness.

Evaluation Procedures and Acceptance Criteria for Flaws in Class 1 Ferritic Piping That Exceed the Acceptance Standards of IWB-3514.2.

Qualification Specimen Notch Location for Ultrasonic Examination of Bolts and StudsSection XI, Division 1.

Alternative Rules for Examination of Class 1, 2, 3, and MC Components Supports of Light Water Cooled Power Plants.

Alternative Rules for 10 Year System Hydrostatic Testing for Class 1, 2, and 3 Systems.

Rotation of Serviced Snubbers and Pressure Relief Valves for the Purpose of Testing.

Alternative Rules for the Selection and Examination of Class 1, 2, and 3 Integrally Welded Attachments.

Alternative Rules for Deferral of Inspections of Nozzle-to Vessel Welds, Inside Radius Sections, and Nozzle-to Safe End Welds of a Pressurized Water Reactor (PWR) Vessel.

Pressure Testing of Containment Penetration Piping.

Alternative Examination Requirements for Longitudinal Welds in Class 1 and 2 Piping.

U.S. Nuclear Regulatory Commission 3F0102-04 Code Case N-533 Code Case N-546 Code Case N-598 Code Case N-638 Alternative Requirements for VT-2 Visual Examination of Class 1 Insulated Pressure-Retaining Bolted Connections.

Alternative Requirements for Qualification of VT-2 Examination Personnel.

Alternative Requirements to Required Percentages of Examinations.

Similar and Dissimilar Metal Welding Using Ambient Temperature Machine GTAW Temper Bead Technique.

Relief Requests 98-001-II Inside diameter Ultrasonic examination of the Core Flood Nozzles using enhanced UT as described in B&W Topical Reports BAW-2228-A and BAW-2228P.

98-002-II Surface Examination of Reactor Coolant Pump casing scroll welds. (RCP-lA only.)

98-003-11 Alternate examination criteria for the Reactor Vessel Support Skirt.

Perform limited VT-3 examination on 3 areas 1200 apart on the inside surface.

98-004-II Alternate examination criteria for Control Rod Drive Mechanisms (CRDM),

examination category B-O.

98-008-II Request to use the 1989 Addenda of ASME Section XI for examination category B-G-1 for the examination of reactor vessel closure nuts; Item B6.10.

98-009-II Request to use ASME Code Case N-598, Alternate Requirements to Required Percentages of Examinations.

98-010-IT Request to use ASME Code Case N-508-1, Rotation of Serviced Snubbers and Pressure Relief Valves for the Purpose of Testing.

98-012-1I Request for relief from performing the Code required VT-3 examination on metal containment seals and gaskets. (ASME Section XI, 1992 Edition) 98-013-II Request for relief from the provisions of Paragraph IWA-2300 in accordance with CP-189 as amended by ASME Section XI. (ASME Section XI, 1992 Edition) 98-014-I Request for relief from requirement to perform pre-service inspection of new paint or coatings.

98-015-II Request for relief from performing the Code required visual examination on paint or coatings prior to removal.

Abstract Page 7 of 10

U.S. Nuclear Regulatory Commission 3F0102-04 Abstract Page 8 of 10 98-016-Il Request for relief from performing the VT-2 visual examination in connection with system pressure testing following repair, replacement or modification under Article IWE-5000.

98-017-11 Request for relief from the requirement of Paragraphs IWE-2420(b) and IWE 2420(c) to perform successive examinations of repairs.

98-018-I1 Request for relief from performing bolt torque or tension tests on bolted connections that have not been disassembled and reassembled during the inspection interval.

00-002-II Request to use annual training requirements contained in 1 OCFR50.55a(b)(2)(xiv) in lieu of the requirements specified in Subarticle VII-4240 to Appendix VII of Section XI of the Code.

01-001-Il Request to use ASME Code Case N-623 for deferral of the 50% partial examination of the RPV shell-to-flange weld to the end of the inspection interval.

98-005-PT Request to use ASME Code Case N-533, Alternative Requirements for VT-2 Visual Examination of Class 1 Insulated Pressure-Retaining Bolted Connections.

98-001-SS Request to use the 1988 Addenda to the 1987 ASME OM Code for definition of Examination Interval, Subsequent Examination Schedule and Examination Sample Size.

01-002-RR Request to perform Reactor Pressure Vessel (RPV) Closure Head Control Rod Drive Mechanism (CRDM) nozzle penetration repairs with a remotely operated weld tool, utilizing the machine Gas Tungsten-Arc Welding (GTAW) process and the ambient temperature temper bead method with 50F minimum preheat temperature and no post weld heat.

01-003-RR Request to use worst case assumptions when evaluating flaws on Reactor Pressure Vessel (RPV) Closure Head Control Rod Drive Mechanism (CRDM) nozzle penetration welds.

U.S. Nuclear Regulatory Commission 3F0102-04 Abstract Page 9 of 10 The following NIS-2 forms are attached in compliance with the requirements of Article IWA-6220 of 1989 Edition of ASME Section XI without Addenda Class I NIS-2 Reports Work Description Repaired /

Request #

Replacement 365080 REPLACED RCV-8 BY BOLTING REPLACEMENT 366665 REPLACE CRDM'S BY BOLTING.

REPLACEMENT 366884 REPLACE VALVE BY BOLTING.

REPLACEMENT INSTALLED CANOPY SEAL ENCLOSURE TO VALVE DHV-3 BODY AND 366978 BONNET BY WELDING per MAR #P00080301.

REPLACEMENT 367235 REPLACE VALVE BY BOLTING.

REPLACEMENT 367328 REPLACED VALVES BY BOLTING.

REPLACEMENT REPLACED 2.5x5 POWER PIPING SNUBBER 720139 WITH LIKE-FOR-LIKE 368141 SNUBBER 720135.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 730147 WITH LIKE-FOR-LIKE 368146 SNUBBER 730014.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 7301 13A WITH LIKE-FOR-LIKE 368147 SNUBBER 750139.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 730131 WITH LIKE-FOR-LIKE 368148 SNUBBER 760200.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 750122 WITH LIKE-FOR-LIKE 368149 SNUBBER 760197.

REPLACEMENT REPLACED 1.5X5 POWER PIPING SNUBBER 730228 WITH LIKE FOR-LIKE 368154 SNUBBER 750125.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 760193 WITH LIKE-FOR-LIKE 368155 SNUBBER 750112.

REPLACEMENT REPLACED 1.5X5 POWER PIPING SNUBBER 730150 WITH LIKE FOR-LIKE 368156 SNUBBER 760194.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 730231 WITH LIKE-FOR-LIKE 368157 SNUBBER 740003.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 730129 WITH LIKE-FOR-LIKE 368177 SNUBBER 750104.

REPLACEMENT REPLACED 2.5"X5" POWER PIPING SNUBBER 730230 WITH LIKE-FOR-LIKE 368178 SNUBBER 720083.

REPLACEMENT REPLACED 4"X5" POWER PIPING SNUBBER 720105 WITH LIKE-FOR-LIKE 368179 SNUBBER 730018.

REPLACEMENT REPLACED 2.5"X5" POWER PIPING SNUBBER 740046 WITH LIKE-FOR-LIKE 368180 SNUBBER 740047.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 720125 WITH LIKE-FOR-LIKE 368415 SNUBBER 720132.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 730222 WITH LIKE-FOR-LIKE 368427 SNUBBER 730140.

REPLACEMENT

U.S. Nuclear Regulatory Commission 3F0102-04 Abstract Page 10 of 10 rnnnAfl NAflflTCV C*Ifl'M Y'l,7T71 g' 19 fly WFIT flING PER MAR 01-09-02-01.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 750100 WITH LIKE-FOR-LIKE 371706 SNUBBER 750132..

REPLACEMENT Class 2 NIS-2 Reports Work Description Repaired /

Request #

Replacement 357800 REPAIR SUPPORTS BY WELDING.

REPAIRED 363265 REPLACED MISSING BOLTS.

REPLACEMENT 367039 REPLACED SUPPORT CLAMP BOLT.

REPLACEMENT 367605 REPLACE VALVE INTERNALS.

REPLACEMENT REPLACED 1.5"X5" POWER PIPING SNUBBER 750120 WITH LIKE-FOR-LIKE 368144 SNUBBER 760199.

REPLACEMENT REPLACED 2X5 POWER PIPING SNUBBER 760175 WITH LIKE FOR-LIKE 368159 SNUBBER 730039.

REPLACEMENT REPLACED 4"X5" POWER PIPING SNUBBER 730117 WITH LIKE-FOR-LIKE 368164 SNUBBER 740036.

REPLACEMENT REPLACED 5"X5" POWER PIPING SNUBBER 720073 WITH LIKE-FOR-LIKE 368165 SNUBBER 720075.

REPLACEMENT REPLACED 2.5"X5" POWER PIPING SNUBBER 740080 WITH LIKE-FOR-LIKE 368171 SNUBBER 740092.

REPLACEMENT REPLACED 5X5 POWER PIPING SNUBBER 760068 WITH LIKE-FOR-LIKE 368172 SNUBBER 760036..

REPLACEMENT REPLACED 2.5X5 POWER PIPING SNUBBER 730116 WITH LIKE FOR-LIKE 368173 SNUBBER 730217.

REPLACEMENT REMOVED SNUBBER S/N 750125 FROM LOCATION DHR-24U AND REPLACED 368175 WITH LIKE-FOR-LIKE SNUBBER S/N 750134.

REPLACEMENT REMOVED SNUBBER S/N 740003 FROM LOCATION DHR-24L AND REPLACED 368176 WITH LIKE-FOR-LIKE SNUBBER S/N 730128.

REPLACEMENT REPLACED 2.5X5 POWER PIPING SNUBBER 720137 WITH LIKE FOR-LIKE 368181 SNUBBER 720138.

REPLACEMENT 368182 REPLACED SNUBBER 720113 WITH LIKE FOR LIKE SNUBBER 750073.

REPLACEMENT REPLACED 2"X5" POWER PIPING SNUBBER 720079 WITH LIKE-FOR-LIKE 368183 SNUBBER 730114.

REPLACEMENT REPLACED 4X5 POWER PIPING SNUBBER 890002 WITH LIKE FOR-LIKE 368200 SNUBBER 760071.

REPLACEMENT REPLACED 2.5"X5" POWER PIPING SNUBBER 730211 WITH LIKE-FOR-LIKE 368411 SNUBBER 720136.

REPLACEMENT 368807 REPLACED VALVE BY BOLTING REPLACEMENT REMOVED AND RE-WELDED 2.5" SW LINES AND PIPE SUPPORT MU HGR TYP 371012 25 IN SUPPORT OF RCP-IB SW-COOLER WORK.

REPLACEMENT

ASME, SECTION XI, NIS-1 ATTACHMENT 1 Inservice Inspection Summary Report (61 Pages)

Florida Power A Progress Energy 1orr ;ýn,,,n Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-A ITEM: B1.40 Summary No.

B1.3.2A Component ID RCRE-1 Workscope Report No.

Exam Results ISI UT-01-129 Sat Component Description REACTOR VESSEL FLANGE-TO-HEAD WELD MK24-TO-22 Work Request No.

Examination Rem*

366472 1/3 of Weld Lengtl System

System Description

RC REACTOR COOLANT arks h Examined - Access limited from one side.

CATEGORY: B-B ITEM: B2.40 Summary No.

Component ID Component Description System

System Description

B3.1.2A RCSG-1A OTSG TUBESHEET-TO-HEAD WELD MK7-RC REACTOR COOLANT TO-50 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-128 Sat 366464 CATEGORY: B-D ITEM: B3.110 Summary No.

Component ID Component Description System

System Description

B2.2.3A RCT-1 PRESSURIZER MK31-TO-5 Z-W AXIS RC REACTOR COOLANT NOZZLE-TO-HEAD Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-032 Sat 366464 Limited examination due to component configuration.

ITEM: B3.120 Component Description PRESSURIZER MK31-TO-5 Z-W AXIS NOZZLE INNER RADIUS System

System Description

RC REACTOR COOLANT Workscope Report No.

Exam Results ISI UT-01-033 Sat Work Request No.

366464 Examination Remarks Limited examination due to component configuration.

ITEM: B3.130 Component Description OTSG MK65-7 Z-W AXIS NOZZLE-TO HEAD System

System Description

RC REACTOR COOLANT Workscope Report No.

ISl UT-01-123 Exam Results Work Request No.

Sat 366464 Examination Remarks Limited examination due to component configuration.

ITEM. B3.140 Component Description OTSG Z-W AXIS VESSEL NOZZLE INNER RADIUS System

System Description

RC REACTOR COOLANT Workscope Report No.

ISI UT-01-124 Exam Results Sat Work Request No.

366464 Examination Remarks Limited examination due to component configuration.

Wednesday, January 16, 2002 CLASS:

1 Summary No.

B2.2.3B Component ID RCT-1 Summary No.

B3.2.3 Component ID RCSG-1A Summary No.

B3.2.3.1 Component ID RCSG-1A PagelI of 61

SFlorida Power A Progress Energy C(orn-,any CLASS:

1 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #1 Report No.

VT-01-002 VT-01-105 Exam Results Sat Sat Component Description CRDM Head Penetration H-8 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.02 CRDM Nozzle #2 CRDM Head Penetration G-7 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01 -003 Sat 368781 As-Found VT-2 Examination AUG VT-01 -106 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.03 CRDM Nozzle #3 CRDM Head Penetration G-9 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-004 Sat 368781 As-Found VT-2 Examination AUG VT-01-107 Sat 368781 VT-2 Following Head Cleaning Component I D CRDM Nozzle #4 Report No.

VT-01 -005 VT-01-108 Exam Results Sat Sat Component ID CRDM Nozzle #5 Report No.

VT-01-006 VT-01-109 Exam Results Sat Sat Component ID CRDM Nozzle #6 Report No.

Exam Results VT-01-007 Sat VT-01-110 Sat n

on K-9 Component Descriptior CRDM Head Penetratir Work Request No.

368781 368781 Component Descriptior CRDM Head Penetratic Work Request No.

368781 368781 Component Description CRDM Head Penetration F-8 Work Request No.

Exami 368781 As-Fo 368781 VT-2 t

System A

escrpCon RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning SSystem

System Description

on K-7 RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning System

System Description

RC REACTOR COOLANT nation Remarks und VT-2 Examination Following Head Cleaning Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

B11.5.1.01 Workscope AUG AUG Summary No.

B1.5.1.04 Workscope AUG AUG Summary No.

B1.5.1.05 Workscope AUG AUG Summary No.

B1.5.1.06 Workscope AUG AUG Page 2 of 61

Florida Power Ak Progress Energy Comprrln Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #7

10.

Exam Results 08 Sat 11 Sat Component Description CRDM Head Penetration H-10 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component I D Component Description System

System Description

B1.5.1.08 CRDM Nozzle #8 CRDM Head Penetration L-8 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VE-01-019 Eval 368781 Non-Relevant UT Fabrication Indications - Acceptable AUG VT-01 -009 Sat 368781 As-Found VT-2 Examination AUG VT-01 -112 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.09 CRDM Nozzle #9 CRDM Head Penetration H-6 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-010 Sat 368781 As-Found VT-2 Examination AUG VT-01-113 Sat 368781 VT-2 Following Head Cleaning Component I D CRDM Nozzle #10 Report No.

VT-01 -011 VT-01l-114 Exam Results Sat Sat Component ID CRDM Nozzle #11 0o.

Exam Results 12 Sat 15 Sat Component ID CRDM Nozzle #12

01.

Exam Results 13 Sat 16 Sat Component Description CRDM Head Penetration F-6 Work Request No.

368781 368781 Sst System A

escnrptCon RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Component Description CRDM Head Penetration F-10 System

System Description

RC REACTOR COOLANT Work Request No.

Examination Remarks 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Component Description System

System Description

CRDM Head Penetration L-1 0 RC REACTOR COOLANT Work Request No.

Examination Remarks 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Wednesday, January 16, 2002 CLASS:

1 Summary No.

B13.5.1.07 Workscope AUG AUG Report N VT-0l-0(

VT-01-1 Summary No.

B11.5.1.10 Workscope AUG AUG Summary No.

B1.5.1.11 Workscope AUG AUG Summary No.

B11.5.1.12 Workscope AUG AUG Report N VT-01-0 VT-01-1 Report N VT-01-0 VT-01 -1 Page 3 of 61

S Florida Power A Progress Energy Conrpany Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #13 Report No.

VT-01-014 VT-01 -117 Exam Results Sat Sat Component Description CRDM Head Penetration L-6 Work Request No.

Exami 368781 As-Fo 368781 VT-2 System

System Description

RC REACTOR COOLANT ination Remarks und VT-2 Examination Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.14 CRDM Nozzle #14 CRDM Head Penetration E-7 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-015 Sat 368781 As-Found VT-2 Examination AUG VT-01-118 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.15 CRDM Nozzle #15 CRDM Head Penetration E-9 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01 -016 Sat 368781 As-Found VT-2 Examination AUG VT-01 -119 Sat 368781 VT-2 Following Head Cleaning Component ID CRDM Nozzle #16 Report No.

VT-01-017 VT-01-120 Exam Results Sat Sat Component ID CRDM Nozzle #17 Report No.

VT-01 -018 VT-01 -121 Exam Results Sat Sat Component ID CRDM Nozzle #18 Report No.

VT-01-019 VT-01-122 Exam Results Sat Sat Component Descriptior CRDM Head Penetrati Work Request No.

368781 368781 Component Descriptior CRDM Head Penetratic Work Request No.

368781 368781 Component Description CRDM Head Penetration M-9 Work Request No.

368781 368781 n

on G-11 S

rysem A

escrCpLon RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning n

System

System Description

on K-11 RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Wednesday, January 16, 2002 CLASS:

1 Summary No.

B1.5.1.13 Workscope AUG AUG Summary No.

B1.5.1.16 Workscope AUG AUG Summary No.

B11.5.1.17 Workscope AUG AUG Summary No.

B1.5.1.18 Workscope AUG AUG Page 4 of 61

Florida Power A Progress Energy Corrimany Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #19 Report No.

VT-01 -020 VT-01-123 Exam Results Sat Sat Component Description CRDM Head Penetration M-7 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.20 CRDM Nozzle #20 CRDM Head Penetration K-5 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-021 Sat 368781 As-Found VT-2 Examination AUG VT-01-124 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.21 CRDM Nozzle #21 CRDM Head Penetration G-5 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VE-01-020 Eval 368781 Non-Relevant UT Fabrication Indications - Acceptable AUG VT-01-022 Sat 368781 As-Found VT-2 Examination AUG VT-01-125 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.22 CRDM Nozzle #22 CRDM Head Penetration D-8 RC REACTOR COOLANT Report No.

VT-01-023 VT-01-126 Exam Results Sat Sat Component ID CRDM Nozzle #23 Report No.

Exam Results VT-01 -024 Sat VT-01-127 Sat Component I D CRDM Nozzle #24 Report No.

VT-01-025 VT-01-128 Exam Results Sat Sat Work Request No.

368781 368781 Component Descriptio CRDM Head Penetrati Work Request No.

368781 368781 Component Descriptio CRDM Head Penetrati Work Request No.

368781 368781 Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning n

on H-12 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning n

System

System Description

on N-8 RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Wednesday, January 16, 2002 CLASS:

1 Summary No.

B1.5.1.19 Workscope AUG AUG Workscope AUG AUG Summary No.

B1.5.1.23 Workscope AUG AUG Summary No.

B1.5.1.24 Workscope AUG AUG Page 5 of 61

Florida Power A Progress Energy Co myn Inservice Inspection Report Interval 3 / Period 1 1 Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #25 Report No.

VT-01-026 VT-01-129 Exam Results Sat Sat Component Description CRDM Head Penetration H-4 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.26 CRDM Nozzle #26 CRDM Head Penetration E-5 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-027 Sat 368781 As-Found VT-2 Examination AUG VT-01-130 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.27 CRDM Nozzle #27 CRDM Head Penetration E-1 1 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-028 Sat 368781 As-Found VT-2 Examination AUG VT-01-131 Sat 368781 VT-2 Following Head Cleaning Component ID CRDM Nozzle #28 Report No.

Exam Results VT-01 -029 Sat VT-01 -132 Sat Component ID CRDM Nozzle #29 Report No.

Exam Results VT-01-030 Sat VT-01-133 Sat Component ID CRDM Nozzle #30 Report No.

VT-01-031 VT-01-134 Exam Results Sat Sat Component Description CRDM Head Penetration M-1 1 Work Request No.

368781 368781 Sy Rystem DescOption RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Component Description CRDM Head Penetration M-5 Work Reauest No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Component Description CRDM Head Penetration D-6 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Wednesday, January 16, 2002 CLASS:

1 Summary No.

B13.5.1.25 Workscope AUG AUG Summary No.

B13.5.1.28 Workscope AUG AUG Summary No.

B13.5.1.29 Workscope AUG AUG Summary No.

B1.5.1.30 Workscope AUG AUG Page 6 of 61

Florida Power A Progress Energy Com-an' Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component I D CRDM Nozzle #31 Report No.

VT-01-032 VT-01-135 Exam Results Sat Sat Component Description CRDM Head Penetration D-1 0 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.32 CRDM Nozzle #32 CRDM Head Penetration F-12 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VE-01-021 Unsat 368781 Unacceptable UT Indications - Nozzle was replaced by welding.

AUG VT-01-033 Unsat 368781 As-Found VT-2 Examination - Nozzle was replaced by welding.

AUG VT-01-136 Unsat 368781 VT-2 Following Head Cleaning - Nozzle was replaced by welding.

Summary No.

Component ID Component Description System

System Description

B1.5.1.33 CRDM Nozzle #33 CRDM Head Penetration L-12 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-034 Sat 368781 As-Found VT-2 Examination AUG VT-01-137 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

CRDM Nozzle #34 Report No.

VT-01-035 VT-01-138 Exam Results Sat Sat Component ID CRDM Nozzle #35 Report No.

Exam Results VT-01 -036 Sat VT-01-139 Sat Component ID CRDM Nozzle #36 Report No.

VT-01-037 VT-01-140 CRDM Head Penetration N-1 0 RC REACTOR COOLANT Work Request No.

