!f!ons~m~m Power POWERING MICHIGAN-S PROGRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 March 26, 1997 U S Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT TECHNICAL SPECIFICATION CHANGE REQUEST - CONTAINMENT SYSTEM Thomas C. Bordine Manager, Licensing A request for a change to the Palisades Technical Specifications {TS) which revises the Containment System requirements is enclosed. This change is desired to allow entry into an air lock to perform repairs on an inoperable air lock door and thereby avoid the potential for an unnecessary plant shutdown.
That change involves addition of footnotes to TS 3.6.l and TS 4.5.2, similar to Note 1 in Standard Technical Specifications {STS) LCO 3.6.2.
During the process of preparing the TS change request {TSCR), it was determined that it was appropriate to revise TS Sections 3.6 and 4.5 in general.
The items needing revision are:
- 1)
LCO 3.6.2, Containment Pressure, and its basis contain less restrictive limits than are currently assumed as initial conditions in the safety analyses;
- 2)
- 3)
- 4)
- 5)
- 6)
LCO 3.6.2 includes no action statement to address a plant condition where containment pressure exceeds the TS limit.
Existing TS contain no LCO for containment temperature; LCOs 3.6.3 and 3.6.5 and their bases are inconsistent; The terminology in TS Sections 3.6 and 4.5 is inconsistent, and Existing TS contain component lists which may be removed in accordance with the guidance of Generic Letter 91-08.
9704010562 970326 PDR ADOCK 05000255 P
PDR A CMS' ENERGY COMPANY I If 1111 jllll ~II l[llll fllll f 1111 Jllll lllll Jllll Jiii If II
\\\\\\
~U\\
The enclosed TSCR proposes many changes to these two TS sections.
Most of the
' chariges are editorial and do not change any TS limits. Four technical changes make TS requirements more restrictive:
- 1)
Reducing the TS LCO 3.6.2 limit for containment pressure,
- 2)
Adding an action statement for LCO 3.6.2,
- 3)
Adding a new LCO 3.6.3 for containment temperature, and
- 4)
Revising the containment purge valve LCO 3.6.5, to agree with the wording in its basis, to be applicable above 210°F rather than above 525°F.
Three other technical changes make TS requirements less restrictive, but are features of STS:
- 1)
The addition of an allowance in TS 3.6.1 and TS 4.5.2 to enter an air lock through a locked door to perform maintenance, and
- 2)
The generalization of the TS 3.6.1 allowance to open specific isolation valves under administrative control so that it applies to all containment penetration flow paths.
(This generalization also is suggested by Generic Letter 91-08.)
- 3)
Revising Containment Pressure LCO 3.6.2 so that it is no longer applicable during Cold Shutdown.
In addition, the TS table of containment isolation valves and the specific component identifiers used in TS section 3.6 have been deleted in accordance with the guidance of GL 91-08.
The proposed editorial changes are intended to enhance the clarity of these TS sections by grouping the LCOs together, by deleting unnecessary wording, and by using consistent terminology throughout.
It is requested that this change request receive expedited review to decrease the probability of a required plant shutdown due to easily repaired air lock door leakage, and that this change become effective upon approval.
SUMMARY
OF COMMITMENTS This letter establishes no new commitments and makes no revisions to existing commitments.
~L~
Thomas C. Berdine Li cens i-ng Manager CC Administrator, Region III, USNRC Project Manager, NRR, USNRC NRC Resident Inspector - Palisades Enclosure
CONSUMERS POWER COMPANY TECHNICAL SPECIFICATION CHANGE REQUEST CONTAINMENT SYSTEM To the best of my knowledge, the content of this Technical Specification change request, which revises the Containment System LCOs and Surveillance Requirements, is truthful and complete.
~~<(~
~--""""""T""'ho
..... m_a __ s-~C..... ~=o"""rd"':""it=n""'"e-=----
Manager, Licensing Sworn and subscribed to before me this CJ~ ii day of ~~ 1997.
Alora M. Davis, Notary Public Berrien County, Michigan (Acting in Van Buren County, Michigan)
My commission expires August 26, 1999