Title | Licensee-Identified Violation |
Description | Technical Specifications 5.4, Administrative Controls, required procedures to be established, implemented, and maintained for plant safety equipment. Contrary to this requirement, on February 20, 2008, the licensee discovered that plant personnel failed to appropriately implement procedures while conducting work on the RCIC system. The licensee documented several instances of failure to implement procedures in CRs 08-35811, 08-35725, and 08-35803. The inspectors determined that the finding was of very low safety significance because the finding did not result in a loss of safety function greater then its TS-allowed outage time |
Site: | Perry ![]() |
---|---|
Report | IR 05000440/2008002 Section 4OA7 |
Date counted | Mar 31, 2008 (2008Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Licensee-identified |
Inspection Procedure: | |
Inspectors (proximate) | M Wilk A Dahbur G Wright M Franke J Cameron |
INPO aspect | |
' | |
Finding - Perry - IR 05000440/2008002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|