Official Exhibit - ENT000048-00-BD01 - 0700.104-02, Revision 2, Indian Point Energy Center Unit 2, FAC System Susceptibility Evaluation (SSE)
ML12338A417
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 10/14/2011
From: Doremus R
CSI Technologies
To:
Entergy Nuclear Operations, Atomic Safety and Licensing Board Panel
SECY RAS
References
RAS 22101, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01 0700.104-02, Rev 2
Download: ML12338A417 (178)


Text

United States Nuclear Regulatory Commission Official Hearing Exhibit Entergy Nuclear Operations, Inc.

In the Matter of:

(Indian Point Nuclear Generating Units 2 and 3)

ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #: ENT000048-00-BD01 Identified: 10/15/2012 Admitted: 10/15/2012 Withdrawn:

Rejected: Stricken:

Other: ENT000048 (S I TECHNOLOGIES, INC.

Submitted: March 28, 2012 Consulting Engineers REPORT APPROVAL COVER SHEET Document Title: Indian Point Energy Center Unit 2 FAC System Susceptibility Evaluation (SSE)

Document No.: 0700.104-02 Client: Entergy Nuclear Project No.: 0705.111 This report has been prepared in accordance with Section 4.4 of the CSI Quality System Manual, Revision 2.

~...........:;....-~_-==--_ _ _ _ _ _ Date: '0;' r J /11 I

Verified:

-~~------~~~-----------------

Date: IO;1~;1

, , ,

Approved: ~'""=-~.::.....-=--=-_ _ _ _ _ _ _ _ _ _ Date: Ie IN/I(

Approved: __________________________________ Date: ______

Ian D. Mew (lPEC)

( SI TECHNOLOGIES, INC.

ConsultilZg Engineers Revision Control Sheet Project Number: 0705.111 Project Name: IPEC FAC Support 2011 Client: Entergy Nuclear Document Title: Indian Point Energy Center Unit 2 FAC System Susceptibility Evaluation (SSE)

Document Number: 0700.104-02 Rev. Date Description of Changes CSI Client Approval Approval 0 1211112009 Initial Issue- For Use B. Trudeau I. Mew I 112212010 Revision to incorporate new system list - For Use B. Trudeau I. Mew 2 10114/2011 Revision to incorporate replacement history - For Use f(.. Do~""tJ

Indian Point Energy Center Unit 2 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-02 Revision 2 Issued For-Use October 14, 2011 prepared for:

Entergy Nuclear Indian Point Energy Center 450 Broadway Buchanan, NY 10511 prepared by:

CSI TECHNOLOGIES, INC.

1 Douglas Ave., Suite 300 Elgin, IL 60120

Copyright © 2011 CSI Technologies, Inc. All rights reserved.

The information in this document belongs to CSI Technologies, Inc. It may not be used, reproduced, or disclosed without the written approval of CSI Technologies, Inc.

Disclaimer and Limitation of Liability CSI Technologies, Inc. (CSI) has made efforts to ensure the accuracy and completeness of the information in this document. However, CSI makes no warranties of any kind (whether express, implied, or statutory) with respect to the information contained herein. CSI assumes no liability to any party for any loss or damage (whether direct or indirect) caused by any errors, omissions, or statements of any kind contained in this document.

Further, CSI assumes no liability arising from the application or use of the product, service, or results described herein and specifically disclaims any representation that the products, services, or results described herein do not infringe upon any existing or future intellectual property rights. Nothing herein grants the reader any license to make, use, or sell equipment or products constructed in accordance with this document. Finally, all rights and privileges related to any intellectual property right described herein are vested in the patent, trademark, or service mark owner, and no other person may exercise such rights without express permission, authority, or license secured from the patent, trademark, or service mark owner.

Trademarks CSI Technologies, Inc., the CSI logo, and other trademarks, service marks, and logos are registered or unregistered trademarks of CSI and its subsidiaries in the United States and in foreign countries. Other trademarks and service marks in this document are the property of their respective owners.

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Table of Contents 1. INTRODUCTION ...............................................................................................................................................2

2. PURPOSE ............................................................................................................................................................3

3. SCOPE ..................................................................................................................................................................4

4. ASSUMPTIONS ..................................................................................................................................................5

4.1.GENERAL ASSUMPTIONS ................................................................................................................................5

4.2.SYSTEM, SUBSYSTEM, AND LINE SPECIFIC ASSUMPTIONS ..............................................................................5

5. METHODOLOGY ..............................................................................................................................................7

5.1.SUSCEPTIBILITY EXCLUSION CRITERIA ..........................................................................................................8

5.2. SUSCEPTIBLE NON-MODELED (SNM) CRITERIA .......................................................................................... 11

6. RESULTS ........................................................................................................................................................... 13

6.1.SYSTEM SUSCEPTIBILITY EVALUATION ........................................................................................................ 13

6.2.SUBSYSTEM SUSCEPTIBILITY EVALUATION .................................................................................................. 13

6.3.LINE SUSCEPTIBILITY EVALUATION ............................................................................................................. 14

6.4.COLOR-CODED FLOW DIAGRAMS................................................................................................................. 16

6.5.REVISION HISTORY ....................................................................................................................................... 16

6.6.INDUSTRY FAC EXPERIENCE TABLE ............................................................................................................ 16

6.7.FAC-SUSCEPTIBLE LINES CONTAINING ORIFICES ........................................................................................ 16

7. REFERENCES .................................................................................................................................................. 18

APPENDIX A: SYSTEM SUSCEPTIBILITY EVALUATION REPORT APPENDIX B: SUBSYSTEM SUSCEPTIBILITY EVALUATION REPORT APPENDIX C: LINE SUSCEPTIBILITY EVALUATION REPORT APPENDIX D: REVISION HISTORY ATTACHMENT A: INDUSTRY FAC EXPERIENCE TABLE ATTACHMENT B: REFERENCED CORRESPONDENCE AND COMMUNICATIONS Report No. 0700.104-02, Revision 2 Page 1 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

1. Introduction Flow-Accelerated Corrosion (FAC) is a form of material degradation that results in thinning of the inside pipe wall in carbon steel piping and fittings under certain flow and chemistry conditions. If undetected, FAC may result in piping rupture and subsequent fatalities, injuries, equipment damage, unplanned plant shutdown, and transients that pose undesirable challenges to plant operators. Consequently, all US nuclear plants, including Indian Point, have FAC programs in place to detect and mitigate FAC before piping failure in accordance with Generic Letter 89-08 [7.1].

An effective FAC program includes three key elements: the System Susceptibility Evaluation (SSE), which defines and controls the program scope; the CHECWORKS computer model, which predicts wear rates for every modeled component; and the Susceptible Non-Modeled (SNM) Program, which prioritizes non-modeled but susceptible lines according to FAC potential.

Report No. 0700.104-02, Revision 2 Page 2 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

2. Purpose This document contains the development and results of an FAC System Susceptibility Evaluation (SSE) for Indian Point Energy Center Unit 2. Each plant system, subsystem, and line is classified as either susceptible or non-susceptible to FAC. Susceptible piping forms the scope of the Indian Point FAC program, while non-susceptible piping is excluded from the FAC program. Susceptible piping is further categorized as either modelable in the EPRI computer program CHECWORKS Steam/Feedwater Application (SFA) or non-modelable. Susceptible Non-Modeled (SNM) piping falls outside the capabilities of CHECWORKS SFA.

The purpose of this document is to:

  • Define the scope of the Flow-Accelerated Corrosion (FAC) program.
  • Identify all plant lines to be modeled in the EPRI computer program CHECWORKS Steam/Feedwater Application (SFA).
  • Identify all plant lines that form the scope of the Susceptible Non-Modeled (SNM) program.

Report No. 0700.104-02, Revision 2 Page 3 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

3. Scope The scope of this System Susceptibility Evaluation is all plant piping. This includes piping in all systems, subsystems, and lines. This document reflects the current operating status of the plant. Periodic review and update of this document is recommended by EPRIS Recommendations for an Effective Flow-Accelerated Corrosion Program, NSAC 202L [7.2].

Section 4 of this document contains a record of all assumptions made. Section 5 describes the methodology employed in this analysis. The results obtained are documented in Section 6 and in the Appendices. Finally, Section 7 includes a list of all references used in this analysis.

Report No. 0700.104-02, Revision 2 Page 4 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

4. Assumptions 4.1. General Assumptions The following assumptions apply to all plant systems, subsystems, or lines.

4.1.1. Piping with nominal pipe size less than or equal to 2 is assumed to be socket welded. Likewise, lines over 2 in diameter are assumed butt-welded.

4.1.2. If piping material is unknown, carbon steel material is assumed.

4.1.3. If a portion of a system, subsystem, or line is susceptible, then the entire system, subsystem, or line is considered susceptible. An exception is made for lines where valves are the only susceptible components. Since valves are inspected by the Preventative Maintenance or Corrective Action programs, they are considered outside the FAC program.

4.1.4. Lines on the Indian Point P&IDs [7.3] containing normally closed valves are assumed to operate less than 2% of the time. Likewise, lines containing valves that are normally open are assumed to operate greater than 2% of the time. This assumption is used when specific valve information is not found in the System Descriptions [7.4], Plant Operating Manuals [7.5], or responses to questions by Indian Point personnel [7.6].

4.1.5. It is assumed that no normally closed valves leak, unless confirmed otherwise by plant operating history.

4.1.6. Lines that exist in non-susceptible systems or subsystems are excluded from further analysis on the system or subsystem level, respectively.

These lines may or may not appear in the Appendices.

4.2. System, Subsystem, and Line Specific Assumptions Assumptions and susceptibility decisions made specifically for a single system, subsystem, or line appear in the Comments field of the Susceptibility Evaluation reports in the Appendices.

4.2.1. Instrumentation, level control lines, and indicator lines are assumed to have insufficient flow to be susceptible to FAC.

4.2.2. Floor drains, miscellaneous capped drain and vent lines, and miscellaneous vent lines to the atmosphere are assumed to have insufficient flow to be susceptible to FAC (or operate infrequently).

4.2.3. Multiple line names are used for the same line in cases where susceptibility changed along the line and in cases where relationships to CHECWORKS are simplified by separating sections of lines.

Report No. 0700.104-02, Revision 2 Page 5 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE) 4.2.4. The supply and return headers for multiple unit heaters, lines 2-UH-003 and 2-UH-071, are continued on a drawing that could not be located by Indian Point personnel. The continuations of these lines, as well as any lines fed by these headers should be considered FAC-susceptible until proven otherwise.

4.2.5. It is assumed that Boiler Feed Pump seal water lines from the Condensate system do not increase to above 200ºF when passing through the Boiler Feed Pumps.

4.2.6. Judging by the flow configuration on drawing A209775 [7.3], the header containing steam from several unit heaters (24UHR, 211UHR, 219UHR, 221UHR), steam traps (UHT-2-2, UHT-4-1), and the oil preheater does not appear to have an outlet. If an outlet exists that is not shown on the drawing, it should be assumed susceptible to FAC until proven otherwise through further evaluation.

4.2.7. Judging by the flow configuration on drawing B193201 [7.3], lines 2-UH-002 and 2-UH-079 appear to have no inlet. If an inlet exists that is not shown on the drawing, it should be assumed susceptible to FAC until proven otherwise by further evaluation.

Report No. 0700.104-02, Revision 2 Page 6 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

5. Methodology The methodology employed in this analysis consisted of a number of successive steps.

Each step is explained in detail in the following sections. A flowchart of the methodology used is included in the Figure 5.1 Each plant system, subsystem, and line was reviewed against FAC susceptibility criteria and CHECWORKS modelability criteria (as defined in Section 5.1 and Section 5.2) to determine its susceptibility category. If an entire system or subsystem was determined to be non-susceptible, a line-by-line review was not conducted; however, where that was not the case, each line was evaluated and categorized accordingly and individually.

Figure 5.1 Susceptibility Evaluation Methodology All Plant Systems Determine Meets System Excluded Subsystem No Susceptibility Yes No further Susceptibility Exclusion Criteria evaluation Meets Subsystem Excluded Determine Line No Susceptibility Yes No further Susceptibility Exclusion Criteria evaluation Meets Line Excluded Susceptibility Exclusion Yes No further Criteria evaluation No CHECWORKS Can be Modeled in Yes No SNM Program Modeled CHECWORKS Report No. 0700.104-02, Revision 2 Page 7 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE) 5.1. Susceptibility Exclusion Criteria The criteria used to determine susceptibility to FAC was taken from Section 4.2 of EPRI NSAC 202L [7.2]. Systems, subsystems, and/or lines are not considered susceptible to FAC if one or more of the conditions discussed below apply.

5.1.1. FAC Resistant Material Stainless steel or low-alloy steel with chromium content equal or greater than 1.25% are FAC-resistant [7.2 and 7.7]. Lines or systems made, or replaced with, such materials are not sufficiently susceptible to FAC to warrant further analysis. It should be noted, however, that resistance to FAC does not ensure against other corrosion mechanisms such as cavitation or impingement. Therefore, even if components are replaced with FAC-resistant material, the root cause of wear should be determined before excluding the replaced components from the inspection program.

Wholesale replacement of a line with FAC resistant material would cause that line to be excluded from the FAC program. However, if one component on a line is susceptible, then the whole line was considered susceptible.

Piping material was obtained from the Piping Specifications [7.8], P&IDs

[7.3], or the Indian Point isometric drawings [7.9].

5.1.2. Superheated Steam Piping transporting superheated steam with no moisture content was classified as non-susceptible. According to EPRIs Recommendations for an Effective Flow-Accelerated Corrosion Program, FAC is known to occur only under flowing water or wet steam conditions, and has not been documented in superheated steam piping [7.2].

Steam quality was obtained from the PEPSE Model [7.10] first, followed by the operating conditions found in the Piping Specification [7.8].

5.1.3. Single-Phase Piping at Low Temperature Piping with single-phase flow and an operating temperature below 200oF does not experience FAC and was classified as non-susceptible. No temperature exclusion exists for two-phase lines [7.2]. Other degradation mechanisms, such as cavitation, may occur at low temperatures but such mechanisms are outside the scope of this analysis.

Operating temperature was obtained from the PEPSE Model [7.10] first, followed by the operating conditions found in the Piping Specification

[7.8].

5.1.4. Low Operating Frequency Piping that operates less than 2% of the plant operating time was deemed non-susceptible. In general, such piping does not experience the amount of flow required to make FAC a legitimate concern and is excluded from further analysis in favor of piping with greater FAC susceptibility. Piping Report No. 0700.104-02, Revision 2 Page 8 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE) in this category includes lines with normally closed valves and those feeding or emerging from equipment that operate less than 2% of the plant operating time.

Exceptions to this rule are made when the operating frequency may be low, but the service is especially severe [7.2].

All lines excluded due to infrequent operation would be susceptible to FAC if operating frequency is increased above the 2% threshold.

Therefore, if operating frequency is increased, these lines should be reviewed for inclusion in the FAC Program.

Operating frequency was determined by information from Plant Operating Manuals [7.5], by information found in the System Descriptions [7.4],

responses to questions by Indian Point personnel [7.6], and by valve position on the P&IDs [7.3]. See Assumption 4.1.3 for more details.

5.1.5. Combination Single-Phase Piping with Low Temperature and Operating Frequency This category is a derivative of the two previous susceptibility criteria described in Sections 5.1.3 and 5.1.4. It may be used for a system, subsystem, or a line that operates >2% of total plant operating time but only occasionally (<2% of the time) will the temperature of the single-phase fluid, within the piping, exceed 200oF. Thus, piping containing a single-phase flow that operates less than 2% of the time above 200oF was classified as non-susceptible to FAC.

5.1.6. Non-Water/Steam Piping Piping that transports fluids other than water or steam, such as air or oil, are not susceptible to FAC.

5.1.7. Dissolved Oxygen Concentration Lines containing water with high levels of dissolved oxygen (typically greater than 1000 ppb) are considered immune to FAC and can be excluded from further analysis [7.2]. Systems normally meeting this criterion include Service Water, Circulating Water, and Fire Protection.

5.1.8. Low or No Flow While instrumentation and/or sensing lines may operate continuously, they experience very limited fluid flow. Such piping does not experience the amount of flow required to make FAC a legitimate concern and is excluded from further analysis in favor of piping with greater FAC susceptibility.

5.1.9. Non-Piping Systems that do not contain piping (e.g. computer system) were excluded from the FAC program.

Report No. 0700.104-02, Revision 2 Page 9 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE) 5.1.10. Piping Removed from Service Piping that has been removed from service and capped was excluded from the FAC program. Degradation mechanisms may occur in such piping, but for Flow-Accelerated Corrosion to occur, flow is required [7.2].

Table 5.1 provides a summary of the FAC susceptibility exclusion parameters discussed in this section. Also provided is the abbreviation used for each criterion.

Table 5.1 Susceptibility Exclusion Criteria Abbreviation Reason Description EM Material Excluded due to FAC-resistant Material Excluded due to high steam Quality EQ Superheated (superheated steam)

Single Phase, ET Excluded due to Temperature T<200°F Excluded due to Infrequent operation (note:

EI Time <2% would be FAC susceptible if operated at a higher frequency)

Excluded due to a Combination of Single Phase, EC infrequent operation above temperature T>200°F for time<2%

threshold EW Non-water/steam Excluded due to no Water or steam present Excluded due to dissolved O2 content >1000 EO High D.O.

ppb EF Low or No Flow Excluded due to Low or No Flow Excluded due to no Piping components EP Non-Piping present Excluded due to Removal of piping from ER Pipe Removed service Report No. 0700.104-02, Revision 2 Page 10 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE) 5.2. Susceptible Non-Modeled (SNM) Criteria Each line that was not excluded due to criteria listed in Table 5.1 was determined to be susceptible to FAC. An explicit determination of suitability for CHECWORKS modeling was made for these lines. For each line that is susceptible but unsuitable for modeling, the basis for that determination was recorded. Lines were determined to be non-modelable in CHECWORKS if one or more of the conditions discussed below apply.

5.2.1. Weld Type Lines with socket-welded fittings were classified as non-modelable.

Almost all small bore lines (less than or equal to 2 in diameter) are constructed using socket-welded fittings. The socket weld uses a fit-up gap of variable size. This gap can greatly impact turbulence in piping, which in turn has a significant impact on wear rate. Since the size of the fit-up gap is unknown, CHECWORKS cannot accurately predict wear for socket-welded components [7.11].

For this analysis, all small bore lines were considered socket-welded and therefore non-modelable (see 4.1.1). In addition, the extremely large linear footage of small-bore lines and the often unknown thermodynamic conditions combine to make detailed modeling of small-bore piping inefficient and sometimes inaccurate.

5.2.2. Unknown Operating Conditions In cases where operating conditions cannot be accurately obtained or calculated, accurate modeling cannot be performed. In addition to chemistry, CHECWORKS requires a value for flow, frequency of operation, and two thermodynamic values (pressure, temperature, quality, or enthalpy) to predict wear. The PEPSE Model was the primary source of flow and thermodynamic conditions [7.10]. Thermodynamic conditions were also obtained from the operating conditions found in the Piping Specification [7.8]. Operating frequency was determined by valve position in the Plant Operating Manuals [7.5], on the P&IDs [7.3], from information found in System Descriptions [7.4], and through responses to questions by Indian Point personnel [7.6].

Where operating conditions were unknown or varied, the lines were classified as SNM.

5.2.3. Conditions outside CHECWORKS Modeling Capabilities Lines that operate with conditions outside of CHECWORKS modeling capabilities were considered SNM. For example, lines with entrained moisture or vent lines containing non-condensable gases were classified as non-modelable.

Report No. 0700.104-02, Revision 2 Page 11 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE) 5.2.4. Visually Inspected Lines Lines that are visually inspected during outages do not require modeling.

For many plants, this criterion applies to the Turbine crossunder piping.

5.2.5. Localized FAC Susceptibility Lines that were classified as FAC susceptible only at a single location were deemed non-modelable. Examples include carbon steel nozzles and valves in a low alloy line.

5.2.6. High Steam Quality Lines that contain very high quality (but not superheated) steam were classified as SNM. Modeling such lines is of little value as CHECWORKS predictions would be trivial.

Steam quality was primarily obtained from the PEPSE model [7.10],

followed by the operating conditions found in the Pipe Class Specifications [7.8].

Table 5.2 provides a summary of the CHECWORKS model exclusion parameters discussed in this section. Also provided is the abbreviation used for each criterion.

Table 5.2 CHECWORKS Model Exclusion Criteria Abbreviation Reason Description NS Socket-welded Non-modeled due to Socket-welds Non-modeled due to unknown or varying NC Unknown conditions operating Conditions Conditions outside Non-modeled due to conditions outside NM CHECWORKS CHECWORKS Modeling capabilities modeling capabilities NV Visual inspections Non-modeled due to Visual inspections Non-modeled due to Localized FAC NL Localized FAC susceptibility Non-modeled due to high steam Quality NQ High Steam Quality resulting in CHECWORKS predictions of little value Report No. 0700.104-02, Revision 2 Page 12 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

6. Results The following sections contain a description of the data found in the appendices.

6.1. System Susceptibility Evaluation The results of the System Susceptibility Evaluation appear in Appendix A. The report in this appendix lists all plant systems and classifies each as susceptible or non-susceptible to FAC. For those deemed non-susceptible, the reason for exclusion from the FAC program is provided. The following fields appear in this report.

6.1.1. System Code This field contains the common two-letter designation for the system.

6.1.2. System Name This field contains a brief description or name of the system.

6.1.3. Susceptible?

This field states if the system is FAC susceptible.

6.1.4. Exclusion Criteria (Excl. Crit.)

This field contains the reason the system is non-susceptible to FAC (see Table 5.1), if applicable.

6.1.5. Comments Pertinent information about the system appears in this field.

6.1.6. Reference References used in determining susceptibility appear in this field.

6.2. Subsystem Susceptibility Evaluation Susceptible systems were divided into subsystems by grouping lines of similar function. The results of the Subsystem Susceptibility Evaluation appear in Appendix B. Only subsystems from susceptible systems were analyzed. The reports in these appendices classify each subsystem as susceptible or non-susceptible to FAC. For those deemed non-susceptible, the reason for exclusion from the FAC program is provided. The following fields appear in this report.

6.2.1. Subsystem Number This field contains the number of the subsystem, where a subsystem is a subset of the system piping with similar operating parameters. Subsystem names were created for this evaluation and include the unit number, common system designation and a sequential number in the following format.

Report No. 0700.104-02, Revision 2 Page 13 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

A-BBBB-CC A Unit Number BBBB System Abbreviation CC Sequential Number Example: 2-BFD-01, 2-3EX-02 6.2.2. Subsystem Name This field contains the name of the subsystem preceded by the system (represented by the system code) that it falls into.

6.2.3. Subsystem Boundary A description of the lines that are grouped in this subsystem is shown here.

6.2.4. Flow Diagram (P&ID)

This field lists the flow diagram(s) on which the subsystem is found.

6.2.5. FAC Susceptible? (FAC. Sus.?)

This field states if the subsystem is FAC susceptible.

6.2.6. Exclusion Criteria (Excl. Crit.)

This field contains the reason the subsystem is non-susceptible to FAC (see Table 5.1), if applicable.

6.2.7. Comments Pertinent information about the subsystem appears in this field.

6.2.8. Reference References used in determining susceptibility appear in this field.

6.3. Line Susceptibility Evaluation Lines in FAC susceptible systems were placed into one of three categories:

  • Excluded lines (non-susceptible)
  • Susceptible lines to be modeled in CHECWORKS
  • Susceptible non-modeled (SNM) lines Appendix C contains the results of the line susceptibility evaluation for Indian Point Energy Center Unit 2. Appendix C is organized into sections with Section A listing CHECWORKS modeled lines, Section B listing SNM program lines, and Section C listing excluded lines. For SNM lines, the reason for exclusion from the CHECWORKS model is provided. For excluded lines, the reason for exclusion from the FAC program is provided. Not every line in a non-susceptible subsystem was explicitly analyzed and therefore only selected lines will appear in the report (see Section 4.1.6).

The following fields appear in this report.

Report No. 0700.104-02, Revision 2 Page 14 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE) 6.3.1. Line Number Indian Point does not maintain a complete piping line list. Therefore, line names needed to be created. The majority of main piping lines, depending on susceptibility, were assigned a unique Line Number. The naming convention follows a format which includes unit number, system abbreviation, a sequential number, and, if necessary, a section designator used either for parts of the same line with different susceptibility characteristics or specifications or for preventing duplicate line names:

A-BBBB-CCC-D A Unit Number BBBB System Abbreviation CCC Sequential Number D Section Designator Examples: 2-1EST-014, 2-MS-011-A 6.3.2. Size The diameter, in inches, of the majority of the line is listed here.

6.3.3. Flow Diagram This field lists the flow diagram(s) on which that the line is found.

6.3.4. Susceptibility Category (Sus. Cat.)

The susceptibility category is listed in this field. Table 6.1 defines the three susceptibility categories.

Table 6.1 Susceptibility Categories Abbreviation Category M CHECWORKS Modeled S Susceptible non-modeled (SNM)

E Excluded from the FAC program (non-susceptible) 6.3.5. Model Exclusion Criteria (Mod. Ex. Crit.)

This field appears only for SNM lines. It contains the reason each line is not modeled in CHECWORKS (see Table 5.2) when applicable.

6.3.6. Susceptibility Exclusion Criteria (FAC Ex. Crit.)

This field appears only for excluded lines. It contains the reason each line is non-susceptible to FAC (see Table 5.1) when applicable.

6.3.7. Comments Pertinent information about the line appears in this field.

Report No. 0700.104-02, Revision 2 Page 15 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE) 6.3.8. Reference References used in determining susceptibility or modelability appear in this field.

6.3.9. Line Description This field contains a description of the line.

6.4. Color-Coded Flow Diagrams Flow diagrams of all FAC susceptible systems addressed in this document are included in the Color-Coded Flow Diagrams document. The flow diagrams are color-coded based upon FAC susceptibility category and labeled to indicate line numbers. Line numbers were added to the flow diagrams. See the Color-Coded Flow Diagrams Document 0700.104-04 for the color-code convention.

6.5. Revision History Changes made for each revision of this report are documented in Appendix D.

6.6. Industry FAC Experience Table Attachment A contains a table of important industry FAC events. This table was used as an aide in determining FAC susceptibility.

6.7. FAC-Susceptible Lines Containing Orifices As a subtask of the project, a list of FAC-susceptible lines containing orifices was gathered and is shown in Table 6.2 below.

Report No. 0700.104-02, Revision 2 Page 16 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Table 6.2 FAC Susceptible Lines Containing Orifices Line Number Line Description P&ID Coord.

2-3HD-027 FWH 23A Vent to 3EX-53 A235304 H4 2-3HD-028 FWH 23A Vent to 3EX-534 A235304 H4 2-3HD-029 FWH 23B Vent to 3EX-536 A235304 H5 2-3HD-030 FWH 23B Vent to 3EX-539 A235304 H5 2-3HD-031 FWH 23C Vent to 3EX-541 A235304 H6 2-3HD-032 FWH 23C Vent to 3EX-544 A235304 H6 2-5HD-047 FWH 25A Vent 9321-F-2022 I4 2-5HD-048 FWH 25B Vent 9321-F-2022 I5 2-5HD-049 FWH 25C Vent 9321-F-2022 I6 2-AF-011-A #21 BFP discharge overflow line upstream of orifice 9321-F-2120 H3 2-AF-012-A #22 BFP discharge overflow line upstream of orifice 9321-F-2120 G3 2-AF-013-A #23 BFP discharge overflow line upstream of orifice 9321-F-2120 G3 Service Boiler Deaerator Drain to Service Boiler Feed 2-AF-043 Pumps B193201 C2 2-AF-053 AF57 Vent to Service Boiler Deaerator B193201 D2 2-AS-003 Aux. Steam from #22 LH Boiler 9321-F-2120 E5 2-AS-004 Aux. Steam from #21 RH Boiler 9321-F-2120 B5 2-AS-009 Steam to AST-26 9321-F-2120 A5 2-AS-031 Steam Header to Barge Steam Connections B192490 C4 2-AS-066 Steam to and from FP-1198 192491 G5 2-CD-025 Condensate from Header to BFP No. 21 A235307 B5 2-CD-026 Condensate from Header to BFP No. 22 A235307 E5 2-HD-001 #21 HDP to Heater Drain Pump Header 9321-F-2022 D1 2-HD-002 #22 HDP to Heater Drain Pump Header 9321-F-2022 D1 2-MS-143 Main Steam Stop Valve drain to 23 Cond. West Side A235308 D1 2-MS-144 Main Steam Stop Valve drain to 23 Cond. East Side A235308 D2 2-MSD-157 Reheater Drain Tank 21A Drain to Header 9321-F-2023 G2 2-MSD-158 Reheater Drain Tank 22A Drain to Header 9321-F-2023 E2 2-MSD-159 Reheater Drain Tank 23A Drain to Header 9321-F-2023 D2 2-MSD-166 Reheater Drain Tank 21B Drain to Header 9321-F-2023 H5 2-MSD-167 Reheater Drain Tank 22B Drain to Header 9321-F-2023 F5 2-MSD-168 Reheater Drain Tank 23B Drain to Header 9321-F-2023 D5 Report No. 0700.104-02, Revision 2 Page 17 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

7. References 7.1. Erosion/Corrosion-Induced Pipe Wall Thinning, Generic Letter 89-08, U.S.

Nuclear Regulatory Commission (NRC), May 2, 1989.

7.2. Recommendations for an Effective Flow-Accelerated Corrosion Program, EPRI NSAC 202L-R3, 1011838, May 2006.

7.3. Indian Point 2 FAC Susceptible Piping and Instrumentation Diagrams.

System (Drawing Title) P&ID # Rev #

Main Steam 9321-F-2017 84 Main Steam A235308 49 Main Steam 227780 53 Main Steam Traps (Sheet 1) 9321-F-2041 35 Main Steam Traps (Sheet 2) 9321-F-2042 21 Steam Drain and Gland Seal for Low and High Pressure Turbines B237144 4 Steam Drain and Gland Seal for Low and High Pressure Turbines B237145 6 Boiler Feed Pump Turbine Steam Lines Drains & Vents 9321-H-2024 23 Moisture Separator and Reheater Drains & Vents 9321-F-2023 35 Moisture Preseparator A228272 16 Extraction Steam 9321-F-2020 43 Extraction Steam Trap System 9321-F-2031 17 Heater Drains & Vents 9321-F-2022 53 Heater Drains & Vents A235304 23 Moisture Separator Reheaters Vent Chamber Discharge A209847 13 Superheater Building Service Boilers 9321-F-2120 69 Auxiliary Steam Supply and Condensate Return System A209775 45 Auxiliary Steam System (Sheet 1) B192490 22 Auxiliary Steam System (Sheet 2) 192491 39 Auxiliary Steam System (Sheet 3) B192493 8 Water Treatment System (Sheet 3) A192496 18 Steam Activated Carbon Filter B227209 16 Auxiliary Boiler Feed B193201 15 Condensate & Boiler Feed Pump Suction (Sheet 1) 9321-2018 141 Condensate & Boiler Feed Pump Suction (Sheet 2) A235307 32 Boiler Feedwater 9321-F-2019 113 Steam Generator Blowdown & Blowdown Sample System 9321-F-2729 69 7.4. Indian Point System Descriptions/Design Manuals.

System Name SD No.

Main and Reheat Steam Supply 18.00 Extraction Steam and Heater Drains and Vents 19.02 Condensate 20.00 Feedwater 21.00 Circulating Water 23.04 Service Water 24.00 Report No. 0700.104-02, Revision 2 Page 18 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System Name SD No.

Main Turbine Lube Oil 26.00 Auxiliary Steam 29.01 Instrument Air 29.02 7.5. Indian Point Plant Operating Manuals Operating Manual Doc. No Rev.

Auxiliary Steam 2-SOP-29-01 19 House Service Boilers 2-SOP-29-01-01 17 House Service Boilers Fuel Oil 2-SOP-29-01-02 18 House Service Boilers Feedwater 2-SOP-29-01-03 14 7.6. Electronic correspondence between CSI and Indian Point personnel (see Attachment B).

7.6.1. Email from Ryan Doremus (CSI) to Ian Mew (IPEC) regarding a Line Naming Convention, dated 7/27/2009.

7.6.2. Email from Ian Mew (IPEC) to Ryan Doremus (CSI) regarding responses to information requests, dated 8/10/2009.

7.6.3. Email from Ian Mew (IPEC) to Ryan Doremus (CSI) regarding responses to information requests, dated 8/13/2009.

7.7. EPRI, Flow-Accelerated Corrosion in Power Plants, B. Chexal et al, EPRI TR-106611-R1, 1998.

7.8. Entergy Nuclear Northeast Indian Point Energy Center - Unit No. 2:

Specification For Fabrication of Piping Systems Turbine Generator Plant; Specification No. 9321-01-248-18; Revision 18; January 15, 2010.

