ML20133N405
ML20133N405 | |
Person / Time | |
---|---|
Site: | South Texas |
Issue date: | 01/22/1997 |
From: | Hodge C NRC (Affiliation Not Assigned) |
To: | Alexion T NRC (Affiliation Not Assigned) |
References | |
NUDOCS 9701230280 | |
Download: ML20133N405 (52) | |
Text
I January 22, 1997 YkY%
)
MEMORANDUM FOR: Thomas W. Alexion Project Manager, South Texas Project Project Directorate IV-1 Office of Nuclear Reactor Regulation THROUGH: Robert L. Dennig, Chie:f [ Original signed by]
Section B Events Assessment and Generic Communications Branch Office of Nuclear Reactor Regulation FROM: C. Vern Hodge Part 21 Coordinator Events Assessment and Generic Communications Branch Office of Nuclear Reactor Regulation
SUBJECT:
REQUESTED LIST OF RECENT PART 21 REPORTS In response to his telephone request, please transmit on the docket the attached computer listing of recent Part 21 reports to Rick Foote of the Houston Lighting & Power Company, the licensee for the South Texas Project.
To minimize the effort required to furnish this response, the 50-page listing is obtained from a standard report form in the NRC internal Events Tracking System.
The listing contains eight fields of use to the NRC staff involved with the review and evaluation of Part 21 related information. To assist Mr. Foote in learning of the concerns reported, we have ordered the individual entries by the vendor or site name. The fields with dates, assigned reviewer, Part 21 log number, and event type have administrative value only and probably will not be of use to non-NRC staff. The report number field may be of interest and use. This field may contain the accession number to identify the document ,
in the NRC Public Document Room (PDR), the number of an event notification report prepared by the NRC Operations Center based upon a phone call received by NRC, or the number of an internal report prepared by regional NRC staff based upon observations, etc. These internal reports are placed in the PDR but are not kept by the PDR.
The items are ordered by vendor name and contain a brief synopsis of each report. The first page of the attachment contains a legend explaining the l meaning of the several columns.
Attachment:
Part 21 Follow-Up Assignments
/
DISTRIBUTION TTMartin CVHodge Central Files ;
AEChaffee DRPM R/F PDR l} d())
RLDennig PECB R/F ,
OFFICE PECB PECB:NRR VHodge (h SC/PEQffdbtfb v-v RDennig DATE 01/P/97 01/ 22797 DOCUMENT: G:\VERN\STX70114.MEM ,
230041 9701230280 970122 PDR ADOCK 05000498 P PDR
4 Attachment PART 21 FOLLOW-UP ASSIGNMENTS l Leaend:
l Assignment Date The date of formal assignment of the Part 21 report to an NRC staff engineer. This date is not necessarily the date of the report but in most case is close to j that date.
Report This column contains ten-digit accession numbers to the NRC Nu Documents System (these reports would be the most accessible to Mr. Foote in the Public l Document Room), five-digit NRC internal event notification numbers, or nine-character NRC internal l morning report numbers.
Closing Date The date of completion of the formal assignment, including documentation in the NRC internal Events Tracking System.
l l
Vendor Abbreviated names of entities su] plying or associated (vendor, supplier, or plant) wit 1 the report.
l Assigned To The name of the NRC staff engineer receiving the formal assignment.
! Subject Self-explanatory. Part 21 log numbers appearing in this column only have meaning to the NRC internal system for managing these reports.
Part 21 Number Five-digit log numbers for the NRC internal system for l managing these reports. In 1995, this number is unique for each report. In 1996, the reports are I l sequentially numbered (fifth digit) within each issue !
group (third and fourth digits). l Event Type Mnemonic designations pertinent to the NRC internal i system for managing all event information.
l i
I i
s PART 21 FOLLOW-UP ASSIGNME TS SORT > Plant Name QUERY >
CLOSING PART21 EVENT ASSIGNMENT SUBJECT (Event Description) NUMBER TYPE g REPORT DATE VENDOR ASSIGNED TO 08/14/95 0 ABB GREENE T. The short name for this issue is relay eq. The description 94243 TBD of the lead Part 21 report given in the old TOM dBase file is:
94243 F - ASEA BROWN BOVERI REPORTS ON RESULTS OF t IRRADIATION TESTING OF TYPE 27N RELAYS; DEGRADATION FOUND ABOVE TOTAL DOSE OF i 10E3 RADS, GAMMA. LICENSEES NOTIFIED. SEE LOG #921%/92240 &
94273 FOR CORRECTIONS.
Additional related Part 21 reports are described in the closeout section below.
I 0 12/13/95 ABB BIRMINGHAM J. PART 21 LOG #95-226: ABB REPORTS THAT SAN ONOFRE EXFERIENCED 95226 OTH 12/06/95 A FAILURE OF A CONDUCTOR STRIP ON A " SECONDARY DISCONECT DEVICE" ON AN ITE 5HK CIRCUIT BREAKER. THE EFFECT OF THE FAILUPE IS POTENTIAL TO DEFEAT ELECTRICAL CONTROL OF THE BREAKER. MANUAL LOCAL CONTROL WOULD BE NEEDED.
0 03/27/96 ABB SKEEN D. PART 21 LOG #96050 - LETTER REPORT FROM ABB DATED NOVEMBER 96050 OTH 01/25/96 ,
20, 1995. REPORT DETAILS ROOT CAUSE FINDINGS FROM INVESTIGATION OF FAILURES OF POWER SHIELD TRIP UNITS, TYPE SS-13 PART NUMBER 609901-T012, SERIAL NUMBERS 45779 AND 45778. ADVISES THAT PROBLEM CAN BE TRACFD TO DEFECTIVE SOLDER CONNECTIONS AND THAT ABB WILL NOTIFY END USERS.
RELATED TO EN 29426, PART 21 LOG #95213 PREVEIOUSLY "
ASSIGNED. CLOSE0JT UNDER EN 29426.
0 03/27/96 ABB SKEEN D. PART 21 LOG #96051 - FINAL PART 21 REPORT FROM CLINTON DATED 96051 OTH 01/25/96 12/20/95 NOTING RECEIPT OF REPORT FROM FROM ABB DATED NOVEMBER 20, 1995. REPORT DETAILS ROOT CAUSE FINDINGS FROM +
INVESTIGATION OF FAILURES OF POWER SHIELD TRIP UNITS, TYPE SS-13 PART NUMBER 609901-T012, SERI AL NUMBERS 45779 AND t 45778. ADVISES THAT PROBLEM CAN BE TRACED TO DEFECTIVE SOLDER CONNECTIONS AND THAT ABB WILL NOTIFY END USERS.
SUMMARIZES CLINTON EXPERIENCE AND CORRECTIVE ACTIONS.
RELATED TO EN 29426, PART 21 LOG #95213 PREVIOUSLY ASSIGNED.
CLOSEOUT UNDER EN 29426.
9505090013 05/03/95 ABB KOSHY Ts 95126 05/03/95 L
Page:1 01/17/97 ETS-23 I
PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
LSSIGNMEDT CLOSING PART21 EVENT DATE REPORT DATE VENDOR AS$1GNED TO SUBJECT (Event Description) NLNE8ER g CP/18/96 30753 ABB SKEEN D. PART 21 LOG #96620 - A88 RELAY DIVISION REPORTS THAT 96620 QUALIFICATI0P: DOCUMENTATION FOR COM-5 CLASS 1E RELAYS MAY NOT BE IN ORDER. YANKEE ATOMIC REVIEW OF VENDOR REVEALED ISSUE.
OF/10/ % 30752 ABB HODGE V. PART 21 LOG #96620 - A88 RELAY DIVISION REPORTS THAT 96630 QUALIFICATION DOCUMENTATION FOR COM-5 CLASS 1E RELAYS MAY NOT BE IN ORDER.-YANKEE ATOMIC REVIEW OF VENDOR REVEALED ISSUE.
09/13/96 9508020264 AB8 SKEEN D. Potential defective tap block, A88 part number 609224-001, 95184 for ABB type 51,87T relays, used for electronic protection in electrical switchgear. This part is a seven (7) position tap block located on the upper transformer printed circuit board. This part is used to change the relay's current settings. The tap block is designed to revert to the highest tap rating when the tap pin is removed. A small percentage (.0025) of these tap blocks were fourid to be defective from the ABB supplier. When the tap pin is removed the tap block will open circuit the transformer circuit. The transformer circuit is externally wired to the system current transformers. When the circuit transformers are open circuited a large voltage is possible, creating a hazard to the operator.
05/20/96 29263 05/23/ % ABB COM8USTION DENNIG R. PART 21 LOG #95198 - EN CONCERNING CONSUMERS POWER DISCOVERY 95198 OF AN ERROR IN THE WIRING OF RPS LOGIC THAT WOULD HAVE PREVENTED REACTOR TRIP ON VALID CONTAINMENT PRESSURE HIGH SIGNAL. CONDITION BELIEVED TO BE LIMITIED TO PALISADES.
05/20/96 0 05/23/ % ABB COMBUSTION DENNIG R. PART 21 LOG #95199 - REPORT CONCERNING CONSUMERS POWER 95199 DISCOVERY OF AN ERROR IN THE WIRING OF RPS LOGIC THAT WOULD HAVE PREVENTED REACTOR TRIP ON VALID CONTAINMENT PRESSURE HIGH SIGNAL. CONDITION BELIEVED TO BE LIMITIED TO PALISADES.
CLOSEOUT DOCUMENTED UNDER PART 21 LOG #95198.
05/06/96 29965 07/10/96 ABB COMBUSTION ENGINE HUNEMULLER N. PART 21 LOG #96350 - AB8 REPORTS A POTENTIAL DEFFECT 96350 GEN INVOLVING THE HIGH LOGARITHMIC POWER CHANNEL TRIP FUNCTION.
EN 29965 MENTIONS SAN ONOFRE AND WATERFORD AS AFFECTED.
TS-23 Page:2 otftyf97
PART 21 FOLLOW-UP AS$1GNMEDTS SORT > Plant Name QUERY >
ASSIGNMENT CLOSING PART21 EVENT DATE REPORT E D VENDOR ASSIGNED TO SUBJECT (Event Descriptiont NLegER TYPE 04/16/ % 0 05/21/ % ABB POWER SKEEN D. PART 21 LOG #96190 - ABB REPORTS POTENTIAL DEFECT OF A % 190 SUBCOMPONENT OF THE CVE-1 CLASS 1E ELECTROMECHANICAL RELAY.
THE POTENTIAL DEFECT RELATES TO THE DC "T" RELAY PSSIBLY OVERHEATING IN SERVICE. CORRECTIVE ACTION WAS TO UPGRADE THE RELAY. ALL PURCHASERS WERE NOTIFIED.
04/16/% 0 04/16/ % ABB POWER SKEEN D. PART 21 LOG #96191 - ABB PROVIDES A MINOR CORRECTION TO %191 NOTIFICATION DATED 1/25/%, PART 21 LOG #96190. CLOSE0UT OF ISSUE TO BE DOCUMENTED UNDER #96190.
OF/10/95 9507070477 11/01/95 ABB POWER T&D COMPANY SKEEN D. PART 21 LOG #95156 - NOTIFICATION OF A POTENTIAL DEFECT IN 95156 OTH CLASS 1E TYPE CVE-1 RELAY STYLE NUMBERS 1326D67A01 AND
...A02. THESE RELAYS HAVE TWO 110 VOLT RATED TELEPHONE RELAYS. SHOULD BE 120 VOLT TO HANDLE VOLTAGES IN TYPICAL SERVICE. COULD CAUSE RELAY TO OVERHEAT AND FAIL. NOTICE SENT TO ALL CUSTOMERS SHOWN IN RECORDS.
9507110099 05/13/96 ABB TURBO SYSTEM BENNER E. MODEL VTR 500 TURBO CHARGER; FATIGUE FAILURE OF COMPRESSION 95182 05/13/96 WHEEL.
09/16/95 0 08/17/95 ABB TURBO SYSTEMS BENNER E. EDG Turbo Charger failures. These turbo chargers were 95157 dedicated by the licensee and reported in EN 28997 & 29016.
The copy licensee letter is also filed under 95158. This problem is tracked for closure through EN 28997.
10/21/96 31178 11/12/ % ABB-CE HODGE V. ABB-CE RELOAD SAFETY ANALYSIS METHODOLOGY USES DEFECTIVE % 560 E01 CYCLE-SPECIFIC EVALUATION CRITERION TO VERIFY CONTINUED CONSERVATISM. AFFECTS SEVERAL PLANTS.
% 04300099 ABS-CE HODGE V. NOT A PART 21 REPORT: LICENSEE RESPONSE TO INSPECTION 96400 12/30/96 FINDING OF NONCONFORMANCE WITH PART 21 RE NEGATIVE PART 21 EVALUATIONS.
05/06/ % 9510110287 05/22/ % AEROFIN CARTER J. Part 21 #95-212 95212 GEN Product may utilize fastners with inadequate strength.
05/06/% % 02220425 05/16/% AEROFIN CARTER J. Part 21 #96-064 96064 Product may utilize fastners with inadequate strength.
Page:3 01f17f97 ETS-23
PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
PART21 EVENT ASSIGNMENV CLOSING DATE VENDOR AS$1GNED TO SUBJECT (Event DescriptiorO NUMBER TYPE DATE REPORT 0 11/08/95 AGC0 CARTER J. PART 21 LOG #95188 - CORRESPONDENCE FROM KEYSTONE SUBSIDIARY 95188 11/03/95 0F AGC0 PROVIDES TESTING RESULTS FOR AIR VS WATER CALIBRATION PROBLEM WITH MODEL 81P RELIEF VALVES. ISSUE CLOSED OUT UNDER EN 29066 (PART 21 #95163) USED INFO FROM THIS CORRESPONDENCE. NO FURTHER ACTION.
08/18/95 AGCO (SUS. OF KEYSTON CARTER J. PART 21 LOG #95163 - ANDERSON GREENWND (AGCO) REPORTS 95163 OTH 07/20/95 29066 POTENTIAL CLIBRATION PROBLEM FOR MODEL 81P RELIEF VALVES.
SHOULD BE CALIBRATED WITH FLUID, BUT MAY BE CALIBRATED WITH AIR IN THE FIELD DUE TO INAPPROPRIATE GUIDANCE IN ACCOMPANYING PROCEDURES. IN THE LATTER CASE MAY BE OFF BY 40% AT LOW SET PRESSURES (100 PSI). DUKE POWER HAS READJUSTED SOME VALVES USING THE AIR METHOD.
PART 21 LOG #951 4 - ANDERSON GREENWOOD (AGCO) REPORTS 95164 07/20/95 0 07/21/95 AGC0 (SUB. OF KEYSTON CARTER J.
POTENTIAL CLtBRATION PROBLEM FOR MODEL 81P RELIEF VALVES.
SHOULD BE CAllBRATED WITH FLUID, BUT MAY BE CALIBRATED WITH AIR IN THE FIELD DOE TO INAPPROPRIATE GUIDANCE IN ACCOMPANYING PROCEDURES. IN THE LATTER CASE MAY BE OFF BY 40% AT LOW SET PRESSURES (100 PSI). DUKE POWER HAS READJUSTED SOME VALVES USING THE AIR METHOD. THIS ITEM PROVIDES DETAILED FAX FROM AGCO. RELATED TO PART 21 LOG
PART 21 LOG #96270 - 50.72 VERSION OF A NOTIFICATION FROM 96270 04/92/96 30021 04/16/ % AMER INDUSTRIAL TECHN DENNIG R.
AMER INDUSTRIAL TECHNOLOGIES THAT THEY DID NOT APPROPRIATELY PERFORM COMMERCIAL DEDICATION FOR BECHTEL ON FILTER ELEMENTS PROCURED FROM NORMAN ULTRAPOROUS FILTERS FOR USE AT CALVERT CLIFFS AS PART OF THE CALVERT CLIFFS DIESEL GENERATOR PROJECT. RELATED TO PART 21 LOG #96271.
Page:4 01/17/97
- TS-23
. . ._ m. ... _ . . _ _ _ _ . -. .. . _m _ . . _ . - . .-_m _ _.m _. - . _ _ _ _ _ . . =- ._.m . ._. ... _.
PAR 7 21 FOLLOW-UP ASSIGNMEOTS SORT > Plant Name QUERY >
k CLOSING PART21 EVENT ASSIGNMECT MTJ REPORT DA,T1 VENDOR AS$1GNED TO SUBJECT (Event Description) NIAISER M 0 04/16/7 AMER INDUSTRIAL TECHN DENNIG R. PART 21 LOG #96271 - NOTIFICATION FROM AMER INDUSTRIAL 96271 04/12/96 TECHNOLOGIES THAT THEY DID NOT APPROPRIATELY PERFORM I
COMMERCIAL DEDICATION FOR BECHTEL ON FILTER ELEMENTS PROCURED FROM NGkMAN ULTRAPOROUS FILTERS FOR USE AT CALVERT CLIFFS AS PART OF THE CALVERT CLIFFS DIESEL GENERATOR PROJECT. RELATED TO PART 21 LOG #96270. THE REPORTS INDICATE NO ACTUAL DEFICIENCY OR FAILURE, NOR DO THEY PROVIDE ANY INFORMATION THAT SUPPORTS A CONCLUSION THAT ,
OTHER PLANTS WERE AFFECTED. NO FURTHER ACTION IS JUSTIFIED AT THIS TIME.
9508280137 05/13/% AMERACE SKEEN D. PART 21 183: AMERACE ELECTRONIC COMPONENTS, 95183 l 05/13/ %
MANUFACTURER OF E7000 SERIES RELAY TIMERS THAT ARE USED IN VAR'0US SAFETY-RELATED APPLICATIONS AT ALL 12 COMMONWEALTH EDISON NUCLER POWER PLANTS, REDUCED THE CONTACT RATING FOR THESE TIMERS. CONSEQUENTLY, SOME RELAYS MAY NOW BE MISAPPLIED.
05/13/ % AMERACE SKEEN D. AMERACE ELECTRONIC COMPONENTS, MANUFACTURER OF E7000 SERIES 95221 !
05/13/% 9510300253 RELAY TIMERS THAT ARE USED IN VARIOUS SAFETY-RELATED APPLICATIONS AT ALL 12 COMMONWEALTH EDISON NUCLEAR POWER PLANTS, REDUCED THE CONTACT RATING FOR THESE TIMERS.
CONSEQUENTLY, SOME RELAYS MAY NOW BE MISAPPLIED.
29906 03/04/% AMERACE (AGASTAT) SKEEN D. COMMONWEALTH EDISON REPORTS PROBLEMS WITH COLD SOLDER JOINTS % 180 E0!
12/07/95 IN A BATCH OF AGASTAT EGPDRC RELAYS IN EDG APPLICATIONS AT BYRON.
0 07/30/M AMERICAN INDUSTRIAL T DENNIG R. PART 21 LOG #96272 - AMERICAN INDUSTRIAL TECHNOLOGIES 96272 07/24/96 REPORTS THAT PART 21 ISSUE IS CLOSED BASED ON DEDICATION OF ;
OIL FILTER BY BG&E. >
9502020119 AMERSHAM NMSS Amersham drive cable dim 95092 NMS 02/29/ %
9505180270 AMERSHAM NMSS Harrisor' Amersham 680 retraction 95165 NMS r 02/29/96 9505180280 AMERSHAM NMSS Harrison Amersham 957 smoke 95166 NMS 02/29/ %
AMER $ HAM NMSS Amersham 899 drive cable connector 95137 ggs 02/29/ % 9509260253 i
i 9509130222 AMERSHAM NMSS 96010 NMS 02/27/ %
P Page:S 01/17/97-ITS-23
PART 21 FOLLOW-UP ASSIGNMECTS SORT > Plant Name QUERT>
PART21 EVENT ASSIGNMECT CLOSING g g VENDOR ASSIGNED TO SUBJECT (Event Description)
DATE REPORT DATE 29760 01/15/97 AMERSHAM NMSS LOOSE OR MISSING SCREWS IN MODEL 6608 RADIOGRAPHY CAMERA. %110 12/04/94 AMETEK/DIXON SKEEN D. PART 21 LOG #96360 - EN NOTIFICATION OF ISOLATED ANOMALY lu 96360 05/09/96 30312 PERFORMANCE OF BARGRAPH MODELS SA101P, SA202P, SN101P, AND SN202P. SOFTWARE PROBLEM WAS IDENTIFIED IN RARE OCCURRENCES IN COMMERCIAL APPLICATION ONLY, ALTHOUGH IN THEORY THE PROBLEM COULD AFFECT 1E SUPPLIED EQUIPMENT. ALL CUSTOMERS l NOTIFIED AND A CORRECTION WAS SEING DEVELOPED. ,
AMETEK/DIMSON SKEEN D. PART 21 LOG #96361 - NOTIFICATION OF ISOLATED ANOMALY IN 96361 05/09/96 30312 '
PERFORMANCE OF BARGRAPN MODELS SA101P, SA202P, SN101P, AND SN202P. SOFTWARE PROBLEM WAS IDENTIFIED IN RARE OCCURRENCES IN Co mERCIAL APPLICATION ONLY, ALTHOUGH IN THEORY THE PROBLEM COULD AFFECT 1E SUPPLIED EQUIPMENT. ALL CUSTOMERS JOTIFIED AND A CORRECTION WAS BEING L;EVELOPED. i I
0 ANCHOR DARLING GREENE T. QUAD CITIES WORKING WITH ANCHOR DARLING CONCLUDED THAT THE M100 T8D t 09/29/% CLEARANCES ON VALVES USED IN THE RHRSV STSTEM DID NOT HAVE :
ADEQUATE CLEARANCE TO 08VIATE GALLING AND EVENTUAL VALVE SEl2URE. QUAD CITIES LICENSEE STATES THAT VALVES WERE CUSTOM DESIGN FRO QAD CITIES AND NO OTHE PLANTS SHOULD BE AFFECTED.
i PART 21 LOG #95210 - HARRIS REPORTS THAT ANCHOR DARLING 2" 95210 i 29397 ANCHOR DARLING GREENE T.
