Safety Evaluation Accepting Licensee Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves
ML20195K287
Person / Time
Site: Davis Besse 
Issue date: 06/16/1999
From:
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20195K278 List:
References
GL-95-07, GL-95-7, NUDOCS 9906220050
Download: ML20195K287 (3)


Text

F:

as:o y

1.

UNITED STATES NUCLEAR REGULATORY COMMISSION

)

wAswInstou, p.c. mess.oooi SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION LICENSEE RESPONSE TO GENERIC LETTER 95-07. " PRESSURE LOCKING AND THERMAL BINDING OF SAFETY-RELATED POWER-OPERATED GATE VALVES."

FIRSTENERGY NUCLEAR OPERATING COMPANY DAVIS-BESSE NUCLEAR POWER STATION. UNIT 1 DOCKET NUMBER 50-346

1.0 INTRODUCTION

Pressure locking'and thermal binding represent potential common-cause failure mechanisms that can render redundant safety systems incapable of performing their safety functions. The identification of susceptible valves and the determination of when the phenomena might occur require a thorough knowledge of components, systems, and plant operations. Pressure locking occurs in flexible-wedge and double-disk gate valves when fluid becomes pressurized inside the valve bonnet and the actuator is not capable of overcoming the additional thrust requirements resulting from the differential pressure created across both valve disks by the pressurized fluid in the valve bonnet. Thermal binding is generally associated with a wedge gate valve that is closed while the system is hot and then is allowed to cool before an attempt is made to open the valve.

Pressure locking or thermal binding occurs as a result of the valve design characteristics (wedge and valve body configuration, flexibility, and material thermal coefficients) when the valve is subjected to specific pressures and temperatures during various modes of plant operation. Operating experience indicates that these situations were not always considered in many plants as part of the design basis for valves.

2.0 REGULATORY REQUIREMENTS 10 CFR Part 50 (Appendix A, General Design Criteria 1 and 4) and plant licensing safety analyses require or commit (or both) that licensees design and test safety-related components and systems to provide adequate assurance that those systems can perform their safety functions. Otherindividual criteria in Appendix A to 10 CFR Part 50 apply to specific systems.

In accordance with those regulations and licensing commitments, and under the additional provisions of 10 CFR Part 50 (Appendix B, Criterion XVI), licensees are expected to act to ensure that safety-related power-operated gate valves susceptible to pressure locking or thermal binding are capable of performing their required safety functions.

9906220050 990616 PDR ADOCK 05000346 P

PDR

F

.c 7

o..

]

2 On August 17,1995, the NRC issued Generic Letter (GL) 95-07, " Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves," to request that licensees take certain actions to ensure those safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases of the facility. GL 95-07 requested that each licensee, within 180 days of the date of issuance of the generic letter (1) evaluate the operational configurations of safety-related power-operated gate valves in its plant to identify valves that are susceptible to pressure locking or thermal binding, and (2) perform further analyses and take needed corrective actions (orjustify longer schedules) to ensure that the susceptible valves, identified in (1) above, are capable of performing their intended safety functions under all modes of plant operation, including test configurations. In addition,-

GL 95-07 requested that licensees, within 180 days of the date of issuance of the generic letter, provide to the NRC a summary description of (1) the susceptibility evaluation used to determine that valves are or ars, not susceptible to pressure locking or thermal binding, (2) the results of the susceptibility evaluation, including a listing of the susceptible valves identified, and (3) the corrective actions, or other dispositioning, for the valves identified as susceptible to pressure locking or thermal binding. The NRC iss'ued GL 95-07 as a " compliance backfit" pursuant to 10 CFR 50.109(a)(4)(i) because modification may be necessary to bring facilities

{

into compliance with the rules of the Commission referenced above, in a letter of February 13,1996, Toledo Edison submitted its 180-day response to GL 95-07 for the Davis-Besse Nuclear. Power Station, Unit 1. The NRC staff reviewed the licensee's submittal and requested additional information in a letter dated June 10,1996. In a letter of July 18,1996, the licensee provided the additional information.

3.0 STAFF EVALUATION 3.1 Scope of Licensee's Review

, GL 95-07 requested that licensees evaluate the operational configurations of safety-related power-operated gate valves in their plants to identify valves that are susceptible to pressure locking or thermal binding.- The Toledo Edison letters of February 13, and July 18,1996,.

described the scope of valves evaluated in response to GL 95-07. The NRC staff has

, reviewed the scope of the licensee's susceptibility evaluation performed in response to GL 95-07 and found it complete and acceptable. The licensee did not include reactor coolant

' system hot leg letdown to decay heat removal valves, DH 11, DH 12, DH 1517 and DH 1518, in the scope of GL 95-07 because these valves are used during plant conditions below hot

~

shutdown. The licensing basis for Davis-Besse Nuclear Power Station, Unit 1 is hot shutdown.

The criteria for determining the scope of power-operated valves for GL 95-07 are consistent

' with the staff's acceptance of the scope of motor-operated valves associated with GL 89-10

" Safety-Related Motor-Operated Valve Testing and Surveillance."

,_ w ___.. _. _

- - - - - +

h.

\\

e-3.2 Corrective Actions GL 95-07 requested that licensees, within ~180 days, perform further analyses as appropriate, and take appiepitt corrective actions (orjustify longer schedules), to ensure that the susceptible valves identified are capable of performing their intended safety function under all modes of plant operation, including test configurations. The licensee's submittals discussed corrective actions to address potential pressure-locking and thermal-binding problems. The staff's evaluation of the licensee's actions is discucsed in the following paragraphs:

a.

The licensee stated that the following valves were modified to eliminate the potential for pressurelocking:

RC 11 Pressurizer Power Operated Relief Valve Block DH 63 Decay Heat Supply to High Pressure injection Pump Suction DH64 Decay Heat Supply to High Pressure injection Pump Suction The staff finds that physical modification to valves susceptible to pressure locking is an appropriate corrective action to ensure operability of the valves and is thus acceptable.

b.

The licensee stated that all flexible and solid wedge gate valves in the scope of

~ GL 95-07 were evaluated for thermal binding. When evaluating whether valves were susceptible to thermal binding, the licensee assumed that thermal binding would not occur below specific temperature thresholds. Operating conditions for the pressurizer vent stop valve, RC 200, and the pressurizer sample isolation valves, RC 239A/B, exceeded these temperature liniitations; however, operational history demonstrated that the valves are not susceptible to thermal binding. The screening criteria used by the licensee appear to provide a reasonable approach to identify those valves that might be susceptible to thermal binding. Until more definitive industry criteria are developed, the staff concludes that the licensee's actions to address thermal binding of gate valves are acceptable.

4.0 CONCLUSION

On the basis of this evaluation, the NRC staff finds that the licensee has performed appropriate evaluations of the operational configurations of safety-related power-operated gate valves to identify valves at Davis-Besse Nuclear Power Station, Unit 1, that are susceptible to pressure locking or thermal binding. In addition, the NRC staff finds that the licensee has taken appropriate corrective actions to ensure that these valves are capable of performing their intended safety functions. Therefore, the staff concludes that the licensee has

' adequately addressed the requested actions discussed in GL 95-07.

Principal Contributor: S. Tingen, NRR Date: June 16,~1999

-