Examination Remarks 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Component Description CRDM Head Penetration N-6 Work Request No.

Exami 368781 As-Foi 368781 VT-2 F Component Description CRDM Head Penetration L-4 Exam Results Work Request No.

Sat 368781 Sat 368781 System

System Description

RC REACTOR COOLANT nation Remarks und VT-2 Examination Following Head Cleaning System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Wednesday, January 16, 2002 CLASS:

1 Summary No.

B1i.5.1.31 Workscope AUG AUG B13.5.1.34 Workscope AUG AUG Summary No.

B1.5.1.35 Workscope AUG AUG Summary No.

B1.5.1.36 Workscope AUG AUG Page 7 of 61

Florida Power A Progress Energy Cinmsn',

Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #37 Report No.

VT-01 -038 VT-01-141 Exam Results Sat Sat Component Description CRDM Head Penetration F-4 Work Request No.

Exami 368781 As-Fo 368781 VT-2 System

System Description

RC REACTOR COOLANT nation Remarks und VT-2 Examination Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.38 CRDM Nozzle #38 CRDM Head Penetration C-7 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-039 Sat 368781 As-Found VT-2 Examination AUG VT-01-142 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.39 CRDM Nozzle #39 CRDM Head Penetration C-9 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-040 Sat 368781 As-Found VT-2 Examination AUG VT-01-143 Sat 368781 VT-2 Following Head Cleaning Component ID CRDM Nozzle #40 Report No.

VE-01-022 VT-01 -041 VT-01-144 Exam Results Sat Sat Sat Component I D CRDM Nozzle #41 Report No.

VT-01-042 VT-01-145 Exam Results Sat Sat Component ID CRDM Nozzle #42 Report No.

VT-01-043 VT-01-146 Exam Results Sat Sat Component Descriptio CRDM Head Penetrati Work Reauest No.

368781 368781 368781 Component Descriptio CRDM Head Penetrati Work Request No.

368781 368781 Component Descriptio CRDM Head Penetrati Work Request No.

368781 368781 n

on G-13 ystem RETescripOOLAn RC REACTOR COOLANT Examination Remarks UT Examination As-Found VT-2 Examination VT-2 Following Head Cleaning n

System

System Description

on K-13 RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning n

System

System Description

on 0-9 RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Wednesday, January 16, 2002 CLASS:

1 Summary No.

B1.5.1.37 Workscope AUG AUG Summary No.

B13.5.1.40 Workscope AUG AUG AUG Summary No.

B13.5.1.41 Workscope AUG AUG Summary No.

B13.5.1.42 Workscope AUG AUG Page 8 of 61

Florida Power A Progress Energy Corr-,ny Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #43 Report No.

VT-01-044 VT-01-147 Exam Results Sat Sat Component Description CRDM Head Penetration 0-7 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.44 CRDM Nozzle #44 CRDM Head Penetration K-3 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-045 Sat 368781 As-Found VT-2 Examination AUG VT-01-148 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B13.5.1.45 CRDM Nozzle #45 CRDM Head Penetration G-3 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01 -046 Sat 368781 As-Found VT-2 Examination AUG VT-01-149 Sat 368781 VT-2 Following Head Cleaning Report N VT-01-0.

VT-01-1E Report N VT-01 -0 VT-01-1 Report N VT-01-0 VT-01-1 Component ID CRDM Nozzle #46 0o.

Exam Results 47 Sat 50 Sat Component ID CRDM Nozzle #47 0o.

Exam Results 48 Sat 51 Sat Component ID CRDM Nozzle #48 No.

Exam Results 49 Sat 52 Sat Component Description CRDM Head Penetration D-4 System

System Description

RC REACTOR COOLANT Work Request No.

Examination Remarks 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Component Description System

System Description

CRDM Head Penetration D-12 RC REACTOR COOLANT Work Request No.

Examination Remarks 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Component Description System

System Description

CRDM Head Penetration N-12 RC REACTOR COOLANT Work Request No.

Examination Remarks 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Wednesday, January 16, 2002 CLASS:

1 Summary No.

B13.5.1.43 Workscope AUG AUG Summary No.

B13.5.1.46 Workscope AUG AUG Summary No.

B1.5.1.47 Workscope AUG AUG Summary No.

B13.5.1.48 Workscope AUG AUG Page 9 of 61

Florida Power A Progress Energy Chmnar,'

Inservice Inspection Report Interval 3 1 Period 1 / Refuel Cycle 12 CLASS:

1 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #49 Report No.

VT-01-050 VT-01-153 Exam Results Sat Sat Component Description CRDM Head Penetration N-4 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.50 CRDM Nozzle #50 CRDM Head Penetration C-5 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01 -051 Sat 368781 As-Found VT-2 Examination AUG VT-01-154 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B13.5.1.51 CRDM Nozzle #51 CRDM Head Penetration C-11 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-052 Sat 368781 As-Found VT-2 Examination AUG VT-01-155 Sat 368781 VT-2 Following Head Cleaning Component ID CRDM Nozzle #52 Report No.

VE-01-023 VT-01-053 VT-01-156 Exam Results Sat Sat Sat Component ID CRDM Nozzle #53 Report N VT-01 -05 VT-01-1E Report No.

VE-01-024 VT-01-055 VT-01-158

01.

Exam Results 54 Sat 57 Sat Component I D CRDM Nozzle #54 Exam Results Eval Sat Sat Component Descriptior CRDM Head Penetrati Work Request No.

368781 368781 368781 Component Descriptioi CRDM Head Penetrati Work Request No.

368781 368781 Component Description CRDM Head Penetration 0-11 Work Request No.

368781 368781 368781 S

E ASCTm uescnpTon RC REACTOR COOLANT n

on E-13 Examination Remarks UT Examination As-Found VT-2 Examination VT-2 Following Head Cleaning n

System

System Description

on M-13 RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning System

System Description

RC REACTOR COOLANT Examination Remarks Non-Relevant UT Fabrication Indications - Acceptable As-Found VT-2 Examination VT-2 Following Head Cleaning Wednesday, January 16, 2002 Summary No.

B13.5.1.49 Workscope AUG AUG Summary No.

B13.5.1.52 Workscope AUG AUG AUG Summary No.

B13.5.1.53 Workscope AUG AUG Summary No.

B1.5.1.54 Workscope AUG AUG AUG Page 10 of 61

S Florida Power A Progress Energy r*omnw,-

CLASS:

1 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #55 Report No.

VT-01-056 VT-01-159 Exam Results Sat Sat Component Description CRDM Head Penetration 0-5 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.56 CRDM Nozzle #56 CRDM Head Penetration M-3 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-057 Sat 368781 As-Found VT-2 Examination AUG VT-01 -160 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component I D Component Description System

System Description

B13.5.1.57 CRDM Nozzle #57 CRDM Head Penetration E-3 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-058 Sat 368781 As-Found VT-2 Examination AUG VT-01-161 Sat 368781 VT-2 Following Head Cleaning Component ID CRDM Nozzle #58 Report No.

VE-01-025 VT-01 -059 VT-01 -162 Exam Results Eval Sat Sat Component ID CRDM Nozzle #59 Report No.

Exam Results VT-01-060 Sat VT-01-163 Sat Component ID CRDM Nozzle #60 Report No.

Exam Results VT-01 -061 Sat VT-01-164 Sat Component Description CRDM Head Penetration B-8 System System Desciption RC REACTOR COOLANT Work Request No.

Examination Remarks 368781 Non-Relevant UT Fabrication Indications - Acceptable 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Component Description System

System Description

CRDM Head Penetration H-14 RC REACTOR COOLANT Work Request No.

Examination Remarks 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Component Description CRDM Head Penetration P-8 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 1 Refuel Cycle 12 Summary No.

B1.5.1.55 Workscope AUG AUG Summary No.

B13.5.1.58 Workscope AUG AUG AUG Summary No.

B1.5.1.59 Workscope AUG AUG Summary No.

B1.5.1.60 Workscope AUG AUG Page 11 of 61

Florida Power A Progress Energy ComaiWy Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component ID CRDM Nozzle #61 Report No.

VT-01-062 VT-01-165 Exam Results Sat Sat

-Component Description CRDM Head Penetration H-2 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.62 CRDM Nozzle #62 CRDM Head Penetration B-6 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01 -063 Sat 368781 As-Found VT-2 Examination AUG VT-01 -166 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.63 CRDM Nozzle #63 CRDM Head Penetration B-10 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VE-01-026 Eval 368781 Non-Relevant UT Fabrication Indications - Acceptable AUG VT-01-064 Sat 368781 As-Found VT-2 Examination AUG VT-01-167 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B13.5.1.64 CRDM Nozzle #64 CRDM Head Penetration F-14 RC REACTOR COOLANT Report No.

Exam Results VE-01 -027 Sat VT-01-065 Sat VT-01-168 Sat Component ID CRDM Nozzle #65 Work Request No.

368781 368781 368781 Examination Remarks UT Examination As-Found VT-2 Examination VT-2 Following Head Cleaning Component Description CRDM Head Penetration L-14 System

System Description

RC REACTOR COOLANT Report No.

VT-01 -066 VT-01 -169 Exam Results Sat Sat Component ID CRDM Nozzle #66 Report No.

VT-01-067 VT-01-170 Exam Results Sat Sat Work Request No.

Examination Remarks 368781 As-Found VT-2 Examination 368781 VT-2 Following Head Cleaning Component Description System

System Description

CRDM Head Penetration P-10 RC REACTOR COOLANT Work Reauest No.

368781 368781 Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Wednesday, January 16, 2002 CLASS:

1 Summary No.

B1.5.1.61 Workscope AUG AUG Workscope AUG AUG AUG Summary No.

B1.5.1.65 Workscope AUG AUG Summary No.

B1.5.1.66 Workscope AUG AUG Page 12 of 61

Florida Power A Progress Energy Com?,any Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-E ITEM: B4.12 Component I D CRDM Nozzle #67 Report No.

VT-01 -068 VT-01-171 Exam Results Sat Sat Component Description CRDM Head Penetration P-6 Work Request No.

368781 368781 System

System Description

RC REACTOR COOLANT Examination Remarks As-Found VT-2 Examination VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.68 CRDM Nozzle #68 CRDM Head Penetration L-2 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-069 Sat 368781 As-Found VT-2 Examination AUG VT-01-172 Sat 368781 VT-2 Following Head Cleaning Summary No.

Component ID Component Description System

System Description

B1.5.1.69 CRDM Nozzle #69 CRDM Head Penetration F-2 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG VT-01-070 Sat 368781 As-Found VT-2 Examination AUG VT-01-173 Sat 368781 VT-2 Following Head Cleaning CATEGORY: B-G-1 ITEM: B6.10 Summary No.

B1.8.4.00 Component ID RCRE-1 Workscope Report No.

Exam Results ISl VT-01-196 Sat Summary No.

Component ID B1.8.4.01 RCRE-1 Workscope Report No.

ISI VT-01-197 Summary No.

B1.8.4.02 Workscope ISI Summary No.

B1.8.4.03 Exam Results Sat Component ID RCRE-1 Report No.

Exam Results VT-01-198 Sat Component ID RCRE-1 Workscope Report No.

Exam Results ISI VT-01-199 Sat Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-1 Work Request No.

Examination Remarks 366474 Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-2 Work Request No.

Examination Remarks 366474 Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-3 Work Request No.

Examination Remarks 366474 Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-4 Work Request No.

Examination Remarks 366474 System RC System RC System RC System RC Wednesday, January 16, 2002 CLASS:

1 Summary No.

B13.5.1.67 Workscope AUG AUG

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT Page 13 of 61

SFlorida Pow er Ar Progress Energy Cam*any Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-G-1 ITEM: B6.10 Summary No.

B1.8.4.04 Workscope Report ISI VT-01-2 Component ID RCRE-1 Lo.

Exam Results 00 Sat Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-5 Work Request No.

Examination Remarks 366474 Syster RC

System Description

REACTOR COOLANT Summary No.

Component ID Component Description System

System Description

B1.8.4.05 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT RC REACTOR COOLANT 26-207-6 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-201 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.8.4.06 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT RC REACTOR COOLANT 26-207-7 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -202 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.8.4.07 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT RC REACTOR COOLANT 26-207-8 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-203 Sat 366474 Summary No.

B1.8.4.08 Component ID RCRE-1 Workscope Report No.

ISI VT-01 -204 Summary No.

B1.8.4.09 Exam Results Sat Component ID RCRE-1 Workscope Report No.

ISI VT-01-205 Summary No.

B1.8.4.10 Exam Results Sat Component ID RCRE-1 Workscope Report No.

Exam Results ISI VT-01-206 Sat Summary No.

Component ID B1.8.4.11 RCRE-1 Workscope Report No.

ISI VT-01-207 Exam Results Sat Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-9 Work Request No.

Examination Remarks 366474 Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-10 Work Request No.

Examination Remarks 366474 Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-11 Work Request No.

Examination Remarks 366474 Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-12 Work Request No.

Examination Remarks 366474 t

Rystem A

escrCpton RC REACTOR COOLANT System RC System RC System RC

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT Wednesday, January 16, 2002 CLASS:

1 Page 14 of 61

Florida Power A Progress Energy Cornr y*

Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

1 CATEGORY: B-G-1 ITEM: B6.10 Summary No.

Component I D Component Description System

System Description

B1.8.4.12 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT RC REACTOR COOLANT 26-207-13 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-208 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.8.4.13 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT RC REACTOR COOLANT 26-207-14 Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VT-01-209 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.8.4.14 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT RC REACTOR COOLANT 26-207-15 Workscope Report No.

Exam Results Work Reauest No.

Examination Remarks ISI VT-01-210 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.8.4.15 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT RC REACTOR COOLANT 26-207-16 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-211 Sat 366474 Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-17 System RC

System Description

REACTOR COOLANT Workscope Report No.

ISI VT-01-212 Summary No.

B11.8.4.17 Compon RCRE-1 Workscope Report No.

ISI VT-01-213 Exam Results Work Request No.

Examination Remarks Sat 366474 ent ID Component Description REACTOR VESSEL CLOSURE HEAD NUT 26-207-18 Exam Results Work Request No.

Examination Remarks Sat 366474 System RC Summary No.

Component ID Component Description B1.8.4.18 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT 26-207-19 Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VT-01-214 Sat 366474 Summary No.

Component ID Component Description B1.8.4.19 RCRE-1 REACTOR VESSEL CLOSURE HEAD NUT 26-207-20 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-215 Sat 366474 System

System Description

RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 Summary No.

11.8.4.16 Component ID RCRE-1

System Description

REACTOR COOLANT Page 15 of 61

Florida Power A Progress Energy Comrrpny Inservice Inspection Report Interval 3 1 Period 1 / Refuel Cycle 12 CLASS:

1 CATEGORY: B-G-1 ITEM: B6.30 Summary No.

B1.8.1.00 Workscope ISI ISI Component ID RCRE-1 Report No.

MT-01 -017 UT-01 -042 Exam Results Sat Sat Component Description REACTOR VESSEL CLOSURE STUD 25 207-1 Work Request No.

Examination Remarks 366474 366474 SSystem

System Description

RC REACTOR COOLANT Summary No.

Component ID Component Description System

System Description

B1.8.1.01 RCRE-1 REACTOR VESSEL CLOSURE STUD 25-RC REACTOR COOLANT 207-2 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01 -018 Sat 366474 IS!

UT-01 -043 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.8.1.02 RCRE-1 REACTOR VESSEL CLOSURE STUD 25-RC REACTOR COOLANT 207-3 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-019 Sat 366474 ISI UT-01-044 Sat 366474 Component ID RCRE-1 Report N MT-01-0 UT-01-0.

Report N MT-01-0 UT-01-01 Report No.

MT-01-022 UT-01 -047

10.

Exam Results 20 Sat 45 Sat Component ID RCRE-1 0o.

Exam Results

'21 Sat 46 Sat Component ID RCRE-1 Exam Results Sat Sat Component Description REACTOR VESSEL CLOSURE STUD 25 207-4 Work Request No.

Examination Remarks 366474 366474 Component Description REACTOR VESSEL CLOSURE STUD 25 207-5 Work Request No.

Examination Remarks 366474 366474 Component Description REACTOR VESSEL CLOSURE STUD 25 207-6 Work Request No.

Examination Remarks 366474 366474 t

Rystem A

escrlpCiorN RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT S

System Description

RC REACTOR COOLANT Page 16 of 61 Wednesday, January 16, 2002 Summary No.

B1.8.1.03 Workscope ISI IS!

Summary No.

B1.8.1.04 Workscope IS' ISI Summary No.

B1.8.1.05 Workscope IS' iSI

SFlorida Power A Progress Energy Com"sny CLASS:

1 CATEGORY: B-G-1 ITEM: B6.30 Component Description REACTOR VESSEL CLOSURE STUD 25 207-7 Work Request No.

Examination Remarks 366474 366474 System

System Description

RC REACTOR COOLANT Summary No.

Component ID Component Description System

System Description

B1.8.1.07 RCRE-1 REACTOR VESSEL CLOSURE STUD 25-RC REACTOR COOLANT 207-8 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-024 Sat 366474 isI UT-01-049 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.8.1.08 RCRE-1 REACTOR VESSEL CLOSURE STUD 25-RC REACTOR COOLANT 207-9 Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI MT-01-025 Sat 366474 ISI UT-01-050 Sat 366474 Component ID RCRE-1 Report No.

MT-01-026 UT-01-051 Exam Results Sat Sat Component ID RCRE-1 Report No.

Exam Results MT-01-027 Sat UT-01-052 Sat Component ID RCRE-1 Report No.

MT-01-028 UT-01 -053 Exam Results Sat Sat Component Description REACTOR VESSEL CLOSURE STUD 25 207-10 Work Request No.

Examination Remarks 366474 366474 Component Description REACTOR VESSEL CLOSURE STUD 25 207-11 Work Request No.

Examination Remarks 366474 366474 Component Description REACTOR VESSEL CLOSURE STUD 25 207-12 Work Request No.

Examination Remarks 366474 366474 A

escr ptC on RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 1 Refuel Cycle 12 Component ID RCRE-1 Summary No.

B1.8.1.06 Workscope IS!

ISI Report No.

MT-01 -023 UT-01-048 Exam Results Sat Sat Summary No.

B1.8.1.09 Workscope IS' ISI Summary No.

B1.8.1.10 Workscope iSI ISI Summary No.

B1.8.1.11 Workscope ISI is]

Page 17 of 61

Florida Power A Progress Energy Con, rn' Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-G-1 ITEM: B6.30 Component Description REACTOR VESSEL CLOSURE STUD 25 207-13 Work Request No.

Examination Remarks 366474 366474 System

System Description

RC REACTOR COOLANT Summary No.

Component ID Component Description System

System Description

B1.8.1.13 RCRE-1 REACTOR VESSEL CLOSURE STUD 25-RC REACTOR COOLANT 207-14 Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI MT-01-030 Sat 366474 ISI UT-01-055 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.8.1.14 RCRE-1 REACTOR VESSEL CLOSURE STUD 25-RC REACTOR COOLANT 207-15 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01 -031 Sat 366474 ISI UT-01 -056 Sat 366474 Component ID RCRE-1 Report No.

MT-01 -032 UT-01-057 Exam Results Sat Sat Component I D RCRE-1 Report No.

Exam Results MT-01-033 Sat UT-01-058 Sat Component I D RCRE-1 Report No.

MT-01-034 UT-01 -059 Exam Results Sat Sat Component Description REACTOR VESSEL CLOSURE STUD 25 207-16 Work Request No.

Examination Remarks 366474 366474 Component Description REACTOR VESSEL CLOSURE STUD 25 207-17 Work Request No.

Examination Remarks 366474 366474 Component Description REACTOR VESSEL REACTOR VESSEL CLOSURE STUD 25-207-18 Work Request No.

Examination Remarks 366474 366474 t

Rystem A

escnpOon RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 CLASS:

1 Component ID RCRE-1 Summary No.

B1.8.1.12 Workscope IS' ISI Report No.

MT-01-029 UT-01-054 Exam Results Sat Sat Summary No.

B1.8.1.15 Workscope ISI ISI Summary No.

B1.8.1.16 Workscope ISI ISI Summary No.

B1.8.1.17 Workscope IS' ISI Page 18 of 61

'Florida Power A Progress Energy Csmsrsan.

Inservice Inspection Report Interval 3 1 Period 1 / Refuel Cycle 12 CATEGORY: B-G-1 ITEM: B6.30 Component Description REACTOR VESSEL REACTOR VESSEL CLOSURE STUD 25-207-19 Work Request No.

Examination Remarks 366474 366474 System

System Description

RC REACTOR COOLANT Summary No.

Component I D Component Description System

System Description

B1.8.1.19 RCRE-1 REACTOR VESSEL REACTOR VESSEL RC REACTOR COOLANT CLOSURE STUD 25-207-20 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01 -036 Sat 366474 ISI UT-01-061 Sat 366474 ITEM: B6.40 Summary No.

Component ID Component Description System

System Description

B13.9.1.01 RCRE-1 REACTOR VESSEL REACTOR VESSEL RC REACTOR COOLANT THREADS IN FLANGE STUD 1 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-094 Sat 366471 Summary No.

Component ID Component Description System

System Description

B1.9.1.02 RCRE-1 REACTOR VESSEL THREADS IN FLANGE RC REACTOR COOLANT STUD 2 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01 -095 Sat 366471 Summary No.

B13.9.1.03 Component ID RCRE-1 Workscope Report No.

ISI UT-01 -096 Summary No.

B13.9.1.04 Exam Results Sat Component ID RCRE-1 Component Description REACTOR VESSEL THREADS IN FLANGE STUD 3 Work Request No.

Examination Remarks 366471 Component Description REACTOR VESSEL THREADS IN FLANGE STUD 4 System

System Description

RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT Workscoee Report No.

ISI UT-01-097 Exam Results Work Request No.

Examination Remarks Sat 366471 Summary No.

B13.9.1.05 Component ID RCRE-1 Workscope Report No.

ISI UT-01-098 Exam Results Sat Component Description REACTOR VESSEL THREADS IN FLANGE STUD 5 Work Request No.

Examination Remarks 366471 System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 CLASS:

1 Component ID RCRE-1 Summary No.

B1.8.1.18 Workscope IS' ISI Report No.

