Rev. 21 to Updated Final Safety Analysis Report, Drawing M-0006, Sheet 9, Rev. 14, P&ID Hydrogen Water Chemistry System Unit 1, 2, and Common
ML22278A595
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A595 (1)


Text

8 7 6 5 4 3 2 1 8031-M-06 SH. 9 NOTES:

1. LINE CLASS DCD SHALL APPLY FOR 2 H & 2 O PIPING; PIPE IS SEAMLESS TYPE 316L SCH.80; FITTINGS ARE HYDROGEN WATER CHEMISTRY TYPE 316L STAINLESS STEEL; USE SCH.160 SEAMLESS MAIN ISOLATION PANEL PIPE FOR THREADED CONNECTIONS UNLESS NOTED OTHERWISE.

(BY GE) P73-P550 VENT STACK 20-S172 2. ALL COMPONENT NUMBERS THAT APPEAR ON THIS P & ID, WITH SCREEN SHEETS 9, 10 AND 11 ARE IN SYSTEM 006A.

PCV (F551) 3. GENERAL ELECTRIC EQUIPMENT IS SUPPLIED TO PECO H 210 SPECIFICATION NE-076 AND GE DESIGN SPEC. 25A5068. H C745

4. HYDROGEN DETECTOR FOR MAIN ISOLATION VALVE AREA.

A 1/2" 0049A 1/2" 1/2" 0100 1/2" 5. HYDROGEN DETECTOR FOR INJECTION POINTS AT REACTOR C745 M-15 FEEDWATER PUMPS.

C746A PISL PIS (SH.31 D,1) 6. *- SUPPLIED BY VENDOR.

PCV PCV-210 A

007A 007A 1/2" 1/2" 0094A 007 (A-S) 0001A RV-007A

7. X - DENOTES A PLC CONNECTION LF 1/2" (F552) XIC-06-100, 200 ARE PROGRAMABLE LOGIC SV CONTROLLERS (PLC).

001A NOTE 19 NOTE 19 S

001A 1/2" 1/2" 1/2" 1/2" NOTE 19 1/2" PI 8.

TO A H 2INJECTION LINE THIS REPRESENTS THE POSITIONER.

221 9.

M-06 NE GLOBE AND CHECK VALVES FOR OXYGEN AND HYDROGEN (R557) RV-251 0003A 1/2" 0042A 0052A SV SERVICE NOT SUPPLIED BY G.E. OR GAS SUPPLIER ARE (SH.11 G,4) (F555) CLASS ECD.

0112A 1/2" TUBE NOTE 19 1/2" C177 251 TRAILER (F554) C177 10. THE UNDERGROUND PIPING IS TO BE INSTALLED IN TO B H 2INJECTION LINE ZS (BAY A) XIC ACCORDANCE WITH SPEC. 8031-C-9.

M-06 S RG 0088A 200 251 11. DELETED.

0111A 1/2" (SH.11 F,4)

C745 12. HYDROGEN PIPING BETWEEN THE INJECTION MODULE AND TO C H 2INJECTION LINE X INJECTION POINT SHALL SLOPE 1/4" PER FOOT FROM THE X

1/2" A HIGHEST POINT OF THE PIPE RUN TO THE INJECTION G 0049B G M-06 SEE SEE MODULE AND TO THE INJECTION POINTS. (SEE GE NOTE 7 NOTE 7 DOCUMENT NO. (25A5068,PARA.4.1.1.1) 1/2" 0112B C745 (SH.11 E,4)

C746B PIS 13. 1/2" NPT SCH.80 MONEL.

PISL A

007B 007B 3/4" DELETED.

1/2" 14.

1/2" 1/2" 0001B 0094B RV-007B 0111B LF 1/2" 15. DELETED.

SV 001B NOTE 19 NOTE 19 S 2250 16. MONEL ASTM B-165 TRANSITION PIECE 10" IN LENGTH, 001B 1/2" 1/2" 1/2" NOTE 19 1/2" PI AFTER THE VALVE.

17. GENERAL ELECTRIC Co. MPL No. FOR THE HYDROGEN 211 WATER CHEMISTRY SYSTEM IS P73 THE DEVICES 0003B 1/2" 0042B 0052B PROVIDED BY GE ARE DENOTED WITH THE GE I.D.

