Rev. 21 to Updated Final Safety Analysis Report, Drawing M-0006, Sheet 9, Rev. 14, P&ID Hydrogen Water Chemistry System Unit 1, 2, and Common
ML22278A595
Person / Time
Site: Limerick  
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A595 (1)


Text

N PURGE 2

SEE NOTE 10 YARD UNIT 1 TURBINE ENCLOSURE 2"

11/2" 3/4" 1/2" 2.

3.

4.

5.

6.

HYDROGEN DETECTOR FOR MAIN ISOLATION VALVE AREA.

  • - SUPPLIED BY VENDOR.

X 7.

8.

THIS REPRESENTS THE POSITIONER.

9.

10.

11.

12.

13.

14.

1/2" NPT SCH.80 MONEL.

ALL COMPONENT NUMBERS THAT APPEAR ON THIS P & ID, 3/4" 3/4" 3/4" ROOF

- DENOTES A PLC CONNECTION 15.

16.

17.

NUMBERS IN BRACKETS.

PROVIDED BY GE ARE DENOTED WITH THE GE I.D.

WATER CHEMISTRY SYSTEM IS P73 THE DEVICES GENERAL ELECTRIC Co. MPL No. FOR THE HYDROGEN 0020 2

0021 O STORAGE TANK FUTURE FROM N PURGE 2

0009 11/2" DCD-001 2

0011 H STORAGE TANK FUTURE FROM 11/2" 0008 0019 YARD PCV 110 SV 151 XIC 100 X

SEE NOTE 7 HYDROGEN WATER CHEMISTRY MAIN ISOLATION PANEL (BY GE) P73-P550 1/2" 1/2" HV 151 RG UNIT 1 ENCLOSURE TURBINE PI 005 0022 RV-005 11/2" DCD-001 1299 HYDROGEN COOLING TO GENERATOR 1" DCD-004 1"

3/4" DCD-001 3/4" 0024 1248 1249 XV 103 1/2" 1252 1/2" 3/4" PI 111 RV-154 1250 3/4" 1251 3/4" DCD-101 3/4" DCD-101 (A-S)

PCV-110 PI 121 RV-151 ZS 151 10-S172 3/4" DCD-001 3/4" DCD-101 N PURGE, 2

TEST & SAMPLE 1247 FROM NOTE 4 IS EXCLUDED THIS AREA 3/4" 2253 3/4" 1253 2

H SUPPLY TO UNIT 2 2" DCD-001 0029 0030 3/4" 3/4" 2299 3/4" 3/4" DCD-201 3/4" DCD-001 3/4" S

PCV 210 SV 251 XIC 200 X

SEE NOTE 7 HYDROGEN WATER CHEMISTRY MAIN ISOLATION PANEL (BY GE) P73-P550 1/2" 1/2" HV 251 RG 2248 2249 XV 202 1/2" 2252 1/2" 3/4" PI 211 RV-254 3/4" DCD-201 3/4" DCD-201 (A-S)

PCV-210 PI 221 RV-251 ZS 251 20-S172 N PURGE, 2

TEST & SAMPLE 2247 3/4" 3/4" 3/4" UNIT 2 ENCLOSURE TURBINE UNIT 1 ENCLOSURE TURBINE AFTER THE VALVE.

MONEL ASTM B-165 TRANSITION PIECE 10" IN LENGTH, SEE NOTE 4 (F556)

(F551)

(F552)

(F555)

(F554)

(R557)

(F556)

C177 (F551)

(F555)

(R557)

(F554)

C177 (F552)

C177 SPECIFICATION NE-076 AND GE DESIGN SPEC. 25A5068.

DOCUMENT NO. (25A5068,PARA.4.1.1.1)

MODULE AND TO THE INJECTION POINTS. (SEE GE HIGHEST POINT OF THE PIPE RUN TO THE INJECTION INJECTION POINT SHALL SLOPE 1/4" PER FOOT FROM THE HYDROGEN PIPING BETWEEN THE INJECTION MODULE AND 1.

2 2

NOTES:

2" DCD-002 CONTROLLERS (PLC).

XIC-06-100, 200 ARE PROGRAMABLE LOGIC GENERAL ELECTRIC EQUIPMENT IS SUPPLIED TO PECO 18.

OTHERWISE.