05/20/96 CHECK GLOBE VALVES IN MINFLOW APPLICATION FOR CHARGING f SAFETY INJECTION PUMP DO NOT MEET FORWARD FLOW REQUIREMENTS [*
AND HAVE EXCESSIVE BACKLEAKAGE.
GREENE T. PART 21 LOG #95211 - HARRIS REPORTS THAT ANCHOR DARLING 2" 95211 I 05/20/96 9510060257 ANCHOR DARLING I
CHECK GLOBE VALVES IN MINFLOW APPLICATION FOR CHARGING SAFETY INJECTION PUMP DO NOT MEET FORWARD FLOW REQUIREMENTS ;
AND HAVE EXCESSIVE BACKLEAKAGE. i 28634 04/11/95 ARKANSAS NUCLEAR 1 KOSHY T. DRESSER VALVE REPORTS THAT AN ANO 1 STEAM SAFETY VALVE SENT 95115 OTN 04/05/95 TO THEM FOR REFURBISHMENT HAD PREVIOUSLY BEEN IMPROPERLY MODIFIED.
I 28593 04/14/95 ASCO SKEEN D. THIS PART 21 IS RELATED TO A CONDITION FOLLOWED UP IN ETS 95076 04/13/95 !
UNDER MR 3-95-0019 WHERE DETAILED INFORMATION CAN 8E FOUND.
I i
i Pege:6 01/17/97 ETS-23 I
PART 21 FOLLOW-UP ASSIGNMEOTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT LSSIGNMENT M REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) mygggg g 9506060227 08/21/95 ASCO SKEEN D. PART 21 LOG #95143 - CORRESPONDENCE PROVIDES ADDITIONAL 95143 07/13/95 INFORMATION ON PRESENCE OF NYOGEL IN A DISCONTINUED ASCO PRODUCT LINE. THE NP 8323 VALVES WERE USED AT LASALLE COUNTY ,
STATION ON MSIVs WHICH EXPERIENCED OPERATIONAL DIFFICULTIES.
CORRESPONDENCE STATES THAT IN THE VIEW OF ASCO THE NYOGEL WAS NOT THE CAUSE OF THE PROBLEM, AND THAT IN AGREEMENT WITH NRC STAFF THE PRESENCE OF THE NYOGEL DOES NOT CONSTITUTE A PART 21 REPORTABLE ISSUE. THl$ ISSUE IS BEING TRACKED UNDER t
EN 28573 AND RELATED PART 21 LOG #95076.
0 07/25/95 ASCO SKEEN D. PART 21 LOG #95080 - IN LER 440/94-023 DATED 1/11/95 PERRY 95080 0F/24/95 REPOR15 SLOW SCRAM TIMES DURING TESTING.
27504 08/18/95 ASCO SKEEN D. The description of this Part 21 report that is given in the 94178 OTH 08/09/95 old TOM dBase file is as follows: ;
AUTOMATIC SWITCH CO PROVIDES FURTHER INFO REGARDING SLOW SHIFTING PROBLEMS ON NP8342 SINGLE SOLENOID 4-WAY VALVES DUE TO DEGRADATION OF NYOGEL 775A LUBRICANT. SEE LOG #94177. l COOPER / TURKEY POINT REPORTED PROB. SEE LOG #94239 ALSO.
31229 PETRONE C. "6910-0XO" SOLEN 0ID PLUNGER WAS TOO SHORT CAUSING MSIV TO M750 GEN 10/29/% 12/05/96 AUTOMATIC VALVE / QUAD FAIL SURVEILLANCE TEST FOR CLOSING TIME. MANUFACTURER BLAMES A MISSED MACHINING STEP.
08/05/ % B&G MANUFACTURING CARTER J. PART 21 #96-065 96065 08/05/96 9605150136 9502030105 05/19/95 B&W KOSHY T. Non-conservative LOCA analysis that could raise peak clad 95087 05/16/95 tenperature through 50 F.
9508080129 07/29/ % B&W NUCLEAR TECHNOLOG CARTEit J. Part 21 #95-186 95186 GEN 05/06/ %
i THE NSss IDENTIFIES A CONCERN THAT MIGHT EXIST DURING RECOVERY FROM A SMALL BREAK LOCA. A REACTOR COOLANT " BUMP" i FOLLOWING MODERATOR DILUTION COULD CASE POST SBLOCA CRITICALITY. [
H-95-0038 03/28/95 BABCOCK & WILCox CO. BENNER E. B&W analysis indicating a change in peak clad tenperature of 95029 GEN b 03/24/95 50 F.
i Page:7 01/17/97 I TS-23
[
r
_ _ _ . . _ _ _ _ . . __.m___ _ _ _ _ _ _ . . _ _ _ . _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ . _ _ _ . _ _ . _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ -
. . _ _ _ . . - ~~ . -_ _ .. -.
S
- l i
PART 21 FOLLOW-UP ASSIGNMECTS SORT > Plant Name ,
QUERY >
PART21 EVENT r CLOSING ASSIGNMENT ASSTGNED TO SUBJECT (Event Deserlotion) ggga, g DE REPORT DATE VENDOR BARKSDALE/WATERFORD SKEEN D. PART 21 LOG #96690 - WATERFORD LICENSEE PFPORTS PROBLEM WITH 96690 08/16/96 9608010076 SARKSDALE PRESSURE SWITCH MODEL 01T-A150SS Fm CHASED AS QUAL CLASS 3 AND DEDICATED FOR USE ON ACCLBEULATORS. SWITCH WAS ,
CLASSIFIED AS PASSIVE SAFETY RELATED FOR MAINTAINING f PRESSURE INTEGRITY. 6 0F 7 FAILED ON TEST, WERE RETURNED TO BARKSDALE. ONE INSTALLED SHOWED NO SIGNS OF FAILURE. A NEW SWITCH IS BEING INSTALLED DUE TO OTHER CONCERNS (SEISMIC).
BARTON/SUfeqER TAPPERT J. PART 21 LOG #96700 - SUMMER LICENSEE REPORTS THAT THREE %700 08/16/ % 30811 BARTON MODEL 763 PRESSURE TRANSDUCERS FAILED SHORTLY AFTER BEING PLACED IN SERVICE DUE TO A LEAD TO THE STRAIN GAGE THAT BROKE LOOSE.
NMS NMSS ISSUE: CONTROL OF HIGH-DOSE RATE DEVICE. 96860 sutS 12/31/ % %12180245 01/15/97 BEAUMONT HOSPITAL NMSS I-125 SEED MISCALIBRATION. 96220 12/04/ % 9603050336 01/15/97 BEAUMONT HOSPITAL 26458 BEAVER VALLEY 2 BURTON W. Additional details on Butterfly valve failure. See 95152 GEN 08/14/95 Licensee's letter dated June 8, 1995. The problem was due to shaft spline adapter of the motor operator moved out of .'
position becoming separated from the drive sleeve.
BECHTEL POWER CORP. HODGE V. BALTIMORE GAS & ELECTRIC /CALVERT CLIFFS 1/2 PROVIDES UPDATE 95023 04/09/96 H-95-0032 REGARDING LONG-TERM COOLING PHASE OF LOCA WHICH DID NOT MODEL HEAT TRANSFER FROM RCS METAL. REANALYSIS TO BE PERFORMED. RESULTS EXPECTED TO NOT SIGNIFAFFECT PRIOR BASIS. SLE LOG #94310.
GREENE T. PART 21 #95110. CORRESPONDENCE FROM C&S VALVE ACKNOWLEDGING 95110 05/26/95 0 06/02/95 BETTis RECEIPT OF PART 21 INFO FROM BETTIS CORPORATION CONCERNING A SPRING PROBLEM WITH NHO 732-SR 80 ACTUATORS. THIS RELATES TO TROJAN WHO WAS THEIR CUSTOMER. C&S VALVE WAS UNABLE TO ASSESS SIGNIFICANCE OF SPRING DEFICIEhCY BUT INTENDED TO ,
FOLLOW UP WITH UTILITY AND BETTIS TO GET APPROPRIATE CORRECTIVE ACTION. THIS ITEM RELATES TO ASSIGNMENT TO T.
GREENE DATED 050295 AND TECHNICAL CLOSE00T WILL BE DOCUMENTED UNDER THAT ASSIGNMENT.
r t
Page:8 01/17/97 ITS-23
PART 21 FOLLOW-UP ASSIGNMENTS e
SORT > Plant Name QUERY >
PART21 EVENT
'iS$1GNMENT CLOSING D_A TJ, REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) NysgER M H-95-0099 BETTIS ACTUATORS AND GREENE T. A SPRING, P/N 013752, SUPPLIED BY COILING TECHNOLOGY IN THE 95093 05/02/95 1991-1992 TIMEFRAME FAILED M HIGH CYCLE (EVERY 5 MINUTES, 24 HOURS A DAY FOR TWO YEARS) COMMERCIAL APPLICATION. THIS SPRING IS PART OF BETTIS ACTUATOR MODEL NHD732- SR80. USE OF THIS SPRING DISCONTINUED IN 1992 AND STOCK PURGED.
9502220192 01/10/97 BOEING WANG E. OVER A NUMBER OF YEARS THE BOEING CORPORTATION HAS SUBMITTED 95078 GEN 04/13/95 NUMEROUS PART 21s RELATED TO VARIOUS BUGS IN CODES CALLED "ANSYS" AND "GTSTRUDL". THESE CODES ARE USED IN NUCLEAR PLANT APPLICATIONS. THE CURRENT BATCH OF NOTIFICATIONS ARE LOGGED AS PART 21 #95078, 95079, 95097, 95098, 95099, 95100, 95101, AND 95102.
9504180193 06/02/95 BOEING WANG E. PART 21 95-107. CORRESPONDENCE DESCRIBES A PROBLEM WITH 95107 05/26/95 COMPUTER CODE GT STRUDL THAT CAUSES PROGRAM TO ABORT. SINCE THIS FAILURE MODE DOES NOT INVOLVE ERRORS IN ANSWERS THAT MAY NOT BE OBVIOUS TO THE USER, IT DOES NOT PRESENT A POTENTIAL SAFETY CONCERN. NO FURTHER ACTION IS REQUIRED.
(NUMEROUS NOTICES FOR THIS PROGRAM MAVE BEEN RECEIVED )
PREVIOUSLY AND ARE BEING DISPOSITIONED ELSWHERE.)
9504260144 06/02/95 BOEING WANG E. PART 21 #95108. CORRESPONDENCE DESCRIBES TWO PROBLEMS WITH 95108 05/26/95 GT STRtOL THAT LEAD TO AN ABORT. SINCE THE PROBLEMS DO NOT INVOLVE INCORRECT ANWERS THAT MAY NOT BE OBVIOUS, NO SAFETY I
ISSUE IS INVOLVED. (OTHER REPORTS FROM BOEING ON THIS CCOE HAVE BEEN RECEIVED AND ARE BEING DISPOSITIONED ELSEWHERE).
t WANG E. PART 21 95109. CORRESPONDENCE TRANSMITS ONE ERROR WITH GT 95109 I 05/26/95 9505050145 06/02/95 BOEING STRLOL THAT CAUSES AN ABORT AND IS THUS NOT A SAFETY ISSUE, ,
AND SEVERAL PROBLEMS WITH THE ANSYS CODE WHERE THE IMPACT OF THE ERROR IS IMPOSSIBLE TO JUDGE EXCEPT BY THE USER OF THE CODE. THE TOPIC OF GT STRUDL AND ANSYS PROBLEMS THAT MAY t CAUSE ERRORS IN RESULTS THAT ARE NOT OBVIOUS IS BEING DISPOSITIONED UNDER TAC #M91542 AND AN ETS ENTRY DATED [
4/13/95.
1 9505110227 06/30/95 BOEING DENNIG R. BOEING COMPUTER SERVICES FORWARDS A PROBLEM REPORT FROM 95128 ,
06/30/95 GEORGIA TECH RE: GTSTRUDL. THE PARTICULAR PROBLEM CAUSES THE i PROGRAM TO ABORT.
t Page:9 01/17/97 15-23
- _ - _ _ - . - - - _ - _ _ . . . _ _ _ _ _ _ . _ . _ - _ - . - - _ . - _ . _ - - - - - - - _ - - _ _ . _ . - _ - _ . _ _ - _ _ - . _ _ . _ . - - . - - _ - _ - _ _ . - - - - _ - - - . - - - . - - . _ _ . - . - - _ _ _ _ _ - _ _ - - - - - - - . - - _ _ - - - - _ - . _ _ _ - - - - _ . _ . _ _ _ _ - . - . . = _ _ _ - - - _ . - _ _ - . _ - - - _ _ . . - - . - - . _ - . - . . - _ _
I 3 PART 21 FOLLOW-UP CSSIGNMECTS SORT > Flant Name QUERY >
PART21 EVENT LSSIGNMEN7 CLOSING Og REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) ggggR, R g WANG E. PART 21 LOG #95135 - BOEING REPORTS RECEIPT OF INFORMATION 95135 07/10/95 9505190154 07/18/95 BOEING DEALING WITH ANSYS PROBLEMS. THIS CORRESPONDENCE ALSO CONTAINS A LISTING OF ANSYS PROBLEMS OVER A PERIOD OF TIME.
IT IS NOT POSSIBLE TO DETERMINE THE SAFETY IMPACT OF ANY OF THE DESCRIBED ERRORS. A GENERIC SOLUTION TO PART 21 PROSLEMS OF THIS NATURE IS BEING PREPARED.
WANG E. PART 21 LOG #95136 - BOEING REPORTS RECEIPT OF INFORMATION 95136 OF/10/95 9505250206 07/18/95 BOEING DEALING WITH ANSYS PROBLEMS. IT IS NOT POSSIBLE TO DETERMINE THE SAFETY IMPACT OF ANY OF THE DESCRIBED ERRORS. A GENERIC SOLUTION TO PART 21 PROBLEMS OF THIS NATURE IS BEING PREPARED.
WANG E. PART 21 LOG #95145 - CORRESPONDENCE FORWARDS ANSTS AND 95145 OF/14/95 0506130013 07/18/95 BOEING ,
GTSTRUDL PROGRAM PROBLEM NOTIFICATIONS. NOT POSSIBLE TO DETERMINE SAFETY SIGNIFICANCE, IF ANY. THIS TOPIC WILL BE RESOLVED USING A GENERIC APPROACH. (BGCTS95-072) 07/18/95 BOEING WANG E. PART 21 LOG #95146 - CORRESPONDENCE FORWARDS GTSTRUDL 95146 0F/14/95 9506140411 PROGRAM PROBLEM NOTIFICATIONS. NOT POSSIBLE TO DETERMINE SAFETY SIGNIFICANCE, IF ANY. THIS TOPIC WILL BE RESOLVED USING A GENERIC APPROACM. (BGCTS95-072) 08/22/95 BOEING WANG E. PART 21 LOG #05168 - VARIOUS ANSYS AND GTSTRUDL ERROR 95168 08/07/95 9507120216 NOTIFICATIONS.
02/14/96 BOEING WANG E. PART 21 LOG #95179 - BOEING FORWARDS SEVERAL ERROR 95179 08/25/95 9508090166 NOTIFICATIONS FOR ANSYS. NUMEROUS PREVIOUS ASSIGNMENT MADE UNDER BGCTS95-072. CLOSEOUT DOCUMENTED UNDER ORIGINAL ASSIGNMENT.
02/14/96 BOEING WANG E. 95097 02/14/ % 9503060315 9502240156 02/14/96 BOEING WANG E. 95098 02/94/%
02/14/96 BOEING WANG E. 95099 02/14/ % 9502220192 9502010239 02/14/ % BOEING WANG E. 95100 02/14/ %
02/14/96 BOEING WANG E. 95101 02/14/ % 9503130066 Pa9e:10 otf t yf97 TS-23
, _ _ ._ _ . . ~ . . _ _ _ . . _ .__.m m _ .._ _.
5 I
PART 21 FOLLOW-UP CSSIGNMENTS SCRT> Plant Name QUERY >
CLOSING PART21 EVENT
.AS$1GNMEOT DE REPORT E D VENDOR ASSIGNED TO SUBJECT (Event Description) NypWER M 9503280210 02/14/96 BOEING WANG E. 95102 02/14/ %
r 9508::90238 05/13/ % BOEING WANG E. PART 21 #95191 - CORRESPONDENCE DESCRIBES ANOTHER GLITCH IN 95191 05/13/96 ANSYS. l 9509070043 05/13/ % BOEING WANG E. PART 21 #95192 - CORRESPONDENCE DESCRIBES ANOTHER GLITCH IN 95192 05/13/ % 1 ANSYS.
05/13/ % BOEING WANG E. PART 21 #95205 - CORRESPONDENCE DESCRIBES ANOTHER GLITCH IN 95205 05/13/M 9509210296 ANSYS.
05/13/ % BOEING WANG E. PART 21 #95216 - CORRESPONDENCE DESCRIBES ANOTHER GLITCH IN 95216 05/93/M 9510250397 ANSYS.
9510270234 05/13/ % BOEING WANG E. PART 21 #95218 - CORRESPONDENCE DESCRIBES ANOTHER GLITCH IN 95218 05/13/ %
ANSYS. THIS TOPIC 15 BEING TREATED GENERICALLY VIA BGCTS95-072, TAC #M91542 AND WILL BE REVIEWED AS PART OF THAT EFFORT. l ALSO SEE PART 21 #95078.
H-95-0020 01/31/95 BOEING COMPUTER SERVI GOODWIN E. ERRORS IN ANSYS 95015 OTH !
01/26/95 9501310290 05/05/95 BOEING COMPUTER SERVI WANG E. CORRESPONDENCE DESCRIBES ANOTHER GLITCM IN ANSYS. 95091 05/02/95 9511130319 BOEING COMPUTER SERVI DENNIG R. NOT A NEW ISSUE BUT A NEW ISSUE NUMBER. SOFTWARE ERROR IN 96200 12/30/96 t THE GTSTRUDL MODE -- HARMONIC M ALYSIS ERROR- h 9603120351 BOEING COMPUTER SERVI DENNIG R. NOT A NEW ISSUE BUT A NEW ISSUE NUMBER: SOFTWARE ERROR IN 96230 t 12/30/ %
THE ANSYS -- INCORRECT PRIN"IPLE STRAINS.
L 9607150301 BOE!NG COMPUTER SERVI DENNIG R. NOT A NEW ISSUE BUT A NEW ISSUE NUMBER. SOFTWARE ERROR IN 96640 12/04/96 THE ANSTS CODE -- DAMPING IGNORED UNDER CERTAIN CONDITIONS. i N-95-0035 01/30/95 BORG-WARNER CORP. DENNIG R. BORG WARNER PROVIDES A LISTING OF AFFECTED LICENSEE. THIS 95026 01/30/95 IS A FOLLOWUP TO A PRIOR ASSIGNMENT OF #94278 To EMEB/KHANNA.
I Page:11 otfj7fg7 ,
TS-23
- I
, e, CART 21 FOLLOW-UP ASSIGNMECTS SORT > Plant Name QUERY > !
CLOSING PART21 EVENT ASSIGNMEOT DATE REPORT E VENDOR AS$1GNED TO SUBJECT (Event Description) g g H-95-0034 BORG-WARNER CORP. HODGE V. BW/IP INTERNATIONAL PROVIDES LISTING OF POTENTIALLY AFFECTED 95025 04/08/ %
LICENSEES REGARDING NONCONSERVATIVE FRICTION FACTORS FOR BORG-WARNER GATE VALVES. SEE LOG #94-127 01/05/95 BRAIDWOOD 2 K0ENICK S. MANUFACTURING DEFECT CAUSES FAILURE OF EDG CONNECTING ROD. 95048 E01 {
11/08/94 H-95-0059 .