RV-254 NUMBERS IN BRACKETS.

1/2" NOTE 19 1/2" TUBE TRAILER 18. PIPING SYSTEM TO BE GROUNED.

(BAY B) 0088B 19. SV-001A,B,C; 0003A,B,C; 0042A,B,C 3/4" DCD-201 3/4" 3/4" 3/4" SPARED PER ECR 00-01263.

C745

20. DELETED.

2252 2251 0112C 1/2" A 21. ABANDONED IN PLACE.

1/2" 0049C XV HV C745 251 C746C 202 0111C 1/2" PISL PIS A

007C 007C 1/2" 1/2" 0094C 3/4" 3/4" 3/4" DCD-201 FC 0001C RV-007C LF 1/2" M-06 F F 001C NOTE 19 SV NOTE 19 2248 2249 3/4" S 1/2" (F556) (SH.11 E,8) 001C 1/2" 1/2" 1/2" NOTE 19 1/2" 3/4" 2247 UNIT 1 UNIT 2 0003C 1/2" 0042C 0052C THIS AREA TURBINE TURBINE 1/2" TUBE IS EXCLUDED ENCLOSURE ENCLOSURE TRAILER FROM NOTE 4 (BAY C) 0088C HYDROGEN WATER CHEMISTRY 3/4" DCD-201 N2 PURGE, MAIN ISOLATION PANEL TEST & SAMPLE ROOF (BY GE) P73-P550 HYDROGEN GAS SUPPLY FACILITY 10-S172 SEE NOTES 11 & 15 2" PCV 2299 3/4" 3/4" 3/4" DCD-101 (F551) 110 TO "A" H INJECTION LINE TO "B" H INJECTION LINE TO "C" H INJECTION LINE 3/4" DCD-001 3/4" 1253 10C177 2" DCD-001 2253 1/2" 1/2" PALL 2 2 2 (SH.10 G,4) (SH.10 F,4) (SH.10 E,4) 010 M-15 PI M-06 M-06 M-06 (SH.31 D,1) PCV-110

" TUBING 3/4" 1250 3/4" 1251 111 (A-S)

X (F552)

E RV-154 SEE C745 E NOTE 7 1/2" PIS 1/2" 010 PI 0030 1/2" 3/4" 3/4" 121 0055 3/4" RV-151 NE (R557) (F555) SV 1252 151 0029 3/4" C177 PISLL (F554)

XIC 010 H2 SUPPLY TO UNIT 2 S 1/2" 1/2" 0056A GAS SUPPLIER PECO 0057A 100 RV-010 1/2" FOI 001 RESPONSIBILITY RESPONSIBILITY 0024 C177 PI 3/4" ZS PI RG 001A PCV 151 X 001A 002A SEE RV-001A RV-002A 1/2" 1/2" 3/4" LF ABOVE BURIED ABOVE NOTE 7 FT PI X 004A 1/2" 1/2" 001 3/4" DCD-001 TEST 0061 0007 PSV 1/2" SURFACE SURFACE 005 001 3/4" 1/2" RV-005 HV 1/2" 3/4" XV XV 0005 0101 0034A 151 0033A 001 LF LF 103 1/2" 1/2" 1/2" 002 003 1/2" SEE NOTE 10 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 11/2" 11/2" 3/4" 3/4" 3/4" 3/4" 3/4" DCD-101 FC D D FE M-06 1/2" 1/2" 0056B 0057B 001 0105 0106 0060 0062 0064 1/2" 0065 0066 0108 0109 0009 11/2" DCD-001 3/4" 0022 1299 1248 1/2" 1249 (F556) (SH.10 E,8) 1/2" 1/2" 1/2" 1/2" 11/2" DCD-001 3/4" DCD-001 0008 3/4" DCD-101 0033B 0034B 1247 3/4" 3/4" 1" DCD-004 PI PI 1/2" 1/2" PCV FLUSH 0011 001B 002B 11/2" 001B CONNECTION 0107 0063 0006 0110 1" RV-001B RV-002B LF 1/2" 1/2" WELDED 004B (CONSTRUCTION)

SEE NOTE 18 N2 PURGE N2 PURGE, TEST & SAMPLE 3/4" BURIED FUTURE FROM YARD UNIT 1 H STORAGE TANK 2

TURBINE SURFACE ABOVE ENCLOSURE 1/2" 0069A SEE NOTE 4 HYDROGEN COOLING (SH.01 B,8)

