LER 79-085/03L-0 on 790722:containment post-accident Radiation Monitor Declared Inoperable.Caused by Component Failure.Pump Replaced W/Rebuilt Pump,Surveillance Tested & Declared Operable
ML19249A529
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/17/1979
From: Jensen C
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19249A526 List:
References
LER-79-085-03L, LER-79-85-3L, NUDOCS 7908230529