NRC-19-0010, Inservice Inspection Summary Report for Activities Performed at DTE Electric Company'S (DTE) Fermi 2 Nuclear Power Plant During the 19th Refueling Outage in Fall 2018

From kanterella
(Redirected from ML19023A531)
Jump to navigation Jump to search
Inservice Inspection Summary Report for Activities Performed at DTE Electric Company'S (DTE) Fermi 2 Nuclear Power Plant During the 19th Refueling Outage in Fall 2018
ML19023A531
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 01/23/2019
From: Polson K
DTE Energy
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC-19-0010
Download: ML19023A531 (5)


Text

Keith J. Poison Senior Vice President and CNO DTE Energy Company 6400 N. Dixie Highway, Newport, MI 48166 Tel: 734.586.4849 Fax: 734.586.1431 Email: keith.polsondteener2y.com DYE Energy-January 23, 2019 10 CFR 50.55a NRC-19-0010 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington D C 20555-0001

Reference:

Fermi 2 NRC Docket No. 50-341 NRC License No. NPF-43

Subject:

Inservice Inspection Summary Report Enclosed is the Summary Report of the Inservice Inspection (ISI) activities performed at DTE Electric Company's (DTE) Fermi 2 Nuclear Power Plant during the 1 9 th Refueling Outage in Fall 2018. This report represents a partial summary of the ISI activities for the third Ten-Year Inspection Interval that began on May 2, 2009 and is scheduled for completion on May 1, 2019.

This report is being submitted in accordance with Code Case N532-4 on the Form OAR-1, Owner's Activity Report.

Should you have any questions or require additional information, please contact Mr. Scott A.

Maglio of my staff at (734) 586-5076.

Sincerely, Keith J. Polson Senior Vice President and CNO

Enclosure:

Form OAR-1 Owner's Activity Report

USNRC NRC-19-0010 Page 2 cc: NRC Project Manager NRC Resident Office Reactor Projects Chief, Branch 5, Region III Regional Administrator, Region III M. Wilson - Authorized Nuclear Inservice Inspector (ANII)

Michigan Public Service Commission Regulated Energy Division (asselind1@michigan.gov)

M. Moore - Chief Inspector Michigan Department of Labor & Economic Growth Bureau of Construction Codes and Fire Safety - Boiler Division

Enclosure to NRC-19-0010 Fermi 2 NRC Docket No. 50-341 Operating License No. NPF-43 Form OAR-1 Owner's Activity Report

Fermi 2 Nuclear Power Plant Form OAR-1 Owner's Activity Report Report Number RF-19 OAR-1 Plant Fermi NPP 6400 North Dixie Hwy, Newport, MI 48166 (Name and Address of Plant)

Unit No. 2 Commercial Service Date 1/23/1988 Refueling Outage No. 19 (if applicable)

Current Inspection Interval 3rd (1st, 2nd, 3rd, 4th, other)

Current Inspection Period 3rd (1st, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans 2001 Edition with 2003 Addenda Date and Revision of inspection plans 11/12/2015, Revision 10 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans Code Case used: N-460, N-532-4, N-586-1, N-613-1, N-639, N-685, N-702, N-716-1 (if applicable)

CERTIFICATE OF CONFORMANCE I certify that (a)the statements made inthis report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI; and (c)the repair/replacement activities and evaluations supporting the completion of RF-19 conform to the requirements of Section XI. (Refueling Outage Number)

Signed Marc A. Brooks / Date _ _ _ _ _ _ _ _ _

Owners or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by The Hartford Steam Boiler Inspection and Insurance Company of One State St., Hartford CT have inspected the items described inthis Owner's ActivityReport, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described inthis report. Furthermore, neither the Inspector nor his employer shall be liable inany manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Mark Wilson / Commissions NB9486 I N M1610 nspector's Signature National Board, State, Province, and Endorsements Date O/ / z 1/11/2019 ScheduleWorks V. 8.1 Page 1 - 1

RF19 Owners Activity Report Attachment TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Number Item Description Evaluation Description None Required TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Description Date Repair/Replacement Class Description Of Work Completed Plan Number ASME Class 3 External 18-047 1-4 Corrosion / Leak at RHR 3 Complex Wall Penetration Replaced leaking pipe 10/25/2018 CA D 18-298624 Number 152 RF19 OAR-1 Attachment Page 1