MT-01-035 UT-01-060 Exam Results Sat Sat Page 19 of 61

Florida Power A Progress Energy Corr~Tn Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-G-1 ITEM: B6.40 Summary No.

B13.9.1.06 Workscope Report r, ISI UT-01-0 Component ID RCRE-1 Jo.

Exam Results 99 Sat Component Description REACTOR VESSEL THREADS IN FLANGE STUD 6 Work Request No.

Examination Remarks 366471 System RC

System Description

REACTOR COOLANT Summary No.

Component ID Component Description System

System Description

B1.9.1.07 RCRE-1 REACTOR VESSEL THREADS IN FLANGE RC REACTOR COOLANT STUD 7 Workscope Report No.

Exam Results Work Request No.

Examination Remarks IS1 UT-01-100 Sat 366471 Summary No.

Component ID Component Description System

System Description

B1.9.1.08 RCRE-1 REACTOR VESSEL THREADS IN FLANGE RC REACTOR COOLANT STUD 8 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-101 Sat 366471 Summary No.

Component ID Component Description System

System Description

B1.9.1.09 RCRE-1 REACTOR VESSEL THREADS IN FLANGE RC REACTOR COOLANT STUD 9 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01 -102 Sat 366471 Summary No.

B1.9.1.10 Compon RCRE-1 Workscope Report No.

ISI UT-01-103 ent ID Component Description REACTOR VESSEL THREADS IN FLANGE STUD 10 Exam Results Work Request No.

Examination Remarks Sat 366471 t

RysteAC escrCpOLon RC REACTOR COOLANT Summary No.

B1.9.1.11 Component ID RCRE-1 Workscope Report No.

ISI UT-01-104 Summary No.

B1.9.1.12 Workscope ISI Summary No.

B1.9.1.13 Exam Results Sat Component ID RCRE-1 Report No.

UT-01-105 Exam Results Sat Component I D RCRE-1 Workscope Report No.

ISI UT-01-106 Exam Results Sat Component Description REACTOR VESSEL THREADS IN FLANGE STUD 11 Work Request No.

Examination Remarks 366471 Component Description REACTOR VESSEL THREADS IN FLANGE STUD 12 Work Request No.

Examination Remarks 366471 Component Description REACTOR VESSEL THREADS IN FLANGE STUD 13 Work Request No.

Examination Remarks 366471 System RC System RC System RC Wednesday, January 16, 2002 CLASS:

1 System Description

REACTOR COOLANT

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT Page 20 of 61

Florida Power A Progress Energy Co.om*sany Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-G-1 ITEM: B6.40 Summary No.

B13.9.1.14 Component ID RCRE-1 Workscope Report No.

Exam Results ISI UT-01-107 Sat Component Description REACTOR VESSEL THREADS IN FLANGE STUD 14 Work Request No.

Examination Remarks 366471 System RC

System Description

REACTOR COOLANT Summary No.

Component ID Component Description System

System Description

B1.9.1.16 RCRE-1 REACTOR VESSEL THREADS IN FLANGE RC REACTOR COOLANT STUD 16 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-109 Sat 366471 Summary No.

Component I D Component Description System

System Description

B1.9.1.17 RCRE-1 REACTOR VESSEL THREADS IN FLANGE RC REACTOR COOLANT STUD 17 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-110 Sat 366471 Summary No.

Component ID Component Description System

System Description

B1.9.1.18 RCRE-1 REACTOR VESSEL THREADS IN FLANGE RC REACTOR COOLANT STUD 18 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-111 Sat 366471 Summary No.

B1.9.1.19 Compon RCRE-1 Workscope Report No.

ISI UT-01-112 Summary No.

Compon B1.9.1.20 RCRE-1 Workscope Report No.

ISI UT-01-113 Summary No.

B13.9.1.21 Compon RCRE-1 Workscope Report No.

ISI UT-01-108 nent ID Component Description REACTOR VESSEL THREADS IN FLANGE STUD 19 Exam Results Work Request No.

Examination Remarks Sat 366471 nent ID Component Description REACTOR VESSEL THREADS IN FLANGE STUD 20 Exam Results Work Request No.

Examination Remarks Sat 366471 nent ID Component Description REACTOR VESSEL THREADS IN FLANGE STUD 21 Exam Results Work Request No.

Examination Remarks Sat 366471 System

System Description

RC REACTOR COOLANT System RC

System Description

REACTOR COOLANT System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 CLASS:

1 Page 21 of 61

S Florida Power A Progress Energy Comrff,"y CLASS:

1 CATEGORY: B-G-1 ITEM: B6.50 Summary No.

B1.10.1.01 Workscope ISI Component ID RCRE-1 Report No.

VT-01-216 Component Description REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-1 System RC

System Description

REACTOR COOLANT Exam Results Work Request No.

Examination Remarks Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.10.1.02 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-2 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-217 Sat 366474 Summary No.

Component I D Component Description System

System Description

B1.10.1.03 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-3 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-218 Sat 366474 Summary No.

Component I D Component Description System

System Description

B1.10.1.04 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-4 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-219 Sat 366474 Summary No.

B1.10.1.05 Workscope Report r, ISI VT-01-2 Summary No.

B1.10.1.06 Workscope Report ISI VT-01-2 Summary No.

B1.10.1.07 Component ID RCRE-1 Jo.

Exam Results 20 Sat Component ID RCRE-1

10.

21 Exam Results Sat Component I D RCRE-1 Component Description REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-5 Work Request No.

Examination Remarks 366474 Component Description REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-6 Work Request No.

Examination Remarks 366474 Component Description REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-7 t

Rystem A

escCrpion RC REACTOR COOLANT System RC System RC

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks is]

VT-01 -222 Sat 366474 Component ID RCRE-1 Component Description REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-8 System RC

System Description

REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-223 Sat 366474 Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

B1.10.1.08 Page 22 of 61

S Florida Power A Progress Energy.om rny CLASS:

1 CATEGORY: B-G-1 ITEM: B6.50 Summary No.

B11.10.1.09 Component ID RCRE-1 Workscope Report No.

Exam Results ISI VT-01 -224 Sat Component Description REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-9 Work Request No.

Examination Remarks 366474 System RC

System Description

REACTOR COOLANT Summary No.

Component ID Component Description System

System Description

B13.10.1.10 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-10 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-225 Sat 366474 Summary No.

Component ID Component Description System

System Description

B1.10.1.11 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-11 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -226 Sat 366474 Summary No.

Comoonent ID Component Description System

System Description

B1.10.1.12 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-12 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -227 Sat 366474 Component ID RCRE-1 Report No.

VT-01-228 Exam Results Sat Component Description REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-13 Work Request No.

Examination Remarks 366474 Summary No.

Component ID Component Description B1.10.1.14 RCRE-1 REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-14 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -229 Sat 366474 Summary No.

Component ID Component Description B13.10.1.15 RCRE-1 REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-15 Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VT-01-230 Sat 366474 Component I D RCRE-1 Component Description REACTOR VESSEL CLOSURE WASHER AND BUSHING 14/27-207-16 Sys ATORem escOpTiAn RC REACTOR COOLANT System RC System RC System RC

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT

System Description

REACTOR COOLANT Workscope Report No.

ISI VT-01-231 Exam Results Work Request No.

Examination Remarks Sat 366474 Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

B1.10.1.13 Workscope ISI Summary No.

B1.10.1.16 Page 23 of 61

Florida Power A Progress Energy Comran, CLASS:

1 CATEGORY: B-G-1 ITEM: B6.50 Summary No.

Component I D Component Description B1.10.1.17 RCRE-1 REACTOR VESSEL CLOSURE WASHER AND BUSHING14/27-207-17 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-232 Sat 366474 System RC

System Description

REACTOR COOLANT Summary No.

Component I D Component Description System

System Description

B13.10.1.18 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-18 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -233 Sat 366474 Summary No.

Component I D Component Description System

System Description

B1.10.1.19 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-19 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-234 Sat 366474 Summary No.

Component ID Component Description System

System Description

B13.10.1.20 RCRE-1 REACTOR VESSEL CLOSURE WASHER RC REACTOR COOLANT AND BUSHING 14/27-207-20 Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -235 Sat 366474 CATEGORY: B-G-2 ITEM: B7.20 Summary No.

B2.5.2 Compon RCT-1 Workscope Report No.

ISI VT-01-102 ient ID Component Description MK75 HTR BDL TOP VESSEL BOLTS, STUDS, AND NUTS Exam Results Work Request No.

Examination Remarks Sat 366464 System

System Description

RC REACTOR COOLANT ITEM: B7.50 Component ID MUHE-1C PIPING Component Description FLANGE BOLTS, STUDS, AND NUTS System

System Description

MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -254 Sat 366475 ITEM: B7.70 Component ID RCV-8 Component Description MK-10 VALVE BOLTS, STUDS, AND NUTS System

System Description

RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VT-01-103 Sat 366464 Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

B4.12.1 Summary No.

B6.9.03 Page 24 of 61

Florida Power A Progress Energy Co0 po' r Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-G-2 ITEM: B7.70 Summary No.

B6.9.09 Component ID MUV-161 Workscope Report No.

Exam Results ISI VT-01-251 Sat Component Description MK-18 VALVE BOLTS, STUDS, AND NUTS Work Request No.

Examination Remarks 366464 System MU

System Description

MAKE-UP Summary No.

Component ID Component Description System

System Description

B6.9.13 MUV-160 MK-18 VALVE BOLTS, STUDS, AND NUTS MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VT-01 -252 Sat 366475 Summary No.

Component ID Component Description System

System Description

B6.9.23 MUV-37 MK-18 VALVE BOLTS, STUDS, AND NUTS MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VT-01-239 Sat 366468 Summary No.

Component ID Component Description System

System Description

B6.9.27 RCV-1 1 VLV-PZR BOLTS, STUDS, AND NUTS RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -104 Sat 366464 ITEM: B7.80 Component Description CRDM HOLD DOWN BOLT ASSEMBLY 1114 System

System Description

RC REACTOR COOLANT Workscope Report No.

Exam Results PSI VT-01 -258 Sat Summary No.

Component ID B1.11.71 DRRD-1 Workscope Report No.

Exam Results PSI VT-01-259 Sat Summary No.

Component ID B1.11.72 DRRD-1 Workscope Report No.

Exam Results PSI VT-01-260 Sat Work Request No.

369965 Examination Remarks Preservice Examination.

Component Description CRDM FLANGE RING (SPLIT NUT) 1114 Work Request No.

369965 System RC

System Description

REACTOR COOLANT Examination Remarks Preservice Examination.

Component Description CRDM HOLD DOWN BOLT ASSEMBLY 1115 Work Request No.

369965 System RC

System Description

REACTOR COOLANT Examination Remarks Preservice Examination.

Wednesday, January 16, 2002 CLASS:

1 Summary No.

B1.11.70 Component ID DRRD-1 Page 25 of 61

S Florida Power A Progress Energy Comr,ý.ny CLASS:

1 CATEGORY: B-G-2 ITEM: B7.80 Component Description CRDM FLANGE RING (SPLIT NUT) 1115 Exam Results Work Request No.

Sat 369965 Ssterm RC

System Description

REACTOR COOLANT Examination Remarks Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.74 DRRD-1 CRDM HOLD DOWN BOLT ASSEMBLY RC REACTOR COOLANT 1116 Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01-262 Sat 369965 Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.75 DRRD-1 CRDM FLANGE RING (SPLIT NUT) 1116 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01 -263 Sat 369965 Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.76 DRRD-1 CRDM HOLD DOWN BOLT ASSEMBLY RC REACTOR COOLANT 1117 Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01-264 Sat 369965 Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.77 DRRD-1 CRDM FLANGE RING (SPLIT NUT) 1117 RC REACTOR COOLANT Workscope Report No.

PSI VT-01-265 Summary No.

B1.11.78 Compon DRRD-1 Workscope Report No.

PSI VT-01 -266 Exam Results Work Request No.

Sat 369965 Examination Remarks Preservice Examination.

nent I D Component Description CRDM HOLD DOWN BOLT ASSEMBLY 1118 Exam Results Work Request No.

Examination Remarks Sat 369965 Preservice Examination.

System RC

System Description

REACTOR COOLANT Component Description CRDM FLANGE RING (SPLIT NUT) 1118 System

System Description

RC REACTOR COOLANT Workscope Report No.

PSI VT-01-267 Summary No.

B1.11.80 Compon DRRD-1 Workscope Report No.

PSI VT-01-268 Exam Results Sat Work Request No.

369965 Examination Remarks Preservice Examination.

ent ID Component Description CRDM HOLD DOWN BOLT ASSEMBLY 1119 Exam Results Work Request No.

Examination Remarks Sat 369965 Preservice Examination.

System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

B1.11.73 Workscope PSI Component ID DRRD-1 Report No.

VT-01 -261 Summary No.

B 1.11.79 Component I D DRRD-1 Page 26 of 61

Florida Power A Progress Energy Cominany Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-G-2 ITEM: B7.80 Component Description CRDM FLANGE RING (SPLIT NUT) 1119 Workscope Report No.

Exam Results Work Request No.

PSI VT-01 -269 Sat 369965 System RC

System Description

REACTOR COOLANT Examination Remarks Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.82 DRRD-1 CRDM HOLD DOWN BOLT ASSEMBLY RC REACTOR COOLANT 1120 Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01-270 Sat 369965 Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.83 DRRD-1 CRDM FLANGE RING (SPLIT NUT) 1120 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01 -271 Sat 369965 Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.84 DRRD-1 CRDM HOLD DOWN BOLT ASSEMBLY RC REACTOR COOLANT 1121 Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01-272 Sat 369965 Preservice Examination.

Component ID DRRD-1 Report No.

VT-01-273 Component Description CRDM FLANGE RING (SPLIT NUT) 1121 Exam Results Work Request No.

Sat 369965 System RC

System Description

REACTOR COOLANT Examination Remarks Preservice Examination.

Summary No.

Component I D Component Description B1.11.86 DRRD-1 CRDM HOLD DOWN BOLT ASSEMBLY 1122 Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01 -274 Sat 369965 Preservice Examination.

Component ID DRRD-1 Component Description CRDM FLANGE RING (SPLIT NUT) 1122 System RC

System Description

REACTOR COOLANT System

System Description

RC REACTOR COOLANT Workscope Report No.

PSI VT-01-275 Exam Results Work Request No.

Sat 369965 Examination Remarks Preservice Examination.

Summary No.

Component ID Component Description B1.11.88 DRRD-1 CRDM HOLD DOWN BOLT ASSEMBLY 1123 Workscope Report No.

Exam Results Work Reauest No.

Examination Remarks PSI VT-01 -276 Sat 369965 Preservice Examination.

System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 CLASS:

1 Summary No.

B1.11.81 Component ID DRRD-1 Summary No.

B1.11.85 Workscope PSI Summary No.

B1.11.87 Page 27 of 61

SFlorida Power A Progress Energy Comr n}ny CLASS:

1 CA TEGOR Y: B-G-2 ITEM: B7.80 Component Description CRDM FLANGE RING (SPLIT NUT) 1123 System RC

System Description

REACTOR COOLANT Workscope Report !*

PSI VT-01-2 4o.

Exam Results 77 Sat Work Request No.

369965 Examination Remarks Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.90 DRRD-1 CRDM HOLD DOWN BOLT ASSEMBLY RC REACTOR COOLANT 1124 Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01-278 Sat 369965 Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.91 DRRD-1 CRDM FLANGE RING (SPLIT NUT) 1124 RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01-279 Sat 369965 Preservice Examination.

Summary No.

Component ID Component Description System

System Description

B1.11.92 DRRD-1 CRDM HOLD DOWN BOLT ASSEMBLY RC REACTOR COOLANT 1125 Workscope Report No.

Exam Results Work Request No.

Examination Remarks PSI VT-01 -280 Sat 369965 Preservice Examination.

Component Description CRDM FLANGE RING (SPLIT NUT) 1125 t

RsteAC escrCptLAn RC REACTOR COOLANT Workscope Report No.

PSI VT-01-281 Exam Results Work Request No.

Sat 369965 Examination Remarks Preservice Examination.

CATEGORY: B-H Summary No.

B2.8.1 1 Compon RCT-1 Workscope Report No.

ISI MT-01-013 ITEM: B8.20 nent ID Component Description System MK126/128-3 Y-Z AXIS VESSEL RC INTEGRALLY WELDED ATTACHMENT Exam Results Work Request No.

Examination Remarks Sat 366464 Access limited due to support structure.

System Description

REACTOR COOLANT Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

B1.11.89 Component ID DRRD-1 Summary No.

B1.11.93 Component ID DRRD-1 Page 28 of 61

S Florida Power A Progress Energy Compny CLASS:

1 CATEGORY: B-J ITEM: B9.11 Component Description MK34 ON MKA32 NOZZLE-TO-SAFE END Work Request No.

Examination Remarks 366468 366468 System

System Description

RC REACTOR COOLANT Summary No.

Component ID Comoonent Description System

System Description

B4.5.192 PIPING WELD MK 32 TO 31 PIPE-TO-ELBOW RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI MT-01 -046 Sat 366464 ISI UT-01 -089 Sat 366464 Summary No.

Component I D Component Description System

System Description

B4.5.195 PIPING WELD MK24 TO 22 PIPE-TO-PIPE RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-054 Sat 366464 ISI UT-01-093 Sat 366464 Component ID PIPING WELD Report No.

Exam Results MT-01 -056 Sat UT-01-125 Sat Component I D PIPING WELD Report No.

MT-01-038 UT-01-034 Exam Results Sat Sat Component ID PIPING WELD Report No.

MT-01-037 UT-01-126 Exam Results Sat Sat Component Description MK65 TO 67 NOZZLE-TO-PIPE t

System A

esOCptOLn RC REACTOR COOLANT Work Request No.

Examination Remarks 366464 366464 Component Description MK62 TO 57 ELBOW-TO-PIPE Work Request No.

Examination Remarks 366464 366464 Component Description MK67 TO 45 PIPE-TO-ELBOW Work Request No.

Examination Remarks 366464 366464 System

System Description

RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Component I D PIPING WELD Summary No.

B4.1.27 Workscope ISI is]

Report No.

PT-01-023 UT-01-070 Exam Results Sat Sat Summary No.

B4.5.206 Workscope ISI ISI Summary No.

B4.5.207 Workscope ISI ISI Summary No.

B4.5.216 Workscope is]

ISI Page 29 of 61

Florida Power A Progress Energy CNr-,any Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-J ITEM: B9.11 Summary No.

B4.5.254 Workscope IS[

ISI Component ID PIPING WELD Report No.

PT-01 -024 UT-01-071 Exam Results Sat Sat Component Description DH-161 SAFE END-TO-PIPE System

System Description

DH DECAY HEAT Work Request No.

Examination Remarks 366468 366468 Summary No.

Component ID Component Description System

System Description

B4.5.64 PIPING WELD CF-9 ELBOW-TO-PIPE CF CORE FLOOD Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI PT-01-034 Sat 366464 ISI UT-01-119 Sat 366464 ITEM: B9.21 Summary No.

Component ID Component Description System

System Description

B4.1.89 PIPING WELD MK 46 TO 47 NOZZLE-TO-SAFE END RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI PT-01 -022 Sat 366468 ISI UT-01-069 Sat 366468 Component Description MU-395 VALVE-TO-PIPE Work Request No.

Examination Remarks 366475 366475 Single-Sided Examination.

Component Description MU-247C PIPE-TO-ELBOW Work Request No.

Examination Remarks 366475 366475 Component Description MU-249A PIPE-TO-PIPE m

ystem M

esc-U pon MU MAKE-UP System

System Description

MU MAKE-UP System

System Description

MU MAKE-UP Work Request No.

Examination Remarks 366475 366475 Wednesday, January 16, 2002 CLASS:

1 Component ID PIPING WELD Report No.

PT-01-026 UT-01 -115 Exam Results Sat Sat Component ID PIPING WELD Summary No.

B4.5.165 Workscope ISI AUG Summary No.

B4.5.166 Workscope ISI AUG Summary No.

B4.5.167 Workscope ISI AUG Report No.

PT-01-029 UT-01-116 Exam Results Sat Sat Component ID PIPING WELD Report No.

PT-01-027 UT-01 -117 Exam Results Sat Sat Page 30 of 61

S Florida Power A Progress Energy tom,ny Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-J ITEM: B9.21 Component ID PIPING WELD Report No.

PT-01-030 UT-01 -118 Exam Results Sat Sat Component Description MU-250D PIPE-TO-ELBOW System

System Description

MU MAKE-UP Work Request No.

Examination Remarks 366475 366475 Summary No.

Component I D Component Description System

System Description

B4.5.169 PIPING WELD MU-251B ELBOW-TO-PIPE MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI PT-01-015 Sat 366468 AUG UT-01-037 Sat 366468 Summary No.

Component ID Component Description System

System Description

B4.5.170 PIPING WELD MU-251A PIPE-TO-ELBOW MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI PT-01 -016 Sat 366468 AUG UT-01-038 Sat 366468 Summary No.

B4.5.171 Workscope ISI AUG Component ID PIPING WELD Report No.

PT-01 -017 UT-01-039 Exam Results Sat Sat Summary No.

Component ID B4.5.172 PIPING WELD Workscope Report No.

Exam Results iSI PT-01-033 Sat Summary No.

Component ID B4.5.306 PIPING WELD Workscope ISI AUG Summary No.

B4.5.319 Report No.

Exam Results PT-01-018 Sat UT-01 -040 Sat Component ID PIPING WELD Component Description MU-252A PIPE-TO-ELBOW Work Request No.

Examination Remarks 366468 366468 Component Description MU-253A TEE-TO-PIPE Work Request No.

Examination Remarks 366468 Component Description MU-402 VALVE-TO-PIPE Work Request No.

Examination Remarks 366468 366468 Single-Sided Examination.

Component Description MU-403 BRANCH-TO-TEE System

System Description

MU MAKE-UP System

System Description

MU MAKE-UP System

System Description

MU MAKE-UP System

System Description

MU MAKE-UP Workscope Report No.

ISI PT-01 -032 Exam Results Work Request No.

