Revision as of 17:21, 1 April 2018
Similar Documents at Salem |
---|
Category:Letter
MONTHYEARIR 05000272/20244032024-09-25025 September 2024 and Salem Nuclear Generating Station, Units 1 and 2, Cybersecurity Inspection Report 05000354/2024403, 05000272/2024403, and 05000311/2024403 (Cover Letter Only) ML24267A1082024-09-23023 September 2024 Submittal of the Reactor Vessel Material Surveillance Program Capsule Technical Report IR 05000272/20244022024-09-23023 September 2024 and Salem Nuclear Generating Station, Units 1 and 2 - Security Baseline Inspection Report 05000354/2024402, 05000272/2024402, and 05000311/2024402 (Cover Letter Only) IR 05000272/20240052024-08-29029 August 2024 Updated Inspection Plan for Salem Nuclear Generating Station, Units 1 and 2 (Report 05000272/2024005 and 05000311/2024005) IR 05000272/20240022024-07-30030 July 2024 Integrated Inspection Report 05000272/2024002 and 05000311/2024002 LR-N24-0012, Application to Revise Technical Specifications and 10 CFR 50.12 Exemption Request to Implement Optimized ZIRLO Fuel Rod Cladding2024-07-24024 July 2024 Application to Revise Technical Specifications and 10 CFR 50.12 Exemption Request to Implement Optimized ZIRLO Fuel Rod Cladding ML24145A1772024-07-15015 July 2024 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Issuance of Amendment Nos. 236, 349, and 331 Modify Exclusion Area Boundary IR 05000272/20245012024-06-12012 June 2024 and Salem Nuclear Generating Station, Units 1 and 2 - Emergency Preparedness Biennial Exercise Inspection Report 05000354/2024501, 05000272/2024501 and 05000311/2024501 ML24099A1572024-05-29029 May 2024 Issuance of Amendment Nos. 348 and 330 Permanent Extension of Type a and Type C Containment Leak Rate Test Frequencies ML24150A0032024-05-28028 May 2024 Request for Exemptions from 10 CFR 50.82(a)(8)(i)(A) and 10 CFR 50.75(h)(1)(iv) and Proposed Amendment to the Decommissioning Trust Agreement LR-N24-0041, Stations, Revisions to Emergency Plan Document Nc EP-EP-ZZ-01102, Rev. 28, Emergency Coordinator Response2024-05-22022 May 2024 Stations, Revisions to Emergency Plan Document Nc EP-EP-ZZ-01102, Rev. 28, Emergency Coordinator Response IR 05000272/20240102024-05-16016 May 2024 Fire Protection Team Inspection Report 05000272/2024010 and 05000311/2024010 LR-N24-0038, Pressure Boundary Leakage Through a Reactor Coolant Pump Thermal Barrier Heat Exchanger2024-05-0909 May 2024 Pressure Boundary Leakage Through a Reactor Coolant Pump Thermal Barrier Heat Exchanger IR 05000272/20240012024-05-0707 May 2024 Integrated Inspection Report 05000272/2024001 and 05000311/2024001 LR-N24-0039, Steam Generator Tube Inspection Report - Twenty-ninth Refueling Outage2024-05-0606 May 2024 Steam Generator Tube Inspection Report - Twenty-ninth Refueling Outage LR-N24-0035, 2023 Annual Radiological Environmental Operating Report (AREOR)2024-04-30030 April 2024 2023 Annual Radiological Environmental Operating Report (AREOR) LR-N24-0034, 2023 Annual Radioactive Effluent Release Report (ARERR)2024-04-30030 April 2024 2023 Annual Radioactive Effluent Release Report (ARERR) LR-N24-0024, Response to Request for Additional Information Associated with License Amendment Request (LAR) to Modify the Salem and Hope Creek Exclusion Area Boundary2024-04-26026 April 2024 Response to Request for Additional Information Associated with License Amendment Request (LAR) to Modify the Salem and Hope Creek Exclusion Area Boundary LR-N24-0011, Supplemental Information to License Amendment Request (LAR) to Modify the Salem and Hope Creek Exclusion Area Boundary2024-04-0505 April 2024 Supplemental Information to License Amendment Request (LAR) to Modify the Salem and Hope Creek Exclusion Area Boundary IR 05000272/20240112024-04-0101 April 2024 and Salem Nuclear