ML18057A422: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 17: | Line 17: | ||
=Text= | =Text= | ||
{{#Wiki_filter:CONSUMERS POWER COMPANY Docket 50-255 Request for Change to the Technical Specifications License DPR-20 For the reasons hereinafter set forth, it is requested that the Technical Specifications contained in the Provisional Operating License DPR-20, Docket 50-255, issued to Consumers Power Company on October 16, 1972, for the Palisades Plant be changed as described in Section I below: I. Changes A. Change section 3 .11. la to read "With at least 160 of the 215 possible incore detectors and 2 incores per axial level per core quadrant." B. Change section 3.23.1, action 3, to read " *.. Readings shall be taken on a minimum of 10 individual detectors per quadrant (to include a total number of 160 detectors in a 10-hour period) within 4 hours ... " C. Change the last paragraph of the basis for section 3.23.1 to read | {{#Wiki_filter:CONSUMERS POWER COMPANY Docket 50-255 Request for Change to the Technical Specifications License DPR-20 For the reasons hereinafter set forth, it is requested that the Technical Specifications contained in the Provisional Operating License DPR-20, Docket 50-255, issued to Consumers Power Company on October 16, 1972, for the Palisades Plant be changed as described in Section I below: | ||
I. Changes A. Change section 3 .11. la to read "With at least 160 of the 215 possible incore detectors and 2 incores per axial level per core quadrant." | |||
"(6) FSAR Section 7.6.2.4". | B. Change section 3.23.1, action 3, to read " *.. Readings shall be taken on a minimum of 10 individual detectors per quadrant (to include a total number of 160 detectors in a 10-hour period) within 4 hours ... " | ||
C. Change the last paragraph of the basis for section 3.23.1 to read factors 5 given in Table 3.23-3, an engineering uncertainty factor of | |||
Measurement( ) Uncertainty c | " ... take~ tnto account the local LHGR measurement uncertainty 1.03, and a thermal power measurement uncertainty factor of 1.02." | ||
900024 r 050002515 PNU OC0890-0399-NL02 | Also add new references (5) and (6) to the list of references to read I | ||
II. Discussion PIDAL is an incore analysis routine developed by Consumers Power Company and is capable of determining the power distribution, peaking factors and LHGR, on a full core basis. This is in contrast to the current INCA model which must assume one-eighth core radial symmetry within the reactor core. There are two major driving forces for the conversion from INCA to PIDAL. First, there is an increasing need to deviate from one-eighth core symmetric fuel loading patterns due to limitations on core design caused by reactor vessel fluence concerns. | "(5) FSAR Section 3.3.2.5". | ||
It has become clear that quarter core loading patterns will be required in order to meet goals established for vessel fluence while maintaining fuel cycle length. Secondly, it is expected PIDAL will allow full detection and measurement capabilities should non-symmetric power anomalies occur; ie, misaligned rods. INCA, being a one-eighth core model cannot accurately measure the core power distribution when localized asymmetric power distributions occur. In addition, the uncertainty evaluation for the INCA model was conserXi\.tive in some areas. Of immediate is the of a 0.5% F margin gain by switching to PIDAL. This translates-'tx>'-*a roughl§ 1. 5% reactor gain at hot full power. During Cycle 8 operation, the F margin was exhausted and this may""reeur in the future. r OC0890-0399-NL02 | "(6) FSAR Section 7.6.2.4". / | ||
D. Add new Table 3.23-3 to read as follows: | |||
"TABLE 3.23-3 POWER DISTRIBUTION MEASUREMENT UNCERTAINTY FACTORS LHR/Peaking Factor Measurement ) Measurementb) Measurement( ) I Parameter Uncertainty a Uncertainty Uncertainty c I I | |||
I LHR 0.0623 0.0664 0.0795 I I | |||
FA 0.0401 0.0490 0.0695 I r | |||
Ftih I 0.0455 0.0526 0.-0722 I r | |||
I (a) Measurement uncertainty for reload cores using all f~~~h I incore detectors. I (b) Measurement uncertainty for reload cores using a mixture I of fre§h and once-burned incore detectors. I 9008310019 900024 r PDR ADOCK 050002515 p PNU OC0890-0399-NL02 | |||
(c) Measurement uncertainty when quadrant power tilt, as determined I using i~g~re measurements and an incore analysis computer I program , exceeds 2.8% but is less than or equal to 5%." I E. Add the following paragraph and reference to the basis for section 3.23-2 to read: | |||
