{{#Wiki_filter:*e FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE. RULES 1. Owner: Public Service Electric & Gas Co .. 80 Park Plaza, Newark N.J. 07101 2. *Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. NJ. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (if required) NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Inteival from 06110192 to 10113101 10. Applicable Edition of ASME Section XI 1986 MANUFACTURER STATION OR COMPONENTS OR MANUFACTURER OR INST ALLER PROVINCE NATIONAL APPURTENANCE OR INSTALLER SER NO. NUMBER BOARD NO. #2Reactor Vessel #21 Steam Generator
- #22 Steam Generator
- 23 Steam Generator
- 24 Steam Generator Pressurizer
- Combustion Engineering Westinghouse Tampa Div. P.O. Box 19218 Tampa, FL 33616 II II II II II II Delta Southern -
9so5ii--1 PDR ADOCK 05000311
- Q PDR 67201 Head 67101 Vessel 1201 1202 1004 1204 1211 NIA NIA NIA NIA NIA NIA 20765 68-43 68-44 68-11 68-52 68-48
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark. N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (ifrequired)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NI A. 7. Components inspected: (see pages 1-3) 8. Examination Dates 01103193 to 2116195 9. Inspection Interval from 06110192 to 10113101 10. Applicable Edition of ASME Section XI 1986 MANUFACTURER STATION OR COMPONENTS OR MANUFACTURER OR INSTALLER PROVINCE NATIONAL APPURTENANCE OR INSTALLER SER NO. NUMBER BOARD NO. Chemical United Engineers Volume& & Constructors Control (UE&C) 30 South NIA NIA NIA Piping 17th St., Phila. System PA 19101 .ontainment UE&C NIA NIA NIA pray Piping System Mainsteam UE&C NIA NIA NIA Piping Sys. Pressurizer UE&C NIA NIA NIA Relief Piping Sys. Pressurizer UE&C NIA NIA NIA Spray System Reactor Coolant UE&C NIA NIA NIA Piping Sys. Residual Heat UE&C NIA NIA NIA Removal Piping Sys .
- Page 2
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark. N.J. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Interval from 06/10192 to 10113101 10. Applicable Edition of ASME Section XI 1986 MANUFACTURER STATION OR COMPONENTS OR MANUFACTURER OR INSTALLER PROVINCE NATIONAL APPURTENANCE OR INSTALLER SER. NO. NUMBER BOARD NO. Stearn Gen. Feed Piping System Safety *njection iping Sys .
- UE&C UE&C NIA NIA NIA NIA NIA NIA Page 3
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co .. 80 Park Plaza. Newark. N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge, N.J. 08038 3. Plant Unit z. 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10/13/81.
- 6. National Board Number for Unit NI A 7. Components inspected: (see pages 1-3) 8. Examination Dates 07/03/93 to 2/16/95
- 9. Inspection Inteival from 06/10/92 to 10/13/01 10. Applicable Edition of ASME Section XI 1986 11. Abstracts ofExaminations:
- An inservice examination (ISI) of selected Class 1, 2 and 3 components of Public Service Electric and Gas Company's (PSE&G) Salem Generating Station, Unit 2 (Salem 2), was performed by PSE&G, MQS, Southwest Research Institute (SwRI) and Westinghouse personnel during the October -February 1995 eighth refueling outage. These examinations constituted the Second ISI performed at Salem 2 during the Second 10-y ear Inteival of operation as identified in Attachment # 1 ("Outage ISI Examination Results" For the Second Interval First Period Second Outage (RF94). The completion of this ISI Outage, ended the First Period of the Second Ten Year Inspection Interval.
Exams were performed in accordance with the 1986 edition of ASME Section XI . The ISI was performed utilizing visual (VT), magnetic particle (MT), liquid penetrant (PT), and manual ultrasonic (UT) nondestructive examination techniques. This report also contains augmented examinations required by the Salem Technical Specification, Regulatory Guides, Circulars, and Bulletins issued by the United States Nuclear Regulatory Commission . Page4
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE CODE RULES 1. Owner: Public Service Electric & Gas Co .. 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NI A. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Interval from 06/10192 to 10113101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts of Examinations:
- 11.1 ISI Examination 11.1.1 Southwest Research Institute (SwRI) under the direction of the Salem ISI Group, conducted forty nine (49) manual ultrasonic, eighty seven (87) liquid penetrant, four (4) magnetic particle examinations and one (1) Visual Examination.
Examinations were conducted on the following systems: Class 1 Vessels Piping Pumps Pressurizer Reactor Pressure Vessel Steam Generator CL. Jal and Volume Control Pressurizer Relief System Pressurizer Spray System Reactor Coolant System Residual Heat Removal System Safety Injection System Reactor Coolant Pump Flywheels Page 5
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (ifrequired)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Interval from 06110192 to 10113101 10. Applicable Edition of ASJ.\IB Section XI 1986 11. Abstracts ofExaminations:
- Class 2 Vessels Piping Residual Heat Removal Heat Exchanger Steam Generator Chemical Volume Control System Containment Spray System Main Steam System Residual Heat Removal System Safety Injection Steam Generator Feed System Integrally Welded Attachments Main Steam System Residual Heat Removal System Steam Generator Feed System The following was identified during the course of the examinations:
- 1. A PT examination of weld l.5-SJ-1212-34 (Summary No. 208250), revealed 1 linear recordable indication.
During the relevancy determination process, the surface conditioning proceeded a re-exam with no linear indications identified.
- 2. A PT examination of weld l .5-SJ-1242-7 (Summary No. 200350), revealed 4 linear recordable indications.
During the relevancy determination process, the surface conditioning proceeded a re-exam with no linear indications identified . Page 6
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co .. 80 Park Plaza. Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. N.J. 08038 3. Plant Unit 2. 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Inteival from 06110192 to 10113101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts of Examinations:
- 3. During the UT exam of the RPV Head weld 2-RPVCH-1446C (Summary No. 002200), several areas of corrosion in the vicinity of the weld was found. These corrosion areas were previously evaluated (use as is) on 9187, due to the Canopy Seal leak. 4. A PT examination of weld 2-CV-2214-13 (Summary No. 709750), revealed 2 linear recordable indications.
During the relevancy determination process, the surface conditioning proceeded a re-exam with no linear indications identified . 5. During the VT-I examination ofRPV Closure Head Nuts (2-RPVCH-NUTS 1-54, Summary No. 004900), several discrepancies were found (toolmarks, gouges and ground areas) were found. A re-examination with MT revealed no recordable indications identified in all of these cases. 6. A PT examination of weld 3-PR-1207-1 (Summary No. 054700), revealed 1 linear recordable indication. During the relevancy determination process, the* surface conditioning proceeded a re-exam with no linear indications identified.
- 7. A PT examination of weld 4-PR-1200-3 (Summary No. 054000), revealed 2 linear recordable indications.
During the relevancy determination process, the surface conditioning proceeded a re-exam with no linear indications identified. There were no other unacceptable indications identified . Page7
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P. 0. Box E, Hancock's Bridge, N.J. 0803 8 3. Plant Unit i 4. Owners Certificate of Authorization (ifrequired)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NI A 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Interval from 06110192 to 10113101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts ofExaminations:
11.2. Visual Examinations on Valves and Bolting 11.2.1 The Salem ISI Group conducted eighty four (84) Class 1 bolting VT-2 exams (100%), in conjunction with Relief Request RR-B7 and zero (0) Class 1 valve internal exams. NOTE: Relief Request RR-B7, allowed a visual inspection of all Class 1 bolted connections during refueling outages for evidence of boric acid residue with the insulation removed, In lieu of a VT-2 during plant heat up, per ASME section XI, 1986 edition IW A-5242( a) . There were several Class 1 Bolting exam anomalies noted, including; rust, boric acid accumulation, galling, tool marks, nuts seized on the stud or bolt ect.. Work Orders and/or deficiency reports were generated to document and correct all anoinalies. Examinations were conducted on the following systems. Valves Pressurizer Relief System Safety Injection System Residual Heat Removal System Reactor Coolant System Chemical Volume and Control System Pressurizer Spray System There were no other unacceptable indications identified. 11.3. Visual Examinations of Supports No visual examinations were scheduled I performed this outage .
- Page 8
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CO_DE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10/13181.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Intexval from 06/10192 to 10113101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts ofExaminations:
- 11.4 Presexvice Examinations of Class 1 Bolting Materials The following is a listing of those Class 1 bolting materials that had a Presexvice visual inspection perrormed.
Sum# ID DCP# CJP# W.0.# 004800 2-RPVCH-STUDS NIA S-94-221 941122021 (1-54) REMOVED 022900 23-STG-OMB NIA S-94-194 941024023 023100 21-STG-OMB NIA S-94-192 941024024 023400 22-STG-IMB NIA S-94-193 941024025 051100 6-PR-1205 NIA S-94-227 941120015 -lOFB 052300 6-PR-1204 NIA S-94-226 941119007 -lOFB S-94-007 950102117 053700 6-PR-1203 NIA S-94-225 941120016 -lOFB S-95-006 950102113 255850 2PS3 BOLTING 2EC-3220 PS-94-010 940224127 255975 2PS1 BOLTING 2EC-3220 PS-94-009 940224123 257950 2RH26 BOLTING NIA S-94-190 940926176 Page 9
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES I. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit i 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NI A 7. Components inspected: (see pages 1-3) 8. Examination Dates 01103193 to 2/16195 9. Inspection Interval from 06110192 to 10113101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts of Examinations:
11.5. System Pressure Tests A Class 1 system leakage test was performed in accordance with Section XI, with the Reactor Coolant System in mode 3 (normal operating temperature and pressure) with the insulation installed. No pressure boundary leakage was detected. Minor mechanical leakage was identified and work requests were initiated for repairs. NOTE: Relief request RR-B7 was applied during this refueling outage . Fifty six (56) System Pressure Tests (SPT's) were completed during a Sys.tern Functional or lnseivice Test on Nuclear Class 1, 2 and 3, in accordance with ASME Section XI. Work requests were initiated to correct minor mechanical leakage that was identified. A through wall leak in the accumulator sample line was identified under Work Order# 941028071 (Ref DR# 941108174) All other similar locations were satisfactorily inspected. Twenty seven (27) System Leakage Tests were completed as per NUREG 0578 "TivII Lessons Learned".
- System Pressure Tests were completed on the following systems: Auxiliary Feed Water Chemical and Volume Control Chilled Water Component Cooling Containment Spray Containment Ventilation Control Air Generator Blowdown Main Steam Safety Injection Reactor Coolant Residual Heat Removal Safety Injection There were no other unacceptable indications identified . Sampling Service Water Steam Generator Feed Waste Gas Waste Liquid Waste Recovery
- Page 10
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark. N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. NJ. 08038 3. Plant Unit 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10/13/81.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07/03/93 to 2/16/95 9. Inspection Interval from 06/10/92 to 10/13/01 10. Applicable Edition of ASME Section XI 1986 11. Abstracts ofExaminations:
11.6 Technical Specification 4.7.9(c) "Functional Testing of Selected Hydraulic and Mechanical Snubbers" Hydraulic snubbers were tested using the 10% sample plan of the total number of installed hydraulic snubbers. Initial testing was performed on three (3) hydrauiic snubbers by Siemens Power Corporation, using the AP.I. In-Place Test Machine broken down as follows: 1. One (1) MSIV, 200 Kip, Paul Munroe Snubber. 2. Two (2) Steam Generator (SIG), 1000 Kip Rexnord Snubber. A seal anomaly was found on one (1) SIG snubber and was evaluated as accept as-is . Mechanical small (PSA-1/4 and 1/2) and medium (PSA-1, 3 and 10) type snubbers were tested using Technical Specification (T.S.) 4.7.9(e) 10% sample plan. Initial testing was performed on thirty two (32) mechanical snubbers using the Wyle Laboratories Model 150 snubber testing machine, broken down as follows: 1. Nine (9) medium mechanical snubbers (T.S. sample) 2. Two (2) small mechanical snubbers (T.S. sample). 3. Two (2) small mechanical snubbers (previous refueling outage failure/degrades).
- 4. Eighteen (18) PSA-l/4's, were tested in accordance with PSE&G's augmented examination program. 5. One (1) small Lisega hydraulic snubber. Visual examination of 100% of all plant installed snubbers in the hydraulic and mechanical population was satisfactorily performed.
There were no unacceptable indications/conditions identified during the implementation of the program .
- Page 11
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit i 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Interval from 06/10192 to 10113101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts ofExaminations:
- 11. 7 RCP Flywheel Examination per USNRC Regulatory Guide 1.14 Southwest Research Institute (SwRI) under the direction of the ISI Group performed an in-place UT examination on the Reactor Coolant Pump Flywheel #24 (SIN 1S-75P790).
The Flywheels are tracked by the RCP Motor serial number and original pump location. There were no unacceptable indications identified. 11.8. NRC Bulletin 82-02 "Degradation of Threaded Fasteners in the Reactor Coolant Pressure Boundary of Power Plants" A visual (VT) and Magnetic Particle (MT) exam was performed on the #21 through #24 Steam Generator (hot & cold) Primary Manway Bolts. In addition, an in-place VT exam was performed on the four ( 4) Reactor Coolant Pumps main flange bolting. There were several SIG (hot & cold) Primary Manway bolts replaced, due to thread damage (nicks and dings) found by the visual inspection. These bolts were replaced in kind. There were. no other unacceptable indications identified. 11.9 NRC Bulletin 88-08 "Thermal Stresses in Piping Connected to the Reactor Coolant System" Southwest Research Institute (SwRI) under the direction of the Salem ISI Group, performed augmented ultrasonic and dye penetrant examinations on a total of twenty three (23) components, broken down as follows: Sixteen ( 16) Two (2) Five (5) 1.5 inch Safety Injection welds 2 inch Chemical Volume Control welds 3 inch Chemical Volume CoQtrol Welds There were no unacceptable indications identified. Page 12
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Interval from 06/10192 to 10113101 10. Applicable Edition of AS.ME Section XI 1986 11. Abstracts ofExaminations:
- 11.10 NRC Bulletin 8 8-11 "Pressurizer Surge Line Thermal Stratification" The Salem ISI Group performed visual examinations on all existing surge line pipe supports I HEBA restraints and their associated insulation covering.
A total of nine (9) supports were examined. There were no unacceptable indications identified. 11.11. Erosion I Corrosion UT Thickness Program In response to NRC Bulletin 87-01 and Engineering Directive MEC-94-1071, one hundred and eighty eight (188) components were scheduled for UT thickness examinations. Four (4) of the components were in the plant Heating Steam System. The temperatures were too high to perform UT examinations during this refueling outage. These components were postponed until the summer of 1995, when a system outage is scheduled. Results continued on page 14 and page 15 . Page 13
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co .. 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. N.J. 08038 3. Plant Unit i 4. Owner's Certificate of Authorization (ifrequired)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NI A. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Interval from 06110192 to 10/13101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts of Examinations:
- The following Components were replaced, due to the results of the Erosion/Corrosion UT examinations performed.
SYSTEM COMPONENT ID COMPONENT DESCRIPTION Htr. Drains 2S-HD-426-Ll 10"Xl2" elbow and downstream pipe Htr. Drains 2S-HD-437A-L1 10"Xl2" elbow and downstream pipe Htr. Drains 2S-HD-434A-Ll 10"Xl2" elbow and downstream pipe Htr. Drains 2S-HD-43 l-T2 18" pipe and downstream of tee branch Htr. Vents 2S-HV-4431-Nl 1 11 nozzle Htr. Vents 2S-HV-305-Tl 3" header pipe Htr. Vents 2S-HV-306-T2 4" header pipe Htr. Vents 2S-HV-306-T5 4" header pipe Condensate 2S-C-521-0l 20" flow nozzle Condensate 2S-C-513-0l 20" flow nozzle Page 14
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. N.J. 08038 3. Plant Unit i 4. Owner's Certificate of Authorization (ifrequired)
NIA. 5. Commercial ServiceDate 10/13/81.
- 6. NationalBoardNumberforUnitN/A.
- 7. Components inspected: (see pages 1-3) 8. Examination Dates 07/03/93 to 2/16/95 9. Inspection Interval from 06/10/92 to 10/13/01 10. Applicable Edition of AS:ME Section XI 1986 11. Abstracts of Examinations:
- The following component was repaired via an external weld build-up:
SYSTEM COMPONENT ID COMPONENT DESCRIPTION Htr. Drains 2S-HD-43 l-Ll 18" elbow As a result of these repairs/replacements, an inspection expansion of forty seven ( 4 7) components was performed. This increased the total number of inspections to two hundred and thirty five (23 5) a. b. c. Ten (10) components were replaced. One (1) component required a weld build-up. Two hundred and twenty five (225) were acceptable for continued service, based on minimum wall design requirements. Note: This number also includes the one (1) weld build-up. There were no other unacceptable indications identified . Page 15
- *
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit i 4. Owner's Certificate of Authorization (ifrequired)
NIA. 5. Commercial Service Date 10/13/81.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07/03/93 to 2/16/95 9. Inspection Interval from 06/10/92 to 10/13/01 10. Applicable Edition of ASME Section XI 1986 11. Abstracts ofExaminations:
11.12 Preservice Examination of the Containment Spray and Residual Heat Removal System due to an Engineering Re-analysis (DCP # 2EC-3275-l) The following is a listing of those modified hangers/supports:
- Sum# ID CJP# W.0.# 350054 2P-CSG-309 PS-94-039 940824090 350125 2P-CSH-310 PS-94-039 940824090 576115 2A-RHRS-252 PS-94-037 940805168 577166 2A-RHRG-246 PS-94-037 940805168 700640 2P-CSG-311 PS-94-039 940824090 700645 2P-CSH-303 PS-94-039 940824090 Page 16
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE .INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark. N.J. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (if required)
NI A 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NI A 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195 9. Inspection Interval from 06110192 to 10113101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts of Examinations:
11.13. Preservice Examination of the Service Water System Hangers/Supports, after removal and reinstallation to support other field work The following is a listing of those Hangers/Supports: Sum# ID DCP# CJP# W.0.# 723240 2P-SWR-44 NIA S-94-102 950114003
- 723680 2P-SWR-49 NIA S-94-102 950114003 723690 2P-SWR-50 NIA S-94-102 950114003 723940 2P-21SWS-4 NIA S-94-079 941113013 724260 2P-SWR-42 NIA S-94-102 950114003 725160 2P-SWR-47 NIA S-94-102 950114003 725190 2P-SWR-48 NIA S-94-102 950114003 2EC-3310 S-94-151 941014120 726300 A2-SWR-84 NIA S-94-082 941009005 726400 2A-SWR-85 NIA S-94-079 941113013
- Page 17 I -* FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Setvice Electric & Gas Co .. 80 Park Plaza. Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge. N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Setvice Date 10113181.
- 6. National Board Number for Unit NI A 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 tb 2116195 9. Inspection Interval from 06/10192 to 10113101 10. Applicable Edition of ASME Section XI 1986 11. Abstracts ofExaminations:
11.14. Presetvice Examination of the Auxiliruy F eedWater System Hangers/Supports, due to DCP # 2EC-3l97 I CJP # PS-93-010 I W.O. # 930802086 The following is a listing of those modified Hangers/Supports: Sum# ID 727320 23-AFWA-46
- 733420 22-AFWG-2
- 733780 24-AFWG-3 733790 24-AFWG-2 733870 21-AFWG-47 733920 21-AFWS-50 11.15. Presetvice Examination ofHanger 2C-PRH-205 (Sum# 056150) was performed in accordance with CJP # S-94-230 and W.O. # 941130175.
The Presetvice examination was due to the replacement of a bent or damaged hanger component. Page 18
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, N.J. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit i 4. Owner's Certificate of Authorization (if required)
NIA. 5. Commercial Service Date 10/13/81.
- 6. National Board Number for Unit NI A 7. Components inspected: (see pages 1-3) 8. Examination Dates 07/03/93 to 2/16/95 9. Inspection Interval from 06/10/92 to 10/13/01 10. Applicable Edition of ASME Section XI 1986 11. Abstracts ofExaminations:
11.16. In accordance with an Engineering Request, an augmented examination of several Service Water Hangers/Supports associated with the Containment Fan Coil Units was performed. The following is a listing of those Hangers/Supports: Sum# ID 727760 2C-21SWG-6
- 724350 2C-23SWG-9 724480 2C-23SWA-3007 724580 2C-24SWG-3 724680 2C-24SW A-4007 724880 2C-22SWG-5 724940 2C-21SWA-1007 725000 2C-22SWA-2008 725070 2C-25SWA-5007
- Page 19
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ. 07101 2. Plant: Salem Generating Station P.O. Box E, Hancock's Bridge, N.J. 08038 3. Plant Unit 2 4. Owner's Certificate of Authorization (ifrequired)
NIA. 5. Commercial Service Date 10/13/81.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07/03/93 to 2/16/95 9. Inspection Interval from 06/10/92 to 10/13/01 10. Applicable Edition of ASJ\1E Section XI 1986 11. Abstracts ofExaminations:
- 11.17. Preservice Examination of the Pressurizer Relief System Hanger/Supports. These Hangers/Supports were modified and new ones added, due to the leaking 2PR3, 4 & 5 Relief Valves. The following is a listing of those Hangers/Supports:
Sum# ID DCP# CJP# W.0.# 050950 2C-PRA-150A 2EC-3347 PS-95-002 950112130 052150 2C-PRA-146A 2EC-3347 PS-95-002 950112130 053450 2C-PRA-154A 2EC-3347 PS-95-002 950112130 500412 2-PRG-52 2EC-3348 PS-95-004 950112164 500416 2-PRG-51 2EC-3348 PS-95-004 950112164 500441 2C-PRH-212 2EC-3346 PS-95-003 950112136 2EC-3348 PS-95-004 950112164 500612 2-PRG-40 2EC-3348 PS-95-004 950112164 500633 2-PRG-9 2EC-3348 PS-95-004 950112164 Page 20
- FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE CODE RULES 1. Owner: Public Service Electric & Gas Co .. 80 Park Plaza. Newark. N.J. 07101 2. Plant: Salem Generating Station P.O. Box E. Hancock's Bridge, N.J. 08038 3. Plant Unit 2 4. Owners Certificate of Authorization (ifrequired)
NIA. 5. Commercial Service Date 10113181.
- 6. National Board Number for Unit NIA. 7. Components inspected: (see pages 1-3) 8. Examination Dates 07103193 to 2116195
- 9. Inspection Interval from 06110192 to 10113101 10. Applicable Edition of AS.ME Section XI 1986 11. Abstracts ofExaminations:
Sum# ID DCP# CJP# W.0.# 500635 2C-PRH-211 2EC-3346 PS-95-003 950112136 500640 2C-PRH-211A 2EC-3346 PS-95-003 950112136 500812 2-PRG-26 2EC-3348 PS-95-004 950112164 500816 2-PRG-27 2EC-3348 PS-95-004 950112164 500865 2C-PRH-209 2EC-3346 PS-95-003 950112136 11.18 Preservice Examination of augmented piping welds in the Containment Spray System, due to the addition of new valves 21 & 22CS6 and their associated piping spool pieces. (DCP # 2EC-3173 I CJP # PS-93-092 I WO# 940418179) NOTE: The canst. Jn radiographs and final weld liquid penetrant exam, will satisfy the Preservice examination requirements at this time. The following is a listing of those added piping welds: Sum# ID 350103 8-CS-2225-28 350104 8-CS-2225-29 700930 8-CS-2227-67 700940 8-CS-2227-68
- Page 21
- 11. Abstract ofExamination (see pages 4-21) 12. Abstract of Conditions Noted (see pages 4-21) 13 Abstract of Corrective Measures Recommended and Taken (see pages 4-21) We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code, Section XI. Certificate of Authorization No. (if applicable)
Njtt /0 19 C[S-Signed PSE&G, Owner Expiration Date ;V fH By lt:'Ah-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Insurance Company, Norwood, Massachusetts, have inspected the components described in this Owner's Report during the period 07 /03/93 to 02/16/95, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken .corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. . By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. - ';' Commissions 8 Uc; 5 {, .U/ 1.3 s-i *S ,u.:.T "?. 3 i Inspector's Signature National Board, State,Province and Endorsements Date ____ _____;, 19 *_9_5
- Page 22
., *
- PUBLIC SERVICE ELECTRIC & GAS CO. SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISI EXAMINATION RESULTS (S2RFO#B, REV. 3) CAKPRLE STATUS COMPONENTS SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) April 19, 1995 '"*"'"
Reviewed By: .91.5. Date ____ _ Appcovod 7-Date DATE: 04/19/95
- REVISION:
1 REACTOR PRESSURE VESSEL
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION MERIDIONAL WELDS 002000 2-RPVCH-1446A IN CLOSURE MERIDIONAL WELD AT 300 DEG 002100 2-RPVCH-1446B MERIDIONAL WELD AT 0 DEG. *002200 2-RPVCH-1446C MERIDIONAL WELD AT 60 DEG. 002300 2-RPVCH-14460 MERIDIONAL WELD AT 120 DEG 002400 2-RPVCH-1446E MERIDIONAL WELD AT 180 DEG
- SALEM NUCLEAR POWER STATION UNIT 2 PAGE: OUTAGE ISI EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASHE SEC. XI CATGY EXAM ITEM NO METHOD HEAD CREF. B-A B1.22 B*A B1.22 B-A B1.22 B-A B1.22 B-A B1.22 D\.IG. NO. UTOL UTOIJ UT4S UT4ST UT60 UT60T UTOL UTOW UT4S UT4ST UT60 UT60T UTOL UTOIJ UT4S UT4ST UT60T UT60T UTOL UTOW UT4S UT4ST UT60 UT60T UTOL UTOL UTOW UTOW UT4S/4ST UT4S/4ST UT60/60T UT60/60T PROCEDURE A-3 SH 1) VS2RAISRCE0089Q II II II II II VS2RAISRCE0089Q II II II II II VS2RAISRCE0089Q II II II II II VS2RAISRCE0089Q II II II II II VS2RAISRCE0089Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** x W.0.#941023023 TO PERFORM NOE. x LIMITATION:
EXAMINED CUT) 31% OF THE x --CODE REQUIRED VOLUME, DUE TO THE x FOLLOWING PERMANENT OBSTRUCTIONS: CRD x PENETRATIONS AND SHROUD SUPPORT RING. x **SO-SAM** x W.0.#941023023 TO PERFORM NOE. x --LIMITATION: EXAMINED CUT) 26% OF THE x CODE REQUIRED VOLUME, DUE TO THE x FOLLOWING PERMANENT OBSTRUCTIONS: CRD x PENETRATIONS, SHROUD SUPPORT RING AND x --LIFTING LUG. **SO-SAM** x --W.0.#941023023 CNDE). LIMITATION: x EXAMINED CUT) 3S% OF THE CODE REQUIRED x VOLUME, DUE TO THE CRD PENETRATIONS AND x SHROUD SUPPORT RING OBSTRUCTION. CNF# x 94004 TO DOCUMENT CORROSION AREAS ON x HEAD, PREVIOUSLY EVALUATED ON 9/87 (CANOPY SEAL LEAK) **SO-SAM** x W.0.#941023023 TO PERFORM NOE. x LIMITATION: EXAMINED CUT) 3S% OF THE x CODE REQUIRED VOLUME, DUE TO THE x FOLLOWING PERMANENT OBSTRUCTIONS: CRD x --PENETRATIONS, SHROUD SUPPORT RING AND x LIFTING LUG. **SO-SAM** x W.0.#941023023 TO PERFORM NOE. x --LIMITATION: EXAMINED CUT) 36% OF THE x CODE REQUIRED VOLUME, DUE TO THE x FOLLOWING PERMANENT OBSTRUCTIONS: CRD x PENETRATIONS AND SHROUD SUPPORT RING. x **SO-SAM** x x
- *
- DATE: 04/19/95 REVISION:
1 REACTOR PRESSURE VESSEL
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: MERIDIONAL WELDS IN CLOSURE HEAD CREF. DWG. NO. A-3 SH 1) 002500 2-RPVCH-1446F MERIDIONAL WELD AT 240 DEG B-A B1.22 UTOL UTOW UT45 UT45T UT60 UT60T CIRCUMFERENTIAL WELDS CREF. DWG. NO. A-3 SH 1> 002600 2-RPVCH-6446B DOLLAR PLATE B-A B1 .21 UTOL UTOL UTOW UTOW UT45/45T UT45/45T UT60/60T UT60/60T CIRCUMFERENTIAL WELDS (REF. DWG. NO. A-1 SH. 1) VS2RAISRCE0089Q X II X II X II x II II x x VS2RAISRCE0089Q X x x x x x x x W.0.#941023023 TO PERFORM NOE. LIMITATION: EXAMINED CUT) 54% OF THE CODE REQUIRED VOLUME, DUE TO THE FOLLOWING PERMANENT OBSTRUCTIONS: CRD PENETRATIONS, SHROUD SUPPORT RING AND LIFTING LUG. **50-SAM** W.0.#941023023 TO PERFORM NOE. LIMITATION: EXAMINED CUT) 67°1. OF THE CODE REQUIRED VOLUME, DUE TO THE CRD PENETRATION OBSTRUCTION.
- 50-SAM**
2 002701 2-RPV-7442 VESSEL TO FLANGE B-A B1.30 UT1.5 UT5.7 UT12.5 VS2RAISRCE0103Q X II X W.0.#941023023 TO PERFORM NOE. EXAMINED 100% OF THE WELD. NOZZLE-TO-SAFE END WELDS CREF. DWG. NO. A-2 SH 1) 004601 29-RC-1230-1 NOZZLE TO SAFE-END OUTLET 004621 29-RC-1220-1 NOZZLE TO SAFE-END OUTLET 004651 27.5-RC-1240-5 SAFE-END-TO NOZZLE B-F B5.10 B-F B5.10 B-F B5.10 PT PT PT II x **53-SAM/109-SAM** VS2SSISZZ007SQ X --W.0.#941023023 TO PERFORM NOE. VS2SSISZZ007SQ X --W.0.#941023023 TO PERFORM NOE. VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE.
- DATE: 04/19/95 REVISION:
1 REACTOR PRESSURE VESSEL
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 3 SAFE-END-TO-NOZZLE CREF. DWG. NO. A-2 SH 1) 004671 27.5-RC-1210-5 SAFE-END-TO-NOZZLE WELDS BOLTING (REF. DWG. NO. A-3 004800 2-RPVCH-STUDS 1*54 (REMOVED) CLOSURE STUDS
- 004900 2-RPVCH-NUTS 1-54 CLOSURE NUTS 005000 2-RPV-LIG 1-54 LIGAMENTS 005100 2-RPVCH-WASHERS 1-54 CLOSURE WASHERS
- B-F B5.10 SH 1) B-G-1 B6.30 B-G-1 B6.10 B-G-1 B6.40 B-G-1 B6.50 PT VS2SSISZZ0075Q UT60&88 VS2RAISZZ0100Q UT60&88 II UT60&88 II UT60&88 II UT60&88 II MT VS2SSISZZ0072Q MT II MT II MT II SPARES II VT-1 VS2SSISZZ0073Q VT-1 VT-1 VT-1 VT-1 VT-1 VT-1 VT-1 VT-1 VT-1 UTO VS2RAISZZ0101Q VT-1 VS2SSISZZ0073Q VT-1 II VT-1 II VT-1 'II VT-1 II VT-1 II MT VS2SSISZZ0072Q X --W.0.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. EXA!i x PERFORMED ON 100% OF THE STUDS. x PERFORMED PSI BASELINE ON 2 SPARE STUDS x (#241 & 243), FOR FUTURE USE. REPLACED x STUD #130, PER S-94-221 I 941122021, DUE x TO UNAVAILABILITY OF TRACEABILITY.
- 243 x REPLACED #130 x **60-SAM**
x x x W.0.#941023023 TO PERFORM NOE. EXAM x PERFORMED ON 100% OF THE NUTS. TOOLMARK x INDICATIONS WERE RECORDED, SEE CNF# x 94006 THRU 94010 & SEAT# 94-412. x RE-EXAMINATION WITH MT REVEALED NO --x RECORDABLE INDICATIONS. ACCEPT-AS-IS. --x --x -r.--x --x x --W.0.#941023023 TO PERFORM NDE. EXAM PERFORMED ON 100% OF THE LIGAMENT.
- 60-SAM**
x --W.0.#941023023 TO PERFORM NOE. EXAMINED x 100% OF ALL WASHERS. WASHER #49 HAS AN x AREA OF PITTING ON THE ID SURFACE. SEE x CNF# 94011. AREA IS WITHIN ACCEPTABLE x LIMITS OF THE CODE & MT RE-EXAM REVEALS --x NO RECORDABLE INDICATIONS. ACCEPT AS x IS. I -* *
- DATE: 04/19/95 REVISION:
1 REACTOR PRESSURE VESSEL
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISI EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 4 VESSEL INTERIOR AND CORE SUPPORT STRUCTURES CREF. DWG. NO. A-3 SH 1) 006510 VESSEL INTERIOR B-N-1 VT-3 VSCRAISRCE0102Q X B13.10 CONTROL ROD DRIVE HOUSINGS (REF. DWG. NO. A-4 SH 1) 006900 2-CRDH-38 THRU 78 CRD HOUSINGS B-0 PT (#48) VS2SSISZZ0075Q B14.10 PT (#70) II PT (#72) II x x x W.0.#941023023 TO PERFORM NOE. WESTINGHOUSE PERFORMED THE VESSEL INTERIOR EXAM. W.0.#941023023 TO PERFORM NOE. EXAM PERFORMED ON THREE WELDS CCRDH# 48, 70 & 72).
- *
- DATE: 04/19/95 REVISION:
1 PRESSURIZER
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISI EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 5 NOZZLE*TO-SAFE END WELDS CREF. DWG. NO. A-5 SH 1) 011800 6-PR-1205-1 NOZZLE TO SAFE-END B-F B5.40 BOLTING CREF. DWG. NO. A-5 SH 1) 012500 2-PZR-MB 1-16 MANWAY BOLTS B-G-2 B7.20 ANGLE CONF VS2RAISZZ0082Q VT-2 SCSSISZZ0006Q W.0.#941023023 TO PERFORM NOE. UT ANGLE CONFIRMATION WAS ATTEMPTED, BUT DUE TO THE SAFE-END CONFIGURATION THE INFORMATION COULD NOT BE OBTAINED.
- 64-SAM** X --W.0.#941023023 TO PERFORM NOE.