Generating Station, Units 1 and 2 - Plant Modification and Annual Problem Identification and Resolution Inspection Report 05000354/2024011, 05000272/2024011, and 05000311/2024011 LR-N24-0028, and Salem Generating Station - Notice of Intent to Pursue Subsequent License Renewal2024-03-28028 March 2024 and Salem Generating Station - Notice of Intent to Pursue Subsequent License Renewal LR-N24-0021, and Salem Generating Station, Units 1 and 2 - Guarantees of Payment of Deferred Premiums2024-03-20020 March 2024 and Salem Generating Station, Units 1 and 2 - Guarantees of Payment of Deferred Premiums ML24071A2132024-03-12012 March 2024 Senior Reactor and Reactor Operator Initial License Examinations LR-N24-0020, Generation Station and Salem Generating Station, Units 1 & 2 - Annual Property Insurance Status Report2024-03-0707 March 2024 Generation Station and Salem Generating Station, Units 1 & 2 - Annual Property Insurance Status Report LR-N24-0022, Spent Fuel Cask Registration2024-02-29029 February 2024 Spent Fuel Cask Registration IR 05000272/20230062024-02-28028 February 2024 Annual Assessment Letter for Salem Nuclear Generating Station, Units 1 and 2 (Reports 05000272/2023006 and 05000311/2023006 IR 05000272/20244012024-02-26026 February 2024 and Salem Nuclear Generating Station, Units 1 and 2 - Security Baseline Inspection Report 05000354/2024401, 05000272/2024401 and 05000311/2024401 (Cover Letter Only) IR 05000272/20230042024-02-0505 February 2024 Integrated Inspection Report 05000272/2023004 and 05000311/2023004 LR-N24-0009, In-Service Inspection Activities2024-02-0505 February 2024 In-Service Inspection Activities ML24009A1022024-01-26026 January 2024 – Exemption from Select Requirements of 10 CF Part 73 (EPID L-2023-LLE-0045 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) IR 05000272/20234012024-01-22022 January 2024 Material Control and Accounting Program Inspection Report 05000272/2023401 and 05000311/2023401 ML24004A1542024-01-0808 January 2024 Notification of Conduct of a Fire Protection Team Inspection LR-N23-0079, Special Report 23-02-00 Pursuant to the Requirements of Salem Unit 1 Technical Specification 3.3.3.7, Action 10, for the Unit 1 Main Steam Line Rad Monitor Inoperable for Greater than Seven Days2023-12-0707 December 2023 Special Report 23-02-00 Pursuant to the Requirements of Salem Unit 1 Technical Specification 3.3.3.7, Action 10, for the Unit 1 Main Steam Line Rad Monitor Inoperable for Greater than Seven Days ML23270C0072023-11-29029 November 2023 Notice of Proposed Amendment to Decommissioning Trust Agreement LR-N23-0077, Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2023 & 30 Day Report for Salem Unit 1 Upflow Conversion2023-11-29029 November 2023 Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2023 & 30 Day Report for Salem Unit 1 Upflow Conversion ML23324A3072023-11-17017 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML24250A0582023-11-14014 November 2023 PSEG to Marine Mammal Stranding Center, Salem Sea Turtle Stranding Response Services IR 05000272/20230032023-11-13013 November 2023 Integrated Inspection Report 05000272/2023003 and 05000311/2023003 LR-N23-0072, Core Operating Limits Report Cycle 302023-11-0101 November 2023 Core Operating Limits Report Cycle 30 IR 05000272/20230102023-10-12012 October 2023 Biennial Problem Identification and Resolution Inspection Report O5000272/2023010 and 05000311/2023010 IR 05000272/20234022023-10-12012 October 2023 and Salem Nuclear Generating Station, Units 1 and 2 - Security Baseline Inspection Report 05000354/2023402, 05000272/2023402 and 05000311/2023402 (Cover Letter Only) LR-N23-0045, and Peach Bottom Atomic Power Station, Units 2 and 3 - Notice of Proposed Amendment to Decommissioning Trust Agreement2023-09-0808 