ML19065A307: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 42: Line 42:
PUBLIC PROTECTION NOTIFICATION The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information or an information collection requirement unless the requesting document displays a currently valid Office of Management and Budget control number.
PUBLIC PROTECTION NOTIFICATION The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information or an information collection requirement unless the requesting document displays a currently valid Office of Management and Budget control number.


ML19065A307 OFFICE        RII/DRP      RII/DRP NAME          APatz        ABlamey DATE          02/28/2019    03/05/2019
ML19065A307 OFFICE        RII/DRP      RII/DRP NAME          APatz        ABlamey DATE          02/28/2019    03/05/2019 INFORMATION REQUEST FOR VOGTLE ELECTRIC GENERATING PLANT PROBLEM IDENTIFICATION AND RESOLUTION INSPECTION (APR 29 - MAY 3 AND MAY 13-17, 2019)
 
INFORMATION REQUEST FOR VOGTLE ELECTRIC GENERATING PLANT PROBLEM IDENTIFICATION AND RESOLUTION INSPECTION (APR 29 - MAY 3 AND MAY 13-17, 2019)
Note: Unless otherwise noted, the information requested below corresponds to documents generated since March 10, 2017. Please provide the requested documents in electronic format.
Note: Unless otherwise noted, the information requested below corresponds to documents generated since March 10, 2017. Please provide the requested documents in electronic format.
If the information is not available in electronic format, please contact the inspection team leader to coordinate other available methods to provide the information.
If the information is not available in electronic format, please contact the inspection team leader to coordinate other available methods to provide the information.

Latest revision as of 11:00, 2 February 2020

Notification of Inspection and Request for Information for NRC Problem Identification and Resolution Inspection
ML19065A307
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 03/06/2019
From: Alan Blamey
NRC/RGN-II, Division Reactor Projects II, NRC/RGN-II/DRP/RPB2
To: Myers D
Southern Nuclear Operating Co
Geanette D
References
Download: ML19065A307 (7)


Text

March 6, 2019 Mr. Darin Myers Vice President Southern Nuclear Operating Company, Inc.

Vogtle Electric Generating Plant 7821 River Road Waynesboro, GA 30830

SUBJECT:

VOGTLE ELECTRIC GENERATING PLANT - NOTIFICATION OF INSPECTION AND REQUEST FOR INFORMATION FOR NRC PROBLEM IDENTIFICATION AND RESOLUTION INSPECTION

Dear Mr. Myers:

The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC)

Region II staff will conduct a problem identification and resolution (PI&R) inspection at your Vogtle Electric Generating Plant, Units 1 and 2, during April 29 - May 3 and May 13 - 17, 2019.

The inspection team will be led by Mr. Andrew Patz, Resident Inspector. This inspection will be conducted in accordance with the baseline inspection procedure, 71152, Problem Identification and Resolution, issued February 26, 2015.

The biennial PI&R inspection and assessment of the licensees corrective action program (CAP) complements and expands upon the resident baseline inspections of routine daily screening of all corrective action program issues, quarterly focused issue reviews, and semiannual trend PI&R reviews.

On February 27, 2019, Mr. Patz discussed with Kevin Walden some details and expectations for the two weeks of onsite inspection.

The enclosure lists documents that will be needed prior to the inspection. Please have the referenced information available no later than April 15, 2019 unless otherwise requested in the enclosure. Contact Mr. Patz with any questions concerning the requested information. The inspectors will try to minimize your administrative burden by specifically identifying only those documents required for inspection preparation.

If additional documents are needed, they will be requested when identified. Prior to the onsite inspection, Mr. Patz will discuss with your staff the following inspection support administrative details: availability of knowledgeable plant engineering and licensing personnel to serve as points of contact during the inspection; method of tracking inspector requests during the inspection; access to licensee computers; working space; arrangements for site access; and other applicable information.

D. Myers 2 In accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding, of the NRCs Rules of Practice, a copy of this letter and its enclosure will be available electronically for public inspection in the NRCs Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Thank you for your cooperation in this matter. If you have any questions regarding the information requested or the inspection, please contact Mr. Patz at (404) 997-5153.

Sincerely,

/RA/

Alan J. Blamey, Chief Reactor Projects Branch 2 Division of Reactor Projects Docket Nos.: 50-424, 50-425 License Nos.: NPF-68, NPF-81

Enclosure:

Information Request for Vogtle PI&R Inspection cc: Distribution via ListServ PAPERWORK REDUCTION ACT STATEMENT This letter does not contain new or amended information collection requirements subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection requirements were approved by the Office of Management and Budget, control number 3150-0011.

PUBLIC PROTECTION NOTIFICATION The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information or an information collection requirement unless the requesting document displays a currently valid Office of Management and Budget control number.

ML19065A307 OFFICE RII/DRP RII/DRP NAME APatz ABlamey DATE 02/28/2019 03/05/2019 INFORMATION REQUEST FOR VOGTLE ELECTRIC GENERATING PLANT PROBLEM IDENTIFICATION AND RESOLUTION INSPECTION (APR 29 - MAY 3 AND MAY 13-17, 2019)

Note: Unless otherwise noted, the information requested below corresponds to documents generated since March 10, 2017. Please provide the requested documents in electronic format.

