ML22278A554
| ML22278A554 | |
| Person / Time | |
|---|---|
| Site: | Limerick |
| Issue date: | 09/19/2022 |
| From: | Constellation Energy Generation |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML22278A223 | List:
|
| References | |
| Download: ML22278A554 (1) | |
Text
I-I
(/)
~
(.0 I
- E H
G F
E D
c B
A 8
8031-M-16 CONDENSATE TRANSFER SYSTEM HS I'll!
M-OB 4"JCD-00B SH.3 OF C651 PCV 101 CSH.2 G,21 13B81 138'l N
iii
- la r.,
J~D 5420 PAL 132 PSL 132 Pl 132
~*
NOTE PAL
,~33 1/PSL
,,133 I/'
Pl 133.
~I---<
' c TO DRAIN COOLER 7
TO SAMPLING PAtEL M-23 INLET HEADER 31!" GBD-116
~
L.!.J DRAIN M-06 CSH.1 8,7>
5420 p
126 PAL
- 126
- 5420 F
142 I
'11--->
- ---1_..J
- I 5420 FAH' FAL
,..J42 142 LJ 12" GBD-116 M-011 CSH.2 F,31 11B 1
17,!I 1"
1466
~*
r---llf---:J VENT 1*
DRAIN['.:--..,. >-"""7-1 1440
~* HCD-13 1468 6
118 !BO HV l'l2 NOTE 20 M
N"""
CB4l
~~*
~-~
ll8118,!I 1*
1465 TO SAMPLING PANEL 1"
I" lf--:JDRAIN M-23 1436 1437 4" HCD-135 CSH.B H,71 5420
~
~
I"
~M<Xl ~:!:;;,__--1*-:J
!424A I" GBD-17'l 0
~
- ,.cl.., 1 <C
-z~~$
FROM SOLENOID VALVES MOUNTED IN PANEL 10S416 NOTE 5 14" HIS *OW IA,21 3"HCD-135 AIR/CONDENSATE TRANSFER HEADER FLOW CONTROL g:
*--311'"""""'11r""""""'T1~1-1oor--1r-1r--D
&. BALANCING 7
l" 150oF '"
B C
D E
F G
H SYSTEM
~........ -j,;~L-f!::J_
5 I*
~
- PSV llBA 2" DISCHARGE FOR PSV-llBA,B,C,E,G,&.H 2" GBD-183 4" GBD-IBl HIS -0 IB,BI 2" HCD-135 NOTE 15 HV 441 3" GBD-IBl SY
'141 iii g -"'
1
- c CU31 HV 442 HV-440CAS-ll
- .J
"""'"-;,M;-_,-;tt;,...--.)--.r<-j)IJ-~:J-->F-'
j_
13'l5A CD
<Xl
~ ~
M N ZS 1B3A
'---'-**-**-**-**J I
3" 3" GCD-101 IO 14721!i CONDENSAT I
C31 6".0 --"-I SAMPLE PORTS BLlf<<l FLANGED l'lll° APARTI PEMINERALIZER VESSEL
!ATq27 CTYP. OF Bl
..!:. :i I CSH.6 G,5) i::-3-* _Jc_o_-_14_2_.,-t------------
I--.,, B
_..,, c
..._..,, D
~~ :J
_[
13'l5B
['. 3" JCD-142 i->
E 1--..,,F -
t--..,, G Cl
..._..,, H
~
CD -
' al f "";~~:t:iw_.. _
- 186A
- 6" i
CRAI HV 186 L-*-**-**-**-** -**-.. -**-.. -**
I 3" HY 184A CVA@
L **-. *-**-**-**-**-*
151 -'
Cl u
i->
3' GBD-184 RESIN FILL CONN.
