05000388/FIN-2016004-03
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Refuel Floor Radiation Monitor Inoperable Due to being Improperly Calibrated |
Description | Green. A finding of very low safety significance (Green) and NCV of TS 5.4.1, Procedures was self-revealed when Susquehanna incorrectly calibrated the Unit 1 B refuel floor high exhaust duct high radiation monitor on November 15, 2014. This impacted the initiation capability of secondary containment isolation and control room emergency outside air supply system (CREOASS) and resulted in Susquehanna exceeding the allowed outage time for TSs 3.3.6.2, Secondary Containment Isolation, and 3.3.7.1, CREOASS Instrumentation. Upon identification of the issue, Susquehanna properly calibrated the radiation monitor to restore its operability. This finding is more than minor because it is associated with the Human Performance (Routine OPS/Maintenance Performance) attribute of the Barrier Integrity cornerstone and affected the cornerstone objective of providing reasonable assurance that physical design barriers (Secondary Containment and Control Room Ventilation) protect the public from radionuclide releases caused by accidents or events. Specifically, incorrectly calibrating the radiation monitor resulted in both systems being inoperable for almost two years. In accordance with IMC 0609.04, Initial Characterization of Findings, and Exhibit 3 of IMC 0609, Appendix A, The SDP for Findings At-Power, both dated June 19, 2012, the inspectors determined that this finding is of very low safety significance (Green) because the performance deficiency was only associated with the radiological barrier function of the Control Room and Secondary Containment. This finding had a cross-cutting aspect in the area of Human Performance, Avoid Complacency because Susquehanna did not recognize and plan for the possibility of mistakes, latent problems, or inherent risk, even while expecting successful outcomes. Specifically, Susquehanna personnel did not consider the potential undesired consequences of their actions before performing work and implement appropriate error-reduction tools (e.g. self-check, peer-check). [H.12] |
Site: | Susquehanna |
---|---|
Report | IR 05000388/2016004 Section 1R22 |
Date counted | Dec 31, 2016 (2016Q4) |
Type: | NCV: Green |
cornerstone | Barrier Integrity |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71111.22 |
Inspectors (proximate) | B Smith D Schroeder E Gray J Deboer J Furia J Greives P Ott S Anderson T Daun |
Violation of: | Technical Specification - Procedures |
CCA | H.12, Avoid Complacency |
INPO aspect | QA.4 |
' | |
Finding - Susquehanna - IR 05000388/2016004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Susquehanna) @ 2016Q4
Self-Identified List (Susquehanna)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||