"To ensure that the design margin of safety is maintained, the determination of the radial peaking factors(fykes into account the appropriate measurement uncertainty factors given in Table 3.23-3. | |||
References (1) FSAR Section 3.3.2.5" F. Change the last two sentences of the basis for section 3.23.3 to read "Quadrant power tilt calibration factors are determine~ ysing incore measurements and an incore analysis computer program 2 ." and add new reference (2) to the list of references to read "(2) FSAR Section 7.6.2.4". | |||
II. Discussion PIDAL is an incore analysis routine developed by Consumers Power Company and is capable of determining the power distribution, peaking factors and LHGR, on a full core basis. This is in contrast to the current INCA model which must assume one-eighth core radial symmetry within the reactor core. There are two major driving forces for the conversion from INCA to PIDAL. | |||
First, there is an increasing need to deviate from one-eighth core symmetric fuel loading patterns due to limitations on core design caused by reactor vessel fluence concerns. It has become clear that quarter core loading patterns will be required in order to meet goals established for vessel fluence while maintaining fuel cycle length. | |||
Secondly, it is expected PIDAL will allow full detection and measurement capabilities should non-symmetric power anomalies occur; ie, misaligned rods. INCA, being a one-eighth core model cannot accurately measure the core power distribution when localized asymmetric power distributions occur. | |||
In addition, the uncertainty evaluation for the INCA model was overly-conserXi\.tive in some areas. Of immediate inter~st is the be1.'1ef~t of a 0.5% F margin gain by switching to PIDAL. This translates-'tx>'-*a roughl§ 1. 5% reactor pow~fi gain at hot full power. During i"?i.t~al Cycle 8 operation, the F margin was exhausted and this may""reeur in the future. r OC0890-0399-NL02 \ | |||
The PIDAL program varies significantly from that of INCA. Most notably it monitors the full core on an assembly by assembly basis, rather than by averaging symmetric assemblies into an octant representation. | The PIDAL program varies significantly from that of INCA. Most notably it monitors the full core on an assembly by assembly basis, rather than by averaging symmetric assemblies into an octant representation. | ||
PIDAL uses a modern method of coupling uninstrumented assemblies with instrumented neighbors in order to determine the nodal power tion. PIDAL incorporates a mathematically rigorous method for determining incore quadrant power tilt which is believed to be more accurate than the INCA fitting method. PIDAL also has the capability of determining quadrant power tilt using an integral quadrant power method similar to INCA's. The documentation effort for the PIDAL program and uncertainty analysis has been completed, resulting in a computer program which is better documented and easier to maintain than the INCA program. The PIDAL software was designed using standard state-of-the-art techniques which will allow maximum flexibility for future use as an on-line, real-time monitoring system. Attachment 3 provides the uncertainty analysis associated with PIDAL for measurements with radial power tilts present, and Attachment 4 provides proposed FSAR changes to reflect the new PIDAL program. Changes A and B revise affected Technical Specification sections to allow use of the PIDAL program. The PIDAL modeling will maintain acceptable uncertainties with up to 55 of 215 incore detectors inoperable. | PIDAL uses a modern method of coupling uninstrumented assemblies with instrumented neighbors in order to determine the nodal power distribu-tion. PIDAL incorporates a mathematically rigorous method for determining incore quadrant power tilt which is believed to be more accurate than the INCA fitting method. PIDAL also has the capability of determining quadrant power tilt using an integral quadrant power method similar to INCA's. | ||
Changes C, E and F revise affected basis sections to reflect use of the PIDAL program and to include FSAR references which describe the program. Change D incorporates the PIDAL uncertainty factor into the Technical Specifications. | The documentation effort for the PIDAL program and uncertainty analysis has been completed, resulting in a computer program which is better documented and easier to maintain than the INCA program. The PIDAL software was designed using standard state-of-the-art techniques which will allow maximum flexibility for future use as an on-line, real-time monitoring system. Attachment 3 provides the uncertainty analysis associated with PIDAL for measurements with radial power tilts present, and Attachment 4 provides proposed FSAR changes to reflect the new PIDAL program. | ||
