05000445/FIN-2015008-03
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Inadequate Procedure for Surveillance on Safety-Related Service Water Systems |
| Description | The team identified a non-cited violation of Technical Specification (TS) 5.4.1, Procedures, for an inadequate procedure for performing surveillances on the station service water (SSW) systems in units 1 and 2. Specifically, Procedures OPT-207 A and B, Service Water System, were modified in September 2010 so that failure of any SSW vacuum breaker to OPEN was considered a degraded condition and not an inoperable condition of the associated SSW System train. However, per DBD-ME-233, Station Service Water, Revision 33, Active Valves, vacuum breakers are required by ASME [Code Section] III on the inlet and outlet piping to the diesel generator jacket water coolers to mitigate the effects of water hammer due to water column separation and subsequent rejoining following a pump trip. This issue does not represent an immediate safety concern because the licensee confirmed that all of the vacuum breakers in service had passed their most recent surveillance test. The licensee entered this issue into the corrective action program for resolution as Condition Report CR-2015-010800. The finding is more than minor because it is associated with the procedure quality attribute of the Mitigating Systems cornerstone and affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Specifically, the licensee did not ensure the guidance incorporated into quality related procedures was accurate and consistent with the design basis analysis for the systems and this conflict resulted in inadequate operability determinations associated with the SSW System. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, Exhibit 2, Mitigating Systems Screening Questions, dated June 19, 2012, the team determined that the finding is of very low safety significance (Green) because (1) the finding was not a deficiency affecting the design or qualification of a mitigating system; (2) the finding did not represent a loss of system and/or function; (3) the finding did not represent an actual loss of function of a single train for greater than its technical specification allowed outage time; and (4) the finding does not represent an actual loss of function of one or more non-technical specification trains of equipment designated as high safety-significant in accordance with the licensees maintenance rule program for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. This finding has a human performance cross cutting aspect associated with design margins because the licensee failed to operate and maintain the SSW system equipment within design margins. Rather than ensure that margins are carefully guarded and changed only through a systematic and rigorous process, the licensee failed to re-evaluate SSW system operability with failed vacuum breaker valves even when additional test information indicated previous assumptions were incorrect [H.6]. |
| Site: | Comanche Peak |
|---|---|
| Report | IR 05000445/2015008 Section 4OA2 |
| Date counted | Sep 30, 2015 (2015Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | C Alldredge E Ruesch H Freeman J Drake J Josey |
| Violation of: | Technical Specification - Procedures Technical Specification |
| CCA | H.6, Design Margins |
| INPO aspect | WP.2 |
| ' | |
Finding - Comanche Peak - IR 05000445/2015008 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Comanche Peak) @ 2015Q3
Self-Identified List (Comanche Peak)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||