Examination Remarks Sat 366468 Wednesday, January 16, 2002 CLASS:

1 Summary No.

B4.5.168 Workscope ISI AUG Page 31 of 61

Florida Power A Progress Energy Comsnan,,,

Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-J ITEM: B9.21 Component Description MK 64 TO 1 NOZZLE-TO-ELBOW System RC

System Description

REACTOR COOLANT Workscope Report No.

ISI PT-01-011 Exam Results Sat Work Request No.

Examination Remarks 366468 Summary No.

Component ID Component Description System

System Description

B4.5.556 PIPING WELD MK 2 TO 3 - W7 TEE-TO-REDUCER RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI PT-01-014 Sat 366464 Summary No.

Component ID Component Description System

System Description

B4.5.614 PIPING WELD MU-90-173 SAFE END-TO-PIPE MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI PT-01-020 Sat 366468 AUG UT-01 -036 Sat 366468 Summary No.

Component ID Component Description System

System Description

B4.5.646 PIPING WELD MU-90-172 PIPE-TO-PIPE MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI PT-01-019 Sat 366468 AUG UT-01 -091 Sat 366468 ITEM: B9.31 Component Description MK31 TO 34 ELBOW-TO-NOZZLE System

System Description

RC REACTOR COOLANT Work Request No.

Examination Remarks 366468 366468 Component Description MK23 TO 25 PIPE-TO-NOZZLE System

System Description

RC REACTOR COOLANT Work Request No.

Examination Remarks 366464 366464 Wednesday, January 16, 2002 CLASS:

1 Summary No.

B4.5.534 Component ID PIPING WELD Component ID PIPING WELD Report No.

MT-01-055 UT-01-120 Summary No.

B4.6.1 Workscope ISI ISI Summary No.

B4.6.3 Workscope ISI ISI Exam Results Sat Sat Component I D PIPING WELD Report No.

MT-01 -051 UT-01-121 Exam Results Sat Sat Page 32 of 61

S Florida Power A Progress Energy Corr~wrr.,

CLASS:

1 CATEGORY: B-J ITEM: B9.32 Component Description MK64 TO MKA63 DRAIN PIPE-TO-NOZZLE System

System Description

RC REACTOR COOLANT Workscope Report No.

ISI PT-01 -028 Exam Results Work Request No.

Examination Remarks Sat 366468 ITEM: B9.40 Summary No.

Component ID Component Description System

System Description

B4.5.591 PIPING WELD RCP-1 B SEAL COOLER PIPE-TO-ELBOW RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks SI PT-01-012 Sat 366464 Summary No.

Component ID Component Description System

System Description

B4.5.595 PIPING WELD RCP-1B SEAL COOLER PIPE-TO-ELBOW RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI PT-01-013 Sat 366464 CATEGORY: B-K-1 ITEM: B10.10 Summary No.

Component ID B4.9.14 PIPING INTEGRAL ATTACHMENT Workscope Report No.

Exam Results ISI PT-01-021 Sat Component Description RCH-68 INTEGRAL ATTACHMENT Work Request No.

Examination Remarks 366464 System

System Description

RC REACTOR COOLANT CATEGORY: B-M-1 ITEM: B12.30 Component ID RCV-11 Report No.

Exam Results PT-01 -009 Sat Component ID RCV-1 1 Component Description VALVE BODY-TO-FLANGE WELD Work Request No.

Examination Remarks 366464 Component Description VALVE BODY-TO-FLANGE WELD System

System Description

RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT Workscope Report No.

ISI PT-01-010 Exam Results Work Request No.

Examination Remarks Sat 366464 Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

B4.1.71 Component ID PIPING WELD Summary No.

B6.6.02.01 Workscope ISI Summary No.

B6.6.02.02 Page 33 of 61

Florida Power A Progress Energy Com'any Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-M-1 ITEM: B12.40 Component Description VALVE BODY-TO-CANOPY WELD Work Request No.

366978 366978 366978 System

System Description

DH DECAY HEAT Examination Remarks PT Examination UT Examination UT Examination CATEGORY: B-N-1 ITEM: B13.10 Summary No.

Component ID Component Description System

System Description

B1.15.1.A RCRE-1 EXPOSED REACTOR VESSEL INTERIOR RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-174 Sat 366471 CATEGORY: B-P ITEM: B15.00.BP Summary No.

Component ID Component Description System

System Description

B15.100.1A RCT-1 VESSEL MANWAY BOLTED CONNECTION RC REACTOR COOLANT Workscope Report No.

Exam Results Work Reauest No.

Examination Remarks ISI VT-01-072 Sat 366483 Performed Using SP-204 Summary No.

B15.100.1B Component I D RCRE-1 Workscope Report No.

Exam Results ISI VT-01 -084 Sat Summary No.

B15.100.1C Workscope Report r, ISI VT-01-0 Summary No.

B15.100.1D Component I D RCSG-1 B Jo.

Exam Results A F; Unsat Component I D RCSG-1B Workscope Report No.

Exam Results ISI VT-01-073 Sat Component Description VESSEL HEAD FLANGE BOLTED CONNECTION Work Request No.

Examination Remarks 366483 Performed Using SP-204 Component Description VESSEL LOWER INSPECTION COVER BOLTED CONNECTION Work Request No.

Examination Remarks 366483 Performed Using SP-204 Component Description VESSEL LOWER MANWAY BOLTED CONNECTION Work Request No.

Examination Remarks 366483 Performed Using SP-204 SRtem RC

System Description

REACTOR COOLANT System

System Description

RC REACTOR COOLANT System

System Description

RC REACTOR COOLANT Wednesday, January 16, 2002 CLASS:

1 Component ID DHV-3 Summary No.

B6.6.7 Workscope PSI PSI PSI Report No.

VE-01 -032 VE-01 -033 VE-01 -076 Exam Results Sat Sat Sat Page 34 of 61

Florida Power A Progress Energy Corr'*npa Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-P Summary No.

B15.100.1E Component 11 RCSG-1B Workscope Report No.

Exam ISI VT-01-074 ITEM: B15.00.BP Component Description VESSEL UPPER HAND HOLE BOLTED CONNECTION Results Work Request No.

Examination Rem Sat 366483 Performed Using System RC

System Description

REACTOR COOLANT arks SP-204 Summary No.

Component ID Component Description System

System Description

B15.100.1F RCSG-1B VESSEL UPPER MANWAY BOLTED RC REACTOR COOLANT CONNECTION Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-079 Sat 366483 Performed Using SP-204 Summary No.

Component ID Component Description System

System Description

B15.100.1G RCSG-1A LOWER INSPECTION COVER BOLTED RC REACTOR COOLANT CONNECTION Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-086 Sat 366483 Performed Using SP-204 Summary No.

Component ID Component Description System

System Description

B15.100.1H RCSG-1A LOWER MANWAY BOLTED CONNECTION RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-087 Sat 366483 Performed Using SP-204 Summary No.

Component I D Component Description B15.100.11 RCSG-1A VESSEL UPPER HAND HOLE BOLTED CONNECTION Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-075 Sat 366483 Performed Using SP-204 Summary No.

Component ID Component Description B15.100.1J RCSG-1A VESSEL UPPER MANWAY BOLTED CONNECTION RCst em Sr escrlpCOLn RC REACTOR COOLANT SCstem RC

System Description

REACTOR COOLANT Workscope Report No.

Exam Results ISI VT-01-080 Sat Work Request No.

366483 Examination Remarks Performed Using SP-204 Component Description VALVE FLANGE BOLTED CONNECTION System RC

System Description

REACTOR COOLANT Workscope Report No.

ISI VT-01 -077 Exam Results Sat Work Request No.

366483 Examination Remarks Performed Using SP-204 Component Description VALVE FLANGE BOLTED CONNECTION System RC

System Description

REACTOR COOLANT Workscope Report No.

ISI VT-01-078 Exam Results Sat Work Request No.

366483 Examination Remarks Performed Using SP-204 Wednesday, January 16, 2002 CLASS:

1 Summary No.

B15.100.1L Component ID RCV-10 Summary No.

B15.100.1M Component ID RCV-11 Page 35 of 61

Florida Power A Progress Energy Company Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: B-P ITEM: B15.00.BP Component Description HEATER BUNDLE BOLTED CONNECTIONS System

System Description

RC REACTOR COOLANT Workscope Report No.

Exam Results ISI VT-01-088 Sat Work Request No.

366483 Examination Remarks Performed Using SP-204 Summary No.

Component ID Component Description System

System Description

B15.100.1P RCV-38 VALVE BONNET BOLTED CONNECTION RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-089 Sat 366483 Performed Using SP-204 Summary No.

Component ID Component Description System

System Description

B15.100.2 ALL CLASS 1 CLASS 1 SYSTEM LEAKAGE TEST RC REACTOR COOLANT PRESSURE RETAINING COMPONENTS Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-065 Sat 366485 Performed during Mode 3 SP-204 CATEGORY: B-Q ITEM: B16.10 Summary No.

Component ID Component Description System

System Description

B16.10.1 RCSG-1A ONCE-THROUGH STEAM GENERATOR RC REACTOR COOLANT TUBES Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-074 Sat 367494 ET Examination Component Description ONCE-THROUGH STEAM GENERATOR TUBES System RC

System Description

REACTOR COOLANT Workscope Report No.

ISI VE-01-075 Exam Results Work Reauest No.

Sat 367494 Examination Remarks ET Examination CATEGORY: F-A ITEM: F1.1OA Summary No.

MUH-8 Component ID Component Description COMPONENT SUPPORT ROD System

System Description

MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-255 Sat 366476 Wednesday, January 16, 2002 CLASS:

1 Summary No.

B15.100.1N Component ID RCT-1 Summary No.

B1 6.10.2 Component ID RCSG-1B Page 36 of 61

)j Florida Power A Progress Energy Comsany Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

1 CATEGORY: F-A ITEM: F1.1OB Component ID Component Description COMPONENT SUPPORT GUIDE SSystem

System Description

RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks IS[

VT-01-256 Sat 366468 Summary No.

Component ID Component Description System

System Description

RCH-TYP-123-2 COMPONENT SUPPORT RESTRAINT RC REACTOR COOLANT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -253 Sat 366464 ITEM: F1.10C Summary No.

Component ID Component Description System

System Description

CFH-1 1 COMPONENT SUPPORT SPRING CAN CF CORE FLOOD Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-185 Sat 366464 Summary No.

Component ID Component Description System

System Description

CFH-1 9 COMPONENT SUPPORT SNUBBER CF CORE FLOOD Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-066 Sat 366464 Performed Using SP-201 Summary No.

MUH-80 Component ID COMPONENT SUPPORT Workscope Report No.

Exam Results ISI VE-01-034 Sat Summary No.

Component ID RCH-72 COMPONENT SUPPORT Component Description SNUBBER Work Request No.

E 366468 F

Component Description CONSTANT System MU

System Description

MAKE-UP

xamination Remarks

'erformed Using SP-201 System

System Description

RC REACTOR COOLANT Work Request No.

Examination Remarks 366464 367656 Wednesday, January 16, 2002 Summary No.

RCH-578 Workscope ISI PSI Report No.

VT-01-184 VT-01 -282 Exam Results Sat Sat Page 37 of 61

Florida Power A Progress Energy Cormawn, Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: C-A ITEM: C1.10 Component Description OTSG MK3-TO-2 SHELL-TO-NOZZLE BELT WELD System

System Description

MS MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-114 Sat 366464 CATEGORY: C-B ITEM: C2.21 Summary No.

Component ID Component Description System

System Description

C1.2.1A RCSG-1A OTSG MK14-3 X-Y AXIS VESSEL NOZZLE-MS MAIN STEAM TO-SHELL WELD Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-012 Sat 366464 ISI UT-01 -028 Sat 366464 ITEM: C2.22 Summary No.

Component I D Component Description System

System Description

C1.2.1B RCSG-1A OTSG MK14-3 X-Y AXIS VESSEL NOZZLE MS MAIN STEAM INNER RADIUS Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-029 Sat 366464 CATEGORY: C-C ITEM: C3.10 Component Description OTSG MK152/153-TO-1 VESSEL INTEGRAL ATTACHMENT System

System Description

FW FEEDWATER Workscope Report No.

ISI MT-01 -042 Exam Results Work Request No.

Examination Remarks Sat 366464 Summary No.

Component ID Component Description C1.3.1.2 RCSG-1A OTSG MK152/153-TO-1 VESSEL INTEGRAL ATTACHMENT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-041 Sat 366464 System FW

System Description

FEEDWATER ITEM: C3.20 Component ID PIPING INTEGRAL ATTACHMENT Report No.

Exam Results MT-01-049 Unsat MT-01-053 Sat Component Description MSH-153 INTEGRAL ATTACHMENT Work Reauest No.

366476 366476 System MS

System Description

MAIN STEAM Examination Remarks Fabrication Blemishes - See MT-01-053 following Surface Prep.

Wednesday, January 16, 2002 CLASS:

2 Summary No.

C1.1.11 Component ID RCSG-1A Summary No.

C1.3.1.1 Component ID RCSG-1A Summary No.

C2.5.10 Workscope ISI ISI Page 38 of 61

S Florida Power A Progress Energy Com--any Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: C-C ITEM: C3.20 Summary No.

Component I D C2.5.30 PIPING INTEGRAL ATTACHMENT Workscope Report No.

Exam Results ISI MT-01-002 Sat Component Description FWH-148 INTEGRAL ATTACHMENT Work Request No.

Examination Remarks 366478 System FW

System Description

FEEDWATER Summary No.

Component ID Component Description System

System Description

C2.5.56 PIPING INTEGRAL EFH-540 INTEGRAL ATTACHMENT EF EMERGENCY FEEDWATER ATTACHMENT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01 -005 Sat 366478 CATEGORY: C-D ITEM: C4.40 Summary No.

Component ID Component Description System

System Description

C4.2.1 MSV-413 VALVE STUD STUD 97-01 MS MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks

]SI UT-01-021 Sat 366479 Summary No.

Component ID Component Description System

System Description

C4.2.2 MSV-413 VALVE STUD STUD 97-02 MS MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI UT-01-022 Sat 366479 Component ID MSV-413 VALVE STUD Component Description STUD 97-03 Ss m System Description MS MAIN STEAM Workscope Report No.

ISI UT-01-023 Summary No.

C2.1.174 Exam Results Work Request No.

Examination Remarks Sat 366479 CATEGORY: C-F-1 ITEM: AUG7.1 Component ID Component Description PIPING WELD DH-59C ELBOW-TO-PIPE System

System Description

DH DECAY HEAT Workscope Report !

AUG UT-01-0 Summary No.

C2.1.36 Lo.

Exam Results 13 Sat Component ID PIPING WELD Work Request No.

Examination Remarks 366494 Component Description DH-60E ELBOW-TO-PIPE System

System Description

DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG UT-01-014 Sat 366494 Wednesday, January 16, 2002 CLASS:

2 Summary No.

C4.2.3 Page 39 of 61

S Florida Power A Progress Energy Cmarrm, Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

2 CATEGORY: C-F-1 ITEM: AUG7.1

  • Component Description DH-86 PIPE-TO-ELBOW SSystem

System Description

DH DECAY HEAT Workscope Report P AUG UT-01 -0 No.

Exam Results

)15 Sat Work Request No.

Examination Remarks 366494 Summary No.

Component ID Component Description System

System Description

C2.1.57 PIPING WELD DH-97A FLANGE-TO-REDUCER DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG UT-01 -081 Sat 366487 Single-Sided Examination.

Summary No.

Component ID Component Description System

System Description

C2.1.581 PIPING WELD DH-1 04C TEE-TO-PIPE DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

Examination Remarks AUG UT-01-011 Sat 366487 Summary No.

Comoonent ID Component Description System

System Description

C2.1.582 PIPING WELD DH-104B TEE-TO-ELBOW DH DECAY HEAT Workscope Report No.

Exam Results Work Reauest No.

Examination Remarks AUG UT-01-012 Sat 366487 Component Description DH-63A PIPE-TO-PIPE System System Descnption DH DECAY HEAT Workscope Report No.

AUG UT-01-016 Exam Results Sat Work Request No.

Examination Remarks 366494 ITEM: C5.11 Component Description DH-27 PIPE-TO-TEE System

System Description

DH DECAY HEAT Work Request No.

Examination Remarks 366487 366487 PT Examination NQC Report #2001-0171 Component Description MU-94A REDUCER-TO-PIPE System

System Description

MU MAKE-UP Work Request No.

Examination Remarks 366494 366494 Wednesday, January 16, 2002 Summary No.

C2.1.551 Component ID PIPING WELD Summary No.

C2.1.817 Component ID PIPING WELD Component I D PIPING WELD Report No.

UT-01 -083 VE-01-005 Summary No.

C2.1.162 Workscope ISI ISI Summary No.

C2.1.212 Workscope ISI ISI Exam Results Sat Sat Component ID PIPING WELD Report No.

PT-01 -003 UT-01-020 Exam Results Sat Sat Page 40 of 61

S Florida Power A Progress Energy Cor*any CLASS:

2 CATEGORY: C-F-1 ITEM: C5.11 Summary No.

C2.1.45 Workscope ISI ISI Component ID PIPING WELD Report No.

UT-01-082 VE-01-004 Exam Results Sat Sat Component Description DH-21D PIPE-TO-ELBOW System

System Description

DH DECAY HEAT Work Request No.

Examination Remarks 366487 366487 PT Examination NQC Report #2001-0171 Summary No.

Component ID Component Description System

System Description

C2.1.507 PIPING WELD DH-39 FLANGE-TO-REDUCER DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01 -084 Sat 366487 Single-Sided Examination.

ISI VE-01-006 Sat 366487 PT Examination NQC Report #2001-0171 Summary No.

Component ID Component Description System

System Description

C2.1.526 PIPING WELD DH-46A FLANGE-TO-PIPE DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01 -008 Sat 366492 Single-Sided Examination.

ISI VE-01-012 Sat 366492 PT Examination NQC Report #2001-0105 Component I D PIPING WELD Report l' UT-01-0 VE-01-0 Report r UT-01 -0 VE-01-0 Report No.

UT-01-080 VE-01-003 0o.

Exam Results 09 Sat 13 Sat Component ID PIPING WELD No.

Exam Results 10 Sat 14 Sat Component ID PIPING WELD Exam Results Sat Sat Component Description DH-46B PIPE-TO-FLANGE SSystem HescriptTon DH DECAY HEAT Work Request No.

Examination Remarks 366492 Single-Sided Examination.

366492 PT Examination NQC Report #2001-0105 Component Description System

System Description

DH-74 REDUCER-TO-VALVE DH DECAY HEAT Work Request No.

Examination Remarks 366492 Single-Sided Examination.

366492 PT Examination NQC Report #2001-0105 Component Description DH-1 O0A FLANGE-TO-REDUCER Work Request No.

366487 366487 System

System Description

DH DECAY HEAT Examination Remarks Single-Sided Examination.

PT Examination NQC Report #2001-0171 Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

C2.1.527 Workscope ISI ISI Summary No.

C2.1.542 Workscope ISI ISI Summary No.

C2.1.600 Workscope ISI ISI Page 41 of61

C) Florida Power A Progress Energy Compare, CLASS:

2 CATEGORY: C-F-1 ITEM: C5.21 Summary No.

C2.1.1067 Workscope ISI ISI Component ID PIPING WELD Report No.

PT-01 -004 UT-01 -087 Exam Results Sat Sat Component Description MU-82 PIPE-TO-VALVE System

System Description

MU MAKE-UP Work Request No.

Examination Remarks 366493 366493 Single-Sided Examination.

Summary No.

Component ID Component Description System

System Description

C2.1.1084 PIPING WELD MU-86 VALVE-TO-REDUCER MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks SI PT-01 -005 Sat 366493 ISI UT-01-085 Sat 366493 Single-Sided Examination.

Summary No.

Component ID Component Description System

System Description

C2.1.1092 PIPING WELD MU-65B PIPE-TO-ELBOW MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI PT-01 -025 Sat 366494 ISI UT-01-074 Sat 366494 Component ID PIPING WELD Report No.

PT-01-001 UT-01-077 Exam Results Sat Sat Component ID PIPING WELD Report No.

Exam Results PT-01-002 Sat UT-01-086 Sat Component ID PIPING WELD Report No.

PT-01-007 UT-01 -076 Exam Results Sat Sat Component Description MU-88 PIPE-TO-VALVE Work Request No.

Examination Remarks 366494 366494 Single-Sided Examination.

Component Description MU-85-104 PIPE-TO-ELBOW Work Request No.

Examination Remarks 366494 366494 Component Description MU-153 VALVE-TO-PIPE m

ystem M

escrUpton MU MAKE-UP System

System Description

MU MAKE-UP System

System Description

MU MAKE-UP Work Request No.

Examination Remarks 366494 366494 Single-Sided Examination.

Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

C2.1.1096 Workscope ISI ISI Summary No.

C2.1.1127 Workscope ISI ISI Summary No.

C2.1.1223 Workscope ISI ISI Page 42 of 61

Florida Power A Progress Energy Cormry Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: C-F-1 ITEM: C5.21 Component I D PIPING WELD Report No.

PT-01-008 UT-01 -075 Exam Results Sat Sat Component Description MU-95K ELBOW-TO-PIPE System

System Description

MU MAKE-UP Work Request No.

Examination Remarks 366494 366494 Summary No.

Component I D Component Description System

System Description

C2.1.1351 PIPING WELD MU-90-214 PIPE-TO-TEE MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks IS1 PT-01 -035 Sat 366487 ISI UT-01-078 Sat 366487 Summary No.

Component ID Component Description System

System Description

C2.1.1490 PIPING WELD DH-101F TEE-TO-PIPE DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI UT-01-079 Sat 366487 ISI VE-01-002 Sat 366487 PT Examination NOC Report #2001-0171 Component Description MU-44D ELBOW-TO-FLANGE m

ystem M

esc-U pon MU MAKE-UP Work Request No.

Examination Remarks 366487 Single-Sided Examination.

366487 PT Examination NQC Report #2001-0152 Component Description System

System Description

MU-32D ELBOW-TO-FLANGE MU MAKE-UP Work Request No.

Examination Remarks 366493 366493 Single-Sided Examination.

Component Description MU-393 PENETRATION-TO-PIPE System

System Description

MU MAKE-UP Work Request No.

Examination Remarks 366475 366475 Wednesday, January 16, 2002 CLASS:

2 Summary No.

C2.1.1229 Workscope ISI ISI Component ID PIPING WELD Report No.