Analysis of No Significant Hazards Consideration The incore analysis software, previously INCA and now PIDAL, is primarily a monitoring tool and is not considered as a possible initiator for an accident. | Changes A and B revise affected Technical Specification sections to allow use of the PIDAL program. The PIDAL modeling will maintain acceptable uncertainties with up to 55 of 215 incore detectors inoperable. | ||
As a core monitoring tool, it is used to confirm inputs for the accident analysis. | Changes C, E and F revise affected basis sections to reflect use of the PIDAL program and to include FSAR references which describe the program. | ||
It is used to verify that reactor operation is bounded by the assumptions made in performing the safety and accident analysis. | Change D incorporates the PIDAL uncertainty factor into the Technical Specifications. | ||
The new PIDAL model has been benchmarked against and shown to agree well with the INCA model. It is not expected that the core power distribution parameters measured by PIDAL and used as inputs to the accident analysis will be significantly different from analogous INCA values. The program and inputs to the program will receive the same technical reviews and Administrative controls as did the INCA program. The PIDAL program change will result in an analytical representation of core parameters which is at least as accurate as the INCA program. Therefore, there will be no increase in the probability or consequences of a previously evaluated accident nor will it create a new or different kind of accident. | Analysis of No Significant Hazards Consideration The incore analysis software, previously INCA and now PIDAL, is primarily a monitoring tool and is not considered as a possible initiator for an accident. As a core monitoring tool, it is used to confirm inputs for the accident analysis. It is used to verify that reactor operation is bounded by the assumptions made in performing the safety and accident analysis. The new PIDAL model has been benchmarked against and shown to agree well with the INCA model. | ||
OC0890-0399-NL02 | It is not expected that the core power distribution parameters measured by PIDAL and used as inputs to the accident analysis will be significantly different from analogous INCA values. The program and inputs to the program will receive the same technical reviews and Administrative controls as did the INCA program. The PIDAL program change will result in an analytical representation of core parameters which is at least as accurate as the INCA program. Therefore, there will be no increase in the probability or consequences of a previously evaluated accident nor will it create a new or different kind of accident. | ||
*' tih .... The linear heat generation rate and F peaking factor measurement uncertainties associated with the PIDAL model are lower than those assumed for INCA. However, in conformance with accepted practices, the PIDAL uncertainty analysis determined 95/95 probability/confidence one-sided tolerance limits for the power distribution measurement Therefore, the margin of safety as related to measuring the reactor power distribution will not be reduced by switching to the PIDAL program. III. Conclusion The Palisades Plant Review Committee has reviewed this Technical Specification Change Request and has determined that this change does not involve an unreviewed safety question and, therefore, involves no significant hazards consideration. | OC0890-0399-NL02 | ||
This change has been reviewed by the Nuclear Safety Services Department. | |||
A copy of this Technical tion Change Request has been sent to the State of Michigan official designated to receive such Amendments to the Operating License. CONSUMERS POWER COMPANY To the | *' | ||
tih .... | |||
The linear heat generation rate and F peaking factor measurement uncertainties associated with the PIDAL model are lower than those assumed for INCA. However, in conformance with accepted practices, the PIDAL uncertainty analysis determined 95/95 probability/confidence one-sided tolerance limits for the power distribution measurement uncert~inties. Therefore, the margin of safety as related to measuring the reactor power distribution will not be reduced by switching to the PIDAL program. | |||
