Finding | |
|---|---|
| Title | Failure to Perform an Operability Evaluation for Leakage Inside Containment |
| Description | A finding of very low safety significance and an associated non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, was identified by the inspectors for the licensees failure to perform an operability evaluation of leakage inside containment when it was identified in September 2010. Specifically, on September 26, 2010, condition report AR01397092 identified increased leakage and a related work order was initiated to inspect Unit 1 containment for the leakage source; however, an evaluation of the leak and leak location/source was not performed as required by licensee procedures. The finding was determined to be more than minor because it was associated with the Barrier Integrity Cornerstone attribute of structure, system, and component and barrier performance, and adversely affected the cornerstone objective of providing reasonable assurance that physical design barriers, specifically the containment, would be able to protect the public from radionuclide releases caused by accidents or events. The inspectors answered No to all of the questions in the Containment Barrier column of Table 4a of Inspection Manual Chapter 0609, Significance Determination Process, Attachment 0609.04, Phase 1 - Initial Screening and Characterization of Findings; therefore, the finding screened as very low safety significance. The finding has a cross-cutting aspect in the area of human performance, decision-making, because the licensee did not use conservative assumptions during the decision-making and review process associated with the degraded condition (H.1(b)). |
| Site: | Point Beach |
|---|---|
| Report | IR 05000266/2011003 Section 1R22 |
| Date counted | Jun 30, 2011 (2011Q2) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.22 |
| Inspectors (proximate) | D Jones K Carrington M Thorpe Kavanaugh N Feliz Adomo P Cardona Morales S Burton T Bilik |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |
Finding - Point Beach - IR 05000266/2011003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Point Beach) @ 2011Q2
Self-Identified List (Point Beach)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||