H G

F E

D c

B

~ A

c

!D t.n

~

8031-M-*15 SH. 11 OF OUTBOARD MS!V FILTER 1AF264 Z"

2'X1' 7

6 Z'x I" 2'

2'JDD-10B

'Z' ISH.J4H,S>

5 4

OUTBOARD MS!V FILTER 18F264

  • ~

~~ENT CSH.2G,4) 3 2

2"JOO-IOEI

~~ ~

'"t%:'X1' 142:

CRD 1-Q-!

I J~

0

,!!Br266 tSH.1 E,8l


1 HY-46-1'5B l!J I

I

1

£1 I

~J SPARE SPARE,,,

ELEV. 25;!'._*_0~

L _____________________________ _

i~~~1~;J~g~?SURE2]M-E[i*C>---"--""""'"'----"'"EAIJ=ER:....'"-B'-,

CSH,340,1}

CSK.34 G,U

-*---1°--11---------------

2' JOO-IOB HEADER'S' G~4 E~>~ ;__-..,.----------,.----r-'-=--------r-----""T=------.----.,."!"'""--......,~------......,~---r"!"'""----i.------------r---.,-----'~,1.,>,.-,-~,~

  • . ~01-.0-1 -1'-J-,

~ ~ J CSH.2G,7) 1282.13.03 :!DRAIN l __ ISH.34C,2l- - -- ---- -

i-------------

1 I

I I

I I

I I

I I

I I

I I

I I

I l!J DRAIN (SH..2 G,51 1119.02.D2~DRAIN L!..I SPARE lSH.3G,.61 SPARE HV-C-51-1038

<SH.4C,5l 1282.07.03 ::JORAIN cs:~ o;n ZSIXV-22-110~

1

"----1--jOl!.tIN 1282.01.04 I

~ZS/XV-22-1281

'IZBZ.01.03 !SH.SE.Tl ELEV.ZH' 1282.01.02 ::JORAIN

~ZS/XV-22-173 I ISH.10 D,7)

I

"-----1-28*1'*,.os-joR.iN I


~---------------------------------------------------_J L!J S_f'A~E __

L!..I SPARE HV-1H011F CSH.3F,.6l joRAJH 1119.08.02 2'JDIHOS IEADER 'B' FIC-52-129 ISH.2 G.5>

ISH.3 D,7)

SPARE jllRAlN 1119.16.03 CSH.2C,.51

JORAIN 1119.16.02 CSH.ZE,61 jORAJN 1119.1.05

- NOTES REFERENCED ON THIS SHEET ARE LISTED ON SHEET 1 -

INCORP. ECR 97-02128 REV.2.

15 CHANGED CONN. FLAG FOR XV-22-121i, 170, &. 173 TO W-22SHT.10.(().2l.CF.Sl.

INCORP. ECR '33-0Z3'35.

ADDED CONN~ION TD TIP DRIVE MECHAHISM !F.6J INCCRP'D.IMOD.*6221-HICCN 'F',

13 T ERRF'S L-2872,.2899 & 2908.

AOOEO CONT.FLA.GS TCl M-12 SH.2 LB-41.

DESCR!PHON COMPRESSED AlR

~=_:

<SH.3 c. 7)

~=:

P&.ID M-IS 2' J00-1oe

~v-c-st-tFo53A

<INSTRUMENT AIR: REACTOR ENCLOSURE, UNIT 1l

csH.34 s.a1

'mtr~li'.

~"""

u~~a~~~~~:: c~~~rnN I

L -------------------- ~*~IN-~119A.~0~ RAIN~~,._

... _ ** o_' - - -- - - -- - - -- - - --- - - -- - - -- - - -- - - -- - - -- - - -- - - -- - - -- - - -- - - -- - -

ELE~.. ~77' - o* - - -- - - -- - - _,,,_

  • .,_7.04_ :i_DRA_'"_ - - _J t-"~-+o*""*c'°"HT"-EL+.,,,BE;o,CH=TE""L +-~=.CHT=CKED=EL'-+":5"=",CH""';'""::"+BE""APCH"'PRll-r,~"'~'-+",11"'11~1.

APPROVED BECHTEL SHEET 11 OF 8031-M-15 16 8

7 6

5 4

3 2

I CATEGORY A 1 H

G F

E D

c A