{{Adams
| number = ML110600706
| issue date = 02/25/2011
| title = St. Lucie, Unit 1 - Response to NRC Request for Additional Information (RAI) Regarding Extended Power Uprate License Amendment Request
| author name = Anderson R L
| author affiliation = Florida Power & Light Co
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR
| docket = 05000335
| license number = DPR-067
| contact person =
| case reference number = L-2011-076
| document type = Letter
| page count = 24
| project =
| stage = Response to RAI
}}
 
=Text=
{{#Wiki_filter:Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 February 25, 2011 FlPL This letter forwards proprietary information in accordance with 10 CFR 2.390. The balance of this letter may be considered non-proprietary upon removal of Attachment 1.L-2011-076 10 CFR 50.90 U.S, Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Re: St. Lucie Plant Unit I Docket No. 50-335 Renewed Facility Operating License No. DPR-67 Response to NRC Request for Additional Information (RAI) Regarding Extended Power Uprate License Amendment Request  
 
==References:==
 
(1) R. L. Anderson (FPL) to U.S. Nuclear Regulatory Commission (L-2010-259),"License Amendment Request for Extended Power Uprate, November 22, 2010, Accession No. ML103560419.
(2) Email from T. Orf (NRC) to C. Wasik (FPL), "Requested St. Lucie Unit I EPU Information," January 13, 2011, Accession No. ML 110130412.
(3) Westinghouse Report, CE-NPSD-683-A Task-i 174, Revision 06, "Development of a RCS Pressure and Temperature Limits Report for the Removal of P-T Limits and LTOP requirements from the Technical Specifications," April 2001, Accession No. MLO0113503871.
By letter L-2010-259 dated November 22, 2010 [Reference 1], Florida Power & Light Company (FPL) requested to amend Renewed Facility Operating License No. DPR-67 and revise the St. Lucie Unit 1 Technical Specifications (TS). The proposed amendment will increase the unit's licensed core thermal power level from 2700 megawatts thermal (MWt) to 3020 MWt and revise the Renewed Facility Operating License and TS to support operation at this increased core thermal power level. This represents an approximate increase of 11.85% and is therefore considered an extended power uprate (EPU).By email from the NRC Project Manager dated January 13, 2011 [Reference 2], additional information regarding the analysis supporting proposed changes to the reactor coolant system pressure-temperature (P-T) limits was requested by the NRC staff in the Vessels and Internals Integrity Branch (CVIB) to support their review of the EPU LAR.A-oc5I an FPL Group company L-2011-076 Page 2 of 3 The request for additional information (RAI) identified that an exemption request related to the use of methodology contained within the Reference 3 topical report is required.The RAI also requested a tabulation of stress intensity factors (K values) used to generate the P-T limits. The tabulation of stress intensity factors, along with related curves, is provided in Attachment 1 to this letter. The exemption request will be provided under separate cover.The Reference 2 RAI email notes that FPL will provide, with the exemption request, responses to the supplemental information questions listed in the Reference 3 topical report and/or identify which questions do not apply; however, in a telephone conference between FPL and the NRC on January 19, 2011, it was agreed that the response to the supplemental information questions would not be included with the exemption request, but would be submitted along with the tabulation of stress intensity values. Attachment 2 to this letter provides responses to the supplemental information questions.
Attachment 3 contains the application for withholding proprietary information contained in Attachment 1 from public disclosure.
As Attachment 1 contains information proprietary to Westinghouse Electric Company, LLC (Westinghouse), it is supported by an affidavit signed by Westinghouse, the owner of the information.
The affidavit sets forth the basis for which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4)of §2.3 90 of the Commission's' regulations.
Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR 2.390 of the Commission's regulations.
Correspondence with respect to the copyright or proprietary aspects of Attachment 1 of this letter or the supporting Westinghouse affidavit should reference CAW-1 1-3065 and should be addressed to J. A. Gresham, Manager, Regulatory Compliance and Plant Licensing, Westinghouse Electric Company LLC, Suite 428, 1000 Westinghouse Drive, Cranberry Township, PA 16066.Attachment 4 provides a public version of the Attachment 1 tabulation of stress intensity factors and related curves.In accordance with 10 CFR 50.9 1(b)(1), a copy of this letter is being forwarded to the Designated State of Florida official.This submittal does not alter the significant hazards consideration or environmental assessment previously submitted by FPL letter L-2010-259
[Reference 1].This submittal contains no new commitments and no revisions to existing commitments.
Should you have any questions regarding this submittal, please contact Mr. Christopher Wasik, St. Lucie Extended Power Uprate LAR Project Manager, at 772-429-7138.
