05000263/FIN-2014008-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Both Redundant Safe Shutdown Trains of Nitrogen Bottles were Found Located In the Same Fire Area |
| Description | The inspectors identified a finding of very-low-safety significance and associated NCV of 10 CFR Part 50, Appendix R,Section III.G.1 for the licensees failure to ensure one of the redundant SSD trains located in the same fire area was free of fire damage. Specifically, both trains of redundant nitrogen bottles used to open and maintain open Safety Relief Valves (SRVs) to depressurize and cooldown the reactor were found located in the same fire area. The licensee entered the issue into their Corrective Action Program and established hourly fire tours in the affected fire areas. The performance deficiency was determined to be more than minor because the finding was associated with the Mitigating Systems cornerstone attribute of Protection Against External Factors (Fire) and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to fire events prevent undesirable consequences (i.e., core damage). Specifically, the licensee failed to ensure that one train of nitrogen to supply credited SRVs to achieve and maintain shutdown conditions would be free of fire damage because both trains of nitrogen bottles were located in the same fire area. The finding represented a low degradation and therefore the inspectors determined that the finding screened as having very-low-safety-significance (Green) in Task 1.3.1 of IMC 0609, Appendix F. The finding was not associated with a crosscutting aspect because the finding was not representative of current performance. |
| Site: | Monticello |
|---|---|
| Report | IR 05000263/2014008 Section 1R05 |
| Date counted | Mar 31, 2014 (2014Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.05 |
| Inspectors (proximate) | A Dahbur D Oliver R Daley R Winter |
| Violation of: | 10 CFR 50 Appendix R |
| INPO aspect | |
| ' | |
Finding - Monticello - IR 05000263/2014008 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Monticello) @ 2014Q1
Self-Identified List (Monticello)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||