Finding | |
---|---|
Title | Failure to Incorporate Minimum AFW Flow Requirement into Emergency Procedures |
Description | The inspectors identified a finding of very low safety significance (Green) and associated Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the failure to ensure a minimum AFW flow of 275 gpm as specified in the accident analysis for the Loss of Normal Feedwater event. This finding was entered into the licensees corrective action program. The performance deficiency was associated with the Mitigating Systems Cornerstone attribute of design control and was determined to be more than minor because, if left uncorrected, it would have the potential to lead to a more significant safety concern. Specifically, an AFW flow rate of less than 275 gpm as specified in the procedures did not ensure the pressurizer would not become water solid and cause an over-pressure condition within the Reactor Coolant System during the Loss of Normal Feedwater. The finding screened as of very low safety significance (Green) because the finding was not a design or qualification deficiency, did not represent a loss of system safety function, and did not screen as potentially risk-significant due to a seismic, flooding, or severe weather initiating event. This finding had a cross-cutting aspect in the area of human performance, resources because the licensee did not maintain design documentation in a complete and accurate manner. Specifically, the licensee failed to maintain Emergency Procedures consistent with the design basis analysis for LONF. |
Site: | Point Beach ![]() |
---|---|
Report | IR 05000266/2011009 Section 1R21 |
Date counted | Sep 30, 2011 (2011Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | M Munir A Dahbur C Moore B Sherbin J Bozga J Nicely C Tilton C Nickell |
CCA | H.7, Documentation |
INPO aspect | WP.3 |
' | |