Finding | |
---|---|
Title | Inadequate Verification of Design Analyses for Recirculation Pump NPSH |
Description | The team identified a finding of very low safety significance (Green) involving a non-cited violation of 10 CFR.Part 50, Appendix B, Criterion lll, Design Control, because Entergy had not verified the adequacy of the existing design analyses for internal recirculation pump net-positive-suction-head (NPSH) margin and vapor containment strainer allowable head loss determinations. Specifically, the recirculation pump flow system hydraulic modeling assumption relative to zero leakage through an idle recirculation pump check valve was not verified or consistent with the existing test method which could allow significant backflow with the established pump and check valve test acceptance criteria. Entergy entered the issue into their corrective action program to evaluate and resolve the design deficiency, and performed an operability evaluation to ensure there was adequate NPSH margin. The performance deficiency was determined to be more than minor because it was associated with the design control attribute of the Mitigating Systems Cornerstone and adversely atfected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The team evaluated the finding in accordance with IMC 0609, Appendix A, The Significance Determination Process (SDP) for Findings at Power, Exhibit 2 - Mitigating Systems Screening Questions. The finding was determined to be of very low safety significance because it was a design deficiency confirmed not to result in a loss of operability. This finding was not assigned a cross-cutting aspect because it was a historical design issue not indicative of current performance. Specifically, the performance deficiency had occurred outside of the nominal three year period for evaluating present performance as defined in IMC 0612. |
Site: | Indian Point |
---|---|
Report | IR 05000247/2012007 Section 1R21 |
Date counted | Dec 31, 2012 (2012Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | M Singletary M Yeminy A Della Grecad Kern D Orr F Arner J Schoppy L Doerflein |
INPO aspect | |
' | |
Finding - Indian Point - IR 05000247/2012007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2012Q4
Self-Identified List (Indian Point)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||