7.9. Indian Point Isometric Drawings for FAC-susceptible piping, gathered by CSI on 4/3/2009.

7.10. Indian Point Uprate PEPSE Model with New HP Turbine High Pressure Turbine Expansion, Run Date 10/26/06.

7.11. CHECWORKS Steam/Feedwater Application Guidelines for Plant Modeling and Evaluation of Component Inspection Data. EPRI, Palo Alto, CA and CSI Technologies, Inc., Elgin, IL: 2009. 1019176.

7.12. Flow Accelerated Corrosion Program Plan Supplement; Edited by Hazel Pearsall, FAC Program Engineer; Dated April 28, 2003 (For information only).

7.13. Indian Point FAC Program History Outage Reports, transmitted to CSI on 7/15/2009 (For information only).

7.14. CHUG Industry Experience Documents (see Attachment A) (For information only).

7.15. Indian Point System List. Transmitted to CSI on 1/6/2010 (For information only).

Report No. 0700.104-02, Revision 2 Page 19 of 19

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Appendix A System Susceptibility Evaluation Report Report No. 0700.104-02, Appendix A, Revision 2 Page A-1 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

AF Auxiliary Feedwater Yes This system delivers feedwater to the Service P&ID Boilers Text19:

AS Auxiliary Steam Yes This system generates and distributes steam to SD No. 29.01 the various auxiliaries requiring steam for operation.

Text19:

AST Auxiliary Steam Traps Yes This system includes all steam trap lines for the SD No. 29.01 Auxiliary Steam System Text19:

BD Steam Generator Blowdown Yes This system takes water from the steam P&ID generators for maintaining proper Steam Generator Chemistry.

Text19:

CD Condensate Pump Discharge Yes This system includes piping from some high SD No. 20.0 temperature Feedwater Heaters.

Text19:

EST Extraction Steam Traps Yes This system includes all steam trap lines SD No. 19.02 originating from extraction steam, heater drains, heater vents, and moisture separator drains.

Text19:

EX Extraction Steam Yes This system includes extraction steam to the SD No. 19.02 Feedwater Heaters Text19:

FW Main Feed Water Yes This system supplies feedwater to the steam SD No. 21.0 generators.

Text19:

GS Gland Sealing Steam Yes This system supplies sealing steam to the HP, P&IDs LP, and BFP Turbines.

Text19:

GST Gland Steam Traps Yes This system includes all steam trap lines for the P&ID Gland Steam System Text19:

HD Heater Drains & Vents Yes This system includes Feedwater Heater Drains SD No. 19.02 and Vents, and piping from the Heater Drain Pumps to the Boiler Feed Pump suction.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-2 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

MS Main Steam Yes This system supplies steam to the HP and BFP SD No. 18.0 Turbines and the MSRs.

Text19:

MSD Moisture Separator Reheater Drains Yes This system includes MSR Drains to the Heater P&ID Drain Tank, No. 25 Feedwater Heaters, and the Drains Collecting Tank Text19:

MST Main Steam Traps Yes This system includes all steam trap lines for the SD No. 18.0 Main Steam System Text19:

PD Moisture Preseparator Drains Yes This system removes moisture from piping P&ID upstream of the HP Turbine Crossunder Piping.

Text19:

RST Reheat Steam Traps Yes This system includes all steam trap lines from SD No. 18.0 the Reheater Steam system.

Text19:

SB Service Boiler Yes This system contains some steam piping from P&ID the Service Boiler.

Text19:

UH Condensate Return Unit Heaters to Yes This system contains condensate from the Pipe Spec Service Boiler D condensate return unit heaters to the service boiler deaerator.

Text19:

UHT Condensate Return Unit Heater Yes This system includes all steam trap lines for the P&ID Steam Traps Condensate Return Unit Heaters to Service Boiler Deaerator system.

Text19:

VCD MSR Vent Chamber Discharge Yes This system contains steam from the MSRs. P&ID Text19:

A 4160 VAC No EP This is an electrical system that does not contain piping.

Text19:

AAC AAC EDG Controls & Excitation No EP This system does not contain piping.

Text19:

AAC Alternate AC Diesel Generator No EP This system contains only the generator and not the associated piping.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-3 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

AB Auxiliary Building No EP This system includes the building and not the associated piping.

Text19:

ABS Auxiliary Building Sump No ET This system handles low temperature water from floor drains.

Text19:

ABV Auxiliary Building Ventilations No EW This system vents non-condensable gases.

Text19:

AC Chill Water System No ET This system operates at under 200 degF Text19:

ACW Auxiliary Cooling Water No ET This system operates at under 200 degF P&ID Text19:

ADM Admin Building No EP This system includes the building and not the associated piping.

Text19:

ARMS Area Radiation Monitoring Systems No EP This system does not contain piping.

Text19:

B 480 VAC No EP This is an electrical system that does not contain piping.

Text19:

BA Breathing Air No EW This system does not contain water or steam.

Text19:

BMS Boron Management No EW This system does not contain water or steam.

Text19:

BS Containment (Building) Spray No EI Containment spray only operates in emergency SD No. 10.2 situations.

Text19:

CA Secondary Chemical Addition No EW This system does not contain water or steam.

Text19:

CCW Component Cooling Water System No ET This system provides low-temperature water to P&ID various equipment in the plant.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-4 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

CEDM Control Element Drive Mechanism No EP This system does not contain piping.

Control Text19:

CF Chemical Feed No EW This system does not contain water or steam. P&IDs Text19:

CL Chlorination No EW This system does not contain water or steam. P&ID Text19:

COMM Communications No EP This system does not contain piping.

Text19:

CP Cathodic Protection No EP This is an electrical system that does not contain piping.

Text19:

CPC Core Protection Calculators No EP This system does not contain piping.

Text19:

CPV Penetration Room Ventilation No EW This system vents non-condensable gases.

Text19:

CRDX Cardox (CO2 Fire Protection No EW This system does not contain water or steam. P&ID System)

Text19:

CRV Control Room Ventilation No EW This system vents non-condensable gases.

Text19:

CS Condensate Pump Suction No ET This system transports low-temperature water SD No. 20.0 from the Condensers to the Condensate Pump.

Text19:

CT Condensate Storage & Transfer No ET Condensate transfer is a low-temperature SD No. 20.0 system used to ensure there is no raw water contamination of the condensate.

Text19:

CV Condenser Air Vents No EW This system does not contain water or steam.

Text19:

CVCS Chemical and Volume Control No EM This system is comprised entirely of FAC- P&IDs System resistant piping.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-5 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

CVH Containment Vent Header No EW This system vents non-condensable gases.

Text19:

CW Circulating Water No EO This system provides river water to cool the SD No. 23.0 steam in the condensers.

Text19:

D 125 VDC No EP This is an electrical system that does not contain piping.

Text19:

DA Diesel Generator Starting Air No EW This system does not contain water or steam. P&ID Text19:

DCH Drain Collection Header No EF Flow in this system is too low to facilitate FAC.

Text19:

DF Diesel Generator Fuel Oil No EW This system does not contain water or steam. P&ID Text19:

DFAS Diverse Emergency Feed Actuation No EP This system does not contain piping.

Text19:

DSS Diverse Scram System No EP This system does not contain piping.

Text19:

DW Domestic Water No EO This system contains highly oxygenated water from the city supply.

Text19:

EC Plant Computer No EP This system does not contain piping.

Text19:

EDG Emergency Diesel Generator No EP This system does not contain piping.

Text19:

EDG EDG Controls & Excitation No EP This system does not contain piping.

Text19:

EFW Emergency Feed Water No EI This system only operates in emergency situations.

Text19:

EHC Electro-Hydraulic (Mechanical) No EP This system does not contain piping.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-6 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

EHC MFP EHC Controls No EP This system does not contain piping.

Text19:

EHC MTG EHC Controls No EP This system does not contain piping.

Text19:

EL Emergency Lighting (Safe No EP This system does not contain piping.

Shutdown)

Text19:

EOF Emergency Operations Facility No EP This system does not contain piping.

Text19:

ES ESFAS No EP This system does not contain piping.

Text19:

EXCT Main Generator Excitation & No EP This system does not contain piping.

Protection Text19:

F Switchyard No EP This system does not contain piping.

Text19:

FD Fire Detection No EP This system does not contain piping.

Text19:

FHS Fuel Handling System No EW This system does not contain water or steam.

Text19:

FO Diesel Fuel Oil Storage and No EW This system does not contain water or steam. P&ID Transfer Text19:

FP Spent Fuel Pool Cooling No ET This system operates at under 200 degF Text19:

FS Fire Protection (Water) No ET This system uses low-temperature city water. P&IDs Text19:

FWCS Feed Water Control System No EF This system contains low-flow instrumentation lines.

Text19:

GCH Gas Collection Header No EW This system does not contain water or steam.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-7 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

GG Generator Gas No EW This system does not contain water or steam.

Text19:

GSO Hydrogen Seal Oil (Mechanical) No EW This system does not contain water or steam.

Text19:

GZ Gaseous Radwaste No EW This system does not contain water or steam.

Text19:

H 6900 VAC No EP This is an electrical system that does not contain piping.

Text19:

H2 Hydrogen No EW This system does not contain water or steam.

Text19:

HAL Halon No EW This system does not contain water or steam.

Text19:

HPA Hydrogen Purge System No EW This system does not contain water or steam.

Text19:

HPSI High Pressure Safety Injection No EM Lines in this system are composed of FAC- Pipe Spec resistant material.

Text19:

HR H2 Recombiners No EW This system does not contain water or steam.

Text19:

HS Generator Hydrogen Supply No EW This system provides hydrogen to the steam P&ID generators.

Text19:

HT Heat Tracking No EP This system does not contain piping.

Text19:

IA Instrument Air No EW This system does not contain water or steam. SD No. 29.02 Text19:

IB Isophase Bus No EP This system does not contain piping.

Text19:

IBC Isophase Bus Cooling No ET This system operates at under 200 degF Report No. 0700.104-02, Appendix A, Revision 2 Page A-8 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

IC Incore Instrumentation No EF This system contains low-flow instrumentation lines.

Text19:

ICC Reactor Vessel Level Monitoring & No EF This system contains low-flow instrumentation CETs lines.

Text19:

IS Intake Structure No EO This system contains highly oxygenated water.

Text19:

JW Diesel Generator Jacket Water No EO This system is fed with raw water. P&ID Text19:

K Annunciators No EP This system does not contain piping.

Text19:

LA 120/208 VAC Misc. Lighting & No EP This is an electrical system that does not Power Dist. contain piping.

Text19:

LLRW Low Level Radwaste Bldg No EP This system does not contain piping.

Text19:

LO Main Turbine Lube Oil No EW This system does not contain water or steam. P&ID Text19:

LPSI Low Pressure Safety Injection No EM Lines in this system are composed of FAC- Pipe Spec resistant material.

Text19:

LRBV Low Level Radwaste Building No EW This system vents non-condensable gases.

Ventilation Text19:

LRW Liq Radwaste Mgmt No EW This system does not contain water or steam.

Text19:

MET Meteorological Instrumentation No EP This system does not contain piping.

Text19:

MW City Water Make-Up No EO This system contains highly oxygenated water P&ID from the city supply.

Text19:

N2 Nitrogen No EW This system does not contain water or steam. P&ID Report No. 0700.104-02, Appendix A, Revision 2 Page A-9 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

NI Nuclear Instrumentation No EP This system does not contain piping.

Text19:

NT Neutralizing System No EP This system does not contain piping.

Text19:

PA Reactor Building Purge Air No EW This system does not contain water or steam.

Text19:

PASS Post Accident Sampling No EI This system only operates in post-accident conditions Text19:

PCA Penetration Cooling Air No EW This system does not contain water or steam. P&ID Text19:

PH Plant Heating No EW This system does not contain water or steam.

Text19:

PMU Makeup Demineralizer System No ET This system operates at under 200 degF Text19:

PPS Plant Protection System No EP This system does not contain piping.

Text19:

PS Primary Sampling No EI This system operates less than 2% of plant operation Text19:

PW Primary Water No ET This system contains low-temperature water P&ID Text19:

RB Reactor Building No EP This system does not contain piping.

Text19:

RBHV Reactor Building Ventilation No EW This system vents non-condensable gases.

Text19:

RCP Reactor Coolant Pumps No EP This system does not contain piping.

Text19:

RCS Reactor Coolant System No EM All lines in the RCS system are composed of P&ID FAC-resistant piping Report No. 0700.104-02, Appendix A, Revision 2 Page A-10 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

RDAC/S RDAC (Radiation Dose No EP This system does not contain piping.

PING Assessment Computer)/SPING (S Text19:

RHR Residual Heat Removal System No EM All lines in the RHR system are stainless steel. Pipe Spec Text19:

RMS Radiation Monitoring No EP This system does not contain piping.

Text19:

RPS Reactor Protection System No EP This system does not contain piping.

Text19:

RRS Reactor Regulating System No EP This system does not contain piping.

Text19:

RS Reheat Steam No EQ Reheater Steam provides superheated steam to SD No. 18.0 the LP and BFP Turbines.

Text19:

RT Resin Transfer No EW This system does not contain water or steam.

Text19:

RWB Radwaste Building No EP This system does not contain piping.

Text19:

RX Reactor Core No EP This system does not contain piping.

Text19:

RZ Regen Waste No EP This system does not contain piping.

Text19:

SA Service Air No EW This system does not contain water or steam. P&ID Text19:

SDBC Steam Dump Bypass Control No EP This system does not contain piping.

System Text19:

SDC Shutdown Cooling No EI This system only operates during shutdown.

Text19:

SEC Security No EP This system does not contain piping.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-11 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

SFP Spent Fuel Pit No ET The water in this system is low-temperature.

Text19:

SGS Stm. Gen. Secondary No EP This system does not contain piping.

Text19:

SI Safety Injection System No EM This system is comprised entirely of FAC- P&ID resistant piping.

Text19:

SMS Seismic Monitoring System No EP This system does not contain piping.

Text19:

SP Sample System No EM Sample piping at IPEC is stainless steel. Pipe Spec Text19:

SPDS Safety Parameter Display System No EP This system does not contain piping.

Text19:

SS Secondary Sampling No EM Sample piping at IPEC is stainless steel. Pipe Spec Text19:

STP Sewage Treatment Plant No EP This system does not contain piping.

Text19:

SW Service Water No EO Service Water has a high concentration of P&ID dissolved oxygen.

Text19:

SWC Stator Water Cooling No ET This system operates at under 200 degF Text19:

SZ Solid Waste Management No EW This system does not contain water or steam.

Text19:

TB Turbine Building No EP This system does not contain piping.

Text19:

TBS Turbine Building Sump No EF Flow in this system is too low to facilitate FAC.

Text19:

TBV Turbine Building Ventilation No EW This system vents non-condensable gases.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-12 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Text19:

TG Main Turbine & Generator No EP This system does not contain piping.

Text19:

TG MTG & MFPT Supervisory No EP This system does not contain piping.

Instrumentation Text19:

TS Traveling Screens No EP This system does not contain piping.

Text19:

VENT Miscellaneous Ventilation System No EW This system vents non-condensable gases.

Text19:

VLPM U2 Vibration & Loose Parts No EP This system does not contain piping.

Monitoring System Text19:

VS Condenser Vacuum No EW This system vents non-condensable gases.

Text19:

XFMR Main, Auxiliary & Startup No EP This system does not contain piping.

Transformers Text19:

Y Inverters & Vital 120 VAC No EP This is an electrical system that does not contain piping.

Report No. 0700.104-02, Appendix A, Revision 2 Page A-13 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

System System Code System Name Number Susceptible? Excl. Crit. Comments Reference Exclusion Criteria Legend:

EC Excluded due to Combination of infrequent op above temp threshold EF Excluded due to low or no Flow EI Excluded due to Infrequent operation EM Excluded due to FAC-resistant Material EO Excluded due to high dissolved Oxygen content EP Exluded, does not contain Piping EQ Excluded due to high steam Quality ER Excluded, Removed from service and "cut" and "capped" ET Excluded due to operating Temperature (single phase, < 200 deg F)

EW Excluded because system, subsytem, or line is non-Water Report No. 0700.104-02, Appendix A, Revision 2 Page A-14 of 14

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Appendix B Subsystem Susceptibility Evaluation Report Indian Point Unit 2 Report No. 0700.104-02, Appendix B, Revision 2 Page B-1 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Feedwater (AF), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-AF-01 Text19: Service Boiler 9321-F-2120, Yes P&ID Auxiliary Feedwater B193201 Lines 2-AF-02 Text19: Aux Feedwater to and 9321-F-2120 No EI Valves to coolers shown closed on P&ID P&ID from Sample Coolers Report No. 0700.104-02, Appendix B, Revision 2 Page B-2 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam (AS), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-AS-01 Text19: Auxiliary Steam to 9321-F-2120 No EQ Atomizing steam is superheated SD No. 29.01 Burner Atomizing Steam 2-AS-02 Text19: Auxiliary Steam to B192493 No ER Source line shown capped on P&ID P&ID Fuel Oil Suction Heaters 2-AS-03 Text19: Remainder of 9321-F-2120, Yes SD No. 29.01 Auxiliary Steam A209775, B192490, B192491, B192493, B192496, B193201, B227209 Report No. 0700.104-02, Appendix B, Revision 2 Page B-3 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam Traps (AST), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-AST-01 Text19: Steam Trap Lines 9321-F-2120, Yes P&ID from Auxiliary Steam B192490, Lines B192491 Report No. 0700.104-02, Appendix B, Revision 2 Page B-4 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Steam Generator Blowdown (BD), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-BD-01 Text19: Steam Generator 9321-F-2729 Yes SD No. 18.0 Blowdown to Sample Coolers and Blowdown Tank Report No. 0700.104-02, Appendix B, Revision 2 Page B-5 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Pump Discharge (CD), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-CD-01 Text19: Condensate Lines 9321-2018, No ET Condensate is below 200 degF before PEPSE Between Condensate A235307 passing through the #22 FWHs Pumps and #22 Feedwater Heaters 2-CD-02 Text19: Condensate Lines 9321-2018, Yes PEPSE Downstream of #22 A235307 Feedwater Heaters Report No. 0700.104-02, Appendix B, Revision 2 Page B-6 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam Traps (EST), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-1EST-01 Text19: Extraction Steam Trap 9321-F-2031 Yes P&ID Headers to the Drains Collecting Tank 2-3EST-01 Text19: Steam Trap lines from 9321-F-2031 Yes P&ID Extraction Steam to the #23 FWHs 2-4EST-01 Text19: Lines from Stm Traps 9321-F-2031 Yes P&IDs to the Stm Trap Drains Header from Ext lines to #24 FWHs 2-4EST-02 Text19: Lines upstream of the 9321-F-2031 No EQ Lines upstream of the steam traps are PEPSE Stm Traps from #24 superheated.

FWH's Ext Stm Header 2-5EST-01 Text19: Steam Trap lines from 9321-F-2031 Yes P&ID Extraction Steam to the #25 FWHs 2-6EST-01 Text19: Steam Trap lines from 9321-F-2031 Yes P&ID Extraction Steam to the #26 FWHs Report No. 0700.104-02, Appendix B, Revision 2 Page B-7 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-1EX-01 Text19: LP Turb Ext Stm to 9321-F-2020 Yes PEPSE

  1. 21 FWHs Text19:

2-2EX-01 LP Turbine Extraction 9321-F-2020 Yes PEPSE Steam to #22 Feedwater Heaters 2-3EX-01 Text19: Boiler Feed Pump A227780 Yes PEPSE Turbine Drains to Condensers 2-3EX-02 Text19: LP Turbine Extraction 9321-F-2020, Yes PEPSE Steam to #23 9321-F-2031 Feedwater Heaters 2-4EX-01 Text19: Extraction Steam 9321-F-2020, No EQ Steam is superheated upstream of the P&IDs Lines to #24 9321-F-2031 steam traps.

Feedwater Heaters 2-5EX-01 Text19: HP Turbine A235308 Yes P&IDs Crossunder Piping Drip Pots to the Condenser Text19:

2-5EX-02 Small Bore Steam A235308 No EI Control valves in these lines are normally SD No. 18.0 Drains to the closed.

Condenser via FCV-1156, 1157, 1164, 1165, and 1166.

2-5EX-03 Text19: Extraction Steam from 9321-F-2020, Yes PEPSE Separating Tanks to 9321-F-2031

  1. 25 Feedwater Heaters 2-6EX-01 Text19: HP Turbine Extraction 9321-F-2020 Yes PEPSE Steam to #26 Feedwater Heaters Report No. 0700.104-02, Appendix B, Revision 2 Page B-8 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Feed Water (FW), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-FW-01 Text19: Feedwater Lines from 9321-F-2019 Yes PEPSE the Boiler Feed Pumps to the Steam Generators 2-FW-02 Text19: Auxiliary Feedwater 9321-F-2019 No EI Auxiliary Feedwater only operates during SD No. 21.0 Lines to Steam startup, shutdown, and emergency Generator conditions.

2-FW-03 Text19: Boiler Feed Pump 9321-F-2019 Yes SD No. 21.0 Recirc Lines to the Drains Collecting Tank Report No. 0700.104-02, Appendix B, Revision 2 Page B-9 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Gland Sealing Steam (GS), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-GS-01 Text19: Gland Steam to and A235308, Yes P&IDs from HP, LP, and BFP B237144, Turbines B237145, 9321-H-2024 Report No. 0700.104-02, Appendix B, Revision 2 Page B-10 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Gland Steam Traps (GST), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-GST-01 Text19: Steam Trap Lines 9321-H-2024 Yes P&ID from the Gland Seal System Report No. 0700.104-02, Appendix B, Revision 2 Page B-11 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-1HD-01 Text19: #21 Feedwater Heater A235304 Yes PEPSE Drain Lines Text19:

2-1HD-02 #21 Feedwater Heater A235304 Yes P&ID Vents Text19:

2-2HD-01 #22 Feedwater Heater A235304 Yes PEPSE Drain Lines Text19:

2-2HD-02 #22 Feedwater Heater A235304 Yes P&ID Vents Text19:

2-3HD-01 #23 Feedwater Heater A235304 Yes PEPSE Drain Lines Text19:

2-3HD-02 #23 Feedwater Heater A235304 Yes P&ID Vents Text19:

2-4HD-01 #24 Feedwater Heater A235304 Yes PEPSE Drain Lines Text19:

2-4HD-02 #24 Feedwater Heater A235304 Yes P&ID Vents Text19:

2-5HD-01 Heater Drains from 9321-F-2022 Yes PEPSE

  1. 25 Feedwater Heaters 2-5HD-02 Text19: Heater Vents from 9321-F-2022, Yes P&ID
  1. 25 Feedwater Heater A235304 and Heater Drain Tank vents to #25 Feedwater Heaters 2-5HD-03 Text19: HDT Drains to HDPs 9321-F-2022, Yes PEPSE and Condensers and A235304 HDP Vents to HDT Report No. 0700.104-02, Appendix B, Revision 2 Page B-12 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-6HD-01 Text19: Heater Drains from 9321-F-2022 Yes PEPSE

  1. 26 Feedwater Heaters 2-6HD-02 Text19: Heater Vents from 9321-F-2022, Yes P&ID
  1. 26 Feedwater Heater A235304 2-HD-01 Text19: Heater Drain Pump 9321-F-2022 Yes PEPSE discharge to Boiler Feed Pumps Report No. 0700.104-02, Appendix B, Revision 2 Page B-13 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-MS-01 Text19: Main Steam from Stm 9321-F-2017, Yes P&IDs Gen to HP Turbine, A227780, BFP Turbine, MSRs, A235308 Aux. Steam, SJAEs, and Priming Ejectors.

2-MS-02 Text19: Main Steam to MSR A227780 No EI These lines operate during startup and SD No. 18.0 Header Dumps to shutdown.

Condenser 2-MS-03 Text19: Small Bore Turbine A235308 No EI Control valves in these lines are normally SD No. 18.0 Steam Drains to the closed.

Condenser via FCV-1154, 1155, 1158, and 1159 2-MS-04 Text19: H.P. Cylinder Steam A235308 No EI Control valves in line are closed during SD No. 18.0 Heating and Seals normal operation.

Text19:

2-MS-05 Scavenging Steam 9321-F-2023 No ER Piping is abandoned in place. P&ID from 6th Stage Extraction Steam 2-MS-06 Text19: Main Steam Supply to A235308 Yes P&ID Gland Steam Header Text19:

2-MS-07 HP Turbine A235308, Yes PEPSE Crossunder Piping to A227780 the Moisture Separators Report No. 0700.104-02, Appendix B, Revision 2 Page B-14 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-MSD-01 Text19: Moisture Separator 9321-F-2023 Yes PEPSE Drains to the Heater Drain Tank and Drains Collecting Tank 2-MSD-02 Text19: Reheater Drains to 9321-F-2023 Yes PEPSE

  1. 26 Feedwater Heaters and Condensers Report No. 0700.104-02, Appendix B, Revision 2 Page B-15 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-MST-01 Text19: Steam Trap Lines 9321-F-2041, Yes P&ID from the Main Steam 9321-F-2042 System Report No. 0700.104-02, Appendix B, Revision 2 Page B-16 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Preseparator Drains (PD), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-PD-01 Text19: Moisture Preseparator A228272 Yes PEPSE Drain Lines Report No. 0700.104-02, Appendix B, Revision 2 Page B-17 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Reheat Steam Traps (RST), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-RST-01 Text19: Reheat Steam Trap 9321-H-2024 Yes P&IDs Lines Downstream of Reheater Steam Traps 2-RST-02 Text19: All other Reheater A227780, 9321- No EQ Reheat Steam upstream of the steam traps PEPSE Steam Trap Lines H-2024 is superheated.

Report No. 0700.104-02, Appendix B, Revision 2 Page B-18 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Service Boiler (SB), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-SB-01 Text19: Service Boiler Lines 9321-F-2120, Yes SD No. 29.01 A227780, A209775, B193201 Report No. 0700.104-02, Appendix B, Revision 2 Page B-19 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-UH-01 Text19: Condensate Return 9321-F-2120, Yes P&IDs from Unit Heaters to A209775, the Deaerator B192491, B193201 Report No. 0700.104-02, Appendix B, Revision 2 Page B-20 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Return Unit Heater Steam Traps (UHT), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-UHT-01 Text19: Steam Trap Lines A209775 Yes P&ID from the Condensate Return from Unit Heaters to the Deaerator system Report No. 0700.104-02, Appendix B, Revision 2 Page B-21 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

MSR Vent Chamber Discharge (VCD), Unit 2 Subsystem FAC Excl.

Number Subsystem Name Subsystem Boundary P&ID No. Sus? Crit. Comments Reference 2-VCD-01 Text19: Moisture Separator A209847 Yes PEPSE Reheater Vent Chamber Discharge Lines Exclusion Criteria (Excl. Crit.) Legend:

EC Excluded due to Combination of infrequent op above temp threshold EF Excluded due to low or no Flow EI Excluded due to Infrequent operation EM Excluded due to FAC-resistant Material EO Excluded due to high dissolved Oxygen content EP Exluded, does not contain Piping EQ Excluded due to high steam Quality ER Excluded, Removed from service and "cut" and "capped" ET Excluded due to operating Temperature (single phase, < 200 deg F)

EW Excluded because system, subsytem, or line is non-Water Report No. 0700.104-02, Appendix B, Revision 2 Page B-22 of 22

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Appendix C Line Susceptibility Evaluation Report Indian Point Unit 2 Report No. 0700.104-02, Appendix C, Revision 2 Page C-1 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Feedwater (AF), Unit 2 Section B: SNM Program Lines 2-AF-01: Service Boiler Auxiliary Feedwater Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AF-001 6 9321-F-2120 S NC Operating conditions unknown. P&ID Deaerator Header to Boiler Feed Pumps 2-AF-002 Text19: 4 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Feed header to #23 Boiler Feed Pump and #10 House Service Deaerator 2-AF-003 Text19: 4 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Feed header to #21 Boiler Feed Pump 2-AF-004 Text19: 4 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Feed header to #22 Boiler Feed Pump 2-AF-005 Text19: 4 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Feed header to #23 Boiler Feed Pump 2-AF-006 Text19: 6 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Feed header to #10 House Service Deaerator 2-AF-007 Text19: 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID Boiler Feed Pump overflow header to Deaerator 2-AF-008 Text19: 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID Boiler Feed Pump discharge Unit #3 tie-in.

2-AF-011-A Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID #21 BFP discharge overflow line upstream of orifice 2-AF-011-B Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID #21 BFP discharge overflow line downstream of orifice 2-AF-012-A Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID #22 BFP discharge overflow line upstream of orifice 2-AF-012-B Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID #22 BFP discharge overflow line downstream of orifice 2-AF-013-A Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID #23 BFP discharge overflow line upstream of orifice Report No. 0700.104-02, Appendix C, Revision 2 Page C-2 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Feedwater (AF), Unit 2 Section B: SNM Program Lines 2-AF-01: Service Boiler Auxiliary Feedwater Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AF-013-B 1 9321-F-2120 S NS Operating conditions unknown. P&ID #23 BFP discharge overflow line downstream of orifice 2-AF-014 Text19: 3 9321-F-2120 S NC Operating conditions unknown. P&ID #21 BFP discharge line Text19:

2-AF-015 3 9321-F-2120 S NC Operating conditions unknown. P&ID #22 BFP discharge line Text19:

2-AF-016 3 9321-F-2120 S NC Operating conditions unknown. P&ID #23 BFP discharge line Text19:

2-AF-017 4 9321-F-2120 S NC Operating conditions unknown. P&ID #21 and #22 BFP discharge header Text19:

2-AF-018 2.5 9321-F-2120 S NC Operating conditions unknown. P&ID LH Boiler #22 Feed Line Text19:

2-AF-019 2.5 9321-F-2120 S NC Operating conditions unknown. P&ID AF-144 bypass line Text19:

2-AF-020 4 B193201, 9321-F-2021 S NC Operating conditions unknown. P&ID Unit 1 Service Boiler Feed Pump discharge tie-in line.

2-AF-021 Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID BFP discharge header to Desuperheater Station 2-AF-022 Text19: 2.5 9321-F-2120 S NC Operating conditions unknown. P&ID RH Boiler #21 Feed Line Text19:

2-AF-023 2.5 9321-F-2120 S NC Operating conditions unknown. P&ID AF-138 bypass line Text19:

2-AF-024 0.75 9321-F-2120 S NS Operating conditions unknown. P&ID RH Boiler #21 Continuous Blowdown Line 2-AF-025 Text19: 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID RH Boiler #21 Intermittent Blowdown Line 2-AF-026 Text19: 0.75 9321-F-2120 S NS Operating conditions unknown. P&ID LH Boiler #22 Continuous Blowdown Line 2-AF-027 Text19: 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID LH Boiler #22 Intermittent Blowdown Line 2-AF-028 Text19: 0.75 9321-F-2120 S NS Operating conditions unknown. P&ID Continuous Blowdown line to HSBSPCLs Report No. 0700.104-02, Appendix C, Revision 2 Page C-3 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Feedwater (AF), Unit 2 Section B: SNM Program Lines 2-AF-01: Service Boiler Auxiliary Feedwater Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AF-029 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID Boiler Blowdown Tank Bottom Drain Text19:

2-AF-030 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID Boiler Blowdown Tank Drain Bypass Text19:

2-AF-031 1.25 9321-F-2120 S NS Operating conditions unknown. P&ID Boiler Blowdown Tank Drain Vent Text19:

2-AF-032 6 9321-F-2120 S NC Operating conditions unknown. P&ID Boiler Blowdown Tank Drain 2-AF-033 Text19: B193201, 9321-F-2120 S NS Operating conditions unknown. P&ID ABSPCLB Aux. Feed Inlet Text19:

2-AF-034 9321-F-2120 S NS Operating conditions unknown. P&ID ABSPCLB Aux. Feed Outlet to Dissolved O2 Analyzer 2-AF-035 Text19: 9321-F-2120 S NS Operating conditions unknown. P&ID ABSPCLB Aux. Feed Outlet to Cooling Bath 2-AF-037 Text19: 2 B193201 S NC Operating conditions unknown. P&ID Flash Tank Drain to Service Boiler Deaerator 2-AF-038 Text19: 1.25 B193201 S NS Operating conditions unknown. P&ID Service Boiler Deaerator Vent Text19:

2-AF-039 6 B193201 S NC Operating conditions unknown. P&ID Service Boiler Deaerator 6" Drain to OB 2-AF-040 Text19: 4 B193201 S NC Operating conditions unknown. P&ID Service Boiler Deaerator Drain vent Text19:

2-AF-041 2 B193201 S NS Operating conditions unknown. P&ID Service Boiler Deaerator 2" Drain to OB 2-AF-042 Text19: 0.75 B193201 S NS Operating conditions unknown. P&ID Drain from multiport valve.