If the information is not available in electronic format, please contact the inspection team leader to coordinate other available methods to provide the information.

1. Copies of the corporate and site level procedures and sub-tier procedures associated with the corrective action program. This should include procedures related to:

a) Corrective action process b) Cause evaluations c) Operating experience program d) Employee concerns program e) Self-assessment program f) Maintenance rule program and implementing procedures g) Operability determination/functionality assessment process (IMC 0326) h) System health process or equivalent equipment reliability improvement programs i) Preventive maintenance deferral process j) Quality Assurance (App. B) audit procedures/checklists k) Quality Assurance (App. B) plan If any of the procedures requested above were revised after March 10, 2017, please provide (or have available) copies of all revisions during the onsite inspection.

2. List of top ten risk-significant systems, top ten risk-significant components for each one of the top ten risk-significant systems, and top ten risk-significant operator manual actions.

Please provide by April 8, 2019.

3. List of all condition reports initiated including the following information for each CR:

a) CR number b) Brief, but complete problem description c) Priority or level d) Affected system e) Affected component f) Responsible plant department g) CR completion status If possible, provide this list in a format compatible with spreadsheet software (example shown below).

CR # Problem Priority System Component Org Status CR001 A RHR Pump 2 RHR 2-RHR- ENG Open failed flow criteria PMP-A per SR 5.0.5.4 Enclosure

4. List of outstanding corrective actions including the following information for each action:

a) Corrective action number b) Corrective action type (e.g., corrective action to prevent recurrence, enhancement, maintenance rule evaluation, etc.)

c) Brief, but complete corrective action description d) Associated CR number e) Corrective action initiation date f) Number of extensions g) Corrective action due date h) Completion status If possible, provide this list in a format compatible with spreadsheet software (example shown below).

Corrective Type Description CR Initiation Extensions Due Status Action # Date Date 001 CAPR Revise CR0058 01/05/18 2 06/15/18 Awaiting Procedure review NGK-003-4585

5. List of all currently extended or overdue CRs, sorted by initiation date, with the following information:

a) CR number b) Priority or Significance c) CR title and short description

6. List of all CRs that have been voided, cancelled, or deleted. Please provide the following information for each CR:

a) CR number b) Brief, but complete problem description c) Reason voided, cancelled, or deleted

7. All operability evaluations/functionality assessments. Provide current list of all operable but degraded non-conforming (OBDN) items. Include CR number, brief description of the issue, initiation date, any compensatory actions, and expected resolution date.
8. List of corrective maintenance work orders and modifications for safety-related (SR) structures, systems and components and any work considered high risk. Please include the following information for each item:

a) WO number/modification number b) Brief, but complete work description c) Affected system and components d) Date of initiation e) Date of completion (if completed) f) Associated CR (if applicable) 2

If possible, provide this list in a format compatible with spreadsheet software (example shown below).

Work Description System Component Initiation Due Status CR #

Order # Date Date WO01345 Replace breaker SI 2A-SI-PMP, 01/05/18 03/15/18 Closed CR 2A-BKR-08-BB4 BKR-08-BB4 XXXX for 2A SI Pump.

9. Corrective action documents, including CRs with description of corrective actions, for all NRC findings and licensee-identified violations (LIVs). Please include a cross-reference linking NRC finding numbers and LIVs to appropriate CR numbers.
10. Corrective action documents, including CRs with description of corrective actions, for all licensee event reports (LERs) issued. Please include a cross reference linking LER number to appropriate CR number.
11. List of all NRC generic communications (e.g., Information Notices, Generic Letters, etc.) and industry operating experience (OE) documents (e.g., Part 21 reports, vendor information letters, information from other sites, etc.) evaluated by the site for applicability to the station, regardless of the determination of applicability. Please include the reference number (e.g.,

CR number) for the documents that evaluated the aforementioned OE information.

12. Copies of all quality assurance audits and/or assessments issued, including the last two audits/assessments of the corrective action program.
13. Copy of the most recent integrated plant trend report, departmental trend report(s), and corrective action trend report, including any human performance and equipment reliability trends.
14. Copy of the latest Corrective Action Program statistics, if available, such as the number of CRs initiated by department, human performance errors by department, and others as may be available.
15. Please provide a list of routine meetings involving the CAP to be held while team is onsite.
16. List of CRs related to equipment aging issues in the top ten risk-significant systems since April 2014 (e.g., system erosion and/or corrosion problems; electronic component aging or obsolescence of circuit boards, power supplies, relays, etc.; environmental qualification).

Please provide the following information for each CR:

a) CR number b) Priority c) CR problem description

17. If conducted, please provide any recent assessment(s) of the sites safety culture.
18. Copies of corrective action program documents related to cross-cutting issues (human performance, problem identification and resolution, and safety conscious work environment) identified via trending, self-assessments, safety review committee or other oversight methods 3
19. List of all root cause evaluations with a brief description.
20. Copy of the Probabilistic Risk Assessment importance measures report, if available.
21. System health reports, system design basis documents, maintenance rule (MR) status, applicable MR functions, MR evaluations, MR functional failures, and system description information upon notification of system selections.

4