DATE: 04/19/95 REVISION: 1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 6
- STEAM GENERATORS OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, .REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS
- *
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASME SEC. XI CATGY EXAM ITEM NO METHOD CIRCUMFERENTIAL WELDS (REF. DWG. NO. A*8 SH 1) 020300 22-STG-LHTS B-B UTOL LOWER HEAD TO TUBE SHEET B2.40 UTOW UTOW UT45 UT45T UT60 UT60T PROCEDURE VS2RAISZZ0088Q II II VS2RAISRCE0084Q II II II N 0 0 G. T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** x --W.0.#941023023 TO PERFORM NOE. x 100% OF THE WELD. UT45 FOUND A EXAMINED x GEOMETRIC REFLECTOR FROM THE TUBE SHEET -x -RADIUS. x **42-SAM & 118-SAM** x x --NOZZLE INSIDE RADIUS SECTION (REF. DWG. NO. A-8 SH 1) 020800 31-STG-1220-IRS OUTLET NOZZLE IRS 021200 29-STG-1220-IRS INLET NOZZLE IRS BOLTING CREF. DWG. 022800 24-STG-OMB NO. A-6 OUTLET MANWAY BOLTING BOLTING CREF. DWG. NO. A-7 022900 23-STG-OMB OUTLET HANWAY BOLTING B-D UT28RL B3.140 UT38RL B-D UT28RL B3.140 UT38RL SH 1) B-G-2 VT-2 B7.30 MT VT-1 SH 1) B-G-2 VT-2 B7.30 MT VT-1(0LD) VT-1(NEW) VS2RAISRCE0083Q X II x VS2RAISRCE0083Q X II X SCSSISZZ0006Q x SHRAISZZ0201Q x SCSSISZZ0010Q x SCSSISZZ0006Q x SHRAISZZ0201Q x SCSSISZZ0010Q x II x --W.0.#941023023 TO PERFORM NOE. LIMITATION: EXAM LIMITED TO APPROXIMATELY 80% CODE COVERAGE, DUE TO A PERMANENT INSULATION SUPPORT RING. CALCULATED LENGTH OF EXAM SURFACE = 153.93 11 , LENGTH OF LIMITATION = 30 11* **117-SAM** W.0.#941023023 TO PERFORM NOE. LIMITATION: EXAM LIMITED TO APPROXIMATELY 73% CODE COVERAGE, DUE TO A PERMANENT INSULATION SUPPORT RING. CALCULATION LENGTH OF EXAM SURFACE = 154 11 , LENGTH OF LIMITATION = 73 11* **117-SAM** W.0.#941023023 TO PERFORM NOE. MQS PERFORMED FLORESCENT MT. W.0.#941023023 TO PERFORM NOE. A-E I NB88-02 -VT-1 (PSE&G) & FLORESCENT MT (MQS). PSI BASELINE PERFORMED ON REPLACED BOLT #23C1 PER PR# 941109197 & S-94-194 & W.0.# 941024023
- l I DATE: 04/19/95 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 7 REVISION:
1 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3)
- SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 1 CAKPRLE STATUS COMPONENTS STEAM GENERATORS N 0 ASME 0 G T SEC. XI R E H
SUMMARY
EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER !DENT! Fl CATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** -------------------------------------
BOLTING DWG. NO. A-8 SH 12 023000 22-STG-OMB B-G-2 VT-2 SCSSISZZ0006Q x --W.0.#941023023 TO PERFORM NOE. MQS OUTLET HANWAY BOLTING B7.30 MT SHRAISZZ0201Q x PERFORMED FLORESCENT MT. VT-1 SCSSISZZ0010Q x BOLTING DWG. NO. A-9 SH 12 023100 21-STG-OMB B-G-2 VT-2 SCSSISZZ0006Q x W.0.#941023023 TO PERFORM NOE. A-E I OUTLET MANWAY BOLTING B7.30 MT SHRAISZZ0201Q x NB88-02 -VT-1 CPSE&G) & FLORESCENT MT VT-1COLD) SCSSISZZ0010Q --x (MQS). PSI BASELINE PERFORMED ON VT-1CNEW) SCSSISZZ0010Q x REPLACED BOLTS #21C5 & #21C8 PER PR# 941109193 & S-94-192 & W.0.# 941024024. BOLTING CREF. DWG. NO. A-6 SH 1> 023200 24-STG-IMB B-G-2 VT-2 SCSSISZZ0006Q x --W.0.#941023023 TO PERFORM NOE. MQS
- INLET MANWAY BOLTING B7.30 MT SHRAISZZ0201Q x PERFORMED FLORESCENT MT. VT-1 SCSSISZZ0010Q x BOLTING CREF. DWG. NO. A-7 SH 1> 023300 23-STG-IMB B-G-2 VT*2 SCSSISZZ0006Q x W.0.#941023023 TO PERFORM NOE. MQS INLET MANWAY BOLTING B7.30 MT SHRAISZZ0201Q x PERFORMED FLORESCENT MT. VT-1 SCSSISZZ0010Q x BOLTING (REF. DWG. NO. A-8 SH 1> 023400 22-STG-IMB B-G-2 VT-2 SCSSISZZ0006Q x W.0.#941023023 TO PERFORM NOE. A-E I INLET MANWAY BOLTING B7.30 MT SHRAISZZ0201Q x NB88-02 -VT-1 (PSE&G) & FLORESCENT MT VT-1(0LD)
SCSSISZZ0010Q --x (MQS). PSI BASELINE PERFORMED ON VT-1CNEW) II x REPLACED BOLT #22-H4 PR# 941109195 & S-94-193 & W.0.# 941024025. BOLTING DWG. NO. A-9 SH 12 023500 21-STG-IMB B-G-2 VT-2 SCSSISZZ0006Q x W.0.#941023023 TO PERFORM NOE. MQS INLET MANWAY BOLTING B7.30 MT SHRAISZZ0201Q x --PERFORMED FLORESCENT MT. VT-1 SCSSISZZ0010Q x *
- *
- DATE: 04/19/95 REVISION:
1 CHEMICAL AND VOLUME CONTROL SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 8 12-CV-1243 CREF. DWG. NO. A-10 SH 1) 030000 12-CV-1243-1 CAP TO PIPE B-J B9.11 3-CV-1241 CREF. DWG. NO. A-12 SH 1> 034500 3-CV-1241-13 VALVE 2CV80 TO ELBOW 034600 3-CV-1241-14 ELBOW TO BRANCH CONNECTION B-J B9.21 B-J B9.21 3-CV-1231 CREF. DWG. NO. A-13 SH 1) 035300 3-CV-1231-7 PIPE TO ELBOW 035400 3-CV-1231-8 ELBOW TO PIPE B-J B9.21 B-J B9.21 PT UT45 UT45T UT45TAN PROFILE UTOL VS2SSISZZ0075Q VS2RAISZZ0082Q II II VS2RAISZZ0088Q II X W.0.#941023023 TO PERFORM NOE. PERFORM -X -UT ANGLE CONFIRMATION, TO SATISFY X S2RF0#7'S EXAMS. UT45 GEOMETRIC x x REFLECTOR IS FROM THE WELD ROOT, SEEN INTERMITTENTLY 360 DEGREES. **21-SAM** ANGLE CONF VS2RAISZZ0082Q X PT UT45 UT45T UT45TAN PROFILE PT UT45 UT45T UT60 UT45TAN PROFILE PT UT45 UT45T PT UT45 UT45T VS2SSISZZ0075Q VS2RAISZZ0082Q II II II VS2SSISZZ007SQ VS2RAISZZ0082Q II II II II VS2SSISZZ0075Q VS2RAISZZ0082Q II VS2SSISZZ007SQ VS2RAISZZ0082Q II X W.0.#941023023 TO PERFORM NOE. A-E, PT -X -& UT PER NRC BULLETIN 88-08. UT45 x x x x x x x GEOMETRIC REFLECTOR IS FROM THE ROOT, SEEN 360 DEGEES INTERMITTENTLY. LIMITATION: UT EXAM LIMITED TO 83%, DUE TO CONFIGURATION OF VALVE * **30-SAM** W.0.#941023023 TO PERFORM NOE. A-E, PT & UT PER NRC BULLETIN 88-08. LIMITATION: UT EXAM LIMITED TO 81%, DUE TO BRANCH CONNECTION CONFIGURATION.
- 30-SAM**
X W.0.#941023023 TO PERFORM NOE. -X -LIMITATION: PT EXAM LIMITED TO 62% CODE X COVERAGE, DUE TO PROXIMITY OF A PERMANENT SUPPORT. THE UT EXAM WAS NOT AFFECTED. A-E, PT & UT PER NRC BULLETIN 88-08. UT45 GEOMETRIC REFLECTOR FROM THE WELD ROOT. **30-SAM** X W.0.#941023023 TO PERFORM NOE. X LIMITATION: PT EXAM LIMITED TO 62% CODE X --COVERAGE, DUE TO PROXIMITY OF A PERMANENT SUPPORT. THE UT EXAM WAS NOT AFFECTED. A*E, PT & UT PER NRC BULLETIN 88-08 * **30-SAM**
- DATE: 04/19/95 REVISION:
1 CHEMICAL AND VOLUME CONTROL SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS C:JMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 9 3-CV-1231 CREF. DWG. NO. A-13 SH 1) 036000 3-CV-1231-14 B-J PT VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE. A-E, PT PIPE TO VALVE 2CV274 B9.21 UT45 VS2RAISZZ0082Q -x -& UT PER NRC BULLETIN 88-08. UT45 UT45T II x GEOMETRIC REFLECTOR IS FROM THE WELD UT45TAN II x ROOT AND CAN BE SEEN INTERMITTENTLY 360 PROFILE II DEGREES. LIMITATION: UT EXAM LIMITED TO 82%, DUE TO VALVE CONFIGURATION.
- 30-SAM**
2-CV-1275 (REF. DWG. NO. A-15 SHT 2) 040900 2-CV-1275-43 B-J PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. UNABLE VALVE 2CV76 TO PIPE B9.40 UT45 VS2RAISZZ0087Q x TO SUCCESSFULLY PERFORM A BEAM ANGLE UT45T II x -CONFIRMATION, DUE TO PIPE CONFIGURATION. UT70 II x -A-E, PT & UT PER NRC BULLETIN 88-08. ANGLE CONF VS2RAISZZ0082Q
- 111-SAM**
- 041000 2-CV-1275-44 PIPE TO BRANCH CONNECTION B-J PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. A-E, PT B9.40 UT45 VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. UT45T II x UT70 II x **111-SAM**
- DATE: 04/19/95 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 10 REVISION:
1 OUTAGE ISI EXAMINATION RESULTS (S2RF0#8, REV. 3)
- SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS PRESSURE RELIEF SYSTEM N 0 ASME 0 G T SEC. XI R E H
SUMMARY
EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** -------------------------------------
6-PR-1205 (REF. DWG. NO. A-17> 050950 2C-PRA-150A F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER 2EC*3347-1 I ANCHOR F1.10 PS-95-002 I 950112130 (MOO., DUE TO 2PR3,4&5 VLV LKG). 051100 6-PR-1205-10FB B-G-2 VT-2 SCSSISZZ0006Q x W.0.#941023023 TO PERFORM NOE. VT-1 FLANGE BOLTING C2PR5) B7.50 VT-1(0LD) SCSSISZZ0010Q --x 10'0 SEVERAL BOLTING DISCREPANCIES VT-1(NEW) SCSSISZZ0010Q x CPR#941207123). PSI BASELINE PER MT SHRAISZZ0201Q x S-94-227 I 941120015 (REPLACED ALL VT* 1(NEW) SCSSISZZ0010Q x NUTS). PSI BASELINE PER S-94-240 I VT* 1(NEW) SCSSISZZ0010Q x 941230091 CALL BOLTING MATERIALS REPLACED W/NEW 2PR5, DUE TO VLV LKG 6-PR-1204 (REF. DWG. NO. A-18 SH 1) 051300 6-PR-1204-2 B-J PT VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE.
- SAFE-END TO ELBOW B9.11 UT45 VS2RAISZZ0082Q x --UT45T II x UT45TAN II x PROFILE VS2RAISZZ0088Q
- 25-SAM**
051500 6-PR-1204-4 B-J ANGLE CONF VS2RAISZZ0082Q x --W.0.#941023023 TO PERFORM NOE. PERFORM ELBOW TO PIPE B9.11 PT UT ANGLE CONFIRMATION, TO SATISFY S2RF0#7 EXAMS. **25-SAM** 6-PR-1204 (REF. DWG. NO. A-18) 052150 2C-PRA-146A F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER 2EC-3347-1 I ANCHOR F1.10 PS-95-002 I 950112130 (MOO. I DUE TO 2PR3,4&5 VLV LKG). 052300 6-PR-1204*10FB B*G-2 VT-2 SCSSISZZ0006Q x W.0.#941023023 TO PERFORM NOE. FLANGE BOLTING (2PR4) B7.50 VT-1(0LD) SCSSISZZ0010Q x VT-1COLD) 10'0 SEVERAL BOLTING VT-1(NEW) SCSSISZZ0010Q x --DESCREPANCIES (PR#941207123). PSI MT SHRAISZZ0201Q x --BASELINE PER S-94-226 I 941119007 VT-1(NEW) SCSSISZZ0010Q x --(REPLACED ALL NUTS & 2 STUDS). PSI PER S-95-007 I 950102117 (SOME BOLTING MTRLS REPLACED W/NEW 2PR4, DUE TO LKG *
- *
- DATE: 04/19/95 REVISION:
1 PRESSURE RELIEF SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION
6-PR-1203 DWG. NO. A-19 6-PR-1203-3 ELBOW TO ELBOW 6-PR-1203 CREF. DWG. NO. A-19) 053450 2C-PRA-154A ANCHOR 053700 6-PR-1203-10FB FLANGE BOLTING C2PR3) 4-PR-1200 (REF. DWG. NO. A-20 054000 4-PR-1200-3 ELBOW TO PIPE 3-PR-1207 CREF. DWG. NO. A-20 054700 3-PR-1207-1 REDUCER TO PIPE SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 11 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 1 CAKPRLE STATUS COMPONENTS N 0 ASME 0 G T SEC. XI R E H CATGY EXAM E 0 E REMARKS ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** .........................
SH B-J PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NDE. UT45 B9.11 UT45 VS2RAISZZ0082Q -x -GEOMETRIC REFLECTOR IS FROM THE WELD UT45T II x ROOT. UT45TAN II x PROFILE VS2RAISZZ0088Q
- 25-SAM**
F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER 2EC-3347-1 I F1.10 PS-95-002 I 950112130 (MOD. I DUE TO 2PR3,4&5 VLV LKG). B-G-2 VT-2 SCSSISZZ0006Q x --W.0.#941023023 TO PERFORM NOE. VT-1 B7.50 VT-1(0LD) SCSSISZZ0010Q --x ID'D SEVERAL BOLTING DISCREPANCIES VT-1(NEW) SCSSISZZ0010Q x CPR#941207123). PSI BASELINE PER MT SHRAISZZ0201Q x S-94-225 I 941120016 (REPLACED ALL VT-1(NEW) SCSSISZZ0010Q x NUTS) *. PSI BASELINE PER S-95-006 I 950102113 CALL BOLTING MATERIALS REPLACED W/NEU 2PR3, DUE TO VLV LKG SH 1) B-J PT VS2SSISZZ0075Q x W;0.#941023023 TO PERFORM NOE. THE PT B9.11 UT THICK VS2RAISZZ0088Q x --EXAM REVEALED 2 LINEAR RECORDABLE PROFILE VS2RAISZZ0088Q x ' --INDICATIONS. DURING THE RELEVANCY UT45 VS2RAISZZ0082Q x DETERMINATION PROCESS, SURFACE UT45T II x --CONDITIONING PROCEEDED A RE-EXAM WITH NO UT45TAN II x LINEAR INDICATIONS IDENTIFIED (REF. CNF# PT RE-EXAM VS2SSISZZ0075Q x 94013 & PR#941109145).
- 28-SAM-R**
SH 1) B-J PT VS2SSISZZ0075Q --x W.0.#941023023 TO PERFORM NOE. THE PT B9.21 UT THICK VS2RAISZZ0088Q x --EXAM REVEALED 1 LINEAR RECORDABLE PT RE-EXAM VS2SSISZZ0075Q x INDICATION. DURING THE RELEVANCY DETERMINATION PROCESS, SURFACE CONDITIONING PROCEEDED A RE-EXAM WITH NO LINEAR INDICATIONS IDENTIFIED (REF CNF# 94012 & PR#941109145)
- DATE: 04/19/95 REVISION:
1 PRESSURE RELIEF SYSTEM
SUMMARY
EXAMINATION AREA SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM N 0 R E 0 G T E H 0 E REMARKS PAGE: 12 NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** 3-PR-1207 CREF. DWG. NO. A-20 SH 1) 054800 3-PR-1207-2 PIPE TO ELBOW . 055655 3-PR-1207-10C PIPE TO CAP 3-PR-1206 CREF. 055900 3-PR-1206-1 REDUCER TO PIPE
- DWG. NO. A-24 3-PR-1206 (REF. DWG. NO. A-24)
- 056150 2C-PRH-205 VAR.SUPPORT,TYP.C,SZ 5,CL-360,HL-296 056855 3-PR-1206-10C PIPE TO CAP B-J B9.21 B-J B9.21 SH 1) B-J B9.21 F-A F1.10 B-J B9.21 PT VS2SSISZZ0075Q UT THICK VS2RAISZZ0088Q PT RE-EXAM VS2SSISZZ0075Q PT VS2SSISZZ0075Q PT VS2SSISZZ0075Q VT-3 S2SSISZZ0011Q PT VS2SSISZZ0075Q
x W.0.#941023023 TO PERFORM NOE. THE PT x EXAM REVEALED 2 LINEAR INDICATIONS. x --DURING THE RELEVANCY DETERMINATION PROCESS, THE SURFACE CONDITIONING PROCEEDED A RE-EXAM WITH NO LINEAR INDICATIONS IDENTIFIED (REF. CNF#94014). x --W.0.#941023023 TO PERFORM NOE
- x --W.0.#941023023 TO PERFORM NOE. x --PSI BASELINE PERFORMED PER S-94-230 I 941130175 (REPLACEMENT OF BENT OR DAMAGED HANGER COMPONENTS). X --W.0.#941023023 TO PERFORM NOE.
DATE: 04/19/95 REVISION: 1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 13
- OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS
- PRESSURIZING SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE 14-PS-1231 CREF. DWG. NO. A-25 SH 1) 060000 14-PS-1231-1 NOZZLE TO PIPE B-F B5.40 ANGLE CONF VS2RAISZZ0082Q 14-PS-1231 tPSE&G #14"*2PS1016J CREF. DWG. NO. A-25 SH 1> 060100 2C-PSH-1 VAR.SUPPORT,TYP.A SZ13,CL-2904,HL* 3339 14-PS-1231 060110 R-240185-1 SUPPORT 060120 R-240185-2 SUPPORT 060130 R-240185-3 SUPPORT 060140 R-240185-4 SUPPORT 060150 R-240185-5 SUPPORT 060160 R-240185-6 SUPPORT [PSE&G #14 11*2PS1016J F-A VT-3 S2SSISZZ0011Q F1.10 A-E VT-3 S2SSISZZ0011Q NB88-11 A-E VT-3 S2SSISZZ0011Q NB88-11 A-E VT-3 S2SSISZZ0011Q NB88-11 A-E VT-3 S2SSISZZ0011Q NB88-11 A-E VT-3 S2SSISZZ0011Q NB88-11 A-E VT-3 S2SSISZZ0011Q NB88*11
- N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.#941023023 TO PERFORM NOE. PERFORM UT ANGLE CONFIRMATION, TO SATISFY S2RF0#7'S EXAMS. **77-SAM**
X --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88-11. x --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88-11. x --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88-11. X --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88-11. X --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88*11. X --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88-11. X --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88-11.
- DATE: 04/19/95 REVISION:
1 PRESSURIZING SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G-T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 14 14-PS-1231 [PSE&G #14 11-2PS1016J CREF. DWG. NO. A-25 SH 1) 060250 2C-PSH-2 VAR.SUPPORT,TYP.A SZ14,CL-3241,HL-3663 F-A F1 .10 VT-3 S2SSISZZ0011Q 14-PS-1231 tPSE&G #14 11-2PS1016J CREF. DWG. NO. A-25> 060350 2C-PSH-3 VAR.SUPPORT,TYP.A SZ13,CL-2895,HL-3212 F-A F1.10 VT-3 S2SSISZZ0011Q X --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88-11. X --W.0.#941023023 TO PERFORM NOE. A-E ON PZR SURGE LINE PER NRC BULLETIN 88-11.
- DATE: 04/19/95 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 15 REVISION:
1 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3)
- SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS REACTOR COOLANT SYSTEM N 0 ASME 0 G T SEC. XI R E H
SUMMARY
EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** -------------------------------------
31-RC-1240 CREF. D\JG. NO. A-29 SH 1) 070000 31-RC-1240-1 B-F PT VS2SSISZZ0075Q x \J.0.#941023023 TO PERFORM NOE. NOZZLE TO ELBOW B5.130 UT45 VS2RAISZZ0082Q x LIMITATION: NO UT FROM EITHER SIDE, DUE UT45T II x TO ELBOW ACOUSTIC PROPERTIES AND NOZZLE CONFIGURATION.
- 37-SAM CALT#01)**
31-RC-1220 CREF. DWG. NO. A-31 SH 1) 075800 31-RC-1220-4LU-I B-J PT VS2SSISZZ0075Q x --\J.0.#941023023 TO PERFORM NOE. LONGITUDINAL B9.12 LIMITATION: NO UT FROM EITHER SIDE OF THE WELD, DUE TO ACOUSTIC PROPERTIES OF THE CASTING. **37-SAM CALT#01)** 075900 31-RC-1220-4LU-O B-J PT VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE.
- LONGITUDINAL B9.12 LIMITATION:
NO UT FROM EITHER SIDE OF WELD, DUE TO ACOUSTIC PROPERTIES OF THE CASTING. **37-SAM CALT#01)** 076000 31-RC-1220-4 B-J PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. ELBOW TO PIPE B9.11 UT45 VS2RAISZZ0082Q x --PERFORMED UT ANGLE CONFIRMATION. UT45T II x LIMITATION: UT45 EXAM LIMITED TO 84% ANGLE CONF II x CODE COVERAGE, DUE TO ACCOUSTIC PROPERTIES OF THE CASTING & THE BRANCH CONNECT! ON. **37-SAM CALT#01)**
- DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE:
- REACTOR PRESSURE VESSEL OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV.' 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS
- ASHE SEC. XI CATGY EXAM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE 29-RC-1230 CREF. DWG. NO. A-2A SH 1) 079201 29-RC-1230-2 SAFE-END TO PIPE B-J B9.11 29-RC-1220 CREF. DWG. NO. A-2A SH 1) 081401 29-RC-1220-2 SAFE-END TO PIPE B-J B9.11 PT VS2SSISZZ0075Q ANGLE CONF VS2RAISZZ0082Q PT VS2SSISZZ0075Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** x x W.0.#941023023 TO PERFORM NOE. PERFORMED UT ANGLE CONFIRMATION TO SATISFY S2RF0#7 EXAMS. X --W.0.#941023023 TO PERFORM NOE. 16
- *
- DATE: 04/19/95 REVISION:
1 REACTOR COOLANT SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE !SI EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL,- FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 17 27.5-RC-1240 CREF. DWG. NO. A-37 SH 1) 083650 27.5-RC-1240-1A BRANCH CONNECTION TO CAP B-J B9.21 27.5-RC-1230 CREF. DWG. NO. A-38 SH 1) 085000 27.5-RC-1230-1BC-5 B-J 4 IN. BRANCH CONNECTION 89.31 PT PT UT45 UT45TAN UT32T UT32TAN UTOL PROFILE ANGLE CONF VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. VS2RAISZZ0082Q -x -LIMITATION: UT EXAM LIMITED TO 55% CODE II x COVERAGE AND UT ANGLE CONFORMATION NOT II x PERFORMED, DUE TO BRANCH CONNECTION II x CONFIGURATION. UT45 GEOMETRIC REFLECTOR II x IS FROM THE WELD ROOT. VS2RAISZZ0088Q
- 115-SAM**
II
- *
- DATE: 04/19/95 REVISION:
1 REACTOR PRESSURE VESSEL
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOO PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 27.5-RC-1240 (REF. DWG. NO. A-2A SH 1) 085401 27.5-RC-1240-4 ELBOW TO SAFE-END B-J B9.11 PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. 18
- *
- DATE: 04/19/95 REVISION:
1 REACTOR COOLANT SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POYER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 19 27.5-RC-1210 CREF. DYG. NO. A-40 SH 1) 086800 27.5-RC-1210-1BC-3 B-J PT VS2SSISZZ007SQ x Y.0.#941023023 TO PERFORM NOE. 10 IN. BRANCH CONNECTION B9.31 UT45 VS2RAISZZ0082Q -x -LIMITATION: UT EXAM LIMITED TO 55% CODE UT45TAN II x --COVERAGE AND NO BEAM ANGLE CONFIRMATION, UT39T II x DUE TO BRANCH CONNECTION CONFIGURATION. UT39TAN II x UT45 GEOMETRIC REFLECTOR IS FROM THE PROFILE II INSIDE RADIUS. ANGLE CONF II **114-SAM** 086900 27.5-RC-1210-1BC-4 B-J PT VS2SSISZZ0075Q x --Y.0.#941023023 TO PERFORM NOE. 4 IN. BRANCH CONNECTION B9.31 UT45 VS2RAISZZ0082Q -x -LIMITATION: UT EXAM LIMITED TO 52% CODE UT45TAN II x COVERAGE & NO UT ANGLE CONFORMATION, DUE OL II x TO BRANCH CONNECTION CONFIGURATION. UT32T II x UT45 GEOMETRIC REFLECTOR IS FROM THE PROFILE II YELD ROOT. ANGLE CONF II **115-SAM**
- *
- DATE: 04/19/95 REVISION:
1 REACTOR PRESSURE VESSEL
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATlON SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE !SI EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. Xl CATGY EXAM l TEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 27.5-RC-1210 CREF. DWG. NO. A-2A SH 1) 087401 27.5-RC-1210-4 ELBOW TO SAFE-END B-J B9.11 PT VS2SSlSZZ0075Q X --W.0.#941023023 TO PERFORM NOE. 20 DATE: 04/19/95 REVISION: 1
- REACTOR COOLANT SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASHE SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 2-RC-1241 CREF. DWG. NO. A-47 SH 1) 100200 2-RC-1241-3 PIPE TO VALVE 24RC13 *
- B-J B9.40 PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. 21 DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE:
- SAFETY INJECTION SYSTEM OUTAGE ISI EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS
- 2-SJ-1239 CREF. DWG. NO. A-92 SH 1) 188000 2-SJ-1239-2FB B-G-2 FLANGE BOLTING (NEAR, 23SJ143) 87.50 2-SJ-1237 CREF. DWG. NO. A-93 SH 1) 189800 2-SJ-1237-7FB FLANGE BOLTING B-G-2 87.50 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. 22
- DATE: 04/19/95 REVISION:
1 SAFETY INJECTION SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POYER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RFO#B, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 2-SJ-1237 (REF. DWG. NO. A-93 SH 1) 190250 2-SJ-1237-16 PIPE TO ELBO\.I 190300 2-SJ-1237-17 ELBOW TO PIPE B-J B9.40 B-J B9.40 2-SJ-1229 (REF. DWG. NO. A-94 SH 1) 190950 2-SJ-1229-2 PIPE TO FLANGE B-J B9.40 PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE.
- 191000 2-SJ-1229-2FB FLANGE BOLTING B-G-2 B7.50 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE.
- 191050 2-SJ-1229-3 FLANGE TO PIPE 191100 2-SJ-1229-4 PIPE TO VALVE 22SJ143 B-J B9.40 B-J B9.40 2-SJ-1228 (REF. DWG. NO. A-96 SH 1) 193300 2-SJ-1228-2 PIPE TO FLANGE 193350 2-SJ-1228-2FB FLANGE BOLTING 193700 2-SJ-1228-9 TEE TO REDUCER B-J B9.40 B-G-2 B7.50 B-J B9.40 PT VS2SSISZZ0075Q x --w.o.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. 23
- DATE: 04/19/95 REVISION:
1 SAFETY INJECTION SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POYER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 2-SJ-1228 (REF. DYG. NO. A-96 SH 1) 193750 2-SJ-1228-10 TEE TO PIPE B-J B9.40 2-SJ-1228 CREF. DYG. NO. A-96 SH 2) 194550 2-SJ-1228-26 ELBOY TO PIPE 194600 2-SJ-1228-27 PIPE TO ELBOY B-J B9.40 B-J B9.40 PT VS2SSISZZ0075Q X --Y.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --Y.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --Y.0.#941023023 TO PERFORM NOE.
- 2-SJ-1219 CREF. DYG. NO. A-98 SH 1) 196400 2-SJ-1219-1 8-J VS2SSISZZ0075Q X --Y.0.#941023023 TO PERFORM NOE.
- TEE TO PIPE 89.21 196450 2-SJ-1219-2 PIPE TO FLANGE 196500 2-SJ-1219-2F8 FLANGE 80L TING 197600 2-SJ-1219-24 EL80Y TO PIPE B-J 89.40 8-G-2 B7.50 8-J 89.40 2-SJ-1218 CREF. DYG. NO. A-99 SH 1) 198200 2-SJ-1218-3 TEE TO REDUCER 8-J B9.40 PT PT VS2SSISZZ0075Q X --Y.0.#941023023 TO PERFORM NOE. VT-2 SCSSISZZ0006Q X --Y.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --Y.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --Y.0.#941023023 TO PERFORM NOE. 24
- *
- DATE: 04/19/95 REVISION:
1 SAFETY INJECTION SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi-EXAMiNATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS CCMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 25 2*SJ-1218 <REF. DWG. NO. A-99 SH 1) 198350 2-SJ-1218-5FB FLANGE BOL Tl NG 198450 2-SJ-1218-7 PIPE TO VALVE 21SJ138 198500 2-SJ-1218-8 VALVE 21SJ138 TO PIPE 1.5-SJ-1242 CREF. 200200 1.5-SJ-1242-4 PIPE TO ELBOW 200250 1.5-SJ-1242-5 ELBOW TO PIPE 200300 1.5-SJ-1242-6 PIPE TO ELBOW 200350 1.5-SJ-1242-7 ELBOW TO PIPE 200450 1.5-SJ-1242-SFB FLANGE BOL Tl NG DWG. NO. B-G-2 B7.50 B-J B9.40 B-J B9.40 A-101 SH B-J B9.40 B-J B9.40 B-J B9.40 B-J B9.40 B-G-2 B7.50 VT-2 SCSSISZZ0006Q VT-3 S2SSISZZ0009Q PT VS2SSISZZ0075Q PT VS2SSISZZ0075Q
- 1) PT VS2SSISZZ0075Q PT VS2SSISZZ0075Q PT VS2SSISZZ0075Q PT VS2SSISZZ0075Q UT THICK VS2RAISZZ0088Q PT RE-EXAM VS2SSISZZ0075Q VT-2 SCSSISZZ0006Q x W.0.#941023023 TO PERFORM NOE. BORIC x ACID WAS FOUND ON THE BOLTED CONNECTION.
AR#941419231 WAS WRITTEN TO REMOVE AS NECESSARY THE AFFECTED BOLTING. W.0.# 941021153, REMOVED 1 STUD, AND A SATISFACTORY VT-3 WAS PERFORMED. x --W.0.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. --x W.0.#941023023 TO PERFORM NOE. THE PT x EXAM REVEALED 4 LINEAR RECORDABLE x INDICATIONS. DURING THE RELEVANCY DETERMINATION PROCESS, THE SURFACE CONDITIONING PROCEEDED A RE-EXAM WITH NO LINEAR INDICATIONS IDENTIFIED (REF. CNF#94003 & SEAT# 94-411) x --w.o.#941023023 TO PERFORM NOE. I j DATE: 04/19/95 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 26 REVISION: 1 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3)
- SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H
SUMMARY
EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE c M R **CALI BRA Tl ON BLOCK** ------------------------------
*-----
____________ .. __ ---------------------------------------- 1.5-SJ-1242 DWG. NO. 202000 1.5-SJ-1242-39 VALVE 24SJ17 TO PIPE 202050 1.5-SJ-1242-40 PIPE TO ELBOW 202100 1.5-SJ-1242-41 ELBOW TO PIPE
- 202150 1.5-SJ-1242-42 PIPE TO BRANCH CONNECTION
- 1.5-SJ-1232 CREF. DWG. NO. 202300 1.5-SJ-1232-3 BRANCH CONNECTION TO PIPE 202700 1.5-SJ-1232-10FB FLANGE BOLTING 202800 1.5-SJ-1232-12 PIPE TO VALVE 23SJ16 202850 1.5-SJ-1232-13 VALVE 23SJ16 TO PIPE A-101 SH B-J B9.40 B-J B9.40 B-J B9.40 B-J B9.40 A-103 SH B-J B9.40 B-G-2 B7.50 B-J B9.40 B-J B9.40 1) PT UT45 UT45T UT70 PT UT45 UT45T UT70 PT UT45 UT45T UT70 PT UT45 UT45T UT70 PT VT-2 PT PT VS2SSISZZ0075Q x w.o.#941023023 TO PERFORM NOE. A-E, PT VS2RAISZZ0087Q x --& UT PER NRC BULLETIN 88-08. II x II x VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. A-E, PT VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. II x --II x VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. A-E, PT VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. II x II x VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. A-E,, PT VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. II x II x VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE. SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE.
DATE: 04/19/95 SALEM NUCLEAR PO\.IER STATION UNIT 2 PAGE: 27 REVISION: 1 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3)
- SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H
SUMMARY
EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER !DENT! Fl CATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** ------------------------------
1.5-SJ-1232 {REF. DWG. NO. A-103 SH 22 203850 1.5-SJ-1232-33 B-J PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. A-E, PT VALVE 23SJ17 TO PIPE B9.40 UT45 VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. UT45T II x UT70 II x 203900 1.5-SJ-1232-34 B-J PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. A-E, PT PIPE TO ELBOW B9.40 UT45 VS2RAISZZ0087Q x -& UT PER NRC BULLETIN 88-08. UT45T II x UT70 II x 203950 1.5-SJ-1232-35 B-J PT VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE. A-E, PT ELBOW TO PIPE B9.40 UT45 VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. UT45T II x -UT70 II x
- 204000 1.5-SJ-1232-36 B-J PT VS2SSISZZ0075Q x -W.0.#94*1023023 TO PERFORM NOE. A-E, PT
- PIPE TO BRANCH CONNECTION 1.5-SJ-1222 (REF. DWG. NO. 204700 1.5-SJ-1222-13FB FLANGE BOLTING 205000 1.5-SJ-1222-19 PIPE TO VALVE 22SJ16 205050 1.5-SJ-1222-20 VALVE 22SJ16 TO PIPE B9.40 A-105 SH 12 B-G-2 B7.50 B-J B9.40 B-J B9.40 1.5-SJ-1222 CREF. DWG. NO. A-105 SH 22 205650 1.5-SJ-1222-32 PIPE TO ELBOW B-J B9.40 UT45 UT45T UT70 VT*2 PT PT PT VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. II x II x --SCSSISZZ0006Q x " W.0.#941023023 TO PERFORM NOE. VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE.
DATE: 04/19/95 REVISION: 1
- SAFETY INJECTION SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 28 1.5-SJ-1222 CREF. DWG. NO. A-105 SH 2> 205700 1.5-SJ-1222-33 ELBOW TO PIPE 206350 1.5-SJ-1222-46 VALVE 22SJ17 TO PIPE 206400 1.5-SJ-1222-47 PIPE TO ELBOW
- 206450 1.5-SJ-1222-48 ELBOW TO PIPE
- 206500 1.5-SJ-'1222-49 PIPE TO BRANCH CONNECTION 1.5-SJ-1212 CREF. DWG. NO. 206650 1.5-SJ-1212-3 BRANCH CONNECTION TO PIPE 206950 1.5-SJ-1212-SFB FLANGE BOLTING 207450 1.5-SJ-1212-18 PIPE TO VALVE 21SJ16 B-J B9.40 B-J B9.40 B-J B9.40 B-J B9.40 B-J B9.40 A-107 SH B-J B9.40 B-G-2 B7.50 B-J B9.40 1) PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. UT45 VS2RAISZZ0087Q x PERFORMED UT ANGLE CONFIRMATION.
A-E, UT45T II x PT & UT PER NRC BULLETIN 88-08. UT70 II x ANGLE CONF VS2RAISZZ0082Q x PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. A-E, PT UT45 VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. UT45T II x UT70 II x PT VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. A-E, PT UT45 VS2RAISZZ0087Q x --& UT PER NRC BULLETIN 88-08. UT45T II x UT70 II x PT VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE. A-E, PT UT45 VS2RAISZZ0087Q x & UT PER NRC BULLETIN 88-08. UT45T II x UT70 II x --PT VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE. VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. PT VS2SSISZZ0075Q X --W.0.#941023023 TO PERFORM NOE.
