Finding | |
|---|---|
| Title | Failure to Adequately Implement a Design Change Associated with the RWSTs |
| Description | The team identified a finding of very-low safety significance (Green), and an associated NCV of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the licensees failure to translate applicable design basis into Technical Specifications (TSs) Surveillance Requirement 3.5.4.2 implementing procedures. Specifically, these procedures did not verify the RWST vent line was free of ice blockage at the locations, and during all applicable MODEs of reactor operation assumed by the ECCS and containment spray (CS) pump NPSH calculation. The licensee captured this issue into their CAP to reconcile the affected procedures and calculation. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems cornerstone attribute of design control, and affected the cornerstone objective of ensuring the availability, reliability, and capability of mitigating systems to respond to initiating events to prevent undesirable consequences. Additionally, it was associated with the Barrier Integrity cornerstone attribute of design control, and affected the cornerstone objective of providing reasonable assurance that physical design barriers protect the public from radionuclide releases caused by accidents or events. The finding screened as very-low safety significance (Green) because it did not result in the loss of operability or functionality, and it did not represent an actual open pathway in the physical integrity of reactor containment. Specifically, the licensee performed a historical review of the last 3 years of operation, and did not find any instances in which the vent path temperature fell below 35 degrees Fahrenheit. The inspectors did not identify a cross-cutting aspect associated with this finding because it was confirmed not to be reflective of current performance due to the age of the performance deficiency. (Section 1R21.5.b(2)) |
| Site: | Byron |
|---|---|
| Report | IR 05000454/2015008 Section 1R21 |
| Date counted | Sep 30, 2015 (2015Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | A Della Grecab Palagi C Lipa D Betancourt J Leivo M Jones N Feliz-Adorno |
| Violation of: | Technical Specification - Procedures 10 CFR 50 Appendix B Criterion III, Design Control Technical Specification |
| INPO aspect | |
| ' | |