PIPE FOR THREADED CONNECTIONS UNLESS NOTED TYPE 316L STAINLESS STEEL; USE SCH.160 SEAMLESS PIPE IS SEAMLESS TYPE 316L SCH.80; FITTINGS ARE LINE CLASS DCD SHALL APPLY FOR H & O PIPING; 3/4" 2"

2" DCD-002 3/4" 3/4" (CONSTRUCTION)

WELDED CONNECTION FLUSH (CONSTRUCTION)

WELDED CONNECTION FLUSH 11/2" 3/4" C177 3/4" 3/4" 3/4" 2251 SHEETS 9, 10 AND 11 ARE IN SYSTEM 006A.

FEEDWATER PUMPS.

HYDROGEN DETECTOR FOR INJECTION POINTS AT REACTOR ACCORDANCE WITH SPEC. 8031-C-9.

THE UNDERGROUND PIPING IS TO BE INSTALLED IN 1/2" 3/4" 3/4" 2250 1/2" 3/4" ABOVE SURFACE ABOVE SURFACE BURIED SEE NOTE 18 2"

11/2" ABOVE SURFACE ABOVE SURFACE BURIED SEE NOTE 18 SEE NOTE 10 ABOVE SURFACE BURIED S

R E

V 8031-M-06 LIMERICK GENERATING STATION 8031-M-06 UNIT 1, 2, AND COMMON HYDROGEN WATER CHEMISTRY SYSTEM P & ID BECHTEL BECH 2/27/96 BECH BECHTEL BECHTEL BECHTEL BECHTEL CATEGORY A1 SH. 9 (SH.31 D,1)

M-15 (SH.11 E,8)

M-06 (SH.10 E,8)

M-06 (SH.10 B,8)

M-06 (SH.01 B,8)

M-28 (SH.31 D,1)

M-15 (SH.10 F,4)

M-06 TO "B" H INJECTION LINE 2

(SH.10 E,4)

M-06 TO "C" H INJECTION LINE 2

(SH.10 G,4)

M-06 TO "A" H INJECTION LINE 2

FC NE (SH.11 F,4)

M-06 TO B H INJECTION LINE 2

(SH.11 E,4)

M-06 TO C H INJECTION LINE 2

(SH.11 G,4)

M-06 TO A H INJECTION LINE 2

NE FC DELETED.

CLASS ECD.

SERVICE NOT SUPPLIED BY G.E. OR GAS SUPPLIER ARE GLOBE AND CHECK VALVES FOR OXYGEN AND HYDROGEN 0102 1/2" 1/2" 0087 1/2" 0086 1/2" 0085 1/2" 0017 1/2" XV 002 1/2" 0084 1/2" 0016 TEST 1/2" 0082 1/2" 0083 1/2" VENT 1/2" 0080 0081 FOI 002 FE 002 0038B 1/2" 1/2" 1/2" 0077B RV-004B PI 004B 002B PCV 0037B 1/2" 0037A 1/2" 0038A 1/2" 1/2" 1/2" 0077A RV-004A PI 004A 002A PCV 1/2" 1/2" 0075 RV-016 PISLL 016 C747 C177 X

SEE NOTE 7 1/2" 1/2" 1/2" 0069C RV-013C PALL 016 PIS 016 (BAY C)

TRAILER TUBE 1/2" 1/2" 0069B RV-013B (BAY B)

TRAILER TUBE 1/2" 0072A 1/2" 1/2" 0091A 1/2" 1/2" 0069A RV-013A PI 008A (BAY A)

TRAILER TUBE 1/2" 1/2" 1/2" OXYGEN GAS SUPPLY FACILITY 1/2" 1/2" 0066 1/2" 0065 1/2" 0006 1/2" XV 001 1/2" 0064 1/2" 0005 TEST 1/2" 0062 1/2" 0063 1/2" 1/2" 0060 0061 FT 001 FOI 001 FE 001 PSV 001 3/4" 1/2" 0007 0101 0018 0034B 1/2" 1/2" 1/2" 0057B RV-002B PI 002B 001B PCV 1/2" 1/2" 0056B RV-001B PI 001B 0033B 1/2" 0033A 1/2" 0034A 1/2" 1/2" 1/2" 0057A RV-002A PI 002A 001A PCV 1/2" 1/2" 0056A RV-001A PI 001A 3/4" 3/4" 1/2" 1/2" 0055 RV-010 PISLL 010 C745 X

SEE NOTE 7 PALL 010 PIS 010 10C177 1/2" 0052C 1/2" 0042C S

1/2" 0094C A

C746C A

C745 1/2" 0088C 1/2" 0003C 1/2" 1/2" 0049C RV-007C PISL 007C 1/2" 0001C (BAY C)