III. Conclusion The Palisades Plant Review Committee has reviewed this Technical Specification Change Request and has determined that this change does not involve an unreviewed safety question and, therefore, involves no significant hazards consideration. This change has been reviewed by the Nuclear Safety Services Department. A copy of this Technical Specifica-tion Change Request has been sent to the State of Michigan official designated to receive such Amendments to the Operating License. | |||
CONSUMERS POWER COMPANY To the information and belief, the contents of this Technic Request are truthful and complete. | |||
Sworn and subscribed to before me this 24th day of August, 1990. | Sworn and subscribed to before me this 24th day of August, 1990. | ||
~)tli~ | |||
Elaine E Buehrer, Notary Public Jackson County, Michigan My commission expires October 11, 1993 OC0890-0399-NL02}} | Elaine E Buehrer, Notary Public Jackson County, Michigan My commission expires October 11, 1993 OC0890-0399-NL02}} |
Revision as of 18:39, 21 October 2019
ML18057A422 | |
Person / Time | |
---|---|
Site: | Palisades |
Issue date: | 08/24/1990 |
From: | Heins G CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
To: | |
Shared Package | |
ML18057A421 | List: |
References | |
NUDOCS 9008310019 | |
Download: ML18057A422 (4) | |
Text
CONSUMERS POWER COMPANY Docket 50-255 Request for Change to the Technical Specifications License DPR-20 For the reasons hereinafter set forth, it is requested that the Technical Specifications contained in the Provisional Operating License DPR-20, Docket 50-255, issued to Consumers Power Company on October 16, 1972, for the Palisades Plant be changed as described in Section I below:
I. Changes A. Change section 3 .11. la to read "With at least 160 of the 215 possible incore detectors and 2 incores per axial level per core quadrant."
B. Change section 3.23.1, action 3, to read " *.. Readings shall be taken on a minimum of 10 individual detectors per quadrant (to include a total number of 160 detectors in a 10-hour period) within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> ... "
C. Change the last paragraph of the basis for section 3.23.1 to read factors 5 given in Table 3.23-3, an engineering uncertainty factor of
" ... take~ tnto account the local LHGR measurement uncertainty 1.03, and a thermal power measurement uncertainty factor of 1.02."
Also add new references (5) and (6) to the list of references to read I
"(5) FSAR Section 3.3.2.5".
"(6) FSAR Section 7.6.2.4". /
D. Add new Table 3.23-3 to read as follows:
"TABLE 3.23-3 POWER DISTRIBUTION MEASUREMENT UNCERTAINTY FACTORS LHR/Peaking Factor Measurement ) Measurementb) Measurement( ) I Parameter Uncertainty a Uncertainty Uncertainty c I I
I LHR 0.0623 0.0664 0.0795 I I
FA 0.0401 0.0490 0.0695 I r
Ftih I 0.0455 0.0526 0.-0722 I r
I (a) Measurement uncertainty for reload cores using all f~~~h I incore detectors. I (b) Measurement uncertainty for reload cores using a mixture I of fre§h and once-burned incore detectors. I 9008310019 900024 r PDR ADOCK 050002515 p PNU OC0890-0399-NL02
(c) Measurement uncertainty when quadrant power tilt, as determined I using i~g~re measurements and an incore analysis computer I program , exceeds 2.8% but is less than or equal to 5%." I E. Add the following paragraph and reference to the basis for section 3.23-2 to read:
"To ensure that the design margin of safety is maintained, the determination of the radial peaking factors(fykes into account the appropriate measurement uncertainty factors given in Table 3.23-3.
References (1) FSAR Section 3.3.2.5" F. Change the last two sentences of the basis for section 3.23.3 to read "Quadrant power tilt calibration factors are determine~ ysing incore measurements and an incore analysis computer program 2 ." and add new reference (2) to the list of references to read "(2) FSAR Section 7.6.2.4".
II. Discussion PIDAL is an incore analysis routine developed by Consumers Power Company and is capable of determining the power distribution, peaking factors and LHGR, on a full core basis. This is in contrast to the current INCA model which must assume one-eighth core radial symmetry within the reactor core. There are two major driving forces for the conversion from INCA to PIDAL.
First, there is an increasing need to deviate from one-eighth core symmetric fuel loading patterns due to limitations on core design caused by reactor vessel fluence concerns. It has become clear that quarter core loading patterns will be required in order to meet goals established for vessel fluence while maintaining fuel cycle length.
