05000454/FIN-2015008-10
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Maintain the Instrument Loops Used to Verify Compliance with the Containment Average Air Temperature TS Limit |
| Description | The team identified a finding of very-low safety significance, and an associated NCV of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the failure to have procedures to maintain the accuracy within necessary limits of the instrument loops used to verify compliance with the containment average air temperature TS limit of 120 degrees Fahrenheit. Specifically, in 2007, the licensee cancelled the periodic preventive maintenance (PM) intended to maintain the necessary instrument loops accuracy. The licensee entered this issue into their CAP and reasonably established that the 120 degrees Fahrenheit limit was not exceeded by reviewing applicable historical records from 2002 to time of this inspection. The performance deficiency was determined to be more than minor because it was associated with the configuration control attribute of the Barrier Integrity Cornerstone, and adversely affected the cornerstone objective to ensure that physical design barriers protect the public from radionuclide releases caused by accidents or events. The finding screened as very-low safety significance (Green) because it did not represent an actual open pathway in the physical integrity of reactor containment or involved an actual reduction in hydrogen igniter function. Specifically, the containment integrity remained intact and the finding did not impact the hydrogen igniter function. The team determined that this finding had a cross-cutting aspect in the area of problem identification and resolution because the licensee did not identify issues completely and accurately in accordance with the CAP. Specifically, on January 15, 2015, the licensee captured the lack of periodic PM activities for the containment air temperature instrument loops in the CAP. However, the licensee failed to completely and accurately identify the issue in that it was not treated as a CAQ. As a consequence, no corrective actions were implemented. [P.1] |
| Site: | Byron |
|---|---|
| Report | IR 05000454/2015008 Section 4OA2 |
| Date counted | Sep 30, 2015 (2015Q3) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | A Della Grecab Palagi C Lipa D Betancourt J Leivo M Jones N Feliz-Adorno |
| Violation of: | 10 CFR 50 Appendix B Criterion V Technical Specification Technical Specification - Procedures |
| CCA | P.1, Identification |
| INPO aspect | PI.1 |
| ' | |