0 01/17/96 BRAIDWOOD 1,2 SKEEN D. Part 21 95-181 95181 OTH 12/20/95 Amerece Electronic Components, manufacturer of E7000 Series Relay Timers that are used in various safety-related applications at all 12 Cominonwealth Edison nuclear power
- plants, reduced the contact rating for these timers.
Consequently, some relays may now be misapplied.
H-95-0081 03/27/95 BROWN BOVERI ELECTRIC KOSHY T. Falture of 27N (mdervoltage relay) manufactured by Asea 95061 03/28/95 Brown Boveri was identified to be not reportable under part :
21 based on further review. I i
WANG E. 95081 OTH 05/02/95 0 05/03/95 BW/IP INTERNATIONAL 05/04/95 BW/IP INTERNATIONAL, WANG E. A RELAY INSTALLED IN AN ELECTRO-HYDRAULIC ROTARY DAMPER 95081 GEN [
04/14/95 28603 '
ACTUATOR WAS INCORRECTLY CERTIFIED. THE VENDOR STATED THAT THE PART WAS STILL CAPABLE OF PERFORNING THE REQUIRED FUNCTION.
I BYRON 2 HODGE V. PT21 #95-067 95067 [
05/20/96 23774 i
ERROR IN BORON DILUTION ANALYSIS IN SAFETY ANALYSIS REPORT.
29853 BYRON 1,2 HODGE V. Limitorque MOV, supplied by Westinghouse, motor pinion gear % 170 12/30/96 falted.
C5D CHARTER POWER SYSTEMS REPORTS THAT WELDS ON THE WELD NUT 96000 ;
12/10/96 31471 C&D CHARTER POWER SYS SKEEN D.
HOLDING THE FILTER ASSEMBLY PANEL WERE NOT TO SPEC AND COULD FAIL UNDER SEISMIC LOADS. PS&G AND NORTHERN STATES WERE AFFECTED AND TO BE INFORMED BY C&D.
Page:12 01/17/97 ITS-23
PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT 4SSIGNMEDV E
D REPORT DE g ASSIGNED TO SUBJECT (Event Description) g g 0 12/02/96 CALVERT CLIFFS 1,2 SKEEN D. LICENSEE REPORTED TWO FAILURES OF GE TYPE AMM-4.76-250 MAGNE 96770 GEN 11/10/M BLAST 3REAKERS TO CLOSE DURING TESTING. INVESTIGATION FOUIC THAT THE MANUAL TRIP LEVER WAS BENT ON ONE BREAKER AND THE "L" BRACKET SUPPORT FOR THE TRIP LEVER WAS BROKEN ON THE OTHER BREAKER.
29328 05/22/ % CANADIAN WORCESTER CO CARTER J. Part 21 #95-203 95203 GEN 05/06/96 Bett valves utilize presssure retaining festners that may not be acceptable.
9509200375 05/16/ % CANADIAN WORCESTER CO CARTER J. Part 21 #95-206 95204 05/06/ %
Batt valves utilize presssure retaining festners that may not be acceptable.
29916 05/16/ % CANADIAN WORCESTER CO CARTER J. Part 21 #96-062 96062 05/06/ %
Batt valves utilize presssure retaining fastners that may not be acceptable.
05/06/ % 9602060071 05/16/ % CANADIAN WORCESTER CO CARTER J. Part 21 %-063 96063 Batt valves utilize presssure retaining festners that may not be acceptable.
29257 05/22/ % CARDINAL INDUSTRIAL P CARTER J. Part 21 #95-1% 951 % GEN 05/06/ %
Some fasteners (capscrews) had an inproper heat treatment and as a result may not have the proper strength. j i
9509080175 05/16/ % CARDINAL INDUSTRIAL P CARTER J. Part 21 #95-197 95197 05/06/96 t
Some fasteners (capscrews) had an inproper heat treatment and as a result may not have the proper strength. !
f 9509210006 05/16/96 CARDINAL INDUSTRIAL P CARTER J. Part 21 #95-200 95200 05/06/ % ,
i Some f asteners (capscrews) had an inproper heat treatment I and as a result may not have the proper strength.
t i
Page:13 01/17/97 TS-23 I
PART 21 FOLLOW-UP ASSIGNMENTS i SORT > Plant Name QUERY >
)
CLOSING PART21 EVENT l
%SSIGNMEOT E
D REPORT E D VfMDOR ASSIGNED TO SUBJECT (Event Description) g g 05/06/96 9509210008 05/16/96 CARolNAL INDUSTRIAL P CARTER J. Part 21 895-201 95201 Some fasteners (capscrews) had an improper heat treatment f and as a result may not have the proper strength.
05/06/96 9510160200 05/16/96 CARDINAL INDUSTRIAL P CARTER J. Part 21 #95-207 95207 Some fasteners (capscrews) had an improper heat treatment and as a result may not have the proper strength.
05/06/ % 9511270144 05/22/ % CARDINAL INDUSTRIAL P CARTER J. Part 21 #96-060 96060 Some f asteners (capscrews) had an improper heat treatment t and as a result may not have the proper strength.
9511270151 05/16/96 CARDINAL INDUSTRIAL P CARTER J. Part 21 896-061 96061 I 05/06/ %
some fasteners (capscrews) had an inproper heat treatmes.c and as a result may not have the proper strength.
27924 01/12/95 CATAWBA WEN P. MATERIAL FAILURES IMPACTING OPERABILITY OF St PUMPS. 95010 OTH 10/20/94 12/19/% 31477 CLINTON 1 CARTER J. CLINTON REPORTS THAT TORQUE VALUES SPECIFIED BY GE WERE 96 TBD ,
INCORRECT FOR THE 3/8TH INCH HOLD DOWN 80LTS ON THE HCU l FIXTURES. TORQUE EXCEEDED MINIMUM YIELD STRESS FOR MATERIAL ,
AND COULD FAIL UNDER SEISMIC CONDITIONS.
08/08/96 30775 11/29/96 CLOW/NINE MILE POINT HUNEML'lLER N. PART 21 LOG #96660 - NIAGARA MOHAWK REPORTS DOWEL PIN NOT 96660 OTH PEENED IN PLACE FELL OUT AND WOULD PREVENT S8GTS LOGIC FROM FUNCTIONING ON THE AFFECTED TRAIN. VALVE MANUFACTL* RED BY CLOW.
02/06/95 H-95-0049 02/13/95 COLT INDUSTRIES DENNIG R. DOCUMENTATION FROM COLTEC THAT ISSUE REPORTED TO THEM 8Y 95040 SCE&G DOES NOT MEET PART 21 THRESHOLD.
02/17/95 H-95-0054 04/07/95 COLT INDUSTRIES WANG E. COLTEC INDUSTRIES RECEIVED A REPORT FROM PECO CONCERNING 95044 OTH ABNORMAL WEAR AND PITTING OF A LUBE OIL DRIVE BRACKET.
COLTEC IS INVESTIGATING, AND POWER STATIONS WITH FMED 81/8 ,
OPPOSED PISTON EDG SETS COULD BE AFFECTED. FINAL REPORT PROMISED.
Page:14 otfi7f97 TS-23 E
PART 21 FOLLOW-UP CSSIGNMECTS SORT > Plant Name QUERY >
PART21 EVENT CLOSING AS$1GNMENT E AS$1GNED TO SUBJECT (Event Description) NLyggR g DE REPORT D VENDOR 03/23/95 COLT INDUSTRIES KOSHY T. EARLY FAILURE OF LUBE OIL Pt.MP GEAT DUE TO MISALIGNMENT. 95063 OTN 03/21/95 H-95-0078 04/13/95 COLT INDUSTRIES DENN!G R. COLTEC PROBLEM WITH MISALIGNMENT OF LUBE OIL DRIVE CAUSING 95069 04/12/95 9502240086 ACCELERATED WEAR ON GEER TEETH ON CERTAIN MODELS OF EMERGENCY DIESEL GENERATOR.
H-95-0025 COLT INDUSTRIES HODGE V. COLTEC INDUSTRIES /FMED PROVIDES FINAL ENGG REPORT ON 95020 04/09/96 CRACKING OF AIR START DISTRIBUTOR CAMS AT NORTH ANNA & ANO.
ROOT CAUSE/CORREC ACTIONS IDENTIFIED. AFFECTED LICENSEES NOTIFIED. SEE LOG #94067 AND 94004.
26758 08/21/95 COLTEC WANG E. The description of the lead Part 21 report given in the old 94070 OTH 08/14/95 TQM dBase file is: 94070 F - SOUTH CAROLINA E&G/ SUMMER 1 REPORTS LEVEL SWITCHES FOR EDG DAY TANKS MAY NOT BE SEISMICALLY QUALIFIED. COLTEC/FMED PROVIDED SWITCHES AS SIESMIC QUAL., BUT CANNOT PRODUCE DOCUMENTATION. SEE LOG
- 94302/95040.
Additional related Part 21 reports are described in the closeout section below.
0 COLTEC/ LIMERICK TAPPERT J. PART 21 #96590 - MEMO REGION I TO HAASS 10/23/ % TRANSMITS %590 GEN 19/12/96 LETTER FROM PECO (LIMERICK) TO COLTEC RE: UNDERSIZED EDG LUBE OIL HEAT EXCHANGER. LETTER REQUESTS PART 21 REVIEW FROM COLTEC.
0 04/26/ % COMANCHE PEAK 1,2 DENNIG R. PART 21 LOG #96240 - LICENSEE REPORTS SCRATCHES ON AS- 96240 04/22/96 RECEIVED FAN MOTOR BEARINGS MANUFACTURED BY FAFNIR. BEARINGS TO BE USED AS REPLACEMENTS ON UPS ROOM FAN COIL UNITS SUPPLIED BY ELLIS AND WATTS. THIS IS AN INTERIM REPORT, WITH A FINAL REPORT PROMISED BY 2/29/%. NO FINDING OF SUBSTANTIAL SAFETY HAZARD AT THIS TIME.
0 04/26/96 COMANCHE PEAK 1,2 DENNIG R. PART 21 LOG #96241 - LICENSEE REPORTS THAT FURTHER 96241 04/22/96 INVESTIGATION OF THE IMPACT OF THE INDICATIONS ON SPARE BEARINGS (MANUFACTURED BY FAFNIR) FOR FCUs LED TO THE CONCLUSION THAT A SUBSTANTIAL SAFETY HAZARD DID NOT EXIST AND THAT NO PART 21 REPORT WAS REQUIRED.
Page:15 01/17f97 ETS-23
---.- .a._~-.._-....-, ---.- -~~ ---. ~., . ~ . _ ~ . - _ . _. . . . , _
PART 21 FOLLOW-UP ASSIGNMEO75 SORT > Plant Name QUERY >
t CLOSING PART21 EVENT ,
ASSIGNMEOT REPORT DATE VENDOR AS$1GNED TO SUBJECT (Event Description) g g EATJ 30653 07/30/96 COOK 2 DENNIG R. PART 21 LOG #96600 - COOK LICENSEE (AMERICAN ELECTRIC POWER 96600
' 0F/24/%
REPORTS THAT TWO SPRINGS FAILED IN SERVICE ON ONE OF THE EDGs DURING TROUBLESHOOTING FOR A SPEED CONTROL PROBLEM. j t
OTHER SPRINGS ENAMINED WITH NO EVIDENT DEFECTS. NO OTHER FAILURES. ONLY WORTHINGTON DIESELS IN NUCLEAR SERVICE. NO FURTHER ACTION.
30653 07/30/ % COOK 2 DENNIG R. PART 21 LOG #96601 - COOK LICENSEE (AMERICAN ELECTRIC POWER 96601 OF/24/%
REPORTS THAT TWO SPRINGS FAILED IN SERVICE ON ONE OF THE EDGs DURING TROUBLESHOOTING FOR A SPEED CONTROL PROBLEM. 4 OTHER SPRINGS EXAMINED WITH NO EVIDENT DEFECTS. NO OTHER FAILURES. ONLY WORTHINGTON DIESELS IN NUCLEAR SERVICE. NO FURTHER ACTION.
4-95-0014 05/18/95 COOPER 1 GREENE T. DURING A PLANT SHUTDOWN, AN MOV FAILED TO OPERATE BECAUSE A 95050 E01 02/15/95 STEM CAP HAD THREADED ITSELF INTO THE MOV CASING, PREVENTING THE STEM NUT FROM MOVING. THIS CAUSED THE MOTOR TO DEENERGIZE DUE TO OVERLOADING. FURTHER REVIEW IDENTIFIED '
THREE OTHER VALVES HAD POTENTIAL TO FAIL DUE TO THE SAME PROBLEM. LICENSEE INDICATED THAT THEY HAD REPLACED THE STEM !
CAPS AND FIALED TO STAKE THEM TO PREVENT MOVEMENT.
28366 02/22/95 COOPER 1 KOSHY T. SUSPECTED GENERIC PROBLEMS WITH TARGET ROCK ADS RELIEF 95049 OTH 02/21/95 '
VALVES.
i 4-95-0014 03/28/95 COOPER 1 HUNEMULLER N. Vectam breaker not fully shut because of over size and right 95051 OTH 02/21/95 [
angled face.
i WAhG E. PART 21 LOG #95147 - COOPER ENERGY SERVICES ADylSES THAT 95147 OTH 06/1G/95 28951 10/30/95 COOPER 1 GRAND GULF EXPERIENCED A FAILURE OF A BELLOFRAM AIR CYLINDER l THAT RESULTED IN IMPACT ON EDG INTAKE AIR. DIESEL HAD TO BE SHUT DOWN. FAILURE OCCURRED IN PROJECTION WELD IN THE PISTON / PISTON ROD ASSEMBLY. THE ROOT CAUSE WAS DETERMINED TO BE POOR QUALITY OF THE WELD. NO OTHER KNOWN FAILURES (ALL COOPER EDGs AFFECTED). COOPER CONCLLBES ISOLATED INCIDENT, ALL CUSTOMERS NOTIFIED.
' I H-95-0037 01/30/95 COOPER ENERGY SERVICE DEMNIG R. COOPER ENERGY SERVICES PROVIDES AD0'L INFO RE LOCATION OF 95028 01/30/95 SUSPECT MASTER CONNECTING RCX)S. PRIOR ASSIGNMENT #94296. .
i Page:16 01/17/97 EVS-23 i
- . _ _ _ _ _ _ _ _ _ . _ _ _ . _ _ _ _ . . _ _ _ _ . _ _ .__,_.__.__m m_m __m__ m___ _ _ _ _ _ _ _ _ . _ _ _ _ _ . ___ _ _ _ . _ _ _ _ _ . _ _ _ _ . _ _ _ - . . _ _ _ . m._______m_________ _ _ _ _ . _ _ _ _ _ . _ _ _ _ _ _ _
i PCRT 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT CSSIGNMEOT ASSIGNED TO SUBJECT (Event Description) EMEE M M REPORT DATE VENDOR 28710 06/08/95 COOPER ENERGY SERVICE CARTER J. THIS ITEM (EN#28710) DEALS WITH A CONDITION RESULTING IN 95116 06/07/95 INADEQUATE FLod CF COOLING WATER TO THE MECHANICAL GOVERNOR OF EMERGENCY DIESEL GENERATORS. THIS WAS THE RESULT OF A DESIGN DEFICIENCY IN THE COOLING SYSTEM SUPPLIED BY COOPER ENERGY SERVICES FOR THE DIESELS AT NINE MILE POINT UNIT 2 AND THE BYRON UNITS.
0 06/08/95 CCOPER ENERGY SERVICE CARTER J. THIS ITEM IS A REPORT FROM COOPER INDUSTRIES (COOPER- 95117 06/07/95 BESSEMER) DEALS WITH A CONDITION RESULTING IN INADEQUATE FLOW OF COOLING WATER TO THE MECHANICAL GOVERNOR OF EMERGENCY DIESEL GENERATORS. THIS WAS THE RESULT OF A DESIGN DEFICIENCY IN THE COOLING SYSTEM SUPPLIED BY COOPER ENERGY SERVICES FOR THE DIESELS AT NINE MILE PolNT UNIT 2 AND THE BYRON UNITS.
30520 COOPER ENERGY SERVICE GREENE T. PART 21 LOG #96450 - COOPER ENERGY SERVICES REPORTS THAT THE 96450 06/10/96 KSV EMERGENCY DIESEL GENERATOR SYSTEM MAY HAVE A DEFECT INVOLVING THE FUEL INJECTION PUMP DELIVERY VALVE HOLDER. THE DEFECT IS THE DEVELOPMENT OF CRACKS THAT COMPROMISE THE INTEGRITY OF THE HOLDER. NINE MILE 2, PALO VERDE, ZION 2, AND SUSQUEHANNA MAVE OBSERVED THE PROBLEM.
9605240250 COOPER ENERGY SERVICE GREENE T. PART 21 LOG #96451 - COOPER ENERGY SERVICES REPORTS THAT THE 96451 06/10/96 KSV EMERGENCY DIESEL GENERATOR SYSTEM MAY HAVE A DEFECT INVOLVING THE FUEL INJECTION PUMP DELIVERY VALVE HOLDER. THE DEFECT IS THE DEVELOPMENT OF CRACKS THAT COMPROMISE THE INTEGRITY OF THE HOLDER. NINE MILE 2, PALD VERDE, ZION 2, AND SUSQUEHANNA HAVE OBSERVED THE PROBLEM.
l I
Page:17 01/17/97 ETS-23
PART 21 FOLLOW-UP ASSIGNMEDTS SORT > Plant Narne QUERY >
AS$1GNMECT CLOSING PART21 EVENT DATE REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Descriction) g g 09/16/ % 30728 COOPER ENERGY SERVICE TAPPERT J. STARTING AIR ADMISSION VALVES (SLOCK AND VENT VALVES), 96610 ENTERPRISE PART NO. KR-001-000, ORIGINALLY MANUFACTURED BY CALCON CORP. (CALCON HAS SINCE BEEN PURCHASED BY AMOT CONTROLS CORP.) ARE PART OF REDUNDANT STARTING CIRCUITS SUCH THAT TWO ARE EMPLOYED ON MODEL DSR-4 AND FOUR ON MODEL DSRV-
- 4. THE POTENTIAL DEFECT WAS REPORTED TO CES BY ENTERGY OPERATIONS AFTER THREE VALVES AT RIVER 8END FAILED DURING OPERATION OR WHILE ON THE TEST BENCH. FAILURE OF THESE VALVES COULD RENDER THE EDG IMOPERA8LE; CAUSE MAS NOT BEEN DETERMINED. THE FOLLOWING NINE U.S. SITES ARE AFFECTED:
HARRIS, PERRY, CATAWBA, GRAND GULF, RIVER BEND, V0GTLE, COMANCHE PEAK, BELLEFONTE AND WNP-1. SEVERAL SITES IN KOREA .
AND TAlWAN MAY ALSO BE AFFECTED.
12/30/ % 29653 COOPER ENERGY SERVICE TAPPERT J. EDG GOVERNOR DRIVE ASSEMBLY OIL HOLE 8 LOCKED. 96070 06/0F/95 9505010161 06/08/95 COOPER INDUSTRIES CARTER J. THIS ITEM IS A REPORT FROM COOPER INDUSTRIES (COOPER- 95119 BESSEMER) DEALS WITH A CONDITION RESULTING IN INADEQUATE FLOW OF COOLING WATER TO THE MECHANICAL GOVERNOR OF EMERGENCY DIESEL GENERATORS. THIS WAS THE RESULT OF A DESIGN DEFICIENCY IN THE COOLING SYSTEM SUPPLIED BY COOPER ENERGY SERVICES FOR THE DIESELS AT NINE MILE POINT UNIT 2 AND THE BYRON UNITS.
06/0F/95 9504260118 06/08/95 COOPER INDUSTRIES CARTER J. THIS ITEM IS A REPORT FROM COOPER INDUSTRIES (COOPER- 95118 BESSEMER) DEALS WITH A CONDITION RESULTING IN INADEQUATE FLOW OF COOLING WATER TO THE MECHANICAL GOVERNOR OF ,
EMERGENCY DIESEL GENERATORS. THIS WAS THE RESULT OF A DESIGN DEFICIENCY IN THE COOLING SYSTEM SUPPLIED BY COOPER ENERGY SERVICES FOR THE DIESELS AT NINE MILE POINT UNIT 2 AND THE BYRON UNITS.
04/06/95 1-95-0014 04/07/95 COPES-VULCAN INC. KOSHY T. Diaphram problem prevented futt opening of PORVs at Haddam 95038 Neck.
ETS-23 Page:18 01/17/97
S
- PART 21 FOLLOW-UP ASSIGNMECTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT ASSIGNMECT DATE REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) N(mggg g 9412010115 02/06/95 COPES-VULCAN. INC. DENNIG R. COPES VULCAN REPORTED THAT AN ERROR IN MANUFACTURlWG 95032 02/01/95 RESULTED IN UNACCEPTABLE THREAD FORM. THE PROBLEM IS THAT YOKES WITH THIS PROBLEM WON'T HOLD ATTACHMENTS PROPERLY BECAUSE THEY LACK THE STRENGTH TO TAKE THE REQUIRED TORQUE OF THE FASTENER BEING USED. 9 YOKES AT TVA, 1 AT FARLEY, 1 AT POINT BEACH WERE AFFECTED. YOKES WILL BE REPLACED. NATURE OF THE ERROR WAS SELECTION OF THE WRONG TOOL FOR FORMING THE THREADS (CUT AATHER THAN FORMED.)