UT-01-092 VE-01-007 Summary No.

C2.1.2073 Workscope ISI ISI Summary No.

C2.1.2078 Workscope ISI ISI Exam Results Sat Sat Component ID PIPING WELD Report No.

PT-01 -006 UT-01-088 Exam Results Sat Sat Component ID PIPING WELD Summary No.

02.1.2084 Workscope ISI ISI Report No.

PT-01-031 UT-01-122 Exam Results Sat Sat Page 43 of 61

S Florida Power A Progress Energy Company Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: C-F-1 ITEM: C5.30 Component Description 3497-MU-18 VALVE-TO-PIPE System

System Description

MU MAKE-UP Workscope Report No.

IS1 VE-01 -008 Exam Results Work Request No.

Sat 366487 Examination Remarks PT Examination NQC Report #2001-0153 ITEM: C5.41 Summary No.

Component ID Component Description System

System Description

C2.1.1345 PIPING WELD MU-73A PIPE-TO-COUPLING MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-009 Sat 366487 PT Examination NQC Report #2001-0154 CATEGORY: C-F-2 ITEM: C5.51 Summary No.

Component ID Component Description System

System Description

C2.1.1 PIPING WELD MS-1 NOZZLE-TO-ELBOW MS MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01 -039 Sat 366464 ISI UT-01-127 Sat 366464 Component Description MS-6A PIPE-TO-ELBOW MS MSystem Description MS MAIN STEAM Work Request No.

Examination Remarks 366478 366478 Component Description MS-288 ELBOW-TO-PIPE System

System Description

MS MAIN STEAM Work Request No.

Examination Remarks 366478 366478 Component Description MS-287 PIPE-TO-VALVE System

System Description

MS MAIN STEAM Work Request No.

Examination Remarks 366478 366478 Single-Sided Examination.

Wednesday, January 16, 2002 CLASS:

2 Summary No.

C2.1.1360 Component I D PIPING WELD Component ID PIPING WELD Report No.

MT-01-008 UT-01-017 Exam Results Sat Sat Component I D PIPING WELD Summary No.

C2.1.107 Workscope ISI ISI Summary No.

C2.1.108 Workscope ISI iSI Summary No.

C2.1.109 Workscope ISI ISI Report No.

MT-01 -009 UT-01 -018 Exam Results Sat Sat Component ID PIPING WELD Report No.

MT-01-006 UT-01-019 Exam Results Sat Sat Page 44 of 61

Florida Power A Progress Energy (omrany Inservice Inspection Report Interval 3 1 Period 1 / Refuel Cycle 12 CATEGORY: C-F-2 ITEM: C5.51 Component I D PIPING WELD Report No.

Exam Results UT-01-066 Sat Component Description MS-1 0 NOZZLE-TO-ELBOW System MS

System Description

MAIN STEAM Work Request No.

Examination Remarks 366464 Summary No.

Component ID Component Description System

System Description

C2.1.112 PIPING WELD MS-12 PIPE-TO-ELBOW MS MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01 -047 Sat 366476 ISI UT-01 -062 Sat 366476 Summary No.

Component ID Component Description System

System Description

C2.1.113 PIPING WELD MS-15A PIPE-TO-ELBOW MS MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-050 Sat 366476 iSI UT-01-064 Sat 366476 Summary No.

Component ID Component Description System

System Description

C2.1.123 PIPING WELD FW MK123 TO FW MK127 PIPE-TO-CAP FW FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01 -040 Sat 366464 ISI UT-01 -025 Sat 366464 Report No.

MT-01 -048 MT-01-052 UT-01 -063 Component ID PIPING WELD 0o.

Exam Results 43 Sat 24 Sat Component ID PIPING WELD Exam Results Unsat Sat Sat Component Descridtion FW-10 ELBOW-TO-TEE Work Request No.

Examination Remarks 366464 366464 Component Description FW-102C PIPE-TO-ELBOW Work Request No.

Examination Remarks 366476 366476 366476 W

ystem F

esEriWAT Rl FW FEEDWATER System

System Description

FW FEEDWATER Wednesday, January 16, 2002 CLASS:

2 Summary No.

C2.1.111 Workscope ISI Report N MT-01-0 UT-01-0 Summary No.

C2.1.124 Workscope ISI ISI Summary No.

C2.1.126 Workscope ISI ISI ISI Page 45 of 61

'Florida Power A Progress Energy Corn pa' Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: C-F-2 ITEM: C5.51 Component ID PIPING WELD Report No.

MT-01-011 UT-01 -035 Exam Results Sat Sat Component Description FW-333 VALVE-TO-ELBOW System

System Description

FW FEEDWATER Work Request No.

Examination Remarks 366478 366478 Single-Sided Examination.

Summary No.

Component ID Component Description System

System Description

C2.1.128 PIPING WELD FW-330 ELBOW-TO-PIPE FW FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-004 Sat 366478 ISI UT-01-072 Sat 366478 Summary No.

Component ID Component Description System

System Description

C2.1.129 PIPING WELD FW-329 ELBOW-TO-PIPE FW FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-003 Sat 366478 ISI UT-01 -073 Sat 366478 Component ID PIPING WELD Report No.

Exam Results MT-01-014 Sat UT-01 -065 Sat Component ID PIPING WELD Report No.

Exam Results MT-01-015 Sat UT-01-026 Sat Component I D PIPING WELD Report No.

MT-01-010 UT-01-027 Exam Results Sat Sat Component Description FW-178E ELBOW-TO-PIPE Work Request No.

Examination Remarks 366464 366464 Component Description FW-178B PIPE-TO-ELBOW Work Request No.

Examination Remarks 366464 366464 Component Description FW-178A ELBOW-TO-PIPE Sse

  • System Descnption EF EMERGENCY FEEDWATER TO OTSG "A" System EF System EF

System Description

EMERGENCY FEEDWATER TO OTSG "A"

System Description

EMERGENCY FEEDWATER TO OTSG "A" Work Request No.

Examination Remarks 366464 366464 Wednesday, January 16, 2002 CLASS:

2 Summary No.

C2.1.127 Workscope ISI ISI Summary No.

C2.1.143 Workscope ISI ISI Summary No.

C2.1.144 Workscope ISI ISI Summary No.

C2.1.145 Workscope ISI ISI Page 46 of 61

S Florida Power A Progress Energy Cotrrany CLASS:

2 CATEGORY: C-F-2 ITEM: C5.51 Component ID PIPING WELD

01.

Exam Results 44 Sat 30 Sat Component Description FW-177A PIPE-TO-ELBOW System EF

System Description

EMERGENCY FEEDWATER TO OTSG "A" Work Request No.

Examination Remarks 366476 366476 Summary No.

Component ID Component Description System

System Description

C2.1.147 PIPING WELD FW-175A PIPE-TO-ELBOW EF EMERGENCY FEEDWATER TO OTSG "A' Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-045 Sat 366464 iSI UT-01 -031 Sat 366464 Summary No.

Component I D Component Description System

System Description

C2.1.319 PIPING WELD FW-9 REDUCER-TO-PIPE FW FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-016 Sat 366464 ISI UT-01-090 Sat 366464 ITEM: C5.81 Component I D PIPING WELD Exam Results Sat Component ID PIPING WELD Component Description FW-1 13D WELDOLET-TO-PIPE System FW

System Description

FEEDWATER Work Request No.

Examination Remarks 366479 Component Description MS-6F PIPE-TO-SWEEPOLET System MS

System Description

MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI MT-01-007 Sat 366478 CATEGORY: C-H ITEM:

Summary No.

Component ID C7.100.10 SFRS-1 SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01 -035 Sat C7.00.CH Component Description SF Pen. 347 Expansion Chamber Work Request No.

360312 System

System Description

SF SPENT FUEL Examination Remarks VT-2 Examination Using SP-206 Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

C2.1.146 Workscope ISI ISI Report N MT-01 -0 UT-01-0, Summary No.

C2.1.372 Workscope ISI Summary No.

C2.3.14 Report No.

MT-01-001 Page 47 of 61

Florida Power A Progresn Eergy Corm*y Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: C-H ITEM: C7.00.CH Component ID DHP-1B SYSTEM PRESSURE TEST Component Description Decay Heat Pump 1B System

System Description

DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

ISI VE-01-036 Sat 360315 Examination Remarks VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.14 MUP-1B SYSTEM Make-Up Pump 1B MU MAKE-UP PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01 -037 Sat 360320 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.15 MUP-lC SYSTEM Make-Up Pump 1C MU MAKE-UP PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-038 Sat 360321 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.16 CFT-1B SYSTEM Core Flood Tank 1 B CF CORE FLOOD PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01 -079 Sat 360328 VT-2 Examination Using SP-206 Component ID BSP-1B SYSTEM PRESSURE TEST Component Description Building Spray Pump 1B System BS

System Description

BUILDING SPRAY Workscope Report No.

Exam Results ISI VE-01-039 Sat Summary No.

Component ID C7.100.19 MUP-1A SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-090 Sat Summary No.

Component ID C7.100.21 SW SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01 -088 Sat Work Request No.

Examination Remarks 360330 VT-2 Examination Using SP-206 Component Description Sstem

System Description

Make-Up Pump 1A MU MAKE-UP Work Request No.

Examination Remarks 360319 VT-2 Examination Using SP-206 Component Description System

System Description

LETDOWN COOLERS SW SUPPLY/

SW NUCLEAR CLOSED CYCLE RETURN COOLING Work Request No.

Examination Remarks 366462 VT-2 Examination Using SP-206 Component ID SWV-35 SYSTEM PRESSURE TEST Component Description SW TO AHFIA System

System Description

SW NUCLEAR CLOSED CYCLE COOLING Workscope Report No.

Exam Results Work Request No.

ISI VE-01-015 Sat 366462 Examination Remarks VT-2 Examination Using SP-206 Wednesday, January16, 2002 CLASS:

2 Summary No.

C7.100.12 Summary No.

C7.100.18 Summary No.

C7.100.22 Page 48 of 61

SFlorida Power A Progress Energy Gon-any Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

2 CATEGORY: C-H ITEM: C7.00.CH Component ID DHV-5 SYSTEM PRESSURE TEST Report No.

VE-01 -010 Component Description "A" TRAIN DH TO RB Exam Results Work Request No.

Sat 367295 System

System Description

DH DECAY HEAT Examination Remarks

'T-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.24 DHV-6 SYSTEM "B" TRAIN DH TO RB DH DECAY HEAT PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-070 Sat 367296 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.25 DHV-4 SYSTEM DH DROPLINE TO DHP-1A DH DECAY HEAT PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-071 Sat 366468 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.26 DHV-4 SYSTEM DH DROPLINE TO DHP-1B DH DECAY HEAT PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-072 Sat 367296 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.27 RCSG-1A SYSTEM INTERMEDIATE BUILDING MAIN STEAM MS MAIN STEAM PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-001 Sat 366478 VT-2 Examination Using SP-206 Summary No.

Component ID C7.100.28 FWV-44 SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-077 Sat Summary No.

Component ID C7.100.29 FWV-43 SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-078 Sat Summary No.

Component ID C7.100.30 EFV-56 SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-080 Sat Component Description EF TO RCSG-1A Work Request No.

E 364803 Component Description EF TO RCSG-1B Work Request No.

E 368652 Component Description "A" TRAIN EF (EFP-2)

Work Request No.

N/A System EF System DescriptiYn EMERGENCY FEEDWATER Examination Remarks (T-2 Examination Using SP-206 System EF

System Description

EMERGENCY FEEDWATER Examination Remarks IT-2 Examination Using SP-206 System EF

System Description

EMERGENCY FEEDWATER

xamination Remarks

/T-2 Examination Using SP-206 Wednesday, January 16, 2002 Summary No.

C7.100.23 Workscope iSI Page 49 of 61

Vj Florida Power A%

Progress Energy Crmonw.,

Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

2 CATEGORY: C-H ITEM: C7.00.CH Component ID EFV-55 SYSTEM PRESSURE TEST Workscope Report No.

]SI VE-01-081 Exam Results Sat Component Description "B" TRAIN EF (EFP-2)

Work Request No.

E N/A V

System

System Description

EF EMERGENCY FEEDWATER Examination Remarks

'T-2 Examination Using SP-206 Summary No.

Component I D Component Description System

System Description

C7.100.32 EFV-58 SYSTEM "A' TRAIN EF (EFP-3)

EF EMERGENCY FEEDWATER PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-084 Sat N/A VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.33 EFV-57 SYSTEM

'B" TRAIN EF (EFP-3)

EF EMERGENCY FEEDWATER PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-085 Sat N/A VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

C7.100.37 DHV-91 SYSTEM DHV-91 TO DHV-93 DH DECAY HEAT PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-018 Sat 367295 VT-2 Examination Using SP-206 Summary No.

C7.100.38 Component I D SWV-37 SYSTEM PRESSURE TEST Workscope Report No.

ISI VE-01-016 Exam Results Sat Summary No.

Component ID C7.100.39 SWV-39 SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-014m17 Sat Summary No.

Component ID C7.100.6 SW SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-089 Sat Component Description SW TO AHF-1B Work Request No.

E 366462 V

Component Description SW TO AHF-1C Work Request No.

366462 Component Descriptio SW Cooling for Contro Mechanisms Work Request No.

366462 System SW

System Description

NUCLEAR CLOSED CYCLE COOLING xamination Remarks T-2 Examination Using SP-206 System

System Description

SW NUCLEAR CLOSED CYCLE COOLING Examination Remarks VT-2 Examination Using SP-206 n

stem

System Description

I1 Rod Drive SW NUCLEAR CLOSED CYCLE COOLING Examinatic VT-2 Exarr n Remarks ination Using SP-206 Wednesday, January 16, 2002 Summary No.

C7.100.31 Page 50 of 61

S Florida Power A Progress Energy Comav9ny Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

2 CATEGORY: F-A ITEM: F1.20A Component ID COMPONENT SUPPORT Component Descdption RESTRAINT System

System Description

DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-177 Sat 366487 Summary No.

Component ID Component Description System

System Description

DHR-22 COMPONENT SUPPORT STRUT DH DECAY HEAT Workscope Report No.

Exam Results Work Reauest No.

Examination Remarks ISI VT-01-181 Sat 366487 Summary No.

Component ID Component Description System

System Description

DHR-29 COMPONENT SUPPORT STRUT DH DECAY HEAT Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-247 Sat 366494 NQC Report #2001-0024 Summary No.

Component ID Component Description System

System Description

MUH-509 COMPONENT SUPPORT ROD MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -237 Sat 366494 NQC Report #2001-0024 Summary No.

Component ID Component Description System

System Description

MUH-516 COMPONENT SUPPORT ROD MU MAKE-UP Workscope Report No.

Exam Results ISI VT-01-179 Sat Summary No.

MUH-806 Workscope ISI Summary No.

SWH-281 Component I D COMPONENT SUPPORT Report No.

Exam Results VT-01 -236 Sat Component ID COMPONENT SUPPORT Work Request No.

Examination Remarks 366494 Commonent Description STRUT Work Request No.

Examination Remarks 366494 Component Description RIGID ROD System

System Description

MU MAKE-UP System SW

System Description

NUCLEAR CLOSED CYCLE COOLING Workscope Report No.

Exam Results ISI VT-01-186 Sat Summary No.

Component ID SWR-316 COMPONENT SUPPORT Work Request No.

Examination Remarks 366462 Component Description STRUT SW

System Description

NUCLEAR CLOSED CYCLE COOLING Workscope Report No.

ISI VT-01-191 Exam Results Work Request No.

Examination Remarks Sat 366462 Wednesday, January 16, 2002 Summary No.

DHH-547 Page 51 of 61

Florida Power A Progress Energy CGomrrsny Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No:

SWR-324 CATEGORY: F-A ITEM: F1.20A Component ID

-Component Description COMPONENT SUPPORT STRUT Workscope Report No.

Exam Results ISI VT-01-192 Sat System

System Description

SW NUCLEAR CLOSED CYCLE COOLING Work Request No.

Examination Remarks 366462 ITEM: F1.20B Summary No.

Component ID Component Description System

System Description

MUH-884 COMPONENT SUPPORT ANCHOR MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-180 Sat 366494 Summary No.

Component ID Component Description System

System Description

MUH-977 COMPONENT SUPPORT RESTRAINT MU MAKE-UP Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-083 Sat 366494 Summary No.

Component ID Component Description System

System Description

SWH-382 COMPONENT SUPPORT U-BOLT SW NUCLEAR CLOSED CYCLE COOLING Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VT-01-188 Sat 366462 ITEM: F1.20C Summary No.

DHH-543 Component ID Component Description COMPONENT SUPPORT SPRING CAN Workscope Report No.

ISI VT-01-178 Sstem

System Description

DH DECAY HEAT Exam Results Work Request No.

Examination Remarks Sat 366487 Summary No.

DHH-549 Component ID Component Description COMPONENT SUPPORT SPRING CAN Workscope Report No.

ISI VT-01-176 System

System Description

DH DECAY HEAT Exam Results Work Request No.

Examination Remarks Sat 366487 Summary No.

EFH-115 Component ID Component Description COMPONENT SUPPORT SPRING CAN System

System Description

EF EMERGENCY FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-187 Sat 366476 Wednesday, January16, 2002 CLASS:

2 Page 52 of 61

Florida Power A Progress Energy Camrany Inservice Inspection Report Interval 3 / Period 1 1 Refuel Cycle 12 CATEGORY: F-A ITEM: F1.20C Component ID COMPONENT SUPPORT Component Description SPRING CAN System

System Description

FW FEEDWATER Workscope Report No.

Is]

VT-01-257 Exam Results Work Request No.

Examination Remarks Sat 366464 Summary No.

Component ID Component Description System

System Description

FWH-75 COMPONENT SUPPORT SPRING CAN FW FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-194 Sat 366478 Summary No.

Component ID Component Description System

System Description

FWH-80 COMPONENT SUPPORT SPRING CAN FW FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-193 Sat 366478 Summary No.

Component ID Component Description System

System Description

MSH-153 COMPONENT SUPPORT SPRING CAN MS MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-091 Sat 367070 / 366476 NQC Report #2001-0283 Summary No.

Cc MSH-154 C(

Workscope Report No.

ISI VE-01-092 Summary No.

Cc MUH-517 C

Workscope Report No.

ISI VT-01 -250 rmponent ID

)MPONENT SUPPORT Component Description SPRING CAN Exam Results Work Request No.

Examination Remarks Sat 367070 / 366476 NQC Report #2001-0284

)mponent ID Component Description OMPONENT SUPPORT SPRING CAN Exam Results Sat MS System MU

System Description

MAIN STEAM

System Description

MAKE-UP Work Request No.

Examination Remarks 366492 NOC Report #2001-0107 ITEM: F1.40 Component ID Component Description COMPONENT SUPPORT SUPPORT Workscope Report No.

ISI VT-01-175 System

System Description

DH DECAY HEAT Exam Results Work Request No.

Examination Remarks Sat 366487 Wednesday, January 16, 2002 CLASS:

2 Summary No.

FWH-134 Summary No.

DHP-1A Page 53 of 61

Florida Power A Progress Energy rComrny Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: D-A ITEM: D1.10 Summary No.

D1.100.10 Workscope Report i' ISI VE-01-0 Component ID MUV-50 SYSTEM PRESSURE TEST Jo.

Exam Results 40 Sat Component DescriPtion LETDOWN ISOLATION SYSTEM COMPONENTS Work Request No.

360321

-- System MU

System Description

MAKE-UP Examination Remarks VT-2 Examination Using SP-206 Summary No.

Component I D Component Description System

System Description

D1.100.15 CHP-1A SYSTEM CH COOLING FOR CONTROL COMPLEX CH CHILLED WATER PRESSURE TEST EFIC ROOMS Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01 -042 Sat 360336 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.16 PEN-321 SYSTEM SW SUPPLY / RETURN LETDOWN SW NUCLEAR CLOSED CYCLE PRESSURE TEST COOLERS COOLING Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VE-01-043 Sat 368985 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.17 SWP-1A SYSTEM SWP-1A SYSTEM COMPONENTS SW NUCLEAR CLOSED CYCLE PRESSURE TEST COOLING Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VE-01-044 Sat 368989 VT-2 Examination Using SP-206 Summary No.

D1.100.21 Workscope Report N iSI VE-01-0G Component ID EFP-1A SYSTEM PRESSURE TEST

10.

Exam Results 48 Sat Component Descrption SW TO EFP-1 Work Request No.

368985 Sse System uesciption SW NUCLEAR CLOSED CYCLE COOLING Examination Remarks VT-2 Examination Using SP-206 Component ID Component Description CCHE-1A SYSTEM SW TO CONTROL COMPLEX HEAT PRESSURE TEST EXCHANGERS Report No.

Exam Results Work Request No.

Examination F VE-01-051 Sat 368985 VT-2 Examina Component ID Component Description SWP-1C SYSTEM SWP-1C SYSTEM COMPONENTS PRESSURE TEST Report No.

VE-01 -052 Exam Results Work Request No.

Sat 368985 Component I D RWP-1 SYSTEM PRESSURE TEST Workscope Report No.

ISI VE-01-054 Exam Results Sat System SW remarks tion Using SP-206 System SW

System Description

NUCLEAR CLOSED CYCLE COOLING

System Description

NUCLEAR CLOSED CYCLE COOLING Examination Remarks VT-2 Examination Using SP-206 Component Description RW TO SW HEAT EXCHANGERS Work Request No.

368992 System RW

System Description

NUCLEAR SERVICES SEA WATER Examination Remarks VT-2 Examination Using SP-206 Wednesday, January 16, 2002 CLASS:

3 Summary No.

D1.100.24 Workscope ISI Summary No.

D1.100.25 Workscope ISI Summary No.

D1.100.27 Page 54 of 61

S Florida Power A Progress Energy Comrrn.

Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

3 CATEGORY: D-A ITEM: D1.10 Summary No.

Component ID QComponent Description System

System Description

D1.100.30 RWP-3B SYSTEM RWP-3B TO DCHE-1B RW NUCLEAR SERVICES SEA PRESSURE TEST WATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-057 Sat 368995 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.31 RWP-2B SYSTEM RWP-2B TO RWV-35 RW NUCLEAR SERVICES SEA PRESSURE TEST WATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01 -058 Sat 368996 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.33 DHV-93 SYSTEM DECAY HEAT TO RC (RCT-1)

DH DECAY HEAT PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01 -011 Sat 367295 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.36 EFP-3 SYSTEM EFP-3 DIESEL JACKET COOLING DJ DIESEL JACKET COOLANT PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-060 Sat 368999 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.37 EGDG-1A SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01 -068 Sat Summary No.

Component ID D1.100.38 EGDG-1B SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-069 Sat Summary No.

Component ID D1.100.39 EFP-2 SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-061 Sat Summary No.

Component ID D1.100.40 EFV-11 SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01 -082 Sat EGDG-1A JACKET COOLING Work Request No.

368919 DJ DIESEL JACKET COOLANT Examination Remarks VT-2 Examination Using SP-206 Component Description EGDG-1B JACKET COOLANT Work Request No.

368922 System DJ

System Description

DIESEL JACKET COOLANT Examination Remarks VT-2 Examination Using SP-206 Component Description EFP-2 EF SYSTEM COMPONENTS Work Request No.

N/A System EF

System Description

EMERGENCY FEEDWATER Examination Remarks VT-2 Examination Using SP-206 Compnent Description EFP-2 EF SYSTEM COMPONENTS Work Request No.

N/A System EF

System Description

EMERGENCY FEEDWATER Examination Remarks VT-2 Examination Using SP-206 Wednesday, January 16, 2002 Page 55 of 61

Florida Power A Progress Energy Coreramr Inservice Inspection Report Interval 3 / Period 1 1 Refuel Cycle 12 CATEGORY: D-A ITEM: D1.10 Summary No.

Component ID D1.100.41 EFV-32 SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-083 Sat Component Description EFP-2 EF SYSTEM COMPONENTS Work Request No.

N/A System

System Description

EF EMERGENCY FEEDWATER Examination Remarks VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.42 EFP-3 SYSTEM EFP-3 EF SYSTEM COMPONENTS EF EMERGENCY FEEDWATER PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-062 Sat N/A VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.43 EFV-14 SYSTEM EFP-3 EF SYSTEM COMPONENTS EF EMERGENCY FEEDWATER PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-086 Sat N/A VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.44 EFV-33 SYSTEM EFP-3 EF SYSTEM COMPONENTS EF EMERGENCY FEEDWATER PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-087 Sat N/A VT-2 Examination Using SP-206 ITEM: D1.20 Component I D SWH-557 PIPING ATTACHMENT Workscope Report No.

ISI VT-01-245 Component Description INTEGRAL ATTACHMENT Exam Results Work Request No.

Sat 366492 System SW

System Description

NUCLEAR CLOSED CYCLE COOLING Examination Remarks NQC Report #2001-0107 ITEM: D1.20B Component ID DCT-1A VESSEL ATTACHMENT Component Description INTEGRAL ATTACHMENT System

System Description

DC DECAY HEAT CLOSED CYCLE COOLING Workscope Report No.

Exam Results Work Request No.

ISI VT-01-240 Sat 366487 Examination Remarks NQC Report #2001-0031 CATEGORY: D-B ITEM: D1.10 Summary No.

Component ID D1.100.18 SWP-1B SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-045 Sat Component Description SWP-1 B SYSTEM COMPONENTS Work Request No.

368990 System

System Description

SW NUCLEAR CLOSED CYCLE COOLING Examination Remarks VT-2 Examination Using SP-206 Wednesday, January 16, 2002 CLASS:

3 Summary No.

D2.5.7 Summary No.

D2.5.87 Page 56 of 61

S Florida Power A Progress Energy Cornr, n

CLASS:

3 CATEGORY: D-B ITEM: D1.10 Summary No.

D1.100.19 Workscope Report I' ISI VE-01-0 Component I D PEN-368 SYSTEM PRESSURE TEST No.

Exam Results 46 Sat Component Description SW SUPPLY / RETURN-TO-RB FANS Work Request No.

368985 System SW

System Description

NUCLEAR CLOSED CYCLE COOLING Examination Remarks VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D-1.100.20 MUP-1A SYSTEM SW-TO-MUP-1A SW NUCLEAR CLOSED CYCLE PRESSURE TEST COOLING Workscope Report No.

Exam Results Work Reauest No.

Examination Remarks ISI VE-01-047 Sat 368985 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.26 DOV-116 SYSTEM DO TO RW PUMPS DO DOMESTIC WATER PRESSURE TEST Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-053 Sat 368991 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.28 RWP-2A SYSTEM RWP-2A-TO-RWV-38 RW NUCLEAR SERVICES SEA PRESSURE TEST WATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-055 Sat 368993 VT-2 Examination Using SP-206 Summary No.

Component ID D1.100.29 RWP-3A SYSTEM PRESSURE TEST Workscope Report No.

Exam Results ISI VE-01-056 Sat Component Description RWP-3A TO DCHE-1A Work Request No.

368994 Sse yS tem uescnipuon RW NUCLEAR SERVICES SEA WATER Examination Remarks VT-2 Examination Using SP-206 Component ID DCT-1 SYSTEM PRESSURE TEST Component Description "A" TRAIN DC SYSTEM System DC

System Description

DECAY HEAT CLOSED SYSLE COOLING Workscope Report r, ISI VE-01-0 Summary No.

D1.100.35 Workscope Report ISI VE-01-C Exam Results Work Request No.

Sat 368997 Component ID DCT-1B SYSTEM PRESSURE TEST No.

Exam Results 59 Sat Component Description "B"TRAIN DC SYSTEM Work Request No.

E 368998 V

Examination Remarks VT-2 Examination Using SP-206 SCstem DC

System Description

DECAY HEAT CLOSED SYSLE COOLING xamination Remarks T-2 Examination Using SP-206 Wednesday, January 16, 2002 Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 Summary No.

D1.100.34 Page 57 of 61

SFlorida Power A Progress Energy Comrsný,,

Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

3 CATEGORY: D-C ITEM: D1.10 Summary No.

Component ID Component Description System

System Description

D1.100.22 SFHE-1A ALL SW TO SFHE-1A SW NUCLEAR CLOSED CYCLE PRESSURE RETAINING COOLING COMPONENTS Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VE-01 -049 Sat 368985 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.23 SFHE-1 B ALL SW TO SFHE-1 B SW NUCLEAR CLOSED CYCLE PRESSURE RETAINING COOLING COMPONENTS Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-050 Sat 368985 VT-2 Examination Using SP-206 Summary No.

Component I D Component Description System

System Description

D1.100.5 SFP-1 A ALL PRESSURE SFP-1A SYSTEM COMPONENTS SF SPENT FUEL RETAINING COMPONENTS Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VE-01-063 Sat 360312 VT-2 Examination Using SP-206 Summary No.

Component ID Component Description System

System Description

D1.100.6 SFP-1B ALL PRESSURE SFP-1B SYSTEM COMPONENTS SF SPENT FUEL RETAINING COMPONENTS Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VE-01-064 Sat 360313 VT-2 Examination Using SP-206 CATEGORY: F-A ITEM: F1.30A Summary No.

Component ID Component Description DCH-150 COMPONENT SUPPORT ROD Workscope Report No.

Exam Results Work Reauest No.

Examination Remarks ISI VT-01 -242 Sat 366487 NQC Report #2001-0028 Summary No.

Component ID Component Description EFH-133 COMPONENT SUPPORT ROD Workscope Report No.

ISI VT-01-071 Summary No.

RWH-48 System DC

System Description

DECAY HEAT CLOSED CYCLE COOLING System

System Description

EF EMERGENCY FEEDWATER Exam Results Work Request No.

Examination Remarks Sat 366479 Component I D Component Description COMPONENT SUPPORT ROD System

System Description

RW NUCLEAR SERVICES SEA WATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -243 Sat 366487 Wednesday, January 16, 2002 Page 58 of 61

SFlorida Power A Progress Energy to

-any Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CLASS:

3 CATEGORY: F-A ITEM: F1.30A Summary No.

RWH-77 Component ID COMPONENT SUPPORT Workscope Report No.

Exam Results ISI VT-01-248 Sat Component Description STRUT Work Request No.

E 366494 System

System Description

RW NUCLEAR SERVICES SEA WATER Examination Remarks QC Report #2001-0025 Summary No.

Component ID Component Description System

System Description

SWH-177 COMPONENT SUPPORT ROD SW NUCLEAR CLOSED CYCLE COOLING Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-249 Sat 366494 NQC Report #2001-0026 Summary No.

Component ID Component Description System

System Description

SWH-52 COMPONENT SUPPORT ROD SW NUCLEAR CLOSED CYCLE COOLING Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-244 Unsat 366494 NQC Report #2001-0103, Component is Operable WR370460 written to correct.

Summary No.

Component I D Component Description System

System Description

SWR-1 11 COMPONENT SUPPORT STRUT SW NUCLEAR CLOSED CYCLE COOLING Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01 -082 Sat 366494 Component I D COMPONENT SUPPORT Workscope Report No.

Exam Results ISI VT-01-081 Sat Component ID COMPONENT SUPPORT Workscope Report No.

iSI VT-01 -246 Component Description STRUT Work Request No.

Examination Remarks 366494 Component Description STRUT Exam Results Work Request No.

Sat 366494 System System uescription SW NUCLEAR CLOSED CYCLE COOLING System SW

System Description

NUCLEAR CLOSED CYCLE COOLING Examination Remarks NQC Report #2001-0104 ITEM: F1.30C Component I D Component Description COMPONENT SUPPORT SPRING CAN Workscope Report No.

Exam Results Work Request No.

ISI VT-01-241 Sat 366487 System DC

System Description

DECAY HEAT CLOSED CYCLE COOLING Examination Remarks NQC Report #2001-0029 Wednesday, January16, 2002 Summary No.

SWR-199 Summary No.

SWR-492 Summary No.

DCH-109A Page 59 of 61

S Florida Power A Progress Energy Com.s,-ny Inservice Inspection Report Interval 3 / Period 1 / Refuel Cycle 12 CATEGORY: F-A ITEM: F1.30C Component ID Component Description COMPONENT SUPPORT RESTRAINT Report P VT-01-1 0o.

Exam Results Work Request No.

E 95 Sat 366478 System EF

System Description

EMERGENCY FEEDWATER Examination Remarks Summary No.

Component I D Component Description System

System Description

MSH-178 COMPONENT SUPPORT SPRING CAN MS MAIN STEAM Workscope Report No.

Exam Results Work Request No.

Examination Remarks SI VT-01-001 Sat 366479 ITEM: F1.40 Summary No.

Component ID Component Description System

System Description

EFH-615 COMPONENT SUPPORT ANCHOR EF EMERGENCY FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks iSI VT-01-182 Sat 366495 NQC Report #2001-0129 Summary No.

Component I D Component Description System

System Description

EFH-616 COMPONENT SUPPORT ANCHOR EF EMERGENCY FEEDWATER Workscope Report No.

Exam Results Work Request No.

Examination Remarks ISI VT-01-183 Sat 366495 NQC Report #2001-0130 CLASS:

AUG CATEGORY: AUG ITEM: AUG7.3 Component I D Component Description MUV-37 THERMAL B-2 HPI THERMAL SLEEVE SLEEVE Report No.

UT-01-041 VE-01-029 Exam Results Eval Sat System MU

System Description

MAKE-UP Work Request No.

Examination Remarks 366468 366468 RT Examination NQC Report #2001-0248 ITEM: AUG7.5 Component ID Component Description RCT-1 PRESSURIZER VENT NOZZLE MK # 78 Workscope Report No.

AUG VT-01-238 Exam Results Sat System

System Description

RC REACTOR COOLANT Work Request No.

Examination Remarks 366464 Wednesday, January 16, 2002 CLASS:

3 Summary No.

EFH-53 Workscope ISI Summary No.

XO.3.4 Workscope AUG AUG Summary No.

X009 Page 60 of 61

Florida Power A Progress Energy Cn*amny Inservice Inspection Report Interval 3 / Period 1 1 Refuel Cycle 12 CLASS:

AUG CATEGORY: AUG ITEM: AUG7.6 Component I D Component Description RCP-1A REACTOR COOLANT PUMP FLYWHEEL Workscope Report No.

Exam Results AUG VE-01-030 Sat System

System Description

RC REACTOR COOLANT Work Request No.

Examination Remarks 366460 Summary No.

Component I D Component Description System

System Description

B5.10.3 RCP-1B REACTOR COOLANT PUMP FLYWHEEL RC REACTOR COOLANT Workscope Report No.

Exam Results Work Reauest No.

Examination Remarks AUG VE-01 -031 Sat 366461 Wednesday, January 16, 2002 Summary No.

B5.10.1 Page 61 of 61

ATTACHMENT 2 NIS-2 Owner's Reports of Repair or Replacement for ASME Class 1 and Class 2 Components (86 Pages)

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/09/2001

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnRIC PFRFnRmpIf RV (NAMFII rPAI41lR ARPAZrANI7ATIrlM P

I 1

-11 I1 A I

-R NI IM

-rF,TC

3.

FLORIDA POWER CORPORATION WR 368411 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

DECAY HEAT REMOVAL (DH)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSIB31.1 1967 N/A /

N/A APPLICABLE EDITION OF SECTION Xl UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 720136 N/A DHH-17 N/A REPLACEMENT X

i

+

i I

T I

I - rI

+

+

t I

I-r I-FI t

I-F-

.4-

.4-F F

-f F

4

.4-1 F

+

F I-F-F F

I t

T F

IF

F F

t t

t F

F F

I F

-I-F t-F-I i

I I

I I

I j

i

-I t-F -

I___________

I i 4 i F i t-F F

F I

I F

F I.

i I*

t t-t-F F

1 4

F t

IF I __________________________________

[ _______________________________________

.1 _____________________

1 ___________________________________

.

RET: Life of Rant RESP: Nudear Enoineerina 900 431 P.,, 111QA

NIS-2 CONTINUATION WR# 368411 Page 2

of 2

DESCRIPTION OF WORK REPLACED 2.5"X5" POWER PIPING SNUBBER 730211 WITH LIKE-FOR-LIKE SNUBBER 720136, WHICH WAS REBUILT UNDER WR 369621.

8 TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 9 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

CERTIFICATE OF INSPECTION i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of naeinspcre me J=

HARTFORD, CT components described in this Owner's Report during the period Z-E-o I to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

IN*CTOR'S SIGNATURE DATE 7.

have Inspected the

Florida Power NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 4/12/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WCRIK PFIFO)PMFI) RY (NAMFT RFPAIR C)R(,ANI7ATIC)N P n NIIMRFR. WlR NIIMRFP. FTC

3.

FLORIDA POWER CORPORATION WR 368807 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM SDECAY HEAT CLOSED CYCLE COOLING (DC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAiRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED VALVE AGCO N/A N/A DHV-69 N/A REPLACEMENT X

F 4

+

1-1 t

t t

F F

+

+

I

+/-

+

+/-

1 P

T T

L 4

+

+

I P

fT F

4

-t 1

t TT I

4 1-1-

i i

F r -

F 4

+

+

+/-

t F-I-4

+

I-

+

+

F-I-L 4

+

h 1-1-

rr F

-t F

t-

-i-r r

F 4

+

F t

t F

F-I__

I

-1 F

P i

-i F

F I

1-1-

rr F

I I-I-

1 I

F 4

F F

F F

F 4

F F

F F

r-r-F 4

F t

F F

F I _______________

.1 __________________

I. __________

I ________________

I RET: Life of Plant RESP: Nuclear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 368807 Page 2 of 2

DESCRIPTION OF WORK REPLACED VALVE BY BOLTING

7.
8. TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A ps N/A 0F DPrAAPV'q (INIrl I Ire NAANt I AMTI

)PD, z nATA QPPCMT Mi INAPM? IP APPI I'ARI P\\

DHV-69 IS A VACUUM RELIEF VALVE, HYDORSTATIC OR PRESSURE TESTING WAS NOT PERFORMED.

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNERS DESIGNE

  • E-M--TL DATE Patrick M, Peter TITLE ISI Specialist 4/12/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed THE HARTFORD STEAM BOILER I & I COMPANY of by HARTFORD, CT have inspected the components described in this Owner's Report during the period 3 -

o oI to 4--Z3-071

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARD. STATE, PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE DT

/

DATE 900 431 Page 2 Rev. 11/94

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 1/10/02 "1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WCt)R PrRF:iOCIP Ff RY INAMfMl:%

RFP.RIR

(`Rt*MIT1T]

P rl M11JARF1R \\V

JII, RF FT1
3.

FLORIDA POWER CORPORATION WR 371012 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. EL 34428-6708 IDENTIFICATION OF SYSTEM

4.

NUCLEAR SERVICES CLOSED CYCLE COOLING.SW)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

N416-1 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO PIPE N/A N/A N/A SW0028-29 N/A REPLACEMENT X

_____________I I_ ________________I_____I

___J_______I_______

___I.

I 4

+

I 1

4 1

4 4

4-4 4 4 t

1 1

t I

1t

+

t 1

1 t

1 1t

4

+

4 4

t 4

4 t

RET: Life of Rant RESP: Nuclear Engineering 900 431 1 _________________________ {

.1 ________________ 1 ___________________________ 1 _______ 1 _______________________________

Rev. 1110,4

NIS-2 CONTINUATION WR# 371012 Page 2

of 2

DESCRIPTION OF WORK CUT AND RE-WELDED 2.5" PIPE IN SUPPORT OF RCP-1 B SW COOLER WORK.

7.
8. TESTS CONDUCTED PRESSURE TEST TEMP.

NOMINAL OPERATING PRESSURE 135 psi 82 OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNOEYATURE TITLE DATE Patrick M. Peter~soL_-

Project Analyst 1/10/02 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by HSB CT of HARTFORD, CT have inspected the components described in this Owner's Report during the period i-o-o/

to 1_-o_0ý__

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARDi, STATE, PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE DATE 900 431 Page 2 Rev. 11194

Florida Power 40 CORPORATION NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE 1

Florida Power Corporation 10/05/2000 P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PERFORMED BY (NAME)

REPAIR ORGANIZATION, P.O. NUMBER, WR NUMBER, ETC.

3.

FLORIDA POWER CORPORATION WR 365080 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT (RC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A

6.

Identification of Components Repaired or Replaced And Replacement Components NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CH COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO VALVE DRESSER BL-8899 N/A RCV-8 N/A REPLACEMENT X

_I I

_ I I

I i

4 t

I I

4 4

+

I I

I t-r-1 4

+

.4 t

I 1

4 4-

.4 4-4 1-1--

4 4

1-1 1-1 r-r-4 4

+/-

1 1

r-r-4 4

+

I

(-4 4

4 4-

+

4 4

I-I-4 i

1-t I

I I1

______ I RET: Life of Plant RESP: Nuclear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 365080 Page 2

of 2

DESCRIPTION OF WORK REPLACED RCV-8 BY BOLTING

7.
8.

TESTS CONDUCTED PRESSURE TES NOMINAL OPERATING PRESSURE 2155 Psi 532 TF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE TITLE DATE Patrick M. Peterso--------

ISI Specialist 10/05/2000 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period q -0 to l0-zG-,0oO

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE DATE 900 431 Page 2 Rev. 11/94 COMMISSIONS (NATIONAL BOARD, STATEi PROVINCE OR ENDORSEMENTS;5,,

RFlorida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/1/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnPIk PrRizlMprn RY waruirt T1:

PAIR C

  • PrN.ITi7ATICMI P rl 1III WArFP

-R MI IIMARF

-r'

3.

FL ORIDA POWER CORPORATION WR 366665 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT MCI APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ASME SECTION 111 1971 WINTER 1971 1 NA APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I NA

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED

'YES NO CRDM DIAMOND 570 354 G13/1114 1977 REPLACEMENT X

POWER CRDM DIAMOND 218 356 L8/1116 1977 REPLACEMENT X

POWER CRDM DIAMOND 595 357 E13/1117 1977 REPLACEMENT X

POWER CRDM DIAMOND 159 358 B10/1118 1977 REPLACEMENT X

POWER CRDM DIAMOND 230 359 011/1119 1977 REPLACEMENT X

POWER CRDM DIAMOND 228 360 F14/1120 1977 REPLACEMENT X

POWER CRDM DIAMOND 231 361 G5/1121 1977 REPLACEMENT X

POWER CRDM DIAMOND 167 365 B8/1125 1977 REPLACEMENT X

POWER J

I __________

 ______

[ _________

I ___

I RET: Life of Plant RESP: Nudear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 366665 Page 2

of 2

DESCRIPTION OF WORK REPLACE CRDM'S BY BOLTING.

7.
8. TESTS CONDUCTED PRESSURE TEST TEMP.

NOMINAL OPERATING PRESSURE 2130 psi 532 0F REMARKS IINCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGN TITLE DATE JOHN A. WALKER,44j/I, NUCLEAR PROJECT 11/1/01 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORID,CT have inspected the components described in this Owner's Report during the period

___to

/?-4,--

/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

AW4 

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS) 900 431 Page 2 INSPE&TOR'S SIGNATURE DATE Rev. 11/94

rid a P ow e r A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM DATE OWNER Florida Power Corporation 10/29/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042 2

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WCRP( PrRF*P*AFrM RVt It&AMFM RFPAIR (IAN)117ATION P n Mi IMARFR WP NI IARFR P:-T*

3.

FLORIDA POWER CORPORATION WR 366884 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. Fl 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT (R,)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 NA /

NA APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

NA 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO VALVE DRESSER BU03148 NA RCV-9 NA REPLACEMENT X

RET: ULfe of Rant RESP: Nuclear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 366884 Page 2

of 2

DESCRIPTION OF WORK REPLACE VALVE BY BOLTING.

7.
8. TESTS CONDUCTED PRESSURE TEST TEMP.

NOMINAL OPERATING PRESSURE 2130 psi 532 OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER

%'/

NUCLEAR PROJECT 10/29/01 aeýýIlt4SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period

/0-2z o0' to

/0-__0-0/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE DATE 900 431 Page 2 Rev. 11194

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE

1.

Florida Power Corporation 6/13/01 P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PFPIF'RMF') RY (NAMF)

PFPAIR OPGAN7ATION. P.n. NIIMRFP. WI NI IMRFI. FTC.