- *
- DATE: 04/19/95 REVISION:
1 SAFETY INJECTION SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 29 1.5-SJ-1212 CREF. DWG. NO. A-107 SH 1) 207500 1.5-SJ-1212-19 VALVE 21SJ16 TO PIPE 1.5-SJ-1212 CREF. DIJG. NO. 208250 1.5-SJ-1212-34 ELBOW TO PIPE 208700 1.5-SJ-1212-43 VALVE 21SJ17 TO PIPE 208750 1.5-SJ-1212-44 PIPE TO ELBOW 208800 1.5-SJ-1212-45 ELBOW TO PIPE 208850 1.5-SJ.-1212-46 PIPE TO BRANCH CONNECTION B-J B9.40 A-107 SH 2) B-J B9.40 B-J B9.40 B-J B9.40 B-J B9.40 B-J B9.40 PT VS2SSISZZ0075Gi PT VS2SSISZZ0075Q UT THICK VS2RAISZZ0088Q PT RE-EXAM VS2SSISZZ0075Q PT VS2SSISZZ0075Q UT45 VS2RAISZZ0087Q UT45T II UT70 II PT VS2SSISZZ0075Q UT45 VS2RAISZZ0087Q UT45T II UT70 II PT VS2SSISZZ0075Q UT45 VS2RAISZZ0087Q UT45T II UT70 II PT VS2SSISZZ0075Q UT45 VS2RAISZZ0087Q UT45T II UT70 II X --W.0.#941023023 TO PERFORM NOE. --x W.0.#941023023 TO PERFORM NOE. THE PT x --EXAM REVEALED 1 LINEAR RECORDABLE x INDICATION. DURING THE RELEVANCY DETERMINATION PROCESS, THE SURFACE CONDITIONING PROCEEDED A RE-EXAM WITH NO LINEAR INDICATIONS IDENTIFIED (REF. CNF#94002 & SEAT# 94-411) x IJ.0.#941023023 TO PERFORM NOE. A-E, PT x & UT PER NRC BULLETIN 88-08. x x x W.0.#941023023 TO PERFORM NOE. A-E, PT x --& UT PER NRC BULLETIN 88-08. x x x W.0.#941023023 TO PERFORM NOE. A-E, PT x & UT PER NRC BULLETIN 88-08. x --x x W.0.#941023023 TO PERFORM NOE. A-E, PT x & UT PER NRC BULLETIN 88-08. x --x
- DATE: 04/19/95 REVISION:
1 REACTOR COOLANT PUMPS
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE !SI EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOO PROCEDURE N 0 0 G
- T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 30 *BOLTING CREF. DWG. NO. A-109 SH 1) 250101 24-PMP-BOLTS 1-24 250201 23-PMP-BOLTS 1-24 250301 22-PMP-BOLTS 1-24 250401 21-PMP-BOLTS 1-24 PUMP MOTOR FLYWHEELS (REF. 252100 24-PMP-FLW FLYWHEEL A-E 82-02 A-E 82-02 A-E 82-02 A-E 82-02 VT-2 VT-2 VT-2 VT-2 DWG. NO. A-109 SH A-E UTOL RG 1.14 UT45 SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q
- 1) VS2RAISZZ0096Q II x --w.o.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. x W.0.#941023023 TO PERFORM NOE. EXAM -x -PERFORMED IN-PLACE. (S/N 1S-75P790)
UT45 GEOMETRIC REFLECTORS ARE FROM THE KEYWAYS. **42-SAM/50-SAM**
- DATE: 04/19/95 REVISION:
1 VALVES
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** BOLTING (REF. DWG. NO. A-10 SH 1) PAGE: 255000 2RC30 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1243 (FIG. A-10) B7.70 255050 2CV2 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1243 (FIG. A-10) B7.70 255100 2CV277 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1243 (FIG. A-10) B7.70 BOLTING DWG. NO. A-12 SH 1
- 255150 2CV79 BOLTING B-G-2 VT-2 SCSSISZZ0006Q x --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1241 (FIG. A-12) B7.70 255200 2CV275 BOLTING B-G-2 VT-2 SCSSISZZ0006Q x --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1241 (FIG. A-12) B7.70 255250 2CV80 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1241 (FIG. A-12) B7.70 BOLTING (REF. DWG. NO. A-13 SH 1) 255300 2CV77 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1231 (FIG. A-13) B7.70 255350 2CV274 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1231 (FIG. A-13) B7.70 255400 2CV78 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NOE. ON LINE 3-CV-1231 (FIG. A-13) B7.70 31 DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR PmlER STATION UNIT 2 PAGE: 32
- OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION CATGY EXAM ITEM NO METHOD BOLTING CREF. OWG. NO. A*15 SH 1) 255450 2CV75 BOLTING B*G*2 ON LINE 2-CV-1275 (FIG. A-15 87.70 SHT 1) BOLTING CREF. OWG. NO. A-17 SH 1) 255550 2PR5 BOLTING B-G-2 ON LINE 6*PR*1205 (FIG. A-17) 87.70 BOLTING CREF. OWG. NO. A-18 SH 1) 255600 2PR4 BOLTING B-G-2 ON LINE 6-PR-1204 (FIG. A-18) 87.70
- BOLTING CREF. DWG. NO. A-19 SH 1) 255650 2PR3 SOL Tl NG B-G-2 ON LINE 6-PR-1203 (FIG. A-19) B7.70 BOLTING CREF. DWG. NO. A-20 SH 1) 255675 2PR7 BOLTING B*G-2 ON LINE 3-PR-1207 A-20) 87.70 255700 2PR2 BOLTING B-G-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-1 PROCEDURE SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0010Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. x --w.o.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. x W.0.#941023023 TO PERFORM NOE. VT-1 WAS ON LINE 3-PR-1207 (FIG. A-20) 87.70 VT-2 SCSSISZZ0006Q x --PERFORMED, BUT NOT TAKEN CREDIT FOR AT THIS TIME. BOLTING CREF. OWG. NO. A-24 SH 1) 255725 2PR6 BOL Tl NG B-G-2 VT-2 SCSSISZZ0006Q x --W.0.#941023023 TO PERFORM NOE. ON LINE 3-PR-1206 (FIG. A-24) 87.70
- DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 33
- OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 1 CAKPRLE STATUS CGMPONENTS VALVES ASME SEC. XI
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION CATGY EXAM ITEM NO METHOD BOLTING DWG. NO. A-24 SH 12 255750 2PR 1 BOL Tl NG B-G-2 ON LINE 3-PR-1206 (FIG. A-24) B7.70 BOLTING DWG. NO. A-26 SH 22 255800 2PS28 BOLTING B-G-2 ON LINE 4-PS-1231 (FIG. A-26 B7.70 SHT 2) 255850 2PS3 BOLTING B-G-2 ON LINE 4-PS-1231 (FIG. A-26 B7.70 SHT 2)
- BOLTING DWG. NO. A-26 SH 32 255900 2PS29 BOLTING B-G-2 ON LINE 4-PS-1231 (FIG. A-26 B7.70 SHT 3) BOLTING CREF. DWG. NO. A-28 SH 12 255950 2PS24 BOL Tl NG B-G-2 ON LINE 4-PS-1211 CF-IG. A-28) B7.70 255975 2PS1 BOLTING B-G-2 ON LINE 4-PS-1211 (FIG. A-28) B7.70 256000 2PS25 BOL Tl NG B-G-2 ON LINE 4-PS-1211 (FIG. A-28) B7.70 BOLTING (REF. DWG. NO. A-61 SH 12 *257850 2RH1 BOLTING B-G-2 ON LINE 14-RH-1211 (FIG. A-61) B7.70 VT-1 VT-2 VT-2 VT-1 VT-2 VT-2 VT-2 VT-1 VT-2 VT-2 VT-2 PROCEDURE SCSSISZZ0010Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0010Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0010Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** x W.0.#941023023 TO PERFORM NDE. VT-1 WAS x --PERFORMED, BUT NOT TAKEN CREDIT FOR AT THIS TIME. x --W.0.#941023023 TO PERFORM NDE. x --PSI BASELINE PERFORMED PER PS-94-010 I x --940224127 I 2EC-3220 (REPLACED All BOLTING WITH SS)
- x --W.0.#941023023 TO PERFORM NDE. X --W.0.#941023023 TO PERFORM NDE. x --PSI BASELINE PERFORMED PER PS-94-009 I x --940224123 I 2EC-3220 (REPLACED BOLTING WITH SS). x --W.0.#941023023 TO PERFORM NDE. X --W.0.#941023023 TO PERFORM NDE.
DATE: 04/19/95 REVISION: 1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 34 .VALVES OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ITEM NO METHOD BOLTING (REF. DWG. NO. A-61 SH 1) 257900 2RH2 BOLTING B-G-2 ON LINE 14-RH-1211 (FIG. A-61) B7.70 BOLTING (REF. DWG. NO. A-62 SH 1) 257950 2RH26 BOLTING B-G-2 ON LINE 12-RH-1251 (FIG. A-62) B7.70 BOLTING (REF. DWG. NO. A-63 SH 1) .258000 24SJ54 BOLTING B-G-2 ON LINE 10-SJ-1241 (FIG. A-63) B7.70 258050 24SJ55 BOLTING B-G-2 ON LINE 10-SJ-1241 (FIG. A-63) B7.70 258100 24SJ56 BOLTING B-G-2 ON LINE 10-SJ-1241 (FIG. A-63) B7.70 BOLTING (REF. DWG. NO. A-64 SH 1) 258150 23SJ54 BOLTING B-G-2 ON LINE 10-SJ-1231 (FIG. A-64) B7.70
- VT-2 VT-2 VT-3 VT* 1COLD) VT-1CNEW)
MT VT-2 VT-3 VT-2 VT-2 VT-2 VT-3 PROCEDURE SCSSISZZ0006Q SCSSISZZ0006Q S2SSISZZ0009Q SCSSISZZ0010Q SCSSISZZ0010Q SHRAISZZ0201Q SCSSISZZ0006Q S2SSISZZ0009Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q S2SSISZZ0009Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.#941023023 TO PERFORM NOE. x W.0.#941023023 TO PERFORM NOE. BORIC x ACID WAS FOUND ON THE BOLTED CONNECTION. x AR#941025111 WAS WRITTEN TO REMOVE AS x NECESSARY THE AFFECTED BOLTING. PSI x BASELINE PERFORMED PER S-94-190 I 940926176 (MISC. NEW BOLTING). x W.0.#941023023 TO PERFORM NOE. BORIC x --ACID WAS FOUND ON THE BOLTED CONNEC110N. AR#9411011159 WAS WRITTEN TO REMOVE AS NECESSARY THE AFFECTED BOLTING. 1 STUD WAS REMOVED AND A SATISFACTORY VT-3 WAS PERFORMED. x --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. x x W.0.#941023023 TO PERFORM NOE. BORIC ACID WAS FOUND ON THE BOLTED CONNECTION. AR#941101158 WAS WRITTEN TO REMOVE AS NECESSARY THE AFFECTED BOLTING. A SATISFACTORY VT-3 WAS PERFORMED ON STUD
- DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE:
- OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS VALVES ASHE SEC. XI
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION CATGY EXAM ITEM NO METHOO BOLTING CREF. DWG. NO. A-64 *SH 1) 258200 23SJ55 BOLTING B-G-2 ON LINE 10-SJ-1231 (FIG. A-64) B7.70 258250 23SJ56 BOLTING B-G-2 ON LINE 10-SJ-1231 (FIG. A-64) B7.70 BOLTING CREF. DWG. NO. A-65 SH 1) 258300 22SJ54 BOLTING B-G-2 ON LINE 10-SJ-1221 (FIG. A-65) B7.70 *25.8350 22SJ55 BOLTING B-G-2 ON LINE 10-SJ-1221 (FIG. A-65) B7.70 258400 22SJ56 BOLTING B-G-2 ON LINE 10-SJ-1221 (FIG. A-65) B7.70 BOLTING (REF. DWG. NO. A-66 SH 1) 258450 21SJ54 BOLTING B*G-2 ON LINE 10*SJ*1211 (.FIG. A-66) B7.70 258500 21SJ55 BOLTING B-G-2 ON LINE 10-SJ-1211 (FIG. A-66) B7.70 258550 21SJ56 BOLTING B-G-2 ON LINE 10-SJ-1211 (FIG. A-66) B7.70 BOLTING CREF. DWG. NO. A-67 SH 1) *258600 22SJ49 BOLTING B-G-2 ON LINE 8*SJ*1262 (FIG. A-67 B7.70 SHT 1) VT-2 VT-2 VT-2 VT*2* VT-2 VT-2 VT-2 VT-2 VT-2 PROCEDURE SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q N 0 0 G T R E H E* 0 E REMARKS C M R **CALIBRATION BLOCK** X *
- W.0.#941023023 TO PERFORM NOE. X * -W.0.#941023023 TO PERFORM NOE. X *
- W.0.#941023023 TO PERFORM NOE. X *
- W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. X * -W.0.#941023023 TO PERFORM NOE. X -* W.0.#941023023 TO PERFORM NOE. X *
- W.0.#941023023 TO PERFORM NOE. X *
- W.0.#941023023 TO PERFORM NOE. 35 DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 36 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASHE SEC. XI
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION CATGY EXAM ITEM NO METHOD BOLTING CREF. DWG. NO. A*69 SH 1) 258650 21SJ49 BOLTING B-G-2 B7.70 ON LINE 8-SJ-1252 (FIG. A-69 SHT 1) BOLTING CREF. DWG. NO. A-71 SH 1) 258700 24RH27 BOLTING B-G-2 ON LINE 8-SJ-1245 (FIG. A-71) B7.70 BOLTING CREF. DWG. NO. A-62 SH 1) 258750 23RH27 BOL Tl NG B-G-2 ON LINE 8-RH-1235 (FIG. A-62) B7.70
- BOLTING CREF. DWG. NO. A-73 SH 1> 258800 24SJ43 BOLTING B-G-2 ON LINE 6-SJ-1242 (FIG. A-73) B7.70 BOL r'ING (REF. DWG. NO. A-74 SH 1) 258850 24SJ156 BOLTING B-G-2 ON LINE 6-SJ-1241 CF-IG. A-74) B7.70 BOLTING CREF. DWG. NO. A-76 SH 1) 258900 23SJ43 BOLTING B-G-2 ON LINE 6-SJ-1232 (FIG. A-76) B7.70 BOLTING CREF. DWG. NO. A-77 SH 1) .258950 23SJ156 BOLTING B-G-2 ON LINE 6-RH-1231 (FIG. A-77) B7.70 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-3 VT-2 PROCEDURE SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q S2SSISZZ0009Q SCSSISZZ0006Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** x --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. x -W.0.#941023023 TO PERFORM NOE. x W.0.#941023023 TO PERFORM NOE. BORIC x -ACID WAS FOUND ON THE BOLTED CONNECTION.
W.0.941104087 WAS WRITTEN TO REMOVE AS NECESSARY THE AFFECTED BOLTING. W.0#941104087, REMOVED 1 STUD, AND A SATISFACTORY VT-3 WAS PERFORMED. x --W.0.#941023023 TO PERFORM NOE. DATE: 04/19/95 REVISION: 1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: .VALVES OUTAGE ISi EXAMINATION RESULTS REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS
- ASME SEC. XI
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION CATGY EXAM
- ITEM NO METHOD BOLTING (REF. DWG. NO. A-79 SH 1) 259000 22SJ43 BOLTING B-G-2 VT-2 ON LINE 6*SJ-1222 (FIG. A-79) B7.70 BOLTING CREF. DWG. NO. A*80 SH 1) 259050 22SJ156 BOLTING B-G-2 VT-2 ON LINE 6-SJ-1221 (FIG. A-80) B7.70 BOLTING {REF. DWG. NO. A-81 SH 259100 21SJ43 BOLTING B-G-2 VT-2 ON LINE 6-SJ-1212 (FIG. A-81) B7.70 BOLTING CREF. DWG. NO. A-99 SH 2) 259150 21SJ156 BOLTING B-G-2 VT-2 ON LINE 6-SJ-1211 (FIG. A-99) B7.70 BOLTING CREF. OWG. NO. A-84 SH 1) 259200 2SJ13 BOLTING B-G-2 VT-2 ON LINE 4-SJ-1295 CFIG. A-84) B7.70 BOLTING CREF. OWG. NO. A-85 SH 1) 259250 2SJ135 BOLTING B-G-2 VT-2 ON LINE 4-SJ-1294 (FIG. A-85) B7.70 BOLTING CREF. OWG. NO. A-84 SH 1) 259300 2SJ12 BOLTING B-G-2 VT-2 ON LINE 4-SJ-1293 (FIG. A-84) B7.70
- PROCEDURE SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q SCSSISZZ0006Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. x --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. 37
- DATE: 04/19/95 REVISION:
1 VALVES
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISI EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G" T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** BOLTING CREF. DWG. NO. A-86 SH 1) PAGE: 259350 22SJ40 BOLTING B*G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NDE. ON LINE 4-SJ-1282 (FIG. A-86) B7.70 BOLTING CREF. DWG. NO. A-87 SH 1) 259400 21SJ40 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NDE. ON LINE 4-SJ-1272 (FIG. A-87) B7.70 BOLTING CREF. DWG. NO. A-84 SH 1) 259450 2SJ150 BOLTING B-G-2 VT-2 SCSSISZZ0006Q X --W.0.#941023023 TO PERFORM NDE. ON LINE 3-SJ-1292 (FIG. A-84) B7.70 *
- 38
- DATE: 04/19/95 REVISION:
1 STEAM GENERATORS
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 39 CIRCUMFERENTIAL WELOS CREF. DWG. NO. B-3 SH 1) 270400 22-STG-TSSTB TUBE SHEET TO STUB BARREL 271600 22-STG-SBTC SHELL B TO TRANSITION CONE *
- C-A C1.30 C-A C1 .10 UTOL UTOW UT45 UT45T UT60 UT60T UTOL UTOW UT45 UT45T UT60 UT60T PROFILE VS2RAISZZ0088Q x II x VS2RAISRCE0084Q
-II x II x II x VS2RAISZZ0088Q x II x VS2RAISRCE0084Q x II x II x II x II --x ---W.0.#941023023 TO PERFORM NOE. EXAMINE 100% OF THE WELD. UT45 GEOMETRIC REFLECTORS ARE FROM THE TUBE SHEET RADIUS. **42-SAM/51-SAM** W.0.#941023023 TO PERFORM NOE. EXAMINED 100% OF THE WELD. **51-SAM** DATE: 04/19/95 SALEM NUCLEAR POYER STATION UNIT 2 PAGE: 40 REVISION: 1 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3)
- SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) RESIDUAL HEAT REMOVAL HEAT EXCHANGER CLASS 2 CAKPRLE STATUS COMPONENTS
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASME SEC. XI CATGY EXAM ITEM NO METHOD NOZZLE WELDS CREF. DWG. NO. B-11 SH 1)
- 275400 21-RHRHEX-OUT NOZZLE-TO-SHELL WELD
- C-B C2.21 PT UT45 UT60 PROFILE N 0 0 G T R E H E 0 E REMARKS PROCEDURE C M R **CALIBRATION BLOCK** VS2SSISZZ0075Q x W.0.#941023023 TO PERFORM NOE. VS2RAISZZ0086Q x LIMITATION:
UT EXAM LIMITED TO 45% CODE II x --COVERAGE, DUE TO.NOZZLE CONFIGURATION VS2RAISZZ0088Q AND AS YELDED CONDITION.
- 85-SAM**
- DATE: 04/19/95 REVISION:
1 FEEDWATER SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 41 16-BF-2241 (REF. DWG. NO. B-13 SH 1) 330261 16-BF-2241-1 REDUCER TO NOZZLE A*E UT45 IN93*20 UT45T UT60 14-BF-2231 (REF. DWG. NO. B*14H SH 1) 330330 14-BF-2231-4PS PIPE SUPPORT c-c C3.20 14-BF-2231 CREF. DWG. NO. B*14 SH 1) 14-BF-2231*14PL-1&2 PIPE LUG 330510 14-BF-2231-15PL-9&10 PIPE LUG 330515 14-BF-2231-15PL-11 THRU 18 2-FWH-23-24 330525 14-BF-2231-16 PIPE TO PIPE 14-BF-2231 (REF. DWG. NO. 330540 14-BF-2231-17PS PIPE SUPPORT S-22
- c-c C3.20 c-c C3.20 c-c C3.20 C-F-2 CS.51 B-14H SH 1) c-c C3.20 MT MT MT MT MT UT45 UT45 OL UT45T MT VS2RAISZZ0082Q II II VS2SSISZZ0070Q VS2SSISZZ0070Q VS2SSISZZ0070Q VS2SSISZZ0070Q VS2SSISZZ0070Q VS2RAISZZ0082Q II II II VS2SSISZZ0070Q -X -W.0.#941023023 TO PERFORM NOE. X REFERENCE NUCLEAR ENGINEERING LETTER -X -MEC*94-187, WHICH DELINATES THE REQUIRED INSPECTIONS FOR S2RF0#8. UT45&60 GEOMETRIC REFLECTORS ARE FROM THE WELD ROOT. **116-SAM**
X *
- W.0.#941023023 TO PERFORM NOE. X -* W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. X --W.0.#941023023 TO PERFORM NOE. x W.0.#941023023 TO PERFORM NOE. UT45 -x -GEOMETRIC REFLECTOR IS FROM THE INSIDE . x -SURFACE. THIS INDICATION COULD BE SEEN x --INTERMITTENTLY 360 DEGREES, BUT COULD x NOT .BE SEEN FROM THE DOWNSTEAM SIDE. **35-SAM**
x --W.0.#941023023 TO PERFORM NOE. LIMITATION: LIMITED TO SOX CODE COVERAGE, DUE TO THE PROXIMITY OF A PERMANENT PIPE RESTRAINT
- DATE: 04/19/95 REVISION:
1 .FEEDWATER SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION
SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS N 0 ASME 0 G T SEC. XI R E H CATGY EXAM E 0 E REMARKS ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** PAGE: 42 ----------
14-BF-2231 CREF. DWG. NO. B-14H SH 1) 330560 14-BF*2231-18PS c-c MT VS2SSISZZ0070Q x --W.0.#941023023 TO PERFORM NOE. PIPE SUPPORT C3.20 LIMITATION: EXAM LIMITED TO 50% CODE COVERAGE, DUE TO PROXIMITY OF A PERMANENT PIPE COLLAR. 14*BF-2231 CREF. DWG. NO. B-14 SH 1> 330600 14-BF-2231-22 C-F-2 MT VS2SSISZZ0070Q x --*w.0.#941023023 TO PERFORM NDE. UT45 ELBOW TO REDUCER CS.51 UT45 VS2RAISZZ0082Q -x -GEOMETRIC REFLECTORS ARE FROM THE WELD ROOT & INSIDE SURFACE. **35-SAM** 16-BF-2221 CREF. DWG. NO. B-16 SH 1) 330911 16-BF-2221-1 A-E UT45 VS2RAISZZ0082Q -x -W.0.#941023023 TO PERFORM NDE.
- REDUCER TO NOZZLE IN93-20 UT45T II x --REFERENCE NUCLEAR ENGINEERING LETTER UT60 II -x -MEC-94-187, WHICH DELINATES THE REQ4IRED INSPECTIONS FOR S2RF0#8. UT45&60 GEOMETRIC REFLECTORS ARE FROM THE WELD ROOT. **116-SAM**
- DATE: 04/19/95 REVISION:
1 .RESIDUAL HEAT REMOVAL SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 43 8-CS-2225 CREF. DWG. NO. B-18 SHT 2> 350050 8-CS-2225-5 ELBOW TO VALVE 22CS36 *
- C-F-1 ANGLE CONF VS2RAISZZ0082Q A-E<3/8 -X --W.0.#941023023 TO PERFORM NOE. PERFORM UT ANGLE CONFIRMATION, TO SATISFY S2RF0#7'S EXAMS. CHANGED COMPONENT ID FROM 8-RH-2225-5 TO 8-CS-2225-5, DUE TO HAVING A DUPLICATE COMPONENT ID. **44-SAM**
- DATE: D4/19/95 REVISION:
1 CONTAINMENT SPRAY SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POYER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 44 8-CS-2225 CREF. DYG. NO. B-18 SHT 2) 350054 2P-CSG-309 GUIDE F-A VT-3 A-E<3/8 S2SSISZZ0011Q 8-CS-2225 tPSE&G #8 11-2CS1010J CREF. DYG. NO. B-18 SHT 2)
- 350103 8-CS-2225-28 FLANGE TO PIPE 350104 8-CS-2225-29 PIPE TO FLANGE C-F-1 A-E<3/8 C-F-1 A-E<3/8 RT VSHSSSPZZ0210Q PT VSHSSSPZZ0204Q RT VSHSSSPZZ0210Q PT VSHSSSPZZ0204Q 8-RH-2215
[PSE&G #8 11-2SJ-1424J (REF. DYG. NO. B-18 SHT 1) 350125 2P-CSH-310 VAR.SUPPORT,TYP.D,SZ12,CL-2138,HL-1663
- F-A VT-3 S2SSISZZ0011Q A-E<3/8 X --PSI BASELINE PERFORMED PER PS-94-039 I 940824090 I 2EC-3275-1 (MODIFICATION, DUE TO ENGR. REANALYSIS).
x UNDER DCP 2EC-3173, W.0.# 940418179 AND x CJP# PS-93-092, VALVE 21 & 22CS6 WAS ADDED BACK INTO THE CONTAINMENT SPRAY LINES. THE ISi BOUNDARY IS NOW EXTENDED UP TO THIS VALVE. DURING S2RF0#9 THIS WELD WILL RECEIVE A NEW PSI EXAM. **44-SAM** x UNDER DCP 2EC-3173, W.0.# 940418179 AND x --CJP# PS-93-092, VALVE 21 & 22CS6 WAS ADDED BACK INTO THE CONTAINMENT SPRAY LINES. THE ISi BOUNDARY IS NOW EXTENDED UP TO THIS VALVE. DURING S2RF0#9 THIS WELD WILL RECEIVE A NEW PSI EXAM. **44-SAM** X --PSI BASELINE PERFORMED PER PS-94-039 I 940824090 I 2EC-3275-1 (MODIFICATION, DUE TO ENGR. REANALYSIS)
- DATE: 04/19/95 REVISION:
1 .MAIN STEAM SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT OUTAGE ISI EXAMINATION RESULTS REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 45 34-MS-2241 [PSE&G #34 11-2MS1020J CREF. DWG. NO. B-38 SH 1) 380140 34-MS-2241-3
- C-F-2 MT VS2SSISZZ0070Q PIPE TO VALVE 24MS167 C5.51 MT II UT45 VS2RAISZZ0082Q UT45T II PROFILE VS2RAISZZ0088Q 34-MS-2241
[PSE&G #34 11-2MSi019J CREF. DWG. NO. B-38 SH 1) 381070 34-MS-2241-242PL PIPE LUG 242 c-c C3.20 MT VS2SSISZZ0070Q
- 6-MS-2211
[PSE&G #6 11-2MS1056J CREF. DWG. NO. B-45 SH 1) 385510 6-MS-2211-13 TEE TO PIPE
- C-F-2 C5.51 MT UT45 VS2SSISZZ0070Q VS2RAISZZ0082Q PROFILE VS2RAISZZ0088Q UT THICK VS2RAISZZ0088Q MT RE-EXAM VS2SSISZZ0070Q x W.0.#941023023 (NOE). EXAM TO INCLUDE x 2.5T OF INTERSECTING LG SEAM ON UP STRM -x -SIDE OF WELD. UT45 GEOMETRIC REFLECTOR
-x -IS FROM THE WELD COUNTERBORE & BRANCH CONNECTION INSIDE RADIUS. LIMITATION: UT EXAM LIMITED TO 85% CODE COVERAGE.
- 51-SAM (ALT#01)** X --W.0.#941023023 TO PERFORM NOE. LIMITATION:
MT EXAM LIMITED TO 71% CODE COVERAGE ON LUG #2, DUE TO INACCESSIBILTY (PERMANENT BEAM OBSTRUCTION). --X W.0.#941023023 TO PERFORM NOE. THE MT X EXAM REVEALED 1 LINEAR RECORDABLE INDICATION. DURING THE RELEVANCY X DETERMINATION PROCESS, SURFACE X --CONDITIONING PROCEEDED A RE-EXAM WITH NO LINEAR INDICATIONS IDENTIFIED (REF. CNF# 94-015 & LTR ISI-S-94-045
- 49-SAM**
DATE: 04/19/95 REVISION: 1
- PRESSURIZER RELIEF SYSTEM
SUMMARY
EXAMINATION AREA NUMBER !DENT! Fl CATION ------------------------------------- 6-PR-2205 DWG. NO. 500412 2-PRG-52 GUIDE 500416 2-PRG-51 GUIDE 500441 2C-PRH-212
- 6-PR-2204 (REF. DWG. NO. B-50) 500612 2-PRG-40 GUIDE 500633. 2-PRG-9 GUIDE 500635 2C-PRH-211 500640 2C-PRH-211A 6-PR-2203 (REF. DWG. NO. B-51) 500812 2-PRG-26 GUIDE
- SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 46 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) ASME SEC. XI CATGY ITEM NO F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 CLASS 2 CAKPRLE STATUS*COMPONENTS EXAM METHOD PROCEDURE
*-
VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3C1ST> S2SSISZZ0011Q VT-3(2ND) S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q N 0 0 G* T R E H E 0 E REMARKS c M R **CALIBRATION BLOCK** ---------------------------------------- x --PSI BASELINE PERFORMED PER 2EC-3348-1 I PS-95-004 I 950112164 (MOD., DUE TO 2PR3,4&5 VLV LKG). x --PSI BASELINE PERFORMED PER 2EC-3348-1 I PS-95-004 I 950112164 (MOD., DUE TO 2PR3,4&5 VLV LKG). x PSI BASELINE PERFORMED PER 2EC-3346-1 I x PS-95-003 I 950112136 (MOD., DUE TO 2PR3,4&5 VLV LKG). ANOTHER PSI BASELINE PERFORMED PER 2EC-3348-1 I PS-95-004 I 950112164 (MOD., DUE TO 2PR3,4&5 VLV LKG)
- x --PSI BASELINE PERFORMED PER 2EC-3348-1 I PS-95-004 I 950112164 (MOD. , DUE TO 2PR3,4&5 VLV LKG). x --PSI BASELINE PERFORMED PER 2EC-3348-1 I PS-95-004 I 950112164 (MOO. , DUE TO 2PR3,4&5 VLV LKG). x --PSI BASELINE PERFORMED PER 2EC-3346-1 I PS-95-003 I 950112136 (MOO., DUE TO 2PR3,4&5 VLV LKG). X --PSI BASELINE PERFORMED PER 2EC-3346-1 I PS-95-003 I 950112136 (MOD., DUE TO 2PR3,4&5 VLV LKG). X --PSI BASELINE PERFORMED PER 2EC-3348-1 I PS-95-004 I 950112164 (MOD., DUE TO 2PR3,4&5 VLV LKG) * .
- DATE: 04/19/95 REVISION:
1 PRESSURIZER RELIEF SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION 6-PR-2203 CREF. DWG. NO. B-51> 500816 2-PRG-27 GUIDE 500865 2C-PRH-209
- SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 47 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD F-A F1.20 F-A F1.20 VT-3 VT-3 PROCEDURE S2SSISZZ0011Q S2SSl-SZZ0011Q N 0 0 G T R E H E 0 E REMARKS C H R **CALIBRATION BLOCK** X --PSI BASELINE PERFORMED PER 2EC-3348-1 I PS-95-004 I 950112164 CHOO., DUE TO 2PR3,4&5 VLV LKG). X --PSI BASELINE PERFORMED PER 2EC-3346-1 I PS-95-003 I 950112136 (MOO., DUE TO 2PR3,4&5 VLV LKG)
- DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 48 ** OUTAGE !SI EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 2 CAKPRLE STATUS COMPONENTS
- RESIDUAL HEAT REMOVAL SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE 14-RH-2224 [PSE&G #14"-2RH1002l (REF. DWG. NO. B-54 SH 1) 501410 14-RH-2224-1 TEE TO ELBO\I 501473 14-RH-2224-7A PIPE TO VALVE 2RH76 501477 14-RH-2224-7B VALVE 2RH76 TO PIPE C-F-1 C5.11 C-F-1 C5.11 C-F-1 C5.11 PT UT45 UT45T PT UT45 UT45T PROFILE PT UT45 UT45T PROFILE VS2SSISZZ0075Q VS2RAISZZ0082Q " VS2SSISZZ0075Q VS2RAISZZ0082Q " VS2RAISZZ0088 VS2SSISZZ0075Q VS2RAISZZ0082Q " VS2RAISZZ0088Q 14-RH-2214 [PSE&G #14"-2RH1002J (REF. DWG. NO. B-55 SH 1) 501610 14-RH-2214-1 TEE TO PIPE 501693 14-RH-2214-9A PIPE TO VALVE 2RH75 501765 14-RH-2214-16PS-1 THRU 4 PIPE SUPPORT C-F-1 cs. 11 C-F-1 CS.11 c-c C3.20 PT UT45 UT45T PT UT45 UT45T PROFILE PT VS2SSISZZ0075Q VS2RAISZZ0082Q II VS2SSISZZ0075Q VS2RAISZZ0082Q " VS2RAISZZ0088Q VS2SSISZZ0075Q 14-RH-2212 CPSE&G #14 11-2RH1001] (REF. DWG. NO. B-56 SH 1) .* 501800 14-RH-2212-1 VALVE 2RH2 TO PIPE C-F-1 PT VS2SSISZZ0075Q CS.11 UT45 VS2RAISZZ0082Q UT45T II UT45TAN II PROFILE VS2RAISZZ0088Q ANGLE CONF VS2RAISZZ0082Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** x x x W.0.#941023023 TO PERFORM NOE. EXAMINATION TO INCLUDE 2.5T OF THE INTERSECTING LONGITUDINAL SEAM ON THE BOTH SIDES OF THIS WELD. **79-SAM** X W.0.#941023023 TO PERFORM NOE. -X -EXAMINATION TO INCLUDE 2.ST OF THE X --INTERSECTING LONGITUDINAL SEAM ON THE UP STREAM SIDE OF THIS WELD. THE UT45 EXAM FOUND GEOMETRIC REFLECTORS FROM THE INSIDE SURFACE. **79-SAM** X W.0.#941023023 TO PERFORM NOE. X EXAMINATION TO INCLUDE 2.ST OF THE X --INTERSECTING LONGITUDINAL SEAM ON THE DOWN STREAM SIDE OF THIS WELD. **79-SAM** x x x W.0.#941023023 TO PERFORM NOE. EXAMINATION TO INCLUDE 2.ST OF THE INTERSECTING LONGITUDINAL SEAM ON BOTH SIDES OF THIS WELD. **79-SAM** X W.0.#941023023 TO PERFORM NOE. X --EXAMINATION TO INCLUDE 2.ST OF THE x INTERSECTING LONGITUDINAL SEAM ON THE UP STREAM SIDE OF THIS WELD. **79-SAM** X --W.0.#941023023 TO PERFORM NOE. x W.0.#941023023. UT ANGLE CONF. FOR -x -S2RF0#7'S EXAMS. EXAM TO INCLUDE 2.ST x OF INTERSECTING LG SEAM ON THE ON STREAM x SIDE OF WELD. LIMITATION: UT EXAM LIMITED TO 87% CODE COVERAGE, DUE TO VLV x CONFIGURATION. UT45 GEOMETRIC REFLECTOR iii WELD ROOT. DATE: 04/19/95 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 49 REVISION: 1 .RESIDUAL HEAT REMOVAL SYSTEM OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASHE SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE 14-RH-2212 CPSE&G #14 11-2RH1001l CREF. DWG. NO. B-56 SH 1) 501900 14-RH-2212-10 PIPE TO ELBOW 501910 14-RH-2212-11 ELBOW TO PIPE C-F-1 C5.11 C-F-1 C5.11 PT VS2SSISZZ007SQ UT45 VS2RAISZZ0082Q UT45T II UT45TAN II PROFILE VS2RAISZZ0088Q PT VS2SSISZZ0075Q UT45 VS2RAISZZ0082Q UT45T II UT45TAN II PROFILE VS2RAISZZ0088Q ANGLE CONF VS2RAISZZ0082Q 8-RH-2226 CPSE&G #8 11-2RH1003] (REF. DWG. NO. B-61 SH 1) *502895 8-RH-2226-9PL-1&2 PIPE LUG c-c C3.20 PT VS2SSISZZ0075Q 14-SJ-2224 CPSE&G #14 11-2RH1034J (REF. DWG. NO. B-65 SH 1) 570010 14-SJ-2224-1 C-F-1 PT. VS2SSISZZ0075Q VALVE 22SJ44 TO ELBOW C5.11 UT45 VS2RAISZZ0082Q UT45T II UT45TAN II PROFILE VS2RAISZZ0088Q 14-RH-2214 CPSE&G #14 11-2RH1035] (REF. DWG. NO. 8-65 SH 1) 571120 14-RH-2214-12 ELBOW TO TEE C-F-1 C5.11 PT UT45 UT45T PROFILE VS2SSISZZ0075Q VS2RAISZZ0082Q II VS2RAISZZ0088Q 12-RH-2269 CPSE&G #12 11-2RH1001J CREF. DWG. NO. B-67 SH 1) *572030 12-RH-2269-3 ELBOW TO PIPE C-F-1 CS.11 PT UT45 UT45T VS2SSISZZ0075Q VS2RAISZZ0082Q II N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** x w.o.#941023023 TO PERFORM NOE. x EXAMINATION TO INCLUDE 2.5T OF THE x INTERSECTING LONGITUDINAL SEAM ON BOTH x SIDES OF THIS WELD. **79-SAM** x W.0.#941023023 TO PERFORM NOE. x EXAMINATION TO INCLUDE 2.5T OF THE x --INTERSECTING LONGITUDINAL SEAM ON BOTH x SIDES OF THIS WELD. PERFORMED UT ANGLE CONFIRMATION. x **79-SAM** X --W.0.#941023023 TO PERFORM NOE. x W.0.#941023023 TO PERFORM NOE. x EXAMINATION TO INCLUDE 2.5T OF THE x INTERSECTING LONGITUDINAL SEAM ON THE x DOWN STREAM SIDE OF THIS WELD. LIMITATION: UT EXAM IS LIMITED TO 75% CODE COVERAGE, DUE TO THE VALVE CONFIGURATION.