September 2023 and Peach Bottom Atomic Power Station, Units 2 and 3 - Notice of Proposed Amendment to Decommissioning Trust Agreement ML23249A2612023-09-0606 September 2023 License Amendment Request to Modify the Salem and Hope Creek Exclusion Area Boundary IR 05000272/20230052023-08-31031 August 2023 Updated Inspection Plan for Salem Nuclear Generating Station, Units 1 and 2 (Reports 05000272/2023005 and 05000311/2023005) ML23233A0762023-08-21021 August 2023 Requalification Program Inspection ML23192A8212023-08-14014 August 2023 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Issuance of Amendment Nos. 234, 347, and 329 Revise Technical Specifications to Delete Meteorological Tower Location IR 05000272/20230022023-08-0909 August 2023 Integrated Inspection Report 05000272/2023002 and 05000311/2023002 LR-N23-0055, Special Report 272/23-01-00, Pursuant to the Requirements of Technical Specification 3.3.3.1, Action 23, for the Vent Noble Gas Rad Monitor Inoperable for Greater than Seven Days2023-08-0303 August 2023 Special Report 272/23-01-00, Pursuant to the Requirements of Technical Specification 3.3.3.1, Action 23, for the Vent Noble Gas Rad Monitor Inoperable for Greater than Seven Days IR 05000354/20230022023-08-0303 August 2023 Integrated Inspection Report 05000354/2023002 and Independent Spent Fuel Storage Installation Inspection Report 07200048/2023001 LR-N23-0054, In-Service Inspection Activities2023-07-26026 July 2023 In-Service Inspection Activities 2024-09-25
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Robert Braun President and Chief Nuclear Officer PSEG Nuclear LLC -N09 P.O. Box 236 Hancocks Bridge, NJ 08038 September 15, 2015 SUBJECT: SALEM NUCLEAR GENERATING STATION, UNIT NO. 1 -LICENSE RENEWAL COMMITMENT IMPLEMENTATION TO RENEWED FACILITY OPERATING LICENSE CONDITION 2.C.21 (TAC NO. MF6126) Dear Mr. Braun: By letter dated March 4, 2015 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML 15069A110), PSEG Nuclear LLC (PSEG or the licensee) submitted a letter in accordance with the Renewed Facility Operating License (RFOL) Condition 2.C.21 for Salem Nuclear Generating Station, Unit No. 1 (Salem). The RFOL for Salem was issued on June 30, 2011 (ADAMS Accession No. ML 11166A135). RFOL Condition 2.C.21 states: PSEG Nuclear LLC shall take one core sample in the Unit 1 spent fuel pool west wall, by the end of 2013, and one core sample in the east wall where there have been indications of borated water ingress through the concrete, by the end of 2015. The core samples (east and west walls) will expose the rebar, which will be examined for signs of corrosion. Any sample showing signs of concrete degradation and/or rebar corrosion will be entered into the licensee's corrective action program for further evaluation. PSEG Nuclear LLC shall submit a report in accordance with 10 CFR 50.4 no later than three months after each sample is taken on the results, recommendations, and any additional planned actions. In its letter dated March 4, 2015, PSEG outlined the results of petrographic examination findings from the east wall concrete core bore, as well as findings from visual examinations of the reinforcement for corrosion. PSEG provided the results of the examination findings from the west wall concrete bore in a letter dated November 12, 2013 (ADAMS Accession No. ML 13317B684). The U.S. Nuclear Regulatory Commission (NRC) staff's evaluation of the condition of the west wall bored concrete and the exposed steel reinforcement was addressed previously by a letter dated May 8, 2014(ML14100A180). According to the March 4, 2015, letter, PSEG obtained a 5-inch (12.7 centimer (cm)) long by 4-inch (10.2 cm) diameter core bore from the Salem spent fuel pool (SFP) east wall in the vicinity of the