H-95-0009 08/16/% CRANE-ALOYC0 HUNEMULLER N. CRANE VALVES / NUCLEAR OPERATIONS REPORTS FAILURE OF 10" VALVE 95006 OTH 01/23/95 (FIGURE 63174) AT WELD JOINING YOKE AND ADAPTER PLATE AND MORE CATASTROPHIC FAILURE TO OTHER PARTS DUE TO INCLUSION OF SHIMS CONTRARY TO DRAWING. PART OF ORDER FOR WESTINGHOUSE IN EARLY 70s.
H-95-0033 01/30/95 CRANE-ALOYC0 DENNIG R. CRANE VALVE PROVIDES FINAL REPORT ON REQUIRED THRUST. THIS 95024 01/30/95 IS FOLLOWUP REPORT TO #94150 PREVIOUSLY AS$1GNED TO EMEB/ SCAR 8 ROUGH.
H-95-0044 02/01/95 CRANE-ALOYC0 GOODWIN E. CRANE VLV YOKE FAILURES 95035 02/01/95 H-95-0006 11/15/96 CRANE-ALOYC0 HODGE V. CRANE VALVES PROVIDES UPDATE ON CONTINUING EFFORTS TO 95005 l 04/0G/96 EVALUATE WHETHER ERRONEOUS DATA TO SET TORQUE SWITCHES FOR MOVs WAS SUPPLIED TO LICENSEES DURING MID-1980S. NO CONTRACTURAL EVIDENCE FOUND YET. SEE LOG #94150/95007 ET AL.
0 CRAWFORD FITTING GREENE T. PART 21 LOG #96280 - CRAWFORD FITTING REPORTS POSSIBLE 96280 04/15/96 MATERIAL DEFECT IN CERTAIN SWAGELOK FITTINGS MADE FROM STAINLESS STEEL FORGINGS. THE MATERIAL DEFECT IS IN THE FORM OF EXOGENOUS SOURCE CONTAMINATION THAT CAUSES A MATERIAL WEAKNESS TO FORM DURING THE FORGING PROCESS. ALL PURCHASERS HAVE BEEN NOTIFIED. <
0 CRAWFORD FITTING GREENE T. PART 21 LOG #96281 - CRAWFORD FITTING PROVIDES FURTHER 96281 05/06/96 INFORMATION ON AFFECTED CUSTOMERS W.R.T. A POSSIBLE MATERIAL DEFECT IN CERTAIN SWAGELOCK TUBE FITTINGS. CUSTOMERS NOTIFIED.
Page:19 01/17/97 ETS-23 l
i
_ __.____________.___.._.______________________.__._m____m___ _ _ _ _ _ _ _ _ . _ _.__m __. _ _ _ _ . . _ _ _ _ _ . _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _____._______
PAR 7 21 FOLLOW-UP CSSIGNMEOTS SORT > Plant Name OUERD CLOSING PART21 EVENT ASSIGNMENT DATE REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) g g 02/24/95 H-95-0066 04/27/95 CRAWFORD FITTINGS KIRKPATRICK D. See letter from Swagelok ( Crawford Fitting Company) 95055 OTN addressing materlat defect in stainless steel fitting or adapters. Heat ON GNM. They have identified only one yet.
Fittings in question are 1/8",1/4" and 3/8" H-95-0012 CRYSTAL RIVER 3 KOSHY T. MOV BRAKES LOCK ON DEGRADED VOLTAGE 95009 OTH 01/23/95 i
~
28293 06/05/95 CRYSTAL RIVER 3 BIRMINGHAM J. CRYSTAL RIVER DETERMINED THAT CONSTANT WOLTAGE TRANSFORMERS 95034 02/02/95 FOR VITAL BUS INVERTERS HAD NOT BEEN TESTED BY THE SUPPLIER, ,
GE NUCLEAR, TO THE APPROPRIATE ACCEPTANCE CRITERIA. GE PART NDJ265A1824P001. NO SAFETY CONSEQUENCES OF THE DISCREPANCY WERE DESCRIBED. LICENSEE WILL SUBMIT A REPORT WITHIN 30 DAYS. ,
I 03/22/95 H-95-0057 03/27/95 CRYSTAL RIVER 3 KOSHY T. VSL furnished supplied post-tentioned anchorage Nuts, Botts, 95047 Washers prior to dedication as safety grade.
H 95-0082 03/24/95 CRYSTAL RIVER 3 DENNIG R. FLORIDA POWER CORP / CRYSTAL RIVER 3 PROVIDES SUPPLEMENTAL 95064 03/26/95 INFO REGARDING FAILURE OF CONTSTANT VOLT TRANS FOR VITAL BUS INVERTERS TO MEET ACCEPTANCE CRITERIA. DUTPUT VOLT l REQUIREMENTS NOT MCT. MODIFICATIONS PERFORMED TO CORRECT.
SEE PART 21 LOG #95034.
5 9408100171 04/24/95 CYBEREX KOSHY T. Inverters installed in 1993 outage had inappropriate high 95072 OTH 04/21/95 tenperature shut of f.
27464 04/27/95 DIABLO CANYON 1,2 KOSHY T. POTENTIAL LOW TEMP OVER PRESSURE CONCERNS DURING RHR LOW 95070 E0I 07/01/94 FLOW CONDITIONS.
9503010082 05/21/96 DIABLO CANYON 1,2 DENN!G R. PT21 #95-079 95079 05/14/96 INDIVIDUAL REPORTS THAT JET EXPANSION MODEL APPEARING IN A 1974 BECHTEL TOPICAL MAY HAVE BEEN MISAPPLIED AT DIABLO CANYON DUE TO "MISREPRESENTATs0N" IN THE TOPICAL.
0 07/12/95 DOW CORNING KOSHY T. This is a supplement report to 28079 and 28042 stating the 95139 GEN 07/03/95 potential degradation of RTV product line. The current update in June states that the testing did not reveal any performance deviation in spite of the problems noted in cure dates.
Page:20 01/17/97 EVS-23
. . . _ _ . _ . _ - . . _ - . - _ . . . . . ~ - ~ --..-~..- - . ~ . ~ .- - .. ~. - . - .. ., . .~ . - . . . ~ ._
g I 6
PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY > ;
CLOSING PART21 EVENT ASSIGNMENT MT[ ASSIGNED TO SUBJECT (Event Description) gggR g E
D REPORT VENDOR ;
0 12/18/95 DOW CORNING KOSHY T. This is a final report from Dow Corning regarding the 95177 OTN 12/15/95 deficiency addressed in Part 21 Log 95-103 and EN No: 28042 9504240118 04/12/95 DOW CORNING KOSHY T. 95111 04/12/95 ,
H-95-0005 09/10/% DOW CORNING MODGE V. DOW CORNING CORP PROVIDES UPDATE ON IDENTIFICATION OF ROOT 95004 OTH 04/05/96 !
CAUSE OF ELASTOMERS & ADHESIVE / SEALANT NOT MEETING SPECS.
IMPURITITES IN PIGMENT CAUSED PROB. FIRE PERFORMANCE TESTS ,
TO BE CONDUCTED IN CONJ WITH UL. SEE LOG j
28079 09/10/% DOW CORNING HODGE V. DOW CORNING CORP PROVIDES UPDATED INFO RE TESTING OF %-081 95022 OTH 04/05/96 RTV ADHESIVE / SEALANT INCORP HIGHER PUTRITY GRADE PIGMENT.
MEETS ALL SPECS. FOR SYLGARD 170 SILICONE FAST CURE ELASTOMER /96-081, FIRE PRFRM TESTS TO BE DONE WITH UL. SEE LOG #95004/94322 ET AL. ?
28042 12/15/95 DOW CORNING CORP. KOSHY T. DEGRADATION OF *SELF-EXTINGUISHING" TIME OF DOW CORNING RTV 95103 OTH 11/23/94
%-081.
30645 DRESDEN 2,3 GENERAL ELECTRIC MODEL 12HGA17563 RELAY. % 500 12/04/%
0 07/12/95 DRESSER INDUSTRIAL VA KOSHY T. Report on the use of nonconforming parts on main steam 95114 GEN 07/05/95 safety valves at ANO unit 1. This problem also addressed in a vendor FAX in part 21 file 95115. This problem was i previously reviewed and closed under EN 28634.
H-95-0016 02/24/95 DRESSER INDUSTRIES KOSHY T. Accumulation of corrosion products on governor valve stem. 95011 02/24/95 This event was previously addressed under 50.72 #27762. IN f 94-66 was issued to address the generic inplications. I 0 12/12/95 DRESSER RAND CARTER J. PART 21 LOG #95-202: DRESSER-RAND FINAL REPORT ON POTENTIAL 95202 12/06/95 ^
PROBLEM WITH LOCKNUT D-R PART NO. 75233A06 INSTALLED WHERE THINNER LOCKNUT IS REQUIRED TO PREVENT LOOSENING UNDER VIBRATION. ISSUE IS BEING TRACKED UNDER EN#29111, PART 21 e LOG #95-175.
t
{
Page:21 01/17/97 ETS-23 f
m __, . . . . _ _ _ _ _ _ _ . _ . .m_. _ __ _ _ _ _ . . . _
DART 21 FOLLOW-UP ASSIGNMENTS [
SORTS Plant Name QUERT> l i
CLOSING PART21 EVENT ASSIGNMENT DATE REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) g g
[
29111 12/13/95 DRESSER-RAND CARTER J. PART 21 LOG #95175 - DRESSER RAND MAKES A VERSAL 95175 GEN 08/07/95 NOTIFICATION IN EN#29111 0F A POTENTIAL PROBLEM WITH THE GOVERNOR LINKAGE UNDER SEVERE VIBRATION OR A SEISMIC EVENT.
A LOCK NUT WHICH SECURES THE GOVERNOR LINKAGE MAY NOT HAVE SUFFICIENT THREAD ENGAGEMENT TO GUARANTEE ADEQUATE LOCKING.
LIST OF AFFECTED PLANTS / RECOMMENDATIONS IN PREP.
i 0 12/14/95 DRESSER-RAND CARTER J. PART 21 LOG #95176 - FAX REPORT FROM DRESSER-RAND RE: 95176 08/07/95 NOTIFICATION IN EN#29111 0F A POTENTIAL PROBLEM WITH THE GOVERNOR LINKAGE UNDER SEVERE VIBRATION OR A SISMIC EVENT. A LOCK NUT WHICH SECURES THE GOVERNOR LINKAGE MAf NOT HAVE SUFFICIENT THREAD ENGAGEMENT TO GUARANTEE ADEQUATE LOCKING.
LIST OF AFFECTED PLANTS / REC 0pW9ENDATIONS IN PREP.
08/14/95 0 12/13/95 DRESSER-RAND CARTER J. The short name for this issue is cfw valve stem. The 94216 GEN i description of the lead Part 21 report given in the old TQM dBase file is:
94216 T TOLEDO EDISON / DAVIS BESSE 1 PROVIDES UPDATED INFO REGARDING LACK OF FULL ENGAGEMENT OF SETSCREW USED TO ANCHOR VALVE STEM COUPLING TO TRIP THROTTLE VALVE STEM FOR AFW j TURBINE. VENDOR TO PROVIDE PROPER PROCEDURE. SEE LOG
- 94212/94251/94262.
Additional related Part 21 reports are described in the closeout section below. j 0 09/06/95 DRESSER-RAND CARTER J. PART 21 LOG #95178 - FAX REPORT FROM DRESSER-RAND: TERRY 95178 i 08/25/95 TURBINE GOVERNOR LINKAGE LOCK NUT POTENTIAL FAILURE UNDER V!BRATION.
02/14/96 0 02/14/ % DRESSER-RAND CARTER J. Dresser-Rand recognizes that certain operating conditions 96160 may Lead to corrosion and governor valve stem binding with a resultant turbine overspeed trip. They stamitted a letter that reported a new design has been prepared for the governor valve stem and that it uses 718 inconel with a chromita carbide coating along the gland area. New and improved packing and washers were also reconenended.
Page:22 01f17/97 ETS-23
3
- PART 21 FOLLOW-UP CSSIGNMECTS ;
SORT > Plant Name QUERY > ,
i PART21 EVENT I ASSIGNMENT CLOSING E
D REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) Nysgga g i 28841 12/06/95 ELGAR GREENE T. PART 21 LOG #95129, ISSUE NUMBER 95013 - CLINTON REPORTS 95129 OTN 06/09/95 FAILURE OF TWO PWM DRIVE LOGIC CARDS FOR ELGAR INVERTERS, PART NUMBER 642-108-40 REV F. ONE CARD NEVER MADE IT INTO SERVICE AS THE PORTION THAT CONTROLS THE SCRs DIDN'T WORK, 2 AND THE OTHER FAILED AFTER FOUR TO SIX HOURS OF OPERATION ,
WHEN IT WAS PLACED IN A SAFETY RELATED INVERTER AS PART OF A l SCHEDULED MAINTENANCE. BOTH BOARDS WERE RETURNED TO ELGAR FOR ANALYSIS. CAUSE CF FAILURE UNKNOWN. ,
06/09/95 0 12/06/95 ELGAR GREENE T. PART 21 95-130 95130 OTH THIS PIECE OF CORRESPONDENCE IS THE FAX FROM CLINTON THAT <
COVERS THE SAME MATERIAL AS PART 21 LOG #95129 (EN#28841).
CLINTON REPORTS FAILURE OF TWO PWM DRIVE LOGIC CARDS FOR i ELGAR INVERTERS, PART NUMBER 642-108-40 REV F. ONE CARD !
I NEVER MADE IT INTO SERVICE AS THE PORTION THAT CONTROLS THE SCRs DIDN'T WORK, AND THE OTHER FAILED AFTER FOUR TO SIX l HOURS OF OPERATION WHEN IT WAS PLACED IN A SAFETY RELATED INVERTER AS PART OF A SCHEDULED MAINTENANCE. BOTH BOARDS WERE RETURNED TO ELGAR FOR ANALYSIS.
l l
08/07/95 0 12/06/95 ELGAR GREENE T. PART 21 LOG #95170 - INTERIM REPORT FROM ILLINOIS POWER 95170 (CLINTON) RE: FAILURE OF ELGAR INVERTER PWM DRIVE LOGIC -
CARD. TESTING BY ELGAR NOT COMPLETE YET. l I
12/04/95 0 12/06/95 ELGAR GREENE T. PART 21 LOG #95-208: FINAL REPORT FROM ILLINOIS POWER ON 95208 PROBLEM WITH LOGIC CARDS FOR ELGAR INVERTER. TESTING INCONCLUSIVE. I i
?
Page:23 I ETS-23 01/17/97 i
PART 21 FOLLOW-UP ASSIGNMEOTS SORT > Plant Name QUERT>
CLOSING PART21 EVENT ASSIGNMEOT DATE PjPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) an.BGER M 0 05/23/% ELLIS & WATTS DENNtG R. PART 21 LOG #95225: The deficiercy identified a f an shaf t 95225 05/20/ %
failure initiation echanism on Ellis and Watts safety-related coolers and a condenser. Specifically, the components identified as having damage are 1-PMcL-30-175-A(1A-A RHR ptsup room cooler), -COND-31-289 (480 V board room condenser 28-B), 1-PMCL-30-183-A (1A-A CCP room cooler A-A),
2-PMCL-30-190- A (CCS pump and Unit 1 AFW ptmp cooler A-A),
and 1-PMCL-30-191-B (CCS ptmp and Unit 1 AFW ptsup cooler B-8). Unit 1 was in cold shutdown, prior to Mode 6 (initial fuel loading).
The mechanism of failure was the bearing moving relative to the fan shaft. Overtensioning of belts was identified as the cause. Maintenance Instruction (MI)-0.16, " Maintenance Guidelines For Belt Driven Equipment," had been initiated in 1988 as a result of deficiencies written on air handling equipment. The instruction provided a belt tensioning method base on belt deflection (Browning Belt Manufacture guidance). This resulted in high forces / loads on the shaft and bearings.
Because of the identified condition, the required 100 days of continuous operation to support safe shutdown following a design basis accident may not be assured, since potential fan running time before failure could not be determined.
However, the fans had not failed prior to removal from service for repairs.
Forty one safety-related/ quality-related Ellis and Watts belt driven fans required for Unit 1 operation have been identified. As part of this review, eighteen were determined to be required to be inspected prior to mode 6.
Inspection has been performed on the eighteen units plus 2-Core-31-289. Five of the nineteen were identified to have damaged shafts and have been repaired. The corrective actions include a change to the method of tightening the belts for avoiding shaft damage.
Page:24 01/17/97 ETS-23
I
- PART 21 FOLLOW-UP AS$1GNMEOTS SORT > Plant Name QUERY >
t CLOSING PART21 EVENT ASSIGNMEDT DATE REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) g g 0 ENGINE SYSTEMS INC./G TAPPERT J. PART 21 #96760 - ENGINE SYSTEMS INC. REPROTS THAT FOUR 96760 11/12/ %
EXCITATION CONTACTORS (De #9562575) SOLD TO GPU/0YSTER CREEK MAD A JUMPER WIRE LEFT IN PLACE THAT SHOULD HAVE BEEN ;
REMOVED FOR THE GPU APPLICATION. THE WIRE WOULD CAUSE A SHORT CIRCUIT IF WOT REMOVED. OYSTER CREEK WAS THE ONLY CUSTOMER.
0 08/16/% FARWELL & HENDRICKS HUNEMULLER N. The short name for this issue is relay th oload. 94199 GEN 08/15/95 The description of the lead Part 21 report given in the old TQM cNiase file is:
94199 F - TENNESSEE VALLEY AUTHOR /BELLEFONTEREPORTS MALFUNCTION OF .
TEMPORARILY OPEN & RECLOSE W/0 FULLY TRIPPING. COULD RESULT IN UNACCEPTABLE CONSEQ TO SYSTEM PROCESSES.
Additional related Part 21 reports are described in the closecut section below.
9611060249 FARWELL & HENDRICKS SKEEN D. NEW ISSUE. MSD B255 tatching relay with DC untatching coit % 780 11/20/ % becomes untatched without the reset colt being energized.
PSE&G has identified 8 instattations.
HUNEMULLER N. A SPARE GENERAL ELECTRIC MOLDED CASE CIRCutT BREAKER, TYPE 94295 OTH 12/16/94 9412010280 10/16/95 FITZPATRICK 1 THJK, WAS BEING BENCH TESTED IN PREPARATION FOR INSTALLATION IN A SAFETY RELATED APPLICATION. THE BREAKER OVERCURRENT [
TRIP FAILED TO PERFORM WITHIN THE SPECIFIED TIME- CURRENT I CURVE. THE BREAKER WAS NOT INSTALLED. A SECOND BREAKER FROM SPARE PARTS INVENTORY WAS BENCH TESTED WITH SATISFACTORY RESULTS. ,
t 02/01/96 FITZPATRICK 1 HUNEMULLER N. LICENSEE WAS NOTIFIED BY ITT BARTON THAT MODELS 200, 227A, 95096 OTH 04/11/95 1-95-0053 ,
228A, AND 2894 DIFFERENTIAL PRESSURE INSTRUMENTS MANUFACTURED WITH "B-FILL" FLUID MAY NOT FUNCTION IN RADIATION FIELDS GREATER THAN 1 MEGARAD. THE ETHYLENE GLYCOL ,
USED IN THE "B-FILL" TENDS TO BREAK DOWN UNDER HIGH RADIATION, AND THIS FACT MAY NOT HAVE BEEN COMMUNICATED TO PURCHASERS. i L
Page:25 01/17/97 ETS-23
. x.- .- - - - - ._..-.. - - - -, . . - - . - . ~ .-. . . ~ . - . . ~ . . .
e PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name ;
QUERY >
CLOSING PART21 EVENT ASSIGNME::T E
D REPORT T GAT 1 VENDOR ASSIGNED TO SUBJECT (Event Description) Nypggit g SEVERAL SAFETY RELIEF VALVE PILOTS WERE NOT FUNCTIONING WHEN 96680 EDI t 03/04/% 30039 04/18/ % FITZPATRICK 1 BIRMINGHAM J.
TESTED DURING REFUELING.
03/22/ % 30149 FITZPATRICK 1 SKEEN D. POTENTIAL FOR CIRCUIT BREAKER SPRING CHARGING MOTOR LIMIT 96310 Teo SWITCH FAILURES TO AFFECT 4KV CIRCUlf BREAKERS IN BOTH SAFETY DIVISIONS. PART 21 REPORT (VIA LER) EXPECTED.
