05000456/FIN-2011004-09
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Design of Auxiliary Feedwater System Included Voids in Safety-Related Alternate Suction Flow Paths |
Description | The inspectors identified a finding of very low safety significance (Green) and an associated NCV of 10 CFR Part 50, Appendix B, Criterion III, Design Control, when licensee personnel failed to properly analyze the configuration of the SX connections to the AF pumps. Specifically, a section of the piping was intentionally maintained empty (voided), but was not previously analyzed. This condition existed since initial plant construction. The issue was entered into the licensees corrective action program as IR 1173517. Additionally, the licensee filled the voided sections of pipe, restoring compliance with the licensed design basis. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems Cornerstone attribute of Design Control and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Specifically, the unverified configuration might have rendered each of the AF pumps inoperable. The inspectors determined the finding could be evaluated using the SDP in accordance with IMC 0609, Significance Determination Process, Attachment 0609.04, Phase - 1 Initial Screening and Characterization of Findings, Table 4a, for the Mitigating Systems Cornerstone. Specifically, the inspectors answered Yes to Question 1 of the Mitigating Systems Cornerstone column of the Phase 1 worksheet because the inspectors concluded that this finding was confirmed not to result in a loss of operability. This conclusion was reached after reviewing tests performed by the licensee. The tests demonstrated there was reasonable assurance that the AF system would perform its safety function in the installed configuration. Based on this Phase 1 screening, the inspectors concluded that the issue was of very low safety significance (Green). Due to the age of this issue, the inspectors did not identify a cross-cutting aspect associated with this finding because it was not indicative of current licensee performance. |
Site: | Braidwood ![]() |
---|---|
Report | IR 05000456/2011004 Section 4OA2 |
Date counted | Sep 30, 2011 (2011Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | A Garmoe B Palagi D Reeser E Duncan G O'Dwyer J Benjamin M Perry R Ng |
INPO aspect | |
' | |
Finding - Braidwood - IR 05000456/2011004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2011Q3
Self-Identified List (Braidwood)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||