- 79-SAM**
X W.0.#941023023 TO PERFORM NOE. -X -EXAMINATION TO INCLUDE 2.5T OF THE x INTERSECTING LONGITUDINAL SEAM ON BOTH SIDES OF THIS WELD. UT45 FOUND GEOMETRIC REFLECTORS FROM THE WELD ROOT. **79-SAM** X W.0.#941023023 TO PERFORM NOE. X EXAMINATION TO INCLUDE 2.5T OF THE X --INTERSECTING LONGITUDINAL SEAM ON BOTH SIDES OF THIS WELD. **31-SAM** DATE: 04/19/95 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 50 REVISION: 1 .RESIDUAL HEAT REMOVAL SYSTEM OUTAGE ISI EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE 12-RH-2269 tPSE&G #12 11-2RH1001l (REF. DWG. NO. B-67 SH 1) 572035 12-RH-2269-3PL-1&2 PIPE LUG c-c C3.20 12-RH-2252 [PSE&G #12 11-2RH1049] (REF. 573010 12-RH-2252-1 C-F-1 REDUCER TO TEE C5.11 PT VS2SSISZZ0075Q DWG. NO. B-68 SH 1) PT VS2SSISZZ0075Q UT45 VS2RAISZZ0082Q UT45T II PROFILE VS2RAISZZ0088Q ANGLE CONF VS2RAISZZ0082Q
- 573140 12-RH-2252
[PSE&G #12 11-2RH1006] CREF. DWG. NO . B-68 SH 1) 12-RH-2252-14 C-F-1 PT VS2SSISZZ0075Q PIPE TO ELBOW C5.11 UT45 VS2RAISZZ0082Q UT45T II PROFILE VS2RAISZZ0088Q 573380 12-RH-2252-38 C-F-1 PT VS2SSISZZ0075Q PIPE TO PIPE C5.11 UT45 VS2RAISZZ0082Q UT45T II UT45TAN II PROFILE VS2RAISZZ0088Q ANGLE CONF VS2RAISZZ0082Q 12-RH-2252 [PSE&G #12 11-2RH1006] CREF. DWG. NO. B-68H SH 1) 573383 12-RH-2252-38PS-1&2 c-c PT 38PS-1 VS2SSISZZ0075Q PIPE SUPPORT C3.20 PT 38PS-2 II 573387 12-RH-2252-38PS-3 c-c PT VS2SSISZZ0075Q PIPE SUPPORT C3.20
- N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.#941023023 TO PERFORM NOE. x W.0.#941023023 TO PERFORM NOE. PERFORM -x -UT ANGLE CONFIRMATION, TO SATISFY x S2RF0#7'S EXAMS. EXAMINATION TO INCLUDE 2.5T OF THE INTERSECTING LONGITUDINAL x SEAM ON BOTH SIDES OF THIS WELD. UT45 FOUND GEOMETRIC REFLECTORS FROM THE WELD ROOT. **66-SAM**
x -W.0.#941023023 TO PERFORM NOE. x EXAMINATION TO INCLUDE 2.5T OF THE x --INTERSECTING LONGITUDINAL SEAM ON BOTH SIDES OF THIS WELD. **31-SAM** x W.0.#941023023 (NOE). EXAM TO INCLUDE x 2.5T OF THE INTERSECTING LG SEAM ON BOTH x SIDES OF WELD. PERFORMED UT ANGLE x CONFIRMATION. LIMITATION: UT EXAM IS LIMTED TO 67% CODE COVERAGE, DUE TO A x WELDED PLUG & PROXIMITY OF ADJACENT PIPING. **31-SAM** x W.0.#941023023 TO PERFORM NOE. x LIMITATION: PT EXAM OF 38PS-1 WAS LIMITED TO 71% CODE COVERAGE, DUE TO THE PROXIMITY OF A PERMANENT SUPPORT. x --W.0.#941023023 TO PERFORM NOE. LIMITATION: PT EXAM IS LIMITED TO 71% CODE COVERAGE, DUE TO THE PROXIMITY OF ADJACENT PIPING. DATE: 04/19/95 REVISION: 1 .RESIDUAL HEAT REMOVAL SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 51 -------------------------------------
8-RH-2225 tPSE&G #8 11-2RH1031l CREF *. DWG. NO. B-74) 576115 2A-RHRS-252 SUPPORT F-A F1.20 VT-3 8-RH-2215 tPSE&G #8 11-2RH1029] CREF. DWG. NO. B-75) 577166 2A-RHRG-246 GUIDE *
- F-A F1.20 VT-3 S2SSISZZ0011Q S2SSISZZ0011Q X --PSI BASELINE PERFORMED PER PS-94-037 I 940805168 I 2EC-3275-1 (MODIFICATION, DUE TO ENGR.REANALYSIS). X --PSI BASELINE PERFORMED PER PS-94-037 I 940805168 I 2EC-3275-1 (MODIFICATION, DUE TO ENGR.REANALYSIS)
- . 1
- DATE: 04/19/95 REVISION:
1 SAFETY INJECTION SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 52 6-SJ-2204 CPSE&G #6 11-2SJ10081 (REF. DWG. NO. B-77 SH 1>
- 578100 6-SJ-2204-1 REDUCER TO ELBOIJ
- C-F-1 C5.11 PT UT45 UT45T ANGLE CONF VS2SSISZZ007SQ VS2RAISZZ0082Q II II X W.0.#941023023 TO PERFORM NOE. PERFORM -X -UT ANGLE CONFIRMATION, TO SATISFY X S2RF0#7'S EXAMS. UT45 GEOMETRIC x REFLECTOR IS FROM THE WELD ROOT. **25-SAM**
DATE: 04/19/95 REVISION: 1 .CONTAINMENT SPRAY SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 53 8-CS-2227 CREF. DWG. NO. B-79 SHT 1)
- 700640 2P-CSG-311 GUIDE 700645 2P-CSH-303 VAR.SUPPORT,TYP.A,SZ 9,CL-1047,HL-972 8-CS-2227 tPSE&G #8 11-2CS1004l 700930 8-CS-2227-67 FLANGE TO PIPE 700940 8-CS-2227-68 PIPE TO FLANGE
- F-A VT-3 A-E<3/8 F-A VT-3 A-E<3/8 CREF. DI.JG. NO. C-F-1 RT A-E<3/8 PT C-F-1 RT A-E<3/8 PT S2SSISZZ0011Q S2SSISZZ0011Q B-79 SHT 2) VSHSSSPZZ0210Q VSHSSSPZZ0204Q VSHSSSPZZ0210Q VSHSSSPZZ0204Q X --PSI BASELINE PERFORMED PER PS-94-039 I 940824090 I 2EC*3275-1 (MODIFICATION, DUE TO ENGR. REANALYSIS).
X --PSI BASELINE PERFORMED PER PS-94-039 I 940824090 I 2EC-3275-1 (MODIFICATION, DUE TO ENGR. REANALYSIS). x UNDER DCP 2EC-3173, w.o.# 940418179 AND x --CJP# PS-93-092, VALVE 21 & 22CS6 WERE ADDED BACK INTO THE CONTAINMENT SPRAY LINES. THE ISi BOUNDARY IS NOi./ EXTENDED UP TO THIS VALVE
- DURING S2RF0#9 THIS WELD WILL RECEIVE A NEW PSI EXAM. **44-SAM**
x UNDER DCP 2EC-3173, W.0.# 940418179 AND x CJP# PS-93-092, VALVE 21 & 22CS6 WAS ADDED BACK INTO THE CONTAINMENT SPRAY LINES. THE ISi BOUNDARY IS NOW EXTENDED UP TO THIS VALVE, DURING S2RFo#9, THIS WELD WILL RECEIVE A NEW PSI EXAM. **44-SAM** DATE: 04/19/95 REVISION: 1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 54
- CHEMICAL AND VOLUME CONTROL SYSTEM OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERICO, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS
- ASME SEC. XI CATGY EXAM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE 4-CV-2257 CREF. DWG. NO. B-88 SH 1) 707130 4-CV-2257-1 FLANGE TO PIPE C-F-1 C5.21 3-CV-2257 (REF. DWG. NO. B-88 SH 1) 707730 3-CV-2257-7 VALVE 2CV82 TO PIPE C-F-1 C5.21 3-CV-2251 CREF. DWG. NO. B-89 SHT 1) 708300 3-CV-2251-14 PIPE TO ELBOW C-F-1 C5.21 3-CV-2251 CREF. DWG. NO. B-89 SHT 2) 708490 3-CV-2251-20 PIPE TO ELBOW C-F-1 C5.21 2-CV-2244 CREF. DWG. NO. B-90 SH 1) 709220 2-CV-2244-18 PIPE TO VALVE 24CV99 C-F-1 C5.30 PT VS2SSISZZ0075Q UT45 VS2RAISZZ0082Q UT45T II UTOL II ANGLE CONF 11 PT UT45 UT45T UTOL UT60 ANGLE CONF PT UT45 UT45T UT45TAN UTOL PROFILE PT UT45 UT45T UTOL PROFILE PT VS2SSISZZ0075Q VS2RAISZZ0082Q II II II II VS2SSISZZ0075Q VS2RAISZZ0082Q II II VS2RAISZZ0088Q II VS2SSISZZ0075Q VS2RAISZZ0082Q II VS2RAISZZ0088Q VS2RAISZZ0088Q VS2SSISZZ0075Q N 0 0 G* T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X W.0.#941023023 TO PERFORM NOE. X LIMITATION: UT EXAM LIMITED TO 86% CODE X COVERAGE, DUE TO FLANGE AND VALVE X --CONFIGURATION. PERFORMED UT ANGLE X CONFIRMATION TO SATISFY S2RF0#7'S EXAMS. **28-SAM-R** x x W.0.#941023023 TO PERFORM NOE. LIMITATION: EXAM LIMITED TO 80% CODE X --COVERAGE, DUE TO VALVE CONFIGURATION. X UT60 GEOMETRIC REFLECTOR IS FROM THE -X -WELD ROOT. THE INDICATION IS ALSO SEEN X --INTERMITTENTLY FROM 0 TO 180 DEGREES. **30-SAM** X --W.0.#941023023 TO PERFORM NOE. THIS X --EXAM REPLACES SUM# 708650, DUE TO X --PROBLEMS WITH BUILDING PROPER x x SCAFFOLDING. x w.o.#941023023 TO PERFORM NOE. THIS -X -EXAM REPLACES SUM# 708500, DUE TO A X RUBBER BOOT (FIRE PENETRATION SEAL) X --OBSTRUCTING THE WELD. UT45 FOUND A GEOMETRIC REFLECTOR FROM THE WELD ROOT. **30-SAM** X --W.0.#941023023 TO PERFORM NOE.
DATE: 04/19/95 REVISION: 1 .CHEMICAL AND VOLUME CONTROL SYSTEM
SUMMARY
EXAMINATION AREA NUMBER !DENT! Fl CATION ------------------------------ 2-CV-2214 CREF. DYG. NO. B-93 709750 2-CV-2214-13 PIPE TO VALVE 21CV99 2-CV-2219 CREF. DYG. NO. B-101 711710 2-CV-2219-5 TEE TO REDUCER 711860 2-CV-2219-17
- PIPE TO TEE SALEM NUCLEAR POYER STATION UNIT 2 PAGE: 55 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERICO, SECOND OUTAGE C94RF) CLASS 2 CAKPRLE STATUS COMPONENTS N 0 ASME 0 G T SEC. XI R E H CATGY EXAM E 0 E REMARKS ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** ----------
- ----------------------------------------
SH 1) C-F-1 PT VS2SSISZZ0075Q --x Y.0.#941023023 TO PERFORM NOE. THE PT C5.30 UT THICK VS2RAISZZ0088Q x --EXAM REVEALED 2 LINEAR RECORDABLE PT VS2SSISZZ0075Q x INDICATIONS. DURING THE RELEVANCY DETERMINATION PROCESS, THE SURFACE CONDITIONING PROCEEDED A RE-EXAM WITH NO LINEAR INDICATIONS IDENTIFIED. (REF. CNF#94005 & SEAT# 94-411) SH 1) C-F-1 PT VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE. C5.30 C-F-1 PT VS2SSISZZ0075Q x --W.0.#941023023 TO PERFORM NOE. C5.30 2-CV-2217 CREF. DWG. NO. B-102 SH 3) 712720 2-CV-2217-54 PIPE TO VALVE 2CV139 712730 2-CV-2217-55 VALVE 2CV139 TO PIPE
- C-F-1 C5.30 C-F-1 C5.30 PT VS2SSISZZ0075Q ANGLE VS2RAISZZ0082Q x --W.0.#941023023 TO PERFORM NOE. X --W.0.# 941023023 TO PERFORM NDc. PERFORMED UT ANGLE CONFIRMATION, TO SATISFY S2RF0#7'S EXAMS
- DATE: 04/19/95 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 56 REVISION:
1 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3)
- SERVICE WATER SYSTEM SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 3 CAKPRLE STATUS COMPONENTS N 0 ASME 0 G T SEC. XI R E H
SUMMARY
EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTI Fl CATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** ------------------------------
10-2-SW-458 {REF. DWG. NO. SW-2-3L32 723240 2P-SWR-44 F-A VT-3CPSI) S2SSISZZ0011Q x PSI BASELINE PERFORMED PER S-94-102 I RESTRAINT F1.30 VT-3CISI) S2SSISZZ0011Q x 950114003 (REMOVED AND REINSTALLED, TO FACILITATE OTHER WORK). 10-2-SW-535R (REF. DWG. NO. SW-2-3L7) 723680 2P-SWR-49 F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER S-94-102 I RESTRAINT F1.30 950114003 (REMOVED AND REINSTALLED, TO FACILITATE OTHER WORK). 10-2-SW-513 {REF. DWG. NO. SW-2-3L72 723690 2P-SWR-50 F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER S-94-102 I RESTRAINT F1.30 950114003 (REMOVED AND REINSTALLED, TO FACILITATE OTHER WORK) *
- 10-2-SW-527 CREF. DWG. NO. SW-2-3L552 723760 2C-21SWG-6 F-A VT-3 S2SSISZZ0011Q x --W.0.#941023023
& 941119019 TO PERFORM GUIDE F1.30 NOE. AUGMENTED EXAM PERFORMED PER ENGINEERING REQUEST. 24-2-SW-434 {REF. DWG. NO. SW-2-3L102 723940 2P-21SWS-4 F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER S-94-079 I SUPPORT F1.30 941113013 (REMOVED AND REINSTALLED, TO FACILITATE OTHER WORK). 10-2-SW-P-1204 CREF. DWG. NO. SW-2-3L52) 724260 2P-SWR-42 F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER S-94-102 I RESTRAINT F1.30 950114003 (REMOVED AND REINSTALLED, TO FACILITATE OTHER WORK). 10-2-SW-577 {REF. DWG. NO. SW-2-3L602 724350 2C-23SWG-9 F-A VT-3 S2SSISZZ0011Q x --W.0.#941023023 & 941119019 TO PERFORM GUIDE F1.30 NOE. AUGMENTED EXAM PERFORMED PER ENGINEERING REQUEST *
- DATE: D4/19/95 REVISION:
1
- SERVICE WATER SYSTEM
SUMMARY
EXAMINATION AREA NUMBER !DENT! Fl CATION ------------------------------ 10-2-SW-P-1247 CREF. DWG. NO. n5160 2P-SWR-47 RESTRAINT 10-2-SW-P-1240 CREF. DWG. NO. 725190 2P-SWR-48 RESTRAINT SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 58 OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 3 CAKPRLE STATUS COMPONENTS N 0 ASME 0 G T SEC. XI R E H CATGY EXAM E 0 E REMARKS ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** ----------
SW-2-3/54) F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER S-94-102 I F1.30 950114003 (REMOVED AND REINSTALLED, TO FACILITATE OTHER IJORK). SW-2-3/54) F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER S-94-102 I F1.30 950114003 (REMOVED AND REINSTALLED, TO FACILITATE OTHER WORK). PSI BASELINE PERFORMED PER S-94-151 I 941014120 I 2EC-3310 (MODIFIED). NOTE: VT-3 DOCUMENTED AFTER MODIFICATION. 20-2-SW-P-95 CREF. DWG. NO. SW-2-2/5) .726300 A2-SWR-84 F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER S-94-082 I RESTRAINT F1.30 941009005 (REMOVED AND REINSTALLED,, TO FACILITATE OTHER WORK). 20-2-SW-P-1353 CREF. DWG. NO. SW-2-2/28) 726400 2A-SWR-85 F-A VT-3 S2SSISZZ0011Q x --PSI BASELINE PERFORMED PER S-94-079 I RESTRAINT F1.30 941113013 (REMOVED AND REINSTALLED, TO FACILITATE OTHER WORK) .
- DATE: 04/19/95 REVISION:
1
- AUXILIARY FEEDWATER SYSTEM
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISI EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 3 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: 59 4-RD-2-AF-64RW (REF. DWG. NO. AF-2-3/4)
- 727320 23-AFWA-46 ANCHOR 4-2-AF-41 733420 22-AFWG-2 GUIDE 4-2-AF-58 733780 24-AFWG-3 GUIDE 4-2-AF-59 733790 24-AFWG-2 GUIDE 4-2-AF-69 733870 21-AFWG-47 GUIDE 4-2-AF-71 733920 21-AFWS-50 SUPPORT
- F-A F1.30 F-A F1.30 F-A F1.30 F-A F1.30 F-A F1.30 F-A F1.30 VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q VT-3 S2SSISZZ0011Q X --PSI BASELINE PERFORMED PER 2EC-3197 I PS-93-010 I 930802086 (MODIFIED).
X --PSI BASELINE PERFORMED PER 2EC-3191 I PS-93-010 I 930802086 (MODIFIED). x --PSI BASELINE PERFORMED PER 2EC-3197 I PS-93-010 I 930802086 (MODIFIED). x --PSI BASELINE PERFORMED PER 2EC-3197 I PS-93-010 I 930802086 (MODIFIED). X --PSI BASELINE PERFORMED PER 2EC-3197 I PS-93-010 I 930802086 (MODIFIED). X --PSI BASELINE PERFORMED PER 2EC-3197 I PS-93-010 I 930802086 (MODIFIED).
- DATE: 04/19/95 REVISION:
1 PRESSURE TEST
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 1 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** PAGE: CLASS 1 SYSTEMS CREF. DWG. NO. N/A) 950000 SPT-2-RC-001 B-P VT-2 SCSSISZZ0006Q X --W.0.# 941123023 -COMPLETED 12/31/94. ALL CLASS 1 SYSTEMS **PERFORMED IN MODE 3.** #21 AFW PUMP AND PIPING BOUNDED BY 21AF3 ... CREF. DWG. NO. N/A) 950050 SPT-2-AF-001 D-A VT-2 SCSSISZZ0012Q x --W.0.#950503040 -COMPLETED 09/22/94. (AF) AUXILIARY FEED WATER SYSTEM **PERFORMED IN MODE 3.** FEED WATER FOR 21-24 SIG'S CREF. DWG. NO. N/A) 60 .950225 SPT-2-BF-001 C-H VT-2 SCSSISZZ0012Q x --w.o.# 950903014, 950903013, 950903012 & (BF) BOILER FEED SYSTEM 950903015 -COMPLETED 10/13/94.
- BOUNDED BY 21 & 22CA330 & 21 950250 SPT-2-CA-001 (CA) CONTROL AIR & 22CA543 C-H DWG. NO. N/A) VT-2 SCSSISZZ0012Q BOUNDED BY 2CC911 & 2CC313 INSIDE OF CONTAINMENT (REF. DWG. NO. N/A) 950500 SPT-2-CC-005 C-H/D-B VT-2 SCSSISZZ0012Q CCC) COMPONENT COOLING SYSTEM **PERFORMED IN MODE 3.** X --W.0.#950425022
-COMPLETED 10/14/94.
- PERFORMED IN MOOE 3.** X --W.0.#950730003
-COMPLETED 10/14/94.
- PERFORMED IN MODE 3.** BOUNDED BY #2 CONTROL RM A/C UNIT, #2 EXPANSION
.** CREF. DWG. NO. N/A) 950550 SPT-2-CH-001 D-A VT-2 SCSSISZZ0012Q x W.0.#950702015 -COMPLETED 10/05/94. (CH) CHILLED WATER SYSTEM **PERFORMED IN MOOE 1.** DATE: 04/19/95 REVISION: 1 SALEM NUCLEAR POYER STATION UNIT 2 PAGE:
- PRESSURE TEST OUTAGE ISi EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 3 CAKPRLE STATUS COMPONENTS
- *
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASME SEC. XI CATGY EXAM ITEM NO METHOO PROCEDURE BOUNDED BY #2 ECAC & MS RAD MONITORS FOR THE S/G CREF. DYG. NO. N/A) 950600 SPT*2*CH*002 D*A VT-2 SCSSISZZ0012Q (CH) CHILLED YATER SYSTEM BOUNDED BY 2CS900, 2CS901, 2CS902 & 2CS903 CREF. DYG. NO. N/A) 950800 SPT*2*CS*004 C*H VT-2 SCSSISZZ0012Q (CS) CONTAINMENT SPRAY SYSTEM BORIC ACID RECIRC. {100' & 120'}, VCT ROOM ... {REF. DYG. NO. NLA} 950850 SPT*2*CV*001 CCVC) CHEMICAL VOLUME CONTROL SYSTEM eve PIPING DY!j. NO. NLA} 950900 SPT*2*CV*002 CCVC) CHEMICAL VOLUME CONTROL SYSTEM #21 CENTRIFUGAL CHARGING PUMP 951000 SPT-2-CV-004 (CVC) CHEMICAL VOLUME CONTROL SYSTEM #23 CENTRIFUGAL CHARGING PUMP 951100 SPT*2*CV*006 (CVC) VOLUME CONTROL SYSTEM C*H VT-2 SCSSISZZ0012Q C*H VT-2 SCSSISZZ0012Q (REF. DYG. NO. NLA> C*H VT-2 SCSSISZZ0012Q {REF. DYG. NO. NLA} C*H VT-2 SCSSISZZ0012Q N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** x Y.0.#950702016
- COMPLETED 10/10/94.
- PERFORMED IN MODE 1.** x . . Y.0.# 950608020
- COMPLETED 11/14/94.
- PERFORMED IN MODE 5.** x . . Y.0.# 950803008
- COMPLETED 10/14/94.
- PERFORMED IN MODE 3.** x . . Y.0.# 950903011
- COMPLETED 10/14/94.
- PERFORMED IN MODE 3.** x . . Y.0.#950410076
- COMPLETED 10/03/94.
- PERFORMED IN MODE 3.** X *
- Y.0.#950409050
- COMPLETED 09/29/94.
- PERFORMED IN MODE 3.** 61
- DATE: 04/19/95 REVISION:
1 PRESSURE TEST
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE N 0 0 G "T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** BOUNDED BY 21-24 S/G SLOWDOWN LINES TO 21-24GB4 (REF. DWG. NO. N/A) PAGE: 951250 SPT-2-GB-001 C-H VT-2 SCSSISZZ0012Q X --W.0.#950830010 -COMPLETED 10/14/94. (GB) GENERATOR BLO\.JDOWN SYSTEM **PERFORMED IN MODE 3.** #21-24 S/G MAIN STEAM PIPING (REF. DWG. NO. N/A) 62 951300 SPT-2-MS-001 C-H/D-8 VT-2 CMS) MAIN STEAM SYSTEM SCSSISZZ0012Q X --W.0.# 950903014, 950903013, 950903012 & 950903015 -COMPLETED 10/13/94. BOUNDED BY SUCTION FROM #21 HOT LEG THRU #21 ... (REF. DWG. NO. N/A) 951550 SPT-2-RH-001 C-H VT-2 SCSSISZZ0012Q CRH) RESIDUAL HEAT REMOVAL SYSTEM BOUNDED BY 22RH4 THRU 22 RHR PUMP LOOP TO HOT ..* (REF. DWG. NO. N/A) 951600 SPT-2-RH-002 C-H VT-2 SCSSISZZ0012Q CRH) RESIDUAL HEAT REMOVAL SYSTEM BOUNDED BY THE RWST & PUMP SUCTION PIPING DWG. NO. 951800 SPT-2-SJ-001 D-A VT*2 SCSSISZZ0012Q (SJ) SAFETY INJECTION SYSTEM BOUNDED BY 21*24 ACCUMULATOR & 2SJ60 (REF. DWG. NO. N/A) 951850 SPT-2-SJ-002 D-A VT*2 SCSSISZZ0012Q (SJ) SAFETY INJECTION SYSTEM **PERFORMED IN MODE 3.** x --W.0.# 950409051 -COMPLETED 10/19/94.
- PERFORMED IN MODE 4.** x -. W.0.# 950409052
-COMPLETED 10/24/94.
- PERFORMED IN MODE 4.** x --W.O.# 950721014
-COMPLETED 09/30/94.
- PERFORMED IN MODE 5.** --X W.0.# 950805023
-COMPLETED 10/28/94. FOUND A LEAK AT THE #21 ACCUMULATOR SAMPLE LINE CPR# 941108174).
- PERFORMED IN MODE 3.**
- DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE:
- PRESSURE TEST OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS
- *
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASHE SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE BOUNDED BY 21 & 22 SJ44 TO SUCTION OF RHR PUMPS CREF. DWG. NO. N/A) 951900 SPT-2-SJ-003 D-A VT-2 SCSSISZZ0012Q (SJ) SAFETY INJECTION SYSTEM BOUNDED BY 21SS93 & 21SS94 CREF. DWG. NO. N/A) 952450 SPT-2-SS-005 C-H VT-2 SCSSISZZ0012Q (SS) SAMPLING SYSTEM BOUNDED BY 22SS93 & 22SS94 CREF. DWG. NO. N/A) 952500 SPT-2-SS-006 C-H VT-2 SCSSISZZ0012Q (SS) SAMPLING SYSTEM BOUNDED BY 23SS93 & 23SS94 (REF. DWG. NO. N/A) 952550 SPT-2-SS-007 C-H VT-2 SCSSISZZ0012Q (SS) SAMPLING SYSTEM BOUNDED BY 24SS93 &-24SS94 (REF. DWG. NO. N/A) 952600 SPT-2-SS-008 C-H VT-2 SCSSISZZ0012Q (SS) SAMPLING SYSTEM BOUNDED BY 21VC17 & 21VC19 (REF. DWG. NO. N/A) 952650 SPT-2-SS-009 C-H VT-2 SCSSISZZ0012Q (SS) SAMPLING SYSTEM N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.# 950825010 -COMPLETED 11/17/94.
- PERFORMED IN MOOE 5.** X --W.0.#950830014
-COMPLETED 10/14/94.
- PERFORMED IN MODE 3.** X --W.0.#950830013
-COMPLETED 10/14/94.
- PERFORMED IN MODE 3.** X --W.0.#950830012
-COMPLETED 10/14/94.
- PERFORMED IN MODE 3.** X --W.0.#950830011
-COMPLETED 10/14/94.
- PERFORMED IN MODE 3.** X --W.0.#950602020
-COMPLETED 10/20/94.
- PERFORMED IN MODE.5.**
63
- DATE: 04/19/95 REVISION:
1 PRESSURE TEST
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION SALEM NUCLEAR POYER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 2 CAKPRLE STATUS COMPONENTS N 0 ASME 0 G T SEC. XI R E H CATGY EXAM E 0 E REMARKS ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** PAGE: 64 ------------------------------
BOUNDED BY 21VC18 & 21VC20 DWG. NO. 952700 SPT-2-SS-010 C-H VT-2 SCSSISZZ0012Q x --W.0.#950602019 -COMPLETED 10/19/94. (SS) SAMPLING SYSTEM **PERFORMED IN MODE 5.** BOUNDED BY 22VC17 & 22VC19 CREF. DWG. NO. N£A) 952800 SPT-2-SS-012 C-H VT-2 SCSSISZZ0012Q x --W.0.# 950602018 -COMPLETED 11/29/94. (SS) SAMPLING SYSTEM **PERFORMED IN MODE 5.** BOUNDED BY 23SS181 & 23SS182 CREF. DWG. NO. N£A) 952850 SPT-2-SS-013 C-H VT-2 SCSSISZZ0012Q x --W.0.# 950820034 -COMPLETED 12/07/94. (SS) SAMPLING SYSTEM **PERFORMED IN MOOE 5.** BOUNDED BY 21SS181 & 21SS182 CREF. DWG. NO. N£A) 952900 SPT-2-SS-014 C-H VT-2 SCSSISZZ0012Q x --W.0.# 950820033 -COMPLETED 12/07/94. (SS) SAMPLING SYSTEM **PERFORMED IN MODE 5.** BOUNDED BY 23SS184 &-23SS185 DWG. NO. 952950 SPT-2-SS-015 C-H VT-2 SCSSISZZ0012Q x --W.0.# 950820032 -COMPLETED 12/07/94. (SS) SAMPLING SYSTEM **PERFORMED IN MOOE 5.** BOUNDED BY S.W. INTAKE DISCH. HORS BAYS 1 & 2 (REF. DWG. NO. N£A) 953050 SPT-2-SW-001 D-B VT-2 SCSSISZZ0012Q X --W.0.# 950805022 -COMPLETED 09/30/94. (SW) SERVICE WATER SYSTEM **PERFORMED IN MODE 1.**
- DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE: 65
- PRESSURE TEST OUTAGE ISi. EXAMINATION RESULTS CS2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 3 CAKPRLE STATUS COMPONENTS N 0 ASME 0 G T SEC. XI R E H
SUMMARY
EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTI Fl CATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** ------------------------------
*-
BOUNDED BY #23 S.W. PUMP & STRAINER DWG. NO. N/A) 953100 SPT-2-SW-002 D-B VT-2 SCSSISZZ0012Q x --W.0.#950805021 -COMPLETED 10/19/94. (SW) SERVICE WATER SYSTEM **PERFORMED IN MODE 1.** BOUNDED BY #22 S.W. PUMP & STRAINER DWG. NO. N/A) 953150 SPT-2-SW-003 D-B VT-2 SCSSISZZ0012Q x --W.O.# 950805020 -COMPLETED 10/12/94. (SW) SERVICE WATER. SYSTEM **PERFORMED IN MODE 1.** BOUNDED BY #21 s.w. PUMP & STRAINER CREF. DWG. NO. N/A) 95320D SPT-2-SIJ-004 D-B VT-2 SCSSISZZ0012Q x --W.0.#950805019 -COMPLETED 10/04/94.
- (SIJ) SERVICE WATER SYSTEM **PERFORMED IN MODE 1.** BOUNDED BY #26 S.W. PUMP & STRAINER DWG. NO. N/A) 953250 SPT-2-SW-005 D-B VT-2 SCSSISZZ0012Q x --W.0.#950622009
-COMPLETED 09/27/94. (SW) SERVICE YATER SYSTEM **PERFORMED IN MODE 1.** BOUNDED BY #25 S.W * .PUMP & STRAINER CREF. DWG. NO. N/A) 953300 SPT-2-SW-006 D-B VT-2 SCSSISZZ0012Q x --W.0.#950622008 -COMPLETED 10/04/94. (SW) SERVICE WATER SYSTEM **PERFORMED IN MODE 1.** BOUNDED BY #24 S.W. PUMP & STRAINER DWG. NO. N/A) 953350 SPT-2-SW-007 D-B VT-2 SCSSISZZ0012Q x --W.0.# 950622007 -COMPLETED 11/09/94. (SIJ) SERVICE WATER SYSTEM **PERFORMED IN MODE 1.**
- DATE: 04/19/95 REVISION:
1 SALEM NUCLEAR POYER STATION UNIT 2 PAGE:
- OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 3 CAKPRLE STATUS COMPONENTS
- PRESSURE TEST
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASHE SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE BOUNDED BY #21 & 22 S.Y HEADERS CREF. DWG. NO. N/A) 953400 SPT-2-SW-008 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM BOUNDED BY #21 RHR PUMP ROOM COOLER CREF. DWG. NO. N/A) 953500 SPT-2-SW-010 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM BOUNDED BY #21 CCW PUMP ROOM COOLER (REF. DYG. NO. N/A) 953650 SPT-2-SW-013 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE YATER SYSTEM .BOUNDED BY #2 AFW PUMP ROOM COOLER (REF. DWG. NO. N/A) 953700 SPT-2-SY-014 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM BOUNDED BY 2A EMERG,-DIESEL GENERATOR SY VALVES (REF. DWG. NO. N/A) 953750 SPT-2-SW-015 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE YATER SYSTEM BOUNDED BY 28 EMERG. DIESEL GENERATOR SY VALVES (REF. DYG. NO. N/A) 953800 SPT-2-SW-016 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM ** N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.#950625024 -COMPLETED 09/29/94.
- PERFORMED IN MODE 1.** X --W.0.#950527029
-COMPLETED 10/19/94.
- PERFORMED IN MODE 5.** X --W.0.#950804023
-COMPLETED 09/30/94.
- PERFORMED IN MODE 1.** X --Y.0.#950805018
-COMPLETED 09/30/94.
- PERFORMED IN MODE 1.** X --Y.0.# 950627016
-COMPLETED 11/30/94.
- PERFORMED IN MODE 1.** X --W.0.# 950612028
-COMPLETED 11/14/94.
- PERFORMED IN MODE 1.** 66 DATE: 04/19/95 REVISION:
1 .SALEM NUCLEAR POWER STATION UNIT 2 PAGE:
- PRESSURE TEST OUTAGE ISI EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE (94RF) CLASS 3 CAKPRLE STATUS COMPONENTS
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASME SEC. XI CATGY EXAM ITEM NO METHOD PROCEDURE BOUNDED BY 2C EMERG. DIESEL GENERATOR SW VALVES CREF. DWG. NO. N/A) 953850 SPT-2-SW-017 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM BOUNDED BY 21SW23 & 22SW23 CREF. DWG. NO. N/A) 953900 SPT-2-SW-018 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM BOUNDED BY #22 CCW HEAT EXCHANGER CREF. DWG. NO. N/A) 953950 SPT-2-SW-019 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM BOUNDED BY #22 CCW PUMP ROOM COOLER CREF. DWG. NO. N/A) 954000 SPT-2-SW-020 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM BOUNDED BY #22 RHR ROOM COOLER (REF. DWG. NO. N/A) 954050 SPT-2-SW-021 D-B VT-2 SCSSISZZ0012Q (SW) SERVICE WATER SYSTEM BOUNDED BY 2VC7 & 2VC8 CREF. DWG. NO. N/A) N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.# 950505030 -COMPLETED 11/18/94.