3.

FLORIDA POWER CORPORATION WR 366978 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

DECAY HEAT REMOVAL SYSTEM (DH)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA. CODE CASES 5a. ASME III 1989 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N-416-1

6.

Identification of Components Repaired or Replaced And Replacement Components NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO VALVE WALWORTH N/A N/A DHV-3 N/A REPLACEMENT X

RET: Life of Plant RESP: Nuclear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 366978 Page 2 of 2

DESCRIPTION OF WORK INSTALLED CANOPY SEAL ENCLOSURE TO VALVE DHV-3 BODY AND BONNET BY WELDING per MAR #P00080301.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

NOMINAL OPERATING PRESSURE 2150 psi 532

'F DP?,AAIR l1KN'l I inrP MAlMI FACTI IPFIM. frATA OrPPlDT MI IMRP I.P APPI IrARI F\\

9.

[,SME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XA of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGP M=-,

TITLE DATE Patrick M. Peterso*,

J*

Project Analyst 6/13/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed THE HARTFORD STEAM BOILER I & I COMPANY of by HARTFORD, CT have inspected the components described in this Owner's Report during the period 4__8-o/

to

_ --i_-oi

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1qf-9 COMMISSIONS (NATIONAL BOARD, STATE. PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE D -/3-<T DATE 900 431 Page 2 7.

Rev. 11/94

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 10/29/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 W

kPI(

PrprnpMur Ry ii

,rpMiF,,

P IR RnOrC.&Iu7TITlN P

m NIIMRPP WP NitIMRFR rTt'

3.

FLORIDA POWER CORPORATION WR 367235 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM 4-REACTOR COOLANT (IC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5

ANSI B31.1 1967 NA NA APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

NA 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO VALVE DRESSER BL-08900 NA RCV-8 NA REPLACEMENT X

RET: Life of Plant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 367235 Page 2

of 2

DESCRIPTION OF WORK REPLACE VALVE BY BOLTING.

7.

8 TESTS CONDUCTED PRESSURE TEST TEMP.

NOMINAL OPERATING PRESSURE 2130 psi 532 OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATR~

TITLE DATE JOHN A. WALKER

/~,

~NUCLEAR PROJECT 10/29/01 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of

_____________HARTFORD, CT nave inspected tne components described in this Owner's Report during the period i5-zsr-a1 to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.z'*J, F '¢.C,/+/-'4c4 2 INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900431 Page 2 Rev. 11/94

e Forida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 10/29/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WARIk PFpPF*C:PFArf R' INy MP PrFPAIR 1R(M*MI7ATThIn P n

.IIM.

P W A -,

lIIMPnp,

T,

3.

FLORIDA POWER CORPORATION WR 367328 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR C00LANT (RC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5.ANSI B31.1 1967I NA I NA APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

NA 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO VALVE DRESSER BL08901 NA RCV-1 0 NA REPLACEMENT X

VALVE VELAN 5156 NA RCV-1 1 NA REPLACEMENT X

RET: Ufe of Rant RESP: Nuclear Engineering 900 431

  • 11/94

NIS-2 CONTINUATION WR# 367328 Page 2

of 2

DESCRIPTION OF WORK REPLACED VALVES BY BOLTING.

7.

8 TESTS CONDUCTED PRESSURE TEST TEMP.

NOMINAL OPERATING PRESSURE 2130 psi 532 OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2__-___

0_

to 6-5*.

J

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECTfl'S SIGNATURE

//-&-

DATE 900 431 Page 2 cs--- ji-s-Di Rev. 11/94

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation

1.

P.O. Box 14042 11/150 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnRIk PFPIR*MFI; A RV I IJANAFI ePrPIR ArANI:

7ATInNC P '

N1 IMR:R WP KI11 IMRPR FýrT(

3.

FLORIDA POWER CORPORATION WR 368141 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER.

FL 34428-6708 IDENTIFICATION OF SYSTEM 4._

DECAY HEAT REMOVAL (DH)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

NSI 31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION X1 UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 720135 N/A DHH-19 N/A REPLACEMENT X

I I

+

I F

T I

I

+

1 1

F I

L

-I.

I 1 _____________

L L

.1-1

+

I-I-

+

I.

  • t*

I 1T rr I

I.

+

I 1 RET: Ufe of Plant RESP: Nuclear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 368141 Page 2

of 2

DESCRIPTION OF WORK REPLACED 2.5x5 POWER PIPING SNUBBER 720139 WITH LIKE-FOR-LIKE SNUBBER 720135, WHICH WAS

7. REBUILT PER WR 368278.

8 TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNER'S DESIGNEE S URE TITLE DATE Patrick M. Peters Project Analyst 11/15/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period z-8 -0 I to

/____-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector. nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIOrIS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE DATE 900431 Page 2 Rev. 11194

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/09/2001 P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PERFORMED BY (NAMEI REPAIR ORGANIZATION. P.O. NUMBER. WR NUMBER. ETC.

3.

FLORIDA POWER CORPORATION WR 368146 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT (RC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A

6.

Identification of Components Repaired or Replaced And Replacement Components NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED ASME COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 730014 N/A RCH-76 N/A REPLACEMENT X

11 1

liii

NIS-2 CONTINUATION WR# 368146 Page 2 of 2

7.

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 730147 WITH LIKE-FOR-LIKE SNUBBER 730014, WHICH WAS REBUILT UNDER WR 368404.

8 TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER. IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/09/2001 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period Z /

to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTSI IN4PECTOR'S SIGNATURE DATE

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/8/01 1

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnRI( PFRFIrMIfl RY INtMrl RrpPAIp nfrA.J1NI7ATIn*N P n MI

  • 1RFR WR NI IMRPP F'Tr
3.

FLORIDA POWER CORPORATION WR 368147 ADDRESS 1 5760 W-POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSIB31.1 1967 N/A /

N/A APPLICABLE EDITION OF SECTION X1 UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 730139 N/A RCH-74 N/A REPLACEMENT X

RET: Life of Rant RESP: Nudear Engineering 900 431 I _______________

I I __________I ________________

I ____ I __________________

Rev. 11194

NIS-2 CONTINUATION WR# 368147 Page 2

of 2

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 730113A WITH LIKE-FOR-LIKE SNUBBER 750139, WHICH WAS REBUILT UNDER WR 368296.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNER'S DESIGNE5IG NATURE TITLE DATE Patrick M. Peters PROJECT ANALYST 11/8/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2., 8-0 to j/,/Lo7"

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (N0ATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE

/i-/#AT /

DATE 900 431 Page2 Rev. 11194 7.

l Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/09/2001 P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnRK ppFRh::*C~rl Iy IIdAMF*

R7pAII flp*AN7AITIAMl P rl IJI INARF1 WR 111 I? MR:R -"'

3.

FLORIDA POWER CORPORATION WR 368148 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT (RC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSIB31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED SNUBBER POWER PIPING 760200 N/A RCH-73 N/A REPLACEMENT

+

t I

1 1

11 4

4

  • 1-1 1-1 1 I

+

i X -I-i

+

1 1

1 11

4 t

1 1

1 11 4

+/-

I 1

1 R*-- I ifA nf PRant RESP-Nuwrn-Pnninrinn qW 4.11 41-1

NIS-2 CONTINUATION WR# 368148 IPage 2

of 2

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 730131 WITH LIKE-FOR-LIKE SNUBBER 760200, WHICH WAS REBUILT UNDER WR 368397.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE John A. Walker NUCLEAR PROJECT 11/09/2001

,6 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD. CT have inspected the components described in this Owner's Report during the period

z. -&0 to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

i'NSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 7.

e Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/8/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 Wr)I( PFRFnRM~rn RV IFJAMFIPFAI ARrAM7ATAnr P 0 lNiI INARPR WR MJI IMRPU

Tr
3.

FLORIDA POWER CORPORATION WR 368149 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. Fl 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT (RC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANsI B21.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 760197 N/A RCH-65 N/A REPLACEMENT X

NIS-2 CONTINUATION WR# 368149 Page 2

of 2

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 750122 WITH LIKE-FOR-LIKE SNUBBER 760197, WHICH WAS REBUILT UNDER WR 369629.

8 TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE(

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/8/01 SPECIALI ST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT components described in this Owner's Report during the period 8-01 to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 7.

have inspected the

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION Xl NIS-2.FRM OWNER DATE Florida Power Corporation 11/15/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 Wnpic pF:R P uFn" M Fi: R i m u* M j

FPAIR

)(R1&ltII7ATIIOM P

II U11 F1R WIR II I IMR:F:R

-TI

3.

FLORIDA POWER CORPORATION WR 368154 ADDRESS 15760 W. POWER LINE STREET.

CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAKE UP & PURIFICATION (MU)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 750125 N/A MUH-45 N/A REPLACEMENT X

1.1.1 11

-I 4

t 1-1 1

T1 I

{

+

t I

4 t

T I

I I

r

______________________.1 1

RET: Life of Rant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368154 Page 2

of 2

DESCRIPTION OF WORK REPLACED 1.5X5 POWER PIPING SNUBBER 730228 WITH LIKE FOR-LIKE SNUBBER 750125, WHICH WAS RE BUILT PER WR 368303.

8 TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE S, R

TITLE DATE Patrick M. PetersQ_

Project Analyst 11/15/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2-*,-0/

to

//__-/(

__C__/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the-Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

[WiECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900 431 Page 2 7.

Rev. 11/94

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 1 1/8/01

1.

P.O. Box 14042 St. Petersburg, FL 337334042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnPK P:Prr0MFP:r) RY INAMFI r:PAIR t1A1g(lAM17TAT[lN P NIMRPP W-NI IMR::

PTCP

3.

FLORIDA POWER CORPORATION WR 368155 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. EL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAKE UP & PURIFICATION (MU)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A /

N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 750112 N/A MUH-43 N/A REPLACEMENT X

F F

1 1

1 1

11

_______________________ F I

I I

I I

1 1 I

F I

I I

I I

I i

i 1-I i

F F

t 1-11 11 II i

+/-

1 1 i I

I I

F

+

I I

11 I

I I

+

I I

t RET: Life of Plant RESP: Nudear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368155 Page 2

of 2

7.

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 760193 WITH LIKE-FOR-LIKE SNUBBER 750112, WHICH WAS REBUILT UNDER WR 368394.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A

'F REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2.8-oi to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900 431 Page 2 Rev. 11194

0 Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation

1.

P.O. Box 14042 1

5/01 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 wnOp:

PFrFfP4r AFfn RY 4

IN &AFI j

FPAIR p,,,nCrt I7IA TIfNIM p l

P l wIRp Am

/NIIMRR F'ýTC

3.

FLORIDA POWER CORPORATION WR 368156 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAKEUP & PURIFICATION (MU)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSIB31.1 1967 N/A L N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 760194 N/A MUH-39 N/A REPLACEMENT X

L

.4 4

  • 4

+

4 1 I 4

4 I

4 4

1-1

.4 4

  • 4 11
  • 41

_______________________ L 1

4

.4 4-4 1 4 t

I.

  • 4

+

4 I

I 11

I.

4 4

.4 4-4

4 I 4

4 I

t-t i-1 I.

.4 4

.4 4

t 11

I.

4 4

1 4

t 11 I.

4 4

.4 4-4 4 I 4

4

.4 4

t 1-i-

.4 4

1 4

1 4

1

[ ________________

I

.

REr: Life of Plant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368156 Page 2

of 2

7.

DESCRIPTION OF WORK REPLACED 1.5X5 POWER PIPING SNUBBER 730150 WITH LIKE FOR-LIKE SNUBBER 760194, WHICH WAS RE 3UILT PER WR 368396.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIG TITLE DATE Patrick M. PetersorV___

Project Analyst 11/15/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 9-OJ to

//-__--__/_

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900 431 Paae 2 Rev. 11194

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/8/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Une Street Page 1

of 2

Crystal River, FL 34428-6708 lAIrIRl PFRPrKnR Fn LY INM-I AFPVIRG flR(IANI 7ATIC)N P n mi irAMRPR wA Nil INARp

.Tr'

3.

FLORIDA POWER CORPORATION WR 368157 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAKE UP & PURIFICATION (MU)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. IANSI B3R1 -1 1967 N/A I

N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 740003 N/A MUH-35 N/A REPLACEMENT X

__I__

I.

I F

F

4.

4 1

I t-

TT 4

4 1

1 1t TT

________I.

I I

4F Ft I

I I

t-t TT I

4 1

i-f tT

.1.

I_______

I I

i 4 i-t tI

NIS-2 CONTINUATION WR# 368157 Page 2

of 2

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 730231WITH LIKE-FOR-LIKE SNUBBER 740003, WHICH WAS REBUILT UNDER WR 363025.

8. TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER

~y

~NUCLEAR PROJECT 11/8/01 0ý4 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period z--Zo I to

//-Z7-cý /

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or

implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

C

/M v' IONAL 0ARD, S V

O R

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECI*OR'S SIGNATURE

//- 27-0 1 DATE 7.

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/09/2001

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PERFORMED BY (NAME)

REPAIR ORGANIZATION. P.O. NUMBER. WR NUMBER. ETC.

3.

FLORIDA POWER CORPORATION WR 368177 ADDRESS 1 5760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

DECAY HEAT REMOVAL (DH)

APPUCABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION X1 UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 750104 N/A DHH-39 N/A REPLACEMENT X

I 1

1

__________.1.

I--1 __________________

1-1-I I

I 1

1t 11 I.

+

i-i-

_______________________ I _________________________ I. _____________________________ I ________________ +/- __________________________ I _______ +/-

I I

+

+/-

I I

11

NIS-2 CONTINUATION WR# 368177 Page 2

of 2

7.

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 730129 WITH LIKE-FOR-LIKE SNUBBER 750104, WHICH WAS REBUILT UNDER WR 368405.

8. TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A

°F REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER. IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER

~ /

,4 '/NUCLEAR PROJECT 11/09/2001 67f~~M

'I-4Y SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period Z-8-a 1 to 113-o01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE

9A

2Ac>4J COMMISSIONS (PlATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation

1.

P.O. Box 14042 11/8/01 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WIr)k* Prp~nRhtA!rn Fty njf*4i

,RPaIR nfRC.I

,iI7ATIINh P n MI iMRP1 W-M11MI II

PP

-r.

3.

FLORIDA POWER CORPORATI WR 368178 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

CORE FLOOD (CF)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 720083 N/A CFH-1 8 N/A REPLACEMENT X

RET: Life of Rant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368178 IPage 2

of 2

DESCRIPTION OF WORK REPLACED 2.5"X5" POWER PIPING SNUBBER 730230 WITH LIKE-FOR-LIKE SNUBBER 720083, WHICH WAS REBUILT UNDER WR 368273.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER

~~7NUCLEAR PROJECT 11/8/01 4:2 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2-9-0 (

to

.I-41-O I

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/Al COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

II*PECTOR'S SIGNATURE DAE /

DATE 900 431 Page 2 7.

Rev. 11194

Horida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/8/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnPI( Prv:

RnhArF RV INlMPI jM PPPAIP frIPr.AML7tTICINI P rl kIIIMRFI:R WR NI IMRIPR iTr'

3.

FLORIDA POWER CORPORATION WR 368179 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. Fl 34428-6708 IDENTIFICATION OF SYSTEM

4.

CORE FLOOD (CF)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSIB31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 730018 N/A CFH-17 N/A REPLACEMENT X

RET: Life of Rant RESP: Nuclear Eigineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368179 Page 2

of 2

DESCRIPTION OF WORK REPLACED 4"X5" POWER PIPING SNUBBER 720105 WITH LIKE-FOR-LIKE SNUBBER 730018, WHICH WAS

7. REBUILT UNDER WR 356198.
8. TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A

°F REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2--

P to I1-,*

-0

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

--



INSrECTOR'S SIGNATURE COMMISSIONS [NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900 431 Page 2 Rev. 11194

OfRorida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation

1.

P.O. Box 14042 11/8/01 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Une Street Page 1

of 2

Crystal River, FL 34428-6708 WnRk PFPRF:RKMF RV F'

(NA&:FI rFPAIPR Cr4PrAMl7ATI1I)J P (4 NIP A1 FP1;1 W"R MI tIRF=rP r'I'r,

3.

FLORIDA POWER CORPORATION WR 368415 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAKE UP & PURIFICATION (MU)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31,1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA. CODE CASES 5b.

1989 NO ADDENDA

/

N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 720132 N/A MUH-41 N/A REPLACEMENT X

I RET: Life of Rant RESP: Nuclear Engineering 900 431 4

I.

4

.4 I.

f

-I-I-Rev. 11194

NIS-2 CONTINUATION WR# 368415 Page 2

of 2

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 720125 WITH LIKE-FOR-LIKE SNUBBER 720132, WHICH WAS REBUILT UNDER WR 368395.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATR TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/8/01 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2-e-cl to fl-*--1

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPEO'TIOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE Rev. 11/94 7.

900 431 Page 2

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 10/30/01 P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PERFORMED BY (NAME)

REPAIR ORGANIZATION. P.O. NUMBER, WR NUMBER, ETC.

3.

FLORIDA POWER CORPORATION WR 368180 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

CORE FLOOD (CF)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 740047 N/A CFH-14 N/A REPLACEMENT X

RET: Ufe of Plant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368180 Page 2

of 2

DESCRIPTION OF WORK REPLACED 2.5"X5" POWER PIPING SNUBBER 740046 WITH LIKE-FOR-LIKE SNUBBER 740047, WHICH WAS REBUILT UNDER WR 368275.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER. IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SrAjTUeAREls TITLE DATE Patrick M. Pee Project Analyst 10/30/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period le-o -0,-o to

//*-,/[

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective meas ures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

h0c COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTSI DATE 900431 Page 2 Rev. 11/94 7.

INSPECTOR'S SIGNATURE

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/8/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WAnAk PFRFA*AFri RV IMek rl RFP11IP APtAIMI7&TIANk P n III 1IRCr W11 MI IWRPM

Tr,
3.

FLORIDA POWER CORPORATION WR 368427 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAKE UP & PURIFICATION (MUI APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION X1 UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 730140 N/A MUH-42 N/A REPLACEMENT X

RET: Life of Rant RESP: Nudear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 368427 Page 2

of 2

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 730222 WITH LIKE-FOR-LIKE SNUBBER 730140, WHICH WAS REBUILT UNDER WR 368403.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNERS DESIGNEE SIGN

/

TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/8/01 U'

SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period

/2.14-o0 to l-i4-+oi

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE DAiT-o /

DATE 900 431 Page 2 Rev. 11/94 7.

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 12/11/01 1.

P.O. Box 14042 St. Petersburg, FL 33733-4042 PLANT Florida Power Corporation

2.

Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnPK PFrpFPmrtl Ry tIaMF*

[PPI-I f

AM7AtlI P

TI 1

)

p C NIIfARF:R WR MIL1NARP F1 tC

3.

FLORIDA POWER CORPORATION WR 370040 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. EL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT (RC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ASMF SECTION III 196F5 THU AUMER 1967 /

NA APPLICABLE EDITION OP SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I N-416-1 N-638

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO REACTOR BABCOCK &

620-0007-51-52 N-117 RCRE-1 1971 REPLACEMENT X

VESSEL WILCOX RET: Life of Plant RESP: Nuclear Engineering 900 431 Rev-11/94

NIS-2 CONTINUATION WR# 370040 Page 2

of 2

9.

-I DESCRIPTION OF WORK MODIFY CRDM NOZZLE # 32 BY WELDING PER MAR 01-09-02-01.

7.
8.

TESTS CONDUCTED PRESSURE TEST TEMP.

NOMINAL OPERATING PRESSURE 2125 psi 532 OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

RELIEF REQUESTS 01-0002-RR AND 01-0003-RR FOR THIS MODIFICATION WERE APPROVED BY THE NRC.

(NRC to FPC LETTER 3N1201-04)

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIC.UAT--..F-TITLE DATE Patrick M. Peters&q -

-7 Project Analyst 12/11/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by HSB CT of HARTFORD, CT have inspected the components described in this Owner's Report during the period 10-3-0 1 to S-Lo-C'L

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE l-1o-oZ.

DATE 900 431 Page 2 Rev. 111g4

FRorida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 1 1/8/0 1

1. *P.O.

Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WrfPI( PPPrAF PKM:l RV INAM FIF Rj:FPAIIR CI1R(AIMI7ATT]i7 P

rl IMIF, III AIIP 11 III/IR1::PIF -Tr

3.

FLORIDA POWER CORPORATION WR 371706 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR COOLANT (RC)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967I N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 750132 N/A RCH-81 N/A REPLACEMENT X

4

-I-

+

4 4

4 1 ______________

4-4 4

4-4 4 4

+/-

4 1

7 7

1T 4

4-4 4

4 4

4 4-

+

+

4 t

4 4-4 4

4 4

4 4-t t-t 4

+

4 t

r-t 77 4

4-4 4

7t

4-4 4

4-4 4 4

+

t 4



7 7T RET: Life of Plant RESP: Nuclear Engineering 900 431 4

4-4

+

4 4

t-4 Rev. 11194

NIS-2 CONTINUATION WR# 371706 Page 2

of 2

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 750100 WITH LIKE-FOR-LIKE SNUBBER 750132, WHICH WAS REBUILT UNDER WR 368304.

8. TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER Z4 NUCLEAR PROJECT 11/8/01 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period

/o-1-21/

to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSýPtECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE Rev. 11/94 7.

900431 Page2

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 1 0/31/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 Wn KRI(

PrRFPPPA:r RV INAMF 1 pPA&IR lPCr1ANI,7ATICth P n MI I IMRFR W t NI IMItlPR

  • T
3.

FLORIDA POWER CORPORATION WR 357800 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM 4,

1MAKEUP & PURIFICATION (MU)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5

ANSI B31.1 1967 NA NA APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

NA 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SUPPORT NA NA NA MUH-587 NA REPAIRED X

SUPPORT NA NA NA MUH-590 NA REPAIRED SUPPORT NA NA NA MUH-609 NA REPAIRED SUPPORT NA NA NA MUH-763 NA REPAIRED RET: Ufe of Plant RESP: Nudear Engineering 900 431 Rev-11194

NIS-2 CONTINUATION WR# 357800 Page 2

of 2

DESCRIPTION OF WORK REPAIR SUPPORTS BY WELDING.