01/12/95 H-95-0002 03/30/95 FLORIDA POWER CORP. GREENE T. VSL CORP / FLORIDA POWER CORP REPORTS DELIVERY OF CGMERCI AL 95002 GRADE STUDS, NUTS, WASHERS WHEN SAFETY-RELATED QUALITY WAS ORDERED. CAUSE OF NONCONFORMANCE IS UNDER REVIEW.
08/16/95 29033 09/13/95 FOXBORO TAPPERT J. The problem addresses an abnormal power draw by DC/DC 95159 OTH converter added to 1E non 1E isolation module. This problem "
is also reported under vendor record 95160. It applied to Haddam Neck plant.
08/16/95 9507280064 08/16/95 FOXBORO TAPPERT J. 95160 0 04/19/96 FOXBORO SKEEN D. PART 21 LOG #96300 - FOXBORO REPORTS POTENTIAL DEFECT FOR N- 96300 OTH 04/16/ % '
820 SERIES TRANSMITTERS WITH ANALOG OUTPUT. PINS MAY DELAMINATE UNDER HIGH AMBIENT THERMAL CYCLES. NO FAILURES IN NUCLEAR APPLICATION. F AILURES MAVE OCCURRED IN COpMERCI AL APPLICATIONS IN OUTDOOR USE. LETTERS TO BE SENT TO NOTIFY ,
NUCLEAR CUSTOMERS. SPECIAL INSPECTION BRANCH IS AWARE OF !
PROBLEM.
05/31/96 9605240007 09/11/ % FOXBORO SKEEN D. PART 21 LOG #96380 - L1R FROM FOXBORO DATED 5/1/96 RE: 96380 AUT0/ MANUAL MODE SWITCH PUSH 9UTTON ON FOX 8ORO N-2AX+M_N OUTPUT STATION DOESN'T WORK 100% SOMETIMES THE BUTTON MUST BE PUSHED AGAIN TO GET THE SWITCH CONTACTS TO MAKE UP PROPERLY. CUSTOMERS BEING NOTIFIED. ADVICE IS TO FIX WHEN MALFUNCTION OCCURS, OTHERWISE DO NOTHING.
0 FRAMATONE/ANO, CR3 HCOGE V. PART 21 LOG #96390 - FRAMATOME AS SUCCESSOR TO B&W 96390 05/31/ %
TECHNOLOGIES REPORTS THAT MATERIAL USED FOR PERMANENT CANAL ,
SEAL PLATES CONTAINS WELDS CONTRARY TO ASME A479. NO PROBLEMS HAVE BEEN OBSERVED IN SERVICE AT CRYSTAL RIVER OR ARKANSAS NUCLEAR ONE.
r t
Page:26 01f17f97 iTS-23 ,
i r
. - . . . - ___ -..- .. . -- . . . . - ~ - .. .- _
\
PART 21 FOLLOW-UP CSSIGNMEDYS SORT > Plant Nant QUERY > ,
i ASSIGNMENT CLOSING PART21 EVENT DATE REPORT DAlg VENDOR ASSIGNED TO SUBJECT (Event Description) NWWER E 12/04/95 29535 12/05/95 GE-NE DENNIG R. PART 21 LOG #95-219: GE REPORTS THAT VALVES SUPPLIED ONLY TO 95219 PILGRIM AND NOT YET INSTALLED HAD VALVE PACKING MATERIAL THAT DID NOT CONFORM TO GE SPECIFICATIONS. THE VALVES WERE .
PROCURED FROM RING-0 VALVE spa 0F ITALY. CORRECTIVE ACTIONS HAVE BEEN TAKEN. NEW MATERIAL WAS INSTALLED BEFOR THE VALVES WERE PLACED IN SERVICE. SINCE THE ONLY VALVES INVOLVED HAVE BEEN FIRED, AND WERE NEVER IN SERVICE IN THE DISCREPANT CONDITION, NO FURTHER ACTION IS REQUIRED.
I 12/04/95 0 12/05/95 GE-NE DENNIG R. PART 21 LOG #95-220: FAX - GE REPORTS THAT VALVES SUPPLIED 95220 ONLY TO PILGRIM AND NOT YET INSTALLED HAD VALVE PACKING MATERIAL THAT DID NOT CONFORM TO GE SPECIFICATIONS. THE .
VALVES WERE PROCURED FROM RING-0 VALVE spa 0F ITALY.
CORRECTIVE ACTIONS HAVE BEEN TAKEN. NEW MATERIAL WAS INSTALLED BEFOR THE VALVES WERE PLACED IN SERVICE. SINCE THE ONLY VALVES INVOLVED HAVE BEEN FIXED, AND WERE NEVER IN SERVICE IN THE DISCREPANT CONDITION, NO FURTHER ACTION IS REQUIRED.
08/09/95 0 08/28/95 GENERAL ELECTRIC HUNEMULLER 4. The description of this Part 21 report given in the old TQM 93440 GEN dBase file is:
93440 F GENERAL ELECTRIC REPORTS EXPRNCNG PROB WITH GE CR2940 SWITCH ASSBLES DURING FACTRY TESTNG AS EVIDENCED BY FAILURE OF CYLINDER LOCK SELECTOR SPRING TO RETURN SWTCH TO ORIG POSITION BY SPRING FORCE. TESTG UNDERWAY. NO FIELD .
FAILURES RPTD. SEE LOG #94046. ,
i 05/GB/96 9411070265 05/21/ % GENERAL ELECTRIC HODGE V. PT21 #95-019 95019 OTH Temessee Valley Authority / Watts Bar 1/2 Reports separation of pin connecting trip coil link to crank & falling out of GE magneblast C/B due to failure of pin weld. 206 C/Bs inspected and 50 percent showed defects. See Log 94182.
30539 09/23/ % GENERAL ELECTRIC CARTER J. PART 21 LOG #96470 - GESTAR 11 GENERIC SAFETY LIMIT MINIMUM 96470 GEN 05/29/ %
CRITICAL POWER RATIO (MCPR) MAY BE NONCONSERVATIVE WHEN APPLIED TO SOME CORE AND FUEL DESIGNS.
0 CENERAL ELECTRIC SKEEN D. GE EVALUATION OF FAILURES OF RMS-9 OVERCURRENT TRIP DEVICE % 540 10/01/ %
PROGRAMMERS WITH INSTANTANEOUS TRIP FUNCTIONS. RELATED TO PT21 95133.
Page:27 01/17f97 EVS-23
\
PART 21 FOLLOW-UP ASSIGNMECTS i
SORT > Plant Name QUERT>
ASSIGNMEDT CLOSING PART21 EVENT DATE REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) gggg g 0F/17/95 25955 07/19/95 GINNA 1 KOSHY T. Fisher Controls valve supplied a butterfly valve with air- 95148 OTN to-open instead of air-to-close. The valve was stoptied conenercial grade and was dedicated by the licensee. The dedication process did not identify the problem.
This problem was also reported under Vender File 95149. ,
This was a faxed report of the same.
92/04/95 29247 12/05/95 GINNA 1 BIRMINGHAM J. PART 21 LOG #95-193: ROCHESTER GAS AND ELECTRIC REPORTS THAT 95193 TUTHILL INTERNAL GEAR POSITIVE DISPLACEMENT PUMP MODEL 2CF-CC WAS PROCURED AS " EXACT REPLACEMENT" FOR OEM EQUIPMENT.
PUMP MET ALL PROCUREMENT SPECS, WAS PROCURED AS C0petERCIAL GRADE AND DEDICATED BY ROCHESTER CAS AND ELECTRIC. POST INSTALL ATION TESTING INDICATED ADJUSTMENTS NEEDED TO ATTAIN PROPER OPERATING FUEL OIL PRESSURE. LACK OF ADJUSTMENT WOULD HAVE RESULTED IN LOWERED DIESEL OUTPUT.
12/04/95 0 12/06/95 GINNA 1 BIRMINGHAM J. PART 21 LOG 95-194: FAX FROM ROCHESTER GAS AND ELECTRIC. 95194 ROCHESTER GAS AND ELECTRIC REPORTS THAT TUTHILL INTERNAL GEAR POSITIVE DISPLACEMENT PUMP MODEL 2CF-CC WAS PROCURED AS
" EXACT REPLACEMENT" FOR DEM EQUIPMENT. PUMP MET ALL PROCUREMENT SPECS, WAS PROCURED AS COMMERCIAL GRADE AND DEDICATED BY ROCHESTER GAS AND ELECTRIC. POST INSTALL ATION TESTING INDICATED ADJUSTMENTS NEEDED TO ATTAIN PROPER OPERATING FUEL OIL PRESSURE. LACK OF ADJUSTMENT WOULD HAVE ,
RESULTED IN LOWERED DIESEL OUTPUT.
OF/1F/95 0 07/17/95 GINNA 1 KOSHY T. 95149 02/15/96 29247 03/27/96 GINNA 1 BIRMINGHAM J. PT21 % -120 96120 i
REPORT THAT TUTHILL PUMP MODEL 2CF-CC REQUIRED ADJUSTMENT TO ENSURE THAT PROPER FUEL OIL PRESSURE WAS ATTAINED FOR EMERGENCY DIESEL GENERATOR.
10/21/96 31128 GINNA 1 KOT2 ALAS M. U.S. ELECTRIC MOTORS SERVICE WATER PUMP MOTOR FAILED ITS % 550 POST-MODIFICATION FUNCTIONAL TEST. LICENSEE DISCOVERED DAMAGED LEADS. LICENSEE PURCHASED MOTOR CafetERICAL-GRADE +
AND C0fetERCIALLY DEDICATED IT. ,
Page:28 01/17/97 ETS-23
- - _ - _ . . . _ . . . . ___._...__u_.--_.____._-_____-_ __._ _ _ _ _ _ _ - _ _ _ _ _ _ - -- v- -.
. m _ _ . _ . _ _ _ _ _ . _ _ _ . . . _ _ ._ __ _ _ _ _ _ _
5 PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT ASSIGNME:T DATE REPORT E D VENDOR ASSIGNED TO SUBJECT (Event Description) IllMER JJP1 i 12/04/95 29426 03/27/ % GOULD/ITE SKEEN D. ILLINOIS POWER (CLINTON) REPORTS SPURIOUS ACTION OF 95213 OTH l GOULD/ITE (NOW A88) SOLID STATE TRIP DEVICE MODEL TYPE SS-13, PART NUMBER 609901-T012. TESTING INCONCLUSIVE.
12/04/95 0 12/05/95 GOULD/ITE SKEEN D. PART 21 LOG #95-214: FAX FROM ILLINOIS POWER (CLINTON) 95214 OTH PROVIDING DETAILS OF SPURIOUS ACTUATION OF SOLID STATE TRIP DEVICE TYPE SS-13, PART NUMBER 609901- T012. i 28328 10/16/96 HADDAM NECK 1 BENNER E. DURING MOV TESTING, TWO SERVICE WATER BYPASS VALVES FAILED 95041 E01 ,
02/03/95 TO OPEN FULLY WHEN TESTED AGAINST FULL PRESSURE DIFFERENTIAL. VALVES TRAVELLED FOR 1.5 SECONDS OUT OF THE 9 SECONDS TO OPEN FULLY, THEN TORQUE SWITCH TRIPPED. LICENSEE ,
SET TORQUE LIMIT HIGHER IN ORDER TO GET VALVES TO OPEN.
0 04/05/ % HOLTEC WANG E. PART 21 #96040 - HOLTEC REPORTS PROBLEM WITH RESULTS FROM 96040 GEN 02/05/ %
VARIOUS VERSIONS OF ANSYS. LETTER STATES THAT PROBLEM MAS NO AFFECT ON HOLTEC SAFETY RELATED CALCS FOR LICENSEES. ,
i 9607170075 09/10/96 HOLTEC/ANSYS GREENE T. PART 21 LOG #96044 - ADDITIONAL INFORMATION FROM ANSYS ON 96044 OTH 08/08/96 '
THE RESOLUTION OF PROBLEMS EXPERIENCED BY HOLTEC. LETTER DATED 7/11/%. l I
01/27/95 1-95-0009 05/30/95 HOPE CREEK 1 HODGE V. DURING A CORE SPRAY SYSTEM IST A PUMP DISCHARGE CHECK VALVE 95027 E01 [
HUNG OPEN. FOLLOWUP INSPECTION NOTED BODY DEFORMATION THAT i MAY HAVE RESULTED FROM EXCESSIVE DISK TRAVEL. A SIMILAR l CONDITION WAS NOTED ON ANOTHER VALVE I A SYSTEM THAT HAD >
EXPERIENCED FLOW AND PRESSURE OSCILLATIONS OF THE TYPE l ASSOCIATED WITH CHECK VALVE ANOMALIES. THE VALVES ARE [
ANCHOR DARLING SWING CHECK VALVES OF VARIOUS DIMENTIONS 12",
16", 20".
11/11/94 28014 Of,/16/95 HOPE CREEK 1 HODGE V. Air operated gate valves, utilizing Hitler actuators, in the 95074 E01 room cooler water supply lines failed to open (safety ,
function) in two of the EDG rooms during surveillance.
Problem seems to be related to frequency of operation. Hope Creek has 32 valves of this type. Licensee mechanically agitated the valves to open them ard began short term compensatory action of weekly testing for the other valves.
Minimal safety significance at Hope Creek.
Ref: BGCTS95-093 (Hodge), TAC M91746 ETS-23 Page:29 otftyf97 L
_ _ _ _ _ _ . _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ . _ . _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ . - - _ ._- _ - _ _ _ . . _ _ _ _ _ _ _ _ _ _z
. - - . - . =- - - _ . - ... _- . - - -.. . _ . - .
\
PCRT 21 FOLLOW-UP ASSIGNMECTS i
SORT > Plant Name QUERY >
ASSIGNMEDT CLOSING PART21 EVENT DATE REPORT DATE VENDOR ASSIGNED TO SUOJECT (Event Description) g g 06/30/95 9505030198 07/06/95 HOPE CREEK 1 DENNIG R. REPORT FROM NOPE CREEK ON INCORRECT DIMENSIONAL TOLERANCES 95131 [
OF ANCHOR-DARLING SWING CHECK VALVE CCpW'ONENTS. l 07/31/95 0 04/03/ % HOPE CREEK 1 HODGE V. Pt 21 95-082 - FAX report from Hope Creek on incorrect 95082 dimensional tolerances of Anchor- Darling valve components.
Related to BGCTS95-091, TAC M91646 (Hodge), Pt21 95027, and ,
Pt21 95131. ,
i
?
02/15/96 0 HOPE CREEK 1 GREENE T. PART 21 LOG #96150 - HOPE CREEK LICENSEE PROVIDES AN INTERIM 96150 REPORT (PART 21 REPORTABILITY NOT YET DETERMINED DUE TO LACK OF ROOT CAUSE) CONCERNING VALVES USED IN THE SCRAM DISCHARGE VOLUME APPLICATION. THE VALVES ARE 2500 LB GLOBE VALVES MANUFACTURED BY HAMMEL DAHL. VALVE DID NOT GO TO THE FULLY CLOSED POSITION DbRING TESTING.
05/06/ % 0 IDEAL ELECTRIC GREENE T. PART 21 LOG #96340 - ILLINOIS POWER (CLINTON) REPORTS THAT 96340 IDEAL ELECTRIC THE MANUFACTURER OF THE GENERATOR PORTION OF THEIR DIVISIONS 1 AND 2 EDGS, HAD DISCOVERED AN ERROR IN THE :
CALCULATION OF THE GENERATOR ROTOR MASS. NO SEISMIC IMPLICATIONS, BUT FREQUENCY AND TORSIONAL ANALYSIS UNDERWAY.
05/30/ % 9605070306 06/12/96 IDEAL ELECTRIC /CLINTO GREENE T. PART 21 LOG #96341 - ILLINOIS POWER REPORTS IN FINAL REPORT 96341 THAT INCORRECT MASS CALCULATION FOR GENERATOR ROTOR SUPPLIED !
BY IDEAL HAS NO AFFECT ON PERFORMANCE AND CONDITION IS ACCEPTABLE AS IS. t 03/16/95 28502 04/25/95 INDIAN POINT 2 GREENE T. LICENSEE REPORTS THAT 1/4 INCH LIFT CHECK VALVES 95062 OTH MANUFACTURED BY NUPRO (MODEL SS-53S4) HAD FLOW ARROW POINTING IN THE WRONG DIRECTION. 10 VALVES IN THE SAME LOT WERE AFFECTED, ALL PROCURED AS C0f00ERCIAL GRADE AND DEDICATED BY THE LICENSEE. NO FUNCTIONAL CHECK WAS PERFORMED AS PART OF DEDICATION AND PROCEDURES HAVE BEEN REVISED. NO VALVES WERE ACTUALLY PLACED IN SERVICE. NUPRO INDICATED THAT
- PROBLEM WAS DUE TO ISOLATED HUMAN ERROR.
04/13/95 1-95-0038 04/17/95 INDIAN POINT 2,3 KOSHY T. Pacific pu m used in SI systems could be disabled from exial 95068 movement of i gletters. This problem results from inadequaltety torqued iocknut.
29248 INDUSTRIAL NUCLEAR NMSS Ind nuct radiography source connector 95195 NMS 02/2F/96 Page:30 01/17/97 ETS-23
P!AT 21 FOLLOW-UP ASSIGNME::TS SORT > Plant Name QUERY >
ASSIGNMENT CLOSING PART21 EVENT g REPORT p.ATg T YENDOR ASSIGNED TO SUBJECT (Event Description) g g 12/04/95 0 12/05/95 INEL DENNIG R. PART 21 LOG #95-217: INEL REPORTS THAT ISOLAtl0N VALVE 95217 ASSESSMENT SOFTWARE (IVA) VERSION 4.10 CONTAINS AN ERROR THAT AFFECTS CALCULATIONS FOR GATE VALVES IN THE OPENING =
DIRECTION. ALL REGISTERED USERS NOTIFIED, INEL IS UNABLE TO ASSESS SIGNIFICANCE DUE TO LACK OF KNOWLEDGE OF SPECIFIC '
APPLICATIONS.
28593 12/06/95 INFO NOTICE AUTH0 SKEEN D. ON 2/18/95, MSIVs AT LASALLE UNIT 2 FAILED TO CLOSE BECAUSE 95143 GEN 04/03/95 ASCO NP 8323 PIL;OT VALVES STUCK. IN 1989, ASCO RECOMMENDED THAT THE LICENSEE DISCONTINUE USE OF THIS MODEL.
05/15/95 9503020053 05/17/95 INGERSOLL DRESSER PUM KOSHY T. Pressure reducing sleeve and its locknut problems in safety 95085 OTH injection ptmps. This information was first received under EN 27924.
9606050217 08/05/96 INGERSOLL-DRESSER CARTER J. PART 21 #96-067 96067 08/05/ %
9505240268 07/12/95 ITE KOSHY T. This event is addressed in Part 21 files 95134, 95126 and in 95125 GEN 07/05/95 morning report 4-95-35. This problem addresses the use of and over-sized cable lug used in ITE switchgear.
4-95-0035 04/24/95 ITE IMPERIAL KOSHY T. Oversized cable Anp cable lugs installed in ITE 480 Volt 95069 OTH 04/19/95 switchgear.
i 0 07/12/95 ITE/ABB KOSHY T. Use of oversized AMP cable lugs used in ITE switchgear. 95134 GEN 07/03/95 ,
28267 03/03/95 ITT BARTON HODGE V. ITT BARTON REPORTS THAT 288A AND 289A DIFFERENTIAL PRESSURE 95018 E01 01/24/95 SWITCHES SHOWED CONTACT CHATTER DURING SEISMIC TESTING AT HIGH ACCELERATIONS (UP TO 12G).
28392 03/13/95 ITT BARTON HODGE V. ITT BARTON PROVIDES UPDATE ON TESTING FOR 288A/289A CHATTER 95052 02/22/95 DURING SEISMIC EVENTS.
0 04/04/ % ITT BARTON HODGE V. Pt21 95-094 - Letter report from ITT Barton on dp indicating 95094 07/31/95 '
switch, Models 288A, 2894, chattering at 129 but with no functional degradation. Related to BGCTS95-090 (Hodge), TAC M91645, and Pt21 95018.
Page:31 01f17f97 ETS-23
- - . , _ - ---.-~.- ~ . - . - - .- - ._ - . . . ~ . . - . .-- . - - - a ..
I i
PART 21 FOLLOW-UP ASSIGNME%TS SORT > Plant Name
+
QUERY >
ASSIGNMENT CLOSING PART21 EVENT E
D REPORT E D VENDOR ASSIGNED TO SUBJECT (Event Description) NUMBER E 06/10/% 9607030156 ITT BARTON SKEEN D. PART 21 LOG #96460 - ITT BARTON REPORTS THAT CERTAIN LOTS OF 96460 ComIERCIAL GRADE POTENT 10 METERS USED IN MODEL 765/765A DIFFERENTIAL PRESSURE ELECTRONIC TRANSMITTERS HAVE BEEN SUPPLIED WITH LUBRICATION NOT IN COMPLIANCE WITH PURCHASE SPECS.
