ML071500010: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter:}} | {{#Wiki_filter:June 7, 2007Mr. William R. Campbell, Jr.Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 | ||
==SUBJECT:== | |||
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 AND WATTS BAR NUCLEARPLANT, UNIT 1 - NRC GENERIC LETTER 2006-01: STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NOS. MD0110, MD0111 AND MD0121)On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter(GL) 2006-01, "Steam Generator [SG] Tube Integrity and Associated Technical Specifications | |||
[TSs]," (Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity. By letter dated February 21, 2006 (ADAMS Accession No. ML060540116), Tennessee ValleyAuthority (TVA), the licensee for Sequoyah Nuclear Plant (SQN), Units 1 and 2, and the Watts Bar Nuclear Plant (WBN) Unit 1, submitted a response to GL 2006-01. The response stated that applications for changes to the TSs for SQN Units 1 and 2 and WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity had previously been submitted. | |||
These new TSs were modeled after Technical Specification Task Force (TSTF) Traveler, TSTF-449, "Steam Generator Tube Integrity," (ADAMS Accession No. ML051090200). The application for SQN Unit 1 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated August 31, 2005 (ADAMS Accession No. ML052500560). On February 23, 2006, the NRC staff issued Amendment No. 306 to the SQN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML060550100).The application for SQN Unit 2 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated February 15, 2006 (ADAMS Accession No. ML060600405). The original application was supplemented by letters dated August 7, 2006 (ADAMS Accession No. ML062280054), August 30, 2006 (ADAMS Accession No. ML062500211), November 30, 2006 (ADAMS Accession No. ML063390665), and April 2, 2007 (ADAMS Accession No. ML071010153). On May 22, 2007, the NRC staff issued Amendment No. 305 to the SQN Unit 2 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML071210013). | |||
W. R. Campbell, Jr.-2-The application for WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated December 15, 2005 (ADAMS Accession No. ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No. | |||
ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.Sincerely, /RA/Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket Nos. 50-327, 50-328 and 50-390 cc: See next page | |||
ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No. | |||
ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.Sincerely, /RA/Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket Nos. 50-327, 50-328 and 50-390 cc: See next pageDISTRIBUTION | |||
:PUBLICLPLII-2 r/fRidsNrrDorlLpl2-2RidsNrrPMBMoroney RidsNrrLACSolaRidsOgcRpRidsAcrsAcnwMailCenterRidsNrrDirsltsb RidsRgn2MailCenter KKarwoski, NRRRidsNrrDorlDprRidsNrrCsgbDBeaulieu, NRRADAMS ACCESSION NO: ML071500010OFFICELPL2-2/PMLPL2-2/LANRR/CSGB/BCLPL2-2/BCNAMEBMoroneyRSolaAHiserTBoyceDATE6/7/076/7/076 /06/07 6/7/07 Page 1 of 2William R. Campbell, Jr.SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:Mr. Ashok S. Bhatnagar Senior Vice President Nuclear Generation Development and Construction Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Preston D. Swafford Senior Vice President Nuclear Support Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Walter M. Justice II Interim Vice President Nuclear Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801Mr. Michael D. Skaggs, Site Vice PresidentWatts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381Mr. Randy Douet, Site Vice PresidentSequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000General CounselTennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902Mr. John C. Fornicola, ManagerNuclear Assurance Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801Mr. Robert H. Bryan, Jr., General ManagerLicensing and Industry Affairs Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Ms. Beth A. Wetzel, Manager Corporate Nuclear Licensing and Industry Affairs Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801Mr. Glenn W. Morris, ManagerLicensing and Industry Affairs Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000Mr. David A. Kulisek, Plant ManagerSequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000Senior Resident InspectorSequoyah Nuclear Plant U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, TN 37379County MayorHamilton County Courthouse Chattanooga, TN 37402-2801 Page 2 of 2William R. Campbell, Jr.SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:Mr. James D. Smith, Acting ManagerLicensing and Industry Affairs Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381Mr. Michael J. Lorek, Plant ManagerWatts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381Senior Resident InspectorWatts Bar Nuclear Plant U.S. Nuclear Regulatory Commission 1260 Nuclear Plant Road Spring City, TN 37381 County Executive 375 Church Street Suite 215 Dayton, TN 37321County Mayor P. O. Box 156 Decatur, TN 37322Mr. Lawrence E. Nanney, DirectorDivision of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532Ms. Ann P. Harris341 Swing Loop Road Rockwood, TN 37854}} |
Revision as of 00:11, 11 November 2018
ML071500010 | |
Person / Time | |
---|---|
Site: | Watts Bar, Sequoyah |
Issue date: | 06/07/2007 |
From: | Moroney B T NRC/NRR/ADRO/DORL/LPLII-2 |
To: | Campbell W R Tennessee Valley Authority |
Moroney B T, NRR/DORL, 415-3974 | |
References | |
TAC MD0110, TAC MD0111, TAC MD0121 | |
Download: ML071500010 (5) | |
Text
June 7, 2007Mr. William R. Campbell, Jr.Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 AND WATTS BAR NUCLEARPLANT, UNIT 1 - NRC GENERIC LETTER 2006-01: STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NOS. MD0110, MD0111 AND MD0121)On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter(GL) 2006-01, "Steam Generator [SG] Tube Integrity and Associated Technical Specifications
[TSs]," (Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity. By letter dated February 21, 2006 (ADAMS Accession No. ML060540116), Tennessee ValleyAuthority (TVA), the licensee for Sequoyah Nuclear Plant (SQN), Units 1 and 2, and the Watts Bar Nuclear Plant (WBN) Unit 1, submitted a response to GL 2006-01. The response stated that applications for changes to the TSs for SQN Units 1 and 2 and WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity had previously been submitted.
