 Issue dateTitleTopic
ML17352B2511 October 1993LER 93-019-00:on 930903,RHR Pump 1A Inadvertently Started Due to Personnel Error.Pump Immediately Secured & Individual Involved Counselled on Importance of self-check.W/931001 Ltr
ML18041A12514 September 1984Rev 4 to, 180-Day Rept in Response to IE Bulletin 80-11 for Dresden Nuclear Power Station Units 2 & 3.Safe Shutdown
Safe Shutdown Earthquake
Probabilistic Risk Assessment
Operating Basis Earthquake
Tornado Generated Missile
Earthquake
ML18052B55424 August 1987LER 87-015-00:on 870731,capacitor Failed on 1B Reactor Bldg & Refuel Floor Radiation Monitors Resulting in Safety Feature Actuation.Caused by Normal Aging.Capacitor replaced.W/870825 Ltr
ML19207B1406 August 1979Monthly Operating Rept for Jul 1979
ML19208A04521 August 1979LER 79-016/03L-0:on 790815,HPCI Turbine Area Temp Switch Found to Trip Above Tech Spec Limits.Caused by Setpoint Drift.Switch Replaced & Tested Satisfactorily
ML19208A11210 August 1979LER 79-024/03L-0:on 790724,pressure Suppression Chamber Reactor Bldg Vacuum Breaker Pressure Switch Was Found to Actuate Below Limiting Condition for Operation Level.Caused by Instrument Setpoint Drift.Switch Recalibr
ML19208A82110 September 1979Monthly Operating Rept for Aug 1979
ML19209B58221 September 1979LER 79-017/03L-0:on 790822,during Monthly Surveillance, Division 1 Alarm on Vacuum Breaker Failed to Annunciate Upon Valve Opening.Caused by Limit Switch Problem.Vacuum Breaker Limit Switches Will Be Inspected During Outage
ML19209C42925 September 1979LER 79-018/03L-0:on 790905,spray Valve Mo 2-1001-23B Found to Trip Breaker When Operated.Caused by Broken Bolt in Valve Motor Operator.All Four Bolts on Motor Operator Replaced
ML19209C6112 October 1979Monthly Operating Repts for Sept 1979
ML19209D0809 October 1979LER 79-019/03L-0:on 790910,reactor Bldg Vent Monitor Failed Downscale.Caused by Two Blown Fuses in Monitor Circuitry & Two Failed Capacitors in Monitor Power Supply.New Capacitors Installed & Fuses Replaced
ML19210C6666 November 1979LER 79-032/01T-0:on 791026,piping Restraints 1/2-7504-164 & 165 Had Safety Factor of Less than Two.Standby Gas Treatment Sys a & B Declared Inoperable.Caused by Improper Design of Safety Factors.Restraints ModifiedDesign basis earthquake
ML19210C6701 November 1979LER 79-030/03L-0:on 791012,GEB-type Fuel Exposures Exceeded Max Averge Planner Linear heat-generation Rate.Caused by Failure to Specify Limits for High Exposure GEB-type Fuel. Curves Extended to Exposure Limit
ML19210C6841 November 1979LER 79-033/01T-0:on 791020,piping Restraint 1/2-7509-R149 Had Safety Factor of Less than Two.Standby Gas Treatment Sys a & B Declared Inoperable.Caused by Improper Design Safety Factors.Restraint Modified
ML19220D0484 May 1979LER 79-020/03L-0 on 790413:measured Leakage for Personnel Air Lock Was 54.63 Std Cubic Ft/H.Leakage Identified Through Outer Lower Handwell.Shaft Packing Was Replaced & Air Lock Retested
ML19225B23030 June 1979Monthly Operating Rept for June 1979
ML19225B51522 June 1979LER 79-012/03L-0 on 790622:nut Inadvertantly Droppoed Into Diesel Generator Winding During Preventive Maint.Outage Time of Generator Extended 20 Minutes Beyond 1.5-h Time Limit. Caused by Personnel Error
ML19241A93127 June 1979LER 79-021/03L-0 on 790601:drywell-to-suppression Chamber Vacuum Breaker Div 11 Alarm Sys Breaker Found Tripped on 790410 & Reported as non-reportable.Should Be Reclassified. Cause of Breaker Trip Unknown