Text19:

2-AF-043 6 B193201 S NC Operating conditions unknown. P&ID Service Boiler Deaerator Drain to Service Boiler Feed Pumps 2-AF-044 Text19: 4 B193201 S NC Operating conditions unknown. P&ID Service Boiler Pump No. 11 Feed Line 2-AF-045 Text19: 4 B193201 S NC Operating conditions unknown. P&ID Service Boiler Pump No. 12 Feed Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-4 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Feedwater (AF), Unit 2 Section B: SNM Program Lines 2-AF-01: Service Boiler Auxiliary Feedwater Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AF-046 4 B193201 S NC Operating conditions unknown. P&ID Service Boiler Pump No. 13 Feed Line 2-AF-047 Text19: 3 B193201 S NC Operating conditions unknown. P&ID Service Boiler Pump No. 11 Discharge Line 2-AF-048 Text19: 3 B193201 S NC Operating conditions unknown. P&ID Service Boiler Pump No. 12 Discharge Line 2-AF-049 Text19: 3 B193201 S NC Operating conditions unknown. P&ID Service Boiler Pump No. 13 Discharge Line 2-AF-050 Text19: 6 B193201 S NC Operating conditions unknown. P&ID Service Boiler Pump Discharge Header 2-AF-051 Text19: 1.5 B193201 S NS Operating conditions unknown. P&ID AF59 Vent to Service Boiler Deaerator 2-AF-052 Text19: 1.5 B193201 S NS Operating conditions unknown. P&ID AF58 Vent to Service Boiler Deaerator 2-AF-053 Text19: 1.5 B193201 S NS Operating conditions unknown. P&ID AF57 Vent to Service Boiler Deaerator 2-AF-054 Text19: 1.5 B193201 S NS Operating conditions unknown. P&ID Check valve vent header to Service Boiler Deaerator 2-AF-057 Text19: 9321-F-2120 S NS Operating conditions unknown. P&ID Chemical Bench Sink Section C: Excluded Lines 2-AF-01: Service Boiler Auxiliary Feedwater Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AF-009 1.5 9321-F-2120 E EI Valve shown closed on P&ID. P&ID Boiler Feed Pump Bypass line to #22 BFP overflow line Report No. 0700.104-02, Appendix C, Revision 2 Page C-5 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Feedwater (AF), Unit 2 Section C: Excluded Lines 2-AF-01: Service Boiler Auxiliary Feedwater Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AF-010 1 9321-F-2120 E EI Valve shown closed on P&ID. P&ID Boiler Feed Pump Bypass line to #23 BFP overflow line 2-AF-036 Text19: 9321-F-2120 E ET Low Temperature discharge from Cooling P&ID Cooling Bath Drain Bath 2-AF-055 Text19: 2 B193201 E ER #20 HSB Removed from Service SD No. 29.01 Line from #20 House Service Boiler to Service Boiler Deaerator 2-AF-056 Text19: 2.5 B193201 E ER Piping retired in place P&ID Line to AF92 Report No. 0700.104-02, Appendix C, Revision 2 Page C-6 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam (AS), Unit 2 Section B: SNM Program Lines 2-AS-03: Remainder of Auxiliary Steam Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AS-001-A 10 B192493, B192490, S NC Operating conditions unknown. P&ID 10" Aux. Steam Header 192491 2-AS-002 Text19: 10 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Steam Header from Service Boilers 2-AS-003 Text19: 8 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Steam from #22 LH Boiler Text19:

2-AS-004 8 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Steam from #21 RH Boiler Text19:

2-AS-005 4 9321-F-2120 S NC Operating conditions unknown. P&ID Aux. Steam Drain to Deaerator Text19:

2-AS-006 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID FCV-1148 Bypass Line Text19:

2-AS-008 1.25 A209775 S NS Operating conditions unknown. P&ID Steam to 21 and 22 Air Tempering Units 2-AS-009 Text19: 8 9321-F-2120 S NC Operating conditions unknown. P&ID Steam to AST-26 Text19:

2-AS-015 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID #21 RH Boiler Drain Text19:

2-AS-016 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID #22 LH Boiler Drain Text19:

2-AS-017 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID Boiler Drain Header to Blowdown Tank 2-AS-018 Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID RH Boiler #21 Atomizing Steam bleed-off line 2-AS-019 Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID LH Boiler #22 Atomizing Steam bleed-off line 2-AS-025 Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID Oil Separator Tank outlet Text19:

2-AS-026 1 9321-F-2120 S NS Operating conditions unknown. P&ID Oil Separator Tank outlet to Carbon Filter Tank 2-AS-027 Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID Oil Separator Tank outlet to Floor Drain Report No. 0700.104-02, Appendix C, Revision 2 Page C-7 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam (AS), Unit 2 Section B: SNM Program Lines 2-AS-03: Remainder of Auxiliary Steam Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AS-030 2 B192490 S NS Operating conditions unknown. P&ID Steam to Water Heater Text19:

2-AS-031 6 B192490 S NC Operating conditions unknown. P&ID Steam Header to Barge Steam Connections 2-AS-032 Text19: 4 B192490 S NC Operating conditions unknown. P&ID Steam to AS845 Text19:

2-AS-033 1.5 B192490 S NS Operating conditions unknown. P&ID Steam to AS840 Text19:

2-AS-036 4 B192490 S NC Operating conditions unknown. P&ID Steam line to UH-1239 Text19:

2-AS-037 1 B192490 S NS Operating conditions unknown. P&ID PRV-7343 Bypass Text19:

2-AS-039 B192490 S NS Operating conditions unknown. P&ID Steam to Screens Text19:

2-AS-046 4 192491 S NC Operating conditions unknown. P&ID Steam header to Service Boiler Feed Pump No. 13 2-AS-047 Text19: 6 192491 S NC Operating conditions unknown. P&ID Steam header to Carbon Filter Tanks Text19:

2-AS-048 2 192491 S NS Operating conditions unknown. P&ID Steam to Service Boiler Phosphate Mix Tanks and Continuous Heaters 2-AS-051 Text19: 2 192491 S NS Operating conditions unknown. P&ID Steam to Service Boiler Feed Pump No. 13 2-AS-053 Text19: 4 192491 S NC Operating conditions unknown. P&ID Steam from Service Boiler Feed Pump No. 13 2-AS-054 Text19: 8 192491 S NC Operating conditions unknown. P&ID Steam from Service Boiler Feed Pump No. 13 to #10 Service Deaerator 2-AS-055 Text19: 8 192491 S NC Operating conditions unknown. P&ID Steam from Service Boiler Feed Pump No. 13 to Atmospheric Vent header 2-AS-057 Text19: 10 192491 S NC Operating conditions unknown. P&ID Steam drain to #10 Service Deaerator via AS484 Report No. 0700.104-02, Appendix C, Revision 2 Page C-8 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam (AS), Unit 2 Section B: SNM Program Lines 2-AS-03: Remainder of Auxiliary Steam Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AS-058 4 192491 S NC Operating conditions unknown. P&ID Steam to Heating and Ventilation Pressure Reducing Station 2-AS-060 Text19: 2 192491 S NS Operating conditions unknown. P&ID Steam from Heating and Ventilation Pressure Reducing Station 2-AS-070 Text19: 3 192491, B227209 S NC Operating conditions unknown. P&ID Steam header to Carbon Filter Tanks Text19:

2-AS-073 2 192491 S NS Operating conditions unknown. P&ID Header to Service Boiler Phosphate Mix Tanks 2-AS-074 Text19: 0.75 192491 S NS Operating conditions unknown. P&ID Steam to Service Boiler Phosphate Mix Tank No. 11 2-AS-075 Text19: 0.75 192491 S NS Operating conditions unknown. P&ID Steam to Service Boiler Phosphate Mix Tank No. 12 2-AS-076 Text19: 2 192491 S NS Operating conditions unknown. P&ID Steam to Continuous Heaters via AS568 2-AS-077 Text19: 2 192491 S NS Operating conditions unknown. P&ID Steam to Continuous Heaters via AS112 2-AS-079 Text19: 2 192491 S NS Operating conditions unknown. P&ID Steam header to Continuous Heaters via AS568 2-AS-080 Text19: 1 192491 S NS Operating conditions unknown. P&ID Steam to Continuous Heater No. 11 Text19:

2-AS-081 1 192491 S NS Operating conditions unknown. P&ID Steam to Continuous Heater No. 12 Text19:

2-AS-082-A 8 192491 S NC Operating conditions unknown. P&ID Floor trench drain to cap Text19:

2-AS-082-B 1.5 192491 S NS Operating conditions unknown. P&ID Floor trench drain downstream of cap Text19:

2-AS-083 16 192491 S NC Operating conditions unknown. P&ID Aux Steam Vent to Atmosphere Text19:

2-AS-087 3 B227209 S NC Operating conditions unknown. P&ID Steam to 21ACFT Text19:

2-AS-088 3 B227209 S NC Operating conditions unknown. P&ID Steam to 22ACFT Report No. 0700.104-02, Appendix C, Revision 2 Page C-9 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam (AS), Unit 2 Section B: SNM Program Lines 2-AS-03: Remainder of Auxiliary Steam Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AS-091 0.75 B227209 S NS Operating conditions unknown. P&ID Port Basin drain from Aux. Steam supply to ACFTs 2-AS-093 Text19: 1.5 B227209 S NS Operating conditions unknown. P&ID PRV-5245 Bypass Text19:

2-AS-096 4 192491, B193201 S NC Operating conditions unknown. P&ID Aux. Steam to Flash Tank Section C: Excluded Lines 2-AS-03: Remainder of Auxiliary Steam Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AS-001-B 10 B192493, 141718 E ER Line capped. P&ID 10" Aux. Steam Header Text19:

2-AS-013 0.75 9321-F-2120 E EI Valve shown closed on P&ID. P&ID #21 RH Boiler Relief Valve Drain Text19:

2-AS-014 0.75 9321-F-2120 E EI Valve shown closed on P&ID. P&ID #22 LH Boiler Relief Valve Drain Text19:

2-AS-020 1 9321-F-2120 E EQ Superheated Steam from steam drum SD No. 29.01 Aux. Steam to Fuel Oil Heaters Text19:

2-AS-026-A 1 9321-F-2120 E EI Valve shown closed on P&ID P&ID Oil Separator Tank outlet line between floor drain line and Carbon Filter Tank Line 2-AS-028 Text19: 1 9321-F-2120 E EI Valve shown closed on P&ID. P&ID Oil Separator Tank outlet line between floor drain line and Carbon Filter Tank Line 2-AS-029 Text19: 2.5 9321-F-2120 E EI Soot Blowers are used infrequently SD No. 29.01 LH Boiler #22 Soot Blower Line Text19:

2-AS-040 6 B192490 E EI Valve shown closed on P&ID. P&ID Barge Steam connections header Text19:

2-AS-045 2 B192490 E ER Downstream equipment retired in place. P&ID Line to House Service Fuel Oil Heaters 2-AS-056 Text19: 3 192491 E EI Relief valve normally closed P&ID AS527 Bypass Relief Valve Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-10 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam (AS), Unit 2 Section C: Excluded Lines 2-AS-03: Remainder of Auxiliary Steam Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AS-059 2.5 192491 E EI Valve shown closed on P&ID. P&ID AS484 Bypass Line Text19:

2-AS-071 3 B227209, 192491 E EI Relief valve normally closed P&ID Relief line from Steam header to Carbon Filter Tanks 2-AS-072 Text19: 10 192491 E EI Valve normally closed. Engineer Judgement; Vent from Steam header to #10 Service Deaerator 2-AS-078 Text19: 0.75 192491 E EI Valve shown closed on P&ID. P&ID AS112 Bypass and Bypass Drain Text19:

2-AS-084 6 192491 E ER Turbine retired in place. P&ID Motor Gen. Unit No. 13 Turbine Drain line to Atmos. Vent 2-AS-086 Text19: 6 B192490, B192493 E ER Equipment retired in place P&ID Aux. Steam to Steam Tracing in Fuel Oil Pump House 2-AS-094 Text19: 4 B227209 E EI Valve normally closed. P&ID 21ACFT Aux. Steam Supply floor trench drain 2-AS-095 Text19: 4 B227209 E EI Valve shown closed on P&ID. P&ID 22ACFT Aux. Steam Supply floor trench drain Report No. 0700.104-02, Appendix C, Revision 2 Page C-11 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam Traps (AST), Unit 2 Section B: SNM Program Lines 2-AST-01: Steam Trap Lines from Auxiliary Steam Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AST-002 0.75 A227780, A209775 S NS Operating conditions unknown. P&ID Steam to and from AST-50 Text19:

2-AST-006 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID Steam to Hot Water Heat Exchangers Text19:

2-AST-007 0.75 9321-F-2120 S NS Operating conditions unknown. P&ID Steam to and from AS-1176 Text19:

2-AST-007-A 1 9321-F-2120 S NS Operating conditions unknown. P&ID Steam to Condensate Return via AST-35 2-AST-009 Text19: 2 9321-F-2120 S NS Operating conditions unknown. P&ID Hot Water Heat Exchangers Discharge Line 2-AST-010 Text19: 4 9321-F-2120 S NC Operating conditions unknown. P&ID Condensate Return Header Text19:

2-AST-011 0.75 9321-F-2120 S NS Operating conditions unknown. P&ID Steam to and from AS-1093 Text19:

2-AST-013 9321-F-2120 S NS Operating conditions unknown. P&ID Steam Supply Drain to Condensate Return via AST-31 2-AST-017 Text19: 8 A209775 S NC Operating conditions unknown. P&ID Steam to AST-33 Text19:

2-AST-019 1 A209775 S NS Operating conditions unknown. P&ID AST-33 Discharge Text19:

2-AST-020 1 A209775 S NS Operating conditions unknown. P&ID Steam to AST-20 Text19:

2-AST-021 1 9321-F-2120 S NS Operating conditions unknown. P&ID #21 Fuel Oil Heater heating steam outlet 2-AST-021-A Text19: 1 A209775 S NS Operating conditions unknown. P&ID AST-20 Discharge Text19:

2-AST-022 1 9321-F-2120 S NS Operating conditions unknown. P&ID #22 Fuel Oil Heater heating steam outlet 2-AST-023 Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID #23 Fuel Oil Heater heating steam outlet 2-AST-024 Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID Fuel Oil heating steam outlet from steam traps to oil separator tank 2-AST-025 Text19: 4 A209775 S NC Operating conditions unknown. P&ID Steam to AST-2 and 3 Report No. 0700.104-02, Appendix C, Revision 2 Page C-12 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam Traps (AST), Unit 2 Section B: SNM Program Lines 2-AST-01: Steam Trap Lines from Auxiliary Steam Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AST-027 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to AST-6 Text19:

2-AST-028 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to AST-7 Text19:

2-AST-032 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to AST-4 Text19:

2-AST-033 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to AST-5 2-AST-034 Text19: 0.75 B192490 S NS Operating conditions unknown. P&ID Steam to and from AS849 Text19:

2-AST-035-A 0.75 A209775 S NS Operating conditions unknown. P&ID AST-6 Discharge Text19:

2-AST-036 0.75 A209775 S NS Operating conditions unknown. P&ID AST-7 Discharge Text19:

2-AST-037 1.5 A209775 S NS Operating conditions unknown. P&ID AST-4 Discharge Text19:

2-AST-038 0.75 B192490 S NS Operating conditions unknown. P&ID Steam to and from UH-1238 Text19:

2-AST-038-A 0.75 A209775 S NS Operating conditions unknown. P&ID AST-5 Discharge Text19:

2-AST-041 1 B192490 S NS Operating conditions unknown. P&ID Steam to and from AST-27 Text19:

2-AST-042 1 B192490 S NS Operating conditions unknown. P&ID AST-27 Bypass Text19:

2-AST-043 1 B192490 S NS Operating conditions unknown. P&ID Steam to and from AST-42 Text19:

2-AST-044 1 B192490 S NS Operating conditions unknown. P&ID AST-42 Bypass Text19:

2-AST-049-A 0.5 192491 S NS Operating conditions unknown. P&ID Steam to and from AST-38 Text19:

2-AST-050-A 0.5 192491 S NS Operating conditions unknown. P&ID Steam to and from AST-37 Text19:

2-AST-052 0.75 192491 S NS Operating conditions unknown. P&ID Steam to and from AST-45 Text19:

2-AST-058 1 A209775 S NS Operating conditions unknown. P&ID AST-2 Discharge Text19:

2-AST-059 1 A209775 S NS Operating conditions unknown. P&ID AST-3 Discharge Text19:

2-AST-061 1 192491 S NS Operating conditions unknown. P&ID Steam to and from AST-39 Report No. 0700.104-02, Appendix C, Revision 2 Page C-13 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam Traps (AST), Unit 2 Section B: SNM Program Lines 2-AST-01: Steam Trap Lines from Auxiliary Steam Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AST-063 1 192491 S NS Operating conditions unknown. P&ID Steam to and from AST-32 Text19:

2-AST-065 1 192491 S NS Operating conditions unknown. P&ID AST-32 and 39 drain to Cond. Return Header 2-AST-066 Text19: 2 192491 S NS Operating conditions unknown. P&ID Steam to and from FP-1198 Text19:

2-AST-067 2 192491 S NS Operating conditions unknown. P&ID Steam to and from UH-1300 Text19:

2-AST-069-A 3 192491 S NC Operating conditions unknown. P&ID Stub to AST-30 and drain Text19:

2-AST-069-B 1 192491 S NS Operating conditions unknown. P&ID Steam to and from AST-30 Section C: Excluded Lines 2-AST-01: Steam Trap Lines from Auxiliary Steam Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AST-003 0.75 A227780 E EI Valve shown closed on P&ID. P&ID AST-50 Bypass Line Text19:

2-AST-008 1 9321-F-2120 E EI Valve shown closed on P&ID. P&ID AST-35 Bypass Line Text19:

2-AST-012 1 9321-F-2120 E EI Valve normally closed. Engineer Judgement AST-26 Bypass Line Text19:

2-AST-014 9321-F-2120 E EI Valve shown closed on P&ID. P&ID AST-31 bypass line Text19:

2-AST-018 1 A209775 E EI Valve shown closed on P&ID. P&ID AST-33 Bypass Text19:

2-AST-035 0.75 B192490 E EI Valve shown closed on P&ID. P&ID Steam Trap Bypass Text19:

2-AST-049-B 0.5 192491 E EI Valve shown closed on P&ID. P&ID AST-38 Bypass Text19:

2-AST-050-B 0.5 192491 E EI Valve shown closed on P&ID. P&ID AST-37 Bypass Text19:

2-AST-062 192491 E EI Valve shown closed on P&ID. P&ID AST-39 Bypass Report No. 0700.104-02, Appendix C, Revision 2 Page C-14 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Auxiliary Steam Traps (AST), Unit 2 Section C: Excluded Lines 2-AST-01: Steam Trap Lines from Auxiliary Steam Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-AST-064 1 192491 E EI Valve shown closed on P&ID. P&ID AST-32 Bypass Text19:

2-AST-068 1 192491 E EI Valve shown closed on P&ID. P&ID UH-1301 Bypass Line Text19:

2-AST-069-C 1 192491 E EI Valve shown closed on P&ID. P&ID AST-30 Bypass Text19:

2-AST-069-D 0.75 192491 E EF Low flow to floor drain P&ID Stub drain 2-AST-085 Text19: 0.75 192491 E ER Turbine retired in place. P&ID Motor Gen. Unit No. 13 Turbine Drain line to and from steam trap Report No. 0700.104-02, Appendix C, Revision 2 Page C-15 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Steam Generator Blowdown (BD), Unit 2 Section B: SNM Program Lines 2-BD-01: Steam Generator Blowdown to Sample Coolers and Blowdown Tank Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-BD-001 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 21 Blowdown via MS-67-A Text19:

2-BD-002 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 21 Blowdown via MS-67-B Text19:

2-BD-003 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 22 Blowdown via MS-67-C Text19:

2-BD-004 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 22 Blowdown via MS-67-D 2-BD-005 Text19: 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 23 Blowdown via MS-67-E Text19:

2-BD-006 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 23 Blowdown via MS-67-F Text19:

2-BD-007 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 24 Blowdown via MS-67-G Text19:

2-BD-008 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 24 Blowdown via MS-67-H Text19:

2-BD-009-A 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 21 Blowdown Upstream of Line Spec Change 2-BD-010-A Text19: 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 22 Blowdown Upstream of Line Spec Change 2-BD-011-A Text19: 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 23 Blowdown Upstream of Line Spec Change 2-BD-012-A Text19: 2 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 24 Blowdown Upstream of Line Spec Change 2-BD-017 Text19: 1 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 23 1" Blowdown Line Text19:

2-BD-018 1 9321-F-2729 S NS Small bore piping with unknown conditions. P&ID SG 24 1" Blowdown Line Text19:

2-BD-019 18 9321-F-2729 S NC Operating conditions unknown. P&ID Blowdown Tank vent to Atmosphere Report No. 0700.104-02, Appendix C, Revision 2 Page C-16 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Steam Generator Blowdown (BD), Unit 2 Section C: Excluded Lines 2-BD-01: Steam Generator Blowdown to Sample Coolers and Blowdown Tank Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-BD-009-B 2 9321-F-2729 E EM Stainless Steel Piping Pipe Spec SG 21 Blowdown Downstream of Line Spec Change 2-BD-010-B Text19: 2 9321-F-2729 E EM Stainless Steel Piping Pipe Spec SG 22 Blowdown Downstream of Line Spec Change 2-BD-011-B Text19: 2 9321-F-2729 E EM Stainless Steel Piping Pipe Spec SG 23 Blowdown Downstream of Line Spec Change 2-BD-012-B Text19: 2 9321-F-2729 E EM Stainless Steel Piping Pipe Spec SG 24 Blowdown Downstream of Line Spec Change 2-BD-013 Text19: 0.75 9321-F-2729 E EM Sample lines are SS CSI Document No. SG 21 Blowdown to Sample Cooler 0700.104.C.010 2-BD-014 Text19: 0.75 9321-F-2729 E EM Sample lines are SS CSI Document No. SG 22 Blowdown to Sample Cooler 0700.104.C.010 2-BD-015 Text19: 0.75 9321-F-2729 E EM Sample lines are SS CSI Document No. SG 23 Blowdown to Sample Cooler 0700.104.C.010 2-BD-016 Text19: 0.75 9321-F-2729 E EM Sample lines are SS CSI Document No. SG 24 Blowdown to Sample Cooler 0700.104.C.010 2-BD-020 Text19: 9321-F-2729 E EM Sample lines are SS CSI Document No. Line to Sample Cooler from 0700.104.C.010 Blowdown Tank Vent via MS-1102 2-BD-021 Text19: 9321-F-2729 E EM Sample lines are SS CSI Document No. Line to Sample Cooler from 0700.104.C.010 Blowdown Tank Vent via MS-1103 2-BD-022 Text19: 9321-F-2729 E EM Sample lines are SS CSI Document No. Line to Sample Cooler from 0700.104.C.010 Blowdown Tank Vent via MS-1104 Report No. 0700.104-02, Appendix C, Revision 2 Page C-17 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Pump Discharge (CD), Unit 2 Section A: CHECWORKS Model Lines 2-CD-02: Condensate Lines Downstream of #22 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-CD-001 14 9321-2018 M PEPSE CD80A-1-FWH 22A to HEADER:

Condensate from FWH 22-A to Condensate Header 2-CD-002 Text19: 14 9321-2018 M PEPSE CD80A-2-FWH 22B to HEADER:

Condensate from FWH 22-B to Condensate Header 2-CD-003 Text19: 14 9321-2018 M PEPSE CD80A-3-FWH 22C to HEADER:

Condensate from FWH 22-C to Condensate Header 2-CD-004 Text19: 20 9321-2018 M PEPSE CD80A-4-FWH 22 OUTLET HEADER: Condensate Header from FWHs 22-A and 22-B 2-CD-005 Text19: 24 9321-2018, A235307 M PEPSE CD80A-5-FWH 22 to FWH 23 HEAD: Condensate Header to #23 FWHs Text19:

2-CD-006 24 A235307 M PEPSE CD80A-6-FWH 23 INLET HEADER:

Condensate Header to FWHs 23-A and 23-B Text19:

2-CD-007 14 A235307 M PEPSE CD80A-7-HEADER to FWH 23A:

Condensate line to FWH 23-A 2-CD-008 Text19: 14 A235307 M PEPSE CD80A-8-HEADER to FWH 23B:

Condensate line to FWH 23-B 2-CD-009 Text19: 14 A235307 M PEPSE CD80A-9-HEADER to FWH 23C:

Condensate line to FWH 23-C 2-CD-013 Text19: 14 A235307 M PEPSE CD80-1-FWH 23A to FWH 24A:

Condensate line to FWH 24-A 2-CD-014 Text19: 14 A235307 M PEPSE CD80-2-FWH 23B to FWH 24B:

Condensate line to FWH 24-B Report No. 0700.104-02, Appendix C, Revision 2 Page C-18 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Pump Discharge (CD), Unit 2 Section A: CHECWORKS Model Lines 2-CD-02: Condensate Lines Downstream of #22 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-CD-015 14 A235307 M PEPSE CD80-3-FWH 23C to FWH 24C:

Condensate line to FWH 24-C 2-CD-016 Text19: 14 A235307 M PEPSE CD81-1-FWH 24A to FWH 25A:

Condensate line to FWH 25-A 2-CD-017 Text19: 14 A235307 M PEPSE CD81-2-FWH 24B to FWH 25B:

Condensate line to FWH 25-B 2-CD-018 Text19: 14 A235307 M PEPSE CD81-3-FWH 24C to FWH 25C:

Condensate line to FWH 25-C 2-CD-019 Text19: 14 A235307 M PEPSE CD82-1-FWH 25A to HDR:

Condensate from FWH 25-A to Condensate Header 2-CD-020 Text19: 14 A235307 M PEPSE CD82-2-FWH 25B to HDR:

Condensate from FWH 25-B to Condensate Header Text19:

2-CD-021 14 A235307 M PEPSE CD82-3-FWH 25C to HDR:

Condensate from FWH 25-C to Condensate Header Text19:

2-CD-022 24 A235307 M PEPSE CD82-4-HDR 25BT to 25CT:

Condensate header from FWHs 25-A and 25-B 2-CD-023 Text19: 24 A235307 M PEPSE CD82-5-HDR 25CT to HDP OUT:

Condensate Header to BFPs Upstream of Heater Drain Pump inlet 2-CD-024 Text19: 30 A235307 M PEPSE CD83-1-HDR HDP to BFP21T:

Condensate Header to BFPs Downstream of Heater Drain Pump inlet 2-CD-025 Text19: 24 A235307 M PEPSE CD83-2-HDR to BFP21: Condensate from Header to BFP No. 21 Report No. 0700.104-02, Appendix C, Revision 2 Page C-19 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Pump Discharge (CD), Unit 2 Section A: CHECWORKS Model Lines 2-CD-02: Condensate Lines Downstream of #22 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-CD-026 24 A235307 M PEPSE CD83-3-HDR to BFP22: Condensate from Header to BFP No. 22 Section C: Excluded Lines 2-CD-02: Condensate Lines Downstream of #22 Feedwater Heaters Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-CD-010 1.5 A235307 E EI Valve shown closed on P&ID. P&ID CD-16 Bypass Line Text19:

2-CD-011 1.5 A235307 E EI Valve shown closed on P&ID. P&ID CD-16-1 Bypass Line Text19:

2-CD-012 1.5 A235307 E EI Valve shown closed on P&ID. P&ID CD-16-2 Bypass Line Text19:

2-CD-027 12 A235307 E EI Valve shown closed on P&ID. P&ID Feedwater Heater Bypass Line Text19:

2-CD-028 2 A235307 E EI Valve shown closed on P&ID. P&ID CD-21 Bypass Line Text19:

2-CD-029 2 A235307 E EI Valve shown closed on P&ID. P&ID CD-21-1 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-20 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam Traps (EST), Unit 2 Section B: SNM Program Lines 2-1EST-01: Extraction Steam Trap Headers to the Drains Collecting Tank Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-1EST-013-A 4 9321-F-2031 S NC Operating conditions unknown. P&ID Steam Trap Header from EST-1 and 1A 2-1EST-013-B Text19: 4 9321-F-2031 S NC Operating conditions unknown. P&ID Steam Trap Header from EST-1, 1A, 2, and 6 2-1EST-014 Text19: 6 9321-F-2031 S NC Operating conditions unknown. P&ID Main Extraction Steam Trap Header 2-3EST-01: Steam Trap lines from Extraction Steam to the #23 FWHs Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3EST-012-A 2 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-14 Text19:

2-3EST-012-B 2 9321-F-2031 S NS Operating conditions unknown. P&ID EST-14 to Steam Trap Header Text19:

2-3EST-013-A 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-15 Text19:

2-3EST-013-B 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID Header from EST-15 to Steam Trap Header 2-3EST-014-A Text19: 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-16 Text19:

2-3EST-014-B 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID Header from EST-16 to Steam Trap Header 2-3EST-015-A Text19: 2 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-17 Text19:

2-3EST-015-B 2 9321-F-2031 S NS Operating conditions unknown. P&ID EST-17 to Steam Trap Header Text19:

2-3EST-016-A 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-18 Text19:

2-3EST-016-B 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-18 to Steam Trap Header Text19:

2-3EST-017-A 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-19 Text19:

2-3EST-017-B 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-19 to Steam Trap Header Text19:

2-3EST-018-A 2 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-20 Report No. 0700.104-02, Appendix C, Revision 2 Page C-21 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam Traps (EST), Unit 2 Section B: SNM Program Lines 2-3EST-01: Steam Trap lines from Extraction Steam to the #23 FWHs Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3EST-018-B 2 9321-F-2031 S NS Operating conditions unknown. P&ID EST-20 to Steam Trap Header Text19:

2-3EST-019-A 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-21 Text19:

2-3EST-019-B 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-21 to Steam Trap Header Text19:

2-3EST-020-A 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID Extraction Steam to EST-23 2-3EST-020-B Text19: 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-23 to Steam Trap Header 2-4EST-01: Lines from Stm Traps to the Stm Trap Drains Header from Ext lines to #24 FWHs Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-4EST-001 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-5 to Steam Trap Header Text19:

2-4EST-002 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-6 to Steam Trap Header Text19:

2-4EST-003 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-7 to Steam Trap Header Text19:

2-4EST-004 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-8 to Steam Trap Header Text19:

2-4EST-005 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-9 to Steam Trap Header Text19:

2-4EST-006 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-10 to Steam Trap Header Text19:

2-4EST-007 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-11 to Steam Trap Header Text19:

2-4EST-008 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-12 to Steam Trap Header Text19:

2-4EST-009 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-13 to Steam Trap Header 2-5EST-01: Steam Trap lines from Extraction Steam to the #25 FWHs Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EST-040-A 0.75 9321-F-2031 S NS Flow Conditions Unknown P&ID Extraction steam to EST-4 Report No. 0700.104-02, Appendix C, Revision 2 Page C-22 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam Traps (EST), Unit 2 Section B: SNM Program Lines 2-5EST-01: Steam Trap lines from Extraction Steam to the #25 FWHs Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EST-040-B 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-4 to Steam Trap Header 2-6EST-01: Steam Trap lines from Extraction Steam to the #26 FWHs Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-6EST-015-A 2 9321-F-2031 S NS Flow Conditions Unknown P&ID Extraction Steam to EST-1 Text19:

2-6EST-015-B 2 9321-F-2031 S NS Flow Conditions Unknown P&ID Extraction Steam to EST-1A Text19:

2-6EST-015-C 2 9321-F-2031 S NS Operating conditions unknown. P&ID EST-1 to Steam Trap Header Text19:

2-6EST-015-D 2 9321-F-2031 S NS Operating conditions unknown. P&ID EST-1A to Steam Trap Header Text19:

2-6EST-016-A 0.75 9321-F-2031 S NS Flow Conditions Unknown P&ID Extraction Steam to EST-2 Text19:

2-6EST-016-B 0.75 9321-F-2031 S NS Operating conditions unknown. P&ID EST-2 to Steam Trap Header Section C: Excluded Lines 2-3EST-01: Steam Trap lines from Extraction Steam to the #23 FWHs Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3EST-012-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-14 Bypass Line Text19:

2-3EST-013-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-15 Bypass Line Text19:

2-3EST-014-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-16 Bypass Line Text19:

2-3EST-015-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-17 Bypass Line Text19:

2-3EST-016-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-18 Bypass Line Text19:

2-3EST-017-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-19 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-23 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam Traps (EST), Unit 2 Section C: Excluded Lines 2-3EST-01: Steam Trap lines from Extraction Steam to the #23 FWHs Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3EST-018-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-20 Bypass Line Text19:

2-3EST-019-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-21 Bypass Line Text19:

2-3EST-020-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-23 Bypass Line 2-5EST-01: Steam Trap lines from Extraction Steam to the #25 FWHs Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EST-040-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-4 Bypass Line 2-6EST-01: Steam Trap lines from Extraction Steam to the #26 FWHs Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-6EST-015-E 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-1 Bypass Line Text19:

2-6EST-015-F 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-1A Bypass Line Text19:

2-6EST-016-C 9321-F-2031 E EI Valve shown closed on P&ID. P&ID EST-2 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-24 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section A: CHECWORKS Model Lines 2-1EX-01: LP Turb Ext Stm to #21 FWHs Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-1EX-001 26 9321-F-2020 M PEPSE ES?-1-1STPT ES TO FWH 21A: NE Extraction Steam to FWH 21A 2-1EX-002 Text19: 26 9321-F-2020 M PEPSE ES?-2-1STPT ES TO FWH 21A:

NW Extraction Steam to FWH 21A 2-1EX-003 Text19: 26 9321-F-2020 M PEPSE ES?-3-1STPT ES TO FWH 21A: SW Extraction Steam to FWH 21A 2-1EX-004 Text19: 26 9321-F-2020 M PEPSE ES?-4-1STPT ES TO FWH 21A: SE Extraction Steam to FWH 21A 2-1EX-005 Text19: 26 9321-F-2020 M PEPSE ES?-1-1STPT ES TO FWH 21B: NE Extraction Steam to FWH 21B 2-1EX-006 Text19: 26 9321-F-2020 M PEPSE ES?-2-1STPT ES TO FWH 21B:

NW Extraction Steam to FWH 21B 2-1EX-007 Text19: 26 9321-F-2020 M PEPSE ES?-3-1STPT ES TO FWH 21B: SW Extraction Steam to FWH 21B 2-1EX-008 Text19: 26 9321-F-2020 M PEPSE ES?-4-1STPT ES TO FWH 21B: SE Extraction Steam to FWH 21B 2-1EX-009 Text19: 26 9321-F-2020 M PEPSE ES?-1-1STPT ES TO FWH 21C: NE Extraction Steam to FWH 21C 2-1EX-010 Text19: 26 9321-F-2020 M PEPSE ES?-2-1STPT ES TO FWH 21C:

NW Extraction Steam to FWH 21C 2-1EX-011 Text19: 26 9321-F-2020 M PEPSE ES?-3-1STPT ES TO FWH 21C:

SW Extraction Steam to FWH 21C 2-1EX-012 Text19: 26 9321-F-2020 M PEPSE ES?-4-1STPT ES TO FWH 21C: SE Extraction Steam to FWH 21C Report No. 0700.104-02, Appendix C, Revision 2 Page C-25 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section A: CHECWORKS Model Lines 2-2EX-01: LP Turbine Extraction Steam to #22 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-2EX-001-A 22 9321-F-2020 M PEPSE ES?-1-2NDPT ES TO FWH 22A: NE Extraction Steam to FWH 22A upstream of Exp. Joint 2-2EX-002-A Text19: 22 9321-F-2020 M PEPSE ES?-2-2NDPT ES TO FWH 22A:

SW Extraction Steam to FWH 22A upstream of Exp. Joint 2-2EX-003-A Text19: 22 9321-F-2020 M PEPSE ES?-1-2NDPT ES TO FWH 22B: NE Extraction Steam to FWH 22B upstream of Exp. Joint 2-2EX-004-A Text19: 22 9321-F-2020 M PEPSE ES?-2-2NDPT ES TO FWH 22B:

SW Extraction Steam to FWH 22B upstream of Exp. Joint 2-2EX-005-A Text19: 22 9321-F-2020 M PEPSE ES?-1-2NDPT ES TO FWH 22C: NE Extraction Steam to FWH 22C upstream of Exp. Joint Text19:

2-2EX-006-A 22 9321-F-2020 M PEPSE ES?-2-2NDPT ES TO FWH 22C:

SW Extraction Steam to FWH 22C upstream of Exp. Joint 2-3EX-01: Boiler Feed Pump Turbine Drains to Condensers Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-3EX-001 48 A227780 M PEPSE BFP #21 Drain to Condenser Text19:

2-3EX-002 48 A227780 M PEPSE BFP #22 Drain to Condenser Report No. 0700.104-02, Appendix C, Revision 2 Page C-26 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section A: CHECWORKS Model Lines 2-3EX-02: LP Turbine Extraction Steam to #23 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-3EX-003-A 20 9321-F-2020 M PEPSE ES1-1-3RDPT ES to FWH 23A: NW Extraction Steam to FWH 23A 2-3EX-003-B Text19: 20 9321-F-2020 M PEPSE ES1-2-3RDPT ES to FWH 23A: SE Extraction Steam to FWH 23A 2-3EX-003-C Text19: 28 9321-F-2020 M Sections of this line were replaced with PEPSE ES1-3-3RDPT ES to FWH 23A:

CrMo. These sections are modeled for Extraction Steam to FWH 23A continuity within the model.

2-3EX-004 Text19: 20 9321-F-2020 M Sections of this line were replaced with PEPSE ES1-4-3RDPT ES to FWH 23A:

CrMo. These sections are modeled for Extraction Steam to FWH 23A continuity within the model.

2-3EX-005 Text19: 20 9321-F-2020 M Sections of this line were replaced with PEPSE ES1-5-3RDPT ES to FWH 23A:

CrMo. These sections are modeled for Extraction Steam to FWH 23A continuity within the model.

2-3EX-006-A Text19: 20 9321-F-2020 M PEPSE ES2-1-3RDPT ES to FWH 23B: NW Extraction Steam to FWH 23B 2-3EX-006-B Text19: 20 9321-F-2020 M PEPSE ES2-2-3RDPT ES to FWH 23B: SE Extraction Steam to FWH 23B 2-3EX-006-C Text19: 28 9321-F-2020 M Sections of this line were replaced with PEPSE ES2-3-3RDPT ES to FWH 23B:

CrMo. These sections are modeled for Extraction Steam to FWH 23B continuity within the model.

2-3EX-007 Text19: 20 9321-F-2020 M Sections of this line were replaced with PEPSE ES2-4-3RDPT ES to FWH 23B:

CrMo. These sections are modeled for Extraction Steam to FWH 23B continuity within the model.

2-3EX-008 Text19: 20 9321-F-2020 M Sections of this line were replaced with PEPSE ES2-5-3RDPT ES to FWH 23B:

CrMo. These sections are modeled for Extraction Steam to FWH 23B continuity within the model.

2-3EX-009-A Text19: 20 9321-F-2020 M PEPSE ES3-1-3RDPT ES to FWH 23C: NW Extraction Steam to FWH 23C Report No. 0700.104-02, Appendix C, Revision 2 Page C-27 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section A: CHECWORKS Model Lines 2-3EX-02: LP Turbine Extraction Steam to #23 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-3EX-009-B 20 9321-F-2020 M PEPSE ES3-2-3RDPT ES to FWH 23C: SE Extraction Steam to FWH 23C 2-3EX-009-C Text19: 28 9321-F-2020 M Sections of this line were replaced with PEPSE ES3-3-3RDPT ES to FWH 23C:

CrMo. These sections are modeled for Extraction Steam to FWH 23C continuity within the model.

2-3EX-010 Text19: 20 9321-F-2020 M Sections of this line were replaced with PEPSE ES3-4-3RDPT ES to FWH 23C:

CrMo. These sections are modeled for Extraction Steam to FWH 23C continuity within the model.

2-3EX-011 Text19: 20 9321-F-2020 M Sections of this line were replaced with PEPSE ES3-5-3RDPT ES to FWH 23C:

CrMo. These sections are modeled for Extraction Steam to FWH 23C continuity within the model.

Section B: SNM Program Lines 2-3EX-01: Boiler Feed Pump Turbine Drains to Condensers Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3EX-021 1.5 A227780 S NC Unknown conditions in drip pocket to P&ID Continuous Drain from #21 Steam condenser Generator Feed Pump Turbine drain to #21 Condenser 2-3EX-022 Text19: 1.5 A227780 S NC Unknown conditions in drip pocket to P&ID Continuous Drain from #22 Steam condenser Generator Feed Pump Turbine drain to #22 Condenser 2-5EX-01: HP Turbine Crossunder Piping Drip Pots to the Condenser Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EX-025-A 2 A235308 S NS Flow Conditions Unknown PEPSE Crossunder Piping leakoff from Moisture Preseparator A upstream of Pipe Spec Change Report No. 0700.104-02, Appendix C, Revision 2 Page C-28 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section B: SNM Program Lines 2-5EX-01: HP Turbine Crossunder Piping Drip Pots to the Condenser Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EX-026-A 2 A235308 S NS Flow Conditions Unknown PEPSE Crossunder Piping leakoff from Moisture Preseparator B upstream of Pipe Spec Change 2-5EX-027-A Text19: 2 A235308 S NS Flow Conditions Unknown PEPSE Crossunder Piping leakoff from Moisture Preseparator C upstream of Pipe Spec Change 2-5EX-028-A Text19: 2 A235308 S NS Flow Conditions Unknown PEPSE Crossunder Piping leakoff from Moisture Preseparator D upstream of Pipe Spec Change 2-5EX-117 Text19: 1.5 B237145 S NS Operating conditions unknown. P&ID HP Turbine Drain Text19:

2-5EX-118 1.5 B237145 S NS Operating conditions unknown. P&ID Crossunder piping leakoff to FCV-1156 2-5EX-119 Text19: 1.5 B237145 S NS Operating conditions unknown. P&ID Crossunder piping leakoff to FCV-1164 2-5EX-120 Text19: 1.5 B237145 S NS Operating conditions unknown. P&ID Crossunder piping leakoff to FCV-1157 2-5EX-121 Text19: 1.5 B237145 S NS Operating conditions unknown. P&ID Crossunder piping leakoff to FCV-1165 2-5EX-122 Text19: B237145 S NS Operating conditions unknown. P&ID Crossunder piping to Moisture Separator Outlet Line 2-5EX-123 Text19: B237145 S NS Operating conditions unknown. P&ID Crossunder piping to Moisture Separator Outlet Line 2-5EX-124 Text19: B237145 S NS Operating conditions unknown. P&ID Crossunder piping to Moisture Separator Outlet Line 2-5EX-125 Text19: B237145 S NS Operating conditions unknown. P&ID Crossunder piping to Moisture Separator Outlet Line 2-5EX-128 Text19: B237145, B237144 S NC Operating conditions unknown. P&ID LP Leakoff Header to Gland Condenser Report No. 0700.104-02, Appendix C, Revision 2 Page C-29 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section B: SNM Program Lines 2-5EX-01: HP Turbine Crossunder Piping Drip Pots to the Condenser Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EX-129 1.5 B237145 S NS Operating conditions unknown. P&ID Crossunder piping leakoff to FCV1154 2-6EX-01: HP Turbine Extraction Steam to #26 Feedwater Heaters Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-6EX-001-A 12 9321-F-2020 S NL The nozzle is the only susceptible SFA Model ES8-1-6THPT ES to HDR: HP component in this line. Turbine Extraction Nozzle to #26 FWHs.

2-6EX-002-A Text19: 12 9321-F-2020 S NL The nozzle is the only susceptible SFA Model ES8-2-6THPT ES to HDR: HP component in this line. Turbine Extraction Nozzle to #26 FWHs.

2-6EX-006-B Text19: 12 9321-F-2020 S NL The nozzle is the only susceptible SFA Model ES8-7-6THPT ESHDR to FWH 26A:

component in this line. Extraction Steam Inlet Nozzle to FWH 26A.

Text19:

2-6EX-008-B 12 9321-F-2020 S NL The nozzle is the only susceptible SFA Model ES8-6-6THPT ESHDR to FWH 26B:

component in this line. Extraction Steam Inlet Nozzle to FWH 26B.

Text19:

2-6EX-010-B 12 9321-F-2020 S NL The nozzle is the only susceptible SFA Model ES8-4-6THPT ESHDR to FWH 26C:

component in this line. Extraction Steam Inlet Nozzle to FWH 26C.

Section C: Excluded Lines 2-2EX-01: LP Turbine Extraction Steam to #22 Feedwater Heaters Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-2EX-001-B 22 9321-F-2020 E EM This section of piping was replaced with Replacement History ES?-1-2NDPT ES TO FWH 22A: NE CrMo in 2R18 Extraction Steam to FWH 22A downstream of Exp. Joint Report No. 0700.104-02, Appendix C, Revision 2 Page C-30 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section C: Excluded Lines 2-2EX-01: LP Turbine Extraction Steam to #22 Feedwater Heaters Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-2EX-002-B 22 9321-F-2020 E EM This section of piping was replaced with Replacement History ES?-2-2NDPT ES TO FWH 22A:

CrMo in 2R18 SW Extraction Steam to FWH 22A downstream of Exp. Joint 2-2EX-003-B Text19: 22 9321-F-2020 E EM This section of piping was replaced with Replacement History ES?-1-2NDPT ES TO FWH 22B: NE CrMo in 2R18 Extraction Steam to FWH 22B downstream of Exp. Joint 2-2EX-004-B Text19: 22 9321-F-2020 E EM This section of piping was replaced with Replacement History ES?-2-2NDPT ES TO FWH 22B:

CrMo in 2R18 SW Extraction Steam to FWH 22B downstream of Exp. Joint 2-2EX-005-B Text19: 22 9321-F-2020 E EM Piping is CrMo. P&ID ES?-1-2NDPT ES TO FWH 22C: NE Extraction Steam to FWH 22C downstream of Exp. Joint 2-2EX-006-B Text19: 22 9321-F-2020 E EM Piping is CrMo. P&ID ES?-2-2NDPT ES TO FWH 22C:

SW Extraction Steam to FWH 22C downstream of Exp. Joint 2-5EX-01: HP Turbine Crossunder Piping Drip Pots to the Condenser Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EX-025-B 2 A235308 E EM Line is stainless steel. P&ID Crossunder Piping leakoff from Moisture Preseparator A downstream of Pipe Spec Change 2-5EX-026-B Text19: 2 A235308 E EM Line is stainless steel. P&ID Crossunder Piping leakoff from Moisture Preseparator B downstream of Pipe Spec Change 2-5EX-027-B Text19: 2 A235308 E EM Line is stainless steel. P&ID Crossunder Piping leakoff from Moisture Preseparator C downstream of Pipe Spec Change 2-5EX-028-B Text19: 2 A235308 E EM Line is stainless steel. P&ID Crossunder Piping leakoff from Moisture Preseparator D downstream of Pipe Spec Change Report No. 0700.104-02, Appendix C, Revision 2 Page C-31 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section C: Excluded Lines 2-5EX-01: HP Turbine Crossunder Piping Drip Pots to the Condenser Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EX-029 2 A235308 E EM Line is stainless steel. P&ID Crossunder Piping Leakoff Header from Moisture Preseparators A and B 2-5EX-030 Text19: 2 A235308 E EM Line is stainless steel. P&ID Crossunder Piping Leakoff Header from Moisture Preseparators C and D 2-5EX-115 Text19: 1.5 B237145 E EM Piping is SS P&ID HP Turbine Drain from Far Side Inlet Text19:

2-5EX-116 1.5 B237145 E EM Piping is SS P&ID HP Turbine Drain from Near Side Inlet Text19:

2-5EX-126 1.5 B237145 E EM Piping is SS P&ID Crossunder piping leakoff to 2-MS-200 2-5EX-127 Text19: 1.5 B237145 E EM Piping is SS P&ID Balancing line leakoff to 2-MS-201 2-5EX-03: Extraction Steam from Separating Tanks to #25 Feedwater Heaters Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EX-031 28 9321-F-2020 E EM Line is stainless steel. SFA Model ES7-1-5THPT ES to FWH 25ABC:

Extraction Steam Header to #25 Heaters Text19:

2-5EX-032 1.5 9321-F-2020 E EI Valve shown closed on P&ID. P&ID 5EX-1 Bypass Line Text19:

2-5EX-033 28 9321-F-2020 E EM Line is stainless steel. SFA Model ES7-3-5THPT ESHDR 25CT to BT:

Extraction Steam Header to FWH 25A and 25B 2-5EX-034 Text19: 18 9321-F-2020 E EM Line is stainless steel. SFA Model ES7-5-5THPT ESHDR to FWH 25A:

Extraction Steam Line to FWH 25A 2-5EX-035 Text19: 18 9321-F-2020 E EM Line is stainless steel. SFA Model ES7-4-5THPT ESHDR to FWH 25B:

Extraction Steam Line to FWH 25B 2-5EX-036 Text19: 18 9321-F-2020 E EM Line is stainless steel. SFA Model ES7-2-5THPT ESHDR to FWH 25C:

Extraction Steam Line to FWH 25C 2-5EX-037 Text19: 1.5 9321-F-2020 E EI Valve shown closed on P&ID. P&ID 5EX-5 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-32 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section C: Excluded Lines 2-5EX-03: Extraction Steam from Separating Tanks to #25 Feedwater Heaters Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5EX-038 1.5 9321-F-2020 E EI Valve shown closed on P&ID. P&ID 5EX-5-1 Bypass Line Text19:

2-5EX-039 1.5 9321-F-2020 E EI Valve shown closed on P&ID. P&ID 5EX-5-2 Bypass Line 2-6EX-01: HP Turbine Extraction Steam to #26 Feedwater Heaters Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-6EX-001-B 12 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-1-6THPT ES to HDR: HP with Stainless Steel. Turbine Extraction Line to #26 FWHs.

2-6EX-002-B Text19: 12 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-2-6THPT ES to HDR: HP with Stainless Steel. Turbine Extraction Line to #26 FWHs.

2-6EX-003 Text19: 18 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-3-6THPT ESHDR to FWH 26:

with Stainless Steel. HP Turbine Extraction Line to #26 FWHs.

Text19:

2-6EX-004 18 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-5-6THPT ESHDR 26CT to BT:

with Stainless Steel. Extraction Steam header to FWH 26A and 26B Text19:

2-6EX-005 12 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-7-6THPT ESHDR to FWH 26A:

with Stainless Steel. Extraction Steam to FWH 26A Upstream of VCD tie-in.

2-6EX-006-A Text19: 12 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-7-6THPT ESHDR to FWH 26A:

with Stainless Steel. Extraction Steam to FWH 26A Downstream of VCD tie-in.

2-6EX-007 Text19: 12 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-6-6THPT ESHDR to FWH 26B:

with Stainless Steel. Extraction Steam to FWH 26B Upstream of VCD tie-in.

2-6EX-008-A Text19: 12 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-6-6THPT ESHDR to FWH 26B:

with Stainless Steel. Extraction Steam to FWH 26B Downstream of VCD tie-in.

Report No. 0700.104-02, Appendix C, Revision 2 Page C-33 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Extraction Steam (EX), Unit 2 Section C: Excluded Lines 2-6EX-01: HP Turbine Extraction Steam to #26 Feedwater Heaters Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-6EX-009 12 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-4-6THPT ESHDR to FWH 26C:

with Stainless Steel. Extraction Steam to FWH 26C Upstream of VCD tie-in.

2-6EX-010-A Text19: 12 9321-F-2020 E EM Components in this line have been clad SFA Model ES8-4-6THPT ESHDR to FWH 26C:

with Stainless Steel. Extraction Steam to FWH 26C Downstream of VCD tie-in.

2-6EX-011 Text19: 1 9321-F-2020 E EI Valve shown closed on P&ID. P&ID 6EX-6 Bypass Line Text19:

2-6EX-012 1 9321-F-2020 E EI Valve shown closed on P&ID. P&ID 6EX-6-1 Bypass Line Text19:

2-6EX-013 1 9321-F-2020 E EI Valve shown closed on P&ID. P&ID 6EX-6-2 Bypass Line Text19:

2-6EX-014 1.5 9321-F-2020 E EI Valve shown closed on P&ID. P&ID 6EX-1 Bypass Line Text19:

2-6EX-017 1 9321-F-2020 E EI Valve shown closed on P&ID. P&ID FWH 26A Extraction Steam Line Drain 2-6EX-018 Text19: 1 9321-F-2020 E EI Valve shown closed on P&ID. P&ID FWH 26B Extraction Steam Line Drain 2-6EX-019 Text19: 1.5 9321-F-2020 E EI Valve shown closed on P&ID. P&ID FWH 26A and 26B Extraction Steam Line Drain Header 2-6EX-020 Text19: 1 9321-F-2020 E EI Valve shown closed on P&ID. P&ID FWH 26C Extraction Steam Line Drain 2-6EX-021 Text19: 2 9321-F-2020 E EI Valve shown closed on P&ID. P&ID #26 FWH Extraction Steam Line Drain Header Report No. 0700.104-02, Appendix C, Revision 2 Page C-34 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Feed Water (FW), Unit 2 Section A: CHECWORKS Model Lines 2-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-FW-001 20 9321-F-2019 M PEPSE FW71-1-BFP21 DISCH to HDR:

BFP No. 21 Discharge Upstream of Recirc Line 2-FW-002 Text19: 20 9321-F-2019 M PEPSE FW71-1-BFP21 DISCH to HDR:

BFP No. 21 Discharge Downstream of Recirc Line 2-FW-003 Text19: 20 9321-F-2019 M PEPSE FW72-1-BFP22 DISCH to HDR:

BFP No. 22 Discharge Upstream of Recirc Line 2-FW-004 Text19: 20 9321-F-2019 M PEPSE FW72-1-BFP22 DISCH to HDR:

BFP No. 22 Discharge Downstream of Recirc Line 2-FW-005 Text19: 30 9321-F-2019 M PEPSE FW73-1-BFPHDR to FWH26ABC:

BFP Discharge Header to #26 FWHs Upstream of High Pr. FWH Bypass Line 2-FW-006 Text19: 30 9321-F-2019 M PEPSE FW73-2-BFPHDR to FWH26ABC:

BFP Discharge Header to #26 FWHs Downstream of High Pr. FWH Bypass Line 2-FW-007 Text19: 30 9321-F-2019 M PEPSE FW73-4-BFPHDR to FWH26ABC:

BFP Discharge Header to FWHs 26A and 26B 2-FW-008 Text19: 18 9321-F-2019 M PEPSE FW73-6-BFPHDR to FWH26A:

Feedwater to FWH 26A 2-FW-009 Text19: 18 9321-F-2019 M PEPSE FW73-5-BFPHDR to FWH26B:

Feedwater to FWH 26B 2-FW-010 Text19: 18 9321-F-2019 M PEPSE FW73-3-BFPHDR to FWH26C:

Feedwater to FWH 26C Report No. 0700.104-02, Appendix C, Revision 2 Page C-35 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Feed Water (FW), Unit 2 Section A: CHECWORKS Model Lines 2-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-FW-020 18 9321-F-2019 M PEPSE FW74-1-FWH26A to DISHDR:

Feedwater from FWH 26A 2-FW-021 Text19: 18 9321-F-2019 M PEPSE FW74-2-FWH26B to DISHDR:

Feedwater from FWH 26B 2-FW-022 Text19: 18 9321-F-2019 M PEPSE FW74-4-FWH26C to DISHDR:

Feedwater from FWH 26C 2-FW-023 Text19: 30 9321-F-2019 M PEPSE FW74-3-FWH26 to DISHDR:

Feedwater Header from FWH 26A and 26B 2-FW-024 Text19: 30 9321-F-2019 M PEPSE FW74-5-FWH26 to DISHDR: #26 FWH Feedwater Discharge Header Upstream of Bypass Line 2-FW-025 Text19: 30 9321-F-2019 M PEPSE FW74-5-FWH26 to DISHDR: #26 FWH Feedwater Discharge Header Downstream of Bypass Line Text19:

2-FW-026 30 9321-F-2019 M PEPSE FW76-2-DISHDR to SG22:

Feedwater Header to Steam Generators Text19:

2-FW-027 30 9321-F-2019 M PEPSE FW76-2-DISHDR to SG22:

Feedwater Header to Steam Generators 2-FW-028 Text19: 30 9321-F-2019 M PEPSE FW77-2-DISHDR to SG24:

Feedwater Header to Steam Generators 2-FW-029 Text19: 30 9321-F-2019 M PEPSE FW77-2-DISHDR to SG24:

Feedwater Header to Steam Generators 2-FW-030 Text19: 30 9321-F-2019 M PEPSE FW78-1-DISHDR to SG23:

Feedwater Header to Steam Generators Report No. 0700.104-02, Appendix C, Revision 2 Page C-36 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Feed Water (FW), Unit 2 Section A: CHECWORKS Model Lines 2-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-FW-031 30 9321-F-2019 M PEPSE FW78-1-DISHDR to SG23:

Feedwater Header to Steam Generators 2-FW-032 Text19: 18 9321-F-2019 M PEPSE FW75-1-DISHDR to SG21:

Feedwater to 21 Steam Generator 2-FW-034 Text19: 18 9321-F-2019 M PEPSE FW76-1-DISHDR to SG22:

Feedwater to 22 Steam Generator 2-FW-036 Text19: 18 9321-F-2019 M PEPSE FW77-1-DISHDR to SG24:

Feedwater to 24 Steam Generator 2-FW-038 Text19: 18 9321-F-2019 M PEPSE FW78-1-DISHDR to SG23:

Feedwater to 23 Steam Generator 2-FW-058-A Text19: 18 9321-F-2019 M PEPSE FW75-1-DISHDR to SG21:

Feedwater to 21 Steam Generator Upstream of BFD-6 Text19:

2-FW-058-B 18 9321-F-2019 M Operating pressure from PEPSE model PEPSE FW75-1-DISHDR to SG21:

exceeds design pressure. Feedwater to 21 Steam Generator Downstream of BFD-6 Text19:

2-FW-059-A 18 9321-F-2019 M PEPSE FW76-1-DISHDR to SG22:

Feedwater to 22 Steam Generator Upstream of BFD-6-1 2-FW-059-B Text19: 18 9321-F-2019 M Operating pressure from PEPSE model PEPSE FW76-1-DISHDR to SG22:

exceeds design pressure. Feedwater to 22 Steam Generator Downstream of BFD-6-1 2-FW-060-A Text19: 18 9321-F-2019 M PEPSE FW77-1-DISHDR to SG24:

Feedwater to 24 Steam Generator Upstream of BFD-6-3 2-FW-060-B Text19: 18 9321-F-2019 M Operating pressure from PEPSE model PEPSE FW77-1-DISHDR to SG24:

exceeds design pressure. Feedwater to 24 Steam Generator Downstream of BFD-6-3 Report No. 0700.104-02, Appendix C, Revision 2 Page C-37 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Feed Water (FW), Unit 2 Section A: CHECWORKS Model Lines 2-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-FW-061-A 18 9321-F-2019 M PEPSE FW78-1-DISHDR to SG23:

Feedwater to 23 Steam Generator Upstream of BFD-6-2 2-FW-061-B Text19: 18 9321-F-2019 M Operating pressure from PEPSE model PEPSE FW78-1-DISHDR to SG23:

exceeds design pressure. Feedwater to 23 Steam Generator Downstream of BFD-6-2 Section B: SNM Program Lines 2-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-FW-031-A 30 9321-F-2019 S NC Flow Conditions Unknown P&ID Feedwater Header to Steam Generators downstream of Main Line to SG 23 Text19:

2-FW-062 0.75 9321-F-2019 S NS Operating conditions unknown. P&ID Feedwater to Sampling Upstream of BFD-1138 2-FW-03: Boiler Feed Pump Recirc Lines to the Drains Collecting Tank Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-FW-063 6 9321-F-2019 S NC Flow Conditions Unknown P&ID BFP No. 21 Recirc to Drains Collecting Tank 2-FW-064 Text19: 6 9321-F-2019 S NC Flow Conditions Unknown P&ID BFP No. 22 Recirc to Drains Collecting Tank Report No. 0700.104-02, Appendix C, Revision 2 Page C-38 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Feed Water (FW), Unit 2 Section C: Excluded Lines 2-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-FW-013 1 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-2-21 Bypass Line Text19:

2-FW-014 1 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-2-22 Bypass Line Text19:

2-FW-015 18 9321-F-2019 E EI Valve normally closed. CSI Doc# 0700.104.C.8 High Pr. FWH Bypass Line Text19:

2-FW-016 1.5 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-8 Bypass Line 2-FW-017 Text19: 1.5 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-3 Bypass Line Text19:

2-FW-018 1.5 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-3-1 Bypass Line Text19:

2-FW-019 1.5 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-3-2 Bypass Line Text19:

2-FW-033 6 9321-F-2019 E EM Piping Replaced with SS Previous SSE Feedwater min-flow line to 21 Steam Generator 2-FW-035 Text19: 6 9321-F-2019 E EM Piping Replaced with SS Previous SSE Feedwater min-flow line to 22 Steam Generator 2-FW-037 Text19: 6 9321-F-2019 E EM Piping Replaced with SS Previous SSE Feedwater min-flow line to 24 Steam Generator 2-FW-039 Text19: 6 9321-F-2019 E EM Piping Replaced with SS Previous SSE Feedwater min-flow line to 23 Steam Generator 2-FW-040 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain A from SG 23 Feedwater min-flow line.

2-FW-041 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain A from SG 24 Feedwater min-flow line.

2-FW-042 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain A header from SG 23 & 24 Feedwater min-flow lines.

2-FW-043 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain A from SG 22 Feedwater min-flow line.

2-FW-044 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain A header from SG 22, 23 & 24 Feedwater min-flow lines.

Report No. 0700.104-02, Appendix C, Revision 2 Page C-39 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Feed Water (FW), Unit 2 Section C: Excluded Lines 2-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-FW-045 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain A from SG 21 Feedwater min-flow line.

2-FW-046 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain A header from Feedwater min-flow lines.

2-FW-047 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain B from SG 23 Feedwater min-flow line.

2-FW-048 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain B from SG 24 Feedwater min-flow line.

2-FW-049 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain B header from SG 23 & 24 Feedwater min-flow lines.

2-FW-050 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain B from SG 22 Feedwater min-flow line.

2-FW-051 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain B header from SG 22, 23 & 24 Feedwater min-flow lines.

2-FW-052 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain B from SG 21 Feedwater min-flow line.

2-FW-053 Text19: 0.75 9321-F-2019 E EI Valve shown closed on P&ID. P&ID Drain B header from Feedwater min-flow lines.

