Finding | |
|---|---|
| Title | Failure to Maintain the Control Room Habitability System in the Design Configuration |
| Description | The inspectors identified a Green noncited violation of Technical Specification 5.5.19, Control Room Envelope Habitability Program, after the licensee failed to maintain the Unit 1 control room ventilation train in the design configuration. The inspectors identified that Unit 1 control room ventilation system was in a degraded/non-conforming condition on August 31, 2011. The inspectors observed airflow bypassing the control room inlet header through disconnected ductwork. Technical Specification 5.5.19 required the licensee to maintain the habitability system in the most limited configuration used during the tracer gas in-leakage test. The disconnected ductwork was a more limiting condition than the tested configuration. The licensee took corrective action to declare the control room envelope inoperable and entered the finding into the corrective action program as Notification 50425114. The inspectors determined that the failure of the licensee to maintain the control room habitability system in the design configuration was a performance deficiency. This finding was more than minor because it was associated with the configuration control attribute of the Barrier Integrity Cornerstone and affected the cornerstone objective to provide reasonable assurance for the control room physical design to protect from radionuclide releases caused by accidents or events. The inspectors concluded that the finding was of very low safety significance (Green) because the finding only represented a degradation of the radiological barrier function provided for the control room. This finding had a crosscutting aspect in the area of human performance associated with work control in that the licensee failed to appropriately plan work activities consistent with nuclear safety |
| Site: | Diablo Canyon |
|---|---|
| Report | IR 05000275/2011004 Section 1R04 |
| Date counted | Sep 30, 2011 (2011Q3) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.04 |
| Inspectors (proximate) | G Guerra M Peck G Miller C Osterholtz E Ruesch D Reinert L Micewski |
| CCA | H.5, Work Management |
| INPO aspect | WP.1 |
| ' | |
Finding - Diablo Canyon - IR 05000275/2011004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Diablo Canyon) @ 2011Q3
Self-Identified List (Diablo Canyon)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||