ML19241A95020 June 1979LER 79-020/03L-0 on 790525:quarterly MSIV Closure Timing Surveillance Performed & MSIV Closed in 6-s Instead of 5-s. Caused by Varied Speed Control Valve Adjustment on Hydraulic Cylinder
ML19242D21030 July 1979LER 79-023/03L-0 on 790717:high Pressure Switch in Safety Relief Valve Controller Found Inoperable During Reactor High Pressure Automatic Blowdown Functional test,QIS-40.Caused by Loosened Lead Wire from Switch to Terminal
ML19246C4735 July 1979LER 79-011/03L-1 on 790521:investigation of Cable Pans Found Three Cables Not Installed Per Tabulation Drawings.Caused by Error in Cable Routing Made During Metal Const.Cables to Be Rerouted During Nov 1979 Refueling Outage
ML19246C48413 July 1979LER 79-022/03L-0 on 790622:after Returning Unit 1 Diesel Generator to Svc,Following Monthly Preventive Maint Insp, Fuel Line Leak Was Discovered.Caused by Worn Gasket on Fuel Line Filter.Filter Gasket Replaced
ML19248C59022 June 1979LER 79-037/03L-0 on 790530:after Operator Closed Bus 24-1 Auxiliary Cabinet Door,Diesel Generator Differential Fault Alarmed,Resulting in Trip to Faul Relay W/Target Up.Caused by Closing Auxiliary Door Excessively Hard
ML19250B82916 October 1979LER 79-028/03L-0:on 790924,during Monthly Procedure Qos 1100-1,required 1,275 Psig Discharge Pressure Could Not Be Achieved on Subsys A.Caused by Setpoint Drift on RV-1-1105A.Valve Replaced & Subsys Returned to Svc
ML19250B9618 October 1979LER 79-026/03L-0:on 790914,during Reactor Shutdown,Outboard MSIV A0-1-203-2C Would Not Fully Close.Caused by Sticking Air Pilot Valve.Pilot Disassembled,Inspected & Replaced. MSIV Stroked & Timed to Close in 3.9-s
ML19250B99931 December 1978Load Line Limit Analysis License Amend Submittal.
ML19253A91821 August 1979LER 79-025/03L-0:on 790813,while Performing Hpic Turbine Area High Temp Isolation Calibr,Temp Switch TS 1-2371A Was Found to Trip at 203 F.Caused by Setpoint Drift. Switch Was Recalibr & Successfully Retested
ML19253C31714 November 1979LER 79-023/03L-0:on 791016,level Switch LIS 2-263-72A Failed to Trip During Calibr.Caused by Failure of One Mercury Wetted Magnetic Switch Encl in Level Indicator.New Switch Installed & Tested Satisfactorily
ML19253C32814 November 1979LER 79-024/03L-0:on 791025,vacuum Breaker AO 2-1601-20B Failed to Open During Calibr & Functional Test.Caused by Component Failure.Solenoid Valve 2-1601-50B Rebuilt 791025
ML19253C33316 November 1979LER 79-026/03L-0:on 791022,during Turbine First Stage Low Pressure Calibr Procedure Qis 55-1,pressure Switch PS-2-504C Tripped Above Tech Spec Limit.Caused by Instrument Set Point Drift.Pressure Switch Recalibr
ML19253C34721 November 1979LER 79-025/03L-0:on 791026,during Lcpi Motor Operated Valve Operability Test,Motor Control Breaker Tripped on Thermal Overload.Caused by Tripping Circuit Breaker.Motor Meggared
ML19254D82623 October 1979LER 79-056/03L-0:on 791004,fuses for Normal & Reserve Power to Relief Valve Blew,Rendering Relief Valve Inoperable. Caused by Socket Shorting While Changing Closed Indication Light Bulb for 2-D Electromatic Relief Valve
ML19254E98419 October 1979LER 79-027/03L-0:on 790921,Tech Specs Exceeded for Water Reactor Conductivity & Chloride Concentration.Caused by Personnel Error.All Personnel Informed of Importance of Knowing Surveillance Limits
ML19254F01815 October 1979LER 79-020/03L-0:on 790919,three Grinnell Hydraulic Snubbers Found to Have Empty Reservoirs.Caused by Excess Leakage Through Defective Gaskets.Snubbers Repaired by Installing New Oil Resevoirs and Seals
