DUKE POWER COMPANY W3 7

7, gl 1 '7 19

\\;\\

Ld j{,'8gs vowsu nun.oixo r

O 422 Sourn Cnuncu Srazzr, Ci AutorTz, N. C. ce24a 4

'h ww4u o. pma nca.sa.

sa

<.c,....

m S"^"""

"8' February 26, 1982

,_N 3

. v.

y n

N

, ~~)

Mr. James P. O'Reilly, Regional Administrator g

U. S. Nuclear Regulatory Commission

, a I,

Region II y

101 Marietta Street, Suite 3100 G

Atlanta, Georgia 30303 "1

C Re: Oconee Nuclear Station Docket No. 50-287

Dear Mr. O'Reilly:

Please find attached Reportable Occurrence Report R0-287/82-01. This report is submitted pursuant to Oconee Nuclear Station Technical Spec-ification 6.6.2.1.b(2) which concerns operation in a degraded mode per-mitted by a limiting condition for operation, and describes an incident which is considered to be of no significance with respect to its effect on the health and safety of the public.

Ver truly yours, I

\\

U-William O. Parker, J.

JFK/php Attachment cc: Director Records Center Office of Management & Program Analysis Institute of Nuclear Power Operations U. S. Nuclear Regulatory Commission 1820 Water Place Washington, D. C. 20555 Atlanta, Georgia 30339 Mr. W. T. Orders NRC Res'_ dent Inspector Oconee Nuclear Station [pkT AL CO"Y 8203180303 820226 PDR ADOCK 05000287 n

S PDR 0

> /{

l I

a

DUKE POWER COMPANY-OCONEE NUCLEAR STATION UNIT 3 Report Number: R0-287/82-01 Report Date: February 26, 1982 Occ.urrence Date: January 28, 1982 Facility: Oconee Unit 3, Seneca, South Carolina Identification of Occurrence: Borated Water Storage Tank Channel 'B' Level Indication inoperable Conditions Prior to Occurrence: 100% FP Description of Occurrence: On January 28, 1982, the Channel 'B' Borated Water Storage Tank _(BWST) Level Indication was declared inoperable due to erratic. readings.

Apparent Cause of Occurrence: The apparent cause of this incident was dirt and oil in the IcVel indicator booster relay, and high thermostat settings on the system heat trace causing boiling in the impulse lines.

Analysis of Occurrence:

BWST Channel 'A' level indication was operable and the BWST water level was maintaired-with the Technical Specification limits throughout this incident,' thus ensuring at. adequate water supply for emergency cooling. The safety of the plant was not degraded and the health _and safety of the public were not affected by this incident.

Corrective Action

The Channel 'B' booster relay was cleaned and the thermostat setting for the heat trace was lowered. The level indication was returned to service.