Rev. 21 to Updated Final Safety Analysis Report, Drawing M-0010, Sheet 7, Rev. 25, PID-Service Water
ML22278A576
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A576 (1)


Text

8 1 6 5 4 3 2 8031-M-10 SH. 7 OF

11-10 TO CIM<<JN NOTES FOR SIEETS 6 AND 1 DNLY1 2491 DRAIN POT AND LO lSll.2 H-6l VENT UIE. I. DELETED.

El...315' 12".1111-228 20' Jl!D-224 _J L 20'.1111-224 TO SERVICE 2. VALVE REQUIRES CHAIN llEEL OPERATOR.

H r-.........;~~~:.......&................,.........:~:::::;~:.................. CP'l"........................ ~..,...... ilil;l;.lllilliliii:................................................................................... ~..,~r!!-.................,..........;;.;..;;;;;.;;;;...~..,........ ~~u-B1@0;:::::> =RET\\llN 3. Wl£ll USING TIE SUCTlllN AND RETUIN INTERTIES WITH A H

  • CSIL6 11.n 24" JBD-224 CDllUNG TOWER OUT OF SERVICE, NDN-ESSENTIAL 1£AT EXCHANGERS ISUCH AS RFPT Lll!E Oll. CDOlERSI MUST BE I' IO'JB0-239 TO EMERGENCY ISOLATED TO ALLOW SUFFICIEJIT COOllNG WATER FLOW TO E=--ti.....:..1*.::JBD-426::..;::;::..i U-11 SEVICE WATER ESSENTIAL 1£AT EXCHANGERS lSUCH AS FUEL POOL 1£AT 2490 UNIT 2 LOOP 1 A1 EXCHANGERS>. SERVICE WATER PIAIP OPERATION IN TIE S.S. REACTOR CONTROL OUT-OF-SERVICE UNIT IS l.1MITED TO OI£ P1A1P AT 15.400 oo:DSiiRE ENCLOSURE GPU MAXIMUM FLOW. TIE PIAIP OISDIARGE VAL VE SHOIJ..O BE FR011 EMERGENCY 8' Jl!D-216 ltz:I 12".llD-216 EL. 180'-0' THRDTTl.ED TO ATTAIN THIS CIHllTION.

SERVICE WATER L:Ju-~11c:;:;.o.....:.;:~.:.::.---c::.,...... --1~11---~--~~~-----CJ-I ~

1 A' CSH..-t CJD ~ O> 4. DEl..ETED.

UNIT 2 LOOP 20' JBD-202 FRllll SERVICE

~ 5. THIS EOUlPllENT IS BEING llllNlTOREll BY T1£ VIBRATION 12"J8D-239 ~ ---------**---~ =Sll'PLY <SH.6 G. n 24*.a>-202 MONITORING SYSTEM IVUSl. FDR TIE TYPE OF SENSORS USED, FROll ENERGEMCY~:J!:J:!::::::>-..:a~*~.flD-:::;;~z:1&:.. SERVICE WATER

  • U-11.....J SEE TIE VMS UD SLUIARY, VP D11G.. 8031-U-247-108.

UNIT 2 LOOP 'B' ISH.5 c.21

2248 1. DEl..ETED.

G G S8D

  • 8. BYPASS L11E TO BE USED lllNlllALl.Y AND Oll.Y Wl£ll I MAINTENANCE IS REQUIRED ON 85-202.

~~

~* I' SBD-210 I ~*.l!IH31..... 1:..*.::seo-=-,,.21""0'--I ~ - r ~*.llll-431 1,11--:J DRAIN 9. DEl..ETED.

VENT E---1*--......... -=-.., I 1:-.;I:,.' ::Jl!D-:::..~ 229~-11 2232A t Ip. iii :)VENT 2010A t Ip. 20108 2219 10. PITOT Tll!ES lllU BE USED FOR THESE FP'S.

~ 11. DEl..ETED.

DRW DRW t-""74',.=.llD-=-:229;:;:...-t*-:J VENT " ~* 12. SEAL FLUSH LDES REllOVED Alll CAPl'Ell REACTOR ENCLOSLllE 2218 2CP212 PER ECR 93-02621 COOLING WATER 2ACBIP212 PER ECR 94-()5539 IEAT EXCHANGERS N. 13. DEl..ETED.

~., 14. A SEALANT INJECTION LEAK REPAIR IS INSTALLED ON THIS LllE i> i> IN TIE CIRCULATING WATER PIAIP STRUCTIR.

VENT SEE ECR LG 02-D0461.

N r.i

... 15. POINT CONNECTIONS SlllWN ON DRAWING U-207-o0278 SH.2.

o>-

F NO z !20-C&nl F INIJTE IS>

12".llD-228

RECm.mNER AFTERCONDENSER

8' Jl!D-246 VENT r.i 2241 12".llD-213

=- 8'

~llt-+111-"I 2429

~* "Jl!D-213

~ VENT E:-*~~;;,:;_-t NOTE 10 HYDRO 2240 E TEST E

~TJDNl1~ 12'X 12'X 10' RED. TEE 120-C&nl

!llOTE IS>

L!J DRAIN

~ ~

~ ~ ~

I I CllECK VALVE IS

~i. l'.llll-431 IJITERNAL TO CIEL

~ INJECTlllN QWLL 2140A ORAIN

2136A 2056A NO 12"JB0-227

'-~~~~~~~~~~--11.:Jo----~~- FlE.. POOL SERVICE WATER BOOSTER PlY'S D I D 8'.llD-228 y~ NOTE 10 15 r----------~ 11--1-*.llll-4..-._.26_..... 1' 3 FIE.. POOL IEAT EXCHANGERS 2!cffi 2489

<>=l O"'<>

IC...

  • ~*......... m:c

..... 1*.seo-...,.2.10._~~~ I 3 t...

llRW,_o

.74 N ~* "'.llll-431 !,'.!z I

21388 ~1

=- =-

y =-

~ llRW llRAIN ~

~* llRAIN c 21421:... 3 VENT c

NOTE 12 r.i I

r----------~

21368

DRAIN 8'J8D-228

=-...

N

  • ~PSY *

.--1-*SBD-__ 21_0~~~~ I ~

B =- llRAIN ~

DRAIN t 21428 N DRW %' ~'.llll-431 r~z VENT!; 191 N NOTE 12 ' 3 N.

2138C ~1 I - -- - -- - - - -_, ~

DESCRIPTION 214SA 2144A Ill TABLE OF ADDITIONS &. CHANGES USE ONLY PRINTS SHOWING LATEST DATE 0 MECHANICAL

~

..... :.. P&ID
.. ~ =- SERVICE WATER r-Oi <UNIT 2) t-A ~ 1--~~~~LIMERI~~CK~GENERA~~TING~-S-T-A-TION~~~~--tA
c DRAIN ~ EXELON NUCLEAR CORP.

!1 DRAIN SCALE DRAWN !GOS CHECKED INSPECTED 0 NONE BECHTEL BECHTEL BECHTEL BECHTEL I llRAIN APPROVED _,BE_CHTEL........_ _____ APPRllVED

?! SHEET 7 OF 8 1 6 5 3 2 CATEGORY A1