SEE NOTE 16
"' -' la i->
CRW CD ffi ~
B 3" JBD-383 g: -'
~
c 1cTq21 Cl z
4 D
1pTq27 3
30" CONDENSATE EFFLUENT 30"-GBD-1B0 30"CONDENSATE INFLUENT E
3" VENT HEADER 3"
!ETq27
~*
F 30" GBD-17'l G
NOTES 3, 7 &. 13 DEEP BED DEMINERALIZE CONTROL CONSOLE 105420 I
TROUB~E C305 XA 101 4" JBD-3B B
C D
E F
G H
3"JBD-3B3
!FTq27
!QTq27 10" GBD-1B2 5420 VENT ('.--fllt--, I- -
14" CTYP.I H
'Y DRW
!HTq27 i->
NOTE 15 r.,
5420*
..J
..J
([,.
Cl
..J
'------._;1.;.6-1" '*.l----"'T'"...L(>--[Xl--f....-'1"10'°T*----.;.14°"!4:f.2:"A_.. -----.,.*
12*
1414A 13'l1A
'---fll~lf* -....C:(;~t---l>~O--.
S420 *
~~~*.
AIR HEADER H
G F
M-15
!SH. 6 G,7 HIS OW CE,7>
DRAIN TO BACKWASH REC. TK. VIA HBD-166 M-16 CSH.l B,81 FROM FT-146AIB-Hl 5420*
I E
HY 423 D
Gil
~
c L..---------1 3" JBD-382
!lo!." SBD-116 I
~* SBD-116 I
L-----------_J TO
<::J~~~---<
SAMPLING*
M-23 PANEL CSH.8 H,1>
6" RINSE HEADER HV 443 4" GBD-lBI CRW DRW iii -'
~...
2" GBD-181 4" GBD-lBI
~
~
3"GBD-181 4" GBD-!Bl 1-----=-------.
1*
1453145&
~i__M ~
ra1 -
- J DRAIN
~
- c i->
~*
H]l-flJt-".:J VENT
_,-1" SBD-116 6" GBD-lBI
-III--~}-;,.*. ~
Y PT 14 71*
VENT VENT ZI FIC'
_ _J 103 r.l r.l
\\.152,, 152 I
I S4~lj iii Pl 103
~1---------
6" HBD-160 i'o 8
l" HBD-735 7
!ii L.!.J DRAIN M-23 ISH.8 B,21 THIS *OW IG.71
- i:
~
3" GBD-180 L.*-**-**-*
"' 9 s*
'!;' 1-...,. B IY)I'""
~
EL. 217'-0" HV l'l5. -
L.!.J DRAIN DRAIN [-
1413A
~-'""*
Pl 125A 1443A LAYUP PUMP 13000 GPM 11 50 'TDHI
~*
VENT ['.:..._--a... --.
1442B 12*
I*
1--1>----l><l-+~
~*
13'llB 10" 1413B L:::.~.-Jlllll--:J DRAIN l443B LAYUP PUMP !BPq30 iA 1-...,. c z
1so 1
18,!i L~~~~~~~~~~~__.!~~4.*~~~----1 4*
4" GB0-182
-.r-
- ~
~.......,.a i5
~
E z t-'"I' F 0:
.......,. G
......... H S420 POI
- 22
~*
- 122, r., -
~ -
Cl
~
~ -*
Cl
~
i->
TO SAMPLING PANEL M-23 ISH.B H,61
' r., -
1~0 118,!i
~*
FLOW CONTROL J.._ ~
14 76A
&. BALANCING r-~-.!f SYSTEM ND
- 5 T" ___ J FCV NOTE 14 NOTE l'l-146A DRAIN r.l
~
N
([
Nm)I---'
1*
I" GBD-185
--iei----~----
1407 A 14" B
C D
E CD -,_
' z c "'
iii<.
