Finding | |
|---|---|
| Title | Failure to Evaluate Operability When Breeching Hazard Barriers |
| Description | The inspectors identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, associated with the licensees failure to perform adequate operability assessments when disabling hazard barriers during maintenance activities. Specifically, during maintenance activities in the main steam/main feed penetration area, the licensee disabled the high energy line break/environmental qualification door and failed to evaluate operability of the safety-related equipment protected by this door. This issue does not represent an immediate safety concern because, at the time of identification, the doors were shut. The licensee entered the finding into corrective action program as Condition Report CR-2015-001111. The failure to properly assess and document the basis for operability when creating a degraded or nonconforming condition during a maintenance activity, breaching a high energy line break/environmental qualification barrier, was a performance deficiency. The performance deficiency was more than minor because it was associated with the equipment performance attribute of the Mitigating Systems cornerstone and affected the cornerstone objective to ensure availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the licensees opening the high energy line break/environmental qualification door resulted in a condition where structures, systems, and components necessary to mitigate the effects of a high energy line break may not have functioned as required. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, Exhibit 2, Mitigating Systems Screening Questions, dated June 19, 2012, the finding was determined to require a detailed risk evaluation because it was a deficiency affecting the design and qualification of a mitigating structure, system, or component that resulted in a loss of operability or functionality and represented a loss of system and/or function. A senior reactor analyst performed a detailed risk evaluation and determined that the finding was of very low safety significance (Green). The inspectors determined that this finding does not have a crosscutting aspect because the most significant contributor of this finding occurred in 2011 and does not reflect current licensee performance. |
| Site: | Comanche Peak |
|---|---|
| Report | IR 05000445/2015001 Section 1R13 |
| Date counted | Mar 31, 2015 (2015Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.13 |
| Inspectors (proximate) | J Josey J Kramer J O'Donnell L Carson R Kumana W Walker |
| Violation of: | 10 CFR 50 Appendix B Criterion V |
| INPO aspect | |
| ' | |
Finding - Comanche Peak - IR 05000445/2015001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Comanche Peak) @ 2015Q1
Self-Identified List (Comanche Peak)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||