ML19254F27826 October 1979LER 79-029/03L-0:on 790929,false High Radiation Signal Automatically Started Reactor Bldg Ventilation Sys & Standby Gas Treatment Sys.Caused by Burned Coil on Relay 1-1705-101. Relay Coil Replaced
ML19254F8936 November 1979LER 79-033/03L-0:on 791025,while Performing Diesel Generator Monthly Load Test,Unit 1/2 Diesel Generator Failed to Accept Full Rated Load of 2,500 Kw.Caused by Plugged Oil Filter. Filters Replaced & Governors Adjusted
ML19256A13124 October 1978LER 78-054/03L-0:on 780930 Torus Vacuum Relief Valve AO-1601-20B Would Not Close.Alarm Received.Valve Fully Open. Caused by Blown Fuse in Control Circuit Due to Short in AO-1601-203 Air Operated Solenoid Valve
ML19256B18517 January 1979LER 79-002/01T-0 on 790103:HPCI Turbine Failed to Start During Quarterly Flow Test.Caused by Misadjustment of the Interlock Dump Valve Operating Lever
ML19256E50525 October 1979LER 79-022/03L-0:on 791005,vacuum Breaker AO 2-1601-32B Failed to Give Full Open Red Light Indication.Caused by Valve Position Indicating Switch Problem.Corrective Actions to Be Completed During Nov 1979 Refueling Outage
ML19256F25330 November 1979LER 79-035/03L-0:on 791109,RHR Svc Water Line Supports Found W/Safety Factor Less than Two.Containment Cooling Loop Declared Inoperable.Caused by Design Deficiency.Supports Modified for Factor Above Four,Loop Returned to Svc
ML19256G02621 December 1979LER 79-064/03L-0:on 791124,torus-to-drywell Vacuum Breaker Found Inoperable.Caused by Swollen Teflon Shaft Bushings. Bushings Machined to Required Clearance & Study Initiated Re Applicability of Teflon as Bushing Material
ML19257A7177 December 1979LER 79-036/03L-0:on 791115,during in-place Freon Test on 1/2-B-7509 Standby Gas Treatment Sys,Freon Penetration Through Charcoal Absorbers Was 1.05%.Caused by Faulty Compressing of Internal Gaskets.New Gaskets Installed
ML19257A72224 December 1979LER 79-027/03L-0:on 791126,six Occurrences Identified Whereby Excessive Leakages Were Measured W/Respect to Primary Containment Isolation Valves During Local Leak Rate Testing.All Valves to Be Repaired & Tested
ML19257A72711 December 1979LER 79-037/03L-0:on 791116,diesel Generator Starting Air Supply Valves 1/2-4699-121 Locked in Closed Position.Caused by Operator Error.Generator Not Rendered Inoperable Due to Redundant Valve.Valve Opened & Locked
ML19257A72810 December 1979LER 79-038/01T-0:on 791128,scram & ECCS Initiation Setpoints Set Lower than Required by Tech Specs.Caused by Initial Instrument Ref Leg Calculations Based on Temp of 135 F. Indicating Switches RecalibrReactor Vessel Water Level
ML19257B1973 January 1980Monthly Operating Repts for Dec 1979
ML19257B2734 January 1980LER 79-042/03L-0:on 791214,while Performing MSIV Closure Timing Surveillance,Ao 1-203-1C Found to Close in 5.2-s. Caused by Varied Speed Control Valve Adjustment on Hydraulic Control Cylinder.Valve Adjusted
ML19257B38831 December 1979LER 79-028/03L-0:on 791205,while Performing Reactor Core Isolation Cooling Turbine Area High Temp Calibr,Four Temp Switches Tripped in Excess of Tech Spec Limit.Caused by Instrument Setpoint Drift.Switches Recalibr
ML19257B4122 January 1980LER 79-029/03L-0:on 791206,prior to Performing Leak Test, Primary Containment Oxygen Analyzer Return Isolation Valve AO 2-8803 Would Not Fully Close.Caused by Binding of Valve Stem & Valve Packing.Valve Removed & Repacked
ML19257C61721 January 1980LER 79-030/03L-0:on 791228,while Performing Surveillance Procedure Qos 30-2,bed Plate Drain Valve AO 2-4999-59 Failed to Close When Float Switch Was Activated.Caused by Component Failure.Corrective Maint Underway