These new TSs were modeled after Technical Specification Task Force (TSTF) Traveler, TSTF-449, "Steam Generator Tube Integrity," (ADAMS Accession No. ML051090200). The application for SQN Unit 1 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated August 31, 2005 (ADAMS Accession No. ML052500560). On February 23, 2006, the NRC staff issued Amendment No. 306 to the SQN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML060550100).The application for SQN Unit 2 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated February 15, 2006 (ADAMS Accession No. ML060600405). The original application was supplemented by letters dated August 7, 2006 (ADAMS Accession No. ML062280054), August 30, 2006 (ADAMS Accession No. ML062500211), November 30, 2006 (ADAMS Accession No. ML063390665), and April 2, 2007 (ADAMS Accession No. ML071010153). On May 22, 2007, the NRC staff issued Amendment No. 305 to the SQN Unit 2 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML071210013).
W. R. Campbell, Jr.-2-The application for WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated December 15, 2005 (ADAMS Accession No. ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No.
ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.Sincerely, /RA/Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket Nos. 50-327, 50-328 and 50-390 cc: See next page
ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No.
ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.Sincerely, /RA/Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket Nos. 50-327, 50-328 and 50-390 cc: See next pageDISTRIBUTION
- PUBLICLPLII-2 r/fRidsNrrDorlLpl2-2RidsNrrPMBMoroney RidsNrrLACSolaRidsOgcRpRidsAcrsAcnwMailCenterRidsNrrDirsltsb RidsRgn2MailCenter KKarwoski, NRRRidsNrrDorlDprRidsNrrCsgbDBeaulieu, NRRADAMS ACCESSION NO: ML071500010OFFICELPL2-2/PMLPL2-2/LANRR/CSGB/BCLPL2-2/BCNAMEBMoroneyRSolaAHiserTBoyceDATE6/7/076/7/076 /06/07 6/7/07 Page 1 of 2William R. Campbell, Jr.SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:Mr. Ashok S. Bhatnagar Senior Vice President Nuclear Generation Development and Construction Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Preston D. Swafford Senior Vice President Nuclear Support Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Walter M. Justice II Interim Vice President Nuclear Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801Mr. Michael D. Skaggs, Site Vice PresidentWatts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381Mr. Randy Douet, Site Vice PresidentSequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000General CounselTennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902Mr. John C. Fornicola, ManagerNuclear Assurance Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801Mr. Robert H. Bryan, Jr., General ManagerLicensing and Industry Affairs Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Ms. Beth A. Wetzel, Manager Corporate Nuclear Licensing and Industry Affairs Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801Mr. Glenn W. Morris, ManagerLicensing and Industry Affairs Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000Mr. David A. Kulisek, Plant ManagerSequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000Senior Resident InspectorSequoyah Nuclear Plant U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, TN 37379County MayorHamilton County Courthouse Chattanooga, TN 37402-2801 Page 2 of 2William R. Campbell, Jr.SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:Mr. James D. Smith, Acting ManagerLicensing and Industry Affairs Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381Mr. Michael J. Lorek, Plant ManagerWatts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381Senior Resident InspectorWatts Bar Nuclear Plant U.S. Nuclear Regulatory Commission 1260 Nuclear Plant Road Spring City, TN 37381 County Executive 375 Church Street Suite 215 Dayton, TN 37321County Mayor P. O. Box 156 Decatur, TN 37322Mr. Lawrence E. Nanney, DirectorDivision of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532Ms. Ann P. Harris341 Swing Loop Road Rockwood, TN 37854