DRW
\\~--~r--~/
v TYP. FOR "B" VESSEL B
C 1" GBD-1B5 D
DRW
\\..__~~---
v TYP.FOR VESSELS E &. F AND G &. H c
24" D
F G
H D
3*
1" I"
- .._4****~~,__..._......_....... _.,__ _______ --.-____.-_.._......__._ __
1--*~***-:J l44B 3"
SPENT RESIN HEADER 3" HCD-136 1450 NOTES: (CONT. FROM B,C-1 &. 21 16.BLINO FLANGE IS INSTALLED BETWEEN FLANGES TD ISOLATE 3"GB0-184.
- 17. VALVE 1406 MUST REMAIN OPEN DUE TD PSV-115.
- 18. INSTRUMENT CALCULATES REMAINING VESSEL RESIN CATION REMOVAL CAPACITY CTYP. OF Bl.
l'l. THE MOTOR OPERATOR FOR THE DEEP BED DEMINERALIZER FLOW CONTROL VALVES WILL BE NORMALLY DE-ENERGIZED PER ECR 'l'l-009Bl.
- 20. THE MOTOR OPERATOR FOR THE DEEP BED DEMINERALIZER HEADER BLOCK VALVES WILL BE NORMALLY DE-ENERGIZED PER PROCEDURE 516.1.B
- 21. REFER TO HIGH LEVEL FUNCTIONAL BLOCK DIAGRAM W-120-VC-00005 FOR FEEDWATER LEVEL CONTROL SYSTEM. CXC-006-150-1,-21 6
L.!.J EL. 217"-0" EL. 200'-0" 5
E VENT r.l F
13'l0 S420 *
~
~
12" CTYP.I G CD -'
~
PT 124 H
30*
30" GBD-IB0 1006 S0LENIOD PANEL CTYP. FOR 1A5414-IH54141 M-15 OIH>'C: 1--f"-::-:_:::_:-: __ ::_::-__ ::-:,;--,
CSH. 61 1A-S414CASI PANEL TO SPENT RESIN TANKS M-16 ISH.4 G,21 4
1A5414 NOTE 'l-:
.-l.
HV-IB2A -#-t-SV-182A HV-184A SV-184A HV-IB3A SV-183A HV-IB5A SV-185A
[- SV-lBBA*
HV-IB7A -#-t-SV-187A HV-IB6A SV-186A
[:- SV-425 DRAIN.
CTYP.1 SPARE/CLOSE 1*
1*
L.--t*---1*-:J DRAIN 43B 143'l 2005 M-15
!SH. 7 H,51 10-S4151ASI PANEL 1054~)
NOTE 10/'l-HV-1'l5CAS-llT---...,,b 0
HV-l'l3 HV-l'l5 HV-423 HV-424 HV-l'l4
-H-+- SV-l'l3T SV-l'l~J r
- -l-SV-423 Q
-#-l-SV-424
-#-+-- SV-l'l4
._____,~,or-1' HV-l'l5CASl 3
N -
1006 HV-l'l6 151 Cl
~
ill 2
2 iii g
1
- c 1
NOTES:
I.
- SUPPLIED BY GRAVER.
- 2. ALL INTERCONNECTING PIPING SUPPLIED BY PECO.
- 3. ALL FLOW, PRESSURE DIFFERENTIAL, PRESSURE, LEVEL, AND MOTOR/AIR OPERATOR SIGNALS WILL GO TO LOCAL CONTROL PANEL AND PROGRAMMABLE LOGIC CONTROLLER.
'I. GRAVER ASSIGNED TAG NUMBERS FOR GRAVER SUPPLIED DEEP BED DEMINERALIZER EQUIPMENT ARE NOTED IN PARENTHESES NEXT TO BECHTEL ASSIGNED NUMBERS FOR REFERENCE.
- 5. THIS REPRESENTS THE VALVE POSIT IONER.
- 6. l/D CABINET SOLENOID VALVES ARE NORMALLY CLOSED WHEN DEENERGIZED.
- 7. INSTRUMENTS LOCATED IN 10S420 ARE PROGRAMMABLE SOFTWARE.