06/03/ % 0 ITT BARTON/CLINTON HODGE V. PART 21 LOG #96420 - CLINTON LICENSEE REPORTS THAT AN ITT 96420 !
BARTON PUPP ASSEMBLY FOR A SERIES NH95 NYDRAMOTOR ACTUATOR DID NOT DEVELOP SUFFICIENT PRESSURE. RETURNED TO ITT BARTON i FOR EXAMINATION, SCHEDULED TO BE CMPLETED 12/31/M.
28585 05/03/95 KEPCO DENNIG R. INTEGRATED RESOURCES, INC. IDENTIFIED HIGH FAILURE RATE OF 95075 GEN 04/13/95 TWO TRANSISTORS USED IN A KEPCO POWER SUPPLY sRMx24-D-20804 ,
WHEN REFURBISHING POWER SUPPLIES FROM NihE MILE PolNT 2.
THE POWER SUPPLIES WERE BUILT BY TDK IN JAPAN FOR KEPCO WHO SOLD THEM TO GE WHO SUPPLIED THEM TO NUCLEAR CUSTOMERS.
THESE POWER SUPPLIES ARE KNOWN TO BE USED IN APRM CIRCUITS FOR NINE MILE POINT 2 AND PERRY. THE TRANSISTORS ARE UNDERRRATED FOR THE APPLICATION AND AS A RESULT FAIL PREMATURELY IN SERVICE. THE RESULT IS TO FAIL THE OUTPUT OF THE POWER SUPPLY AND THUS FAIL THE POWERED EQUIPMENT. THUS i THIS FAILURE MECHANISet IS SELF-ANNOUNCING AND CORRECTABLE UPON FAILURE. THE FAILURE OF MULTIPLE POWER SUPPLIES IS NOT SYNCHRONIZED, THUS MULTIPLE CHANNELS ARE UNLIKELY TO BE IMPACTED AT THE SAME TIME. SAFETY SIGNIFICANCE IS MINIMAL.
0 06/02/95 KEPCO DENNIG R. PART 21 #95112. CORRESPONDENCE CONSISTS OF EN 28585 UPDATE 95112 05/26/95 REFLECTING AVAILABILITY OF REPORT FROM INTEGRATED RESOURCES INC. RE KEPCO POWER SUPPLIES. PREVIOUS ASSIGNMENT DATED 041395 TO DENNIG WILL DOCUMENT DISPOSITION.
0 06/08/95 KEPCO DENNIG R. PART 21 LOG #95113 - THIS CORRESPONDENCE IS THE FINAL REPORT 95113 06/06/95 FROM INTEGRATED RESOURCES CORPORATION ON DEFICIENCIES CAUSE BY MARGINALLY SPECIFIED TRANSISTORS IN KEPCO MODEL #RMX 24-D-20804 POWER SUPPLIES. THIS ITEM RELATES TO A PREVIOUS ASSIGNMENT TO DENNIG DATED 041395 AND RELATED TO EN 28585.
CLOSEOUT IS DOCUMENTED AGAINST THAT ASSIGNMENT.
9507170404 08/18/95 KEYSTONE CARTER J. PART 21 LOG #95172 - LETTER REPORT FROM KEYSTONE RE: AGCO 95172 08/07/95 MODEL 81P RELIEF VALVES. PRESSURE ADJUSTMENT SHOULD BE WITH FLUID, NOT AIR WHICH COULD GIVE NON-CONSERVATIVE RESULTS.
Page:32 01/17/97 73 23
I '.
PART 21 FOLLOW-UP CSSIGNMECTS SORT > Plant Name QUERY >
CLCSING PART21 EVENT A$$IGNMECT DATE REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) NpaggR g 0 09/06/95 KEYSTONE CARTER J. PART 21 LOG #95180 - UPDATE OF EN#29066 AND FAX OF RESULTS 95180 08/25/95 OF TESTING RE: AGC0 MODEL 81p RELIEF VALVE SET POINT PROBLEM IF FIELD SET WITH AIR RATHER THAN WATER. CLOSED OUT UNDER PREVIOUS ASSIGNMENT EN#29066.
30999 LASALLE 1,2 SKEEN D. LASALLE REPORTS RESPONSE TO GE-NE PART 21 NOTIFICATION %540 GEN 09/16/96 CONCERNING RMS-9 OVERCURRENT TRIP DEVICE PROGRA MERS. REPORT INDICATES GE HAS IDENTIFIED 27 AFFECTED PLANTS AND CONCLUSION THAT ISSUE IS VALID PART 21 CONCERN.
31073 LASALLE 1,2 SKEEN D. EFFECTIVE DIAPHRAGM AREA IN A0Vs MAY BE SIGNIFICANTLY 96250 EDI 10/08/96 SMALLER THAN ASSUMED. VALVES MAY NOT FUNCTION IN ISOLATION APPLICATION. ANCHOR DARLING IS RESPONSIBLE VENDOR, ALTHOUGH VALVES WERE ORIGINALLY MANUFACTURED BY ANOTHER COMPANY.
9503170049 04/24/95 LIMITOROUE KOSHY T. Worm shaf t clutch gear assenbly on two MOVs experiences 95071 OTH 04/21/95 premature failure.
0 LIMITORQUE GREENE T. RECEIVED INTERIM REPORT FROM COMED DETAILING CONCERNS ABOUT 95104 05/1G/95 TYPE 1018 MOTOR PINION KEYS.
29060 09/11/95 LIMITORQUE WEN P. PART 21 LOG #95-161 - LIMITORQUE REPORTS THAT BASE ON 95161 GEN 07/19/05 NOTIFICATION FROM TVA THEY ARE REPORTING A POTENTIAL PROBLEM WITH MANUAL-TO-AUTOMATIC (ELECTICAL) OPERATION FOR SMB/SB/SBD-00 MOV ACTUATORS WITH CAST DATES OF 1979 OR EARLIER. THE "OUTSIDE CLUTCH TRIPPER" CAN BECOME WEDGED AGAINST THE OPERATOR HOUSING AND PREVENT THE TRANSITION FROM MANUAL TO AUTOMATIC OPERATION. PROBLEM IS IMMEDIATELY DETECTABLE IF ELECTRICAL OPERATION IS STANDARD PROCEDURE FOLLOWING ANY MANUAL OPERATION.
0 08/09/95 LIMITORQUE WEN P. PART 21 LOG #95-162 - LIMITORQUE REPORTS THAT BASE ON 95162 OTH 07/19/95 NOTIFICATION FROM TVA THEY ARE REPORTING A POTENTIAL PROBLEM WITH MANUAL-TO-AUTOMATIC (ELECTICAL) OPERATION FOR SM8/SB/SBD-00 MOV ACTUATORS WITH CAST DATES OF 1979 OR EARLIER. THE "OUTSIDE CLUTCH TRIPPER" CAN BECOME WEDGED AGAINST THE OPERATOR HOUS NG AND PREVENT THE TRANSITION FROM MANUAL TO AUTOMATIC OPERATION. PROBLEM IS IMMEDIATELY DETECTABLE IF ELECTRICAL OPERATION IS STANDARD PROCEDURE FOLLOWING ANY MANUAL OPERATION.
Page:33 01/17f97 ETS-23
~
I i PART 21 FOLLOW-UP ASSIGNMECTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT ASSIGNMEDT E
D REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) g g 08/16/95 0 08/22/95 LIMITORQUE KOSHY T. This Limitorque letter informs all licensees about the 95169 possibility of certain Limitorque operators being prevented from shitO ng to automatic from manual on motor start. This was first reported in EN 29060.
0 11/0/95 LIMITORQUE DENNIG R. PART 21 LOG 895185 - COMMONWEALTH EDISON PROVIDES A FINAL 95185 91/03/95 REPORT ON INVESTIGATION OF POSSIBLE DEFECT RELATED TO HARDNESS OF MOTOR PINICM KETS. LA8 TESTS AT KALSI HAD INDICATED THAT KEYS WITH HARDNESS 1018 COULD FAIL OUTSIDE THE PARAMETERS SPECIFIED BY LIMITORQUE IN PREVIOUS MAINTENANCE COMMUNICATIONS. Cope 40NWEALTH EDISON FINAL REPORT STATES "AISI TYPE 1018 KEYS ARE QUALIFIED FOR USE IN LIMITORQUE ACTUATORS WITH THE EXCEPil0NS NOTED BY LIMITORQUE
... MOTOR PINION KEYS SHOULD BE INSTALLED IN ACCORDANCE WITH LIMITORQUE GUIDELINES PROVIDED IN MAINTENANCE UPDATE 89-01."
THUS, NO DEFECT EXISTS. NONETHELESS, TMIS ISSUE WAS FOLLOWED UP UNDER PART 21 LOG 894285 AND CLOSED OUT 'JITH A MENTitm DF THE POTENTIAL PROBLEM IN IN 94-10. NO FURTHER ACTION.
9608120083 LIMITORQUE GREENE T. Start torque .:: high tenperature. Related Pt21 reports: 96890 12/31/%
Pt21 93472 Accessno 9308030149 Closed by issuance of IN 93-74 DUQUESNE LIGHT CD REPORTS THE!R ANALYSIS OF VALVE ACTUATORS RELATIVE TO PT 21 FROM LIMITORQUE ON DECREASES OF MOTOR STARTING TOR QUE WITM INCREASING TEMP.
Pt21 93277 Accessno 9306010023 Closed by issuance of IN 93-74 LIMITORQUE REPORTS LOCKED ROTOR TORQUE / AMPERAGE FOR REllANCE 3PH ASE VALVE ACTUATOR MOTORS WILL VARY WITH MOTOR TEMPERATURE; VALU ES DECREASE AS MOTOR TEMP INCREASES.
PERCENT CHANGE IN TEMP RAN GE OF 25C 10180C GIVEN.
Pt21 93321 Accessno 9308030372 closed by issuance of IN 93-74 B&W NUCLEAR TECH REPORTS THAT LIMITORQUE VALVE ACTUATORS AFFECTED BY INCREASED TEMP WERE SUPPLIED TO B&W DESIGNED PLANTS AND OTHERS. ALL WILL BE NOTIFIED.
ETS-23 am 4 01/17/97
I i PCAT M FOLLOW-UP ASSIGNMEN7S SORT > Plant Name QUERY >
t CSSIGNMENT CLOSING PART21 EVENT DE REPORT g g AS$!GNED TO SUBJECT (Event Description) tuggR g 03/22/95 28499 05/07/95 LIMITORQUE CORP. TAPPERT J. Wrong type of grease seat in limitorque actuators. (Buna-n 95057 OTN i seat rated for 210 to 250 F instead of viton seals rated for '
450 to 600 F) 8ma-N could f ait at 340 F.
08/09/96 0 MAGNE-BLAST /FITZPATRI SKEEN D. PART 21 LOG #96-311 - REFERRAL FROM AE00 LER REVIEW 96311 IDELTIFIED PART 21 INVOCATION FUR REPORT OF PROBLEM WITH CONTACT RESISTANCE ON MAGNE-8LAST OREAKERS IN SERVICE AT FITZPATRICK. MIGN RESISTANCE IN CLOSE COIL CIRCUIT RESULTED IN FAILURE TO START FOR RHRSW PUMPS A AND C. SAME EVENT AS PREVIOUSLY AS$1GNED IN EN#30149. 3 03/10/95 28456 04/20/95 MAINE YANKEE 1 CARTER J. THE LICENSEE IDENTIFIED EVIDENCE OF CRACKING IN GE TYPE SOM 95060 OTM !
CONTROL SWITCHES BOTH IN USE AND IN STOCK.
07/03/95 0 07/12/95 MAINE YANKEE 1 KOSHY T. Multiple 480V breaker trips casued by electrcnic trip 95133 OTH devices (RMS-9 supplied by GE).
06/30/95 28997 MCGUIRE 2 BENNER E. APPARENT DESIGN DEFICIENCY CAUSES FAILURE OF TURBO CHARGERS 95158 E01 ON BOTH UNIT 2 EDGS.
10/01/% 31009 11/29/96 MCGUIRE/0CONEE 1,2/1, KOTZALAS M. GRINNELL $NU88ERS QUALIFIED TO ENVIRONMENTAL CONDITIONS 96530 i DIFFERENT FROM ACCIDENT CONDITIONS.
10/01/96 0 11/01/96 MILLSTONE 1 TAPPERT J. On instattation of FairtW;nks Morse eds tower connecting rod, 96510 OTN ,
fomd that serial nu4ers on rod and its cap did not metch.
11/25/ % 31371 MILLSTONE 3 SKEEN D. PART 21 96800 - MILLSTC*tE REPORTS CRACKS IN BRASS FERRULES 96800 OF VARIOUS FUSES. FUSES FUNCTIONED WHEN TESTED, BUT DID NOT REMAIN INTACT. CONCERN IS GENERAft0N OF DEBRIS THAT COULD AFFECT hEARBY CIRCUITS.
12/04/96 9609120078 MILLSTONE 1 TAPPERT J. ON INSTALLATION OF FAIRBANKS MORSE EDG LOWER CONNECTING ROD, % 510 FOUND THAT SERIAL NUMBERS ON ROD AND ITS CAP DID NOT MATCH.
05/30/ % 0 MKM POWER SYSTEMS / PEE WANG E. PART 21 LOG #96291 - COOPER REPORTS A PROBLEM WITH VOLTAGE 96291 ADJUST POTENTIOMETER ON PEE 8LES VOLTAGE REGULATOR DUE TO -
FOREIGN MATERIAL.
05/02/95 9503100006 05/05/95 MKW POWER SYSTEMS WANG E. THIS PIECE OF CORRESPONDENCE DESCRISES A PROBLEM WITH POTTER 95095 BRUMFIELD RELAY #R10-E3286-2 USED IN CSD BATTERY CHARGERS.
ETS-23 Page:35 01/17/97 I
_...a._. _ ~ . _ - . - - - - . - - - - . - - - ..m----- - - _ .. .- -- - -.- --. .- - - -- - .-
I
- t !
PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
i CLOSING PART21 EVENT ASSIGNMEOT DE REPORT 9ATg g ASSIGNED TO SUBJECT (Event Description) -
IRMER M 0 07/26/95 MKW POWER SYSTEMS SKEEN D. IN AN INTERIM REPORT (LOG #95122, ISSUE NUMBER 95010) MKW 95122 OTN 5 06/08/95 POWER SYSTEMS REr0RTS THAT SQUARE D CLASS 8501 TYPE KPD !
RELAYS MAY HAVE CERTAIN CONTACTS SEEING SERVICE THAT EXCEEDS CAPACITY. THESE RELAYS ARE USED IN DIESEL GENERATOR CONTROL ;
PANELS SUPPLIED BY MKW. RELAYS MAVE GENERALLY SEEN EXTENDED ;
SERVICE WITHOUT PROBLEM, BUT CONTACTS USED BY THE EQUIPMENT j PURCHASER FOR AUXILIARY PURPOSES SUCH AS DG CIRCUIT BREAKER CLOSE, DG CIRCUIT BREACR TRIP, 86 LOCKCRJT RELAY TRIP MAY BE .
OVERSTRESSED SINCE CURRENLY SPECIFIED CAPACITY IS LESS THAN THAT ORIGINALLY SPECIFIED TO CUSTOMERS. PolNT BEACH ;
CONTACTED MKW WHEN THEY SURNED UP A CONTACT AND INITIATED i THE PART 21 CONCERN.
l 0 08/10/95 MKW POWER SYSTEMS WANG E. PART 21 LOG #95-123 - ISSUE NUMBER 95011 - MKW POWER SYSTEMS 95123 GEN 06/09/95 SUPPLIED TURKEY POINT WITH SEVERAL GENERAL ELECTRIC HEA63 LOCKOUT RELAYS, APPLICATION NOT SPECIFIED. THE RELAYS IN QUESTION WERE SUBJECT TO A MANUFACTURING DEFECT OF RANDOM NATURE (WINDOW OF OPPORTUNITY 1990 - 1996) THAT RESULTED IN ,
A SHAFT BEING CUT TOG SHORT. THIS IN TURN CAN CAUSE BINDING WHICH APPARENTLY HAPPENED IN ONE CASE AT TURKEY POINT. ONLY RELAYS WITH ELECTRIC RESET COULD HAVE THE PROBLEM. GE HAS !
SENT A SERVICE LETTER TO ALL THEIR CUSTOMERS, INCLUDING MKW WHICH GENERATED THE LOGGED CORRESPONDENCE. .
06/13/95 MKW POWER SYSTEMS WANG E. REPEAT OF #95-123 AS RECEIVED AGAINST TURKEY POINT DOCKET 95124 06/09/95 9505090038 ,
THROUGH RIDS. MKW POWER SYSTEMS SUPPLIED TURKEY POINT WITH SEVERAL GENERAL ELECTRIC HEA63 LOCKOUT RELAYS, APPLICATION i NOT SPECIFIED. THE RELAYS IN QUESTION WERE SUBJECT TO A MANUFACTURING DEFECT OF RANDOM NATURE (WINDOW OF OPPORTUNITY j 1990 - 1994) THAT RESULTED IN A SHAFT BEING CUT TOO SHORT. [
THIS IN TURN CAN CAUSE BINDING WHICH APPARENTLY HAPPENED IN ONE CASE AT TURKEY POINT. ONLY RELAYS WITH ELECTRIC RESET !
COULD HAVE THE PROBLEM. GE MAS SENT A SERVICE LETTER TO ALL !
THEIR CUSTOMERS, INCLUDING MKW WHICH GENERATED THE LOGGED CORRESPONDENCE.
r i
I
' Page:36 01/17/97 l ETS-23 t
s
PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
PART21 EVENT CLOSING ASSIGNMEDV DATE REPORT DATE VENDOR ASSIGNED TO SUBJECT (Event Description) NympgR g WANG E. PART 21 LOG #96290 - MKW POWER SYSTEMS REPORTS A POTENTIAL 96200 OTH 04/16/ % 9603270295 05/30/ % MKW POWER SYSTEMS DEFECT WITH THE VOLTAGE ADJUST POTENTIOMETER USED ON THE NEI PEEBLES (PORTEC) VOLTAGE REGULATORS. PROBLEM BROUGHT TO THEIR ATTENTION BY TURKEY POINT. INVESTIGATION COMPLETED, PROBLEM INVOLVES DEBRIS ON THE WIPER ARM THAT AFFECTS PERFORMANCE. HOWEVER, THE POT IS USED FOR A ONE-TIME ADJUST AT INITIAL INSTALLATION, AND MANY HAVE OPERATED WITHOUT PROBLEM FOR YEARS. THE REPLACEMENT POT IS SEALED AND LESS SUSCEPTIBLE TO CONTAMINATION. MKW WILL NOTIFY ALL CUSTOMERS WITH NEI VOLTAGE REGULATORS ABOUT THIS PROBLEM.
03/22/95 MKW POWER SYSTEMS, IN WANG E. MKW POWER SYSTEMS RECEIVED NOTIFICATION ON 2/27/95 FROM C&D 95058 OTH 03/10/95 H-95-0073 CHARTER POWER SUSTEMS ABOUT A 10CFR21 REPORTED MECHANICAL DEFECT IN THE LATCHING MECHANISM OF POTTER & BRUMFIELD #R10-E3286-2 RELAYS (C&D #JR-461-E).
30475 05/30/% MKW POWER SYSTEMS / PEE WANG E. PART 21 LOG #96292- MKW REPORTS A PROELEM WITH VOLTAGE 96292 05/29/ %
ADJUST POTENTIOMETER ON PEEBLES VOLTAGE REGULATOR DUE TO FOREIGN MATERIAL.
30322 MSD INC./STRUTHERS-DU HODGE V. PART 21 LOG #96370 - MSD INC. RfPORTS THAT A QUANTITY OF %370 05/29/96 STRUTHERS-DUNN TYPE 236ABX135NE TIME DELAY RELAYS BUILT IN 1983 COTAIN 39 GEUGE ColLS VICE 43 GAUGE COILS. ONE FAILURE TO DATE DUE TO OVERHEATING. NINE RELAYS FOUND, ALL AT PLANT HATCH. ALL ARE DATE CODED 8335.
0 MSD INC./STRUTHERS-DU HODGE V. PART 21 LOG #96371 - MSD INC. REPORTS THAT A QUANTITY OF %371 05/29/96 STRUTHERS-DUNN TYPE 236ABX135NE TIME DELAY RELAYS BUILT IN 1983 COTAIN 39 GEUGE ColLS VICE 43 GAUGE COILS. ONE FAILURE TO DATE DUE TO OVERHEATING. NINE RELAYS FOUND, ALL AT PLANT HATCH. ALL ARE DATE CODED 8335.
