05000440/FIN-2008004-08
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Licensee-Identified Violation |
| Description | Technical Specification (TS) 3.5.3, Emergency Core Cooling Systems (ECCS) and Reactor Core Isolation Cooling (RCIC) System, Condition A.1, required that when the RCIC system is inoperable, it must be verified within one hour, by administrative means,that HPCS system is operable. Condition B.1 of TS 3.5.3 requires that when the Required Action and associated Completion Times of Condition A are not met the plant must be in Mode 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. Contrary to this requirement, on December 11, 2007, the HPCS was declared inoperable for maintenance and the plant remained in Mode 1. Specifically, on January 14, 2008, the licensee discovered that the RCIC flow controller output voltage did not meet operability requirements and this condition previously existed since December 10, 2007. Not knowing that TS LCO 3.5.3was not met, licensee personnel did not make the required mode changes. Upon discovery, the licensee took immediate actions to restore RCIC operability. The finding was determined to be of very low safety significance because the system inoperable time was less than 30 days (CR 08-38443) |
| Site: | Perry |
|---|---|
| Report | IR 05000440/2008004 Section 4OA7 |
| Date counted | Sep 30, 2008 (2008Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Licensee-identified |
| Inspection Procedure: | |
| Inspectors (proximate) | M Wilk J Robbins D Reeser M Phalen R Baker M Franke T Taylor J Cameron R Murray |
| INPO aspect | |
| ' | |
Finding - Perry - IR 05000440/2008004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Perry) @ 2008Q3
Self-Identified List (Perry)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||