Finding | |
---|---|
Title | Failure to Maintain Safety Injection Tank Boron Concentration within Technical Specification Limits |
Description | A Green, self-revealing, non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI Corrective Action was identified because the licensee failed to identify and evaluate an adverse trend related to boron concentration in Safety Injection Tank (SIT) SI-6A and to take corrective actions to prevent boron concentration from going below the minimum concentration required by Technical Specifications. The licensees immediate corrective actions included documenting this condition in their corrective action program in Condition Report (CR) 2015-10181, declared SI-6A inoperable, and raised SI-6A boron concentration. The finding is more than minor because it adversely affected the equipment performance attribute of the mitigating systems cornerstone, in that this finding resulted in the SIT becoming inoperable when boron concentration fell below TS limits for approximately 8.5 days prior to August 20, 2015. Analysis conducted by a Senior Reactor Analyst determined the finding to be of very low safety significance (Green), primarily because the SIT function is needed only for mitigation of a postulated large-break loss of coolant accident, and the initiating-event frequency for such accidents is 2.5 x 10-6/year. The finding has a cross-cutting aspect in the area of Problem Identification and Resolution and the Evaluation aspect, because the licensee did not thoroughly evaluate the issue and ensure that resolutions addressed causes and extent of conditions commensurate with their safety significance. |
Site: | Fort Calhoun ![]() |
---|---|
Report | IR 05000285/2015003 Section 1R15 |
Date counted | Sep 30, 2015 (2015Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71111.15 |
Inspectors (proximate) | B Baca B Hagar C Peabody D You F Ramirez G Guerra G Miller J Drake M Brooks P Elkmann S Makor S Schneider B Cummings |
Violation of: | 10 CFR 50 Appendix B Criterion XVI Technical Specification |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |
Finding - Fort Calhoun - IR 05000285/2015003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|