7.
8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A NA Ps' NA OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 10/31/01 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period i8-7-0o to 11 Oi

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS INATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECT61R'S SIGNATURE DATE 900 431 Page 2 Rev. 11/94

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/16/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnRk piFR1F:

RV ImAmFI

[7*eIn

-A1 AAII7ATIMlI P 11 MIJ)

INAPFRl W-NI IMRPR

-rt

3.

FLORIDA POWER CORPORATION WR 363265 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER.

EL 34428-6708 IDENTIFICATION OF SYSTEM

4.

FUEL HANDLING (FH)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ASME SECTION 111 19 65 1967 1 N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO FUEL N/A N/A N/A FHX-1A N/A REPLACEMENT X

TRANSFER TUBE 4-4

-

t tt

4-4 F

F tt tt 4-4 F

F

-t F

t-t-4-

4 T

t t-r-4-

4

-

f 4-4 F

F 1-F F-F-4-

4 T

t TT 4

4-4 F

F 4--F t-F-4-

4 t-r-

+/-

4 F

t tF 4-4 F

F

-t--F F-F-4-

4 F

F

-F-F I-F-4-

4 r

r A.

Rev 11194 RET: Ufe of Rant RESF: Nudear Egineenng 900 431 RET: Life of Plant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 363265 Page 2

of 2

DESCRIPTION OF WORK REPLACED MISSING BOLTS.

7.
8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A 0F REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNER'S DESIGNEE 3eN-AT-1RE"*I'*

TITLE DATE Patrick M. Peter sn.

Project Analyst 11/16/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period

?- g-9/

to

/i__*_

I

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE z /9'c/1)

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900 431 Page 2 Rev. 11194

Florida Power C RORP0RATION NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE 1

Florida Power Corporation 12/13/2000 P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PERFORMED BY (NAME)

REPAIR ORGANIZATION, P.O. NUMBER, WR NUMBER, ETC.

3.

FLORIDA POWER CORPORATION WR 367039 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

EMERGENCY FEEDWATER (EF)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 1-NO ADDENDA I N/A

6.

Identification of Components Repaired or Replaced And Replacement Components NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED cAW COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SUPPORT POWER PIPING N/A N/A EFH-70 N/A REPLACEMENT X

1 4

1 1

-i II I

4 4

+

1-14 I__

I I

I +

i f

4

+

-I-1 1

7-r-4 4

1-1-

1t t-r-4 4

+

1-i-t t-t-4 F

+

1 t-t-4 4

F

+

I I

t-t-

-I 4

1 I

1 1

1 1

RET: Life of Plant RESP: Nuclear Engineering 900 431 I ______________

I Rev. 11/94

NIS-2 CONTINUATION WR# 367039 Page 2

of 2

DESCRIPTION OF WORK REPLACED ONE CLAMP BOLT.

7.
8.

TESTS CONDUCTED PRESSURE TESTTEMP.

N/A N/A Psi N/A TF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class,91i CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIC TITLE DATE Patrick M. Peterson T.

ISI Specialist 12/13/2000 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period

/O- 0-.- ew to

/2-1i - 0

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900 431 Page 2 Rev. 11194

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 10/25/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PERFORMED BY (NAME)

REPAIR ORGANIZATION. P.O. NUMBER. WR NUMBER, ETC.

3.

FLORIDA POWER CORPORATION WR 367605 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAIN STEAM (MS)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSIB31.1 1967 NA / NA APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ NA

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO VALVE NA NA NA MSV-26 NA REPLACEMENT X

RET: Ufe of Plant RESP: Nuclear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 367605 Page 2

of 2

DESCRIPTION OF WORK REPLACE VALVE INTERNALS.

7.
8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A NA psi NA OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER. IF APPLICABLEI

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 10/25/01

-1 6SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2--e--1 to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Rep ort in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' s Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE DATE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS) 900431 Page2 Rev. 11/94

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/9/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 wnfkw PFpFrPmrI:

RPm I1MFP RF=P*IR (

.'1p l,(17ATICMN P l NI IMRF=R WPAR M IMRFR F'l T'

3.

FLORIDA POWER CORPORATION WR 368144 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

NUCLEAR SERVICES CLOSED CYCLE COOLING (SW)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSI B31.1 1967 N/A /

N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 760199 N/A SWR-423 N/A REPLACEMENT X

.1-4 4-

.4.

-I-

+/-

1-

-F

-F t

4-

+

+

1-1-

4-

-I-

+

1-1-

4-4 1-4-

T T

rT 4-4 4-

+

+1-RET: Life of Plant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368144 Page 2

of 2

DESCRIPTION OF WORK REPLACED 1.5"X5" POWER PIPING SNUBBER 750120 WITH LIKE-FOR-LIKE SNUBBER 760199, WHICH WAS REBUILT UNDER WR 368402.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A JSI N/A

°F REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE,~,

TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/09/2001 SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2 -.1-.-O to 11/1.-/321

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS) 11SPECTOR'S SIGNATURE DATE 7.

c Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/15/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WNRIK PFRRFCI MFR RV hilAMF rFPPIR AeI71IATTrlN PrI N 1111MPrR W-I NI IMRFP F-r.

3.

FLORIDA POWER CORPORATION WR 368159 ADDRESS 15760 W.

POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM 4_

MAIN STEAM (MS)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5,ANSI B31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 730039 N/A MSH-581 N/A REPLACEMENT X

______ I I

  • t-



t 11

L

.4 4-



t 1 RET: Life of Plant RESP: Nuclear Engineering 900 431 L

.4 4-Rev. 11194

NIS-2 CONTINUATION WR# 368159 Page 2

of 2

DESCRIPTION OF WORK REPLACED 2X5 POWER PIPING SNUBBER 760175 WITH LIKE FOR-LIKE SNUBBER 730039, WHICH WAS RE BUILT PER WR 368261.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE TITLE DATE Patrick M. Peters)n, Project Analyst 11/15/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2-.L

-' I to P

_-46-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE COMMISSIONS NATIONAL BOORD, STATE, PROVINCE OR ENDORSEMENTS)

-a /

DAW 900 431 Page 2 Rev. 11/94

F Rorida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/09/2001 P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 Wnpk" P:rPrMnpur RY IMAMFi P:PPIR 1R(I)MI7ATIOInm P n MIImIPPR R

AMIIMRF:p

'r
3.

FLORIDA POWER CORPORATION WR 368164 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAIN STEAM (MS)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 740036 N/A MSH-167 N/A REPLACEMENT X

4 4

-I-1 1

__________ I

ii

NIS-2 CONTINUATION WR# 368164 Page 2

of 2

DESCRIPTION OF WORK REPLACED 4"X5" POWER PIPING SNUBBER 730117 WITH LIKE-FOR-LIKE SNUBBER 740036, WHICH WAS

7. REBUILT UNDER WR 368280.

8 TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A pJsi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNERS DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/09/2001 SSPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period z____ __a_-0to 111-/4-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/8/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WCRIK PFRPrnMPfl1 RY l.AAMPI PrPA1P riPrl'NJI7ATI*TI1t P n NI IM1PF IMJP MII IARFR

TC
3.

FLORIDA POWER CORPORATION WR 368165 ADDRESS 115760 W. POWER LINE STREET. CRYSTAL RIVER. EL 34428-6708 IDENTIFICATION OF SYSTEM

4.

MAIN STEAM (MS)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B331.1 1967I N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 720075 N/A MSH-147 N/A REPLACEMENT X

RET: Life of Rant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368165 Page 2

of 2

DESCRIPTION OF WORK REPLACED 5"X5" POWER PIPING SNUBBER 720073 WITH LIKE-FOR-LIKE SNUBBER 720075, WHICH WAS

7. REBUILT UNDER WR 368394.
8. TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A Psi N/A OF REMARKS INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNTR

ý TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/8/01 C~.'..'U.~'(SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY Of HARTFORD, CT have inspected the components described in this Owner's Report during the period Z. 8-01 to 2.01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS INATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTSI DATE Rev. 11/94 INSPECTOR'S SIGNATURE 900 431 Page 2

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/8/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnRI( PrP:rRM F

tl fY INIAMZM RFPAIP rflltAN7AITITIlM P

PI NI IMRF:R WP NI IM4RPR P-Tr

3.

FLORIDA POWER CORPORATION WR 368171 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM 4_

r-FEFDWATER (FW)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSIB31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 740092 N/A FWH-140 N/A REPLACEMENT X

_[I I __

_I I

I__

_I_

_ I_

NIS-2 CONTINUATION WR# 368171 Page 2

of 2

DESCRIPTION OF WORK REPLACED 2.5"X5" POWER PIPING SNUBBER 740080 WITH LIKE-FOR-LIKE SNUBBER 740092, WHICH WAS REBUILT UNDER WR 368268.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A 0F REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNERS DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/8/01 C/w SPECIALIST CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD. CT have inspected the components described in this Owner's Report during the period 2 _e-0 /

to

,//_/.____:;_/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 7.

e Rorida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/15/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WoRi PrRF:nphllrl RY iNrMIFI P:PAIR nRrAKIJ7ATI(hiP P )N IMi R:RFR WJR K1 IMRFR FTr.

3.

FLORIDA POWER CORPORATION WR 368172 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

FEEDWATER (FW)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 760036 N/A FWH-1 28 N/A REPLACEMENT X

RET: Ufe of Rant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368172 Page 2

of 2

DESCRIPTION OF WORK REPLACED 5X5 POWER PIPING SNUBBER 760068 WITH LIKE-FOR-LIKE SNUBBER 760036, WHICH WAS RE BUILT PER WR 368292.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS fINCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNE

    • E TITLE DATE Patrick M. Peero Project Analyst 11/1 5/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2-g-o) to

/__--

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

COMMISSIONS ýNATVONZL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSPECTOR'S SIGNATURE DATE 900 431 Page 2 7.

Rev. 11194

Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation

1.

P.O. Box 14042 11/15/01 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 wnpik PrpFORpmrf Ry mamI RF:PAIR flRJCrAI7ATIMN P () 1,l IMPFR W"P MI PI4RF:P PTt

3.

FLORIDA POWER CORPORATION WR 368173 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER. EL 34428-6708 IDENTIFICATION OF SYSTEM

4.

EMERGENCY FEEDWATER (EE)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSIBR21 ý1 1967 N/A I

N/ZA APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 730217 N/A EFH-27 N/A REPLACEMENT X

+

I.-

I

  • I I

I 1

1 4

I 4

4 4

1 I.

4

.4 4

.4 I

I I

I 1

1 11 4

  • 4

+

4

.4 I I

1 1

1 1

11 I

I 4

4 4

.4 RET: Life of Plant RESP: Nudear Engineering 900 431

______________________ I _________________________ I _____________________________ I ________________.1 ___________________________ +/- _______ +/- _______________________________

Rev. 11194

NIS-2 CONTINUATION WR# 368173 Page 2

of 2

DESCRIPTION OF WORK REPLACED 2.5X5 POWER PIPING SNUBBER 730116 WITH LIKE FOR-LIKE SNUBBER 730217, WHICH WAS RE BUILT PER WR 368269.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A Psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section X1 of the ASME Code.

OWNER OR OWNER'S DESIGNEES TITLE DATE Patrick M. PetersProject Analyst11/15/01 CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2..-1/

to

_____________/_

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSfECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900 431 Page 2 7.

Rev. 11/94

"Florida Power CORPORATION NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 5/28/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PF#FC)IMFr RY (NAMF)

IFPAIR CIIrANI7ATICrN P n NI IMRFI? WP NI IMRFR FTC.

3.

FLORIDA POWER CORPORATION WR 368175 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM SDECAY HEAT REMOVAL SYSTEM (DH)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a. ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO COMPONENT POWER PIPING 750134 N/A DHR-24U N/A REPLACEMENT X

SUPPORT RET: Life of Plant RESP: Nuclear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 368175 Page 2

of 2

DESCRIPTION OF WORK REMOVED SNUBBER S/N 750125 FROM LOCATION DHR-24U AND REPLACED WITH LIKE-FOR-LIKE SNUBBER S/N 750134, WHICH WAS REBUILT UNDER WORK REQUEST 359852.

8. TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A

'F D NAAf)Vq fNiril 1 II11 *AANII I*A TI IIom-'z nATA DPrDIT Nil INAP1iD 19 ADDI I ApI I=

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNA D-1 TITLE DATE Patrick M. Peterso rKý

ýJ.

Sr, Project Analyst 5/28/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed THE HARTFORD STEAM BOILER I & I COMPANY of by HARTFORD, CT have inspected the components described in this Owner's Report during the period 2-6-cl to

'-6 -of

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

IN§PECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE. PROVINCE OR ENDORSEMENTS)

DATE 900 431 Page 2 7.

Rev. 11/94

Florida SPower NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 5/28/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WnP(K PFPF()RMFI) RY (NAMFP 1FPAIR CRCANI7ATIC)N P (

NI IMRFR WR NI IMRFP FTC.

3.

FLORIDA POWER CORPORATION WR 368176 ADDRESS 15760 W. POWER LINE STREET, CRYSTAL RIVER, FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

DECAY HEAT REMOVAL SYSTEM (DH)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA. CODE CASES 5a.

ANSI B31.1 1967 N/A / N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/ N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO COMPONENT POWER PIPING 730128 N/A DHR-24L N/A REPLACEMENT X

SUPPORT RET: Life of Plont RESP: Nuclear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 368176 Page 2 of 2

DESCRIPTION OF WORK REMOVED SNUBBER S/N 740003 FROM LOCATION DHR-24L AND REPLACED WITH LIKE-FOR-LIKE SNUBBER S/N

7. 730128, WHICH WAS REBUILT UNDER WORK REQUEST 359800,
8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A

-F Dr1\\AADkWR (lNCrIl I IFP UAANII PA(-TI IDPPI'q nATA DrPP f)T Nil INAPPID Ip APPI IrARI rý

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XA of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIG TURE TITLE DATE Patrick M. Peterson Sr. Project Analyst 5/28/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed THE HARTFORD STEAM BOILER I & I COMPANY of by HARTFORD, CT have inspected the components described in this Owner's Report during the period 2-3-0/

to 6.//-0 /

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD. STATE. PROVINCE OR ENDORSEMENTS)

DATE 900 431 Page 2 Rev. 11 /94

e Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION Xl NIS-2.FRM OWNER DATE Florida Power Corporation 11/15/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 W41R4( PrFRF(

AAF:* RV tNAMMF RFI:PAIR r1R1Ir.A 1I'7ATI(3Mi P 1 NI I NIRFP 1 WR N I

IRI:ARF FT r,

3.

FLORIDA POWER CORPORATION WR 368181 ADDRESS 15760 W.

POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

CORE FLOOD (CE)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5

ANSI B31.1 1967 N/A I NIA APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 720138 N/A CFH-13 N/A REPLACEMENT X

.1.

1 1

____ 1 i-I-4 4

4

+

4 1 +

t 1

1 4

+

4 4

1 11 4

+

I I

I-I-

+/-

4-4 4

+

4 4 RET: Ufe of Rant RESP: Nuclear Engineering 900 431

+

t t

4 1

T 1

Rev. 11/94

NIS-2 CONTINUATION WR# 368181 Page 2

of 2

7.

DESCRIPTION OF WORK REPLACED 2.5X5 POWER PIPING SNUBBER 720137 WITH LIKE FOR-LIKE SNUBBER 720138, WHICH WAS RE BUILT PER WR 368271.

8. TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLEJ

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNER'S DESIGNEE TITLE DATE Patrick M. Peterson Project Analyst 11/15/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period Z-.

I to l//-/6-0/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

IISPECTOR'S SIGNATURE DATE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS) 900 431 Page 2 Rev. 11194

fRorida Power A Progress Energy Company NI S-2 OWNER'S REPORT OF REPAI R OR REPLACEMENT AS REQUI RED BY THE PROVI SI ONS OF ASME CODE SECTI ON XI NIS-ZFI OVNER DATE Florida Power Corporation 8/6/01 P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WORK PERFORMED BY (NAME)

REPAIR ORGANIZATION, P.O. NUMBER. WR NUMBER ETC,

3.

FLORi DA POWER CORPORATI ON WR 368182 ADDRESS 15760 W. POWER LI NE STREET, CRYSTAL RI VER, FL 34428-6708 I DENTI R CATl ON OF SYSTEM

4.

REACTOR BUI LDI NG SPRAY (BS)

APPU CABLE CONSTRUCTION CODE EDITION ADDENDA CODE CASES 5a. ANSI B31.1 1967 N/A I N/A APPUCABLE EDITION OF SECTION YJ UTI UZED FOR REPAIRS OR REPLACEMENTS ADDENDA CODE CASES 5 b.

1989 NO ADDENDA I N/A

6.

Identification of Components Repaired or Replaced And Replacement Components ASM E NAME OF NAME OF MANUFACTURER'S NATI ONAL OTHER YEAR REPAI RED, REPLACED CODE COMPONENT MANUFACTURER SERI AL NUMBER BD. NO.

I DENTI Fl CATI ON BUILT OR REPLACEMENT STAMPED YES NO SUPPORT/

POWER PI PI NG 750073 N/A BSR-35 N/A REPLACEMENT X

SNUBBER 4

4 4

4

  • I 4-4--

+

4*

4-4 4-4 1.-i--

4

.4-4-

4

+

+

RET: Ufe of Rant RESP: Nudear Engineering 900 431 Rev. 11/94

NIS-2 CONTINUATION WR# 368182 Page 2 of 2

DESCRIPTION OF WORK REPLACED SNUBBER 720113 VV]TH LIKE FOR LIKE SNUBBER 750073.

7.
8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A TF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section Xl of the ASME Code.

OWNER OR OWNER'S DESIGNEE S

-F -

TITLE DATE Patrick M. Peterso TITE Project Analyst 8/6/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2-8-0 to of1

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

INSPECTOR'S SIGNATURE 8-7-c1 DATE

,--z-N (1ATINAL B,4)

COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS) 900431 Page2 Rev. 11/94

FRorida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 1 1/8/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 W()P* PrCPMPflP :l* RV INAMFl:

RPPPAIP Cr1Pn. AMI7ATII' P 1) MI I11RFP:11 WP NI IFAP:R

-r,

3.

FLORIDA POWER CORPORATION WR 368183 ADDRESS 15760 W. POWER LINE STREET-CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM

4.

REACTOR BUILDING SPRAY (BS)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

NSIB311 1967 N/A /

N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA I

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 730114 N/A BSH-1 5 N/A REPLACEMENT X

RET: Ufe of Rant RESP: Nuclear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368183 Page 2

of 2

DESCRIPTION OF WORK REPLACED 2"X5" POWER PIPING SNUBBER 720079 WITH LIKE-FOR-LIKE SNUBBER 730114, WHICH WAS

7. REBUILT UNDER WR 369625.
8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE SIGNATURE TITLE DATE JOHN A. WALKER NUCLEAR PROJECT 11/8/01 1ýý*

SPECIALIST CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2 6-0i to

-i4-41-/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

______/______/2,7__,

C,(

INSPECTOR'S SIGNATURE COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

DATE 900 431 Paqe 2 Rev. 11/94

S Florida Power A Progress Energy Company NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT AS REQUIRED BY THE PROVISIONS OF ASME CODE SECTION XI NIS-2.FRM OWNER DATE Florida Power Corporation 11/15/01

1.

P.O. Box 14042 St. Petersburg, FL 33733-4042

2.

PLANT Florida Power Corporation Crystal River Unit 3 15760 W. Power Line Street Page 1

of 2

Crystal River, FL 34428-6708 WOPI( PFRFORIPFrI RY INAU AFI:

R=PAIR ArPrAII7ATIOM*I P )

NI IMFRP R W1 MI IMRPFP

PTCr,
3.

FLORIDA POWER CORPORATION WR 368200 ADDRESS 15760 W. POWER LINE STREET. CRYSTAL RIVER. FL 34428-6708 IDENTIFICATION OF SYSTEM 4,

FEEDWATER (FW)

APPLICABLE CONSTRUCTION CODE EDITION ADDENDA, CODE CASES 5a.

ANSI B31.1 1967 N/A I N/A APPLICABLE EDITION OF SECTION XI UTILIZED FOR REPAIRS OR REPLACEMENTS ADDENDA, CODE CASES 5b.

1989 NO ADDENDA

/

N/A 6,

Identification of Components Repaired or Replaced And Replacement Components ASME NAME OF NAME OF MANUFACTURER'S NATIONAL OTHER YEAR REPAIRED, REPLACED CODE COMPONENT MANUFACTURER SERIAL NUMBER BD. NO.

IDENTIFICATION BUILT OR REPLACEMENT STAMPED YES NO SNUBBER POWER PIPING 760071 N/A FWH-147A N/A REPLACEMENT X

RET: Life of Rant RESP: Nudear Engineering 900 431 Rev. 11194

NIS-2 CONTINUATION WR# 368200 Page 2

of 2

7.

DESCRIPTION OF WORK REPLACED 4X5 POWER PIPING SNUBBER 890002 WITH LIKE FOR-LIKE SNUBBER 760071, WHICH WAS RE BUILT PER WR 369616.

8.

TESTS CONDUCTED PRESSURE TEST TEMP.

N/A N/A psi N/A OF REMARKS (INCLUDE MANUFACTURER'S DATA REPORT NUMBER, IF APPLICABLE)

9.

ASME Code Class 2 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Replacement Conforms to Section XI of the ASME Code.

OWNER OR OWNER'S DESIGNEE

ý"-,

TITLE DATE Patrick M. Peters*

Project Analyst 11/1 5/01 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of FLORIDA employed by THE HARTFORD STEAM BOILER I & I COMPANY of HARTFORD, CT have inspected the components described in this Owner's Report during the period 2.-6-ci to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

OI 4N

(

VA1 /

T COMMISSIONS (NATIONAL BOARD, STATE, PROVINCE OR ENDORSEMENTS)

INSP*CTOR'S SIGNATURE DATE 900 431 Page 2 Rev. 11194