Secondly, it is expected PIDAL will allow full detection and measurement capabilities should non-symmetric power anomalies occur; ie, misaligned rods. INCA, being a one-eighth core model cannot accurately measure the core power distribution when localized asymmetric power distributions occur.
In addition, the uncertainty evaluation for the INCA model was overly-conserXi\.tive in some areas. Of immediate inter~st is the be1.'1ef~t of a 0.5% F margin gain by switching to PIDAL. This translates-'tx>'-*a roughl§ 1. 5% reactor pow~fi gain at hot full power. During i"?i.t~al Cycle 8 operation, the F margin was exhausted and this may""reeur in the future. r OC0890-0399-NL02 \
The PIDAL program varies significantly from that of INCA. Most notably it monitors the full core on an assembly by assembly basis, rather than by averaging symmetric assemblies into an octant representation.
PIDAL uses a modern method of coupling uninstrumented assemblies with instrumented neighbors in order to determine the nodal power distribu-tion. PIDAL incorporates a mathematically rigorous method for determining incore quadrant power tilt which is believed to be more accurate than the INCA fitting method. PIDAL also has the capability of determining quadrant power tilt using an integral quadrant power method similar to INCA's.
The documentation effort for the PIDAL program and uncertainty analysis has been completed, resulting in a computer program which is better documented and easier to maintain than the INCA program. The PIDAL software was designed using standard state-of-the-art techniques which will allow maximum flexibility for future use as an on-line, real-time monitoring system. Attachment 3 provides the uncertainty analysis associated with PIDAL for measurements with radial power tilts present, and Attachment 4 provides proposed FSAR changes to reflect the new PIDAL program.
Changes A and B revise affected Technical Specification sections to allow use of the PIDAL program. The PIDAL modeling will maintain acceptable uncertainties with up to 55 of 215 incore detectors inoperable.
Changes C, E and F revise affected basis sections to reflect use of the PIDAL program and to include FSAR references which describe the program.
Change D incorporates the PIDAL uncertainty factor into the Technical Specifications.
Analysis of No Significant Hazards Consideration The incore analysis software, previously INCA and now PIDAL, is primarily a monitoring tool and is not considered as a possible initiator for an accident. As a core monitoring tool, it is used to confirm inputs for the accident analysis. It is used to verify that reactor operation is bounded by the assumptions made in performing the safety and accident analysis. The new PIDAL model has been benchmarked against and shown to agree well with the INCA model.
It is not expected that the core power distribution parameters measured by PIDAL and used as inputs to the accident analysis will be significantly different from analogous INCA values. The program and inputs to the program will receive the same technical reviews and Administrative controls as did the INCA program. The PIDAL program change will result in an analytical representation of core parameters which is at least as accurate as the INCA program. Therefore, there will be no increase in the probability or consequences of a previously evaluated accident nor will it create a new or different kind of accident.
OC0890-0399-NL02
- '
tih ....
The linear heat generation rate and F peaking factor measurement uncertainties associated with the PIDAL model are lower than those assumed for INCA. However, in conformance with accepted practices, the PIDAL uncertainty analysis determined 95/95 probability/confidence one-sided tolerance limits for the power distribution measurement uncert~inties. Therefore, the margin of safety as related to measuring the reactor power distribution will not be reduced by switching to the PIDAL program.
III. Conclusion The Palisades Plant Review Committee has reviewed this Technical Specification Change Request and has determined that this change does not involve an unreviewed safety question and, therefore, involves no significant hazards consideration. This change has been reviewed by the Nuclear Safety Services Department. A copy of this Technical Specifica-tion Change Request has been sent to the State of Michigan official designated to receive such Amendments to the Operating License.
CONSUMERS POWER COMPANY To the information and belief, the contents of this Technic Request are truthful and complete.
Sworn and subscribed to before me this 24th day of August, 1990.
~)tli~
Elaine E Buehrer, Notary Public Jackson County, Michigan My commission expires October 11, 1993 OC0890-0399-NL02