2-FW-054 Text19: 1.5 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-5 Bypass Line Text19:

2-FW-055 1.5 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-5-1 Bypass Line Text19:

2-FW-056 1.5 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-5-3 Bypass Line Text19:

2-FW-057 1.5 9321-F-2019 E EI Valve shown closed on P&ID. P&ID BFD-5-2 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-40 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Gland Sealing Steam (GS), Unit 2 Section B: SNM Program Lines 2-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-GS-001 12 A235308 S NC Operating conditions unknown. P&ID Gland Seal Steam Header to HP and LP Turbines 2-GS-002 Text19: 10 A235308 S NC Operating conditions unknown. P&ID Gland Seal to HP Turbine Text19:

2-GS-003 10 A235308 S NC Operating conditions unknown. P&ID Gland Seal to HP Turbine Text19:

2-GS-004 6 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 21 Text19:

2-GS-005 2 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 21 Text19:

2-GS-006 6 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 21 Text19:

2-GS-007 2 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 21 Text19:

2-GS-008 6 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 22 Text19:

2-GS-009 2 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 22 Text19:

2-GS-010 6 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 22 Text19:

2-GS-011 2 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 22 Text19:

2-GS-012 6 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 23 Text19:

2-GS-013 2 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 23 Text19:

2-GS-014 6 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 23 Text19:

2-GS-015 2 A235308 S NC Operating conditions unknown. P&ID Gland Seal to LP Turbine 23 Text19:

2-GS-016 6 9321-H-2024 S NC Operating conditions unknown. P&IDs Gland Seal supply to BFP Turbines Text19:

2-GS-020 4 9321-H-2024 S NC Operating conditions unknown. P&IDs Steam to BFPT #22 Text19:

2-GS-021 4 9321-H-2024 S NC Operating conditions unknown. P&IDs Steam to BFPT #21 Text19:

2-GS-022 3 9321-H-2024 S NC Operating conditions unknown. P&IDs Steam to BFPT #22 Text19:

2-GS-023 3 9321-H-2024 S NC Operating conditions unknown. P&IDs Steam to BFPT #21 Report No. 0700.104-02, Appendix C, Revision 2 Page C-41 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Gland Sealing Steam (GS), Unit 2 Section B: SNM Program Lines 2-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-GS-032 3 9321-H-2024 S NC Operating conditions unknown. P&IDs BFPT #22 Gland Steam Discharge Text19:

2-GS-034 3 9321-H-2024 S NC Operating conditions unknown. P&IDs BFPT #21 Gland Steam Discharge Text19:

2-GS-036 6 9321-H-2024 S NC Operating conditions unknown. P&IDs BFPT Gland Steam Discharge Header to Gland Condenser 2-GS-038 Text19: 1 9321-H-2024, B237144 S NS Operating conditions unknown. P&ID BFPT Gland Steam Discharge Header drain to waste header 2-GS-039 Text19: 2 9321-H-2024 S NS Operating conditions unknown. P&ID BFPT #21 Exhaust Cylinder Drain Text19:

2-GS-040 2 9321-H-2024 S NS Operating conditions unknown. P&ID BFPT #22 Exhaust Cylinder Drain Text19:

2-GS-041 3 9321-H-2024 S NC Operating conditions unknown. P&IDs BFPT Exhaust Cylinder Drain header to Boiler Feed Pump Drip Tank 2-GS-042 Text19: 1 9321-H-2024 S NS Operating conditions unknown. P&ID BFPT Exhaust Cylinder Drain header line to Boiler Feed Pump Drip Tank vent Text19:

2-GS-043 3 9321-H-2024 S NC Operating conditions unknown. P&ID BFPT Drip Tank vent to Condenser

  1. 21 2-GS-047 Text19: B237145 S NC Operating conditions unknown. P&ID Gland Seal Return from HP Turbine Text19:

2-GS-048 B237145 S NC Operating conditions unknown. P&ID Gland Seal Return from HP Turbine Text19:

2-GS-049 B237144 S NC Operating conditions unknown. P&ID Gland Seal Return from #21 LP Turbine 2-GS-050 Text19: B237144 S NC Operating conditions unknown. P&ID Gland Seal Return from #21 LP Turbine 2-GS-051 Text19: B237144 S NC Operating conditions unknown. P&ID Gland Seal Return from #22 LP Turbine 2-GS-052 Text19: B237144 S NC Operating conditions unknown. P&ID Gland Seal Return from #22 LP Turbine Report No. 0700.104-02, Appendix C, Revision 2 Page C-42 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Gland Sealing Steam (GS), Unit 2 Section B: SNM Program Lines 2-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-GS-053 B237144 S NC Operating conditions unknown. P&ID Gland Seal Return from #23 LP Turbine 2-GS-054 Text19: B237144 S NC Operating conditions unknown. P&ID Gland Seal Return from #23 LP Turbine 2-GS-055 Text19: B237145, B237144 S NC Operating conditions unknown. P&ID Gland Seal return header to Gland Condenser 2-GS-056 Text19: B237144 S NM Outside modeling capabilities. PEPSE Gland Condenser Drain to Main Condenser Section C: Excluded Lines 2-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-GS-033 0.75 9321-H-2024 E EF Low flow in waste drain P&ID BFPT #22 Gland Steam Discharge Drain 2-GS-035 Text19: 0.75 9321-H-2024 E EF Low flow in waste drain P&ID BFPT #21 Gland Steam Discharge Drain 2-GS-037 Text19: 0.75 9321-H-2024 E EI Valve shown closed on P&ID. P&ID BFPT Gland Steam Discharge Header waste drain 2-GS-057 Text19: B237144 E EI Valve normally closed. Engineer Judgement Gland Condenser Waste Drain Report No. 0700.104-02, Appendix C, Revision 2 Page C-43 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Gland Steam Traps (GST), Unit 2 Section B: SNM Program Lines 2-GST-01: Steam Trap Lines from the Gland Seal System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-GST-017 0.75 9321-H-2024 S NS Operating conditions unknown. P&ID Steam to GST-1 Text19:

2-GST-019 0.75 9321-H-2024 S NS Operating conditions unknown. P&ID GST-1 Discharge to Header Text19:

2-GST-024 0.75 9321-H-2024 S NS Operating conditions unknown. P&ID Steam to GST-3 Text19:

2-GST-026 0.75 9321-H-2024 S NS Operating conditions unknown. P&ID GST-3 Discharge to Header 2-GST-027 Text19: 0.75 9321-H-2024 S NS Operating conditions unknown. P&ID Steam to GST-2 Text19:

2-GST-029 0.75 9321-H-2024 S NS Operating conditions unknown. P&ID GST-2 Discharge to Header Text19:

2-GST-030 2 9321-H-2024 S NS Operating conditions unknown. P&ID Header from GST-1 and 3 Text19:

2-GST-031 2 9321-H-2024 S NS Operating conditions unknown. P&ID Gland Steam Trap Header to Boiler Feed Pump Drip Tank Section C: Excluded Lines 2-GST-01: Steam Trap Lines from the Gland Seal System Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-GST-018 0.75 9321-H-2024 E EI Valve shown closed on P&ID. P&ID GST-1 Bypass Text19:

2-GST-025 0.75 9321-H-2024 E EI Valve shown closed on P&ID. P&ID GST-3 Bypass Text19:

2-GST-028 0.75 9321-H-2024 E EI Valve shown closed on P&ID. P&ID GST-2 Bypass Report No. 0700.104-02, Appendix C, Revision 2 Page C-44 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section A: CHECWORKS Model Lines 2-1HD-01: #21 Feedwater Heater Drain Lines Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-1HD-015 12 A235304 M Low temperature line with potential for PEPSE FWH 21A to Condenser 23 via LCV flashing 1124 2-1HD-016 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 21B to Condenser 22 via LCV flashing 1125 2-1HD-017 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 21C to Condenser 21 via LCV flashing 1126 2-2HD-01: #22 Feedwater Heater Drain Lines Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-2HD-007 12 A235304 M Low temperature line with potential for PEPSE FWH 22A Drain to FWH 21A flashing 2-2HD-008 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 22A Drain to FWH 21A flashing 2-2HD-009 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 22A Drain to FWH 21A flashing 2-2HD-010 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 22B Drain to FWH 21B flashing 2-2HD-011 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 22B Drain to FWH 21B flashing 2-2HD-012 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 22B Drain to FWH 21B flashing 2-2HD-013 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 22C Drain to FWH 21C flashing 2-2HD-014 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 22C Drain to FWH 21C flashing 2-2HD-015 Text19: 12 A235304 M Low temperature line with potential for PEPSE FWH 22C Drain to FWH 21C flashing Report No. 0700.104-02, Appendix C, Revision 2 Page C-45 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section A: CHECWORKS Model Lines 2-3HD-01: #23 Feedwater Heater Drain Lines Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-3HD-021 8 A235304 M PEPSE HD24A-1-FWH23A to CV, HD242A FWH23A CV to FWH22A: FWH 23A Drain to FWH 22A 2-3HD-022 Text19: 8 A235304 M PEPSE HD25A-1-FWH23B to CV, HD243A FWH23B CV to FWH22B: FWH 23B Drain to FWH 22B 2-3HD-023 Text19: 8 A235304 M PEPSE HD26A-1-FWH23C to CV, HD244A FWH23C CV to FWH22C: FWH 23C Drain to FWH 22C 2-4HD-01: #24 Feedwater Heater Drain Lines Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-4HD-010 6 A235304 M PEPSE HD21A-1-FWH24A to CV, HD21A FWH24A CV to FWH23A: FWH 24A Drain to FWH 23A Text19:

2-4HD-011 6 A235304 M PEPSE HD22A-1-FWH24B to CV, HD22A FWH24B CV to FWH23B: FWH 24B Drain to FWH 23B Text19:

2-4HD-012 6 A235304 M PEPSE HD23A-1-FWH24C to CV, HD23A FWH24C CV to FWH23C: FWH 24C Drain to FWH 23C 2-5HD-01: Heater Drains from #25 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-5HD-041 10 9321-F-2022 M PEPSE HD9-1-FWH25A to HTR DRN TK:

FWH 25A Drain to Heater Drain Tank 2-5HD-042 Text19: 10 9321-F-2022 M PEPSE HD9-2-FWH25B to HTR DRN TK:

FWH 25B Drain to Heater Drain Tank Report No. 0700.104-02, Appendix C, Revision 2 Page C-46 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section A: CHECWORKS Model Lines 2-5HD-01: Heater Drains from #25 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-5HD-043 10 9321-F-2022 M PEPSE HD9-3-FWH25C to HTR DRN TK:

FWH 25C Drain to Heater Drain Tank 2-5HD-03: HDT Drains to HDPs and Condensers and HDP Vents to HDT Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-5HD-055 18 9321-F-2022 M PEPSE HD19-1-HDT to HDP 21 SUCT: HDT to #21 HDP 2-5HD-056 Text19: 18 9321-F-2022 M PEPSE HD19-2-HDT to HDP 22 SUCT: HDT to #22 HDP 2-6HD-01: Heater Drains from #26 Feedwater Heaters Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-6HD-022-A 10 9321-F-2022 M PEPSE HD12-1-FWH26A to CV: Heater Drain from FWH 26A to LCV-1101 2-6HD-022-B Text19: 10 9321-F-2022 M This portion of line is CrMo. Modeled for Pipe Spec HD12-4-FWH26A CV to HTR DR continuity in SFA. TK: Heater Drain from LCV-1101 to Heater Drain Tank 2-6HD-023-A Text19: 10 9321-F-2022 M PEPSE HD12-2-FWH26B to CV: Heater Drain from FWH 26B to LCV-1102 2-6HD-023-B Text19: 10 9321-F-2022 M This portion of line is CrMo. Modeled for Pipe Spec HD12-5-FWH26B CV to HTR DR continuity in SFA. TK: Heater Drain from LCV-1102 to Heater Drain Tank 2-6HD-024-A Text19: 10 9321-F-2022 M PEPSE HD12-3-FWH26C to CV: Heater Drain from FWH 26C to LCV-1103 2-6HD-024-B Text19: 10 9321-F-2022 M This portion of line is CrMo. Modeled for Pipe Spec HD12-6-FWH26C CV to HTR DR continuity in SFA. TK: Heater Drain from LCV-1103 to Heater Drain Tank Report No. 0700.104-02, Appendix C, Revision 2 Page C-47 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section A: CHECWORKS Model Lines 2-HD-01: Heater Drain Pump discharge to Boiler Feed Pumps Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-HD-001 12 9321-F-2022 M PEPSE HD20-1-HDP21 to BFP SUCTION:

  1. 21 HDP to Heater Drain Pump Header 2-HD-002 Text19: 12 9321-F-2022 M PEPSE HD20-2-HDP22 to BFP SUCTION:
  1. 22 HDP to Heater Drain Pump Header 2-HD-003 Text19: 16 9321-F-2022 M PEPSE HD20-3-HDP DIS T to BFP SUC:

Heater Drain Pump Header to Boiler Feed Pumps Section B: SNM Program Lines 2-1HD-02: #21 Feedwater Heater Vents Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-1HD-021 6 A235304 S NC Operating conditions unknown. P&ID FWH 21A High Level Dump to Condenser 23 2-1HD-022 Text19: 6 A235304 S NC Operating conditions unknown. P&ID FWH 21B High Level Dump to Condenser 22 2-1HD-023 Text19: 6 A235304 S NC Operating conditions unknown. P&ID FWH 21C High Level Dump to Condenser 21 2-1HD-024 Text19: 5 A235304 S NC Operating conditions unknown. P&ID FWH 21A 5" Vent to Condenser 23 Text19:

2-1HD-025 5 A235304 S NC Operating conditions unknown. P&ID FWH 21B 5" Vent to Condenser 22 Text19:

2-1HD-026 5 A235304 S NC Operating conditions unknown. P&ID FWH 21C 5" Vent to Condenser 21 Text19:

2-1HD-027 1 A235304 S NS Operating conditions unknown. P&ID FWH 21A 1" Vent to Condenser 23 Text19:

2-1HD-028 1 A235304 S NS Operating conditions unknown. P&ID FWH 21B 1" Vent to Condenser 22 Report No. 0700.104-02, Appendix C, Revision 2 Page C-48 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section B: SNM Program Lines 2-1HD-02: #21 Feedwater Heater Vents Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-1HD-029 1 A235304 S NS Operating conditions unknown. P&ID FWH 21C 1" Vent to Condenser 21 2-2HD-02: #22 Feedwater Heater Vents Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-2HD-019 6 A235304 S NC Operating conditions unknown. P&ID FWH 22A High Level Dump to Condenser 23 2-2HD-020 Text19: 6 A235304 S NC Operating conditions unknown. P&ID FWH 22B High Level Dump to Condenser 22 2-2HD-021 Text19: 6 A235304 S NC Operating conditions unknown. P&ID FWH 22C High Level Dump to Condenser 21 2-2HD-022 Text19: 2.5 A235304 S NC Operating conditions unknown. P&ID FWH 22A 2-1/2" Vent to Condenser 23 2-2HD-023 Text19: 2.5 A235304 S NC Operating conditions unknown. P&ID FWH 22B 2-1/2" Vent to Condenser 22 2-2HD-024 Text19: 2.5 A235304 S NC Operating conditions unknown. P&ID FWH 22C 2-1/2" Vent to Condenser 21 2-2HD-025 Text19: 1 A235304 S NS Operating conditions unknown. P&ID FWH 22A 1" Vent to Condenser 23 Text19:

2-2HD-026 1 A235304 S NS Operating conditions unknown. P&ID FWH 22B 1" Vent to Condenser 22 Text19:

2-2HD-027 1 A235304 S NS Operating conditions unknown. P&ID FWH 22C 1" Vent to Condenser 21 2-3HD-02: #23 Feedwater Heater Vents Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3HD-027 2 A235304 S NS Operating conditions unknown. P&ID FWH 23A Vent to 3EX-53 Text19:

2-3HD-028 2 A235304 S NS Operating conditions unknown. P&ID FWH 23A Vent to 3EX-534 Report No. 0700.104-02, Appendix C, Revision 2 Page C-49 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section B: SNM Program Lines 2-3HD-02: #23 Feedwater Heater Vents Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3HD-029 2 A235304 S NS Operating conditions unknown. P&ID FWH 23B Vent to 3EX-536 Text19:

2-3HD-030 2 A235304 S NS Operating conditions unknown. P&ID FWH 23B Vent to 3EX-539 Text19:

2-3HD-031 2 A235304 S NS Operating conditions unknown. P&ID FWH 23C Vent to 3EX-541 Text19:

2-3HD-032 2 A235304 S NS Operating conditions unknown. P&ID FWH 23C Vent to 3EX-544 2-3HD-039 Text19: 3 A235304 S NC Operating conditions unknown. P&ID FWH 23A 3" Vent Header Text19:

2-3HD-040 3 A235304 S NC Operating conditions unknown. P&ID FWH 23B 3" Vent Header Text19:

2-3HD-041 3 A235304 S NC Operating conditions unknown. P&ID FWH 23C 3" Vent Header Text19:

2-3HD-042 4 A235304 S NC Operating conditions unknown. P&ID 4" Vent Header from FWH 23A and 23B 2-3HD-043 Text19: 4 A235304 S NC Operating conditions unknown. P&ID 4" Vent Header from #23 FWHs Text19:

2-3HD-044 1 A235304 S NS Operating conditions unknown. P&ID FWH 23A 1" Vent Text19:

2-3HD-045 1 A235304 S NS Operating conditions unknown. P&ID FWH 23B 1" Vent Text19:

2-3HD-046 1 A235304 S NS Operating conditions unknown. P&ID FWH 23C 1" Vent Text19:

2-3HD-047 2 A235304 S NS Operating conditions unknown. P&ID 2" Vent From FWH 23A and 23B Text19:

2-3HD-048 2 A235304 S NS Operating conditions unknown. P&ID 2" Vent From #23 FWHs 2-4HD-02: #24 Feedwater Heater Vents Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-4HD-016 1 A235304 S NS Operating conditions unknown. P&ID FWH 24A 1" Vent Text19:

2-4HD-017 1 A235304 S NS Operating conditions unknown. P&ID FWH 24B 1" Vent Text19:

2-4HD-018 1 A235304 S NS Operating conditions unknown. P&ID FWH 24C 1" Vent Report No. 0700.104-02, Appendix C, Revision 2 Page C-50 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section B: SNM Program Lines 2-4HD-02: #24 Feedwater Heater Vents Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-4HD-019 2 A235304 S NS Operating conditions unknown. P&ID 2" Vent Header from FWH 24A and 24B 2-4HD-020 Text19: 2 A235304 S NS Operating conditions unknown. P&ID 2" Vent Header from #24 FWHs to Condenser 22 2-4HD-021 Text19: 2 A235304 S NS Operating conditions unknown. P&ID FWH 24A 2" Vent Text19:

2-4HD-022 2 A235304 S NS Operating conditions unknown. P&ID FWH 24B 2" Vent Text19:

2-4HD-023 2 A235304 S NS Operating conditions unknown. P&ID FWH 24B 2" Vent Text19:

2-4HD-024 3 A235304 S NC Operating conditions unknown. P&ID 3" Vent Header from FWH 24A and 24B 2-4HD-025 Text19: 3 A235304 S NC Operating conditions unknown. P&ID 3" Vent Header from #24 FWHs to Condenser 22 2-5HD-02: Heater Vents from #25 Feedwater Heater and Heater Drain Tank vents to #25 Feedwater Heaters Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5HD-044 10 9321-F-2022 S NC Operating conditions unknown. PEPSE Heater Drain Tank vent to FWH 25A Text19:

2-5HD-045 10 9321-F-2022 S NC Operating conditions unknown. PEPSE Heater Drain Tank vent to FWH 25B Text19:

2-5HD-046 10 9321-F-2022 S NC Operating conditions unknown. PEPSE Heater Drain Tank vent to FWH 25C Text19:

2-5HD-047 1.5 9321-F-2022 S NS Operating conditions unknown. PEPSE FWH 25A Vent Text19:

2-5HD-048 1.5 9321-F-2022 S NS Operating conditions unknown. PEPSE FWH 25B Vent Text19:

2-5HD-049 1.5 9321-F-2022 S NS Operating conditions unknown. PEPSE FWH 25C Vent Text19:

2-5HD-050 2 9321-F-2022 S NS Operating conditions unknown. PEPSE Vent header from FWH 25A and 25B Text19:

2-5HD-051 2.5 9321-F-2022, A235304 S NS Operating conditions unknown. PEPSE #25 FWH Vent header to Condenser Report No. 0700.104-02, Appendix C, Revision 2 Page C-51 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section B: SNM Program Lines 2-5HD-03: HDT Drains to HDPs and Condensers and HDP Vents to HDT Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5HD-057 2 9321-F-2022 S NS Operating conditions unknown. P&ID #21 HDP vent to HDT Text19:

2-5HD-058 2 9321-F-2022 S NS Operating conditions unknown. P&ID #22 HDP vent to HDT Text19:

2-5HD-059 24 9321-F-2022, A235304 S NC Operating conditions unknown. PEPSE Heater Drain Tank drain to Condensers 2-5HD-060 Text19: 24 A235304 S NC Operating conditions unknown. PEPSE HDT Drain Header to Condensers 21 and 22 2-5HD-061-A Text19: 14 A235304 S NC Operating conditions unknown. PEPSE HDT Drain to LCV-5003 Text19:

2-5HD-061-B 8 A235304 S NC Operating conditions unknown. PEPSE LCV-5003 to Condenser 21 Text19:

2-5HD-062-A 14 A235304 S NC Operating conditions unknown. PEPSE HDT Drain to LCV-5002 Text19:

2-5HD-062-B 8 A235304 S NC Operating conditions unknown. PEPSE LCV-5002 to Condenser 22 Text19:

2-5HD-063-A 14 A235304 S NC Operating conditions unknown. PEPSE HDT Drain to LCV-5001 Text19:

2-5HD-063-B 8 A235304 S NC Operating conditions unknown. PEPSE LCV-5001 to Condenser 23 2-6HD-02: Heater Vents from #26 Feedwater Heater Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-6HD-025 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26A vent via 6EX-10 Text19:

2-6HD-026 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26A vent via 6EX-500 Text19:

2-6HD-027 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26A vent from 6EX-10 and 6EX-500 2-6HD-028 Text19: 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26A vent via 6EX-9 Text19:

2-6HD-029 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26B vent via 6EX-10-1 Text19:

2-6HD-030 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26B vent via 6EX-501 Report No. 0700.104-02, Appendix C, Revision 2 Page C-52 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section B: SNM Program Lines 2-6HD-02: Heater Vents from #26 Feedwater Heater Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-6HD-031 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26B vent from 6EX-10-1 and 6EX-501 2-6HD-032 Text19: 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26B vent via 6EX-9-1 Text19:

2-6HD-033 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26C vent via 6EX-10-2 Text19:

2-6HD-034 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26C vent via 6EX-502 Text19:

2-6HD-035 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26C vent from 6EX-10-2 and 6EX-502 2-6HD-036 Text19: 1 9321-F-2022 S NS Operating conditions unknown. P&IDs FWH 26C vent via 6EX-9-2 Text19:

2-6HD-037 1.5 9321-F-2022 S NS Operating conditions unknown. P&IDs Heater Start Up Vent Header from FWH 26A and 26B 2-6HD-038 Text19: 2 9321-F-2022, A235304 S NS Operating conditions unknown. P&IDs #26 FWH Startup Vent Header to Condenser 2-6HD-039 Text19: 1.5 9321-F-2022 S NS Operating conditions unknown. P&IDs Heater Vent Header from FWH 26A and 26B 2-6HD-040 Text19: 2 9321-F-2022, A235304 S NS Operating conditions unknown. P&IDs #26 FWH Vent Header to Condenser 2-HD-01: Heater Drain Pump discharge to Boiler Feed Pumps Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-HD-004-A 0.5 9321-F-2022 S NS Flow Conditions Unknown PEPSE #21 HDP to HDP Water Chem.

Monitor Upstream of Root Isolation Valve 2-HD-005-A Text19: 0.5 9321-F-2022 S NS Flow Conditions Unknown PEPSE #22 HDP to HDP Water Chem.

Monitor Upstream of Root Isolation Valve Report No. 0700.104-02, Appendix C, Revision 2 Page C-53 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section C: Excluded Lines 2-1HD-01: #21 Feedwater Heater Drain Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-1HD-018 12 A235304 E EI Valve shown closed on P&ID. P&ID FWH 21A to Condenser 23 via LCV 1124A 2-1HD-019 Text19: 12 A235304 E EI Valve shown closed on P&ID. P&ID FWH 21B to Condenser 22 via LCV 1125A 2-1HD-020 Text19: 12 A235304 E EI Valve shown closed on P&ID. P&ID FWH 21C to Condenser 21 via LCV 1126A 2-2HD-01: #22 Feedwater Heater Drain Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-2HD-016 12 A235304 E EI Valve shown closed on P&ID. P&ID FWH 22A Drain to Condenser 23 Text19:

2-2HD-017 12 A235304 E EI Valve shown closed on P&ID. P&ID FWH 22B Drain to Condenser 22 Text19:

2-2HD-018 12 A235304 E EI Valve shown closed on P&ID. P&ID FWH 22C Drain to Condenser 21 2-3HD-01: #23 Feedwater Heater Drain Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3HD-024 8 A235304 E EI Valve shown closed on P&ID. P&ID FWH 23A Drain to Condenser 23 Text19:

2-3HD-025 8 A235304 E EI Valve shown closed on P&ID. P&ID FWH 23B Drain to Condenser 22 Text19:

2-3HD-026 8 A235304 E EI Valve shown closed on P&ID. P&ID FWH 23C Drain to Condenser 21 2-3HD-02: #23 Feedwater Heater Vents Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3HD-033 A235304 E EI Valve shown closed on P&ID. P&ID Orifice Bypass via 3EX-11 Text19:

2-3HD-034 A235304 E EI Valve shown closed on P&ID. P&ID Orifice Bypass via 3EX-533 Report No. 0700.104-02, Appendix C, Revision 2 Page C-54 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section C: Excluded Lines 2-3HD-02: #23 Feedwater Heater Vents Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-3HD-035 A235304 E EI Valve shown closed on P&ID. P&ID Orifice Bypass via 3EX-11-1 Text19:

2-3HD-036 A235304 E EI Valve shown closed on P&ID. P&ID Orifice Bypass via 3EX-538 Text19:

2-3HD-037 A235304 E EI Valve shown closed on P&ID. P&ID Orifice Bypass via 3EX-11-2 Text19:

2-3HD-038 A235304 E EI Valve shown closed on P&ID. P&ID Orifice Bypass via 3EX-543 2-4HD-01: #24 Feedwater Heater Drain Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-4HD-013-A 6 A235304 E EI Valve shown closed on P&ID. P&ID FWH 24A Drain to LCV-1115A Text19:

2-4HD-013-B 6 A235304 E EI Valve shown closed on P&ID. P&ID LCV-1115A to Condenser 23 Text19:

2-4HD-014-A 6 A235304 E EI Valve shown closed on P&ID. P&ID FWH 24B Drain to LCV-1116A Text19:

2-4HD-014-B 6 A235304 E EI Valve shown closed on P&ID. P&ID LCV-1116A to Condenser 22 Text19:

2-4HD-015-A 6 A235304 E EI Valve shown closed on P&ID. P&ID FWH 24C Drain to LCV-1117A Text19:

2-4HD-015-B 6 A235304 E EI Valve shown closed on P&ID. P&ID LCV-1117A to Condenser 21 2-5HD-02: Heater Vents from #25 Feedwater Heater and Heater Drain Tank vents to #25 Feedwater Heaters Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5HD-052 9321-F-2022 E EI Valve shown closed on P&ID. P&ID FE-7635 Bypass Line Text19:

2-5HD-053 9321-F-2022 E EI Valve shown closed on P&ID. P&ID FE-7636 Bypass Line Text19:

2-5HD-054 9321-F-2022 E EI Valve shown closed on P&ID. P&ID FE-7637 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-55 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Heater Drains & Vents (HD), Unit 2 Section C: Excluded Lines 2-5HD-03: HDT Drains to HDPs and Condensers and HDP Vents to HDT Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-5HD-064 14 A235304 E EI Valve shown closed on P&ID. P&ID LCV-5003 Bypass Line Text19:

2-5HD-065 14 A235304 E EI Valve shown closed on P&ID. P&ID LCV-5002 Bypass Line Text19:

2-5HD-066 14 A235304 E EI Valve shown closed on P&ID. P&ID LCV-5001 Bypass Line 2-HD-01: Heater Drain Pump discharge to Boiler Feed Pumps Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-HD-004-B 0.25 9321-F-2022 E EM Downstream of root isolation valve is SS CSI Document No. #21 HDP to HDP Water Chem.

0700.104.C.010 Monitor Downstream of Root Isolation Valve 2-HD-005-B Text19: 0.25 9321-F-2022 E EM Downstream of root isolation valve is SS CSI Document No. #22 HDP to HDP Water Chem.

0700.104.C.010 Monitor Downstream of Root Isolation Valve Report No. 0700.104-02, Appendix C, Revision 2 Page C-56 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section A: CHECWORKS Model Lines 2-MS-07: HP Turbine Crossunder Piping to the Moisture Separators Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-MS-204 32 A235308 M PEPSE HP Turbine Crossunder to Moisture Preseparator A 2-MS-205 Text19: 32 A235308 M PEPSE HP Turbine Crossunder to Moisture Preseparator B 2-MS-206 Text19: 32 A235308 M PEPSE HP Turbine Crossunder to Moisture Preseparator C 2-MS-207 Text19: 32 A235308 M PEPSE HP Turbine Crossunder to Moisture Preseparator D Section B: SNM Program Lines 2-MS-01: Main Steam from Stm Gen to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-001 28 9321-F-2017, A235308 S NQ High quality main steam line. PEPSE Main Steam from Steam Generator 21 Shell 2-MS-002 Text19: 28 9321-F-2017, A235308 S NQ High quality main steam line. PEPSE Main Steam from Steam Generator 22 Shell 2-MS-003 Text19: 28 9321-F-2017, A235308 S NQ High quality main steam line. PEPSE Main Steam from Steam Generator 23 Shell 2-MS-004 Text19: 28 9321-F-2017, A235308 S NQ High quality main steam line. PEPSE Main Steam from Steam Generator 24 Shell 2-MS-005 Text19: 24 A235308 S NQ High quality main steam line. PEPSE Line from 2-MS-001 to Seal Steam and MSR Header.

2-MS-006 Text19: 24 A235308 S NQ High quality main steam line. PEPSE Line from 2-MS-002 to Gland Seal Steam and MSR B Header.

2-MS-007 Text19: 20 A235308, A227780 S NQ High quality main steam line. PEPSE Gland Seal Steam, MSR B, and Aux.

Steam Header.

Report No. 0700.104-02, Appendix C, Revision 2 Page C-57 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section B: SNM Program Lines 2-MS-01: Main Steam from Stm Gen to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-008 24 A235308 S NQ High quality main steam line. PEPSE Line from 2-MS-001 (3) to MSR A Header 2-MS-009 Text19: 24 A235308 S NQ High quality main steam line. PEPSE Line from 2-MS-004 to MSR A Header Text19:

2-MS-010 20 A235308, A227780 S NQ High quality main steam line. PEPSE MSR A, BFP Turbine, SJAE, and Priming Ejector Header 2-MS-011 Text19: 28 A235308 S NQ High quality main steam line. PEPSE Main Steam to NE HP Turbine Inlet Text19:

2-MS-011-A 4 A235308 S NQ High quality main steam line. PEPSE MS-863 Bypass Text19:

2-MS-012 28 A235308 S NQ High quality main steam line. PEPSE Main Steam to SE HP Turbine Inlet Text19:

2-MS-012-A 4 A235308 S NQ High quality main steam line. PEPSE MS-864 Bypass Text19:

2-MS-013 28 A235308 S NQ High quality main steam line. PEPSE Main Steam to NW HP Turbine Inlet Text19:

2-MS-013-A 4 A235308 S NQ High quality main steam line. PEPSE MS-865 Bypass Text19:

2-MS-014 28 A235308 S NQ High quality main steam line. PEPSE Main Steam to SW HP Turbine Inlet Text19:

2-MS-014-A 4 A235308 S NQ High quality main steam line. PEPSE MS-866 Bypass Text19:

2-MS-015 20 A235308 S NQ High quality main steam line. PEPSE Main Steam Balancing Line between 2-MS-001 and 2-MS-003 2-MS-016 Text19: 12 A227780 S NQ High quality main steam line. PEPSE Main Steam to Reheater Steam Control Station A.

2-MS-017 Text19: 8 A227780 S NQ High quality main steam line. PEPSE Reheater Steam Control Station A line to PCV 1175-1 2-MS-018 Text19: 8 A227780 S NQ High quality main steam line. PEPSE Reheater Steam Control Station A line to PCV 1175-2 2-MS-019 Text19: 1 A227780 S NS High quality main steam line. PEPSE Reheater Steam Control Station A line to PCV 1108 2-MS-020 Text19: 12 A227780 S NQ High quality main steam line. PEPSE Reheater Steam Header A Report No. 0700.104-02, Appendix C, Revision 2 Page C-58 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section B: SNM Program Lines 2-MS-01: Main Steam from Stm Gen to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-021 6 A227780 S NQ High quality main steam line. PEPSE Reheater Header to MSR 21A Text19:

2-MS-022 6 A227780 S NQ High quality main steam line. PEPSE Reheater Header to MSR 22A Text19:

2-MS-023 6 A227780 S NQ High quality main steam line. PEPSE Reheater Header to MSR 23A Text19:

2-MS-024 12 A227780 S NQ High quality main steam line. PEPSE Main Steam to Reheater Steam Control Station B.

