Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
05000344/LER-1982-007, Updated LER 82-007/01T-0:on 820514,during Review of Revised Containment DBA Analysis,Nonconservative Spray Modeling Error Identified in Model Used to Justify Tech Spec 3.6.1.4 Re Max Positive Containment Operating Pressure30 July 1982Updated LER 82-007/01T-0:on 820514,during Review of Revised Containment DBA Analysis,Nonconservative Spray Modeling Error Identified in Model Used to Justify Tech Spec 3.6.1.4 Re Max Positive Containment Operating Pressure
ML17275A8029 January 1981Part 21 Rept Re Failure to Provide Proper Control Components Intl Valves Supplying 2 Gpm Flow When in Closed Position. Caused by Valve Failure.Affected Licensees Notified & Selection of Alternative Method Underway
ML17352A86931 May 1993Technical Rept, Assessment of Aging Degradation of Civil/ Structural Features at Selected Operating Nuclear Power Plants.Boric Acid
Coatings
Operating Basis Earthquake
Tornado Missile Protection
Earthquake
ML20054J05818 June 1982Safety Evaluation Granting Relief from ASME Code Section XI Visual Exam Requirement for Five Specific Class 3 Components
ML20054L42315 June 1982Ro:Informing That Seismic Monitoring Instrumentation Will Be Taken Out of Svc on 820607 for More than 30 Days Due to Annual Calibr,Design Change to Mounting Base & Containment Integrated Leak Rate Test
ML20054M13510 June 1982Monthly Operating Rept for May 1982
ML20055A1448 July 1982Monthly Operating Rept for June 1982
ML20055A6669 July 1982Ro:During June 1982,pieces of Metal,Originally Installed as Thermal Sleeves on 10-inch Safety Injection Connections, Found Below Lower Core Plate.Sleeves Broke Loose During First 6 Yrs of Operation.All Metal Pieces Removed
ML20055B7731 July 1982RO 82-01,Revision 1:on 820116,engineering Investigation Determined That Emergency Diesel Generator B Inoperable When 120-volt Ac Preferred Instrument Bus Y24 Supplied from Nonpreferred Instrument Bus Y02.Design Change Complete
ML20055C40231 December 1989Annual Rept of Trojan Nuclear Plant for 1989
ML20055C75318 June 1990Safety Evaluation Supporting Amend 161 to License NPF-1
ML20055F88731 December 1989Eugene Water & Electric Board 1989 Annual Rept
ML20055F88931 December 1989Portland General Corp 1989 Annual Rept
ML20055F89031 December 1989Pacific Power & Light Co 1989 Annual Rept
ML20056B0332 August 1990Special Rept:On 900626,condenser Air Ejector Noble Gas Effluent Monitor PERM-6C Declared Inoperable.Caused by High Flow Rates of off-gases Present.Chiller Repaired & Monitor Placed in Svc
ML20056C67630 June 1993Monthly Operating Rept for June 1993 for Trojan Nuclear Plant
ML20056E51731 August 1993Technical Review Rept, Tardy Licensee Actions
ML20056G05431 December 1988Revised Annual Rept for 1988,correcting Values in Solid Waste & Irradiated Fuel Shipments Tables 9 & 10
ML20056G05531 December 1989Revised Annual Rept for 1989,correcting Values in Solid Waste & Irradiated Fuel Shipments Tables 9 & 10
ML20056G05731 December 1990Revised Annual Rept for 1990,correcting Values in Solid Waste & Irradiated Fuel Shipments Tables 9 & 10
ML20056G05931 December 1991Revised Annual Rept for 1991,correcting Values in Solid Waste & Irradiated Fuel Shipments Tables 9 & 10
ML20056G06031 December 1992Revised Annual Rept for 1992,correcting Values in Solid Waste & Irradiated Fuel Shipments Tables 9 & 10
ML20056G89531 December 1992Portland General Corp 1992 Annual Rept
ML20056G89731 December 1992Eugene Water & Electric Board 1992 Annual Rept
ML20056G90031 December 1992Pacificorp Annual Rept 1992
ML20056G90931 August 1993Monthly Operating Rept for Aug 1993 for Trojan Nuclear Plant
ML20056H14830 August 1993Special Rept 01-93:on 930804,Deluge Sys 19 Discovered Inoperable During Surveillance Testing.Caused by Failure of Deluge Valve Due to Normal Wear.Required Fire Watches Established & Maintained Until Deluge Sys Restored
ML20057B32316 September 1993Special Rept 93-02:on 930831,discovered a Wind Speed Instrument Channel to Have Intermittent Fault at Low Speed Due to Unknown Cause.Replaced Wind Speed Processor Card
ML20057D07922 September 1993Safety Evaluation Supporting Amend 192 to License NPF-1
ML20057D99530 September 1993Safety Evaluation Accepting Licensee Request for Exemption from Certain 10CFR50 Requirements for Emergency Planning for Plant
ML20057F93030 September 1993Monthly Operating Rept for Sept 1993 for Trojan Nuclear Plant
ML20058A45127 January 1981Partially Withheld Info Secy That Informs Commission of Appeal Board Decision
ML20058C67431 October 1993Monthly Operating Rept for Oct 1993 for Tnp
ML20058D11431 July 1982Safety Evaluation Re Loose Thermal Sleeves
ML20058D64115 October 1990Trojan Nuclear Plant Cycle 13 Startup & Power Escalation Physics Testing Rept
ML20058D64731 December 1989Irradiation of Four 17x17 Mark-BW Lead Assemblies in Trojan Cycle 13 Design Rept
ML20058F39730 September 1990Rev 1 to Monthly Operating Rept for Sept 1990 for Trojan Nuclear Plant
ML20058K1396 December 1993Safety Evaluation Supporting Amend 193 to License NPF-1
ML20058L2122 August 1990Special Rept:On 900720,discovered Circuit Breaker,Which Supplies Stated Fire Pump,In Open Position.Pump Would Have Been Unable to Automatically Start.Caused by Fire Water Sys Low Pressure While Filling Sprinkler.Personnel Counseled
ML20058L5642 August 1990Safety Evaluation Concluding That Operable Instrumented Ammonia Detection Capability Unncessary for Protection of Control Room Personnel in Event of Spill of Anhydrous Ammonia in Vicinity of Plant
ML20058L80030 November 1993Monthly Operating Rept for Nov 1993 for Trojan Nuclear Plant
ML20058N08810 August 1990Special Rept:On 900710,review Revealed That 99 Fire Dampers Classified as Tech Spec Fire Barriers.Qa Audit in Fall of 1989 Identified Installation Requirements for Fire Dampers Failed to Permit Testing.Repairs to Be Completed by 900928Fire Barrier