Finding | |
---|---|
Title | Failure to Assure Configuration Control of Safety Related Systems |
Description | The inspectors identified a noncited violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the failure to review the suitability of leaving test fittings on reactor coolant system flow transmitter equalizing block drain ports instead of the design specified manifold plugs. As corrective action, the licensee replaced the test fittings with the correct drain plugs. This finding was entered into the licensees corrective action program as Condition Report CR-GGN-2011-04485. This finding is more than minor because it is associated with the design control attribute of the Mitigating System Cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Using Inspection Manual Chapter 0609.04, Phase 1 - Initial Screening and Characterization of Findings, inspectors determined that the finding was of very low safety significance (Green) because it was a design or qualification deficiency confirmed not to result in loss of operability of functionality, did not represent a loss of a system safety function, and did not screen as potentially risk significant due to a seismic, flooding, or severe weather initiating event. The inspectors determined that the finding had a cross-cutting aspect in the area of human performance, associated with work practices, because the licensee failed to ensure that human error prevention techniques, such as holding pre-job briefings, self- and peer-checking, and proper documentation of activities were utilized such that work activities were performed safely and personnel did not proceed in the face of uncertainty or unexpected circumstances Specifically, the licensee failed to review the suitability of installing test and brass fittings on pressure, differential pressure and flow transmitter block valve drain ports instead of the design specified manifold plugs. |
Site: | Grand Gulf |
---|---|
Report | IR 05000416/2011003 Section 1R12 |
Date counted | Jun 30, 2011 (2011Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.12 |
Inspectors (proximate) | J Drake M Baquera R Kumana R Smith V Gaddy A Fairbanks B Rice E Uribe J Braisted |
CCA | H.12, Avoid Complacency |
INPO aspect | QA.4 |
' | |