- PERFORMED IN MODE 1.** X --W.0.# 950706008
-COMPLETED 12/05/94.
- PERFORMED IN MODE 1.** X --W.0.# 950702017
-COMPLETED 10/11/94.
- PERFORMED IN MODE 1.** X --W.0.# 950816012
-COMPLETED 09/30/94.
- PERFORMED IN MODE 1.** x --w.o.# 950528042
-COMPLETED 10/24/94.
- PERFORMED IN MODE 5.** 67 954750 SPT-2-VC-002 C-H VT-2 SCSSISZZ0012Q x --w.o.# 950605044
-COMPLETED 11/21/94.
- (VC) CONTAINMENT VENTILATION SYSTEM **PERFORMED IN MODE 5.**
DATE: D4/19/95 REVISION: 1 SALEM NUCLEAR POWER STATION UNIT 2 PAGE:
- PRESSURE TEST OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 2 CAKPRLE STATUS COMPONENTS
SUMMARY
EXAMINATION AREA NUMBER IDENTIFICATION ASME SEC. XI CATGY EXAM ITEM NO METHOD BOUNDED BY 2VC9 & 2VC10 CREF. DWG. NO. N/A) 954850 SPT-2-VC-004 CVC) CONTAINMENT VENTILATION SYSTEM C-H VT-2 BOUNDED BY 2VC13 & 2VC14 CREF. DWG. NO. N/A) 954950 SPT-2-VC-006 CVC) CONTAINMENT VENTILATION SYSTEM C-H VT-2 BOUNDED BY 2VC3 & 2VC4 CREF. DWG. NO. N/A) .955000 SPT-2-VC-007 C-H (VC) CONTAINMENT VENTILATION SYSTEM VT-2 PROCEDURE SCSSISZZ0012Q SCSSISZZ0012Q SCSSISZZ0012Q BOUNDED BY 21-24 WGDT, 21 & 22 WGC *.* CREF. DWG. NO. N/A) 955050 SPT-2-WG-001 D-B VT-2 SCSSISZZ0012Q (WG) WASTE GAS SYSTEM BOUNDED BY 2WL98, 99 & 108 CREF. DWG. NO. N/A) 955100 SPT-2-WL-001 C-H VT-2 SCSSISZZ0012Q CWL) WASTE LIQUID SYSTEM BOUNDED BY 2WL12 & 2WL13 CREF. DWG. NO. N/A) 955250 SPT-2-WL-004 C-H VT-2 SCSSISZZ0012C. (WL) WASTE LIQUID SYSTEM
- N 0 0 G T R E H E 0 E REMARKS C M R **CALIBRATION BLOCK** X --W.0.#950605043
-COMPLETED 10/18/94.
- PERFORMED IN MODE 0.** X --W.0.#950602017
-COMPLETED 10/20/94.
- PERFORMED IN MODE 5.** X --W.0.# 950426030
-COMPLETED 12/13/94.
- PERFORMED IN MOOE 5.** X --W.0.# 951103024
-COMPLETED 11/16/94.
- PERFORMED IN MODE 3.** X --W.0.# 950528043
-COMPLETED 11/08/94.
- PERFORMED IN MODE 3.** X --W.0.# 950801010
-COMPLETED 12/23/94.
- PERFORMED IN MOOE 5.** 68 DATE: 04/19/95 REVISION:
1
- PRESSURE TEST
SUMMARY
EXAMINATION AREA NUMBER !DENT! Fl CATION ------------------------------ BOUNDED BY 2WL16 & 2WL17 955300 SPT-2-WL-005 CWL) WASTE LIQUID SYSTEM BOUNDED BY 2WR80 & 2WR81 955350 SPT-2-WR-001 (WR) WASTE RECOVERY SYSTEM CREF. DWG. NO. N/A) 958000 SPT-2-NUREG-0578
- SALEM NUCLEAR POWER STATION UNIT 2 OUTAGE ISi EXAMINATION RESULTS (S2RF0#8, REV. 3) SECOND INTERVAL, FIRST PERIOD, SECOND OUTAGE C94RF) CLASS 2 CAKPRLE STATUS COMPONENTS N 0 ASME 0 G T SEC. XI R E H CATGY EXAM E 0 E REMARKS ITEM NO METHOD PROCEDURE c M R **CALIBRATION.BLOCK**
PAGE: 69 ----------
DWG. NO. N/A) C-H VT-2 SCSSISZZ0012Q x --w.o.# 950803029 -COMPLETED 11/05/94.
- PERFORMED IN MODE 5.** DWG. NO. N/A) C-H VT-2 SCSSISZZ0012Q x --W.0.#950822008
-COMPLETED 10/14/94.
- PERFORMED IN MODE 3.** A-E VT-2 SCSSISZZ0012Q x ALL NUREG EXAMS WERE COMPLETED AS OF 12/07/94 * **PERFORMED IN MODE 1 THRU 5**
- Index of NIS-2 and NR-1 Forms L NIS-2 Forms Comuonent Work Order Brief Description 2C-PRA-146A 950112130 Welded new material to support to increase stiffness 2C-PRA-150A 950112130 Welded new material to support to increase stiffness 2C-PRA-154A 950112130 Welded new material to support to increase stiffness 2C-PRH-209 950112136 Replaced spring can with constant support 2C-PRH-212 950112136 Replaced spring can with constant support 2C-PRH-211 950112136 Replaced spring can with constant support 2C-PRH-211A 950112136 Added new support 2-PRG-26 950112164 Removed shim plates and moved guides to achieve design clearances 2-PRG-51 950112164 Removed shim plates and moved guides to achieve design clearances 2-PRG-27 950112164 Removed shim plates and moved guides to achieve design clearances 2-PRSN-25(A) 950112164 Removed shim plates and moved guides to
- achieve design clearances 2-PRSN-25(B) 950112164 Removed shim plates and moved guides to achieve design clearances 2-PRG-9 950112164 Removed shim plates and moved guides to achieve design clearances 2-PRG-52 950112164 Removed shim plates and moved guides to achieve design clearances 2PR3 Valve 950102113 Replaced valve and bolting 2PR4 Valve 950102117 Replaced valve and bolting 21SJ33 Valve 950120094 2 flange nuts -replaced in kind #23 Charging 940211100 Replaced fluid cylinder in-kind from folio Pump 2PR1 940729107 Replaced cage spacer, cage, stem and plug with new material 2PR2 940729117 Replaced cage spacer, cage, stem and plug with new material 2A-RHR-S-252 940805168 Repair and replacement of existing supports 2A-RHR-G-246 940805168 Repair and replacement of existing supports *
- Component Work Order Brief Descrintion 2A-CVCA-51 940824085 Repair and replacement of existing supports 2A-CVCA-52 940824085 Repair and replacement of existing supports 2A-CVCA-53 940824085 Repair and replacement of existing supports 2P-CSH-303 940824090 Replaced partial or complete existing support 2P-CSG-309 940824090 Replaced partial or complete existing support 2P-CSH-310 940824090 Replaced partial or complete existing support 2P-CSG-311 940824090 Replaced partial or complete existing support 2CV172 940720114 Replaced plug and stem assembly Coupling 940720114 Installed modified piping spool by welding Reducer 940720114 Installed modified piping spool by welding 2CV55 Valve 940424080 Replaced plug and stem assembly 22CV155 Valve 940328170 Replaced valve bolting
- 2RCE1 Blind 930503130 Replaced blind flange for fuel transfer canal Flange w/ new design 2PR73 Tank 940917085 Replace rupture discs Rupture disk Snubber 941019031 Removed snubber and replaced same with 21SGNE like-in-kind Snubber 941019031 Removed snubber and replaced same with 23SGNE like-in-kind 2RCE5 Pump 941013148 Welded cap on pressure tap spools 2RCE7Pump 941013152 Welded cap on pressure tap spools 2RCE9Pump 941013154 Welded cap on pressure tap spools 2RCE3 Pump 941013139 Welded cap on pressure tap spools 22CV157 Valve 970327005 Replaced bonnet assembly 2CVE39 Oil 950221024 Replaced charging pump oil cooler Cooler
- 2SJ156 Check 950103003 Replaced valve disc Valve
- Component Work Order Brief Description 21CA330 930114178 Replaced plug and stem assembly 22CA330 930114178 Replaced plug and stem assembly 21CS6 Valve 940418179 Install containment spray isolation valves 22CS6 Valve 940418179 Install containment spray isolation valves 2CS9A Support 940418179 Install support 2-CS-P-3 940418179 Install support 2-CS-P-4 940418179 Install support 2PR1028 930608174 Replaced bolting Spool to 2PR25 Valve 2PS1 940224133 Replaced valve entered with material of new design and replaced bolting 2PS3 940224123 Replaced valve internals with material of new design and replaced bolting II. NR-1 Forms Code Job# Brief Descri1>tion
- S94-009 Replace valve bonnet in kind (2CV166) PS93-007 Modified pressurizer piping supports (2C-PRLS-403, 2C-PRLS-403, 2C-PRG-2434, 2C-PRG 2435, 2C-PRH 2439, 2C-PRG 2446, 2C-PRS-2438, 2C-PRG-2437, 2C-PRG-2436, 2C-PRSN-401, 2C-PRH-243, 2C-PRS-256 l) PS93-008 Replaced cage, plug and stem assembly with upgraded material (2PR1) PS93-009 Replaced cage, plug and stem assembly with upgraded material (2PR2) PS93-0ll Replaced pipe spool S93-045 Replaced valve and piping in kind from folio (2lMS178)
S93-120 Replace flange bolting S93-126 Performed weld repair to valve leak off line S93-129 Replaced valve bolting S93-215 Valve stem and plug were replaced in kind
- S93-257 The valve was replaced in kind S93-261 The valve -vane taper pins were replaced in kind and seal welded.
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date March 6 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of_..__ __________
_ Address 2. Plant Salem Generating Station Unit# _.=.2 ____________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 WO #950112130 CJP #PS95-002 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_,,,P"""S"'"E""&:::.;G'"'--------- Type Code Symbol Stamp Name Authorization No. _ ___,;.___,N'""l""A...__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ Address 4. Identification of System Reactor Coolant -Pressurizer Pipe Support Nuclear Class I S-C-MBOO-MDS-043
- 5. (a) (b) Applicable Construction Code Rev. 0 19_ Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components
- 7. 8. Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No . Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Pipe Support PSE&G NIA NIA S2-2C-PRA-1995 Replacement No 146A Pipe Support PSE&G NIA NIA S2-2C-PRA-1995 No 150A Pipe Support PSE&G NIA NIA S2-2C-PRA-1995 Replacement No 154A --Descrip_tion of Work Welded new material to support to increase stiffness.
DCP #2EC-3347 Pkg. 1 Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure __ psi Test Temp. __ oF VT-3 Pre-Service Exam NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New.York, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules reparr or replacement Type Code Symbol Stamp __
___ _ *---------------------------- Certificate of Authorization No. _ Expiration Date ____________ _ Signed de:£i .. 4'Lu Owner or Owncr's'Designee, TiUt: Date -? -2 , 19 t'5= CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual ins. Co. of MA have inspected the components described in this Owner's Report during the period / -../ 1//{S to 3 -f-tr<, and state that to the best of my knowledge and belief: the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and cortective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. _____ _ / lllSpectOr's National Board, State, Province, and Endorsements
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date March I 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet_l_of_'------------
Address 2. Plant Salem Generating Station Name ___________ _ PO Box 236. Hancocks Bridge. NJ 08038 WO #950112136 CJP PS-95-003 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp Authorization No. __ ___._N"""/A,_._ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date _____ _ Address 4. Identification of System . Reactor Coolant <Pressurizer Hangers) Nuclear Class II S-C-MBOO-MDS-0043
- 5. (a) Applicable Construction Code Rev. 0 19_ Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Constant PSE&G NIA NIA ,.-2c..m-209 1995 Replacement No Support rtr11 Constant PSE&G NIA NIA 2C-PRH-212 1995 Replacement No Support Constant PSE&G NIA NIA 2C-PRH-211 1995 Replacement No Support Variable PSE&G NIA NIA 2C-PRH-1995 New No Support 21 lA 7. Description of Work Replaced spring can supports with constant supports.
added one new variable support. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other Pressure_ psi Test Temp. __ OF VT-3 Pre-service Exam NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) infonnation in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules repair or replacement Certificate of Authorization No. --'N""'/_,_A..__
__________ Expiration Date Signed
- Owner or Owner's Des;gnee;i'i{ie-Date s -'L... ,19 "lr CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Cp, of MA have inspected the components described in this Owner's Report during the period to {-6-tfJ , and state that to the best of my knowledge and belie( the Owner has performed examinations and taken corrective measures described in. this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and cortl!ctive measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engr. Assn. Commissions Nf}/_) --7--t"-" National Board, State, Province, and Endorsements Date __ L..-J--(,=-* __ 19 q S
- * * .,. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I . Owner Public Service Electric & Gas Co. Date March3. 1995 Name PO Box 236, Hancocks Bridge. NJ 08038 Sheet _I_ of__,2=------------
Address 2. Plant Salem Generating Station Name Unit# __,2...__ ___________ _ PO Box 236. Hancocks Bridge. NJ 08038 WO #950112164 CJP #PS-95-004 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_.P-"S=E=&=G.,__ ______ _ Type Code Symbol Stamp """'N""'IA_,,_ _____ _ Name Authorization No. PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ N,........IA_.__ _____ _ Address 4. Identification of System Reactor Coolant -Pressurizer Pipe Support Nuclear Class II S-C-MBOO-MDS-043
- 5. (a) (b) Applicable Construction Code Rev. 0 19_ Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement Pipe Support PSE&G NIA NIA 2-PRG-26 1995 Repaired (Guide) Pipe Support PSE&G NIA NIA 2-PRG-51 1995 Repaired (Guide) Pipe Support PSE&G NIA NIA 2-PRG-27 1995 Repaired (Guide) --Snubber PSE&G NIA NIA 2-PRSN-1985 Repaired 25(A) Snubber PSE&G NIA NIA 2-PRSN-1985 Repaired 25(B) ASME Code Stamped (Yes or No) No No No No No 7. Description of Work Removed shim plates and moved guides to achieve design clearances.
DCP #2EC-3348 Pk . l 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure_ psi Test Temp. __ "F VT-3 Pre-Service Exam NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x I I in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. I 0017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repaired conforms to the rules of the ASME Code, Section XI repair or replacement Certificate of Authorization No. _ _,N'""""/A_,_
__________ Expiration Date __,N'""""/A_,_ __________ _ Signed 4yz Date .5' 2 CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Cu. of MA have inspected the components described in this Owner's Report during the period to } *-Y-'f5 . and state that to the best of my knowledge and belief; the O.wner has performed examinations and taken corrective measures described this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. --,,_ ___ _____ _ Signature National Board, State, Province, and Endorsements Date J-y
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date March 3 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _2_ of__,2,.__
__________ _ Address 2. Plant Salem Generating Station Name Unit# PO Box 236. Hancocks Bridge. NJ 08038 WO #950112164 CJP #PS-95-004 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Type Code Symbol Stamp ""'N"""IA......_ _____ _ Name Authorization No. __ ___,N....:.:/"'-A..__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System Reactor Coolant -Pressurizer Pipe Support S-C-1.ffiOO-MDS-043
- 5. (a) (b) Applicable Construction Code Rev. 0 19_ Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement Pipe Support PSE&G NIA NIA 2-PRG-9 1995 Repaired (Guide) Pipe Suppa t (Guide) PSE&G N/A N/A 2-PRG-52 1995 Repaired --ASME Code Stamped (Yes or No) No No 7. Description of Work Removed shim plates and moved guides to achieve design clearances.
DCP #2EC-3348 Pk . I 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure_ psi Test Temp. __ of VT-3 Pre-Service Exam NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is.numbered and the number of sheets is recorded at the top o: ..:Lis form. (12182) This Fonn (EOOOJO)*may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017 '
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repaired conforms to the rules of the ASME Code, Section XI repair or replacement Certificate of Authorization No. _
Expiration Date _N'""""'/A-"------------ Signed 7 Owner or Owner's Desigflee;Tie Date 3 -7 '19 CERTIFCATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arjs.wright Mutual Ins. of MA have inspected the components described in this Owner's Report during the period J -/ t/-9S to f *-Y2.L _ and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. Date Jf i9Yr
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date February 13. 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _l _of_,__ __________
_ Address 2. Plant Salem Generating Station Name Unit# -=2 ____________ _ PO Box 236. Hancocks Bridge. NJ 08038 WO #950102113 CJP S95-006 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp ""'N,,,.IA_,__ _____ _ Authorization No. -----=N""l..._A,__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ -.:..N:.:.:IA'-'"-------- Address 4. Identification of System Reactor Coolant 2PR3 Valve -Nuclear Class I WE-Spec 5. (a) Applicable Construction Code 676279 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2PR3 Valve Crosby RV-8010A NIA NIA 1971 Replacement N AMP Studs (12) Allied Nut& HT NIA NIA NIA Replacement N Bolt Co. #8861963 Nuts (24) Allied Nut & HT#02293A NIA NIA NIA Replacement N Bolt Co. -* 7. Description of Work Replaced valve and bolting. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressw-e D Other D Pressw-e NOP psi Test Temp. NOT OF System Leakage Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. * * (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
- FORM NIS-2 (Back) *
- 9. Remarks WO 950102113 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules repaU" or replacement Certificate of Authorization No. _ _..N""/_,_A...._
__________ Expiration Date Signed L L/.Luk. /JcVk-<.:;J A. -"' ;;> or Owner's Oesignee, Titre Date 2 -fl( CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period / .-/ /-f 5 to .2 'I and state that to the best of my knowledge and belief: the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall
- be liable in any manner for any personal injuiy or property danrage or a loss of any_ kind arising from or connected with this inspection.
Factoiy Mutual Engr. Assn. Date __ ...L..}_--'-)_f __ 19 9 S-
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date Februrux 13. 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _l _of__,'------------
Address 2. Plant Salem Generating Station Unit# -"""2 ____________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 WO #950102117 CJP S95-007 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp .._.N"""IA...__ _____ _ Authorization No. ---"'-N ...... IA......__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System Reactor Coolant 2PR4 Valve -Nuclear Class I WE-Spec 5. (a) Applicable Construction Code 676279 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components
- 7. 8. Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2PR4 Valve Crosby RV-2-8010-NIA NIA 1971 Replacement N PNJ Studs (12) Allied Nut & HT NIA NIA NIA Replacement N Bolt Co. #8861963 Nuts (24) Allied Nut& HT#02293A NIA NIA NIA Replacement N J?.olt Co. Description of Work Replaced valve and bolting. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other 0 Pressure NOP psi Test Temp. NOT OF System Leakage Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. * (12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, N. Y. 10017
- FORM NIS-2 (Back) *
- 9. Remarks W095102117 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Re.placement conforms to the rules repair or replacement Type Code Symbol Stamp ___
__________________________ _ Certificate of Authorization No. _ ... A""------------ Expiration Date ... A""------------ Signed > 1/&f:e;s Date 2-tY , 19 ?s= CERTIFCATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period { / / ... q S to 2 -Ir--Cf?' and state that to the best of my knowledge and belief: the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. _(}="""--'-" /__,__{__,,, _Commissions _N-=;J---"-J---'7 _]"------- Signature National Board, State, Province, and Endorsements ...--Date 2 --I j 19 '1 ..\ ----------------
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date Februruy 13. 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of_,__ __________
_ Address 2. Plant Salem Generating Station Name Unit# __.2,.__ ____________ _ PO Box 236. Hancocks Bridge. NJ 08038 WIO 950120094. CJP S95-012 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed _____ _ Type Code Symbol Stamp ""'N""'IA-=-------- Name Authorization No. __ ---.N=/,_,A.__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ No..:.:.:./A....._ _____ _ Address 4. Identification of System Safety Injection -Nuclear Class II
- Valve 21SJ3 3-5. (a) (b) Applicable Construction Code ANSI B3 l. 7 19 .Q2.__ Edition, -1.21.Q_ Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Nuts Allied Nut& NIA NIA NIA NIA Replacement N Bolt .. 7. Description of Work The 2S49E strainer spool -2 flange nuts replaced in kind. 8. Tests Conducted:
Hydrostatic 0 Pneumatic D Nominal Operating Pressure D Other 0 Pressure NIA psi Test Temp. __ OF System Inservice Test@ NOP/NOT NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) infonnation in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recQrded at the top of this form. -(12182) Th.is Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th Sl, New York, N.Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Re.placement conforms to the rules repair or replacement Certificate of Authorization No. _ _,N'"""'"/A......._
__________ Expiration Date Signed /)_A * -* ' Owner or Owner's Date 2 -r I( , 19 'Pf--CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins . .Co. of MA have inspected the components described in this Owners Report during the period * /-J '-/ q Sto J. ""I [-,.£j J , and state that to the best of my knowledge and beliel'; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. __ Commissions_N--'-u.......:;.?-=11"--------IDSPCctOis Signature National Board, State, Province, and Endorsements Date 2-lr 19
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Name* End of Buttonwood Rd.,Hancocks Bridge,NJ Address Salem Nuclear Generating Station Name End of Buttonwood Rd.,Hancocks Bridge,NJ Address 3. Work Perfonned by_P_S_E_&_G
____________ _ Name End of Buttonwood Rd.,Hancocks Bridge.NJ Address Sheet _ __. __ of ___ _.__ ________ _ _______________ _ Work Order #94021JJ00 c.rp S94-02l Repair Organization P.O. No., Job No., etc. Type Code Symbol Stamp __ ..,.N..,.l'""A,._ ______ _ Authorization No. _____ Expiration Date _____ __.'+-',._ ______ _ 4. __ _______________________ _ Draft Pump 5. (a) Applicable Construction Code & Val Ve _____ Addenda, __ ____ Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or Nol #23 Charging Union Pump 107982 N/A N/A 1989 Replacement No Pump Company c -* 7. Description of Work Replace 'fluid cylinder in-kind from folio. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other [3 Pressure_N_O_P ___ psi Test Temp. NOT ° F System Inservice Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1 I size is 8Y:z in. x 11 in., (2) tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form . (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE W "f h h d . h . Replacement f h I f h e cert1 y t at t e statements ma e int e report are correct and this con arms tot e rues o t e ASME Code, Section XI. repair or replacement N/A N/A Certificate of Authorization No. _______________
Expiration Date----------------.> wner or Owner's Designee;TitJ Date 3 . J 9
- 19 ? :Y CERTIFICATE OF INSERVICE INSPECTION I, the holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State P . f Jersey d 1 db Arkwright Mutual Ins. Co. f r-iKr rov1nce o an emp aye y -o ------------------------,----=--::,--, ____ have inspected the components described J -29
- 1 i/ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accorpance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Factory Mutual Engr. Assn. Y / " AklJ 7" 7 .. _,..**
_____ lns;;actor's National Board, State, Province, and Endorsements
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASIHE Code Section XI 1. Owner Public Service Electric & Gas Co. Date Januaiy 27. 1995 Name PO Box 236. Hancocks Bridge NJ 08038 Sheet_l_of_.__
__________ _ Address 2. Plant Salem Generating Station Unit# __,2....._ ____________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 PS 94-031 WO 940729107 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Type Code Symbol Stamp Authorization No. __ Name PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ __._N"""/._.A,__ _____ _ Address 4. Identification of System Westinghouse Specification
- 5. (a) Applicable Construction Code E676270 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 _82_ 6. Identification of Components Repaired or Replaced and Replacement Components
- 7. 8. Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Boa!'d Identification Built Replaced, or Code No.
---r--------------... -r--(Yes or No) 2PR1 Copes Vulcan 6910-95001-NIA NIA 1969 Replacement No 164-4 -* Description of Work Replaced cage §Pacer. cage. stem and plug with new material. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other 0 Pressure NOP psi Test Temp. NOT OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( 1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. I 0017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules reparr or replacement Certificate of Authorization No.
Expiration Date Signed Date / -] CJ
- 19 /"..;-CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of MA have inspected the components described in this =--'-----'"--"---
and state that to the best of my knowledge and belief'; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. __ _Commissions _M_0_J_J_5 ________ _ /Inspector's Signature National Board, State, Province, and Endorsements Date } -/ I 9 9 < ----------
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date January 27. 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet_l_
Address 2. Plant Salem Generating Station Unit# Name PO Box 236. Hancocks Bridge. NJ 08038 PS 94-032 WO 940729117 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_..P--=S=E=&=G'"'--------- Type Code Symbol Stamp """'N"""'"IA-=-------- Name Authorization No. __ __.N"""l_,_A..__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ _.._N,,.IA,_.__ ______ _ Address 4. Identification of System __..R=e=a=ct=o""-r-"C=oo=lan==-t Westinghouse Specification
- 5. (a) Applicable Construction Code E676270 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2PR2 Copes Vulcan 6910-95001-NIA NIA 1969 Replacement No 164-3 _, 7. Description of Work Replaced cage spacer. cage. stem and plug with new material.
8.. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure NOP psi Test Temp. NOT OF NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, N. Y. 10017
- 9.
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules reparr or replacement Type Code Symbol Stamp ___
__________________________ _ Certificate of Authorization No. NI A Expiration Date __.N'""'/'"'"A_,__ _________ _ Signed Y ,.,d d.rr Date ---'-/_-_.r_o _____ , 19 7-S'--Owner or Owner's Designee, Title CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ofNew Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period f: J6,-1t( to } -J-fj' , and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. _.......,.Q* f'-'-, } _____ _ T Inspector's Signature National Board, State, Province, and Endorsements Date ____ 2_-_f __ 19 7 r'
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 Address 3. Work Performed Name PO Box 236. Hancocks Bridge. NJ 08038 Address Date December 14 1994 Sheet _I_ of_,__ __________
_ Unit# CJP PS-94-037 WO 940805168 Repair Organization P.O. No., Job No., etc. Type Code Symbol Stamp _____ _ Authorization No. Expiration Date
- 4. Identification of System -""RHR=....
.......... N....,u=c=le=a'°"-r-=C=la=s=s..,.,II'-----------------------
- 5. (a) (b) Applicable Construction Code See Remarks 19_ Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 _M_ 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No . Replacement Stamped (Yes or No) Pipe Support PSE&G NIA NIA NIA 1994 Repair No (A) Pipe Support PSE&G NIA NIA NIA 1994 Replacement No (B) " .. I ' 7. Description of Work Repair and replacement of existing supports IAW DCP 2EC-3275 Pkg. 01 8. Tests Conducted:
Hydrostatic 0 Pneumatic CJ Nominal Operating Pressure 0 Other 0 Pressure NIA psi Test Temp. NIA OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( 1) size is 8 l /2 in. x 11 in., (2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and
- the number of shee,ts is recorded at the top of this form. ( 12182) ll1is Fonn (EOOOJO) may be obtain<!d from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
- *
- FORM NIS-2 (Back) 9. Remarks -=5._.CA_,_),_S,,,p""'e=c"-:
_,6...,9'--=6-'-44....,:i""'- =O _________ _ 6CA) 2A-RHR-S-252 6(B) 2A-RHR-G-246 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE Repair/ We certify that the statements made in the report are correct and this Replacement of the ASivlE Code, Section XI repair or replacement conforms to the rules Certificate of Authorization No. NIA Expiration Date __,N'""/""A_,__ __________ _ Date I -z.. -/ '19 '7-'-;;:.- CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the p.;riod rJ -cf-<?-7* to / 1;U /, and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrccti'.'C measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. r----...... _.,,./2 ___ _____ Commissions e+/- ho S d .:' Cf..) r*J ;(.,l..J-Y J' / Inspector's Signature National Board, State, Province, and Endorsements Date I i... -/j 19 LL /
- * * --FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 22 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet_l_
Address 2. Plant Salem Generating Station Name Unit# PO Box 236. Hancocks Bridge, NJ 08038 WO 940824085 CJP PS94-038 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by .... P-"S=E=&"'-G=-------- Type Code Symbol Stamp Name Authorization No. __ _....N""/.._A....._ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System _2_A_-_c_v_c_A_-_5_3 __ _ 5. (a) (b) Applicable Construction Code See Remarks 19_ Edition, NI A Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Pipe Support PSE&G NIA NIA NIA .1994 Replace N (A) Pipe Support PSE&G NIA NIA NIA 1994 Replace/ N (B) Repair Pipe Support PSE&G NIA NIA NIA 1994 Replace N (C) --7. Description of Work Repaired and replacement of existing supports IA W DCP 2EC-3275 Pkg. 0 I 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure NIA psi Test Temp. NIA OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( 1) size is 8 1 /2 in. x 11 *in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
- 9. *
- FORM NIS-2 (Back)-Remarks 5.(1) Spec 69-6445 Rev. 9 -Spec S-C-MBOO-MDS-043, Rev. 0 Applicable Manufacturer's Data Reports to be _attached 6.(A) 2A-CVCA-51 CB) 2C-CVCA-52 (C) 2C-CVCA-53 CERTIFICATE OF COMPLIANCE Repair/ We certify that the statements made in the report are COITect and this Revlacement of the ASME Code, Section XI reparr or replacement conforms to the rules Certificate of Authorization No. _
__________ Expiration Date _N'-"-'-/A..._ _________ _ Signed ,.,.. Owner or Owner's Design;,Tul;r=-Date I :L -:i...3 '19 .y y: CERTIFCATE OF INSERVICE INSPECTION undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period to / l -Z. 1-frYand state that to the best of my knowledge and belief: the I Owner has perfom1ed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. &zo 5--Z LJ / 'Ss r s V.:J-y.,j> / Inspector's Signature Date I z-L? 19 / National Board, State, Province, and Endorsements
- *
- FORM NIS-2 OWNER'S REPORT FOR REP AIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 16 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of__,.__ _________
_ Address 2. Plant Salem Generating Station Name Unit# --=2 ____________ _ PO Box 236. Hancocks Bridge. NJ 08038 WO 940824090 CJP PS 94-039 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_,.P_,.S=E=&=G'""--------- Type Code Symbol Stamp Name Authorization No. __ ___._N"""IA,_._ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System CCS) Cont. Spray Nuclear Class II 5. (a) (b) Applicable Construction Code See Remarks 19_Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, AS:ME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Support 2P-PSE&G NIA NIA NIA 1994 Replacement N CSH-303 Support 2P-PSE&G. NIA NIA NIA 1994 Replacement N CSG-309 Support 2P-PSE&G NIA NIA NIA 1994 Replacement N CSH-310 Support 2P-PSE&G NIA NIA NIA 1994 Replacement N CSG-311 7. Description of Work Replaced partial or complete existing supports IAW 2EC-3275.
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other 0 Pressure NIA psi Test Temp. NIA OF NOTE: Supplemental sheets in form of!ists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11
- in;, (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) TI1is Fonn (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New Yorlc, N.Y. 10017
- 9. *
- FORM NIS-2 (Backr Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI repaU" or replacement conforms to the rules Certificate of Authorization No. __
_________ _ Expiration Date _N=.=/A'-'------------ Signed 7 Owner or Owner's Designee;fu1e Date ---L-/_2-._-_2.---'2-.=---, 19 CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period to .J 2--2 *7 ,{.,...y.tnd state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this .Owner's Rep.ort in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. & /lJ/ O'J .t'..s tJ..7"""7 ..3 / Inspector's Signature National Board, State, Province, and Endorsements Date _ _,,_/_2-_, 7/'--J..::;__7"---- 19 7 /('
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date March 7 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _l _of_.__ __________
_ Address 2. Plant Salem Generating Station Name Unit# ---:::2.__ ____________ _ PO Box 236. Hancocks Bridge. NJ 08038 WO 940720114 CJP PS94-048 DCP 2EC-3225 Pkg. I Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by"""P_,.S=E=&=G,.__ ______ _ Type Code Symbol Stamp .._N"""'I A-=-------- Name Authorization No. ----"N""l_,_A...__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ __._N'""IA....._ ______ _ Address 4. Identification of System Chemical Volume Control 2CV172 -Valve Nuclear Class II WE-Spec 5. (a) Applicable Construction Code E-676270 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Component Manufacturer Serial No. Board Identification Built No. Stem Masoneilan NIA NIA . HT #144290-NIA Assembly 10 Plug Masoneilan NIA NIA HT NIA #IGI358-2 --7. Description of Work Replaced plug and stem assembly.
- 8. Tests Conducted:
Hydrostatic Pneumatic D Nominal Operating Pressure D Other Pressure_llL psi Test Temp. _]Q_ oF Repaired, ASME Replaced, or Code Replacement Stamped (Yes or No) Replacement N Replacement N NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) infonnation in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. * (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- *
- FORM NIS-2 (Back) 9. Remarks WO #940720114 DCP #2EC-3225 Pkg. I Applicable Manufacturer's Data to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the AS:ME Code, Section XI Replacement conforms to the rules repatr or replacement Certificate of Authorization No. _
_________ Expiration Date _..N'""""'"/A..__ _________ _ Signed ..,. Owner or Owner's igllCC;i de Date f'-$ '19 ::rs--CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins . .Q6. of MA have inspected the components described in this Owner's Report during the period to J-9-1{ . and state that to the best of my knowledge and belief; the Owner has performed and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, ::,ection XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. Date ___ J_--_1 __ 19 fj__
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date _
Name PO Box 236, Hancocks Bridge, NJ 08038 Sheet*_!_ of_,__ __________ _ Address 2. Plant Salem Generating Station Unit# ___,2,,__ ____________ _ Name PO Box 236, Hancocks Bridge, NJ 08038 WO 940720114 CJP PS94-049 DCP 2EC-3225 Pkg. I Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by,....P-"S=E=&=G=---------- Type Code Symbol Stamp ._N""'IA....._ _____ _ Name Authorization No. __ ___.N-"l.._A..__ _____ _ PO Box 236. Hancocks Bridge, NJ 08038 Expiration Date ___ _._N""'I A'-'-------- Address 4. Identification of System Chemical Volume Control Nuclear Class II 5. (a) (b) Applicable Construction Code ASME 831.7 l 9_Q2__ Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Coupling Empire Valve NIA NIA HT#CUC NIA Replacement N & Fitting Co. Reducer DuBose Nat'!. NIA NIA HT#EHJ NIA Replacement N Energy -* 7. Description of Work Installed modified piping spool by welding. 8. Tests Conducted: Hydrostatic r;i Pneumatic D Nominal Operating Pressure D Other D Pressure__llL psi Test Temp. _]J)__ °F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 112 in. l 1 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this fo1m. ( 12182) This Forni (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- *
- FORM NIS-2 (Back) 9. Remarks WO #940720114 2EC-3225 Pkg. 1 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the stat((ments made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules repair or replacement Type Code Symbol Stamp __ -'-'N'"""/A_,__
_____________
Certificate of Authorization No. __ Expiration Date Signed L4L.Lu.&,,,* !l A" "' *"' Owner or Owner's DlSignee, Title ,-Date J'-,19 ??' CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel lnspectors and the State or Province of New Jersey and employed by Arkwright Mutual lns,..eo. of MA have inspected the components described in this Owner's Report during the period /tJ -C -9 i/ to ? .-f-9 ).,,.. , and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. _:::;C.L--=-----_** _Commissions __.:_A/__:5:.....:::7-'-1-=-.3 ______ _ . National Board, State, Province, and Endorsements Date ___ 19 /
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 Address 3. Work Performed by .... P-=S=E=&=G"'---------
Name PO Box 236. Hancocks Bridge. NJ 08038 Address Date December 27 I 994 Unit# q 1/0l/ W0-94042080-CJP S94-086 Organization P.O. No., Job No., etc. Type Code Symbol Stamp ..... N....,IA....__ _____ _ Authorization No. __ __,_N...,_IA ........ _____ _ Expiration Date ____ No..:..:..o/A-"---------
- 4. Identification of System Chemical Volume Control -2CV55 -Valve -Nuclear Class II 5. (a) (b) Applicable Construction Code AS:ME DP&V I9...@__Edition, WnO Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, AS:rvffi Component Manufacturer Serial No. Board Identification Built or Code No. Replacement Stamped (Yes or No) 2CV55 Valve Copes Vulcan 7410 95269-NIA NIA I976 Replacement N I-2 ' : --7. Description of Work Replaced plug and steam assembly.
