05000461/FIN-2017002-07
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Root Cause Evaluation Failed to Identify Corrective Action to Preclude Repetition |
| Description | Green . The inspectors identified a finding of very low safety significance and an associated non -cited violation of 10 CFR Part 50, Appendix B, Criterion II, Quality Assurance Program, for the failure to implement a quality assurance program procedure. Specifically, the licensee failed to document a root cause and develop a corrective action to preclude repetition for the 1A bus transformer failure in accordance with quality assurance procedure PI AA 125 1001, Root Cause Analysis Manual. The licensee entered this issue into their CAP as AR 01594407. The corrective actions in response to this issue were to revise the root cause report with a root cause of insulation degradation of the phase windings over time and develop a corrective action to prevent recurrence by using Doble testing to ensure indication of transformer insulation degradation was discovered prior to failure. The performance deficiency was determined to be more than minor because if left uncorrected the performance deficiency had the potential to lead to a more significant safety concern. Specifically, the root cause and corrective actions to prevent recurrence were not identified until the licensee was prompted by the inspectors. As a result, additional transformer failures could have occurred. The finding was screened against the Initiating Events cornerstone and determined to be of very low safety significance because the finding did not involve the complete or partial loss of a support system that contributes to the likelihood of or cause an initiating event nor did it affect mitigation equipment. The inspectors determined this finding affected the cross -cutting area of human performance, in the aspect of resources, where leaders ensure that personnel, equipment, procedures and other resources are available and adequate to support nuclear safety. Specifically, the licensees station procedure did not provide guidance on when a corrective action to preclude repetition is required, regardless of whether a risk assessment was performed. [H.1] |
| Site: | Clinton |
|---|---|
| Report | IR 05000461/2017002 Section 4OA2 |
| Date counted | Jun 30, 2017 (2017Q2) |
| Type: | NCV: Green |
| cornerstone | Initiating Events |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | W Schaup E Sanchez-Santiago M Doyle S Bell G Edwards V Meghani L Torres S Mischke K Stoedter |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion II |
| CCA | H.1, Resources |
| INPO aspect | LA.1 |
| ' | |