LER 78-035/03L-0:on 780408,hydrogen Dilution Blower 1-1 Motor Breaker Tripped on Overload During Test Run.Caused by Sticking Suction Check Valve.Valves Cleaned & re-assembled. Check Valve Internals Removal Requested
ML19326A435
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 05/04/1978
From: Isley T
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19326A434 List:
References
LER-78-035-03L, LER-78-35-3L, NUDOCS 8002030257