- 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure Other ll Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 Il2 in. x I I in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (I2182) 11tis Form (E00030) may be obtained from the Order DepL, ASME, 345 E. 47th SL, New York, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the rep011 are c01Tect and this Replacement of the ASME Code, Section XI reparr or replacement conforms to the rules Certificate of Authorization No. _ _,N'"'/_,_A...._
__________ Expiration Date ___.N.....,./A_.__ _________ _ . Date ___ /_-_3 __ , 19 9c=: -Owner or Owner's CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ofNew Jersev and emplored ';Y Arkwright Mutual of MA have inspected the components described in this Owner's Report during the period C:,jr,tf 7' to /-.Y-7J , and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the fospector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. Commissions 6 A/./ d's/ s µ7 </3' ( ' Inspector's Signature National Board, State, Province, and Endorsements /-3 Date_.;.,__ ____ 19 7 v
- *
- 1. Owner PSE&G FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI June 22, 1994 Name PO Box 236, Hancocks Bridge,NJ 1 1 Sheet ____ of ___________
_ Address 2 Pl Salem Generating Station
- ant ____________________
_ #2 Unit _________________ _ Name PO Box 236, Hancocks Bridge,NJ WO 940328170 CJP S94-090 Address Repair Organization P.O. No., etc. PSE&G 3. Work Performed by _______________ _ Type Code Symbol Name Authorization No. N/A Expiration Date _____________ _ PO Box 236, Hancocks Bridge,NJ Address Chemical Volume Control 22CV155 Valve 4. Identification of System _______ ...... E-Spec Rev. 2 Huclearass xx E-676281 N/A N/A N/A 5. (a) Applicable Construction Code 19 __ Edition, 86 Addenda, _______ Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 __ _ 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or Nol studs ITT N/A N/A N/A N/A Rep lac N ---__ .._ bL' innc ... J. --**T-Nuts Allied N/A N/A N/A N/A Replace N -----.L.. j\IU l:.llltlOJ. 1:'. *---*-Replaced valve bolting. 7. Description of Work _____________________________________ _ 8. Tests Conducted: Hydrostatic D Pneu"NBI(J Nominal Operating 0 Other [:i Pressure _____ psi Test Temp. ° F /2..S-177 System Inservice Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1 I size is BY.. in. x 11 in., (2) tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form . (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repl a cemeDtforms to the rules of the ASME Code, Section XI. repair or replacement Certificate of Authorization No. __ _.N'°",,_/_..A...._
_________ Expiration Date __ Signed Lb.a£. L <y--f' 7 Owner or Owner's Designee, Tltle Date 6 -::1-3 , 19 9fr:
- CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwrj ght Mutual Ins Co of have inspected the components described in this Owner's Report during the period ___ ,_-_'-....::....:.(_-__,f..._.J.,__
__ to J / 7" and state that +-r I r-, to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. commissions /,.,. z.ea l..T/f.lc:rLJ-.:J I Inspector's Signature Natlonal Board, State, Province, and Endorsements Date. __ G_-__ ____ 19 'F '("
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 21 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Unit# __,2,.__ ____________
_ Name PO Box 236. Hancocks Bridge. NJ 08038 WO 930503130 2EC-3200 CJP S94-091 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Type Code Symbol Stamp A__,__ _____ _ Name Authorization No. PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date _____ _ Address 4. Identification of System Reactor Coolant 2RCE 1 -Fuel Transfer Blind Flange Nuclear Class I WE-Spec 5. (a) Applicable Consb.uction Code 677020 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2RCE1 Blind Westinghouse Pt. #25-NIA NIA 1972 Replacement N Flange 4C34H01 --7. Description of Work Replaced blind flange for fuel transfer cane! wlnew design. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other ,B Pressure NIA psi Test Temp. NIA OF Type "B" leak rate test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( 1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet-is numbered and the number of sheets is recorded at the top of this (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- FORMNIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are coJTect and this Replacement of the ASME Code, Section XI repair or replacement conforms to the rules Certificate of Authorization No. __
Expiration Date ___________ _ Owner or Owner's Date J 2--L...-l__ ,19 9 y CERTIFCATE OF INSERVICE INSPECTION
- L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period / O -2. a..'?-/ to i l. -.2. J -H. and state that to the best of my knowledge and the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engr. Assn. o L,L;J J {:. ,,(_)I (] s* i J p/ J/3 ( 1;-__:;'-"> ______________ Commissions lnspector's Signature National Board, State, Province, and Endorsements Date _/_L_-__ 2-_J __ l 9 9 L
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 13 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name Unit# --"2=--------------
PO Box 236. Hancocks Bridge. NJ 08038 WO 940917085 CJP S94-l l 7 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_..P""'S=E&=G"'--------- Type Code Symbol Stamp ..... N ..... IA....._ _____ _ Name Authorization No. __ _._N .... IA,_._ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ N=/A_,_ _____ _ Address 4. Identification of System Reactor Coolant 2PR73 Tank Rupture Disk Nuclear Class II 5. (a) (b) Applicable Construction Code ASME III Class C 19 68 Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, AS:ME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Rupture Westinghouse NIA NIA NIA NIA Replacement N Disk --7. Description of
- 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure Other '1 Pressure NOP psi Test Temp. _NOT OF Inspection Test at Mode 3 ; NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this fonn. (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI rcparr or replacement Certificate of Authorization No. _ _,N""/"'-A-=------------
Expiration Date _N"""""'/A......_ _________ _ Signed .. 4r Date /-r* , 19 ?J= CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period 9-W " <J { to / -I 0 9 ( and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. _ _,Q,,_,
- t)';J 3 7 3 / Inspector's Signature National Board, State, Province, and Endorsements
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date December 22 I 994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _1 _of_.__ _________
_ Address 2. Plant Salem Generating Station Unit# _ _,2.__ ___________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 W/O 941019031. PR 941031 I67. CJP S94-I44 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Type Code Symbol Stamp ,.,,NCC!/ A_.__ _____ _ Name Authorization No. __ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ ___....N.!!./.!...JA.__ _____ _ Address 4. Identification of System __ 'J._/_S--=:(;._. _;V_1Z ___ s--'s'--_I __ _ 5. (a) (b) Applicable Construction Code ANSI B3 l.7 19_Q2_ Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No . Replacement Stamped (Yes or No) Snubber Rexnord 90057-27 NIA NIA I975 Replacement No i --' 7. Description of Work Removed snubber and replaced same with like-in-kind.
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure D Other D Pressure NIA psi Test Temp. NIA OF NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (I) size is 8 1/2 in. x I I in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) 111is Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St, New Yorlc, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Remarks ____________________________________________________________________ Applicable Manufacturer's Data Repons to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI repa1r or replacement conforms to the rules Type Code Symbol Stamp ___ N-=/A..._
___________________________ _ Certificate of Authorization No. _ _,N""/"'"A..__ __________ Expiration Date __,N'""'/"'"A..__ _________ _ Signed P-A&u< 'l'.l..f! 7 Owner or Owner's Designee, True Date {7---i.3 '19 7(' CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Omier's Report during the period f o -2.. 7-z*;rl I "'2..
- L 7 -.f'jtlnd state that to the best of my knowledge and belief, the Owner has perfom1ed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and col'l'eCtive measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engr. Assn. L<=> Sp V/ elf"' ""y <.J S-Y.J / Inspector's Signature National Board, State, Province, and Endorsements Date /'2.. ..... 2 7 19 'i'</
- *
- FORM NIS-2 OWNER'S REPORT FOR REP Ams OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 22 1994 Name PO Box 236. Hancocks Bridge, NJ 08038 Address 2. Plant Salem Generating Station Unit# --=2'---------------
Name PO Box 236. Hancocks Bridge. NJ 08038 CJP S94-l45 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Type Code Symbol Stamp A-=-------- Name Authorization No. -----"N'""/_,_A....._ _____ _ PO Box 236. Hancocks Bridge, NJ 08038 Expiration Date ___ _...N"""/._,A,__ _____ _ Address 4. Identification of System Main Steam -Generator .3 S (f IV'£-5. (a) (b) Applicable Construction Code ANSI B31. 7 19 _§2_ Edition, NI A Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Snubber Rexnord 90057-31 NIA NIA 1975 Replacement No .. 7. Description of Work Removed snubber and n;placed same with like-in-kind.
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other 0 Pressure NIA psi Test Temp. NIA OF NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) 111is Fom1 (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Rsmlacement of the ASlVIE Code, Section XI repair or replacement conforms to the rules Type Code Symbol Stamp __ --'-N=/A'-=-------------------------------
Certificate of Authorization No. _________ _ Expiration Date __________ _ Signed Jl...A..uu.( .d V' Owner or Owner's Oesignee. nif'e Date / -i. -:l ) , 19 9 Y' > CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period /<7-'-7-7 '1fo / 2.->-L 7 ..:...7.c/, and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this, Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. /42-o.S,,J18.!*1,£ '-<.}_;-Yr.J/ Inspector's Signature National Board, State, Province, and Endorsements Date / '--L 7 19 2' :Y
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS
_As Required by the Provisions of the ASME Code Section XI I. Owner Public Sen.rice Electric & Gas Co. Date November 25 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 2EC-3327. WO 941013148. CJP S94-147 Address Repair Organization P.O. No., Job No., etc. 3. Work Perfonned by_,P-"S=E=&=G,.,__ ______ _ Type Code Symbol Stamp A..lo------- Name Authorization No. __ ___,_N.:..:.l"""'A,__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ _......,N!.!..!/A_.__ _____ _ Address 4. Identification of System Reactor Coolant #22 Reactor Coolant Pump Nuclear Class II WEspec. 5. (a) Applicable Construction Code 676508 19_Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 _Jlli._ 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement 2RCE5Pump Westinghouse 2-NIA #22RCP 1968 Replacement 618J815GOI -* 7. Description of Work Welded cap on pressure tap spools. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure r:J. Other Pressure NOP psi Test Temp. NOT OF System Inservice Test ASME Code Stamped (Yes or No) N NOTE: Supplemental sheets in fonn oflists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) maybe obtained from the Order Dept, ASME, 345 E. 47th St, New York, N.Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI repall" or replacement Certificate of Authorization No. _
__________ Expiration Date ___ _________ _ Signed .c(.,, Owner or Owner's Dclignee, Title Date I C CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and emploxed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period / 0 P Wr to I and state that to the best of my knowledge and belief: the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, '"'"ction XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn . P,, 2L? 5 6 ,J 14Jf' JS .u'at:t';;-,) Inspector's Signature National Board, State, Province, and Endorsements Date /4*/ 7 19 {-
- *
- FORM NIS-2 OWNER'S REPORT FOR REP Ams OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI l. Owner Public Service Electric & Gas Co. Date November 25 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _l _of_.__ __________
_ Address 2. Plant Salem Generating Station Unit# --=2 ____________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 2EC-3327. WO 941013152. CJP S94-l48 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_...P-=S=E=&..,G"--------- Type Code Symbol Stamp Name Authorization No. _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ----'-'N..,IA_._ _____ _ Address 4. Identification of System Reactor Coolant #23 Reactor Coolant Pump Nuclear Class II WEspec. 5. (a) Applicable Construction Code 676508 19_ Edition, NI A Addenda, NI A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufactw*er Serial No. Board Identification Built Replaced, or No. Replacement 2RCE7Pump Westinghouse 3-NIA #23 RCP 1968 Replacement 618J815G01
- 7. Description of Work Welded cap on pressure tap s.pools. 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure 2'.l Other [jl_ Pressure NOP psi Test Temp. NOT OF System Inservice Test ASME Code Stamped (Yes or No) N NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided ( 1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St, New York, N. Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI repmr or replacement Certificate of Authorization No.
_________ Expiration Date Signed ---*-" *7 Owner or Owner's Destgnee, 7 Date /-J , 19 t'S: CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Ins. Co. of MA have inspected the components described in this Owner's Report during the period / d /J !fr( to t/: 1/f J:'and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. _________ Commissions f4 2<?S(.IU;BSIJ vryj-/ Inspector's Signature National Board, State, Province, and I 19 rs
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAms OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date Januruy 9. 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Unit# ----=2.__
___________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 2EC-3327 WO 941013154 CJP S94-149 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_.P_.S=E=&=G=-------- Name Type Code Symbol Stamp """N"""I Authorization No. PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ Address 4. Identification of System Reactor Coolant #24 Reactor Coolant Pump Nuclear Class II WE-Spec 5. (a) Applicable Construction Code 676508 19_ Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer
- Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2RCE9Pump Westinghouse 4-NIA #24RCP 1968 Replacement N 618J815G01 0 -* 7. Description of Work Welded cap on pressure tap Sl?OOls. 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) TI1is Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Backf *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASlvIB Code, Section XI
- repall" or replacement Certificate of Authorization No. _ _,N.,,l""A..__
_________ Expiration Date --'N!..!/,,..A..__ _________ _ Signed
- Owner or Owner's Des1gnee;Titicf
---, Date / CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owners Report during the period J 0 /31/ 'fJ.'{'to '/ "i/ 9 C and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn . ... _ .... **"'""""'-----=--------Commissions Inspector's Signature National Board, State, Province, and Endorsements Date _...J_,_/_7':!.....4--/ ___ 19 'l s-J I
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAms OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date November 25 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 2EC-3327.
WO 941013139. CJP S94-150 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by'"""P-=S=E=&=G,.__ ______ _ Type Code Symbol Stamp ..... N""'/A_.__ _____ _ Name Authorization No. __ _.._N""'IA:..:..... _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ No..:.:..:./A...__ _____ _ 4. Identification of System Reactor Coolant #21 Reactor Coolant Pump Nuclear Class II WEspec. 5. (a) Applicable Construction Code 676508 19_ Edition, --1::Y.A_ Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No . Board Identification Built Replaced, or No. Replacement 2RCE3 Pump Westinghouse 1-NIA #21 RCP 1968 Replacement 618J815GOI
- 7. Description of Work Welded cap on pressure tap fil?Ools.
- 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure 13 Other gi Pressure NOP psi Test Temp. NOT OF_ System Inservice Test AS:ME Code Stamped (Yes or No) N NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) infonnation in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) TI1is Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, N. Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the AS:ME Code, Section XI repall" or replacement Certificate of Authorization No. _
Expiration Date __,,N""/"'"A....._ _________ _ Date i-r , 19 9=5= CERTJFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employ . by 4al Ins. Co. of MA have inspected the components described in this Owner's Report during the period / 0 J to 4L_7/5;£ , and state that to the best of my knowledge and belie!'; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any per.;onal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn . . __ -"_,_-=_ ----Commissions r° 4-u;;S ).) I l.J r IS ).} r I Inspector's Signature National Board, State, Province, and Endorsements Date ;jq/ 19 95-
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 2 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _l _of_..__ __________
_ Address 2. Plant Salem Generating Station Name Unit# __,2.__ ____________ _ PO Box 236. Hancocks Bridge, NJ 08038 WO 970327005 CJP S94-16 l Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp _____ _ Authorization No. __ PO Box 236, Hancocks Bridge, NJ 08038 Expiration Date ___ ____._N.!!./.!..CA.___ _____ _ Address 4. Identification of System Chemical Volume Control 22CV157 Valve Nuclear Class II WEspec. 5. (a) Applicable Construction Code E-676281 19_ Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 __£Q__ 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement 22CVI57 ITT Grinnell NIA NIA 7166-63 NIA Replacement Valve --7. Description of Work Replaced bonnet assemblv.
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic D Nominal Operating Pressure l1l Other Pressure NOP psi Test Temp. NOT OF System Inservice Test ASME Code Stamped (Yes or No) N NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( 1) size is 8 1 /2 in. x 1 1 in., (2) inf01mation in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Fonn (E00030) may be obtained from the Order Dept., 345 E. 47th St., New York, N.Y., 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI repair or replacement conforms to the rules Type Code Symbol Stamp Certificate of Authorization No.
Signed LL ,,/ fl -cP+/-<y/l.. or Owner's Expiration Date _N""""'/A_,_ __________ _ Date / 2 , 19 9,e CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period to /J-S*'it/ and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinatio.ns and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. __ Commissions _iJ_S_3_}_} ______ _ j Inspector's Signature National Board, State, Province, and Endorsements Date----'-'-/ l"'-/-S ___ 19 .?Ji_
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 23 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_
Address 2. Plant Salem Generating Station Unit# --=2...._ ___________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 WO 950221024 CJP S94-166 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Type Code Symbol Stamp Authorization No. Name PO Box 236, Hancocks Bridge. NJ 08038 Expiration Date _____ _ Address 4. Identification of System Service Water 2CVE39 Pump Nuclear Class II WE-Spec 5. (a) Applicable Construction Code 676427 19_ Edition, NIA Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2CVE39 Oil Westinghouse 9415066-01 55220 PN 5-142-05-1993 Replacement y Cooler 016-042 -* 7. Description of Work Replaced charging pump oil cooler. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure CM-Other Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( l) size is 8 I 12 in. x 11 . in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the AS:NIE Code, Section XI repair or replacement conforms to the rules Certificate of Authorization No.
__ __________ _ Expiration Date ___________ _ Signed 4_._,_ "" Owner or Owner's Des;gnee;Title Date I "2--I ' 19 CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period I 0 -1. -/
- 7* -1" to i
/c;;: ';t/. and state that to the best of my knowledge and belief; the Owner has perfonned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection ..
-=-------Conunissions Inspector's Signature Date / L -L 7 Factory Mutual Engr. Assn . -L o J ,,.J/ (> s-1 ..S µ:::;-c/j (" National Board, State, Province, and Endorsements
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 27 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name Unit# _..=2'--------------
PO Box 236. Hancocks Bridge. NJ 08038 WO 950103003 CJP 94-179 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp .o..;N"""'IA-"-------- Authorization No. __ _....N_,,/.._A....._ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System Safety Injection 2SJ150 -Check Valve -Nuclear Class I WE-Spec 5. (a) Applicable Construction Code G-676241 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement 2SJ156 Velan Bl03114 NIA NIA 1987 Replacement Check Valve Bl 3M .. ASME Code Stamped (Yes or No) N 7. Description of Work
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 121' Other ,gi Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( 1) size is 8 112 in. x 11 in., (2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. * (12182) TI1is Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th SL, New York, N. Y. 10017 '
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the AS:ME Code, Section XI repaU"orreplacement Certificate of Authorization No. ---'N'"""'"IA_,__
__________ Expiration Date ---'N'"'"/"'"A_,__ _________ _ /.1Ne/Z.. Date *s AN. '5 , 19 7 S CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Cp. of MA have inspected the components described in this Owner's Report during the period / f-7,,.. qt{ to /-J 0 ..-f (,and state that to the best of my knowledge and belie( the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. Date __ 199<'
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI !)ate De1,;ember
- 27. l 99..+ Sheet _l _or_,__ __________
_ ,\Jdr'"' 2. Plant Salem Cienerati11L! Station llnit # 2 '.\arm ..
- WO 930327065 UP 94-182 Repair Organization I'.< l. :-;o .. Job :-;o ..
- 3. Work Pe1formed
_________ _ Type Code Symbol Stamp o..;N::..:IA_,__ _____ _ Name Authorization No. PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ __,_N""'IA'-"--------- Address 4. Identification of System Chemical Volume Control -2CV274 Check Valve -Nuclear Class I WE-Spec 5. (a) Applicable Construction Code G-676241 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement 2CV274 Velan B10-31114B NIA NIA 1988 Replacement Check Valve !3M -* 7. Description of Work Replaced valve disc. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure p Other Pressure NOP psi Test Temp. NOT OF System Inservice Test ASME Code Stamped (Yes or No) N NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. * (12182) 111is Fann (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, N. Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI repatr or replacement conforms to the rules Type Code Symbol Stamp ___ N'""'"'"/A_,__
___________________________ _ _ Expiration Date f?t.tM Designee, Title CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period / 1-S: f '( to /-5 0 -l!j"".f'" and state that to the best of my knowledge and belief; the Owner has perfonned examinations and taken corrective measures described in Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. National Board, State, Province, and Endorsements / Date /-1 () 19<(
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAJRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 12 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name Unit# _,.,,2 ________
PO Box 236. Hancocks Bridge. NJ 08038 WO 941025116 CJP S94-186 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_.,.P--"S=E=&=--'G'"'"--------- Type Code Symbol Stamp N"-"-"/ A_,___ _____ _ Name Authorization No. __ ___.N'"""/..._A..__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System Residual Heat Removal 2RHE4 Heat Exchanger Nuclear Class II WESpec. 5. * (a) Applicable Construction Code G-676454 Rev. I 19_ Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- ASME III, 1968 Ed. ASME VIII Div. I Class 3 1968 6. Identification of Components Repaired or Replaced and Replacement Components
- 7. 8. Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2RHE4Heat Engineers
& S-15860-D 1123 #22 RHR 1969 Replacement y Exchanger Fabricators Heat Exchanger -* Description of Work ,.,g,,_. ------------------------- Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in fo1m oflists, sketches, or drawings may be used, provided (I) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Repc.rts to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI repall" or replacement conforms to the rules Certificate of Authorization No. --'N'-'l:..:.A""-----------
Expiration Date _N'"""'/A_,_ __________ _ Signed Date / ..Z.-'/ Owner or Owner's Designee, Title 94* , 19 _ _.L.L__ CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period / J 'J'/ to / 2--/ '2..-'i Z-: and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures in this Owner's Report in accordance with the requirements vf the ASME Code, _ .n XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corre£tive measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connecte.d with this inspection. Factory Mutual Engr. Assn . __ <g _________ Commissions Z.P.5t;J,,3s1'.J .dry*.:-; Inspector's Signature National Board, State, Province, and Endorsements Date /'11.. -/ Z.... 19 7'V 7
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date Name PO Box 236. Hancocks Bridge, NJ 08038 Address 2. Plant Salem Generating Station Unit# __,2,.__ ____________
_ Name PO Box 236. Hancocks Bridge, NJ 08038 WO 921007017 CJP S94-l 87 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp Authorization No. PO Box 236, Hancocks Bridge, NJ 08038 Expiration Date ___ _..!.,N!!../Aw._ ______ _ Address 4. Identification of System Chemical Volume Control 2CV166 Valve Nuclear Class II W Espec. 5. (a) Applicable Construction Code E-676281 Rev. 2 19_ Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacttn*er Serial No . Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2CV166 ITT Grinnell 91590117, NIA NIA NIA Replacement N Valve 7. Description of Work
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure Other Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the made in the report are correct and this Replacement of the AS:ME Code, Section XI Teparr or replacement conforms to the rules Certificate of Authorization No.
__________ Expiration Date __________ _ Signed .d.UL--4 Owner or Owner's Designee, Title Date I;).--,-'19 P,0 CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel lm;pectors and the State or Province of New Jersey and employed by Arkwnght Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period I I-<r q 'i to a , r-1 v , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. . l_ / ,f A 1'J_.] *73 --'=::;<-... _ _,,(&yZ-c"""".c;_-=::...._-* ___ Commissions __ /V_, _________________ _ In;pector's Signature National Board, State, Province, and Endorsements Date ___ __ 19 Ci L/
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 27 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name Unit# _..._2 ____________
_ PO Box 236. Hancocks Bridge. NJ 08038 WO 940926176 c#94-190 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp """'N .... IA....._ _____ _ Authorization No. PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ N=-=IA_.__ _____ _ Address 4. Identification of System Residual Heat Removal 2RH26 Valve -Nuclear Class I WE-Spec 5. (a) Applicable Construction Code G-676258 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement 2RH26 Valve Velan ll4863 NIA NIA 1967 Replacement ' ; -* 7. Description of Work Re.vlaced valve bolting and performed weld re.vair to leak off line. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure )l" Other j!J Pressure NOP psi Test Temp. NOT OF System Inservice Test ASME Code Stamped (Yes or No) N NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided ( 1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF C01\1PLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI repair or replacement Certificate of Authorization No. _
__________ Expiration Date __,N .... l"'"A..._ _________ _
- Owner or Owner'illeSiglle;Titie Date/ -3 ,19 Pr CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period i I -I/-f'j :Ito I -r-zr. and state that to the best of my knowledge and belie( the Owner has perfom1ed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engr. Assn. fk1 Commissions & 2J::> ;f //..)I ($,S r .... J Y.3" / Inspector's Signature National Board, State, Province, and Endorsements Date I -'"( -9 S -19 9 J
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date December 27. 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of__.,__ _________
_ Address 2. Plant Salem Generating Station Name Umt#__.2,._ __________ _ PO Box 236. Hancocks Bridge. NJ 08038 WO 930327066 CJP 94-191 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by....,P_..S=E=&=G.__ _____ _ Type Code Symbol Stamp .... N""'IA-=-------- Name Authorization No. ___ N ........ IA......_ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ __,N..,.l .... A....__ _____ _ 4. Identification of System Chemical Volume Control -2CV78 -Valve -Nuclear Class I WE-Spec S. (a) Applicable Construction Code G-67624 19 NIA Edition, .NlA._ Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ,Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement 2CV78 Velan BI0-3114B NIA NIA 1988 Replacement Check Valve !3M --* ASME Code Stamped (Yes or No) N 7.
- 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure Other JP Pressure NOP psi Test Temp. NOT OF System lnservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (I) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Fonn (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th SL, New York, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI repair or replacement Type Code Symbol Stamp ___
______________________________ _ _ _,N""'/_,_A....._ __________ Expiration Date __,N ... l ... A..__ _________ _ 'Prtll\JCl e/l Date 19 Owner or Owner's Designee, Title CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins.,Co. of MA have inspected the components described in this Owner's Report during the period//-//- £Y to/-3/-'1S and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. _C-.L--___ Signature National Board, State, Province, and Endorsements Date /-1 / 19 if< ----'---'------
- *
- FOAAI NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACElWENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 Address 3. Work Performed Name PO Box 236. Hancocks Bridge. NJ 08038 Address Date Januarv 23 1995 Sheet _I_ of___.,__
_________ _ Unit# ___,2=--------------- S94-l 92 WO 941024024 Repair Organization P.O. No., Job No., etc. Type Code Symbol Stamp ""'N""'/A....._ _____ _ Authorization No. __ _____ _ Expiration Date ____ N ........ IA..._, _____ _ 4. Identification of System Reactor Coolant System. Nuclear Class I. #21 Steam Generator
- 5. (a) (b) Applicable Construction Code ASME Sect. ill 19 ..Qi_ Edition, Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer Component Manufacturer Serial No. Bolt Westinghouse PO 281682 Elect. Corp. HT#71014 --National Other Board Identification No. NIA NIA Year Repaired, Built Replaced, or Replacement 1988 Replacement S>1J$ .QT/<15 5" ASME Code Stamped (Yes or No) No 7. Description of Work Replace #21 Steam Generator Cold LegManwayBolts 21C$ & 21C8 in kind from folio. 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure D Other Ji!! Pressure NOP psi Test Temp. NOT OF NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017 "-**
- FORM NIS-2 (Back) * . :;
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this RSI?lacement of the AS:ME Code, Section XI rcparr or replacement conforms to the rules Certificate of Authorization No. _ ..... N""l.._A,__
__________ Expiration Date ____________ _
- er or Owner's Des1gnec, Title Date __
19 f CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period //-/}-C/tf to / 'j.. 7 'Cf):;r and state that to the best of my knowledge and belief; the Owner has pertormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injuiy or property damage or a loss of any kind arising from or connected with this inspection . Factory Mutual Engr. Assn. (} {. C-ve_ Commissions J_* ------T IJlSPect<;r's Signature National Board, State, Province, and Endorsements / Date /-2 7 19<?.>
- *
- FORl\'I NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the Code Section XI I. Owner Public Service Electric & Gas Co. Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 Address Date Januarv 23 1995 S94-193 WO 941024025 Repair Organization P.O. No., Job No.,
- 3. Work Performed by_,.P_..S""E""&.,,,G"---------
Type Code Symbol Stamp ....,N ...... IA_,,__ _____ _ Name Authorization No. __ __,,N=IA:...o..... _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System Reactor Coolant Svstem. Nuclear Class I. #22 Steam Generator
- 5. (a) (b) Applicable Construction Code ASME Sect. III 19 ..Qi_ Edition, S66 Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement Bolt Westinghouse PO 281682 NIA NIA 1988 Replacement Elect. Corp. HT #71014 .. 7. Description of Work Re.place #22 Steam Generator Hot Leg Manway Bolt 22H4 in kind from folio. 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure 0 Other Pressure NOP psi Test Temp. NOT DF ASME Code Stamped (Yes or No) No NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( 1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order DepL, ASME, 345 E. 47th SL, New York, N. Y. 10017
- FORM NIS-2 (Back) *
- 9. Remarks ____________________________________
_ Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the *statements made in the report are correct and this fumlacement conforms to the rules of the ASME Code, Section XI repair or replacement TypeCodeSymbolStamp __ ___________________________ _ Certificate of Authorization No. _ __________ Expiration Date _________ _ Signed
- Owner or Owner's besignee:tide Date ( -2... :;----* '19 9 s-CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period //-/ k tf '-/ to /-f, J .,-f), and state that to the best of my knowledge and belief: the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engr. Assn. St(.i*gna' Commissions
/
- National Board, State, Province, and Endorsements
__ 19 C/)
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEIVIENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date Januarv 23 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of ____________
_ Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 S94-194 WO 941024023 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_..P ..... S=E=&=G"'--------- Type Code Symbol Stamp Name Authorization No. __ __._N""'/A....._ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ N,,._..,_/A_.__ _____ _ Address 4. Identification of System Reactor Coolant System. Nuclear Class I. #23 Steam Generator
- 5. (a) (b) Applicable Construction Code ASME Sect. III 19 ..22._ Edition, __s§Q_ Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 .]§___ 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built. Replaced, or No. Replacement Bolt Westinghouse PO 281682 NIA NIA 1988 Replacement Elect. Corp. HT #71014 -* 7. Description of Work Replace #23 Steam Generator Cold Leg Manway Bolt 23Cl in kind from folio. 8. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other Pressure NOP psi Test Temp. NOT OF ASME Code Stamped (Yes or No) No NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. -(12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the AS:ME Code, Section XI repall" or rcpaccmenf Certificate of Authorization No. _ _,N""'"'"IA_,__
__________ Expiration Date Signed er or Owner's 1gnee, Till Date _ J,__ ___ , 19 Y. 5 -CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ofNew Jersev and employed by Arkwright.Mutual Ins.Ro. of MA have inspected the components described in this Owner's Report during the period / /-!J...-tf </ to /-2 J 4 f and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in th;" Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. f, Commissions AJ:JJJJ National Board, State, Province, and Endorsements ../ J_? __ 19 Cfj
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date February 13. 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _l _of_.__ __________
_ Address 2. Plant Salem Generating Station Unit# Name PO Box 236, Hancocks Bridge. NJ 08038 d "" WO #970113001 CJP 1 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_,.P-=S=E=&=G"'--------- Type Code Symbol Stamp .... N...._IA...__ _____ _ Name Authorization No. __ __,_N"""l,_,A,__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date _____ _ Address 4. Identification of System Chemical Volume Control -2CV115 Valve -Nuclear Class II WE-Spec 5. (a) Applicable Construction Code G-676241 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2CV115 Crosby N69963 NIA NIA NIA Replacement N Relief Valve 0012 7. Description of Work
- 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, N.Y. 10017
- FORM NIS-2 (Back) *
- 9. Remarks WO 970113001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules repatr or replacement Certificate of Authorization No. _ _,N'-'/'""A......_
__________ Expiration Date ___,N:..;,1..,_A......_ _________ _ Signed L/A.J_,-<<-,&; d"71= ' Owner or Owner's Date ;}--I Lt '19 ?..s= CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ofNew Jersey and employed by Arkwright Mutual Ins. Ca. of MA have inspected the components described in this -_/ Owner's Report during the period I /-17, 'ftf to J-Z' 1'J , and state that to the best of my knowledge and beliet: the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. __ Commissions _IZA_u_J'---7-"-'J ____ _ / 111S;Ct(){J;si;atllre National Board, State, Province, and Endorsements Date 19 9 .('
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 Date December 2. 1994 Unit# 2 . 5"\l\-2.\
1.. "\'i'-1 WO 941101294 CJP S94 219 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp ""'N"""IA....__ _____ _ Authorization No. PO Box 236. Hancocks Bridge NJ 08038 Expiration Date ___ Address 4. Identification of System Containment Spray 21 CS48 Valve Nuclear Class II WEspec. 5. (a) ApplicableConstructionCode E-676291 19_Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 21CS48 Aloyco Div./ 70A6295 NIA NIA NIA Replacement N Valve Wolworth Co. -* 7. Description of
- 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure i1f' Other .g Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) lbis Fonn (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI repatr or replacement conforms to the rules Certificate of Authorization No. NIA Expiration Date __.N""/""A....._
_________ _ Signed L ,,/ ,./, ..,.. :.,1 Date / 2 -o :t..-..,. * 'ff::::; or Owner's Designee, Title ?7"" ,19 9Y CERTIFCATE OF INSERVICE INSPECTION undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period //-/ d'! ?% / e..-'--9""r.and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, XI. By Signing this certificate neither the Inspector nor his employer makes any warranty; expressed or implied, concerning the examinations and con-ective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. Commissions A c..,o..S A.// <1 S I ..J d..JY::J / Inspector's Signature National Board, State, Province, and Endorsements' Date 19 9 7:
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 2 1994 Name PO Box 236. Hancocks Bridge, NJ 08038 Sheet_. _l _of_,__ __________
_ Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge, NJ 08038 WO 941101294 CJP S94-219 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp Authorization No. _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System Containment Sprav 21 CS48 Valve Nuclear Class II WEspec. 5. (a) Applicable Construction Code E-676291 19_ Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 21CS48 Aloyco Div./ 70A6295 NIA NIA NIA Replacement N Valve Walworth Co. -* 7. Description of Work--"'R=e+p=la=c=e=d_,.b=o=lt!=*n,.,g"-.
- 8. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure Er. Other ,g Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) info1mation in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) 111is Fonn (£00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the made in the report are correct and this Replacement of the ASME Code, Section XI reparr or replacement conforms to the rules Certificate of Authorization No.
__________ Expiration Date Signed L Owner's Designee, Title I' I'
- Date / 2 -o :::.._.. ,19 9Y CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arbvright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period / / -/ 9'%:, / C:.. -f' and state that to the best of my knowledge and belieC the Owner has perfom1cd examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
c----... \ Factory Mutual Engr. Assn. ,d""0' Comrni,,iom A L-o.S "-A./; <1 S i 0 dJ:Y::J / ' National Board, State, Province, and Endorsements Inspector's Signature Date __ __ 19 7' 7:'
- *
- FORl\'I NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACE:MENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date Januazy 10. 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of___,..__
_________ _ Address 2. Plant Salem Generating Station ____________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 WO 941122021 CJP S94-221 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp Authorization No. ----=-N..._/ A'-"------- PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ N ........ IA...._ _____ _ Address 4. Identification of System Reactor Coolant 2RCE I Reactor Nuclear Class I WE-Spec *5. -(a) Applicable Construction Code 676559 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement Reactor Stud Westinghouse NIA NIA NIA 1969 Replacement .. ASME Code Stamped (Yes or No) N 7. Description of Work ... e,.,,ac""to,..r_,stu=d,._.
