Public Service Electric and Gas Company Joseph J. Hagan Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1200 Vice President - Nuclear Operations MAY 111995 LR-N95068 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

INSERVICE INSPECTION ACTIVITIES -

90 DAY REPORT EIGHTH REFUELING OUTAGE SALEM GENERATING STATION UNIT NO. 2 DOCKET NO. 50-311 Public Service Electric & Gas Company (PSE&G) hereby provides in the enclosure to this letter, the Ninety (90) Day Report for Inservice Inspection (ISI) activities conducted at the Salem Generating Station Unit No. 2 during the eighth refueling outage.

This report is submitted in accordance with Section 4.0.5 of Appendix A to the Technical Specifications for Salem Generating Station and Article IWA-6220(c) of Section XI of the ASME Boiler and Pressure Vessel Code. of this submittal consists of Form NIS-1,"0wners Data Report for Inservice Inspection", outage ISI Examination Results for the Second Interval, First Period (RF94) and Forms NIS-2 and/or NR-1 "Owners Report for Repairs and Replacements."

Should there be any questions with regard to this submittal, please do not hesitate to contact us.

Sincerely,

/----~-------

~5~52A30255 950511

-~\\

Q DOCK 05000311 PDR

Document Control Desk LR-N95068 2

C Mr. T. T. Martin, Administrator - Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 MAY 111995 Mr. L. N. Olshan, Licensing Project Manager - Salem U. S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mail Stop 14E21 Rockville, MD 20852 Mr. C. Marschall - Salem (S09)

USNRC Senior Resident Inspector

  • Mr. K. Tosch, Manager, IV NJ Department of Environmental Protection Division of 'Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Emanuel J. Mossa Assistant Director New Jersey Department of Labor and Industry PO Box 1503, Labor and Industry Building Trenton, NJ 08625 95-4933