TRAILER TUBE C745 PIS 007C 1/2" 0052B 1/2" 0042B S

1/2" 0094B A

C746B A

C745 1/2" 0088B 1/2" 0003B 1/2" 1/2" 0049B RV-007B PISL 007B 1/2" 0001B (BAY B)

TRAILER TUBE C745 PIS 007B 1/2" 0052A 1/2" 0042A S

1/2" 0094A A

C746A A

C745 1/2" 0088A 1/2" 0003A 1/2" 1/2" 0049A RV-007A PISL 007A 1/2" 0001A (BAY A)

TRAILER TUBE C745 PIS 007A 1/2" SV 001B SV 001C SV 001A SEE NOTES 11 & 15 HYDROGEN GAS SUPPLY FACILITY 0100 1/2" WITH SCREEN VENT STACK 1/2" 1/2" 1/2"

" TUBING 1/2" 1/2" 001A LF 1/2" 1/2" 001C LF 001B LF 1/2" 0109 1/2" 1/2" 0108 003 LF 0110 1/2" 0106 1/2" 1/2" 0105 002 LF 0107 GAS SUPPLIER RESPONSIBILITY RESPONSIBILITY PECO 007 PCV 0111B 0112B 1/2" 1/2" 0111A 1/2" 1/2" 0112A 0111C 0112C 1/2" 1/2" 004A LF 004B LF 005B LF 007B PI 005A PCV 005A LF 007A PI 005C PCV 007C PI 005C LF 006A LF 006B LF 19.

SPARED PER ECR 00-01263.

PIPING SYSTEM TO BE GROUNED.

NOTE 19 NOTE 19 NOTE 19 NOTE 19 NOTE 19 NOTE 19 NOTE 19 NOTE 19 NOTE 19 NOTE 19 NOTE 19 9

14 11 FT 002 20.

RE-INCORP. ECR 00-01263 REV. 0. DELETED VENTS AND VALVES 0097A,B,C. [A,B,C-7].

INCORP ECR 03-00273 REV. 0. REVISED PURGE MANIFOLD DELETED VALVE 0097C, AND ADDED NOTE 20.

[B,C-4,5]

EJW JCW MSD 29 5

03 DELETED.

DELETED.

SV-001A,B,C; 0003A,B,C; 0042A,B,C DELETED.

PRAXAIR EXELON 1/2" 0115 0116B 0116A 1/2" 1/2" 3/4" 3/4" 002B PSV 002A PSV 1/2" 1/2" 0012A 1/2" 0072B 1/2" 1/2" 0091B PI 008B 0012B 1/2" 0072C 1/2" 1/2" 0091C PI 008C 0012C 1/2" 1/2" 0113C 0114C 1/2" 1/2" 0113B 0114B 1/2" 1/2" 0113A 0114A INCORP. ECR 12-00455 REV. 0 PER WO C0249176. REVISED OXYGEN GAS FACILITY.

[A-C,3-8]

12 M-06 (SHT. 9) 1/2" 1/2" 1/2" 28 10 13 EJW JCW TJ X

SEE NOTE 7 INCORP. EC 627708 REV.1. AND 630686 REV.3.

REVISED UNIT 1, 2 AND COMMON HWC PANEL UPGRADE-STRATEGIC CHEMISTRY PROJECT. [G,3]

13 07 5

21 AN AA GS 21.

ABANDONED IN PLACE.

ADDED NOTE 21 PER EC 630686 REV. 3. [F,1]

INCORP. EC 631205 REV. 0 14 K

M C

H G

S D

K 005B PCV X

5 4

22 1

A B

C D

E F

G H

C D

E F

G H

A B

SCALE CHECKED INSPECTED APPROVED DATE SHEET OF APPROVED APPROVED IGDS DRAWN MECHANICAL NONE USE ONLY PRINTS SHOWING LATEST DATE TABLE OF ADDITIONS & CHANGES DESCRIPTION DATE NO REV'D CHK'D APP'D 8

7 6

5 4

3 2

8 7

6 5

4 3

2 1

4/8/2022 PRINTED:

X:\Shared\NPG\EXELON\_LGS\A11322.258 DESIGNER-DRAFTER SUP CDO\4.0 Design Documents\4.01 Dwgs - Released\.09 Gen EXELON NUCLEAR CORP.