- 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) 111is Fonn (E00030) may be obtained from the Order DepL, ASME, 345 E. 47th SL, New York, N.Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Rsmlacement conforms to the rules of the AS:ME Code, Section Xl rcparr or replacement Certificate of Authorization No. __
_________ _ Expiration Date _________ _ Signed L.:.<<.4,, fJ .. ....( ,"' Owner or Owner's besigncc, Titre Date I /c , 19 9.r-CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Ownei'sReportduring the period I z/ 2 / q4 to 2 I I 7 /95. and state that to the best of my knowledge and belief; the I . Owner*has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective* measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn .
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 27 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 J WO 941223002 CJP 94-224 DR 941223002 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by...,P...,S=E=&=G=--------
Type Code Symbol Stamp '""'N"""I A-=-------- Name Authorization No. __ _____ _ PO Box 236. Hancocks Bridge, NJ 08038 Expiration Date Address 4. Identification of System Main Steam 21 MS46 -Valve -Nuclear Class I I 5. (a) (b) Applicable Construction Code ASME III 19..fil._ Edition, W82 Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 _M._ 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement 21MS46 Velan Bl4-2114-NIA NIA 1984 Replacement Valve 027S l --7. Description of Work Replaced bonnet to body bolting. 8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Other tG Pressure NOP psi Test Temp. NOT OF System Inservice Test ASME Code Stamped (Yes or No) N NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Fonn (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., York, N.Y. 10017 . I
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Rwlacement conforms to the rules of the ASME Code, Section XI repatr or replacement Type Code Symbol Stamp __
Certificate of Authorization No. NI A Expiration Date _________ _ Signed /f_ * ** Date I -3 " Owner or Owner's Designee, Title ' , 19 e;;t: CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period i 1. -I -1 '{. to / / t /.:z J , and state that to the best of my knowledge and belief: the
- Owner has performed examinations and taken corrective measures described in this Ownet's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engr. Assn. _/14' ___ Commissions 8 Z-= 5 G: U / '3' .)/ j A-).)yJ / Inspector's Signature National Board, State, Province, and Endorsements
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 21 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Unit#
Name PO Box 236. Hancocks Bridge, NJ 08038 WO 941120016 CJP S94-225 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp Authorization No. __ PO Box 236. Hancocks Bridge, NJ 08038 Expiration Date ___ __,_N"""/"'""'A..._ _____ _
- 4. Identification of System Reactor Coolant 2PR3 Valve Nuclear Class I WE-Spec 5. (a) Applicable Construction Code 676279 19 N/A Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 _]Q_ 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer I National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2PR3 Valve Crosby RV2-8010A NIA NIA 1971 Replaced N --7. Description of Work Replaced valve with valve serial number RV-464-PSE and replace bolting. 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure fl Other D Pressure NOP psi Test Temp. NOT OF System Leakage Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) 111is Fonn (E00030) may obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI reparr or replacement conforms to the rules Certificate of Authorization No. _ _,N'""/""A..___
________ Expiration Date Signed 4-a "' Owner or Owner's T'e Date _ _....,rL._- __ g ____ , 19 't' £= CERTIFCATE OF JNSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co;-of MA have inspected the components described in this Owner's Report during the period /2--q { to J -,/CJ....-t;"{ , and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. Commissions ___ _ T Inspector's Signature National Board, State, Province, and Endorsements
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 21 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Unit# __,2.,_ ____________
_ Name PO Box 236. Hancocks Bridge. NJ 08038 WO 941119007 CJP S94-226 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Type Code Symbol Stamp "'"'N ..... IA....__ _____ _ Name PO Box 236. Hancocks Bridge. NJ 08038 Address Authorization No. __ Expiration Date ------""N .... IA'-"--------
- 4. Identification of System Reactor Coolant 2PR4 Valve Nuclear Class I WE-Spec 5. (a) Applicable Construction Code 676279 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2PR4 Valve Crosby RV-468-NIA NIA 1971 Replaced N PSE -* 7. Description of Work Replaced valve with valve serial number RV2-80 l OB and replace bolting. 8. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure NOP psi Test Temp. NOT OF System Leakage Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Fonn (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- 9. *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI reparr or replacement Certificate of Authorization No. _
__________ Expiration Date _________ _ Signed 7 Owner or 0wne?SDeS(gllee;Title Date 3 -tf , 19 f<"--CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwri ht Mutual Ins. o. of MA have inspected the components described in this Owner's Report during the period /.. . J (' to f -/ tJ 4 5 . and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. __ _Commissions ______ _ Inspector's Signature National Board, State, Province, and Endorsements _./ Date J-/ U 19 q)
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 21 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of _ _,__ __________
_ Address 2. Plant Salem Generating Station Name Unit# __,2.._ ____________ PO Box 236. Hancocks Bridge. NJ 08038 WO 941120015 C-:Jf 59. f-22, 7 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp Authorization No. __ ___._N=IA'-"-------- PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ N'"-"--'-IA_._ _____ _ Address 4. Identification of System Reactor Coolant 2PR5 Valve Nuclear Class I WE-Spec 5. (a) Applicable Construction Code 676279 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 _]Q_ 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2PR5 Valve Crosby RV2-8010B NIA NIA 1971 Replaced N I -" 7. Description of Work Re,Placed valve with valve serial number RV-28010A and replace bolting. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure Other D Pressure NOP psi Test Temp. NOT OF System Leakage Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number.of sheets is recorded at the top of this form. (12182) TI1is Fonn (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI repair or replacement conforms to the rules Type Code Symbol Stamp __ __,_N"""/'"""'A'-------------------------------
Certificate of Authorization No. __________ _ Expiration Date _N=-=/A'-'----------- Signed P /f. ..,. Owner or Date J-/, '19 9.s-CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Ce:"of MA have inspected the components described in this Owner's Report during the period 0-')" --t(t( to f -I 0 -Cf S-: and state that to the best of my knowledge and belief; the Owner has perfom1ed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. _Commissions ] _____ _ T Inspector's Signature National Board, State, Province, and Endorsements Date ___ f_--l_tJ __ 19
- *
- FORM NIS-2 OWNER'S REPORT FOR REP .Ams OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date December 22 1994 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _1 _of_.__ __________
_ Address 2. Plant Salem Generating Station Name PO Box 236. Hancocks Bridge. NJ 08038 WO 930427021 CJP S94-228 Address Repair Organization P.O. No., Job No., etc. 3. Work Petformed by'""P-"S=E=&=-G'"'--------- Type Code Symbol Stamp ,._N""'/ A_,__ _____ _ Name Authorization No. __ __.N"""l_,_A.__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System Chemical Volume Control 2CV283 Valve -Nuclear Class II WE-Spec 5. (a) Applicable Construction Code 676281 Rev. 2 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2CV283 ITT Grinnell SD-C-NIA NIA 1988 Replacement N Valve 112277 -* 7. Description of Work Replaced valve bonnet and bolting. 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure gJ Other Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided ( l) size is 8 112 in. x 11
- in., (2) informatiorrin*items l through*6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Fonn (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Back) * * ,,Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement of the ASME Code, Section XI repair or replacement conforms to the rules Type Code Symbol Stamp __ __,_N"""/""'A'-------------------------------
Certificate of Authorization No. Expiration Date Signed
- Owner or Owner's Date l Z -2. ..J , 19 7 7 CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwrilht Mutual Co. of MA have inspected the components described in this Owner's Report during the period / Z -Z.-9 '7' to . 'hj2? /r 7 . and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this 'owner's Report in accordance with the requ,irements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engr. Assn. ____ Commissions A.// rJS'/J it.l.S-7..T,t Inspector's Signature National Board, State, Province, and Endorsements Date _/_2-_-_l_7 ___ 19 _j
- -* FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co.
________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of_..__ __________ _ Address 2. Plant Salem Generating Station Unit# -=2 _____________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 WO 941130175 CJP S94-230 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Type Code Symbol Stamp .._,Nu.I Authorization No. Expiration Date Name PO Box 236. Hancocks Bridge. NJ 08038 Address 4. Identification of System Pressurizer pipe hanger -Nuclear Class II S-C-MBOO-:tvIDS-0043
- 5. (a) (b) Applicable Construction Code Rev. 0 19_ Edition, NIA Addenda, NIA Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, Component Manufacturer Serial No. Board Identification Built Replaced, or No. Replacement Variable Pipe PSE&G NIA NIA 2C-PRH-205 1977 Replacement Support -* 7. Description of Work Replaced 1/2" rod weldless eye.and nuts on support 2C-PRH-205.
- ; 8. Tests Conducted
Hydrostatic D Pneumatic D Nominal Operating Pressure D ASME Code Stamped (Yes or No) N Other D Pressure __ psi Test Temp. __ OF Pre-Service VT-3 Exam was Performed NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. * (12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Back) *
- Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in.the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI repall' or replacement Certificate of Authorization No. _
Expiration Date Signed ,L.Ld.,_44 4 Owner or Owner's Desig;lee;Title Date ___ , 19 p.,r CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwri ht Mutual Ins. . of MA have inspected the components described in this Owner's Report during the period /1. i/ to -] -Gt and state that to the best of my knowledge and belief; the Owner has performed and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or conneCted with this inspection. Factory Mutual Engr. Assn. u ___ Commissions_IJ_,.__J..;:;._} 1_J ____ _ Signature National Board, State, Province, and Endorsements _.,/ Date 2 -19 Cf 5 ...
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date Februruv 13 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheer_l _of__,,__
_________ _ Address 2. Plant Salem Generating Station Unit# -=2 ____________ _ Name PO Box 236. Hancocks Bridge. NJ 08038 WO #941230091 CJP S94-240 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_,.P-=S=E=&=-G"'--------- Type Code Symbol Stamp Name Authorization No. __ __._N"""IA......_ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ _,N'"""/'-'-A....__ _____ _ Address 4. Identification of System Reactor Coolant 2PR5 Valve -Nuclear Class I 'j/_E-Spec
- 5. (a) Applicable Construction Code 676279 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2PR5 Valve Crosby RV-2-8010-NIA NIA 1971 Replacement N A-PNJ Studs (12) Allied Nut & HT NIA NIA NIA Replacement N Bolt Co. #8861963 Nuts (24) Allied Nut& HT #02293A NIA NIA NIA Replacement N Bolt Co. 7. Description of Work Replaced valve and bolting. 8. Tests Conducted:
Hydrostatic D Pnewnatic D Nominal Operating Pressure D Other D Pressure NOP psi Test Temp. NOT OF System Leakage Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the nwnber of sheets is recorded at the top of this form. -(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
- FORMNIS-2 (Back) *
- 9. Remarks WO 941230691 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME C<?de, Section XI Replacement conforms to the rules repa1r or replacement Certificate of Authorization No. NIA Expiration Date Signed Date 2--/y* "" Owner or Owner's De;;g;;ee;Title
.,...-. CERTIFCATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Or of MA have inspected the components described in this Owner's Report during the period ( J -JC _qlj to J -.../ J -1..> . and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. /" Date __ _..,}"----! .J_,,,,,-__ 19 q 5 Factory Mutual Engr. Assn.
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Name End of Buttonwood Rd. Hancocks Bridge,NJ Address 2* Plant __ s_a_l_e_m_N_u_c_l_e_a_r_G_e_n_e_r_a_t_i_*
n_g_S_t_a_t_i_o_n_*: _ Name End of Buttonwood Rd.,Hancocks Bridge,NJ Address 3. Work Performed by __ P_S_E_&_G _____________ _ Name End of Buttonwood Rd.,Hancocks Bridge,NJ Address Date __ s_e_p_t_e_m_b_e_r __ 2_3_,_1_9_9_3 _____ _ 1 1 Sheet ____ of ____________ _ Unit __ 2 ________________ WO #921106133 CJP #PS93-002 Repair Organization P.O. No., Job No., etc. Type Code Symbol Stamp ___ N_R _______ _ Authorization No. ______ 3_6 ______ _ Expiration Date_l_0_/_3_/_9_4 _________ _ 4. Identification of System Chemical Volume Control N .... c.. e (A-rs J..,. ANSI B31.1 1967 Ed. 5. (a) Applicable Construction Code ANSA B31. 7 1970 Addenda, ___ N_,_/_A ____ Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components ASME .. -Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or Nol Pipe Spool CVC-2902 UE&C N/A N/A N/A 1973 Replaced No HT # EUD 1993 Replacemen t No Pipe Spool --2-CVC-2910 UE&C N/A N/A N/A 1973 Replaced No HT # EUD 1983 Replacemen t No 7. Description of Work ___ M_o_d_i_* _f_i_e_d __ b_o_r_i_c __ a_c_i_d_p_u_m_p_s_u_c_t_i_*
- 8. Tests Conducted:
- Hydrostatic D Pneumatic D Nominal Operating Pressure System Inservice Test PressureA Test Temp. NOT ° F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is SY. in. x 11 in., (2) tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- *
- FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacemen!:conforms to the rules of the ASME Code, Section XI. repair or replacement Certificate of Authorization No. ____ 3_6 ___________
Expiration Date __ __::l::.O::..L../--'4'-'/--=:.9..::3:.._ _______ _ Signed '"" Owner or Owner's Designee, Title Date 9 -..J-9 '19 ?.3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Insurance Co. of MA. _________________________________ have inspected the components described in this Owner's Report during the period ___ ___ to ,June, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in acCQrdance with the requirements of the ASME Code, Section XI. By signing this certiticate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engg. Association _ __ ______ _ r Inspector's National Board, State, Province, and Endorsements Date __ ----'-9_-_J_o=-- ___ 19 9)
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date February 15, 1995 Name PO Box 236, Hancocks Bridge, NJ 08038 Sheet_!_ of_.__ __________
_ Address 2. Plant Salem Generating Station Unit# --=2=--------------- Name PO Box 236. Hancocks Bridge, NJ 08038 WO #930114178 CJP #PS93-013, 2EC-3148-l Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp Authorization No. __ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ___ __..N"""/"""'A.___ _____ _ Address 4. Identification of System Control Air 21 CA330 & 22CA330 Valve Nuclear Class II 5. (a) (b) Applicable Construction Code ASME III 19 _lL Edition, _fill_ Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 __ 6. Identification of Components Repaired or Replaced and Replacement Components
- 7. 8. Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) (21 CA330) Masoneilan NIA NIA 34142-6 NIA Replacement N Plug& Stem 38358-6 Assbly. (22CA330)
Masoneilan NIA NIA 34142-6 NIA Replacement N Plug& Stem 38358-6 Assbly. -* Description of Work Replaced plug and stem assembly. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other D Pressure NOP psi Test Temp. NOT OF System Inservice Test NOTE: Supplemental sheets in fonn of lists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) TI1is Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- FORM NIS-2 (Back) *
- 9. Remarks W0#9301141782EC-3148-l Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are conect and this of the ASME Code, Section XI Replacement conforms to the rules repair or replacement Type Code Symbol Stamp __ _...,_N"'/A,_.__
_____________________________ _ Certificate of Authorization No. Expiration Date Signed
- "' Owner or Owner's ii' Date :J. -l s-, 19 75-CERTIFCATE OF INSERVICE INSPECTION undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins&o. of MA have inspected the components described in this Owner's Report during the period 9-J4., £,* 3 to 2-J J,.. '1 <; , and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Factory Mutual Engr. Assn. National Board, State, Province, and Endorsements Date ----'-,2_--_!_7 __ 19 C/ 5
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I. Owner Public Service Electric & Gas Co. Date _ __._A-"lop,.._n...._*1.;:i;4.._.
,_19,:..,9""'5'---------- Name PO Box 236. Hancocks Bridge. NJ 08038 Address 2. Plant Salem Generating Station Unit# -=2=--------------- Name PO Box 236. Hancocks Bridge. NJ 08038 WO 940418179 CJP PS93-092 2EC-3 l 73 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed Name Type Code Symbol Stamp Authorization No. __ __...N.!!./,_,A=-------- PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date ____ _____ _ Address 4. Identification of System Containment Sprav. 21 CS6. 22CS6 Valves Nuclear Class II 5. (a) (b) Applicable Construction Code ANSI 831. 7 19 ....Q2__ Edition, NI A Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Component Manufacturer Serial No. Board Identification Built No. 21CS6 Valve Anchor ET471-l-l NIA NIA 1993 Darling 22CS6 Valve Anchor ET471-l-2 NIA NIA 1993 Darling 2CSS9A PSE&G NIA NIA NIA 1994 --Pipe Spool PSE&G 2-CS-P-3 NIA NIA 1994 Pipe Spool PSE&G 2CS-P-4 NIA NIA 1994 7. Description of Work Install containments.pray isolation valves and support. 8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0
- Other D Pressure-21Q_
psi Test Temp. 70.3 oF *Full flow test SAT as per the requirements of ASNJE XIIWC-5221 (d) Repaired, ASNJE Replaced, or Code Replacement Stamped (Yes or No) Replacement y Replacement y Replacement N Replacement N Replacement N NOTE: Supplemental sheets in form of!ists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded *at the top of this fonn. * (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
- *
- FORM NIS-2 (Back) 9. Remarks __
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules repatr or replacement Certificate of Authorization No. Expiration Date Signed
- Owner or Date ""r -y--CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected.
the components described in this Owner's Report during the period 3 -9 "/' to cf--C -9'rand state that to the best of my knowledge and belie( the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. Inspector's Signature Commissions if' .q---:U S .µI 13 .SI A/ Y-'f3 ( National Board, State, Province, and Endorsements Date '-/ / r; / I { --19 <f-6
- * * -. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Name PO Box 236. Hancocks Bridge NJ 08038 Address 2. Plant Salem Generating Station Name PO Box 236 Hancocks Bridge. NJ 08038 Address 3. Work Performed Name PO Box 236. Hancocks Bridge. NJ 08038 Address Date December 13 1994 Sheet_!_ of_,.__ _________
_ Unit# ___________ _ q3 CJ 60 ,:f /7 t./ WO 93068174::-CJP S93-236. DR SMD-93-268 d"" i/ Repair Organization P.O. No., Job No., etc. Type Code Symbol Stamp .o..:N,..,/A_._ _____ _ Authorization No. __ __._N..._IA._..... _____ _ Expiration Date ____
- 4. Identification of System Reactor Coolant 2PR1028 Spool Nuclear Class II 5. (a) (b) Applicable Construction Code ANSI B3 l. 7 19 _§.2._ Edition, _Q2__ Addenda, NI A Code Case Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) 2PR1028 Pullman NIA NIA NIA 1970 Replacement N ( I Spool to Power ' 2PR25 Valve -* 7. Description of Work __._R""'e'.&<p,..la=ced,.,._b..,o..,,l""'tin'"'lg,....
_______________________ _ 8. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure S
- Other ttJ Pressure NOP psi Test Temp. NOP OF System Inservice Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) lltis Fonn (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, N. Y. 10017
- 9. *
- FORMNIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement confonns to the rules of the ASME Code, Section XI repatr or replacement Certificate of Authorization No.
___________ Expiration Date __________ _ # /,,? / " Signed ,,_,./ Owner or Owner's Designee, Title Date I -) , 19 "ls-= CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersev and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owners Report during the period 2 -Y-f z" to , /t;,/7:.r---:and state that to the best of my knowledge and beliet:'the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the .requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and c2rrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. A _:;- / Inspector's Signature National Board, State, Province, and Endorsements Date ---"'/_-_..k ____ 19
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date March 27, 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _I_ of_...__ __________
_ Address 2. Plant Salem Generating Station Name Unit# _ _,2=--------------- PO Box 236, Hancocks Bridge. NJ 08038 WO #940224133 CJP PS94-009 2EC-3220 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by_..P_,.S=E=&=G"'"-------- Type Code Symbol Stamp .._.N""'"/A........_ _____ _ Name PO Box 236. Hancocks Bridge, NJ 08038 Address Authorization No. Expiration Date
- 4. Identification of System Reactor Coolant -2PS 1 Valve -Nuclear Class II WE-Spec 5. (a) Applicable Construction Code 676270 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components
- 7. 8. Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No . Replacement Stamped (Yes or No) Plug & Stern Copes Vulcan SN #93-5 NIA NIA NIA Replacement N Assembly Nuts (8) Viteo NDQ NIA HT #19260 NIA Replacement N Studs (8) Viteo NOP NIA HT #501315 NIA Replacement N --Description of Work Replaced valve entered with material ofnew design and replaced bolting. Tests Conducted:
Hydrostatic D Pneumatic D Nominal Operating Pressure D Other C8l Pressure NOP psi Test Temp. NOT of System Inservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, N.Y. 10017 ..
- FORM NIS-2 (Back) *
- 9. Remarks WO #940224123 2EC-3220 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules repair or replacement Certificate of Authorization No.
Expiration Date Signed ' Owner or Owner's Date Lf" -I .s ' 19 ., .r--CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period lo-11-fr' tot/-lf-'f f 7 , and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Ow11er's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthem1ore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. -=J:-=V'_(.=-. __ M_:.:f"-"--'3__,_V.._ ________ _ F fuSPector's Signature National Board, State, Province, and Endorsements Date _ __._0_-___./f"..._____ 19 ---------- -
- *
- FORM NIS-2 OWNER'S REPORT FOR REPAffiS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner Public Service Electric & Gas Co. Date March 27 1995 Name PO Box 236. Hancocks Bridge. NJ 08038 Sheet _l _of_.__ __________
_ Address 2. Plant Salem Generating Station Name Unit# PO Box 236. Hancocks Bridge. NJ 08038 WO #940224123 CJP PS94-010 2EC-3220 Address Repair Organization P.O. No., Job No., etc. 3. Work Performed by-=-P-=S=E=&""'G;.._ ______ _ Type Code Symbol Stamp ""'N""'IA...__ _____ _ Name Authorization No. __ __.N""'l"'"A..__ _____ _ PO Box 236. Hancocks Bridge. NJ 08038 Expiration Date Address 4. Identification of System Reactor Coolant -2PS3 Valve -Nuclear Class II WE-Spec 5. (a) Applicable Construction Code 676270 19 NIA Edition, NIA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 6. Identification of Components Repaired or Replaced and Replacement Components
- 7. 8. Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) Plug& Stem Copes Vulcan SN#93-6 NIA NIA NIA Replacement N Assembly Nuts (8) Viteo NDQ NIA HT #19360 NIA Replacement N Studs (7) Viteo NOP NIA HT#501315 NIA Replacement N --Studs (I I) Nova NIA NIA HT #24848 NIA Replacement N Description of Work Replaced valve internals with material of new design and replaced bolting. Tests Conducted:
Hyarostatic D Pneumatic D Nominal Operating Pressure D . Other t8I Pressure NOP psi Test Temp. NOT of System Inservice Test NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8 112 in. x l I in., (2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12182) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St, New York, N.Y. 10017
- FORM NIS-2 (Back) *
- 9. Remarks WO #940224127 2EC-3220 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, Section XI Replacement conforms to the rules repair or replacement Certificate of Authorization No. --'N'""/'"'"A_,_
__________ Expiration Date ___,N'-"-'/A_,_ __________ _ Signed .......... -/_"'""d-u"-=n...___ Date __ ___ , 19 Y ,f-Owner or Owner 1 s ' CERTIFCATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Arkwright Mutual Ins. Co. of MA have inspected the components described in this Owner's Report during the period / D-/ 7-9¥ to t/--, and state that to the best of my knowledge and belief: the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By Signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual Engr. Assn. --'n=i""-"'<....;..;....;; '=-* Commissions __ _______ _ Signature National Board, State, Province, and Endorsements Date __ 11_* .-_* /....::...."f_,_ 19 tf5"" FORM NR-1 REPORT OF REPAIR D MODIFICATION &(l OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l
- 1. Work performed by Public Service Electric & Gas Co. -Nuclear Dept * (name} CJP #PS93-008 (repair organization's P.O. no., Job. no.,etc.}
Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address) (name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address)
- 3. Name, address and identification of nuclear power plant Salem Nuclear Generating Station Unit #2 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System Reactor Coolant Nuclear Class I --5. a: Component repaired, modified or replaced 2PR.l Valve -------------------------------------
b: Name of manufacturer c: Identifying nos. 6918-95001-164-4 N/A N/A N/A (mfr's. serial no.) (Nat'l.Bd.No.) Uurisdictional no.) (other) d: Construction Code W E-Spec NIA ANSI B31. 7 1969 Ed:litiorl,970 Add. (addenda) (Code Case(s)) 6. Section XI 1986 N/A (edition) (addenda)
- 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 (edition)
B. Applicable edition of-Construction Code under which repairs. modifications, or replacements were made: *1969 1969 (year built) N/A (Code Class) N/A (Code Case(s)) N/A __ (addenda) (Code Case(s)) 1970 N/A (addenda) (Code Case(s)) *ANSI B31. 7 /W E-Spec E-676270 (edition)
- 9. Design responsibilities
---=PS'-=E=&G=-='-------,---------------------------------------
- 10. Tests conducted:
hydrostatic D pneumatic D design pressure O **pressure NOP psi Code Case(s) N/A *. Description of work Replaced cage, plug and stem assembly with* upgraded (use of add11ional sheet(s) or sketch( es) 1s acceptable 1f propedy 1dent1f:ed)
- 12. Remarks Desiqn Change Package #: 2EC-3190 Pkq. 1 Rev. N/A See attached pages for Description of Replacement.
N/A ** stem Inse.rvice Test . NOI' CERTIFICATE OF COMFLIANCE We certify that the statements made in this report are and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102. current edition. Certificate of Authorization no. 36 to use the "NR" stamp expires Oct. 3, , 1994 ----Date] *-;J o PSE&G Co.-Nuclear Dept. 19, o/ 3. Signed ________________ _ Principal Ergr. (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri: t Mutual Insurance Co of MA have inspected the repair, modification or replacement described in this report on l , 19 9 3 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National
- Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be le in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Date 7-Z 1 / Factory Mutual Ergr. Assn. , 18L_. t+vS.....c Commissions}.)/S'f'1'f f-<./I( A/::JJZ} (Inspector) (Natl.Bd.No.(including endorsements)s;ate or province and number) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbo*s; OH 43229. NB-s* H:ev f
FORM NR*1 REPORT OF REPAIR 0 MODIFICATION g] OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l *1. Work performed by Public Service Electric & Gas Co. -Nuclear Dept. (name) CJP #PS93-009 (repair organ;zation*s P.O. no .. job. no .. etc.) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address)
- 2. Owner Public Service Electric and Gas Co. l --------------------------------------------------(name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address)
- 3. Name, address and identification of nuclear power plant Salem Nuclear Generating station Unit #2 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System Reactor Coolant Nuclear Class I 5. a: Component repaired, modffiedorreplaced
______________________________ _ b: Name of manufacturer __ c: Identifying nos. 6910-95001-164-3 N/A N/A N/A 1969 (mfr's. serial no.) (Nat'l.Bd.No.) Uurisd1ctional no.) (other) (year built) d: Construction Code W E-Spec N/A I ANSI B31. 7 1969 Eru1iori970 Add. (addenda) (Code Case(s)) (Code Class) 6. Section XI 1986 N/A N/A (edition) (addenda) (Code Case(s)) 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 (edition) N/A __ _ (adcer.da) (Code Case(s)) 8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 N/A *ANSI B31. 7 !Tfl E-Spec E-676270(editionl (addenda) (Code Case(s)) 9. Design responsibilities
- 10. Tests conducted:
hydrostatic D pneumatic D design pre:,;ure O **pressure NOP psi Code Case(s)_-"-n/"-"-A-"-------- .1. Description of work Replaced cage, replaced valve bolting". plug arrl stern assembly with up:Jraded material and (use of add:t1ona! sheet(s) or 1s acceptabie if properly identified)
- 12. Remarks: ----'W'-"o>o<.r
.... k....__,Qrd"""'""""'er....__.#._.:'-----"9'""'3'"""'0'"""'1 .... 1 ... 2 .... ________ Desiqn Cllange Package #: 2EC-3190 Pkq. 1 Rev. N/A See attached pages for Description of Replacement. N/A ** stem Inse:rvice Test * :NO!' CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NR" stamp expires Oct. 3, , 19 94 ----Date 2 --' c PSE&G Co.-Nuclear Dept. 19,_u_. Signed _______________ _ Principal Engr. (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mutual il1§lrance Co of MA have inspected the repair, modification or replacement described in this report on -' 'J.. / , 19 f 2 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be le in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Dato 7-1'1 1//7 s;geod9c-vn.q./( {W-(Inspector) (Natl.Bd.No.(including endorsements)s!a!e or province and number) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) iB . TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l
- 1. Work performed
- Public service Electric & Gas CO. -Nuclear Dept
- CJP #PS93-0ll Rev.1 (ra".'ei (repa*r organization's P.O. no .. JOb. no .. etc.) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address) (name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address)
- 3. Name, address and identification of nuclear power plant salem Nuclear Generating Station Unit #2 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System Steam Generator Feedwater Nuclear Class II 5.a:
__ ____________________________ _ b: Name of manufacturer Pullman !?<:Mer Prcx:lucts c Identifying nos. N/A N/A N/A N/A ____ _ (mfr's. serial no.) (Nat'l.Bd.No.) (Jurisdictional no.) (other) d: Construction Code ANSI B31. l 1969 1970 N/A ANSI B31. l 1967 (edition) (addenda) (Code Case(s)) 6. Section XI 1986 N/A (edition) (addenda)
- 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 (ed.!,Oil)
- 8. Applicable edition of Construction Code under which repairs. modifications, or replacements were made: *1969 *ANSI B31. 7 /ANSI B31.1 1967 (edi!ion: (year built) II (Code Class) N/A (Code Case(s)) N/A
__ _ (Cooe Case's:; 1970 N/A (aodenda) (Code Case(s); 9. Design responsibilities -=PS==E=&G=-"-----------------------------------------
- 10. Tests conducted:
hydrostatic 0 pneumatic 0 design pressure 0 **pressure NOP psi Code ____ _ Description of work Replacec'i pipe spool. (use of aocirional snee::s; or si<e!c;-.(es}
- s accep
- abie if pro::>er!y 1oentif.ec, 12. Remarks: __ Wun ....
..... J_.J _________ __..De....,,,,._f ......... ic ..... i,_ency,.._.,,__ ..... R,,.er!po,.,..,.rt.........__:/f......_:_t{"'¥--/..._.A.__ _______ _ Design Change Package #: 2EC-3216 Rev. 01 See attached pages for Description of Replacement. N/A CERT!l=!CATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NR" stamp expires Oct. 3, , 19_9_4 __ _ Date C* -// PSE&G Co.-Nuclear Dept. 19,-23_ Signed ________________ _ Principal Engr. (a'JI!"'iorrzeo represen:a:,ve} (!it!e) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual Insurance Co of MA have inspected the repair, modification or replacement described in this report on -7 ) and that tc the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore. neither the Inspector nor his employer shall be le in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. . 9 .-( Factory Mutual En¥* Assn. Date 7-"l--, i9Ct J Signedr 0 ,,-z.,.,t/ £ * : .)___ Commissions A//;' 5'{CJ'f Jh'H )..:'SJ J J (Natl.Bd.Nc.(*"c'uding o* o*ov.nce and This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. FORM NR-1 REPORT OF REPAIR [J MODIFICATION L: OR INSTALLATION OF REPLACEMENT(S) zg TO NUCLEAR COMPONENTS AND SYSTEMS IN POWER PLANTS Page l of l . .1. Worl< performed by Public SeJ::vice Electric & Gas Co. -Nuclear Dept. (name) Foot of uuttonwcxxl Roa.d, Hancocks Bridge, NJ 08038 (address) (name) Foot of Buttonwcxxl Road, Hancocks Bridge, NJ 08038 (address)
- CJP #S93-045 (repair organ1za11on's P.O. no .. job. no.,e!c.)
- 3. Name, address and identification of nuclear power plant Salem Nuclear Generating Station Unit #2 Foot of Buttonwocxl Road, Hancocks Bridge, NJ 08038 4. System Main Stearn Nuclear Class II 5.a:
b: Name of m<Jnufacturer Rockwell International Inc. c: Identifying nos. WA729 N/A N/A N/A ____ _ senal no.) (Nat'l.Bd.No.) Uurisdic11onal no.) d: Construction Code ASME III 1971 872 6. Section XI (edition) 1986 (ea1tion) (addenda) N/A (adaenaa) (otner) 1year bud:) 1791 II (Code Case(s)) (Code Class) N/A (Code Case(s)) 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 S86 __ _ 1acderida) (Code Case:s*) 8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 N/A *ANSI B31. 7 :edit!on) (accenda) (Code Case(s)) 9. Design responsibilities PSE&G --------------------------------------------
- 10. Tests conducted:
hydrostatic pneumatic O design pressure O** pressure 1356 psi Code Case(s)_..::cN-"'/'--'A=--------
- 11. Description of work Replaced valve arrl piping in kirrl from folio. * (use of ada1t!onal shee::s) or
- s acceo
- ao*e 1' D'Doer'y :ae":1:1ed;
- 12. Remarks:
..__: Design Olanqe Package #: N/A Rev. N/A See attached pages for Description of Replacement. N/A **SVstern Inservice Test @ NOP, NOI' Temp. 84.5°F CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described abc*e conforms to Sect1cn Xl of the ASME Code and the National BDard rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NR" stamp expires Oct. 3, , 1'9_4 __ _ Date ) * ") c.' PSE&G Co. -Nuclear Dept. / / / 19,_f:,i___. Signed ______________ . LL* Principal En:Jr. (repair organization) (auu:onzed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwriqht Mutual Insurance Co of MA. have inspected the repair, modification or replacement described in this report on J -12 ' 19 er ...5 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the Natior.al Board rule*s as defined in the publica:ion NB-102. current edition. By signing this certificate. neither the Inspector nor his makes any warranty, expressed or implied, concerning. the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be *e in any manner for any personal injury or property damage or a less of any kind arising from or connected with this inspection 7 -/-Factory Mutual En:Jr. Assn. Date -).. J _. Signed \____ * '*:/ (
- g7i.f [N;l dfl I 1,-:s:)ec:or)
- Na:1.Bd or arc _ -:);;*) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81
/ FUlt\I J ,\li\,\lWi\CTl!Hl*:us* IJ.\T,\ 111-:l'IJllT HJll 011
Rockwell International I. a.tanufaccured hy. P.O.
__ No __ 6_1_-_3_8_8_2_3 __ _ (Name* Addr*** or M&nuloc1ur*r' Public Service.Electric and Gas Co. El60053.*
- 2. *Manufaccurcd for 80 Park
_____ Order No. __ C_H_G_._N_o_._l_G __ (Nam* and
- 3. Owner Public Service Salem Nuclear Generating Station, Units l and 2 4. Locadon of Planr Lower Alloways Creek ToW?lship, Salem County, New Jersey 5. Pump:irValvefdcnciCicuion (10) 2"838YT2 Check Valves Serial No's. l*?J\726 Thru NJ\735 Rockwell International Lot No
- Hl514 . (Briel de*crlptlon o( o.rvlc* (or whlct. *qulpm*r\I wu dulcn*dJ (a) Drawing No, 3160514 3 Rev. NonePrep:ircd by:* ___ D_a_v_i_d_H_._T_h_e_r_n_e_a_u
_________ _ (b) National Board No. _N_o_n_e ____ _ 940 700 6. Deaip Condidons
psi-------
°F ( T eU1pe ral ur*). (Pru1ure) 2 tta* *The mac.erial, design, conscruciion, complies '1dth Code Sccrion Ill. Class * *. Edicion 1971 * , Addenda June 30,1972 , C:i* .. "ln. _____ 1_7_9_1 _________ _ -Mark Ho, Material Sp*c, No, Manufac1uru (*) Casdn&s NA -.. **:** -... --... ----(b) Foridns:s Valve Bodies BM954N SJ\105 Texas Forge Republic Heat 60161 : .. * .. . \ Valve Covers BM931N SAlOS Texas Forge Republic Heat 54467 -Valve Covers BM452N SAlOS Texas Forge Armco Heat 63U74 ... -. *llupPl*mrnl*I
- h*rll In (orm o( llalo, 1krlch*a <'* drawlnK* ni*y br uaro.1 provlo.lril (I) ohr 11 8\i" a II", (l) ln(ormallon In II*"'"* 1*. 2, Sa end lb on I.hi* dml* uporr 11 lncluJrd on rach 1hrr1, and (J) eub ahut I*
11nd of *hrel* I* ,..corded
- t top orthla lot.. -;: *,* :. . ... ** :: 1 * : *. . .. . : .. , # ** 65 11 : .. ,.
