Finding | |
---|---|
Title | Licensee-Identified Violation |
Description | Technical Specification 3.0.4, Limiting Condition for Operation (LCO) Applicability, required that a mode change cannot occur when an LCO is not met, unless certain conditions are fulfilled. Contrary to this requirement, on December 6, 2007, the plant changed modes when TS LCO 3.5.3 requirements were not met. Specifically, on December 12, 2007, the licensee discovered through engineering analysis and OpE review that the RCIC flow controller settings were improper. The improper flow controller settings would preclude reliable system performance in accordance with RCIC safety design criteria. The plant entered Mode 2 on December 6, 2007, and subsequently Mode 1 with RCIC inoperable. Not knowing that TS LCO 3.5.3 was not met, licensee personnel allowed the mode changes |
Site: | Perry ![]() |
---|---|
Report | IR 05000440/2008002 Section 4OA7 |
Date counted | Mar 31, 2008 (2008Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Licensee-identified |
Inspection Procedure: | |
Inspectors (proximate) | M Wilk A Dahbur G Wright M Franke J Cameron |
INPO aspect | |
' | |