28285 02/06/95 MULTIPLE DENNIG R. COOPER, LASALLE, DRESDEN AND QUAD CITIES (TO DATE) HAVE 95030 02/01/95 FOUND THAT CONTRARY TO COMMITMENTS AND FSAR THE TIP BALL VALVES WILL REOPEN WITHOUT DELIBERATE ACTION IF 1. THEY RECEIVE AN TSOLAft04 SIGNAL TO CLOSE, 2. THE SIGNAL IS PRESENT, AND 3. THE VALVES WERE IN THE OPEN POSITION PRIOR TO THE ISOLATION SIGNAL.
H-95-0059 02/22/95 MULTIPLE DENNIG R. COOPER BESSEMER PROVIDES ADDITIONAL INFORMATION ON PREVIOUS 95048 02/22/95 REPORT RE MASTER POWER CONNECTING RODS.
Page:37 01/17/97 ETS-23
t
- PART 21 FOLLOW-UP ESSIGNMENTS SORT > Plant Name QUERY >
PART21 EVENT s.SSIGNME T CLOSING VENDOR AS$1GNED TO SUBJECT (Event Description) MIAISER g DE REPORT DATE MULTIPLE GREENE T. WESTINGHOUSE, SARGENT & LUNDY, AND COMMONWEALTH EDISON % 140 12/30/% 9512290269 ANALYSIS ASSUMPTIONS WRONG FOR REACTOR WATER STORAGE TANKS.
0 12/07/95 N/A DENNIG R. PART 21 LOG #95-222: CORRESPONDENCE IS NOT A PART 21 95222 12/03/95 ALTHOUGH INDICATED AS SUCH BY RIDS. ITEM RESPONDS TO A REQUEST FOR COMMENTS ON A PROPOSED IN 04 ASCO SOLENOID VALVES. NO ACTION REQUIRED.
30837 09/19/96 NAK ENGINEERING / BRUNS TAPPERT J. PART 21 LOG #96710 - NAK ENGINEERING REPORTS A PROBLEM WITH M 710 08/16/ %
NORD8 ERG MODEL FS1316HSC D/G AFFECTING FUEL LINE ASSEMBLY SUPPLIED TO BRUNSWICK AND MCGU!RE. INADEQUATE CRIMPING OF FERRULE SLEEVE.
28304 02/01/95 NINE MILE POINT 2 CARTER J. UE WAS DECLARED DUE TO INOPERABILITY OF DIV 1 AND DIV 2 95039 EOI 01/31/95 DIESELS. DIV 1 DIESEL WAS UNDERGOING CORRECTIVE MAINTENANCE DUE TO GOVERNOR OVERHEATING AND CONTROL PR00LEMS. WHEN THE OTHER DIESEL WAS STARTED AS PART OF THE TROUBLESHOOTING EFFORT (FOR COMPARISON PURPOSES) IT WOULDN'T TRIP ON NORMAL TRIP SIGNAL. THIS MADE THE Div 2 DIESEL TECHNICALLY INOPERABLE BUT AVAILABLE.
1-95-0020 02/22/95 NINE MILE POINT 1 DENNIG R. THE PLANT COMMENCED A NORMAL PLAMT SHUTDOWN AFTER 95046 02/22/95 l DISCOVERING THAT 3 0F 8 AGASTAT RELAYS IN POWER SUPPLIES FOR '
THE ANALOG TRIP SYSTEM WERE NOT FUNCT10NING. THESE RELAYS PROVIDE ANNUNCIATION UPON POWER SUPPLY FAILURE. THESE l RELAYS ARE NORMALLY ENERGIZED AND WERE INSTALLED CIRCA 1980 6 (24 VDC RELAYS MODEL FGPBC750). LICENSEE STATES THAT AGING AND CABINET TEMPERATURE WERE LIKELY CAUSES OF FAILURE.
9510310412 NUCLEAR CONTAINERS NMSS TRANSPORTATION OVERPACK DEFECTS MODEL UX-30. 95223 NMS 03/04/ %
01/15/97 NUCLETRON-OLDELFT NMSS MEDICAL TREATMENT CPU BOARD. 96330 12/04/ % 9603130277 9601300209 05/20/96 NUMERICAL APPLICATION WANG E. PT21 #96-210 96210 02/15/ %
NUMERICAL APPLICATIONS REPORTS A PROBLEM WITH VER$10NS OF GOTHIC AND FATHOMS CODES WHICH ARE USED FOR CONTAINMENT AND GENERAL THERMAL HYDRAULIC ANALYSIS.
H-95-0018 01/31/95 NUTHERM INTERNATIONAL GOODWIN E. FAILURES OF CAPACITORS IN NUTHERM INVERTERS 95013 01/26/95 Page:38 01/17/97 ETS-23
m__ .
- m _ _ _ _ . . . __ __ .
I PA27 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
ASSIGtWeENT CLOSING PART21 EVENT DAVE REPORT QAll VENDOR ASSIGNED TO SUBJECT (Event Description) NUESER M 02/22/95 H-95-0055 NUTHERM INTERNATIONAL FIELDS N. Potential failure of NUTHERM capacitors 95045 OTH 01/23/95 H-95-0011 05/18/95 OCONEE 2 CAMPBELL N. DUKE POWER /0CONEE 2 REPORTS LEAKAGE OF WATER FROM AUTO 95008 OTH INITIATION PRESSURE SWITCH FOR EMERGENCY FW PUMP. SWITCH IS CUSTOM CONTROL SENSOR MODEL #604G25. CONTACTS SHORTED OUT AND PREVENTED PUMP OPERATION. ALL SWITCHES TO BE IDENTIFIED AND REPLACED.
09/30/95 H-95-0040 11/18/96 OCONEE 1 KOSHY T. STATIC-0-RING PRESSURE SWITCHES PERFORMING OUTSIDE THE 95031 EDI EXPECTED ACCURACY.
12/04/96 9512180157 01/15/97 OMNiiRON NMSS OMNITRON AFTERLOADER SOFTWARE 96090 NMS 01/18/95 4-94-0116 05/31/95 PALO VERDE 2 TAPPERT J. AT&T BATTERIES SHOWING A DECLINE IN CAPACITY WITHIN THE 95083 E0I FIRST TWO FUEL CYCLES.
02/20/95 H-95-0072 06/07/95 PEAK TECHNICAL SERVIC FIELDS N. This item is followed up under the report submitted from 95056 OTH salem 28330. Information Notices and continuing follow ws will be tracked under 28330. This follow w item is only to address the response to Peak Technical Services.
01/26/95 H-95-0026 03/07/95 PILGRIM 1 FIELDS N. WRONG TYPE AK50 CIRCUlf BREAKERS SUPPLIED 95021 OTH 08/07/95 29096 08/15/95 POTTER & BRUMFIELD HUNEMULLER N. PART 21 LOG #95173 - 50.72 VERSION OF PREVIOUS REPORT ON 95173 GEN DAMAGE TO CONTACT ARMS IN A SPECIFIC LOT OF MODEL 5095 MOTOR DRIVEN RELATS. REPORT FROM SAN ONOFRE WHERE RELAYS WERE INSTALLED IN VARIOUS APPLICATIONS.
08/07/95 0 08/15/95 POTTER & BRUMFIELD HUNEMULLER N. PART 21 LOG #95174 - FAX FROM SAN ONCFRE RE: PREVIOUS REPORT 95174 ON DAMAGE TO CONTACT ARMS IN A SPECIFIC LOT OF MODEL 5095 MOTOR DRIVEN RELAYS. REPORT FROM SAN ONOFRE WHERE RELAYS WERE INSTALLED IN VARIOUS APPLICATIONS.
OF/10/95 29096 07/26/95 POTTER BRUMFIELD HUNEMULLER N. PART 21 LOG #95155 - POTTER & BRUMFIELD ADVISES THE NRC OF 95155 GEN LETTERS SENT TO CUSTOMERS RE: POSSIBLE INTERNAL DAMAGE TO MOVABLE ARMS AND REDUCED LIFE ON m R RELAYS. THE ORIGIN OF l THE PROBLEM AND THE NATURE OF THE DEFECT ARE NOT PROVIDED.
01/23/95 H-95-0010 01/23/95 PRAIRIE ISLAND 1,2 BENEDICT R. CRANE VALVE FAILURr- 95007 r
I ETS-23 Page:39 01/17/97
- _ . _ _ _ . ______ __ ___ _ ___ _ _ _ _ _ _ _ _ . _ _ _ _ . _ _ _ _ - _ . _ _ _ w. -.. _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _____m___ _ _ _ _ _ _ _ _ _ _ _ _ .
.. . - . . . ,. . - - ~_ - . - - - - . - . . . _. . . _ _
I PCRT 21 FOLLOW-UP ASSIGNMECT3 SORT > Plant Name QUERT>
l ClostWG PART21 EVENT ,
ASSIGNMEOT g REPORT g VENDOR ASSIGNED TO SUBJECT (Event Description) NyMggR g 30774 QUANEX/ CONS POWER SUP PETRONE C. PART 21 LOG #96650 - EN#30774 NOTIFIES THAT ONE LENGTN OF 96650 08/08/96 PIPE IN AN ORDER To CONSOLIDATED POWER SUPPLY FR(M QUANEX WAS NOT AS SPECIFIED, I.E. WAS A335 P22 VICE SA-106 GRADE B.
PART 21 LOG #96651 - LETTER FROM CONSOLIDATED POWER SUPPLY To QUANEX REPORTING ON STATUS OF INVESTIGATION OF POSSIBLE PROBLEM WITN PIPE SUPPLIED BY QUANEX. (ACCES$10N
- 9607240138) 27892 12/21/94 RIVER BEND 1 HUNEMULLER N. CONTROL ROD INSERTION LINES WERE FOUND LEAKING DURING COLD 95012 E01 10/13/94 SHUTDOWN INSPECTION. ONE LINE MAD A THROUGH WALL CRACK, ONE OTHER HAD A THROUGH WALL INDICATION, AND FOUR OTHERS HAD LINEAR INDICATIONS.
H-95-0042 02/01/95 RIVER BEND 1 GOODWIN E. NotSE IN ROSEMOUNT MODEL 1152 TRANSMITTERS. 95033 02/09/95 9412200148 05/04/95 filVER BEND 1 KOSHY T. Binding of turbine governor valve during an emergency 95033 03/24/95 demand.
RONAN NMSS 96030 NMS 02/27/96 9512050272 9503220185 05/18/95 ROSEMOUNT KOSHY T. Hydrogen permeation through Monet alloy 400 incorrectly used 95088 05/1G/95 as isolati . vj diaphram.
SKEEN D. PART 21 LOG #95150 - The licensee reported that the 95150 EDI t 08/08/95 28993 04/16/% ROSEMOUNT Rosemount model 1154SH9 pressure transmitters exhibited a l' tero shift between 6 and 15 psig white the expected shift -
uss 5.8psig. for a tem erature change from shutdown to normat operations. The problem was also reported in a faxed letter referenced in the "other report" above.
SKEEN D. PART 21 LOG #95171, ISSUE v95025 - ROSEMOUNT INDICATED 95171 GEN 08/07/95 9507200385 08/22/95 ROSEM0tlNT INCORRECT 0-RING IN LATEST REVISION TO MANUAL 4235 FOR MODEL 1152 NUCLEAR QUALIFIED TRANSMITTERS DATED OCTOBER 1992. IN PARTICULAR, RING SPECIFIED FOR MODEL 1152HP WAS NOT OF PROPER HARDNESS FOR HIGH PRESSURE APPLICATIONS. MANUAL IS BEING REVISED, CUSTOMERS NOTIFIED. IMPACT OF USING SOFTER RING CANNOT BE ASSESSED BT ROSEMOUNT SINCE PRECISE l APPLICATIONS NOT KNOWN.
i Page:40 otfj7f97 ETS-23 t
I
- PART 21 FOLLOW-UP CS$!GNMEDVS SORT > Plant Name QUERY >
OSSIGNMENT CLOSING PART21 EVENT g REPORT E VENDOR ASSIGNED TO SUBJECT (Event Description) Nt.MSER g 08/15/95 0 08/16/95 ROSEMOUNT KOSHY T. This document addresses Rosemount andel 1154SN9 with 95154 OTN excessive drift from temperature variation. This problem is being followed to under 95150 and EN 28993. This is a hard copy of the previously faxed information.
12/06/95 0 ROSEMOUNT SKEEN D. PART 21 LOG #95-227: ROSEMOUNT REPORTS A POTENTIAL 95227 INTERACTION BETWEEN DC-704 FILL FLUID AND RANDO HD-46 MACHINE FLUID RESIDUE LOCATED ON THE REMOTE SEAL HOUSING OF THE MODEL 1159 REMOTE SEAL SYSTEM. NO NUCLEAR FAILURES, ONE COMMERCIAL NON-NUCLEAR FAILURE.
12/06/95 0 12/12/95 ROSEMOUNT SKEEN D. PART 21 LOG #95-224: ROSEMOUNT REPORTS THAT PROBLEM WITH 95224 MANUAL CITING THE WRONG REPLACEMENT PART FOR MODEL 1152HP PROCESS 0-RING APPLIES TO ANOTHER EARLIER MANUAL. FIX IS THE SAME AS DISCUSSED IN PART 21 LOG #95-171, PREVIOUSLY CLOSED OUT IN ETS DATED 8/7/95. NO ADDITIONAL ACTION NEEDED.
01/29/96 0 04/17/ % ROSEMOUNT SKEEN D. MODEL 1154SH9 TRANSMITTER DOES NOT MEET PUBLISHED 96080 E01 SPECIFICATIONS FOR AMBIENT TEMPERATURE EFFECT FOR CERTAIN CALIBRATED RANGES. (MODEL 1154 IS THE SUBJECT OF OTHER PART 21 NOTIFICATIONS FOR VARIOUS PROBLEMS - 95073, 95088, 95150, 95154, AND 95227.)
9507030139 06/27/95 ROSEMOUNT SKEEN D. 95151 06/27/95 05/13/96 9511020336 05/13/ % ROSEMOUNT SKEEN D. PART 21 95-215: ROSEN0UNT REPORTS THAT PROBLEM WITH MANUAL 95215 CITING THE WRONG REPLACEMENT PART FOR MODEL 1152HP PROCESS O-RING APPLIES TO ANOTHER EARLIER MANUAL. FIX IS THE SAME AS DISCUSSED IN PART 21 LOG #95-171. NO ADD 11IONAL ACTION NEEDED.
28031 04/20/95 ROSEMOUNT NUCLEAR INS SKEEN D. ROSEMOUNT REPORT VIA PART 21 THAT CERTAIN MODELS OF PRESSURE 94287 OTH 11/1G/94 TRANSMITTERS WERE SUBJECT TO ZERO SHIFT AS A RESULT OF THE TESTING METHOD.
9610010294 ROSEMOUNT NUCLEAR INS KOTZALAS M. PART 21 #96580 - ROSEMOUNT NOTIFIES THAT SEVERAL MODEL 353C % 580 11/12/96 CONDUlf SEALS CONTAINED A SHORTED CONDITION THAT WAS NOT DETECTED BY TESTING AT THE FACTORY. IT WAS CAUGHT BE FUNCTIONAL TESTING AT THE CUSTOMER PRIOR TO USE. USERS OF 353C ANO 353C1 MODELS HAVE BEEN NOTIFIED.
Page:41 01/17/97 ETS-23
. 1 x_.- .. . . .- . ~ . . . - ~ - - . - n. .. ..n . - - . - - . ~ . - , ~ ~ - - - _ - . . .. . . . . . . _ . . . .
I
- PART 21 FOLLOW-UP ASSIGNMEDVS SORT > Plant Name QUERT>
f PART21 EVENT ,
QSSIGNMECT CLOSING '
M REPORT E D VEWOR ASSIGNED TO SUBJECT (Event Description) NLegER M 0 08/22/95 ROTO MCKENNA E. 94068 SOUTHERN CALIFORNIA EDISON PROVIDES ROOT CAUSE 94068 OTH 08/15/95 ANALYSIS REPORT FOR FAILURE OF ROTO TEST SWITCH BOLTS.
FAILURE ATTRIB To t!SE OF EXTRA HARD TTPE BRASS WHICH IS EXTREMELY BRITTLE. PROS ISOLATED TO ONE LOT. SEE LOG I
- 93470/93451/93445/94209.
27467 04/16/ % SACM DIESEL, INC. DENNIG R. PART 21 LOG #96260 - WARTSILA DIESEL REPORTS THAT SACM 96260 04/15/ %
DIESEL PARTS AND COMPONENTS K'.VE BEEN SOLD TO WARTS!LA SACM DIESEL (FRANCE). OTHER ADMINISTRATIVE INFO IS PROVIDED.
9503220185 06/16/95 SAINT LUCIE 1,2 KIRKPATRICK D. A resident inspector informed about a potential generic 95073 EDI i 03/01/95 problem with the Rosemotsit Transmitters. The problem was identified as gasing in the oil between the capacitor i plates.
Received Rosemount letter dated 3/21/95.
9608220045 12/06/% SAINT LUCIE 1,2 CARTER J. 23 0F 30 2" ANCHOR DARLING CHECK VALVES WERE FOUND TO HAVE A % 730 OTH l 08/29/96 '
DEFECT THAT COULD CAUSE THEM TO STICK OPEN. VALVE CASTING VOIDS CAN CAUSE PISTON TO BE COCKED. ,
I.
02/03/95 28330 04/18/95 SALEM 1,2 FIELDS N. Error in fuse location of SSPS leads to situation where 95042 SIG electrical short of a non-safety grade circuit could disable !
auto actuation of safety injection. Steam line break is potential initiator.
t H-95-0053 SALEM 1 KOSHT T. OUTPUT RELAY TEST SWITCH LOCATED ON THE SAFEGUARDS EQUIPMENT 95043 OTH ;
02/13/95 .
CABINET BECAME STUCK DURING SURVEILLANCE TESTING.
EXERCISING APPEARS TO HAVE SOLVED THE PROBLEM. THE AUTO TEST REVEALS THE PROBLEM.
t 02/01/95 SALEM 1,2 FIELDS N. 95132 02/01/95 9503090138 10/03/% SALEM 1,2 KOTZALAS M. PART 21 LOG #96480 - SALEM REPORTS A DEFECT IN A EDWARDS 96480 07/10/% 9508100226 VALVE MODEL 838TT CHEC% VALVE. NEW VALVE MAD LESS THAN 20%
CONTACT BETWEEN DISK AND SEAT. FINAL REPORT DUE 9/29/95 Page:42 01/17/97 r ETS-23
B i
+
PART 21 FOLLOW-UP ASSIGNMENTS i
SORT > Plant Name QUERY > ,
PART21 EVENT AS$1GNMECT CLOSING DATE VENDOR ASSIGNED TO SU8 JECT (Event Description) ggggt g EAll REPORT I
30850 SALEM 2 GREENE T. Pt21 Logho: % 740 M 740 09fo9f96 t-NEW ISSUE. A NUS Model OCA801 electronic isolation module that is used in the reactor protection system was found to ,
have unsoldered connections.
9609100105 SALEM 2 H0DGE V. A TERMINAL BLOCK SCREW FELL 00T ON PRE-INSTALLATION TESTING 96880 12/31/96 OF A 125 V DC BATTERY CHARGER. SUBSEQUENT INSPECTIONS OF OTHER NEWLY INSTALLED BATTERY CHARGERS AT UNIT 2 REVEALED NUMEROUS DISCREPANCIES, PROMPTING THE LICENSEE TO DECLARE THEM INOPERA8LE BECAUSE OF SEISMIC QUALIFICATION CONCERNS.
UNIT 1 WAS NOT AFFECTED (LER 50-311/ % -08)
SALEM 1,2 SKEEN D. THIS IS A NEW P21 NUMBER BUT IS PROBABLY RELATED TO SKEEN*s 96570 .
12/04/M 9608300075 ASSIGNMENT FOR EN 30758. THE LICENSEE CLAIMS THIS IS AN INTERIM REPORT RELATED TO A JUNE 25, 1996 IDENTIFICATION BU" EN 30758 IS DATED JULY 17, 1996. THE ONLY OTHER 50.72 THAT MIGHT BEAR ON THIS TOPIC IS EN 30688, DATED JUNE 27, 1996, BUT IT DOES NOT MENTION PROP CHIPS.
0 03/27/96 SAN ONOFRE 3 BIRMINGHAM J. AT SAN ONOFRE, CRACKS WERE FOUND IN ELECTRICAL CONTACT %130 02/14/96 FINGERS OF ABB 4KV BRE/AR TO LMNT COOLING WATER PUMP 3P026. NRC WAS NOTIFIED AND NOTIFICATION WAS ASSIGNED PT21-%130.
27973 07/14/95 SEABROOK 1 BENNER E. SAFETY SIGNIFICANCE OF DISABLING EMERGENCY SERVICE WATER 95084 OTH I 09/22/94 i PUMP FOR BOLT REPLACEMENT.
26803 03/27/95 SEABROOK 1 DENNIG R. DOCUMENT IS LER 443/94-003 FROM SEABROOK WHICH DISCUSSES 95066 03/24/95 MSSV SETPOINT ISSUE STEMMING FROM WESTINGHOUSE MSAL 94-01.
