Rev to 940222 I&C TS Change Request to License DPR-20,adding Surveillance Item 10 to Table 4.2.1 Which Require Verifying SIT Level & Pressure Each Shift & Adding Three Paragraphs to Basis for Proposed Section 3.17
ML18059A885
Person / Time
Site: Palisades Entergy icon.png
Issue date: 03/11/1994
From: Rogers D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18059A886 List:
References
NUDOCS 9403170116
Download: ML18059A885 (1)


Text

consumers P1t1wer David W. Rogers Plant Safety and Licensing Director POWERINli MICHlliAN"S PROliRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 March 11, 1994 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - TECHNICAL SPECIFICATIONS CHANGE REQUEST - INSTRUMENTATION AND CONTROL - REVISED PAGES.

The attachment to this letter contains revised pages for our revised Instrument and Control (l&C) Technical Specifications (TS) change request which was submitted on February 22, 1994.

1) The first revision adds surveillance item 10 to Table 4.2.1 which requires verifying Safety Injection Tank (SIT) Level and Pressure each shift. This same surveillance requirement currently appears as item 13a of Table 4.1.2 in the Palisades TS. It was included in our November 15, 1991 l&C TS change request, but was inadvertently omitted from the February 22, 1994 revision.

Proposed pages 4-6 through 4-15 are included in the attachment to provide correct page numbering. These pages replace pages 4-6 through 4-16 of the February 22, 1994 submittal.

2) The second revision adds three paragraphs to the basis for proposed section 3.17, under the heading "Minimum Operable Channels". This addition of text was suggested by the NRC reviewer, Mr. Ahmed, as clarification of the proposed l&C section.

The changes proposed in this letter do not alter the conclusions of the No Significant Hazards Analysis contained in our November 15, 1991 letter on this subject. A copy of this letter has been sent to the State of Michigan.

CC Administrator, Region Ill, USNRC Resident Inspector, Palisades Attachment

.16 OJ1_0_7 _

,-** 9403170116 940311 PDR ADOCK 05000255 p PDR A CM5 ENERGY COMPANY