ML22278A575
| ML22278A575 | |
| Person / Time | |
|---|---|
| Site: | Limerick |
| Issue date: | 09/19/2022 |
| From: | Constellation Energy Generation |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML22278A223 | List:
|
| References | |
| Download: ML22278A575 (1) | |
Text
N
- c
~
Ln I
~
H G
F E
D c
B A
8 8031-M-15 SH. 2 OF 7
6 5
4 3
c=:=========================~--------i INTERLOCK COMPRESSOR *~
I I
MOTOR START
~
-f (SH.1 D,3)
AC C655 I
I hlhl-C855 1----~~:_-1-_J
~~48A--
PS ci48A I
r-.F---....,,,,_ __ _,,._ __ _,,.__ __
-no~---Jl'----#----11'!-~*-_,,,._ __ _,,._--,
101
-+-~11~1.+:::...F---'--....,,,,_--'-_ _,,,,_-DIG-"'-.l"--'-----,1'---.---.l'---f
~cfu~C~R I 1:. I - -f I
- c'i,,sA C655 0___
~
CB55
~
PT IZOA
- PSL llOA 1------1 Pl 184A WATER
<:.JE!JG~ii3'j,;J0011lii-ii11iiosi&.-.,
TREATMENT*
M-15 ENCLOSURE ISH.5 C,2)
INTAKE Fii:TER" IAF104*
COOLING WATER HIGH TEMPERATURE
- M-14 (SH.I 0,4)
I~
TO TURBINE <:::1i:}]Cip~3'~J~D~0-~1~0~8-... _..,,..mj.;;. if-.!..' O;o:
ENCLOSURE
- M-15
""'l~""'I INS~~ ISH.G G,Bl HEADER 'A' 1019A 1924A 1'1;1\l~IE < M-15
. )
HEADER 'B' <SH.3 B,Sl 8
3' J00-1081 3' 1026 LC NOTE 3 J
I 1----- -~-=-t--~....,,,,_~_,,._~_,,._~--J<-.~...,P.--~__,p.--~----~-------1.~-'--:.~~,p-~,p-__,-
-,#'~~~**~
L-1----- ----------,
NOTE3 1774 A
~-1-----
---1 I
t--,-1---
-r I
HIGH AIR I
r---- 1---- -
TEMPERATURE I I I L __ _j____
I t-I I Cl48A I
I I 1 I
I I~
I TCV-14-103A
- M-14
!SH.I C,41 INSTRUMENT AIR COMPRESSOR 1AK101*
J4' JB0-335
~*
'A' RB0-115~,l, E/S J4* RBD-115 C148A LG
- 101
,___..,.,..,,.,., C148A 0
- l INTERCOOLER 0 "'
a:
~
C130*
~
INSTBUMENT AIR DRYER AFTER-FILTER 1AF102 2'
1909*
INSTRUMENT AIR DRYER AFTER-FILTER
~
ow VENT 1921A 6' JBD-156
<o
=~
~n I
I
_J
~
~
1----~-**-J_s_o-_3_35 __ _
o~
~
w JB0-335
'Y 'Y NW NW EXH.
lW RBD-115 COOLING WATER A
4' AFTERCOOLER
- INSTRUMENT AIR AFTERCOOLER &
MOISTURE SEPARATOR IAEllJ*
M-15
~C855
~
MOISTURE SEPARATOR*
ISH.31 H,Sl LT-102AIAS> %' JBD-335
%* RBD-115-Y.' JBD-335
)4*
___ l1.~~1A
~
~* JS0-335
--w
- 'RBD-115
!i=
_j!_
~
NW PILOT AJR lDE INSTRUMENT AIR FILTER/DRYER PACKAGE '1A' *
<SHOWN WITH CHAMBER IAF116 DRYING AND RBD
- R 4'
J4' RBD-115 4'
3' 1008A INSTRUMENT AIR RECEIVER
'Y NW J4'J80-335
=-1---------.
E/S MOISTURE SEPARATOR 14'-0' LONG>
I I
I I
I I
I I
I VENT m
0
~
~
~
~
TO PV-15-167 L-----------------------------------------------------------------------~~~~-~~~'~-~~~~~~---------------------------------------------------------
7 6
5 4
3 SERVICE Affi SUPPLY INTER TIE 3' JOD-107 INSIBUMENT AIR DRYER PRE-FILTER
~
2 18!18A
_____________________ _J NW 2
UJ Ot-z <(
0 DESCRIPTION TABLE OF ADDITIONS & CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL P&ID COMPRESSED AIR
<INSTRUMENT AIR COMPRESSOR 1 A, UNIT 1 l H
G F
E D
c i------L-IM-E-RI-CK_G_EN_E-RA_T_IN_G_S_T_A_TI_O_N ___
1 A EXELON NUCLEAR CORP.
SCALE DRAWN
!GOS CHECKED INSPECTED APPROVED DATE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 08'28189 APPROVED-BE_CH_T_E_L ______ APPROVED---------1 SHEET 2 OF 8031-M-15 45 I CATEGORY Al
_J