28206 01/12/95 SEQUOYAH 1,2 KOSHY T. NUMEROUS BREAKERS FOUND UNLATCHED. POTENTIAL FOR LACK OF 95003 OTH
- 01/12/95 CONTROL ON St VALVES.
i 9511080110 SHEPHERD NMSS 96020 NMS 02/27/96
+
0 SHOREHAM/VELAN VALVE HODGE V. SHORMAM REPORTS A DIFFICULTY WITH QA DOCUMENTATION FOR 96810 01/02/97 EQUIPMENT MANUFACTURED BY VELAN VALVE.
I ETS-23 Page:43 01f17f97 [
5
- PART 21 FOLLOW-UP ASSIGNMEDTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT ASSIGNMECT SUBJECT (Event Description) ggggg g g REPORT E D VENDOR ASSIGNED TO H-95-0084 $1EMENS FIELDS N. Moulded case breakers manufactured by Siemens causing 95059 03/24/95 premature failure identified as failure to close after trip or opening. Information received from Farwell & Hendricks Inc.
9503100009 05/18/95 SIEMENS KOSHY T. Moldad case circuit breakers that have reclosing problems. 95086 05/16/95 0 10/29/ % SIEMENS KDENICK S. Analysis code deficiencies identified in services offered by % 790 GEN 08/12/96 Siemens. Longterm follow up based on potential concerns.
PMs sending letters to 6 Licensees as it affected 50.46 analysis.
4-95-0039 07/06/95 SOUTH TEXAS 1 KDENICK S. Excessive tin smear on stand by Cooper Bessemer diesel 95077 OTH 05/15/95 generators. Five pistons rejected on one EDG and one piston rejected on another EDG. Verify if the vendoe actions are sufficient.
0 08/18/95 SUMMER 1 HUNEMULLER N. The short name for this issue is eccs ctrl. The description 94315 08/14/95 of the lead Part 21 report given in the old TOM dBase file is:
94315 F - SOUTH CAROLINA EEG/SU MER REPORTS FAILURE OF 27N DEGRADED VOLTAGE RELAY DUE TO FAILURE OF SU8 COMPONENT TIMER IC-US. RELAY CONTACTS 10 & 11 DID NOT CORRECTLY CHANGE STATE. MANUFACTURER PERFORMING FAILURE ANALYSIS. SEE LOG
- 95061.
Additional related Part 21 reports are described in the closeout section below.
31570 SUMMER SKEEN D. Sulfur-induced corrosion of #40 AWG copper strain gage lead 97010 01/93/97 wires and the beryllitse-copper link clip in Model 753 gage pressure electronic transmitters.
28561 SYNCOR NMSS Syncor ftne hood 95167 NMS 02/29/%
Page:44 01/1T/97 ETS-23
PART 21 FOLLOW-UP ASSIGNMECTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT i CSSIGNMECT DATE REPORT p_AH A VENDOR AS$1GNED TO SUBJECT (Event Description) ggga g 11/03/95 0 11/08/95 TELEDYNE BROWN ENGINE DENNIG R. PART 21 LOG #95189 - TELEDYNE BROWN RECEIVED A REPORT OF 95189 t OPERATIONAL PROBLEMS WHEN TESTING TWO MODEL 225 cmA-X CONTAINMENT MONITORING SYSTEMS AT NINE MILE PT 1. RELAY TBE/Al P/M R919 WAS FAILING WHEN SYSTEM WAS IN OPERAft0N AND ENCLOSURE DOOR WAS OPEN AND AMBIENT TEMP WAS NEAR SET POINT OF A THERM 0 SWITCH ASSOCIATED WITH THE RELAY. TELEDTNE DETERMINED THAT THE VIBRATION OF OPERAft0N PLUS OPERATION NEAR THE SET PotNT WAS RESPONSIBLE FR0 THE CHATTER THAT WAS HIGH-CYCLING THE RELAY AND CAUSING FAILURE . A FIX WAS DETERMINED AND CUSTOMERS (BOTH PWR AND BWR) HAVE BEEN NOTIFIED. FAILURE WOULD HAVE RESULTED IN LOSS OF POST-ACCIDENT ATMOSPHERE MONITORING CAPABILITY. VENDOR ACTIONS ARE SUFFICIENT.
i H-95-0022 TENNESSEE VALLEY AUTH HODGE V. TENNESSEE VALLEY AUTHORITY / WATTS BAR 1/2 REPORTS EQ FAILURE 95017 i 04/09/96 0F CATEGORY C (NOT REQD FOR LOCA) ELECTRICAL DEVICES MAY RESULT IN FAILURE OF CATEGORY A & B DEVICES. APPROP DESIGN I
CHANGES MADE.
H-95-0019 TENNESSEE VALLEY AUTH N00GE V. TENkESSEE VALLEY AUTHORITY /SEQUOYAH 1/2 PROVIDES FURTHER 95014 04/08/96 INFO REGARDING UNLATCHED MCCBs FOUND IN CABINETS. CONCERN j IS BREAKERS MAY BECOME INOP DURING SEISMIC EVENT. HOWEVER, ADDL EVAL BY LICENSEE t#DICATE NO PROS DUE TO CLOSE CABINET DOORS. SEE LOG #95-003.
9605210523 07/19/ % THOMAS & BETTS DENNIG R. PART 21 LOG #96490 - VENDOR REPORTS THAT WHILE NO FAILURES 96490 0F/SO/96 HAVE BEEN REPORTED, AGASTAT ETR "A" TIME RANGE RELAYS SHIPPED BETWEEN 8/14/95 AND 4/1/% WERE NOT TESTED CONTINUOUSLY ENERGIZED AND CONTAIN A CAPACITOR THAT MAY FAIL UNDER ABNORMAL TEMPERATURE CONDITIONS, I.E., ABOVE 156 DEGREES F IF CONTINUOUSLY ENERGlZED. ALL AFFECTED CUSTOMERS HAVE BEEN NOTIFIED.
9605070309 TROJAN ELECTRICAL SPLICES IN ELECTRICAL PENETRATION ASSEMBLIES. 96430 12/04/96 9505100118 TROXLER NMSS Troxter gauge weld 95127 NMS 02/29/96 Page:45 01/17/97 ETS-23 l
i i
PART 21 FOLLOW-UP ASSIGNMEOTS SORT > Plant Name QUERY >
ASSIGNMENT CLOSING PART21 EVENT g REPORT DATE VENDOR AS$1GNED TO SUBJECT (Event Description) g g 06/21/95 28721 07/06/95 TSI INC. SKEEN D. TSI INC. MANUFACTURES A LINE OF INSTRUMENTS FOR MEASURING 95120 OTH AIR FLOW. FOR CERTAIN MODELS THEY NOTED THEY HAD MADE CALIBRATION ERRORS OF 0 TO -2.5% THUS, AN INSTRUMENT READING OF 1000 FPM WOULD CORRESPOND TO AN ACTUAL FLOW OF 1020 FPM.
AS LONG AS THE LIMIT OF INTEREST IS A MINIMUM FLOW, THE ERROR WILL BE IN THE CONSERVATIVE DIRECTION. IF USED FOR MEASURING LEAKAGE FLOW, THE ERROR WOULD BE NONCONSERVATIVE.
04/25/95 9505300147 04/25/95 TSI INC. SKEEN D. 95121 08/16/96 30845 TSI INC. SKEEN D. PART 21 LOG #96720 - TSI REPORTS THAT CERTAIN MODELS OF % 720 ,
INSTRUMENTS ARE IMPACTED BY CONTAMINATED PRINTED CIRCUti !
BOARDS. IMPACT OF DEFECT CAN VARY, BUT IS MOST PRONOUNCED AT ELEVATED TEMPERATURES AND HUMIDITY. i 11/07/94 27980 12/20/94 TURKEY POINT 3,4 KOSHY T. Defect in sequencer software led to situation where EDG was 95105 SIG inoperable while sequencer was in certain self-test modes for periods of time over a year.
04/25/95 27980 05/11/95 TURKEY PolNT 3 KOSHY T. Self test feature of the Emergency load sequencer disabling 95106 GEN ECCS in certain sequencer modes.
02/23/95 1-95-0027 02/27/95 VERMONT YANKEE 1 CAMPBELL N. VERMONT YANKEE DISCOVERED A SPIRAL METAL FLAKE INSIDE AN 95054 UNIRRADIATED FUEL ASSEM8tY RECEIVED FROM GE.
04/13/95 9503020105 04/14/95 VICTOREEN DENNIG R. THIS IS A NOTIFICATION FROM VICTOREEN THAT THEY WERE 95090 SUPPLIED " NOISY" CIRCUlf BOARDS BY WESTRONICS. VICTOREEN WAS NOTIFIED BY WESTRONICS AS NOTED IN RELATED PART 21 LOG
- 95036 (CLOSED UNDER EN#28306). VICTOREEN STATES THAT l CIRCUIT BOARDS WERE ONLY USED IN CHART RECORDERS SENT TO ;
KOREA.
12/31/96 9611140064 V0GTLE 1,2 GREENE T. A FAILED SNUBBER BECAUSE OF A CRACKED INNER THRUST BEARING 96870 WOULD PROTECT ATTACHED PIPING BUT WOULD NOT RESET TO THE COLD POSITION. THUS THE PIPING WOULD BE STRESSED ON PLANT SHUTDOWN.
02/03/95 H-95-0046 02/17/95 WATTS BAR 1 K0ENICK S. CHECK VALVES USED IN VERI! CAL POSITION WOULD NOT CLOSE ON 95037 OTH REVERSE FLOW BECAUSE THEY LACK NECESSARY INTERNAL MODIFICATION.
ETS-23 Page:46 01/17/97
, _ _ _ _ _ . __ _m .
. . . . . _ . . - . _ . _ m_.. . _ . - . .m. . __ .._ . - m <__ _ _ .____.m
.. _m _ _ .
I 1
PART 21 FOLLOW-UP ASSIGNMEDTS SORT > Plant Name a
QUERY >
t CLOSING PART21 EVENT ASSIGNMEOT g R{ PORT g VENDOR ASSIGNED TO SUOJECT (Event Description) MDGER g 04/13/95 0 05/25/95 WATTS BAR 1 KDENICK S. TVA identified various types of conduit deficiencies d ich 95141 OTN include the following: Loose flex conduits, no conduit ID, minisam bend radius violations, inadequate support for marinite board, various support deficiencies, and separation violations.
0 07/19/95 WATTS BAR 1,2 KOSHY T. Contractors not fully actiering to the corrective action 95140 OTM 07/12/95 program for evaluating and reporting significant ;
deficiencies. This problem was previously addressed in v95014. ,
0 07/19/95 WATTS BAR 1,2 KOSHY T. 52 of the 65 incore thermo couples failed an insulation 95142 OTH 07/12/95 resistance test af ter hot furctional. !
0 06/03/96 WATTS BAR 1 DENNIG R. PART 21 LOG #95209 - LICENSEE REPORTS VIBRATION PROBLEM IN 95209 05/20/ %
AUX FEEDWATER SYSTEM DISCOVERED DURING HOT FUNCTIONAL TESTING.
WATTS BAR 1,2 DENNIG R. POTENTIAL DEFICIENCIES IN UNINSPECTED VENDOR-WIRED SAFETY- 95190 05/19/M 31366 RELATED ELECTRICAL PANELS.
24726 07/15/93 WESTINGHOUSE BENEDICT R. POTENTIAL INADEQUATE CORE COOLING FLOW CONDITION AS A RESULT 92269
, 12/11/92 i Of ISOLATION CF THE' RESIDUAL HEAT REMOVAL / LOW HEAD SAFETY INJECTION SYSTEM PUMPS FROM THE REACTOR COOLANT SYSTEM WHEN ATTEMPTING TO AllGN THEM TO THE RCS NOT LEGS. ,
i WEN P. PRESSURE REDUCING SLEEVE LOCKNUTS INSTALLED IN St PUMPS 95001 t 01/12/95 H-95-0001 04/07/95 WESTINGHOUSE COULD BE INFERIOR QUALITY. (PART 21 REPORT FROM i WESTINGHOUSE). [
28412 04/05/95 WESTINGHOUSE WEN P. Pressure reducing sleeve lock nut problem that could affect 95053 GEN ;
02/22/95 the performance of SI paps at various plants.
I
?
I i
L Page:47 01/17/97 E EVS-23
1 Pt.2T 21 FOLLOW-UP ASSIGNME%TS SORT > Plant Name QUERY >
PART21 EVENT CLOSING AS$1GNMEiT REPCRT RA ,,1 VENDOR ASSIGNED TO E 1 JECT (Event Description) g g DATE 9411280210 09/10/ % WESTINGHOUSE HODGE V. Tte safety significance of this problein is the potential 95016 GEN 07/20/95 decrease in analyzed safety margin against unstable crack g owth in a reactor coolant system toop. The maintenance of tie safety margin is needed to justify the removal ov pipe wnip restraint.
To avert interference with crossover leg piping, the support eksigner at a nuclear power plant arranged for the base of the front inside support colum for a reactor coolant pump to be placed 6-12 inches closer to the reactor pressure vestci than in the original design. Westinghouse determined that the resulting 2-5 degree tilt in the column decreased the vertical stiffness by a smatt amount. More significantly, however, Westinghouse determined that it might degrade the thermal expansion and loop loadings of the system. Westinghouse identified the affected plants:
Callaway, Seabrook, Watts 3ar 1, 2, Comanche Peak 1, 2, Sequoyah 1, 2, Wolf Creek, Farley 1, 2, Summer, Vogtle 1, 2, Harris DENNIG R. Pt21 LogNo: 96670 96670 OTH 09/09/96 9608120142 09/10/ % WESTINGHOUSE This Westinghouse Nuclear Advisory Service Letter (NASL) concerns containment fan cooter unit operation during a design basis accident. Westinghouse notes that this problem is being reviewed as a Part 21 report and that NRC received a licensee event report (LER) uruser docket number 50-275 (Diablo Canyon Unit 1) on this problem. The reference LER discusses this problem. Events Tracking System (ETS) assignmert (John Tappert) was opened on 0723% on a similar problem at Haddam Neck (Event Notification30772, dated 072296). The Events Assessment Panel directed issuance of an information notice (IN), closing the ETS assignment on 073096. A GENERIC LETTER HAS BEEN AUTHORIZED UNDER TAC eM96276. NO FURTHER ACTION NEEDED.
WESTINGHOUSE / SUMMER BENEDICT R. PART 21 LOG #96440 - EN FROM SUMMER STATING THAT WELDS 96440 TBD 06/05/ % 0 ORIGINALLY SPECIFIED AND PERFORMED BY WESTINGHOUSE ON COMPONENT COOLING WATER NOZ2LES FOR RCP SEAL INJECTION LINES ARE DEFECTIVE.
Page:48 01/17/97 ETS-23
PART 21 FOLLOW-UP ASSIGNMENTS SORT > Plant Name QUERY >
CLOSING PART21 EVENT t.SSIGNMExt DATE REPORT DATE VENp0R ASSIGNED TO SUBJECT (Event Description) NigggR g 0 WESTINGHOUSE / SUMMER BENEDICT R. PART 21 LOG #96441 - ENGINEER'S TECNNICAL WORK RECORO 96441 TBD 06/05/96 (WESTINGHOUSET) PROVIDING CAUSE AND CORRECTIVE ACTION FOR CONDITION IN EN#30507 STATING THAT WELDS ORIGINALLY SPECIFIED AND PERFORMED BY WESTINGHOUSF ON COMPONENT COOLING WATER NOZZLES FOR RCP SEAL INJECTION LINES ARE DEFECTIVE.
28306 02/06/95 WESTRONICS DENN!G R. WESTRONICS DISCOVERED THAT THE POSSIBILITY EXISTS THAT 95036 02/03/95 NONCONFORMING DIODES SUPPLIED AS SPARE PARTS MAY HAVE BEEN USED IN SIGNAL INPUT BOARDS FOR CHART RECORDERS. POTENTIALLY AFFECTED ARE: RIVER BEND, TURKEY POINT, FITZPATRICK, TA!WAN POWER CO. AND VICTOREEN (WHICH FRESUMABLY COULD HAVE INCORPORATED IN OTHER EQUIPMENT). ALL HAVE BEEN NOTIFIED.
THE AFFECT OF USING THE NONCONFORMING DIODES WOULD BE NOISY OPERATION AND CALIBRATION DRIFT.
0 04/26/% WESTRONICS DENNIG R. PART 21 LOG #96321 - WESTRONICS REPORTS DISCOVERY OF 96321 04/22/96 FIRMWARE BUG ASSOCIATED WITH SPECIFIC FACTORY SUPPLIED CONFIGURATIONS OF SERIES 3000C AND 3200C CHART RECORDERS.
MANUFACTURER DETERMINED IMAT ONLY SOUTHERN CALIFORNIA EDISON (SAN ONOFRE) HAD THE AFFECTED COMPONENTS, AND THEY WERE NOTIFIED. NO FURTHER ACTION. PART 21 LOG #96320 IS 50.72 FROM WESTRONICS WITH SAME INFO.
30153 04/26/ % WESTRONICS DENNIG R. PART 21 LOG #96320 - WESTRON!CS REPORTS DISCOVERY OF M320 04/22/96 FIRf8 WARE BUG ASSOCIATED WITH SPECIFIC FACTORY SUPPLIED CONFIGURATIONS OF SERIES 3000C AND 3200C CHART RECORDERS.
MANUFACTURER DETERMINED THAT ONLY SOUTHERN CALIFORNIA EDISON (SAN ONOFRE) HAD THE AFFECTED COMPONENTS, AND THEY WERE NOTIFIED.
30395 07/23/96 WM BEAUMONT HOSP. IMOB BRASS RING IN VIAL SHIELD CAME LOOSE, SPILLING 60 MCI Tc-99. 96410 NMS 05/03/96 03/15/95 4-95-0030 04/11/95 WOLF CREEK 1 K0ENICK S. Estimated core criticality was off through 1000pcm. 95065 OTH 30579 08/05/96 WOLF CREEK 1 CARTER J. PART 21 #96-066 96066 03/05/%
Page:49 01/17/97 ETS-23
. _ . _ _ _ _ _ _ _ _ _ _ __ . _ _ _ . _ _ _ - - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . - - _ - _ - _ _ _ _ _ _ - _ - _ _ _ _ _ _ _ _ _ _ _ _ . - _ _ _ _ _ _ _ - _ _ - - - - _ _ _ _ .. a
x PART 21 FOLLOW-D CSSIGNMENTS SORT > Plant Name ,
QUERY >
PART21 EVENT LSSIGNMEOT CLOSING g REPORT DATE g ASSIGNED TO SUBJECT (Event Deserfotion) g g 08/14/95 WYLE LA8 BIRMINGHAM J. PART 21 LOG #95-137. MINE MILE POINT SUOMITS A PART 21 95137 OTN 07/05/95 28853 INDICATING THAT THEY HAD RELIED ON A WYLE LAS REPORT ON SERVICE LIFE FOR AGASTAT GP RELAYS. REPORT STATED TO BE NONCONSERVATIVE. RELATED TO PART 21 95046, MR1-95-0020. THIS PART 21 PROVIDES LICENSEE'S ASSESSMENT OF REASON FOR PROBLEMS DISCUSSED IN 95046 (SEE ETS CLOSE0UT OF THIS ITEM). .
DETAILED REPORT IS PROVIDED UNDER PART 21 LOG #95138.
0 07/06/95 WYLE LA8 BIRMINGHAM J. NINE MILE POINT SUOMITS A PART 21 INDICATING THAT THEY HAD 95138 0F/05/95 RELIED ON A WYLE LAS REPORT ON SERVICE LIFE FOR AGASTAT GP RELAYS. REPORT STATED TO BE NONCONSERVATIVE.
BIRMINGHAM J. PART 21 LOG #95144 - RIDS COPY OF CORRESPONDENCE LOGGED As 95144 OF/13/95 0 07/31/95 WYLE LAB -
PART 21 LOG #95138 ALREADY AS$1GNED UNDER EN#28853. "
DEFICIENCY IN WYLE LA8 REPORT RE LIFE OF AGASTAT GP RELAYS.
07/31/95 WYLE LAB BIRMINGHAM J. PART 21 LOG #95153 - HARDCOPY OF VERBAL / FAX REPORT FROM 95153 0F/20/95 9507050075 NIAGARA MOHAWK RELATED TO DEFICIENT WYLE LAS REPORT RELIED ON FOR AGASTAT RELAY LIFETIME INFO. RELATED TO PART 21 LOG
- 95138, 95144. CLOSE0UT IN ETS UNDER ASSIGNMENT DATED 7/5/95.
l I
Page:50 01/17/97 TS-23
_ . . _ _ - . _ - _ _ - _ - _ _ _ _ _ - _ _ - _ _ _ . - _ - . _ _ _ _ - - _ _ _ - _ _ . - . -