construction joint. PSEG stated that the petrographic examination was visual and in accordance with American Society for Testing and Materials C856. The sample obtained demonstrated that the extracted concrete is in good condition and the cement paste was unaffected by chemical attacks, showing no signs of softening, degradation, or dissolution. The slightly yellow/orange discoloration that was observed within 0.039 inch (1-mm) of the R. Braun -2-construction joint was attributed by PSEG to carbonation of the floor slab surface during original construction. PSEG stated that petrographic examination did not identify any signs of degradation related to ingress of borated water through the concrete. PSEG concluded that the structural performance of the Salem fuel handling building has not been impacted due to leakage of SFP borated water. In addition to the core sample, PSEG excavated a small area of the east wall in the vicinity of the lateral construction joint to expose and assess the condition of a portion of the reinforcing steel. PSEG stated that the exposed reinforcement steel had no visible signs of corrosion. The licensee summarized the findings for concrete and rebar examination by stating, in part, that, "[t]he removal and examination of the core sample in the Unit 1 spent fuel pool east wall did not show any indications of concrete degradation due to borated water ingress through the concrete. Also, the exposed rebar did not show signs of aging-related corrosion." NRC staff reviewed the licensee's letter dated March 4, 2015, documenting its 2015 actions and results related to RFOL Condition 2.C.21. The NRC staff noted that the petrographic examinations of the concrete showed that it is in good condition with no signs of degradation related to chemical attacks due to borated water leakage. The staff also noted that the licensee's visual examination of the exposed reinforcing steel did not show signs of degradation due to corrosion. Based on its review of the licensee's examination of the concrete core bore sample and steel reinforcement on the Salem SFP east wall, the NRC staff finds that this examination provides reasonable assurance that the examined materials are in good condition. Further, there are no findings of significance that have a bearing on the aging management of concrete or reinforcing steel for further evaluation. Based on its review, the NRC staff concludes that the licensee has provided the required information and completed the actions required by RFOL Condition 2.C.21 for 2015. This completes the NRC's staff review of TAC No. MF6126.
R. Braun -3 -If you have any questions concerning this matter, please contact me at 301-415-1603 or Carleen.Parker@nrc.gov. Docket No. 50-272 cc: Distribution via Listserv Sincerely, II -*-*-1 . Cv.1L ) \ c./"' ____ _ Carleen J. Parkir, reject Manager Plant nch 1-2 Division of Oper 1ng Reactor Licensing Office of Nuclear Reactor Regulation R. Braun -3-If you have any questions concerning this matter, please contact me at 301-415-1603 or Carleen.Parker@nrc.gov. Docket No. 50-272 cc: Distribution via Listserv DISTRIBUTION: PUBLIC LPL 1-2 R/F RidsNrrDorlLpl1-2 Resource RidsNrrLALRonewicz Resource RidsNrrDlrRasb Resource KMorganButler, OEDO Sincerely, IRA/ Carleen J. Parker, Project Manager Plant Licensing Branch 1-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation RidsRgn1 MailCenter Resource RidsACRS_MailCTR Resource RidsRgn1 MailCenter Resource RidsNrrPMSalem Resource JLopez, NRR ADAMS A ccess1on N ML 15236A058 o.: *b d t d 8/06/2015 1y memo a e OFFICE DORL/LPLl-2/PM DORL/LPLl-2/LA DLR/RASB/BC DORL/LPLl-2/BC DORL/LPLl-2/PM NAME CParker LRonewicz BWittick* DBroaddus CParker DATE 8/24/2015 8/25/2015 8/06/2015 9/15/2015 9/15/2015 OFFICIAL RECORD COPY