2-MS-025 Text19: 8 A227780 S NQ High quality main steam line. PEPSE Reheater Steam Control Station B line to PCV 1175-3 2-MS-026 Text19: 8 A227780 S NQ High quality main steam line. PEPSE Reheater Steam Control Station B line to PCV 1175-4 2-MS-027 Text19: 1 A227780 S NS High quality main steam line. PEPSE Reheater Steam Control Station B line to PCV 1109 2-MS-028 Text19: 12 A227780 S NQ High quality main steam line. PEPSE Reheater Steam Header B Text19:

2-MS-029 6 A227780 S NQ High quality main steam line. PEPSE Reheater Header to MSR 21B Text19:

2-MS-030 6 A227780 S NQ High quality main steam line. PEPSE Reheater Header to MSR 22B Text19:

2-MS-031 6 A227780 S NQ High quality main steam line. PEPSE Reheater Header to MSR 23B Text19:

2-MS-032 1 A227780 S NS High quality main steam line. PEPSE Reheater Cal. Line Text19:

2-MS-033 4 A227780 S NQ High quality main steam line. PEPSE Main Steam to BFP #21 Turbine Text19:

2-MS-034 4 A227780 S NQ High quality main steam line. PEPSE Main Steam to BFP #22 Turbine Text19:

2-MS-035 6 A227780 S NQ High quality main steam line. PEPSE Main Steam to SJAEs and Priming Ejectors 2-MS-036-A Text19: 3 A227780 S NQ High quality main steam line. PEPSE SJAE Steam Supply Upstream of PCV 1132 2-MS-036-B Text19: 3 A227780 S NC Operating conditions unknown. SD No. 18.0 SJAE Steam Supply Downstream of PCV 1132 Report No. 0700.104-02, Appendix C, Revision 2 Page C-59 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section B: SNM Program Lines 2-MS-01: Main Steam from Stm Gen to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-037 3 A227780 S N Operating conditions unknown. SD No. 18.0 SJAE Header Text19:

2-MS-038 2 A227780 S NS Operating conditions unknown. SD No. 18.0 Header to SJAE 21 Text19:

2-MS-039 2 A227780 S NS Operating conditions unknown. SD No. 18.0 Header to SJAE 22 Text19:

2-MS-040 2 A227780 S NS Operating conditions unknown. SD No. 18.0 Header to SJAE 23 2-MS-041 Text19: A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-797 Text19:

2-MS-042 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-798 Text19:

2-MS-043 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-799 Text19:

2-MS-044 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-800 Text19:

2-MS-045 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-801 Text19:

2-MS-046 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-802 Text19:

2-MS-047 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-803 Text19:

2-MS-048 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-804 Text19:

2-MS-049 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-805 Text19:

2-MS-050 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-806 Text19:

2-MS-051 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-807 Text19:

2-MS-052 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-808 Text19:

2-MS-053 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-809 Text19:

2-MS-054 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-810 Text19:

2-MS-055 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-811 Text19:

2-MS-056 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-812 Report No. 0700.104-02, Appendix C, Revision 2 Page C-60 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section B: SNM Program Lines 2-MS-01: Main Steam from Stm Gen to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-057 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-813 Text19:

2-MS-058 A227780 S NS Operating conditions unknown. SD No. 18.0 SJAE Steam Supply via MS-814 Text19:

2-MS-059-A 6 A227780 S NQ High quality main steam line. PEPSE Main Steam to Priming Ejectors Header Upstream of PCV 1133 2-MS-059-B Text19: 6 A227780 S N Operating conditions unknown. SD No. 18.0 Main Steam to Priming Ejectors Header Downstream of PCV 1133 2-MS-060 Text19: 6 A227780 S N Operating conditions unknown. SD No. 18.0 Priming Ejectors Header Text19:

2-MS-061 3 A227780 S N Operating conditions unknown. SD No. 18.0 Priming Ejectors Header to PE 21 Text19:

2-MS-062 3 A227780 S N Operating conditions unknown. SD No. 18.0 Priming Ejectors Header to PE 22 Text19:

2-MS-063 3 A227780 S N Operating conditions unknown. SD No. 18.0 Priming Ejectors Header to PE 23 Text19:

2-MS-064 12 A235308 S NQ High quality main steam line. PEPSE Balancing line between SE and SW HP Turbine Steam Feed Lines.

2-MS-076 Text19: 3 A235308 S NC Operating conditions unknown. P&ID MS-863 Valve leakoff to condenser.

Text19:

2-MS-077 3 A235308 S NC Operating conditions unknown. P&ID MS-864 Valve leakoff to condenser.

Text19:

2-MS-078 3 A235308 S NC Operating conditions unknown. P&ID MS-865 Valve leakoff to condenser.

Text19:

2-MS-079 3 A235308 S NC Operating conditions unknown. P&ID MS-866 Valve leakoff to condenser.

Text19:

2-MS-143 0.75 A235308 S NS Operating conditions unknown. P&ID Main Steam Stop Valve drain to 23 Cond. West Side 2-MS-144 Text19: 0.75 A235308 S NS Operating conditions unknown. P&ID Main Steam Stop Valve drain to 23 Cond. East Side 2-MS-192 Text19: 4 A227780 S NQ High quality main steam line. PEPSE Main Steam Header to Aux. Steam Upstream of PCV-1015 2-MS-198 Text19: B237145 S NS Operating conditions unknown. P&ID LH Control Valve Stem Leak-off Lines Report No. 0700.104-02, Appendix C, Revision 2 Page C-61 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section B: SNM Program Lines 2-MS-01: Main Steam from Stm Gen to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-199 B237145 S NS Operating conditions unknown. P&ID RH Control Valve Stem Leak-off Lines Text19:

2-MS-200 1.5 B237145 S NS Operating conditions unknown. P&ID Upper LH HP Turbine Feed Leakoff Text19:

2-MS-201 1.5 B237145 S NS Operating conditions unknown. P&ID Lower LH HP Turbine Feed Leakoff Text19:

2-MS-202 1.5 B237145 S NS Operating conditions unknown. P&ID Upper RH HP Turbine Feed Leakoff 2-MS-203 Text19: 1.5 B237145 S NS Operating conditions unknown. P&ID Lower LH HP Turbine Feed Leakoff 2-MS-06: Main Steam Supply to Gland Steam Header Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-187 4 A235308 S NQ High quality main steam line. PEPSE Main Steam Supply to Gland Seal Regulator Station 2-MS-188-A Text19: 3 A235308 S NQ High quality main steam line. PEPSE Gland Seal Steam Supply upstream of PCV-1145-1 2-MS-188-B Text19: 12 A235308 S NC Operating conditions unknown. P&ID Gland Seal Steam Supply downstream of PCV-1145-1 2-MS-189-A Text19: 3 A235308 S NQ High quality main steam line. PEPSE Gland Seal Steam Supply upstream of PCV-1145-2 2-MS-189-B Text19: 12 A235308 S NC Operating conditions unknown. P&ID Gland Seal Steam Supply downstream of PCV-1145-2 2-MS-191 Text19: 12 A235308 S NC Operating conditions unknown. P&ID Main Steam to Gland Seal Steam Header.

Report No. 0700.104-02, Appendix C, Revision 2 Page C-62 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section C: Excluded Lines 2-MS-01: Main Steam from Stm Gen to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-036-C 2 A227780 E EI Valve shown closed on P&ID. P&ID PCV 1132 Bypass Line Text19:

2-MS-059-C 6 A227780 E EI Valve shown closed on P&ID. P&ID PCV 1133 Bypass Line Text19:

2-MS-065 4 9321-F-2017 E EI Aux. FW Turbine does not run during SD No. 18.0 Aux. Feed Pump Turbine Drive normal operation. Steam Supply from SG 22 Shell 2-MS-066 Text19: 4 9321-F-2017 E EI Aux. FW Turbine does not run during SD No. 18.0 Aux. Feed Pump Turbine Drive normal operation. Steam Supply from SG 23 Shell 2-MS-067-A Text19: 4 9321-F-2017 E EI Aux. FW Turbine does not run during SD No. 18.0 Aux. Feed Pump Turbine Drive normal operation. Steam Header Upstream of PCV 1139 2-MS-067-B Text19: 4 9321-F-2017 E EI Aux. FW Turbine does not run during SD No. 18.0 Aux. Feed Pump Turbine Drive normal operation. Steam Header Downstream of PCV 1139 2-MS-068 Text19: 1 9321-F-2017 E EI Valve shown closed on P&ID. P&ID PCV 1310A Bypass Line Text19:

2-MS-069 1 9321-F-2017 E EI Valve shown closed on P&ID. P&ID PCV 1310A and 1310B Equalization Line 2-MS-070 Text19: 1 9321-F-2017 E EI Valve shown closed on P&ID. P&ID PCV 1310B Bypass Line Text19:

2-MS-071 12 9321-F-2017 E EI Aux. FW Turbine does not run during SD No. 18.0 Aux. Feed Pump Turbine Drive Vent normal operation. to Atmosphere.

2-MS-072 Text19: 0.75 9321-F-2041 E EI The Aux. Feed Turbine operates less than SD No. 21.0 Aux. Feed Pump Turbine Drive Vent 2% of the time. Drip Leg 2-MS-181 Text19: 1 A209847 E EI FCV-5066B normally closed SD No. 18.0 PCV-1175-1 Leakoff Line to Condenser 2-MS-182 Text19: 1 A209847 E EI FCV-5066A normally closed SD No. 18.0 PCV-1175-2 Leakoff Line to Condenser 2-MS-183 Text19: 1 A209847 E EI FCV-5065B normally closed SD No. 18.0 PCV-1175-3 Leakoff Line to Condenser Report No. 0700.104-02, Appendix C, Revision 2 Page C-63 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section C: Excluded Lines 2-MS-01: Main Steam from Stm Gen to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-184 1 A209847 E EI FCV-5065A normally closed SD No. 18.0 PCV-1175-4 Leakoff Line to Condenser 2-MS-185 Text19: 2 A209847 E EI Upstream valves normally closed SD No. 18.0 PCV-1175-1 and 2 Leakoff Header to Condenser 2-MS-186 Text19: 2 A209847 E EI Upstream valves normally closed SD No. 18.0 PCV-1175-3 and 4 Leakoff Header to Condenser 2-MS-194 Text19: 1 A227780 E EI Valve shown closed on P&ID. P&ID MS-1133 Bypass Text19:

2-MS-195 0.75 A227780 E EI Valve shown closed on P&ID. P&ID MST-100 Bypass via MS-1139 and MS-1140 2-MS-197 Text19: 3 A227780 E EI Valve shown closed on P&ID. P&ID PCV-1015 Bypass 2-MS-06: Main Steam Supply to Gland Steam Header Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-190 3 A235308 E EI Valve shown closed on P&ID. P&ID PCV-1145-1 and 2 bypass line 2-MS-07: HP Turbine Crossunder Piping to the Moisture Separators Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-208 32 A235308 E EM Line is clad with Stainless Steel. SFA Model MS56-1-PRESEP to MSR-A:

Moisture Preseparator A to MSR Header 2-MS-209 Text19: 32 A235308 E EM Line is clad with Stainless Steel. SFA Model MS57-1-PRESEP to MSR-B:

Moisture Preseparator B to MSR Header 2-MS-210 Text19: 32 A235308 E EM Line is clad with Stainless Steel. SFA Model MS56-2-PRESEP to MSR-A:

Moisture Preseparator C to MSR Header Report No. 0700.104-02, Appendix C, Revision 2 Page C-64 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section C: Excluded Lines 2-MS-07: HP Turbine Crossunder Piping to the Moisture Separators Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-211 32 A235308 E EM Line is clad with Stainless Steel. SFA Model MS57-2-PRESEP to MSR-B:

Moisture Preseparator D to MSR Header 2-MS-212 Text19: 46.5 A235308, A227780 E EM Line is clad with Stainless Steel. SFA Model MS56-3-PRESEP to MSR-A:

Moisture Preseparator Header to A MSRs 2-MS-213 Text19: 46.5 A235308, A227780 E EM Line is clad with Stainless Steel. SFA Model MS57-3-PRESEP to MSR-B:

Moisture Preseparator Header to B MSRs 2-MS-214 Text19: 37 A227780 E EM Line is clad with Stainless Steel. SFA Model MS56-5-PRESEP to MSR-A:

Moisture Preseparator Header to MSR 21A and 22A 2-MS-215 Text19: 37 A227780 E EM Line is clad with Stainless Steel. SFA Model MS57-5-PRESEP to MSR-B:

Moisture Preseparator Header to MSR 21B and 22B Text19:

2-MS-216 26.5 A227780 E EM Line is clad with Stainless Steel. SFA Model MS56-7-PRESEP to MSR21A:

Moisture Preseparator Header to MSR 21A Text19:

2-MS-217 26.5 A227780 E EM Line is clad with Stainless Steel. SFA Model MS56-6-PRESEP to MSR22A:

Moisture Preseparator Header to MSR 22A 2-MS-218 Text19: 26.5 A227780 E EM Line is clad with Stainless Steel. SFA Model MS56-4-PRESEP to MSR23A:

Moisture Preseparator Header to MSR 23A 2-MS-219 Text19: 26.5 A227780 E EM Line is clad with Stainless Steel. SFA Model MS57-7-PRESEP to MSR21B:

Moisture Preseparator Header to MSR 21B 2-MS-220 Text19: 26.5 A227780 E EM Line is clad with Stainless Steel. SFA Model MS57-6-PRESEP to MSR22B:

Moisture Preseparator Header to MSR 22B Report No. 0700.104-02, Appendix C, Revision 2 Page C-65 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam (MS), Unit 2 Section C: Excluded Lines 2-MS-07: HP Turbine Crossunder Piping to the Moisture Separators Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MS-221 26.5 A227780 E EM Line is clad with Stainless Steel. SFA Model MS57-4-PRESEP to MSR23B:

Moisture Preseparator Header to MSR 23B Report No. 0700.104-02, Appendix C, Revision 2 Page C-66 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section A: CHECWORKS Model Lines 2-MSD-01: Moisture Separator Drains to the Heater Drain Tank and Drains Collecting Tank Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-MSD-067 12 9321-F-2023 M PEPSE MSD27-1-MS21A to MSDT 21A:

MSR 21A Drain from 16N 2-MSD-068 Text19: 12 9321-F-2023 M PEPSE MSD27-2-MS21A to MSDT 21A:

MSR 21A Drain from 17N 2-MSD-069 Text19: 12 9321-F-2023 M PEPSE MSD27-4-MS21A to MSDT 21A:

MSR 21A Drain Header from 16N and 17N 2-MSD-070 Text19: 12 9321-F-2023 M PEPSE MSD27-3-MS21A to MSDT 21A:

MSR 21A Drain from 19N 2-MSD-071 Text19: 12 9321-F-2023 M PEPSE MSD27-5-MS21A to MSDT 21A:

MSR 21A Drain to MSR Drain Tank 21A 2-MSD-072 Text19: 12 9321-F-2023 M PEPSE MSD28-1-MS22A to MSDT 22A:

MSR 22A Drain from 16N 2-MSD-073 Text19: 12 9321-F-2023 M PEPSE MSD28-2-MS22A to MSDT 22A:

MSR 22A Drain from 17N 2-MSD-074 Text19: 12 9321-F-2023 M PEPSE MSD28-4-MS22A to MSDT 22A:

MSR 22A Drain Header from 16N and 17N 2-MSD-075 Text19: 12 9321-F-2023 M PEPSE MSD28-3-MS22A to MSDT 22A:

MSR 22A Drain from 19N 2-MSD-076 Text19: 12 9321-F-2023 M PEPSE MSD28-5-MS22A to MSDT 22A:

MSR 22A Drain to MSR Drain Tank 22A 2-MSD-077 Text19: 12 9321-F-2023 M PEPSE MSD29-1-MS23A to MSDT 23A:

MSR 23A Drain from 16N 2-MSD-078 Text19: 12 9321-F-2023 M PEPSE MSD29-2-MS23A to MSDT 23A:

MSR 23A Drain from 17N Report No. 0700.104-02, Appendix C, Revision 2 Page C-67 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section A: CHECWORKS Model Lines 2-MSD-01: Moisture Separator Drains to the Heater Drain Tank and Drains Collecting Tank Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-MSD-079 12 9321-F-2023 M PEPSE MSD29-4-MS23A to MSDT 23A:

MSR 23A Drain Header from 16N and 17N 2-MSD-080 Text19: 12 9321-F-2023 M PEPSE MSD29-3-MS23A to MSDT 23A:

MSR 23A Drain from 19N 2-MSD-081 Text19: 12 9321-F-2023 M PEPSE MSD29-5-MS23A to MSDT 23A:

MSR 23A Drain to MSR Drain Tank 23A 2-MSD-082 Text19: 12 9321-F-2023 M PEPSE MSD30-1-MS21B to MSDT 21B:

MSR 21B Drain from 19N 2-MSD-083 Text19: 12 9321-F-2023 M PEPSE MSD30-2-MS21B to MSDT 21B:

MSR 21B Drain from 18N 2-MSD-084 Text19: 12 9321-F-2023 M PEPSE MSD30-4-MS21B to MSDT 21B:

MSR 21B Drain Header from 18N and 19N Text19:

2-MSD-085 12 9321-F-2023 M PEPSE MSD30-3-MS21B to MSDT 21B:

MSR 21B Drain from 16N 2-MSD-086 Text19: 12 9321-F-2023 M PEPSE MSD30-5-MS21B to MSDT 21B:

MSR 21B Drain to MSR Drain Tank 21B 2-MSD-087 Text19: 12 9321-F-2023 M PEPSE MSD31-1-MS22B to MSDT 22B:

MSR 22B Drain from 19N 2-MSD-088 Text19: 12 9321-F-2023 M PEPSE MSD31-2-MS22B to MSDT 22B:

MSR 22B Drain from 18N 2-MSD-089 Text19: 12 9321-F-2023 M PEPSE MSD31-4-MS22B to MSDT 22B:

MSR 22B Drain Header from 18N and 19N 2-MSD-090 Text19: 12 9321-F-2023 M PEPSE MSD31-3-MS22B to MSDT 22B:

MSR 22B Drain from 16N Report No. 0700.104-02, Appendix C, Revision 2 Page C-68 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section A: CHECWORKS Model Lines 2-MSD-01: Moisture Separator Drains to the Heater Drain Tank and Drains Collecting Tank Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-MSD-091 12 9321-F-2023 M PEPSE MSD31-5-MS22B to MSDT 22B:

MSR 22B Drain to MSR Drain Tank 22B 2-MSD-092 Text19: 12 9321-F-2023 M PEPSE MSD32-1-MS23B to MSDT 23B:

MSR 23B Drain from 19N 2-MSD-093 Text19: 12 9321-F-2023 M PEPSE MSD32-2-MS23B to MSDT 23B:

MSR 23B Drain from 18N 2-MSD-094 Text19: 12 9321-F-2023 M PEPSE MSD32-4-MS23B to MSDT 23B:

MSR 23B Drain Header from 18N and 19N 2-MSD-095 Text19: 12 9321-F-2023 M PEPSE MSD32-3-MS23B to MSDT 23B:

MSR 23B Drain from 16N 2-MSD-096 Text19: 12 9321-F-2023 M PEPSE MSD32-5-MS23B to MSDT 23B:

MSR 23B Drain to MSR Drain Tank 23B 2-MSD-02: Reheater Drains to #26 Feedwater Heaters and Condensers Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-MSD-151 6 9321-F-2023 M PEPSE MSD39-1-RHTR 21A to RHDT 21A:

Reheater 21A to Reheater Drain Tank 2-MSD-152 Text19: 6 9321-F-2023 M PEPSE MSD40-1-RHTR 22A to RHDT 22A:

Reheater 22A to Reheater Drain Tank 2-MSD-153 Text19: 6 9321-F-2023 M PEPSE MSD41-1-RHTR 23A to RHDT 23A:

Reheater 23A to Reheater Drain Tank 2-MSD-154 Text19: 6 9321-F-2023 M PEPSE MSD42-1-RHTR 21B to RHDT 21B:

Reheater 21B to Reheater Drain Tank 2-MSD-155 Text19: 6 9321-F-2023 M PEPSE MSD43-1-RHTR 22B to RHDT 22B:

Reheater 22B to Reheater Drain Tank Report No. 0700.104-02, Appendix C, Revision 2 Page C-69 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section A: CHECWORKS Model Lines 2-MSD-02: Reheater Drains to #26 Feedwater Heaters and Condensers Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-MSD-156 6 9321-F-2023 M PEPSE MSD44-1-RHTR 23B to RHDT 23B:

Reheater 23B to Reheater Drain Tank 2-MSD-157 Text19: 6 9321-F-2023 M Components downstream of the control PEPSE MSD45A-1-RHDT21A to CV, valve in this line have been replaced with MSD45B-1-RHDT21A CV to stainless steel. These components are FWH26: Reheater Drain Tank 21A modeled for continuity. Drain to Header 2-MSD-158 Text19: 8 9321-F-2023 M Components downstream of the control PEPSE MSD46A-1-RHDT22A to CV, valve in this line have been replaced with MSD46A-2-RHDT22A CV to stainless steel. These components are FWH26: Reheater Drain Tank 22A modeled for continuity. Drain to Header 2-MSD-159 Text19: 6 9321-F-2023 M PEPSE MSD47-1-RHDT23A to CV, MSD47 RHDT23A CV to FWH26: Reheater Drain Tank 23A Drain to Header 2-MSD-160 Text19: 10 9321-F-2023 M PEPSE MSD45C-1-RHDT A HDR to FWH26, MSD45C-2-RHDT A HDR to FWH26: Reheater Drain Tank Header 2-MSD-161 Text19: 10 9321-F-2023 M PEPSE MSD45C-3-RHDT A HDR to FWH26: "A" Reheater Drain Tank Header to #26 FWHs Text19:

2-MSD-162 8 9321-F-2023 M PEPSE MSD45C-5-RHDT A HDR to FWH26: "A" Reheater Drain Tank Header to FWH 26A and 26B 2-MSD-163 Text19: 6 9321-F-2023 M PEPSE MSD45D-2-RHDT A HDR to FWH26A: "A" Reheater Drain Tank Header to FWH 26A 2-MSD-164 Text19: 6 9321-F-2023 M PEPSE MSD45D-1-RHDT A HDR to FWH26B: "A" Reheater Drain Tank Header to FWH 26B Report No. 0700.104-02, Appendix C, Revision 2 Page C-70 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section A: CHECWORKS Model Lines 2-MSD-02: Reheater Drains to #26 Feedwater Heaters and Condensers Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-MSD-165 6 9321-F-2023 M A portion of this line has been replaced PEPSE MSD45C-4-RHDT A HDR to with stainless steel. These components FWH26C: "A" Reheater Drain Tank are modeled for continuity. Header to FWH 26C 2-MSD-166 Text19: 6 9321-F-2023 M PEPSE MSD48A-1-RHDT21B to CV, MSD48B-1-RHDT21B CV to FWH26: Reheater Drain Tank 21B Drain to Header 2-MSD-167 Text19: 10 9321-F-2023 M PEPSE MSD49A-1-RHDT22B to CV, MSD49B-1-RHDT22B CV to FWH26: Reheater Drain Tank 22B Drain to Header 2-MSD-168 Text19: 6 9321-F-2023 M PEPSE MSD50A-1-RHDT23B to CV, MSD50C-1-RHDT23B CV to FWH26: Reheater Drain Tank 23B Drain to Header 2-MSD-169 Text19: 8 9321-F-2023 M PEPSE MSD48B-2-RHDT B HDR to FWH26: Reheater Drain Tank Header Downstream of Reheater 22B and 23B Inlet 2-MSD-170 Text19: 10 9321-F-2023 M PEPSE MSD49C-1-RHDT B HDR to FWH26: "B" Reheater Drain Tank Header to #26 FWHs 2-MSD-171 Text19: 10 9321-F-2023 M PEPSE MSD49C-3-RHDT B HDR: "B" Reheater Drain Tank Header to FWH 26A and 26B 2-MSD-172 Text19: 6 9321-F-2023 M PEPSE MSD49C-5-RHDT B HDR to FWH26A: "B" Reheater Drain Tank Header to FWH 26A 2-MSD-173 Text19: 6 9321-F-2023 M PEPSE MSD49C-4-RHDT B HDR to FWH26B: "B" Reheater Drain Tank Header to FWH 26B Report No. 0700.104-02, Appendix C, Revision 2 Page C-71 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section A: CHECWORKS Model Lines 2-MSD-02: Reheater Drains to #26 Feedwater Heaters and Condensers Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-MSD-174 6 9321-F-2023 M PEPSE MSD49C-2-RHDT B HDR to FWH26C: "B" Reheater Drain Tank Header to FWH 26C Section B: SNM Program Lines 2-MSD-01: Moisture Separator Drains to the Heater Drain Tank and Drains Collecting Tank Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MSD-097 2.5 9321-F-2023 S NC Operating conditions unknown. PEPSE MS Drain Tank 21A vent to MSR Text19:

2-MSD-098 2.5 9321-F-2023 S NC Operating conditions unknown. PEPSE MS Drain Tank 22A vent to MSR Text19:

2-MSD-099 2.5 9321-F-2023 S NC Operating conditions unknown. PEPSE MS Drain Tank 23A vent to MSR Text19:

2-MSD-100 2.5 9321-F-2023 S NC Operating conditions unknown. PEPSE MS Drain Tank 21B vent to MSR Text19:

2-MSD-101 2.5 9321-F-2023 S NC Operating conditions unknown. PEPSE MS Drain Tank 22B vent to MSR Text19:

2-MSD-102 2.5 9321-F-2023 S NC Operating conditions unknown. PEPSE MS Drain Tank 23B vent to MSR Text19:

2-MSD-103-A 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD33A-1-MSDT 21A to HDT: MS components in this line. Drain Tank 21A Nozzle to Heater Drain Tank 2-MSD-103-C Text19: 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD33A-1-MSDT 21A to HDT:

components in this line. Heater Drain Tank Nozzle from MS Drain Tank 21A 2-MSD-104-A Text19: 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD34A-1-MSDT 22A to HDT: MS components in this line. Drain Tank 22A Nozzle to Heater Drain Tank 2-MSD-104-C Text19: 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD34A-1-MSDT 22A to HDT:

components in this line. Heater Drain Tank Nozzle from MS Drain Tank 22A Report No. 0700.104-02, Appendix C, Revision 2 Page C-72 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section B: SNM Program Lines 2-MSD-01: Moisture Separator Drains to the Heater Drain Tank and Drains Collecting Tank Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MSD-105-A 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD35A-1-MSDT 23A to HDT: MS components in this line. Drain Tank 23A Nozzle to Heater Drain Tank 2-MSD-105-C Text19: 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD35A-1-MSDT 23A to HDT:

components in this line. Heater Drain Tank Nozzle from MS Drain Tank 23A 2-MSD-106-A Text19: 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD36A-1-MSDT 21B to HDT: MS components in this line. Drain Tank 21B Nozzle to Heater Drain Tank 2-MSD-106-C Text19: 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD36A-1-MSDT 21B to HDT:

components in this line. Heater Drain Tank Nozzle from MS Drain Tank 21B 2-MSD-107-A Text19: 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD37A-1-MSDT 22B to HDT: MS components in this line. Drain Tank 22B Nozzle to Heater Drain Tank Text19:

2-MSD-107-C 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD37A-1-MSDT 22B to HDT:

components in this line. Heater Drain Tank Nozzle from MS Drain Tank 22B Text19:

2-MSD-108-A 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD38A-1-MSDT 23B to HDT: MS components in this line. Drain Tank 23B Nozzle to Heater Drain Tank 2-MSD-108-C Text19: 6 9321-F-2023 S NL The nozzles are the only susceptible SFA Model MSD38A-1-MSDT 23B to HDT:

components in this line. Heater Drain Tank Nozzle from MS Drain Tank 23B 2-MSD-02: Reheater Drains to #26 Feedwater Heaters and Condensers Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MSD-145 2.5 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater Drain Tank 21A Vent to MSR Report No. 0700.104-02, Appendix C, Revision 2 Page C-73 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section B: SNM Program Lines 2-MSD-02: Reheater Drains to #26 Feedwater Heaters and Condensers Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MSD-146 2.5 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater Drain Tank 22A Vent to MSR 2-MSD-147 Text19: 2.5 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater Drain Tank 23A Vent to MSR 2-MSD-148 Text19: 2.5 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater Drain Tank 21B Vent to MSR 2-MSD-149 Text19: 2.5 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater Drain Tank 22B Vent to MSR 2-MSD-150 Text19: 2.5 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater Drain Tank 23B Vent to MSR 2-MSD-175 Text19: 8 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater 21A to Condenser 23 Text19:

2-MSD-176 8 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater 22A to Condenser 22 Text19:

2-MSD-177 8 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater 23A to Condenser 23 Text19:

2-MSD-178 6 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater 21B to Condenser 21 Text19:

2-MSD-179 6 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater 22B to Condenser 22 Text19:

2-MSD-180 6 9321-F-2023 S NC Operating conditions unknown. P&ID Reheater 23B to Condenser 21 Section C: Excluded Lines 2-MSD-01: Moisture Separator Drains to the Heater Drain Tank and Drains Collecting Tank Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MSD-103-B 6 9321-F-2023 E EM This line has been clad with Stainless Steel. SFA Model MSD33A-1-MSDT 21A to HDT: MS Drain Tank 21A Drain to Heater Drain Tank Report No. 0700.104-02, Appendix C, Revision 2 Page C-74 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Separator Reheater Drains (MSD), Unit 2 Section C: Excluded Lines 2-MSD-01: Moisture Separator Drains to the Heater Drain Tank and Drains Collecting Tank Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MSD-104-B 6 9321-F-2023 E EM This line has been clad with Stainless Steel. SFA Model MSD34A-1-MSDT 22A to HDT: MS Drain Tank 22A Drain to Heater Drain Tank 2-MSD-105-B Text19: 6 9321-F-2023 E EM This line has been clad with Stainless Steel. SFA Model MSD35A-1-MSDT 23A to HDT: MS Drain Tank 23A Drain to Heater Drain Tank 2-MSD-106-B Text19: 6 9321-F-2023 E EM This line has been clad with Stainless Steel. SFA Model MSD36A-1-MSDT 21B to HDT: MS Drain Tank 21B Drain to Heater Drain Tank 2-MSD-107-B Text19: 6 9321-F-2023 E EM This line has been clad with Stainless Steel. SFA Model MSD37A-1-MSDT 22B to HDT: MS Drain Tank 22B Drain to Heater Drain Tank 2-MSD-108-B Text19: 6 9321-F-2023 E EM This line has been clad with Stainless Steel. SFA Model MSD38A-1-MSDT 23B to HDT: MS Drain Tank 23B Drain to Heater Drain Tank Text19:

2-MSD-109 6 9321-F-2023 E EI Line operates less than 2% of the time CSI Document MS Drain Tank 21A Drain to Drains 0700.104.C.008 Collecting Tank 2-MSD-110 Text19: 6 9321-F-2023 E EI Line operates less than 2% of the time CSI Document MS Drain Tank 22A Drain to Drains 0700.104.C.008 Collecting Tank 2-MSD-111 Text19: 6 9321-F-2023 E EI Line operates less than 2% of the time CSI Document MS Drain Tank 23A Drain to Drains 0700.104.C.008 Collecting Tank 2-MSD-112 Text19: 6 9321-F-2023 E EI Line operates less than 2% of the time CSI Document MS Drain Tank 21B Drain to Drains 0700.104.C.008 Collecting Tank 2-MSD-113 Text19: 6 9321-F-2023 E EI Line operates less than 2% of the time CSI Document MS Drain Tank 22B Drain to Drains 0700.104.C.008 Collecting Tank 2-MSD-114 Text19: 6 9321-F-2023 E EI Line operates less than 2% of the time CSI Document MS Drain Tank 23B Drain to Drains 0700.104.C.008 Collecting Tank Report No. 0700.104-02, Appendix C, Revision 2 Page C-75 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section B: SNM Program Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-019-A 12 A227780 S NC Flow Conditions Unknown PEPSE Crossunder Steam Trap to Condenser 21 2-MST-020-A Text19: 12 A227780 S NC Flow Conditions Unknown PEPSE Crossunder Steam Trap to Condenser 21 2-MST-021-A Text19: 12 A227780 S NC Flow Conditions Unknown PEPSE Crossunder Steam Trap to Condenser 22 2-MST-022-A Text19: 12 A227780 S NC Flow Conditions Unknown PEPSE Crossunder Steam Trap to Condenser 22 2-MST-023-A Text19: 12 A227780 S NC Flow Conditions Unknown PEPSE Crossunder Steam Trap to Condenser 23 2-MST-024-A Text19: 12 A227780 S NC Flow Conditions Unknown PEPSE Crossunder Steam Trap to Condenser 23 2-MST-080-A Text19: 1.5 9321-F-2041 S NS High quality main steam line. PEPSE Main steam to MST-1 Text19:

2-MST-080-B 1.5 9321-F-2041 S NS Operating conditions unknown. P&ID MST-1 to Steam Trap Header Text19:

2-MST-081-A 1.5 9321-F-2041 S NS High quality main steam line. PEPSE Main steam to MST-2 Text19:

2-MST-081-B 1.5 9321-F-2041 S NS Operating conditions unknown. P&ID MST-2 to Steam Trap Header Text19:

2-MST-082-A 1.5 9321-F-2041 S NS High quality main steam line. PEPSE Main steam to MST-3 Text19:

2-MST-082-B 1.5 9321-F-2041 S NS Operating conditions unknown. P&ID MST-3 to Steam Trap Header Text19:

2-MST-083-A 1.5 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from Drain Pot to MST-4 Text19:

2-MST-083-B 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-1-24 US Leakoff to MST-4.