L-2011-076 Page 3 of 3 1 declare under penalty of perjury that the foregoing is true and correct to the best of my knowledge.
Executed on ,e- ,,, 2 Very truly yours, Richard L. Anderson Site Vice President St. Lucie Plant Attachments cc: Administrator, Region II, USNRC Project Manager, St. Lucie Nuclear Plant, USNRC Senior Resident Inspector, St. Lucie Nuclear Plant, USNRC Mr. William Passetti, Florida Department of Health L-2011-076 Attachment 2 Page 1 of 5 Attachment 2 Responses to Supplemental Information Requirements L-2011-076 Attachment 2 Page 2 of 5 Discussion Section 5.0 of the NRC Safety Evaluation (SE) for CE-NPSD-683-A contains twenty-six items of information to be included in pressure-temperature limits report (PTLR) License Amendment Requests to satisfy the criteria of the table in Attachment 1 to Generic Letter (GL) 96-03. GL 96-03, "Relocation of the Pressure Temperature Limit Curves and Low Temperature Overpressure Protection System Limits," provides guidance on relocating the pressure-temperature (P-T) limits and certain low temperature overpressure protection (LTO P) controls from the Technical Specifications to a PTLR. The table in Attachment 1 to GL 96-03 contains information requirements related to the methodology for generating P-T limits and LTOP setpoints.
Florida Power and Light (FPL), in their St. Lucie Unit I (PSL1) Extended Power Uprate (EPU)License Amendment Request (LAR), requests approval of changes to the P-T limits based on CE-NPSD-683-A methodology.
The technical basis for the new P-T limits and the basis and methodology for the LTOP evaluation that is supported by the proposed P-T limits is described in the Westinghouse document WCAP-17197-NP.
WCAP-17197-NP was prepared by Westinghouse and provided to FPL to support the proposed PS Li P-T limits described in the EPU LAR.Although FPL is not requesting that the PS LI P-T limits be relocated to a PTLR, since FPL is using the P-T limits methodology from CE-NPSD-683-A for St. Lucie Unit 1, each of the twenty-six information items from Section 5.0 of the CE-NPSD-683-A safety evaluation (SE) is stated below along with an assessment of the applicable proposed change to the St. Lucie Unit 1 P-T limits.Information Items from Section 5.0 of the CE-NPSD-683-A SE Information needed to satisfy Criterion 1 of the Table in Attachment I to GL 96-03, which deals with the topic of neutron fluence calculational methods -Licensees will need to: (1) Describe the methodology used to calculate the neutron fluence values for the reactor vessel materials, including a description of whether or not the methodology is consistent with the guidance of Draft Regulatory Guide DG-1 053, a description of the computer codes used to calculate the neutron fluence values, and a description of how the computer codes for calculating the neutron fluence values were benchmarked; and (2) Provide the values of neutron fluence used for the adjusted reference temperature (RT1OT) calculations, including the values of neutron fluence for the ihner surface (ID), 1/4T and 3/4T locations of the RPV.Assessment:
Items 1 and 2 do not provide information necessary to support the P-T limit methodology
-this information supports fluence determination.
No response required -for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP does not describe the methodology to calculate neutron fluence.Information needed to satisfy Criterion 2 of the Table in Attachment 7 to GL 96-03, which deals with the topic of reactor vessel material surveillance program designs and withdrawal schedules
-Licensees will need to:
L-2011-076 Attachment 2 Page 3 of 5 (3) Either provide the surveillance capsule withdrawal schedule in the proposed PTLR for the amendment or reference in the PTLR by title and number the documents in which the withdrawal schedule is located; and (4) Reference the surveillance capsule reports by title and number if the RTNDr values are calculated using RPV surveillance capsule data.Assessment:
Items 3 and 4 do not provide information necessary to support the P-T limit methodology
-this information supports the surveillance capsule schedule and report information.