B. ALL SOLENOID VALVES ISVI, POSITION SWITCHES CZSl, AND AIR OR MOTOR OPERATED VALVES CHVI, EXCEPT HV-16-l'l0 ARE CONTROLLED BY THE ALLEN-BRADLEY PLC SOFTWARE.
'l. SEE DRAWING B031-M-l'l6-16-lll FOR AIR SUPPLY DETAILS FDR PANELS 1A5414 TO IH5414.
- 10. SEE DRAWING B031-M-l'l6-18-lll FDR AIR SUPPLY DETAILS FDR PANEL 10S415.
- 11. SEE DRAWING 8031-M-l'l6-40-lll FOR AIR SUPPLY DETAILS FOR PANEL 105416.
- 12. PANEL MOUNTED AIR SUPPLY SHUT-OFF VALVES ARE IDENTIFIED WITH SUFFIX "IASI" TO USER TAG NUMBER, EXCEPT AS NOTED.
- 13. ALL DEEP BED DEMINERALIZER CONTROL CONSOLE ALARMS ARE ECHOED BY XA-16-101.
I CONT. BELOW l
' c VENT i->
TO TEECE REFILL OVERFLOW TANK 10Tq2q
~
iii '
Cl
~
Cl i->
~
2it..* 2*
"' :c I!!
zit..* 2\\.!," JBD-383 2~*
1420 2" JBD-383 FG FLOW CONTROL I BALANCING SYSTEM (TYP. OF Bl C651
~
I I
FROM r -,-_ t- __ -o-- __ ~ __ -t-;7,.";:+;';~';7-:;;'i FT-14611 I
I I
I 161 CRW
~_J FR 5420 I I
s420 I ~* I I
~ 146 I
I I
-l TD/FROM FCV-146A I
1-------,
I I
5420
- I I
I
+.----t TO FIC-152 I
I S4Q:a~
S420 I
FY FROM FT-146B
~--_J 146 ---t THRU FT-146H I
I*
- 5420 FAH Fl
- SYSTEM INFLUENT 146, "146 CONDUCTIVITY.
5420
§v;:;3o a) _____ __f&i_ _______________ _J
!SH. B A,Bl
~
NOTE 18 I
- ~S420 Al 146 NOTES: I CONT.>
- 14. NOT USED
- 15. PLC SEQUENCE COMMANDS TO OPEN VALVE HV-16-402 OR HV-16-187A-H WILL CLOSE VALVE HV-16-43'l PRIOR TO OPENING HV-16-438. PLC SEQUENCE COMMANDS TO CLOSE VALVE HV-16-IB7A-H WILL CLOSE VALVE HV-16-438 PRIOR TO OPENING VALVE HV-16-'13'l.
!CONT.AT A-5 &.61 INCORP.EC 828906 REV.O H
G F
E D
c C MK
~ F ~ B TO HV-403 HIS OW IG,51 INCORP.ECR LG 09-002'l5 REV.0.CHANGED DISCHARGE SIZE OF PSV-118A,B,C,E,G,&H FROM 1" TO 2" I IF.61.
INCORP.ECR LG 04-00682 REV.0.ADDED AIR SUPPLY VALVES AND PRESSURE CONTROL VALVES TD PANELS llA-Hl-5414, 10-5415, AND 10-S416. IB-2,3,41.
INCDRP.ECR 03-000B5 REV.0 PER WO C020725'l.AODEO 12 XY-006-150-003 &. -Al5 AND XC-006-150-1,-2, AND NOTE 21. H,7-Bl, !A,5-61.
w
~ ';;;:
DESCRIPTION Cl TABLE OF ADDITIONS &. CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL SCALE NONE P&IO CONDENSATE FILTER DEMINERALIZERS AND DEEP BED OEMINERALIZERS
!UNIT 1l LIMERICK GENERATING STATION EXELON NUCLEAR CORP.
DRAWN IGDS CHECKED INSPECTED APPROVED DATE JVM JVM ORF WRJ APPROVED WRJ FOR R.R.HESS A