2-MST-083-C Text19: 9321-F-2041 S NS Operating conditions unknown. P&ID MST-4 to Steam Trap Header Text19:

2-MST-084-A 1.25 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-1-21 US Leakoff to MST-5 Report No. 0700.104-02, Appendix C, Revision 2 Page C-76 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section B: SNM Program Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-084-B 1.25 9321-F-2041 S NS Operating conditions unknown. P&ID MST-5 to Steam Trap Header Text19:

2-MST-085-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-2A US Leakoff to MST-6 2-MST-085-B Text19: 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-1-21 DS Leakoff to MST-6 2-MST-085-C Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-6 to Steam Trap Header Text19:

2-MST-086-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-2A DS Leakoff to MST-8 2-MST-086-B Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-8 to Steam Trap Header Text19:

2-MST-087-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-2B DS Leakoff to MST-9 2-MST-087-B Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-9 to Steam Trap Header Text19:

2-MST-088-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-1-22 DS Leakoff to MST-10 2-MST-088-B Text19: 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-2B US Leakoff to MST-10 2-MST-088-C Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-10 to Steam Trap Header Text19:

2-MST-089-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-1-22 US Leakoff to MST-12 2-MST-089-B Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-12 to Steam Trap Header Text19:

2-MST-090-A 1.25 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-1-23 US Leakoff to MST-13 2-MST-090-B Text19: 1.25 9321-F-2041 S NS Operating conditions unknown. P&ID MST-13 to Steam Trap Header Text19:

2-MST-091-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-1-23 DS Leakoff to MST-14 Report No. 0700.104-02, Appendix C, Revision 2 Page C-77 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section B: SNM Program Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-091-B 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-2C US Leakoff to MST-14 2-MST-091-C Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-14 to Steam Trap Header Text19:

2-MST-092-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-2C DS Leakoff to MST-16 2-MST-092-B Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-16 to Steam Trap Header Text19:

2-MST-093-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-1-24 DS Leakoff to MST-18 2-MST-093-B Text19: 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-2D US Leakoff to MST-18 2-MST-093-C Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-18 to Steam Trap Header Text19:

2-MST-094-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam from MS-2D DS Leakoff to MST-20 2-MST-094-B Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-20 to Steam Trap Header Text19:

2-MST-095-A 1.5 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam to MST-21 Text19:

2-MST-095-B 1.5 9321-F-2041 S NS Operating conditions unknown. P&ID MST-21 to Steam Trap Header Text19:

2-MST-096-A 1.5 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam to MST-22 Text19:

2-MST-096-B 1.5 9321-F-2041 S NS Operating conditions unknown. P&ID MST-22 to Steam Trap Header Text19:

2-MST-097-A 1.5 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam to MST-23 Text19:

2-MST-097-B 1.5 9321-F-2041 S NS Operating conditions unknown. P&ID MST-23 to Steam Trap Header Text19:

2-MST-098-A 1 9321-F-2041 S NS DS of nozzle Chrome-Moly PEPSE Exit Nozzle US of Valve MS-90-1 Text19:

2-MST-099-A 1 9321-F-2041 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-25 via Steam Dump Lines Report No. 0700.104-02, Appendix C, Revision 2 Page C-78 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section B: SNM Program Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-099-B 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-25 to Steam Trap Header Text19:

2-MST-100-A 1.25 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-26 via Steam Dump Lines 2-MST-100-B Text19: 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID MST-26 to Steam Trap Header Text19:

2-MST-101-A 1 9321-F-2041 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-27 via Steam Dump Lines 2-MST-101-B Text19: 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-27 to Steam Trap Header Text19:

2-MST-102-A 1.25 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-28 via Steam Dump Lines 2-MST-102-B Text19: 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID MST-28 to Steam Trap Header Text19:

2-MST-103-A 1.25 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-29 via Steam Dump Lines 2-MST-103-B Text19: 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID MST-29 to Steam Trap Header Text19:

2-MST-104-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-30 Text19:

2-MST-104-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-30 to Steam Trap Header Text19:

2-MST-105-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-31 Text19:

2-MST-105-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-31 to Header Text19:

2-MST-105-D 1 9321-F-2042 S NS Operating conditions unknown. P&ID Header to Steam Trap Header Text19:

2-MST-106-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-32 Text19:

2-MST-106-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-32 to Steam Trap Header Text19:

2-MST-107-A 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-33 Text19:

2-MST-107-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-33 to Steam Trap Header Report No. 0700.104-02, Appendix C, Revision 2 Page C-79 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section B: SNM Program Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-108-A 1.25 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-34 Text19:

2-MST-108-B 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID MST-34 to Steam Trap Header Text19:

2-MST-109-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-35 Text19:

2-MST-109-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-35 to Steam Trap Header 2-MST-110-A Text19: 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam to MST-36 Text19:

2-MST-110-B 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-36 to Steam Trap Header Text19:

2-MST-111-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-37 Text19:

2-MST-111-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-37 to Steam Trap Header Text19:

2-MST-112-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-38 Text19:

2-MST-112-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-38 to Steam Trap Header Text19:

2-MST-113-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-39 Text19:

2-MST-113-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-39 to Header Text19:

2-MST-113-D 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID Header to Steam Trap Header Text19:

2-MST-114-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-40 Text19:

2-MST-114-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-40 to Header Text19:

2-MST-115-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Main Steam to MST-41 Text19:

2-MST-115-B 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-41 to Header Text19:

2-MST-116-A 1.25 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-42 via Steam Dump Lines 2-MST-116-B Text19: 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID MST-42 to Steam Trap Header Report No. 0700.104-02, Appendix C, Revision 2 Page C-80 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section B: SNM Program Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-117-A 1.25 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-43 via Steam Dump Lines 2-MST-117-B Text19: 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID MST-43 to Steam Trap Header Text19:

2-MST-118-A 1.25 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-44 via Steam Dump Lines 2-MST-118-B Text19: 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID MST-44 to Steam Trap Header Text19:

2-MST-119-A 1.25 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-45 via Steam Dump Lines 2-MST-119-B Text19: 1.25 9321-F-2042 S NS Operating conditions unknown. P&ID MST-45 to Steam Trap Header Text19:

2-MST-120-A 1 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-46 via Steam Dump Lines 2-MST-120-B Text19: 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-46 to Steam Trap Header Text19:

2-MST-121-A 1 9321-F-2042 S NS Pressurized line with flow to steam trap. PEPSE Main Steam to MST-47 via Steam Dump Lines 2-MST-121-B Text19: 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-47 to Steam Trap Header Text19:

2-MST-122-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-48 Text19:

2-MST-122-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-48 to Steam Trap Header Text19:

2-MST-123-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-49 Text19:

2-MST-123-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-49 to Steam Trap Header Text19:

2-MST-124-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-50 Text19:

2-MST-124-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-50 to Steam Trap Header Text19:

2-MST-125-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-51 Text19:

2-MST-125-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-51 to Steam Trap Header Report No. 0700.104-02, Appendix C, Revision 2 Page C-81 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section B: SNM Program Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-126-A 1 9321-F-2042 S NS High quality main steam line. PEPSE Main Steam to MST-52 Text19:

2-MST-126-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-52 to Steam Trap Header Text19:

2-MST-127-A 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-56 Text19:

2-MST-127-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-56 to Steam Trap Header 2-MST-128-A Text19: 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-57 Text19:

2-MST-128-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-57 to Steam Trap Header Text19:

2-MST-129-A 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-58 Text19:

2-MST-129-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-58 to Steam Trap Header Text19:

2-MST-130-A 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-59 Text19:

2-MST-130-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-59 to Steam Trap Header Text19:

2-MST-131-A 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-60 Text19:

2-MST-131-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-60 to Header Text19:

2-MST-132-A 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-61 Text19:

2-MST-132-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-61 to Steam Trap Header Text19:

2-MST-133-A 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-62 Text19:

2-MST-133-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-62 to Steam Trap Header Text19:

2-MST-134-A 1 9321-F-2042 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-63 Text19:

2-MST-134-B 1 9321-F-2042 S NS Operating conditions unknown. P&ID MST-63 to Steam Trap Header Text19:

2-MST-135-A 1 9321-F-2041 S NS High quality main steam line. PEPSE Steam to MST-64 Text19:

2-MST-135-B 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-64 to Header Report No. 0700.104-02, Appendix C, Revision 2 Page C-82 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section B: SNM Program Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-136-A 1 9321-F-2041 S NS Operating conditions unknown. SD No. 18.0 Steam to MST-65 Text19:

2-MST-136-B 1 9321-F-2041 S NS Operating conditions unknown. P&ID MST-65 to Header Text19:

2-MST-193-A 0.75 A227780 S NQ High quality main steam line. PEPSE Main Steam to MST-100 Text19:

2-MST-193-B 0.75 A227780 S NS Operating conditions unknown. P&ID MST-100 to Steam Trap Header Section C: Excluded Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-019-B 10 A227780 E EI SD. 18 states FCV-1206 is closed until air SD No. 18.0 Crossunder Steam Trap Bypass Line is actuated to the operator upon a turbine & LP Turbine Steam Dump trip or loss of electrical loading.

Text19:

2-MST-020-B 10 A227780 E EI SD. 18 states FCV-1207 is closed until air SD No. 18.0 Crossunder Steam Trap Bypass Line is actuated to the operator upon a turbine & LP Turbine Steam Dump trip or loss of electrical loading.

Text19:

2-MST-021-B 10 A227780 E EI SD. 18 states FCV-1208 is closed until air SD No. 18.0 Crossunder Steam Trap Bypass Line is actuated to the operator upon a turbine & LP Turbine Steam Dump trip or loss of electrical loading.

2-MST-022-B Text19: 10 A227780 E EI SD. 18 states FCV-1209 is closed until air SD No. 18.0 Crossunder Steam Trap Bypass Line is actuated to the operator upon a turbine & LP Turbine Steam Dump trip or loss of electrical loading.

2-MST-023-B Text19: 10 A227780 E EI SD. 18 states FCV-1210 is closed until air SD No. 18.0 Crossunder Steam Trap Bypass Line is actuated to the operator upon a turbine & LP Turbine Steam Dump trip or loss of electrical loading.

2-MST-024-B Text19: 10 A227780 E EI SD. 18 states FCV-1211 is closed until air SD No. 18.0 Crossunder Steam Trap Bypass Line is actuated to the operator upon a turbine & LP Turbine Steam Dump trip or loss of electrical loading.

Report No. 0700.104-02, Appendix C, Revision 2 Page C-83 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section C: Excluded Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-073 0.5 9321-F-2041 E EI The Aux. Feed Turbine operates less than SD No. 21.0 Aux. Feed Pump Turbine Drive Drain 2% of the time. via MST-69 2-MST-074 Text19: 0.75 9321-F-2041 E EI The Aux. Feed Turbine operates less than SD No. 21.0 Aux. Feed Pump Turbine Drive Drain 2% of the time. via MST-68 2-MST-075 Text19: 0.75 9321-F-2041 E EI The Aux. Feed Turbine operates less than SD No. 21.0 Aux. Feed Pump Turbine Drive Drain 2% of the time. via MST-67 2-MST-080-C Text19: 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-1 Bypass Line Text19:

2-MST-080-D 1.5 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-1 Bypass Line to Steam Trap Header 2-MST-080-E Text19: 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MS-91A Bypass Line Text19:

2-MST-081-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-2 Bypass Line Text19:

2-MST-081-D 1.5 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-2 Bypass Line to Steam Trap Header 2-MST-081-E Text19: 0.75 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MS-91B Bypass Line Text19:

2-MST-082-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-3 Bypass Line Text19:

2-MST-082-D 1.5 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-3 Bypass Line to Steam Trap Header 2-MST-082-E Text19: 0.75 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MS-91C Bypass Line Text19:

2-MST-083-D 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-4 Bypass Line Text19:

2-MST-083-E 1.5 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-4 Bypass Line to Steam Trap Header 2-MST-083-F Text19: 0.75 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MS-91D Bypass Line Text19:

2-MST-084-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-5 Bypass Line Text19:

2-MST-085-D 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-6 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-84 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section C: Excluded Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-085-E 3 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-6 Drain to Steam Trap Header Text19:

2-MST-086-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-8 Bypass Line Text19:

2-MST-087-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-9 Bypass Line Text19:

2-MST-088-D 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-10 Bypass Line 2-MST-088-E Text19: 1 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-10 Bypass to Steam Trap Header 2-MST-089-C Text19: 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-12 Bypass Line Text19:

2-MST-090-C 1.25 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-13 Bypass Line Text19:

2-MST-091-D 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-14 Bypass Line Text19:

2-MST-091-E 0.5 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-14 Drain to Drain Header Text19:

2-MST-092-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-16 Bypass Line Text19:

2-MST-093-D 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-18 Bypass Line Text19:

2-MST-093-E 1 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-18 Drain to Drain Header Text19:

2-MST-094-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-20 Bypass Line Text19:

2-MST-095-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-21 Bypass Line Text19:

2-MST-096-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-22 Bypass Line Text19:

2-MST-097-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-23 Bypass Line Text19:

2-MST-098 1 9321-F-2041 E EM Piping is CrMo. P&ID MST-24 Steam Trap Line Text19:

2-MST-099-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-25 Bypass Line Text19:

2-MST-100-C 1.25 9321-F-2042 E EI Valve normally closed. P&ID MST-26 Bypass Line Text19:

2-MST-101-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-27 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-85 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section C: Excluded Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-102-C 9321-F-2042 E EI Valve normally closed. P&ID MST-28 Bypass Line Text19:

2-MST-103-C 9321-F-2042 E EI Valve normally closed. P&ID MST-29 Bypass Line Text19:

2-MST-104-C 9321-F-2042 E EI Valve normally closed. P&ID MST-30 Bypass Line Text19:

2-MST-105-C 9321-F-2042 E EI Valve normally closed. P&ID MST-31 Bypass Line 2-MST-106-C Text19: 9321-F-2042 E EI Valve normally closed. P&ID MST-32 Bypass Line Text19:

2-MST-107-C 9321-F-2042 E EI Valve normally closed. P&ID MST-33 Bypass Line Text19:

2-MST-108-C 9321-F-2042 E EI Valve normally closed. P&ID MST-34 Bypass Line Text19:

2-MST-109-C 9321-F-2042 E EI Valve normally closed. P&ID MST-35 Bypass Line Text19:

2-MST-110-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-36 Bypass Line Text19:

2-MST-111-C 9321-F-2042 E EI Valve normally closed. P&ID MST-37 Bypass Line Text19:

2-MST-112-C 9321-F-2042 E EI Valve normally closed. P&ID MST-38 Bypass Line Text19:

2-MST-113-C 9321-F-2042 E EI Valve normally closed. P&ID MST-39 Bypass Line Text19:

2-MST-114-C 9321-F-2042 E EI Valve normally closed. P&ID MST-40 Bypass Line Text19:

2-MST-115-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-41 Bypass Line Text19:

2-MST-116-C 9321-F-2042 E EI Valve normally closed. P&ID MST-42 Bypass Line Text19:

2-MST-117-C 9321-F-2042 E EI Valve normally closed. P&ID MST-43 Bypass Line Text19:

2-MST-118-C 9321-F-2042 E EI Valve normally closed. P&ID MST-44 Bypass Line Text19:

2-MST-119-C 9321-F-2042 E EI Valve normally closed. P&ID MST-45 Bypass Line Text19:

2-MST-120-C 9321-F-2042 E EI Valve normally closed. P&ID MST-46 Bypass Line Text19:

2-MST-121-C 9321-F-2042 E EI Valve normally closed. P&ID MST-47 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-86 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section C: Excluded Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-122-C 9321-F-2042 E EI Valve normally closed. P&ID MST-48 Bypass Line Text19:

2-MST-123-C 9321-F-2042 E EI Valve normally closed. P&ID MST-49 Bypass Line Text19:

2-MST-124-C 9321-F-2042 E EI Valve normally closed. P&ID MST-50 Bypass Line Text19:

2-MST-125-C 9321-F-2042 E EI Valve normally closed. P&ID MST-51 Bypass Line 2-MST-126-C Text19: 9321-F-2042 E EI Valve normally closed. P&ID MST-52 Bypass Line Text19:

2-MST-127-C 9321-F-2042 E EI Valve normally closed. P&ID MST-56 Bypass Line Text19:

2-MST-128-C 9321-F-2042 E EI Valve normally closed. P&ID MST-57 Bypass Line Text19:

2-MST-129-C 9321-F-2042 E EI Valve normally closed. P&ID MST-58 Bypass Line Text19:

2-MST-130-C 9321-F-2042 E EI Valve normally closed. P&ID MST-59 Bypass Line Text19:

2-MST-131-C 9321-F-2042 E EI Valve normally closed. P&ID MST-60 Bypass Line Text19:

2-MST-132-C 9321-F-2042 E EI Valve normally closed. P&ID MST-61 Bypass Line Text19:

2-MST-133-C 9321-F-2042 E EI Valve normally closed. P&ID MST-62 Bypass Line Text19:

2-MST-134-C 9321-F-2042 E EI Valve normally closed. P&ID MST-63 Bypass Line Text19:

2-MST-135-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-64 Bypass Line Text19:

2-MST-136-C 9321-F-2041 E EI Valve shown closed on P&ID. P&ID MST-65 Bypass Line Text19:

2-MST-137 1 9321-F-2041 E ER Scavenging steam piping removed from P&ID MST-66 Lines service.

2-MST-138 Text19: 3 9321-F-2041 E EI All feeding valves shown normally closed P&ID Main Steam Trap Drain and Bypass on P&ID Header.

2-MST-139 Text19: 4 9321-F-2041, 9321-F-2042 E EM Line replaced with Stainless Steel FAC Program Plan Main Steam Trap Main Header to Supplement Drains Collecting Tank.

Report No. 0700.104-02, Appendix C, Revision 2 Page C-87 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Main Steam Traps (MST), Unit 2 Section C: Excluded Lines 2-MST-01: Steam Trap Lines from the Main Steam System Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-MST-140 2 9321-F-2042 E EM Line replaced with Stainless Steel FAC Program Plan Main Steam Traps Header to Main Supplement Header 2-MST-141 Text19: 2 9321-F-2042 E EM Line replaced with Stainless Steel FAC Program Plan Main Steam Traps Header to Main Supplement Header 2-MST-142 Text19: 4 9321-F-2042 E EI Valve shown closed on P&ID. P&ID Main Steam Traps Main Header Drain to Discharge Tunnel 2-MST-196 Text19: 0.75 A227780 E EI Valve shown closed on P&ID. P&ID MST-100 Bypass via MS-1144 Report No. 0700.104-02, Appendix C, Revision 2 Page C-88 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Preseparator Drains (PD), Unit 2 Section A: CHECWORKS Model Lines 2-PD-01: Moisture Preseparator Drain Lines Size Sus.

Line Number (in.) P&ID No. Cat. Comments Reference Line Description Text19:

2-PD-001 20 A228272 M PEPSE Moisture Preseparator "A" to Separating Tank A 2-PD-002 Text19: 20 A228272 M PEPSE Moisture Preseparator "B" to Separating Tank A 2-PD-003 Text19: 20 A228272 M PEPSE Moisture Preseparator "C" to Separating Tank B 2-PD-004 Text19: 20 A228272 M PEPSE Moisture Preseparator "D" to Separating Tank B 2-PD-011 Text19: 10 A228272 M PEPSE Separating Tank A Drain to Control Valves 2-PD-012 Text19: 10 A228272 M PEPSE Separating Tank B Drain to Control Valves 2-PD-013 Text19: 10 A228272 M PEPSE Separating Tank A to LCV 5198 Text19:

2-PD-014 10 A228272 M PEPSE Separating Tank A to LCV 5199 Text19:

2-PD-015 10 A228272 M PEPSE Separating Tank B to LCV 5205 Text19:

2-PD-016 10 A228272 M PEPSE Separating Tank B to LCV 5206 Text19:

2-PD-017 10 A228272 M PEPSE Separating Tank A control valves to Heater Drain Tank 2-PD-018 Text19: 10 A228272 M PEPSE Separating Tank B control valves to Heater Drain Tank Report No. 0700.104-02, Appendix C, Revision 2 Page C-89 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Moisture Preseparator Drains (PD), Unit 2 Section B: SNM Program Lines 2-PD-01: Moisture Preseparator Drain Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-PD-005 3 A228272 S NC Flow Rate unknown. PEPSE Moisture Preseparator "A" to 20" Line Text19:

2-PD-006 3 A228272 S NC Flow Rate unknown. PEPSE Moisture Preseparator "B" to 20" Line Text19:

2-PD-007 3 A228272 S NC Flow Rate unknown. PEPSE Moisture Preseparator "C" to 20" Line Text19:

2-PD-008 3 A228272 S NC Flow Rate unknown. PEPSE Moisture Preseparator "D" to 20" Line 2-PD-009-A Text19: 20 A228272 S NL The nozzle is the only susceptible SFA Model ES7A-1-SEP TKA VNT to FWH25:

component in this line. Separating Tank A Nozzle to Extraction Steam Header 2-PD-010-A Text19: 20 A228272 S NL The nozzle is the only susceptible SFA Model ES7A-2-SEP TKB VNT to FWH25:

component in this line. Separating Tank B Nozzle to Extraction Steam Header Section C: Excluded Lines 2-PD-01: Moisture Preseparator Drain Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-PD-009-B 20 A228272 E EM This line was replaced with stainless steel SFA Model ES7A-1-SEP TKA VNT to FWH25:

in RFO13. Separating Tank A to Extraction Steam Header 2-PD-010-B Text19: 20 A228272 E EM This line was replaced with stainless steel SFA Model ES7A-2-SEP TKB VNT to FWH25:

in RFO13. Separating Tank B to Extraction Steam Header 2-PD-019 Text19: 1 A228272 E EI Valve shown closed on P&ID. P&ID 1" Line from Separating Tank B Vent to Extraction header.

Report No. 0700.104-02, Appendix C, Revision 2 Page C-90 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Reheat Steam Traps (RST), Unit 2 Section B: SNM Program Lines 2-RST-01: Reheat Steam Trap Lines Downstream of Reheater Steam Traps Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-RST-001 0.75 9321-H-2024 S NS Operating conditions unknown. PEPSE RST-1 to BFP Turbine Drip Tank Header 2-RST-002 Text19: 0.75 9321-H-2024 S NS Operating conditions unknown. PEPSE RST-2 to BFP Turbine Drip Tank Header 2-RST-003 Text19: 0.75 9321-H-2024 S NS Operating conditions unknown. PEPSE RST-3 to BFP Turbine Drip Tank Header 2-RST-004 Text19: 2 9321-H-2024 S NS Operating conditions unknown. PEPSE Reheat Steam Trap Header to BFP Turbine Drip Tank Report No. 0700.104-02, Appendix C, Revision 2 Page C-91 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Service Boiler (SB), Unit 2 Section B: SNM Program Lines 2-SB-01: Service Boiler Lines Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-SB-001 6 A227780, A209775 S NC Operating conditions unknown. P&ID Auxiliary Steam from PCV-1015 Text19:

2-SB-004 2 9321-F-2120 S NS Operating conditions unknown. P&ID Steam to Condensate Return, Hot Water Heat Exchangers, and Office Unit Heaters 2-SB-005 Text19: 2 9321-F-2120 S NS Operating conditions unknown. P&ID Steam to Hot Water Heat Exchangers and Office Unit Heaters 2-SB-011 Text19: 1 9321-F-2120 S NS Operating conditions unknown. P&ID Header Drain to AST-35 Text19:

2-SB-012 1.5 9321-F-2120 S NS Operating conditions unknown. P&ID Steam to Office Unit Heaters Text19:

2-SB-015 8 A209775 S NC Operating conditions unknown. P&ID Steam from Aux. Steam Header Text19:

2-SB-016 8 A209775 S NC Operating conditions unknown. P&ID Desuperheater Header Text19:

2-SB-022 2 A209775 S NS Operating conditions unknown. P&ID Steam trap header to Cond. Receiver Text19:

2-SB-023 4 A209775 S NC Operating conditions unknown. P&ID Header to Steam Traps Text19:

2-SB-026 1 A209775 S NS Operating conditions unknown. P&ID Desuperheater Header Text19:

2-SB-030 8 A209775 S NC Operating conditions unknown. P&ID Steam to Desuperheater Text19:

2-SB-039 4 A209775 S NC Operating conditions unknown. P&ID Service Boiler Header to Air Tempering Units 2-SB-042 Text19: 6 9321-F-2021, B193201 S NC Operating conditions unknown. P&ID Line from #10 House Service Boiler Deaerator 2-SB-043 Text19: 1.5 9321-F-2021, B193201 S NS Operating conditions unknown. P&ID Line from #10 House Service Boiler Deaerator Report No. 0700.104-02, Appendix C, Revision 2 Page C-92 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Service Boiler (SB), Unit 2 Section C: Excluded Lines 2-SB-01: Service Boiler Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-SB-010 1 9321-F-2120 E EI Valve shown closed on P&ID. P&ID Cross Tie Between 2-SB-005 and 2-SB-007 2-SB-029 Text19: 0.5 A209775 E EI Operating conditions unknown. P&ID Desuperheater bypass Text19:

2-SB-031 8 A209775 E EI Valve shown closed on P&ID. P&ID PCV-1257 Bypass Text19:

2-SB-034 2 A209775 E EF Low flow to floor drain P&ID Steam to floor drain via UH-575 Text19:

2-SB-040 1 A209775 E EI Valve shown closed on P&ID. P&ID PCV-1252 Bypass Text19:

2-SB-041 2 A209775 E EI Valve shown closed on P&ID. P&ID Steam to UHT-514 Text19:

2-SB-044 1 A209775 E EI Valve shown closed on P&ID. P&ID TCV-1257-B Bypass Line Text19:

2-SB-045 1 A209775 E EI Valve shown closed on P&ID. P&ID TCV-1257-A Bypass Line Text19:

2-SB-046 2 A209775 E EI Valve shown closed on P&ID. P&ID Floor Drain via UH-571 Text19:

2-SB-047 3 A209775 E EI Valve shown closed on P&ID. P&ID Aux. Steam to Condenser Water Box Priming Steam Jet Air Ejectors Report No. 0700.104-02, Appendix C, Revision 2 Page C-93 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 2 Section B: SNM Program Lines 2-UH-01: Condensate Return from Unit Heaters to the Deaerator Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-UH-001 4 A209775, 9321-F-2120 S NC Operating conditions unknown. P&ID Condensate return pumps to #20 House Service Deaerator 2-UH-002 Text19: 4 9321-F-2120, B193201 S NC Operating conditions unknown. P&ID Condensate return to #10 House Service Deaerator 2-UH-003 Text19: 10 A209775 S NC Operating conditions unknown. SD No. 29.01 Desuperheater outlet header to various unit heaters 2-UH-004 Text19: 8 A209775 S NC Operating conditions unknown. SD No. 29.01 Desuperheater outlet steam to Gland Seal Steam Header 2-UH-071 Text19: 6 A209775 S NC Operating conditions unknown. P&ID Unit Heater Drain Header to Condensate Receiver 2-UH-072 Text19: 6 A209775 S NC Operating conditions unknown. P&ID Unit Heater Drain Header to Condensate Receiver 2-UH-073 Text19: 4 A209775 S NC Operating conditions unknown. P&ID Condensate Receiver Vent to Atmosphere 2-UH-074 Text19: 3 A209775 S NC Operating conditions unknown. P&ID Condensate Receiver Drain to Cond.

Return Pump #21 2-UH-075 Text19: 3 A209775 S NC Operating conditions unknown. P&ID Condensate Receiver Drain to Cond.

Return Pump #22 2-UH-077 Text19: 4 A209775 S NC Operating conditions unknown. P&ID Cond. Return Pump #21 Discharge Text19:

2-UH-078 4 A209775 S NC Operating conditions unknown. P&ID Cond. Return Pump #21 Discharge Text19:

2-UH-079 2 B193201 S NS Operating conditions unknown. P&ID Line from #20 House Service Boiler to Service Boiler Deaerator Report No. 0700.104-02, Appendix C, Revision 2 Page C-94 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 2 Section C: Excluded Lines 2-UH-01: Condensate Return from Unit Heaters to the Deaerator Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-UH-054 2 A209775 E EI Valve shown closed on P&ID. P&ID Drain line via UH-1103 Text19:

2-UH-055 2 A209775 E EI Valve shown closed on P&ID. P&ID Steam to and from Dirty and Clean Oil Storage Tanks 2-UH-076 Text19: 1 A209775 E EI Valve shown closed on P&ID. P&ID Condensate Receiver Bottom Drain Text19:

2-UH-080 6 A209775 E EI Valve shown closed on P&ID. P&ID PC-5289 Bypass Line Report No. 0700.104-02, Appendix C, Revision 2 Page C-95 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Return Unit Heater Steam Traps (UHT), Unit 2 Section B: SNM Program Lines 2-UHT-01: Steam Trap Lines from the Condensate Return from Unit Heaters to the Deaerator system Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-UHT-005 1 A209775 S NC Operating conditions unknown. SD No. 29.01 Steam to UHT-510 Text19:

2-UHT-006 1 A209775 S NC Operating conditions unknown. SD No. 29.01 Steam to UHT-511 Text19:

2-UHT-007 2 A209775 S NS Operating conditions unknown. P&ID Steam trap header to Cond. Receiver from UHT-510.

2-UHT-008 Text19: 1 A209775 S NS Operating conditions unknown. P&ID Steam from gland steam supply steam traps 2-UHT-009 Text19: 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 215UHR Text19:

2-UHT-010 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 217UHR Text19:

2-UHT-011 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 29UHR Text19:

2-UHT-012 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 22UHR Text19:

2-UHT-013 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from UHT-2-1 Text19:

2-UHT-014 2 A209775 S NS Operating conditions unknown. Flow P&ID Steam to and from 221UHR direction is unclear and seems to indicate that no outlet exists.

Text19:

2-UHT-015 2 A209775 S NS Operating conditions unknown. Flow P&ID Steam to and from 219UHR direction is unclear and seems to indicate that no outlet exists.

2-UHT-016 Text19: 2 A209775 S NS Operating conditions unknown. Flow P&ID Steam to and from 211UHR direction is unclear and seems to indicate that no outlet exists.

2-UHT-017 Text19: 2 A209775 S NS Operating conditions unknown. Flow P&ID Steam to and from 24UHR direction is unclear and seems to indicate that no outlet exists.

2-UHT-018 Text19: 1 A209775 S NS Operating conditions unknown. Flow P&ID Steam to and from UHT-2-2 direction is unclear and seems to indicate that no outlet exists.

Report No. 0700.104-02, Appendix C, Revision 2 Page C-96 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Return Unit Heater Steam Traps (UHT), Unit 2 Section B: SNM Program Lines 2-UHT-01: Steam Trap Lines from the Condensate Return from Unit Heaters to the Deaerator system Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-UHT-019 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 225UHR Text19:

2-UHT-020 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 224UHR Text19:

2-UHT-021 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 223UHR Text19:

2-UHT-022 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 213UHR 2-UHT-023 Text19: 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 27UHR Text19:

2-UHT-024 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from UHT-1-1 Text19:

2-UHT-024-A 4 A209775 S NC Operating conditions unknown. P&ID Steam to UHT-512 and 513 Text19:

2-UHT-025 1 A209775 S NS Operating conditions unknown. Flow P&ID Steam to and from Oil Preheater direction is unclear and seems to indicate that no outlet exists.

2-UHT-026 Text19: 1 A209775 S NS Operating conditions unknown. Flow P&ID Steam to and from UHT-4-1 direction is unclear and seems to indicate that no outlet exists.