C TO GENERATOR C

0012A M-28 PI 1/2" 008A PI RV-013A LF 007A 1/2" 005A 1/2" 1/2" 1/2" 0072A 0091A 1/2" 1/2" TUBE 0114A TRAILER (BAY A)

PCV 005A C177 0113A 1/2" PALL 016 1/2" 0069B SEE PSV PSV INCORP. EC 631205 REV. 0 1/2" 0114B 0077A X

1/2" 002B 002A FOI NOTE 7 4 C K 002 5 G 14 M D H

0012B 22 PI 1/2" C747 K S 008B PIS PI PCV PI VENT RV-013B 0113B 1/2" 007B 1/2" 016 002A 004A 3/4" 3/4" LF INCORP. EC 627708 REV.1. AND 630686 REV.3.

RV-004A 1/2" 13 5 1/2" 005B ABOVE ABOVE 0075 LF BURIED YARD UNIT 1 TURBINE 07 REVISED UNIT 1, 2 AND COMMON HWC PANEL AN AA GS 1/2" 1/2" 1/2" 1/2" 1/2" 006A 1/2" TEST 1/2" 21 UPGRADE-STRATEGIC CHEMISTRY PROJECT. [G,3]

B B

0081 ENCLOSURE 0018 SURFACE SURFACE ADDED NOTE 21 PER EC 630686 REV. 3. [F,1]

1/2" 0115 1/2" PRAXAIR EXELON 1/2" 0072B 0091B PISLL FT TUBE 016 1/2" 0116B 0116A 002 1/2" XV 10 INCORP. ECR 12-00455 REV. 0 PER WO C0249176. REVISED 0016 TRAILER 12 RV-016 28 OXYGEN GAS FACILITY.

1/2" 0038A EJW JCW TJ 0037A (BAY B) 002 13 [A-C,3-8]

PCV 1/2" 1/2" 005B 1/2" RE-INCORP. ECR 00-01263 REV. 0. DELETED VENTS AND 1/2" 1/2" 1/2" 1/2" 1/2" 2" SEE NOTE 10 2" DCD-002 2" DCD-002 5 VALVES 0097A,B,C. [A,B,C-7].

FE 11 M-06 INCORP ECR 03-00273 REV. 0. REVISED PURGE MANIFOLD 1/2" 29 EJW JCW MSD 002 0077B 11/2" 03 DELETED VALVE 0097C, AND ADDED NOTE 20.

0020 0080 0082 0084 1/2" 0085 0086 0087 (SH.10 B,8) [B,C-4,5]

1/2" 0069C DATE REV'D CHK'D APP'D SEE NOTE 18 0114C 1/2" 1/2" 1/2" 1/2" 0019 0037B 0038B 3/4" NO 0102 PI DESCRIPTION 1/2" 1/2" PCV FLUSH 0012C 0021 1/2" 004B PI 002B 0083 0017 2" CONNECTION RV-004B 1/2" 008C TABLE OF ADDITIONS & CHANGES PI WELDED RV-013C LF 0113C USE ONLY PRINTS SHOWING LATEST DATE 1/2" LF 007C 1/2" (CONSTRUCTION) 006B 005C 1/2" N2 PURGE MECHANICAL 1/2" 1/2" 1/2" FUTURE FROM P & ID (SHT. 9) 0072C 0091C O STORAGE TANK TUBE 1/2" 2 HYDROGEN WATER CHEMISTRY SYSTEM TRAILER UNIT 1, 2, AND COMMON (BAY C)

PCV A A 005C LIMERICK GENERATING STATION EXELON NUCLEAR CORP.

SCALE DRAWN IGDS CHECKED INSPECTED APPROVED DATE OXYGEN GAS SUPPLY FACILITY PRINTED:4/8/2022 NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 2/27/96 M-06 APPROVED BECHTEL APPROVED R

SHEET 9 OF 8031-M-06 E V

14 8 7 6 5 4 3 2 1 CATEGORY A1 X:\Shared\NPG\EXELON\_LGS\A11322.258 DESIGNER-DRAFTER SUP CDO\4.0 Design Documents\4.01 Dwgs - Released\.09 Gen