- \'
- ..
- , .. *. ' ::: .. 1257 ... '. tc) (d) Dolt Valve Valve . Orher Paris lduk No.
F-KS Caoscrews F25 FOll\l ,\l'\'-1 {Lud..) Mot*rl*l No, M*nwf*tll**t Rrm*rkl SJ\193 GP.B7 Te;XuS P.olt Peoublic flea t P.8973 SJ\193 GRB7 TcY.as Bolt Reouhlic Heat 60638 . Valve Disks Fl816 SJ\182 GRFll Coulter Timken Heat 84380 . . . 2175 8, Hydrosracic psi. CERTIFICATION OF Design informarion on file ar Rockwell International, _______ _ Scress :in:ilysis report on rile ac Rockwell International, Sulohur Springs, Texas Design specHicarions cerriricd by Edward J
- Siegel (I) Pro(. En!!. Sure N
- J
- Reg. No.10-41Q Srress an:alysis report ceni(ied by David H. Therneau (I) Pror.Eng.Stalc...:To.:X:..;;_
__ (1) Signature noc required. Lise name only. We c:ertHy chat rhe Sta!emenrs made in this report are correc1, *Dace j.,,efU"rl,, 19 7r Signed Rockwell International V-/ I (M*no.Jocturrr) / 7 CerrHicace or Aurhorizacion No. __ N_-_1_8_1_4 ___ expires August 12, 1980 CF.nTIFICATE OF SllOP I, the undersignec, a valid commission issued by the National Board or Doilcr and Pressure Vessel Inspectors and/or lhe St:ire or Pro,*ince or Texas :ind by Lumbcrmens Mutual Casualty Co of Long Grove' IL 60049 have in spec led rhe equipm<.'nt described in this D:ua Report on / -{z and sr:ite 1h:1t [0 the best or my knowledge
- 1nJ belid, the !.l:inuracrurer has c:onstrucrc:d this equipment in accocd:ince wirh the :iprlic:ible Subsectillns or CoJc, Section Ill. By signing this cerrHic:irc, neirhcr c!ie Inspector nor his emplurer m:il.:cs :iny "*arr:mty, expressed or implicJ, concern* ing the equipme:u describcJ in this O:it:i Report. fourrhermore, neither rhc lnsrt*ccor nor his e:nplo)'..:r sh:ill be li.:ib!c in :any m&Mer for any person:il injury or property J:im:ige or a loss of :my kind arising from or connecreJ with this inspection,
__ 19 ZcE J- .... .. , .. Prlnled In U.S.A. (6/72) Thlo '""" (EJ7) I* o!Aaln*blr frorn th* ASl.41!:, 345 E. 47th St., N** Y9i'k, N,Y. IOOU' ... . .
- . * M:Jr. J "* * '
.. . .-*. * ** . .. ***r,;****.:.:-**** FORM NR-1 REPORT OF REPAIR = MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) X: TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l .1. Work performed
- Public Service Electric & Gas Co. -Nuclear Dept. CJP #S93-120 Rev. 1 (r.arne) :reoa-r o*gan1zat1on"s P 0. no .. )Ob no .. elc.) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address)
Public Service Electric and Gas Co. (name) Foot of Buttonwcxx:l Road, Hancocks Bridge, NJ 08038 (address)
- 3. Name, address and identification of nuclear power plant ___
__ Nu_c_l_ear __ Genera ____ t_mg_' ___..,__S_ta_t_i_o_n __ _______ _ Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System Reactor Coolant Nuclear Class I 5. a: Component repaired, modified or replaced 2PR5 Valve --=------------------------------------- b: Name of manufacturer Crosby Valve & Gage Co. c: Identifying nos. RV-2-8010B N/A N/A N/A 1986 (Nat'l.Bd.No.) Uurisdicuonal no.) (other) (year built) d: Construction Code _6=-7-=-=6=2'-'7-=9'------ N/A N/A I ANSI B31. 7 1969 &krioQ\.970 Add. (addenda) (Cade Case(s)) (Code Class) 6. Section XI 1986 N/A N/A (eaition) (addenda) (Code Case(s)) 7. Applicable edition of ASME Code Section XI under which repairs, moc:ficatiors, or replacements were made: 1986 N/A __ (ec:!*o::) (adder.da) (Code Case1s;: 8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 N/A *ANSI B31. 7/Yl E-Spec. 676279 (addenda) (Code Case(s)) 9. Design responsibilities PSE&G
- 10. Tests conducted:
hydrostatic D pneumatic D design pressure O **pressure NOP psi Code Case(s) __ N_/'"-A ______ _
- Description of work Replaced fla!"9e bolting * (use of add111onai snee!(s) or sketcn(es) 1s acceptable i( prooeny 1ce'lt1(1ec)
- 12. Remarks: __
Desiqn Cllange Package #: N/A Rev. N/A SMD 93-256 See attached pages for Description of Replacerrent. N/A **SVstem Inservice Test Temp. N/A CERTIFICATE OF COMPLIANCE We certify that the statements made ifl this report are correct and the repair. modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "N R" stamp expires oct
- 3, , 19 94 ----Date ') -( PSE&G Co.-Nuclear Dept.
Signed _______________ _ Principal En¥* (repair organization) (authorized represe11tat1ve) (ti!le) CERTIFICATE OF INSPECTION I, the undersigned. holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors. and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mutual Insurance Co of MA have inspected the repair. modification or replacement described in this report on 5--;:...; , 19/ .5 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty .
- ssed or implied, concerning the repair. modification or replacement described in this report. Furthermore.
neither the Inspector nor his employer shall be in any manner for any personal injur(2or roperty damage or a loss of any kind arising from or connected with this inspection . . ** .* /' Facto:;Y Mutµal Engr. Assn. Date '7 /f . 1 r.l_. Signed { ' Commissions/JP Jt/i 'I 'Vv 1/r' A./J} l j ;' (lnspec:or) {Natl.Bd.No.iinciud r.g erco,se-ne,-,:s:s:a:e or prowxe This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. FORM NR*1 REPORT OF REPAIR Kl MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S)
- J TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l
- 1. Work pertormed by _ _,,Pub=-=::..:l::..:l::..:
0 c=--=Serv==-.:..cl=* -..:1=---':namej [reoair organ:zat1on's P 0 .. 10 .. jOO. .. etc.: Foot of Buttonwcai Road, Hancocks Bridge, NJ 08038 (adcress) 2.0wner __ Pub __ l_i_c_Serv __ 1_'ce __ __ Gas __ Co __
- _________________________
_ (name) Foot of ruttonwood Road, Hancocks Bridge, NJ 08038 (address)
- 3. Name, address and identification of nuclear power plant Salem Nuclear Generating Station Unit #2 Foot of ruttonwood Road, Hancocks Bridge, NJ 08038 4. System <llemical Voluroo Control Nuclear Class II 5.a:
b: Name of manufacturer Copes Vulcan c: Identifying nos. 7410-95269-1-2 N/A N/A N/A ---=1=9'--'7--=6'------(mfr's. serial no.) (Nat'l.Bd.No.) Uurisd1ctional no.) (othe') d: Construction Code ASME DP&V 1968 1970 N/A ANSI B31. 7 1969 Edi.!ionl970 Add. (addenda) (Code Case(s)) 6. Section XI 1986 N/A (edition) (addenda)
- 7. Applicable edition of ASME Code Section XI under which repairs. modifications.
or replacements were 1986 (e<i:t1on)
- 8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1968 *ASME P&V/ANSI B31. 7 1969 E::l. 1970 Add. (edition) (year built) II (Code Class) N/A (Code Case(s)) N/A _N_,_/A __ _ (addenda) (Code Case(s)) 1970 N/A (addenda) (Code Case(s)) 9. Design responsibilities
--=PS===E:.::&G=-=------------------------------------------
- 10. Tests conducted:
hydrostatic D pneumatic 0 design pressure O **pressure NOP psi Code Case(s) __ _____ _ .1. Description of work Perfonned weld repair to valve leak off line. (use of add1t1ona1 sheet(s) or 1s acceptaole 1f prooerly 1dentif:ed)
- 12. Remarks: __
Design Qlange Package #: N/A Rev. N/A Rev. 1 see attached pages for Description of Replacement. N/A ** stem Insel:Vice Test
- NOl' CERTIFICATE OF COMPLIANCE We certify that the statements made-in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NR" stamp expires Oct. 3 1 , 19_9_4 __ _ Date 2 * -:J-r 19,_ti._.
Signed. __ PS_E_&G_eo_._-_Nu_c_l_ear __ Dep_t_. __ .-Principal ElW. (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION I, the holding a valid commission issuoo by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual Insurance Co of MA have inspected the repair, modification or replacement described in this report on and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate. neither the Inspector nor his employer makes any warranty, ressoo or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be le in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 7/, / / / . Facto:r-y: Assn. Date t->'f , vff 3 . Signed/(.
- Commissions
&81rtf 1['1h1 /Ufj 73 (Inspector) (Natl.Bd .No.( including endorsements)state or province and number) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. FORM NR*1 REPORT OF '1EPAIR C MODIFICATION= OR INSTALLATION OF REPLACEMENT(S) TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l 1 Work. performed c , Public Service Electric & Gas Co. -Nuclear Dept. GJP #S93-129
- Foot of Buttonwoo:l Road, Hancocks Bridge, ID 08038 .--, I 1aac*ess; 2 Owner Public Service Electric an:i Gas Co. fnar.ie; Foot of Buttonwocxi Road, Hancocks __ 0_8_0_J_8
__________
- 3. Name. address and identif1cat1on of nuclear power plant Foot of .Buttonwocd Road, Hancocks 4. System canponent Cooli.JB 1address1 Salem Nuclear Generati.nq Station Unit #2 Bridge, ID 08038 Nuclear Class II b: Name of manufacturer Anchor Darl@ .,/ c: Identifying nos ____J,_:;3_934 7 N/A N/A N/A 1987 cmt. '* ser;al no.; (Nar;.Bd.No.) (Junsd1ct1ona:
no.; (Otner) {year :>u11t* d: Construction Code ASME III 1983 Winter 1984 _______ N_/_A ____ _ II ANSI B31. 7 1969 F.d1.worl970 Add. :addenda) (Code Case(s)} (Code c:assJ 6. Section XI 1986 __ ...,N"-/""A.__ ___________ _ N/A (ecn1on) 1aodenda) (Cooe Case1s;1 7 Applicable edition of ASME Code Section XI under which reoarrs. modifications. or replacements were made* 1986 N/A N/A (ed1t:on1 fadoendal (Coae Case1s;. B. Applicable edition of Construction Code under which repairs, modifications. or replacements were made* *1983 W83 N/A *ASME III/ANSI B31. 7 1969 Ed. 1970 Add. (ed111on1 (adaenaal (Code Casers11 9. Design responsibilities _PSE=--.:.=-&G--'-----------------------------------------
- 10. Tests conducted:
hydrostatic 0 pneumatic O design pressure D **pressure NOP psi Code Case(s)_--=N"-'/c...:A=------- 11 Description of work Replaced vhl ve bol ti.n;J. (use of aadr::onai shee7:s) or Sl{etcrites; is acceo;a::He 1i orooeny *aenti!.ed;
- 12. Remarks* _
________ ___ _ Qlarge Package #: N/A Rev. N/A See attached pages for Description of Replacerrent. N/A ** stern Inservice Test . NOT CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair. modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition Certificate of Authorization no --36 to use the "NR" stamp expires Oct. 3 / . 19 94 ----PSE&G co.-Nuclear Dept. Date 2 -.5 ( 19,--2:,,.f_ Signed _______________ _ Principal ID;µ". (repair organization) (autho* !ed represen:a:.ve) (t11te} CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors. and certificate of competency issued by the state or province of Ne'w\7 Jersey and employed by Arkwri t Mutual Co of MA have inspected the repair, modification or replacement described in this report on , 19 f J and state that to the best C'f my knowledge and belief. this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty: or implied. concerning the repair. modification or replacement described in this report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or or a loss of any kind arising from or connected with this inspection. Factory Mutual Erg!". Assn. te /.. /.1 J7 , 10;J.._. Signed *]1 Sb Commissions f./ /3 b .3 _,.( L J..h S lf.)J -r3 / f (Inspector) (Natl.Bd.No.(1nclud1ng endorsements)state or province and number) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229.
- FORM NR-1 REPORT OF REPAIR CJ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S))Z TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Pa e l of l 1.Workoertormedby
.......... _____ _ (narT"e) (repair organizat1on*s P.O. no .. JOb. no .. erc.) Foot of 8.:rttonwood Rood, Hancocks Bridge, NJ 08038 (address) (name) Foot of Buttonwocx:l Road, Hanccx::ks Bridge. NJ 08038 (address)
- 3. Name, address and identification of nuclear power plant Salem Nuclear Generating Station Unit #2 Foot of l3utt,oowood Road, Hancocks Bridge. NJ 08038 4. System Olexnjral
& Voluma Qmtrol Nuclear Class I 5.a: b: Name of manufacturer __ ... sa""""ne._,..._.j_.J_..a .... n..__ __________________________________ _ c: Identifying nos. H2060301 N,IA (Nat'l.Bd.No.) d: Construction Code E-Spec 676270 6. Section XI (edition) 1986 NIA J Ourisdictional no.) NIA J (addenda) (edition) (addenda) (other) NIA J NIA J (Code Case(s))
- 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 (edition)
- 8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *N/A *Westinghouse E-Spec. 676270 (edition) 1987 (year built) (Code Class) N/A (Code Case(s)) N/A =N/<-=A.:.._
__ (addenda) (Code Case(s)) N/A N/A (addenda) (Code Case(s)) 9. Design responsibilities
- 10. Tests conducted:
hydrostatic O pneumatic O design pressure O **pressure N/A psi Code
- 11. Description of work Valve stem arrl plug Were replace'.i in kin:i. (LlSe of adait;onal sMe!(s) or sketch( es) is acceptable 11 properly identJlied)
Ref.: PSE&G E-Requjsjtion No. E0630546 an;j E0630547 12.Remarks: ....... .......... ......... ......... ........ J)?.sign Change Package #: N/A Rev. N/A See attached pages for Description of Replacerrent. N/A **Inservice SVstem Test Telnp. NOI'/NOP CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NA" stamp expires Oct. 3, , 19_9_4 __ _ PSE&G Co. -Nuclear Dept. / / Date Iv-2-') 19,_.f_.i._. Signed ______________ .>444'4. L.'. 4
- Principal Er'Br* (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION
_I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mutual Insurance Co of MA have inspected the repair, modification or replacement in this report on /c,--1) , state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be .e in any manner for any personal or property damage; a of any kind arising from or connected Engr
- Assn. Date iO**ZG, , 1&._. Signe ,/ {' Commission!¥\/ifff'{
U;-J N:J721 (inspector) (Natl.Bd.No.(including endorsements)state or province and number) This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6 FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Pa e 1 of 1 .1.Workperlormedby .......... _____ (name) (repair organization's P.O. no., job. no.,e!c.) Foot of Bllttonwcxx'l Road, Hancnc:ks Bridge, NI 08038 (address) (name) Foot of Bllttonwood Road_. Hanc.ocks Bridge, MI 08038 (address)
- 3. Name, address and identification of nuclear power plant __ _.S""a.._..l.s;:eoum.L-LN!......,JC
... l....,e .. .. '"'n...,e ...... ra......,.t ... ... :a...,t_1....,' o..,n......____.I .... rn ..... 1.._' t...._.Jl#'-"2.__ ______ _ Foot of Bnttonwood Rood, Haru:xr.ks Bridge, NI 08038 4. System Send ce water Nllclear Class II 5. a: Component repaired, modified or replaced _"S,..,Ta ....... l...,-.,f_..p...._.2""3 .... SW5 .............. 8,__ ____________________________ _ b: Name of manufacturer Masoneilan inte:rna.tional Inc c: Identifying nos. N-00203-1-8 N/A N/A (mfr's. serial no.) (Narl.Bd.No.) Qurisdictional no.) d: Construction Code Draft P&V 1968 (edition) (addenda)
- 6. Section XI 1986 (edition) (addenda)
N/A (other) WA (Code Case(s)) 1978 (year built) (Code Class) NIA (Code Case(s)) N/A N/A 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 (edition) (addenda) (Code Case(s)) Ml?D N/A 8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *ASME Draft Plm1p & Valve *1968 (edition) (addenda) (Code Case(s)) 9. responsibilities
- 10. Tests conducted:
hydrostatic O pneumatic O design pressure O **pressure N/A psi Code Case(s} _ _____ _ *Descriptionofwork The valve was replaced in kjnd (use of additional shee!(s) or sketch( es) is acceptable if properly identified) 12.Remarks: ___ .__,..._.._.. ...... ...... ....... _______ _ N/A ** CERTIFICATE OF COMPLIANCE We certify that the statements made in--this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NR" stamp expires Oct. 3, , I PSE&G Co.-Nuclear Dept. tJ P' / ., Principal Engr. Date /-23 Signed _______________ (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION _I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by
- ce Co of MA have inspected the repair, modification or replacement described in this report on , 19f3 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, *ssed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. . r / ,; Factocy Mutual. Assn. Date / /-l j , 19 Cf J . Signed ,.,.,rUJJ
('..
- Commissions AJJ 5f1 { fN /I /l/CJ ? 7) (Inspector) (Natl.Bd.No.(inciuding endorsements)state or province and number) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. '*
FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l .1. Work performed by __ (name) (repa1r organization's P.O. no .. job. no .. etc.) Foot of Buttonwcxx:l Road, Hancocks Bridge, NJ 08038 (address) Public Sei:vice Electric and Gas Co. (name) Foot of Buttonwcxx:l Road, Hancocks Bridge, NJ 08038 (address)
- 3. Name, address and identification of nuclear power plant Salem Nuclear Generatin;J Station Unit #2 Foot of Buttonwocx:l Road, Hancocks Bridge, NJ 08038 4. System Service Water Nuclear Class II 5. a: Component repaired, modified or replaced Butterfly Valve 23SW58 b: Name of manufacturer Masoneilan International Inc. c: Identifying nos. N-00203-1-8 N/A N/A (mfr's. serial no.) (Na!'l.Bd.No.) (jurisdictional no.) d: Construction Code ASME Draft P&V
__ 6. Section XI (edition) 1986 (addenda) N/A (edition) (addenda) N/A (other) N/A (Code Case(s)) 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 (edition)
- 8. Applicable edition of Construction Code under which repairs, modifications.
or replacements were made: *ASME Draft P&V *1968 (edition) 1978 (year built) II (Code Class) N/A (Code Case(s)) N/A __ _ (addenda) (Code Case(s)) M/70 N/A (addenda) (Code Case(s)) 9. Design responsibilities PSE&G --------------------------------------------
- 10. Tests conducted:
hydrostatic D pneumatic D design pressure D **pressure N/A psi Code Case(s) __ N=.cL-/-=-A-=----------
- Description of work The valve -vane taper pins were replaced in kind and seal welded (use of additional shaet(s) or sketcn(es) is acceptable if properly identified) in lace. 12. Remarks:
...... Design Oiange Package #: N/A
Reference:
CJP S93-279 See attached pages for Description of Replacement. N/A **NA
- NA CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NA" stamp expires Oct. 3, --, -19.94 ----Date I -..3 PSE&G Co.-Nuclear I:Ept.
Signed _______________ _ Principal Engr. (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mutual Insurance Co of MA have inspected the repair, modification or replacement described in this report on 2 i UEC. , 19 q .-3, and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty,
- sed or implied, concerning the repair, modification or re lacement described in this report. Furthermore, neither the Inspector nor his employer shall be in any manner for any personal injur er!}' age or I of a kind arising from or connected with this inspection.
_ Mutual Engr. Assn. Date 4 Jfr.;V, Signed Commissions r1r26o 7 ..:r A/ A ;<-/.:::T/O 2C) (Natl.Bd.No.(including endorsements)state or province and number) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) W TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTSpage l of l *. Work performed by Public *service Electric & Gas Co. -Nu::lear Cept. (name) Foot of Buttonwocx:l Road, Hancocks Bridge, NJ 08038 (address)
- 2. Owner Public Sei:vice Electric and Gas Co. (name) Foot of Buttonwocx:l Road, Hancocks Bridge, NJ 08038 (address)
CJP #S94-009 (repair organizat1on*s P.O. no .. ;oo. no.,etc.:
- 3. Name, address and identification of nuclear power plant Salem Nuclear Generating Station Unit #2 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System Chemical & Volume control Nuclear Class II 5. a: Component repaired, modified or replaced2CV166 b: Name of manufacturer I'IT Grinnell c: Identifying nos. SD-C-112277 N/A N/A N/A (mfr's. serial no.) (Nat'l.Bd.No.)
Qurisdictional no.) d: Construction Code ANSI B31. 7 1986 1970
- 6. Section XI (edition) 1986 (addenda)
NA (edition) (addenda) (other) (year built) N/A II (Code Case(s)) (Code Class) N/A (Code Case(s)) 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 (edition)
- 8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1986 N/A
__ _ (addenda) 1970 (Code Case(s)) N/A *ANSI B31. 7 (edition) (addenda) (Code Case(s)) 9. Design responsibilities PSE&G
- 10. Tests conducted:
hydrostatic O pneumatic O design pressure CT* pressure N/A psi Code _______ _ 11. Description of work Replaced valve l:xmnet in kind . * (use of additional sheet(s) or sketch( es) is acceptable 11 properly identified)
- 12. Remarks: Work Order #: 940201098 Ceficiency Retprt #: N/A Design Change Package #: N/A Rev. N/A See attached pages for Description of Replacement.
N/A **System Inservice Leak Test Temp. NOP/Nor CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NA" stamp expires Oct. 3, , ----Date L -? .a* PSE&G co. -Nuclear Cept. 19,-1'.i:::_. Signed _______________ _ Principal Engr . (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION I, the undersigned. holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mutual Insurance Co of MA have inspected the repair, modification or replacement described in this report on 2 , 19 Cf C/ and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be *. in any manner for any personal injury or Qroperty damage or a loss of any kind arising from or connected with this inspection. . _ * . / Fagory Mutual Engr. Assn. Date 2 -Y , 19 . Signed \___;__tyWJ/ (. Li-vL ---Commissionsf.({fftlt;fAJ/I A)cf}'?J ( (Inspector) (Natl.Bd.No.(including endorsernents)state or province and number) This form m.aY be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB*' R' 0 ------------ ---FROM: ITT Engineered Valves TO: 33 Ccnecrville Road Pennsylvania 17603 Public Service Electric & Gas Co Quality Assurance Oepartrnent AO Park Place Newark. 07101 377746 CERTIFICAT;; OF COMPt.I.ANCE Of s 9'(-* 00 1 PART TIME; 2 11 Bonnet *\eeQmbl1ss F.O.Item 001 f!l$UG P.O. NO.; P2-377746 w/Change Order Ol 047.3887 Cl/Code Number 40/476S SUPFlUEA ICfiNT. NO,; SIL-59601-1-l th:-u 7 QIJANTITY: Seven [7] sr:z.a: 2" SUPPUEO TO ll'USLJC SE1MC! ANO G..i.S COMPANY AS SPEClFIECI ON TJ.llE ASOVe A£FiiAEiNCiQ P\,IAc;HAliE OAC!in WAS PROC:!SS!C IN C:0MPUANC' WITH T'Hli FQLJ.QWING ,l'l!QUIAEMeNTS: 1986 Edition A8.S Addenda ASME B & PY Cgde Sestion III qnd =he IP<CSi"TION TO ACCmONAI.. AEOUIR!Ml!NTS _ _________________ _ OTHER SP£CIAL FFIOCS!SSES IWl!LOING. BAAZlNG. He.AT ETC.l NOT AEFeA&;NCEO AllOV! NA e REPAIR ACTIVrty HAS Bl;liN f'eRF011MlfC NO
- OATE NOTI:; INST!=!lJCTlCN COMPLETION OF c:RCt.EO NUMSER ARE.AS SX.AMeLES Aeveris1 9101.
- tTT ENGINEERED VALVES 33 CENTERVILLE ROAD LANCASTER, PA 17603 DIAPHRAGM VALVE CERTIFICATION .MI£ REPORT CUSTOMER:
Public Service Electric & OUR ORDER NO.: Gas Company-SALEM Generating Station CUSTOMER ORDER NO: P2-377746 w/Chanqe VALVE SIZE: 2"* ITEM: l Order 01 *Bonnet Assemblies only END PREPAAAT!ON -SOCKETWELD BUTTWELD F/SCH ---FLANGED SCREW];:O BONNET MATERIAL DUCTILE IRON: CARBON STEEL: -STAINLESS STEEL* ASME SA351 CFS TOPWORKS: Handwheel Operated TOPWORKS COVER MATERIAL: NA QUANTITY: 7 CLASS: TAG: P,O.!tem Number 001 CL/CODE Number 40/4765 BODY MATERIAL STAINLESS STEEL; CARBON STEEL; ALUMINUM: BONNET BOLTING MATERIAL 3
- ACCESSORIES:
V Notch Vent Plug "C" !Ung Sealed Travel Stop NUTS: NA
- DIAPHRAGM:
GRADE Ml EPDM TEST DATA BODY/WATER BONNET/WATER P.S.I. ACTUATOR REQUIREMENTS BONNET ASSY./AIR SEAT/AIR ACTUF\TOR/AIR ACCEPTANCE CRlTERIA: NA 450 ao NA NA NA NA 10 NA NA 30 NA NA NA NA NO VISIBLE LEAKAGE ALLOWED, BODY .PT MT SPEC, NA AIR TO OPEN P.S.I. AIR TO CLOSE P.S.I, LINE PRESSURE P,S.I. SPRING/S NO. BONNET BODY RADIOGRAPHY NA BONNET RADIOGRAPHY--- PAINTlNG: Standard Shop Primer Provisions of l0CFR21 apply to this order, NA NA NA ALL ITEMS DESCRIBED ABOVE WERE MANUFACTURED AND SUPPLIED ACCORDING TO THE REQUIREMENTS OF THE PURCHASE ORDER, AND PACKING PER WF-101-10-6
- 1 2 3 4 5 6 7 a 9 10 1 l 12 13 14 15 1e 17 18 20 ... 1 22 ITT Engineered Valves D9.1A Rev. o 7/16/86 Date: NUCLEAR CODE . Signed; cZ .<fl.
3 Plant .. Lancaster) .. PA .......... . Plant Job No. l-5.960 l ... 11em .. 1 .. The tollow1ng neat code numbers apply to the valv11s llste<l Diiiow;
Description:
2" Handwheel Operated Oiaphragm Valve t Assemolies w/Travel S t:Qpa . NA . . . . Sonnet DVC-100515. Rev Rl Ball , . Drawing No. & Rev. Body Material Soec .. Sooy . Material Spec., Studs Heal Nos. Studs NB# NA NA NA NA N'A NA llStl> Cover/ CFS .,A Bonner ASME SA35 l Crade . Sall N.A . Nuts NA . capscrews NA Nuts NA . Caoscrews . . Salls NA . Senal No. No. Body Cover/ eonnot l'ol) * .J.l.o;11< "'IUUaS: VVl 91-59601-1-1 CL/Code Number 40/476 1 7166-63 P.O.Icem 001 91-59601-1-2 Numher 40/4765 NA 7166-34 Number 001 91-59601-1-3 CL/Code Number 40/476i BL088W-5 P.O.Icem 001 91-59601-1-4 CL/Code N11mber NA BL515 -3 Number 001 'll-SQP,nl-l-li r.r /l".,-,t'lc. b.(l //.,, N'A -7 OOL 91-59h(l1-1-i:. r'T /r'.nrtc Nt,ft'll-.a.,. ti..n/&.7P,t NA 71A6-26 P.O. Item 001 "If VAiV5 2 e, V/66 91-59601-1 .. 7 CL/Code Number 40/476c NA 7166-40 ON -\ '. . FORM NR*1 REPORT OF REPAIR 0 OR INSTALLATION OF REPLACEMENT{S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of 5
- 1. Work performed by Public Service Electric & Gas Co. -Nuclear Dept. GIP #PS93-007 (name) (repa.* :i*:; ... 1,zat1on's P.O. no. JDb no .. e:c
- Foot of Buttonwocxi Road, Hancocks Bridge, lU 08038 (address) (name) Foot of Buttonwocxi Road, Hancocks Bridge, lU 08038 (address)
- 3. Name. address and identification of nuclear power plant salem Nuclear Generating Station Unit #2 Foot of Buttonwocxi Road, Hancocks Bridge, lU 08038 4. System Reactor Coolant Nuclear Class II 5.a:
__ __ A_tta __ __________ _ b: Name of manufacturer c: Identifying nos. __,,N"'/'-'A...,.__ ___ _ N/A N/A (mfr's. serial no.) (Na!'l.Bd.No.) no.) d: Construction Code PS Spec 69-6445 N/A 6. Section XI (edition) 1986 (addenda; N/A (edition) (addenoa) N/A (other) N/A (Code Case(s)) 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1986 (ed t1on1 8. Applicable edition of Construction Code under wh,.;f-1 repairs, modifications, or replacements were made: *PS Spec S-C-MBOO-MCS-043
- N/A (edr::o:-.:
1977 (yea* ::uit) II (Code Class: N/A rCode Case(s)) N/A _N_,_/A __ _ (addenda) (Code Casers ... N/A N/A (adder.da) (Code Case1s:; 9. Design responsibilities _PS_E_&G ________________________________________ _ 10. Tests conducted: hydrostatic O pneumatic C design pressLJre O **oressure N/A psi Code Case(s) __ _____ _ Mcxlified pressurizer pip@ supports .
- 1. Description of work (use of aoo1::o*a sneet(SJ or s<etc:-*esJ
- s accep:ao!e 11 oroper*y *oen:1'.:ec;
- 12. Remarks Work Order #: 930112144
- N/A Design C11ange Package #: 2EC-3190 See attached pages for Description
- CERTIFICATE OF COMPLIANCE We certify that the statements in this repcrt are correct and the repair. modification or *eplacement ot the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, currer:: 9dition. Certificate of Authorization no. 36 to use the "NR" stamp expires Oct. 3 1 , 19_9_4 __ _ PSE&G Co. -Nuclear Dept. # / Date ? -/ t 19,__LJ__.
Signed ________________ .& * '44 Principal Engr. (repair organizatior. (authorized representative) (mle) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued bf the state or province of New Jersey and employed by Arkwright Mutual Insurance Co of MA have inspected the repair. modification or replacement described in this report on t.(. z_q . 19 9 !z and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be ble in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 4 /} / Fa_9tory Mutual Engr. Assn. Date {-l.S .1&. Signed \J!YnuJ/ 1,. Commissions IJ/J)8't./'-/ VA /J,L? 2) / (Inspector) (Natl.Bd.No.(incluc "g endorsements)state or province and This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. Page _A_ of _,2_ FORM NR-1 ATTACHMENT Code Job Package No.: PS93-007 Work performed by: Public Service Electric & Gas Co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 2. Owner: Public Service Electric &*Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 3. Location: Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System: Reactor Coolant Nuclear Class:
==================================================================
ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: ---Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: 2C-PRLS-403 Name of Manufacturer: PSE&G N /A N/A N/A N/A 1993 No __________ _ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: PS Spec S-C-MBOO-Edition Addenda, Code Class II Code Cases:N/A MDS-043 ============================================================================== Name of Manufacturer:
- ID of Component Replaced:
Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: ---Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: 2C-PRLS-404 N am e of Manufacturer: __________________________ _ N/A N/A * /A N/A__ 1993 Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: PS Spec S-C-MBOO-Edition n/A_ Addenda, Code Class II Code Cases:N/A ___ _ ============================================================================== ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: __ _ Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: 2C-PRG-2434 Name of Manufacturer: N/A N/A N/A 1993 Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Const. Code: PS Spec S-C-MBOO-Edition N/A_ Addenda, Code Class II Cases:N/A__ _______ _ Page _L of _.2._ FORM NR-1 A'rl'ACHMENT Code Job Package No.: PS93-007 Work performed by: Public Service Electric & Gas Co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 2. Owner: Public Service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 3. Location: Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System: Reactor Coolant Nuclear Class: --=I=I"-----
==================================================================
ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ------------------------------------------------------------------------------ ID of Modified: 2C-PRG-2435 Name of Manufacturer: PSE&G N /A NIA N/A N/A 1993 No Serial No. Nat'l. Bd. Jurist No. Other Year Built __ Replacement Const. Code: PS Spec S-C-MBOO-Edition NLA._ Addenda, Code Class II Code Cases:N/A MDS-043 ============================================================================== Name of Manufacturer:
- ID of Component Replaced:
- -----------------------------
Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: ---Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: 2C-PRH-2439 Name of Manufacturer: N/A N/A N/A N/A Serial No. Nat'l. Bd. Jurist No. Other Year Built Replacement Const. Code: PS Spec S-C-MBOO-Edition n/A No ----------- AS ME Code Stamp'd.? Addenda, Code Class II Code Cases: N /A --04 3 ...=......:..=-..___
==================================================================
ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class Code Cases: ----ID of Modified: ______________________ _ Name of Manufacturer: PSE&G N /A N/A N/A =N-/=A,___ Serial No. Nat'l. Bd. Jurist No. Other .Replacement Const. Code: PS Spec S-C-MBOO-Code Cases:NcA 1993 No Ye a r Built ASME Code Stamp'd.? Edition NLA._ Addenda, Code Class II ============================================================================== Page _L of FORM NR-1 ATTACHMENT Code Job Package No.: PS93-007 Work performed by: Public Service Electric & Gas Co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 2. Owner: Public Service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 3. Location: Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System: Reactor Coolant Nuclear Class:
==================================================================
ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: ---Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID Of Modified: 2C-PRS-2438 Name of Manufacturer: PSE&G N /A N/A N/A N/A 1993 _________ _ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: PS Spec S-C-MBOO-Edition NL.A_ Addenda, Code Class II Code Cases:N/A__ MDS-043 ============================================================================== Name of Manufacturer:
- ID of Component Replaced:
Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: __ _ Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: 2C-PRG-2437 Name of Manufacturer: N/A N/A N/A N/A . 1993 Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: PS Spec S-C-MBOO-Edition Addenda, Code Class II Code Cases:N/A __ -* 043 _________ _ ============================================================================== ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code cases: ---Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: Name of Manufacturer: N/A N/A N/A N/A__ 1993 Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Const. Code: PS Spec S-C-MBOO-Edition NL.A_ Addenda, Code Class II Cases:N/A
==================================================================
Page _..2_ of FORM NR-1 ATTACHMENT Code Job Package No.: PS93-007 **1. Work performed by: Public Service Electric & Gas Co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 2. Owner: Public Service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 3. Location: Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4. System: Reactor Coolant Nuclear Class:
==================================================================
ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: ----Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: 2C-PRSN-401 Name of Manufacturer: ________________________ _ N/A N/A N/A N/A 1993 No Serial No. Nat'l. Bd. Jurist No. Other Year Built Replacement Const. Code: PS Spec S-C-MBOO-Edition N/A_ Addenda, Code Class II Code Cases:N/A MDS-043 ============================================================================== Name of Manufacturer:
- ID of Component Replaced:
Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code cases: ---Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: 2C-PRH-243 =-=;.._::-="'--=-:.=------------------------- Name of Manufacturer: N/A N/A N/A N/A__ 1993 No _________ _ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: PS Spec S-C-MBOO-Edition nL.A__ Addenda, Code Class II Code Cases:N/A
- 043 _________
_ ============================================================================== ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Original Const. Code: Code Cases: ---Other Year Built ASME Code Stamp'd.? Edition Addenda, Code Class ID of Modified: 2C-PRS-2561 N am e of Manufacturer: N/A N/A N/A N/A 1993 Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Const. Code: PS Spec S-C-MBOO-Edition NLA__ Addenda, Code Class II ' ,.,Code Cases:N/A__ ==============================================================================}}