Text19:

2-UHT-027 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 24AUHR Text19:

2-UHT-028 1.5 A209775 S NS Operating conditions unknown. P&ID Steam to and from UHT-2-3 Text19:

2-UHT-029 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 248UHR Text19:

2-UHT-030 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 250UHR Text19:

2-UHT-031 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 249UHR Text19:

2-UHT-032 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 252UHR Text19:

2-UHT-033 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 251UHR Text19:

2-UHT-034 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from UHT-11-3 Text19:

2-UHT-035 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 247UHR Report No. 0700.104-02, Appendix C, Revision 2 Page C-97 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Return Unit Heater Steam Traps (UHT), Unit 2 Section B: SNM Program Lines 2-UHT-01: Steam Trap Lines from the Condensate Return from Unit Heaters to the Deaerator system Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-UHT-036 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 246UHR Text19:

2-UHT-037 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 245UHR Text19:

2-UHT-038 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from UHT-11-2 Text19:

2-UHT-039 2 A209775 S NS Operating conditions unknown. P&ID UHT-511 outlet 2-UHT-040 Text19: 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 214UHR Text19:

2-UHT-041 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 216UHR Text19:

2-UHT-042 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 218UHR Text19:

2-UHT-043 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 220UHR Text19:

2-UHT-044 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 222UHR Text19:

2-UHT-045 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from 260UHR Text19:

2-UHT-046 1 A209775 S NS Operating conditions unknown. P&ID Steam to and from UHT-4-2 Text19:

2-UHT-047 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 21UHR Text19:

2-UHT-048 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 28UHR Text19:

2-UHT-049 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 23UHR Text19:

2-UHT-050 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 210UHR Text19:

2-UHT-051 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 212UHR Text19:

2-UHT-052 2 A209775 S NS Operating conditions unknown. P&ID Steam to and from 25UHR Text19:

2-UHT-053 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to and from UHT-11-1 Text19:

2-UHT-056 1 A209775 S NS Operating conditions unknown. P&ID UHT-513 Discharge Text19:

2-UHT-057 0.5 A209775 S NS Operating conditions unknown. P&ID UHT-512 Discharge Report No. 0700.104-02, Appendix C, Revision 2 Page C-98 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Condensate Return Unit Heater Steam Traps (UHT), Unit 2 Section B: SNM Program Lines 2-UHT-01: Steam Trap Lines from the Condensate Return from Unit Heaters to the Deaerator system Size Sus. Mod.

Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-UHT-060 0.75 A209775 S NS Operating conditions unknown. P&ID 21 Air Tempering Unit Discharge Text19:

2-UHT-061 0.75 A209775 S NS Operating conditions unknown. P&ID 22 Air Tempering Unit Discharge Text19:

2-UHT-062 1 A209775 S NS Operating conditions unknown. P&ID Steam to various unit heaters Text19:

2-UHT-063 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to and from UH-TSC-1 2-UHT-064 Text19: 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to and from 242UHR Text19:

2-UHT-065 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to and from 243UHR Text19:

2-UHT-066 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to and from 244UHR Text19:

2-UHT-067 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to and from UHT-8-246 Text19:

2-UHT-068 0.75 A209775 S NS Operating conditions unknown. P&ID Steam to and from 253UHR Text19:

2-UHT-069 2 A209775 S NS Operating conditions unknown. P&ID Unit Heater Drain to Discharge Tunnel Text19:

2-UHT-089 0.75 B227209 S NS Operating conditions unknown. P&ID Steam to and from UH-1020 Text19:

2-UHT-090 0.75 B227209 S NS Operating conditions unknown. P&ID Steam to and from UH-1019 Text19:

2-UHT-092 0.75 B227209 S NS Operating conditions unknown. P&ID Steam to and from UH-1021 Section C: Excluded Lines 2-UHT-01: Steam Trap Lines from the Condensate Return from Unit Heaters to the Deaerator system Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-UHT-070 0.75 A209775 E ER Pipe capped upstream of trap. P&ID Line to and from UHT-3-2 Report No. 0700.104-02, Appendix C, Revision 2 Page C-99 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

MSR Vent Chamber Discharge (VCD), Unit 2 Section C: Excluded Lines 2-VCD-01: Moisture Separator Reheater Vent Chamber Discharge Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-VCD-001 3 A209847 E EM Piping replaced with SS. Previous SSE MSR 21A Vent Chamber Discharge Text19:

2-VCD-002 3 A209847 E EM Piping replaced with SS. Previous SSE MSR 22A Vent Chamber Discharge Text19:

2-VCD-003 3 A209847 E EM Piping replaced with SS. Previous SSE MSR 23A Vent Chamber Discharge Text19:

2-VCD-004 3 A209847 E EM Piping replaced with SS. Previous SSE MSR 21B Vent Chamber Discharge 2-VCD-005 Text19: 3 A209847 E EM Piping replaced with SS. Previous SSE MSR 22B Vent Chamber Discharge Text19:

2-VCD-006 3 A209847 E EM Piping replaced with SS. Previous SSE MSR 23B Vent Chamber Discharge Text19:

2-VCD-007 4 A209847 E EM Stainless Steel Piping P&ID Vent Chamber Discharge Header to FWH 26A 2-VCD-008 Text19: 4 A209847 E EM Stainless Steel Piping P&ID Vent Chamber Discharge Header to FWH 26B 2-VCD-009 Text19: 4 A209847 E EM Stainless Steel Piping P&ID Vent Chamber Discharge Header to FWH 26C 2-VCD-010-A Text19: 3 A209847 E EM Stainless Steel Piping P&ID, Replacement History MSR 21A VCD through HCV-5067B Text19:

2-VCD-010-B 3 A209847 E EM Piping replaced with CrMo. P&ID MSR 21A VCD downstream of HCV-5067B 2-VCD-011-A Text19: 3 A209847 E EM Stainless Steel Piping P&ID, Replacement History MSR 22A VCD through HCV-5069B Text19:

2-VCD-011-B 3 A209847 E EM Piping replaced with CrMo. P&ID MSR 22A VCD downstream of HCV-5069B 2-VCD-012-A Text19: 3 A209847 E EM Stainless Steel Piping P&ID, Replacement History MSR 23A VCD through HCV-5071B Text19:

2-VCD-012-B 3 A209847 E EM Piping replaced with CrMo. P&ID MSR 23A VCD downstream of HCV-5071B 2-VCD-013-A Text19: 3 A209847 E EM Stainless Steel Piping P&ID, Replacement History MSR 21B VCD through HCV-5068B Text19:

2-VCD-013-B 3 A209847 E EM Piping replaced with CrMo. P&ID MSR 21B VCD downstream of HCV-5068B Report No. 0700.104-02, Appendix C, Revision 2 Page C-100 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

MSR Vent Chamber Discharge (VCD), Unit 2 Section C: Excluded Lines 2-VCD-01: Moisture Separator Reheater Vent Chamber Discharge Lines Size Sus. FAC Line Number (in.) P&ID No. Cat. Ex. Crit. Comments Reference Line Description Text19:

2-VCD-014-A 3 A209847 E EM Stainless Steel Piping P&ID, Replacement History MSR 22B VCD through HCV-5070B Text19:

2-VCD-014-B 3 A209847 E EM Piping replaced with CrMo. P&ID MSR 22B VCD downstream of HCV-5070B 2-VCD-015-A Text19: 3 A209847 E EM Stainless Steel Piping P&ID, Replacement History MSR 23B VCD through HCV-5072B Text19:

2-VCD-015-B 3 A209847 E EM Piping replaced with CrMo. P&ID MSR 23B VCD downstream of HCV-5072B Report No. 0700.104-02, Appendix C, Revision 2 Page C-101 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Susceptibility Category (Sus. Cat.) Legend:

M CHECWORKS Modeled S Susceptible, not modeled E Excluded from the FAC program (non-susceptible)

Model Exclusion Criteria (Mod. Ex. Crit.) Legend:

NC Not modeled due to unknown or varying operating Conditions NL Not to be modeled due to Localized FAC susceptibility NM Non-Modelable due to conditions outside CHECWORKS Modeling capabilities NQ Not to be modeled due to high steam Quality, CHECWORKS predictions are of little value NS Non-modelable due to Socket-welded fittings NV Not to be modeled because line is Visually inspected FAC Exclusion Criteria (FAC Ex. Crit.) Legend:

EC Excluded due to Combination of infrequent op above temp threshold EF Excluded due to low or no Flow EI Excluded due to Infrequent operation EM Excluded due to FAC-resistant Material EO Excluded due to high dissolved Oxygen content EP Exluded, does not contain Piping EQ Excluded due to high steam Quality ER Excluded, Removed from service and "cut" and "capped" ET Excluded due to operating Temperature (single phase, < 200 deg F)

EW Excluded because system, subsytem, or line is non-Water Report No. 0700.104-02, Appendix C, Revision 2 Page C-102 of 102

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Appendix D Revision History Report No. 0700.104-02, Appendix D, Revision 2 Page D-1 of 4

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Revision 0 Initial Issue of document.

Revision 1 Systems, subsystem names, and line names were updated to incorporate the new system list.

Revision 2 SSE was updated to incorporate line replacements. Tables D.1, D.2, and D.3 below detail the changes:

Table D.1 System Changes

^E  Z

MSR Vent Chamber ^ŽŽŽ Z

Discharge  ,Ž

Table D.2 Subsystem Changes

^

 Z

E

^ŽŽŽ 2-5EX-03 ^&



^ŽŽŽ Z

2-VCD-01

 ,Ž

Table D.3 Line Changes

>E  Z

^ŽyyŽDŽ

y ^&

Ž^ŽŽ

^ŽyyŽDŽ

y ^&

Ž^ŽŽ

y >ŽŽŽ ^&

y >ŽŽŽ ^&

y >ŽŽŽ ^&

y >ŽŽŽ ^&

y >ŽŽŽ ^&

>ŽŽŽZ

y ^&

Žy

y ŽŽ ^&

Report No. 0700.104-02, Appendix D, Revision 2 Page D-2 of 4

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

>E  Z

>ŽŽŽZ

y ^&

Žy

y ŽŽ ^&

y >ŽŽŽ ^&

y >ŽŽŽ ^&

y >ŽŽŽ ^&

>ŽŽŽZ

y ^&

Žy

y ŽŽ ^&

y >ŽŽŽ ^&

>ŽŽŽZ

y ^&

Žy

y ŽŽ ^&

y >ŽŽŽ ^&

>ŽŽŽZ

y ^&

Žy

y ŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

D^ >ŽŽŽ ^&

>ŽŽŽZ

D^ ^&

ŽD^

D^ ŽŽ ^&

D^ ŽŽ ^&

>ŽŽŽZ

D^ ^&

ŽD^

D^ ŽŽ ^&

D^ ŽŽ ^&

>ŽŽŽZ

D^ ^&

ŽD^

Report No. 0700.104-02, Appendix D, Revision 2 Page D-3 of 4

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

>E  Z

D^ ŽŽ ^&

D^ ŽŽ ^&

>ŽŽŽZ

D^ ^&

ŽD^

D^ ŽŽ ^&

D^ ŽŽ ^&

>ŽŽŽZ

D^ ^&

ŽD^

D^ ŽŽ ^&

D^ ŽŽ ^&

>ŽŽŽZ

D^ ^&

ŽD^

D^ ŽŽ ^&

D^ ŽŽ ^&

>ŽŽŽZ

W ^&

ŽW

W ŽŽ ^&

>ŽŽŽZ

W ^&

ŽW

W ŽŽ ^&

Report No. 0700.104-02, Appendix D, Revision 2 Page D-4 of 4

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Attachment A Industry FAC Experience Table Report No. 0700.104-02, Attachment A, Revision 2 Page Attach A-1 of 6

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Industry experience is an important factor in the identification of systems, subsystems, and lines susceptible to Flow-Accelerated Corrosion (FAC). A table of important industry events and their applicability to Indian Point 2 was compiled using the following sources:

  • Recommendations for an Effective Flow-Accelerated Corrosion Program, EPRI NSAC 202L-R3, 2006.
  • EPRI, Flow-Accelerated Corrosion in Power Plants, B. Chexal et al, EPRI TR-106611-R1, 1998.
  • CHUG Plant Experience Database, Revision 2, December 1995.
  • 26th CHUG Meeting Presentation by Jeff Horowitz "Review and Lessons Learned from Historical FAC Failures".
  • 31st CHUG Meeting Presentation by Aaron Kelley "Unit 1 #2 LP Heater ES Nozzles".
  • 32th CHUG Meeting Presentation by Doug Munson "Update on Mihama-3".
  • 33rd CHUG Meeting Presentation by Aaron Kelley "Results of L2R10 Inspections at LaSalle Unit 2".
  • 33rd CHUG Meeting Presentation by Whit Gallman "Unisolable Steam Leak Downstream of Valve 2HM-23".
  • CHUG Conference Meeting Minutes, FAC Experience Reports, and Presentations.
  • FACnet Email Message Archive.
  • Secondary Pipe Rupture (9 August 2004, Mihama Unit 3, Kansai EPC), WANO EAR TYO 04-013, October 8, 2004.
  • Information Notice 82-2: Failures in Turbine Exhaust Lines, U.S. Nuclear Regulatory Commission (NRC), July 9, 1982.
  • Information Notice 86-106: Feedwater Line Break, U.S. Nuclear Regulatory Commission (NRC), December 16, 1986.
  • Information Notice 86-106, Supplement 1: Feedwater Line Break, U.S. Nuclear Regulatory Commission (NRC), February 13, 1987.
  • Information Notice 86-106, Supplement 2: Feedwater Line Break, U.S. Nuclear Regulatory Commission (NRC), March 18, 1987.
  • NRC Bulletin No. 87-01: Thinning of Pipe Walls in Nuclear Power Plants, U.S.

Nuclear Regulatory Commission (NRC), July 9, 1987.

Nuclear Regulatory Commission (NRC), August 4, 1987.

April 22, 1988.

Report No. 0700.104-02, Attachment A, Revision 2 Page Attach A-2 of 6

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

  • Information Notice 86-106, Supplement 3: Feedwater Line Break, U.S. Nuclear Regulatory Commission (NRC), November 10, 1988.
  • Erosion/Corrosion-Induced Pipe Wall Thinning, Generic Letter 89-08, U.S. Nuclear Regulatory Commission (NRC), May 2, 1989.
  • Investigation into Flow-Accelerated Corrosion at Low Temperatures, Document 1015070, Electric Power Research Institute (EPRI), November 2007.
  • Flow-Accelerated Corrosion - The Entrance Effect, Document 1015072, Electric Power Research Institute (EPRI), November 2007.
  • Erosive Attack, Technical Update 1015071, Electric Power Research Institute (EPRI),

November 2007.

Report No. 0700.104-02, Attachment A, Revision 2 Page Attach A-3 of 6

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Item Plant System Location/Area Plant Year Notes Number Type Downstream of Flow BWR, Failures reported in piping immediately downstream of orifices and flow 1 All Orifices and Flow Meters Many PWR meters. This is a generic issue applicable to all systems.

Downstream of Control Many plants reported instances of FAC degradation and some Valves (level control Millstone 2&3, BWR, significant failures (Millstone 2&3, Surry). This is a generic issue 2 All valves) Surry PWR applicable to all systems.

Leaking valves and steam traps may be found by plant thermal performance evaluation. Downstream piping may experience severe Downstream of Leaking conditions and may have been excluded from FAC Program due to 3 All Valves and Steam Traps Many All infrequent operation. This is a generic issue applicable to all systems.

Extensive industry exp in miscellaneous drain headers from steam Miscellaneous Drains to drains to the condenser. In addition to FAC, these headers are Common Headers into susceptible to liquid impingement erosion and/or flashing/cavitation as 4 All Condenser Many All explained in EPRI Erosive Attack Technical Update 1015071.

Pipe rupture at Surry Unit 2. Occurred in 18" OD, Tnom = 0.5" elbow upstream of feedwater pumps (first elbow off header to FWP). T=374 5 Condensate Feedwater Pump Suction Surry Unit 2 PWR 1986 deg F.

Condensate (between 4th highest pressure Failure in condensate system at Mihama. Occurred in 22" pipe 6 Condensate FWH and dearator) Mihama PWR 2004 downstream of flow measuring orifice. 284 deg F Oconee, Vermont Failures in steam lines due to FAC. All extraction stages carrying wet Extraction Extraction Steam (All Yankee, steam are susceptible to FAC. In general, all plants have experience Steam (or stages carrying wet Trojan, Zion, BWR, with thinning in the extraction steam system (plants listed appeared in 7 Bleed Steam) steam) Browns Ferry PWR 1982 NRC Information Notice 82-22)

Extraction Steam (or Fishmouth failure at ANO 2. Occurred in 14" OD, 2-phase flow. Failure 8 Bleed Steam) HP Extraction 2nd Stage ANO 2 PWR 1989 at Zion (1988), Oconee (1982).

Extraction Steam (or Fishmouth failure at Sequoyah 2. Occurred in 10" straight pipe 9 Bleed Steam) HP Extraction Sequoyah 2 PWR 1993 downstream of tee in HP extraction.

Report No. 0700.104-02, Attachment A, Revision 2 Page Attach A-4 of 6

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Item Plant System Location/Area Plant Year Notes Number Type Fishmouth rupture at Fort Calhoun in third elbow (12" bent pipe R/D =

Extraction 5) downstream of turbine in extraction steam system. Section of Steam (or upstream piping had been replaced in 1985 due to FAC; this 10 Bleed Steam) Extraction (4th Stage) Fort Calhoun PWR 1997 downstream section was not inspected. 411 deg F, 2 phase Failure of LP Heater inlet nozzles (carbon steel nozzles in Cr-Mo line).

Also through-walls on carbon steel pup piece on bellows assembly in Extraction Extraction (carbon steel Cr-Mo line (bellows was stainless steel). The conclusion from these Steam (or components in Cr- events is that to be non-susceptible to FAC the entire line (incl. nozzles, 11 Bleed Steam) Mo/Stainless/etc line) LaSalle BWR 2004 valves, pup pieces, etc.) must be of FAC-resistant material.

Feedwater Pump Outlet Thinning caused by FAC at Oyster Creek in 1978. Cracking observed 12 Feedwater & DS of CVs Oyster Creek BWR 1978 at feedwater pump outlet and downstream of flow/level control valves.

Feedwater Pump Pipe rupture at Navajo. Occurred in 10" OD, Tnom = 0.365" elbow 13 Feedwater Discharge Navajo Fossil 1982 downstream of boiler feed pump. T=360 deg F.

Extensive thinning to min acceptable wall thickness at Trojan in safety Final Feedwater (Safety- related feedwater (and non-safety related). High velocity and large 14 Feedwater Related) Trojan PWR 1987 counterbores exacerbated FAC.

Feedwater at Flow Rupture at Loviisa. Occurred in feedwater system at flow measurement 15 Feedwater Measurement Orifice Loviisa PWR 1990 orifice.

Instantaneous double-ended pipe break at Pleasant Prairie. Occurred Pleasant in 12" feedwater line downstream of valve station and upstream of 16 Feedwater Feedwater Prairie Fossil 1995 economizer and boiler.

San Onofre Serious thinning at San Onofre and Diablo Canyon (could be valve Control Valve Bypass and Diablo BWR, leakage, left open at full power-high velocity, or infrequent but severe 17 Feedwater Lines Canyon PWR conditions).

Feedwater Pump Min Flow (Recirculation) Feedwater pump min flow lines to condenser have experienced 18 Feedwater Lines Many All significant degradation.

Heater Drain Pump Failure at Millstone 2. Occurred in 8" recirc line from heater drain pump 19 Heater Drain Recirc (Bypass) Millstone 2 PWR 1995 to heater drain tank. Line operated during startup only (0-30% power).

Report No. 0700.104-02, Attachment A, Revision 2 Page Attach A-5 of 6

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Item Plant System Location/Area Plant Year Notes Number Type ANO, Kewaunee, McGuire, Extensive FAC-induced thinning found throughout this system at many Feedwater Heater Vents Point Beach, PWR, plants. Some plants have replaced the entire system with non-20 Heater Vents to Condenser Waterford BWR susceptible material (stainless steel or Cr-Mo).

Cross-Under Piping (also North Anna, called Cold Reheat, HP ANO, Point Significant FAC in cross-under piping at North Anna, ANO, and Point Turbine to Moisture Beach, D.C. BWR, Beach. Some plants have small amounts of Cu/Cr in this lines which 21 Main Steam Separator) Cook PWR significantly reduces FAC.

Moisture Catastrophic failure at Millstone 3. Occurred in 6" OD Moisture Sep.

Separator Moisture Separator Drain Drain Tank drain immediately downstream of level CV. 380 deg F, 0%

22 Drain Tank Drain Millstone 3 PWR 1990 quality.

Reheater Reheater Drain Tank Rupture at Millstone 2. Occurred in 8" Reheater Drain Tank drain 23 Drain Drain Millstone 2 PWR 1991 immediately downstream of level CV. 463 deg F, 0% quality.

Reheater First Stage Reheater Failure at Callaway just downstream of long horizontal section in first 24 Drain Drain Callaway PWR 1999 stage reheater drain. 417 deg F, 4.5% quality Moisture Separator Reheater Drain/Vent to Unisolable steam leak occurred in 2" line that vents wet steam from Reheater Drain Tank (Scavenging MSR to drain tank. Flashing contributed to wear (pressure drop caused 25 Drain Steam) McGuire PWR 2005 by "tortuous path" through many fittings in line). 540 deg F, wet steam Some plants have experienced Low-Temperature FAC wear in South Texas deoxygenated, neutral water at about 120ºF as per EPRI Technical Multiple Deoxygenated lines Project, Palo PWR, Report 1015170 Investigation into Flow-Accelerated Corrosion at Low 26 Systems operating at 120ºF Verde, Surry BWR Temperatures.

Diablo Canyon, Pipes made of corrosive material have shown high corrosion rates Multiple Salem, V. C. PWR, downstream of welds connecting non-resistant material to the resistant 27 Systems Multiple Locations Summer BWR material.

Report No. 0700.104-02, Attachment A, Revision 2 Page Attach A-6 of 6

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Attachment B Referenced Correspondence and Communication Report No. 0700.104-02, Attachment B, Revision 2 Page Attach B-1 of 7

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Email from Ryan Doremus (CSI) to Ian Mew (IPEC) regarding a Line Naming Convention, dated 7/27/2009.

Ian, Im close to the point where I will have to start assigning line names for categorization purposes. Since the P&IDs seem to be very good at giving line information (size, pipe class, etc.), I want to propose a simple naming convention that consists of Unit #, System Abbreviation, a sequential number, and if needed a sequential letter that would be used if susceptibility changes within a line.

U-SSS-000-A U = Unit Number SSS = System Abbreviation 000 = Sequential Number A = Section of line that is split for susceptibility.

For example: 2-6EX-003 or 2-BFD-002-A Let me know what you think.

Thank you, Ryan D. Doremus Engineer CSI Technologies, Inc.

(847) 836-3000 x796 rdoremus@csitechnologies.com Report No. 0700.104-02, Attachment B, Revision 2 Page Attach B-2 of 7

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Email from Ian Mew (IPEC) to Ryan Doremus (CSI) regarding responses to information requests, dated 8/10/2009.

Ryan, Answers to item 6, 9 & 10 will be sent shortly.

,DQ'0HZ

IPEC FAC Engineer Phone 914-827-7741

)URP.RXWVDNRV0LFKDHO

6HQW0RQGD\$XJXVW$0

7R0HZ,DQ

&F.RXWVDNRV0LFKDHO

6XEMHFW5(,3(&8QLW66(610,QIRUPDWLRQ5HTXHVW

 /LQHVDFWXDOO\H[LVW7KH\VKRXOGEHLQFOXGHGLQWKH&KHFZRUNVPRGHO 

 8QGHUQRUPDORSHUDWLRQDOO06WUDSE\SDVVHVDUHQRUPDOO\FORVHGXQOHVVWKHWUDSKDVEHHQ

LGHQWLILHGDVGHILFLHQW 

 8QGHUQRUPDORSHUDWLRQOHVVWKDQRIWKHWLPH 

 8QGHUQRUPDORSHUDWLRQOHVVWKDQRIWKHWLPH 

 8QGHUQRUPDORSHUDWLRQOHVVWKDQRIWKHWLPH 

 7DONWR-DPHV3HWHUV &KHPLVWU\6XSHUYLVRU 

 8QGHUQRUPDORSHUDWLRQOHVVWKDQRIWKHWLPH 

 8QGHUQRUPDORSHUDWLRQOHVVWKDQRIWKHWLPH 

 7DONWR-DPHV3HWHUV &KHPLVWU\6XSHUYLVRU 

 7DONWR-DPHV3HWHUV &KHPLVWU\6XSHUYLVRU 



)URP0HZ,DQ

6HQW7KXUVGD\$XJXVW$0

7R.RXWVDNRV0LFKDHO

6XEMHFW):,3(&8QLW66(610,QIRUPDWLRQ5HTXHVW Can you answer Questions 1-10 or point me to a person who can.

,DQ'0HZ

IPEC FAC Engineer Phone 914-827-7741

)URP5\DQ'RUHPXV>PDLOWR5'RUHPXV#FVLWHFKQRORJLHVFRP@

6HQW)ULGD\-XO\30

7R0HZ,DQ

6XEMHFW,3(&8QLW66(610,QIRUPDWLRQ5HTXHVW CSI Document No. 0700.104.C.004

Ian, I completed a cursory review of the SSE/SNM IP2 and have a few pieces of information that would be helpful:

Report No. 0700.104-02, Attachment B, Revision 2 Page Attach B-3 of 7

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

1. Do actual lines exist from the HP Turbine to the Moisture Preseparators or are the Preseparators connected directly to the turbine? If they exist, are they inspected visually or should they be included in the CHECWORKS model?
2. Is it safe to assume that all Main Steam steam trap bypass valves on 9321-F-2041 and 9321-F-2042 are normally closed despite the fact that some are shown open?
3. Does the Feedwater Heater Bypass line (A235307, G-5) operate more or less than 2% of the time?
4. Do the Boiler Feed Pump discharge lines to the Drains Collecting Tank (9321-F-2017, H-6) operate more or less than 2% of the time?
5. Does the 18 HP Feedwater Heater Bypass line (9321-F-2019, F-3) operate more or less than 2%

of the time?

6. Do the lines from the Heater Drain Pump Discharge to the HDP Water Chemistry Monitor (9321-F-2022, A2) operate more or less than 2% of the time?
7. Do the level control lines from the Heater Drain Tank to the Condenser (A235304, A-1 C-1 F-1) operate more or less than 2% of the time?
8. Do the Moisture Separator drains to the Drains Collecting Tank (9321-F-2023, H4) operate more or less than 2% of the time?
9. Do the SG Blowdown lines to the sample coolers (9321-F-2729, D-6) operate more or less than 2% of the time?
10. What is the outlet temperature of the SG Blowdown sample coolers (9321-F-2729, E-6)?

Any information on these would be helpful. Feel free to forward these questions on to system engineers or to send me operating procedures that might answer the questions. To maintain the integrity of the project schedule, we will need these answers by Wednesday, August 5.

In addition to the above, please send the Aux. Steam operating procedures (SOP 29.1.1, 29.1.2, and 29.1.3) and the following drawings:

9321-F-2027 9321-F-2028 9321-F-2033 9321-F-2067 9321-F-2720 9321-F-2722 9321-F-2723 9321-F-2745 9321-F-7020 A205957 B237144 192491 If its possible, I would like to have these drawings and the Aux. Steam OPs by next week, even if they come separately from the questions, to give me time to analyze them. If you have any questions, please feel free to contact me.

Thank you, Ryan D. Doremus Engineer CSI Technologies, Inc.

(847) 836-3000 x796 rdoremus@csitechnologies.com Report No. 0700.104-02, Attachment B, Revision 2 Page Attach B-4 of 7

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Email from Ian Mew (IPEC) to Ryan Doremus (CSI) regarding responses to information requests, dated 8/13/2009.

See Answers below.

,DQ'0HZ

IPEC FAC Engineer Phone 914-827-7741

)URP0HZ,DQ

6HQW0RQGD\$XJXVW$0

7R3HWHUV-DPHV*

6XEMHFW):,3(&8QLW66(610,QIRUPDWLRQ5HTXHVW

Jim, Can you answer the following questions? I need the answer to develop a System Susceptibility Evaluation for the FAC program for IP2.
11. Do the lines from the Heater Drain Pump Discharge to the HDP Water Chemistry Monitor (9321-F-2022, A2) operate more or less than 2% of the time? Yes 1 month a year - all material is SS after the root isolation valve which is less than 1 foot long
12. Do the SG Blowdown lines to the sample coolers (9321-F-2729, D-6) operate more or less than 2% of the time? Sample lines are all SS from the blowdown lines thru the coolers
13. What is the outlet temperature of the SG Blowdown sample coolers (9321-F-2729, E-6)? - from CCW heat exchanger outlet temp is <140F

,DQ'0HZ

IPEC FAC Engineer Phone 914-827-7741

)URP5\DQ'RUHPXV>PDLOWR5'RUHPXV#FVLWHFKQRORJLHVFRP@

6HQW)ULGD\-XO\30

7R0HZ,DQ

6XEMHFW,3(&8QLW66(610,QIRUPDWLRQ5HTXHVW CSI Document No. 0700.104.C.004

Ian, I completed a cursory review of the SSE/SNM IP2 and have a few pieces of information that would be helpful:
14. Do actual lines exist from the HP Turbine to the Moisture Preseparators or are the Preseparators connected directly to the turbine? If they exist, are they inspected visually or should they be included in the CHECWORKS model?
15. Is it safe to assume that all Main Steam steam trap bypass valves on 9321-F-2041 and 9321-F-2042 are normally closed despite the fact that some are shown open?
16. Does the Feedwater Heater Bypass line (A235307, G-5) operate more or less than 2% of the time?
17. Do the Boiler Feed Pump discharge lines to the Drains Collecting Tank (9321-F-2017, H-6) operate more or less than 2% of the time?

Report No. 0700.104-02, Attachment B, Revision 2 Page Attach B-5 of 7

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

18. Does the 18 HP Feedwater Heater Bypass line (9321-F-2019, F-3) operate more or less than 2%

of the time?

19. Do the lines from the Heater Drain Pump Discharge to the HDP Water Chemistry Monitor (9321-F-2022, A2) operate more or less than 2% of the time?
20. Do the level control lines from the Heater Drain Tank to the Condenser (A235304, A-1 C-1 F-1) operate more or less than 2% of the time?
21. Do the Moisture Separator drains to the Drains Collecting Tank (9321-F-2023, H4) operate more or less than 2% of the time?
22. Do the SG Blowdown lines to the sample coolers (9321-F-2729, D-6) operate more or less than 2% of the time?
23. What is the outlet temperature of the SG Blowdown sample coolers (9321-F-2729, E-6)?

Any information on these would be helpful. Feel free to forward these questions on to system engineers or to send me operating procedures that might answer the questions. To maintain the integrity of the project schedule, we will need these answers by Wednesday, August 5.

In addition to the above, please send the Aux. Steam operating procedures (SOP 29.1.1, 29.1.2, and 29.1.3) and the following drawings:

9321-F-2027 9321-F-2028 9321-F-2033 9321-F-2067 9321-F-2720 9321-F-2722 9321-F-2723 9321-F-2745 9321-F-7020 A205957 B237144 192491 If its possible, I would like to have these drawings and the Aux. Steam OPs by next week, even if they come separately from the questions, to give me time to analyze them. If you have any questions, please feel free to contact me.

Thank you, Ryan D. Doremus Engineer CSI Technologies, Inc.

(847) 836-3000 x796 rdoremus@csitechnologies.com Report No. 0700.104-02, Attachment B, Revision 2 Page Attach B-6 of 7

CSI TECHNOLOGIES, INC. Indian Point 2 FAC System Susceptibility Evaluation (SSE)

Email from Brian Trudeau (CSI) to Ian Mew (IPEC) regarding report comments, dated 11/23/2009.

CSI Doc. No. 0700.104.C.019

Ian, This email captures our discussion today concerning your comments on the Unit 2 SSE & SNM. I understand that these two items are the extent of your comments. We will give you a call to go over these and inform you how we have incorporated them prior to sending the final version of the SSE & SNM on or before Dec 4.
1) Ian sent new data to CSIs Ryan Doremus on historical inspections and replacements that he would like incorporated. This may impact plant experience for SNM lines and susceptibility if the entire line has been replaced with FAC resistant material. CSI will assess this data, make the appropriate changes, and provide Ian with a list of impacted lines.
2) Ian requested that CSI provide comments on why SNM lines were evaluated for high consequence of failure. A reason code is given, such as plant shutdown (FT) or unable to isolate (FI), but Ian would like further comments/discussion of this reason. For example, Ian would like to know why a line would cause the plant to shutdown if it fails. For large bore SNM lines, CSI will add the note This large bore line is important to plant operation and/or may be a personnel safety issue upon failure.

CSI will apply comment 2, above to applicable lines in the Unit 3 SNM.

Thanks,



  



Report No. 0700.104-02, Attachment B, Revision 2 Page Attach B-7 of 7