No response required for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP does not describe the surveillance capsule withdrawal schedule or reports.Information needed to satisfy Criterion 3 of the Table in Attachment I to GL 96-03, which deals with the topic of describing the methodologies that will be used to establish the LTOP system limits -Licensees will need to: (5) Provide a description of the analytical method used in the energy addition transient analysis;(6) Provide a description of the analytical method used in the mass addition transient analysis, if different from that in Section 3.3.5 of the topical report;(7) Provide a description of the method for selection of relief valve setpoints; (8) Provide a justification for use of subcooled water conditions or a steam volume in the pressurizer; (9) Provide a justification for a less conservative method for determination of decay heat contribution if the method used is less conservative than the "most conservative method" described in the topical report;(10) Provide justification for operator action time used in transient mitigation or termination; (11) Provide correlations used for developing PORV discharge characteristics; (12) Provide spring relief valve discharge characteristics if different from those described in the topical report or if the peak transient pressure is above the set pressure of the valve plus 10 percent;(13) Provide a description of how the reactor coolant temperature instrumentation uncertainty was accounted for;(14) Provide a justification for the mass and energy addition transient mitigation which credit presence of nitrogen in the pressurizer; and (15) Identify and explain any other deviation from the methodology included in Section 3.0 of the topical report.Assessment:
Items 5 through 15 do not provide information necessary to support the P-T limit methodology
-this information supports LTOP Evaluation methods. No response required for a submittal that is not requesting approval of a PTLR.WCAP-1 7197-NP describes LTOP transient methods and assumptions in Sections 3.2 and 3.3.Information needed to satisfy Criterion 4 of the Table in Attachment I to GL 96-03, which deals with the topic of describing the methodologies that will be used to calculate the adjusted reference temperature values for the RPV materials
-Licensees will need to: (16) Identify the limiting materials and corresponding RTNDT values for both the quarter thickness (1/4T) and three-quarter-thickness (3/4T) locations of the RPV shell; and (17) For pressurized-water-reactor (PWR) design facilities, identify the limiting RTNDT value for RPV as calculated in accordance with the methods and criteria of 10 CFR 50.61.
L-2011-076 Attachment 2 Page 4 of 5 Assessment:
Items 16 and 17 do not provide information necessary to support the P-T limit methodology
-this information supports material property information.
No response required, for a submittal that is not requesting approval of a PTLR.WCAP-1 7197-NP describes the adjusted reference temperature in Section 2.1.Information needed to satisfy Criterion 5 of the Table in Attachment I to GL 96-03, which deals with the topic of describing the methodologies used to generate plant specific P-T limit curves -Licensees will need to: (18) Ensure that the ferritic RPV materials that have accumulated neutron fluences in excess of 1.0x1017 n/cm 2 (E > 1 MeV) will be assessed according to Section 4.0 of the CE Topical Report CE NPSD-683, Revision 6, regardless of whether the materials are located within the region immediately surrounding the active core;Assessment:
This item is not related to the C-E NPSD-683 P-T methodology.
No response required, for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP describes the material fluence projections in Section 2.1.(19) Identify which method (i.e., Kic or KIA) will be used to calculate the reference intensity factor (KIR) values for the RPV as a function of temperature; Assessment:
ASME Code has since been updated to use Kic criteria and, hence, was used in generating the St. Lucie Unit 1 P-T limits.(20) (Applicable only if Code Case N-640 and Kc are used as the basis for calculating the KIR values) submit an exemption request [pursuant to alternative program provisions of 10 CFR 50.60(b)]
to use the methods of Code Case N-640 and apply them to the P-T limit calculations.
Note that the staff will approve an exemption request to use Code Case N-640 and K 1 c as the bases for generating the P-T limit curves only if a licensee indicates that it will limit the maximum pressure in the vessel to 100 percent of the pressure satisfying Paragraph G-2215 of the 1996 Edition of Appendix G to the Code for establishing LTOP limit setpoints.
This condition is consistent with Note (2) on page 5-6 of CE NPSD-683, Revision 6;Assessment:
The 2004 Edition of the American Society of Mechanical Engineers (ASME) Code codified in the Code of Federal Regulations has incorporated the use of Kc criteria.
No response required.(21) (Applicable only if the CE NSSS methods for calculating Kim and Kit factors, as stated in Section 5.4 of CE NPSD-683, Revision 6, are being used as the basis for generating the P-T limits for their facilities) apply for an exemption against requirements of Section IV.A.2 of Appendix G to Part 50 to apply the CE NSSS methods to their P-T curves.This is consistent with the 'note" on page 5-15 of CE NPSD-683, Revision 6. Exemption requests to apply the CE NSSS to the generation of P-T limit curves should be submitted pursuant to the provision of 10 CFR 50.60(b) and will be evaluated on a case-by-case basis against the exem ption request acceptance criteria of 10 CFR 50.12; and Assessment:
An Exemption is requested for the application of the CE NSSS P-T methodology to generate P-T limits for St. Lucie Unit 1.
L-2011-076 Attachment 2 Page 5 of 5 (22) Include in their PTLRs the P-T curves for heatup, cooldown, criticality, and hydrostatic and leak tests of their reactors.Assessment:
This item is not applicable to St. Lucie Unit 1 as it does not have a PTLR.No response required for a submittal that is not requesting approval of a PTLR.Information needed to satisfy Criterion 6 of the Table in Attachment 7 to GL 96-03, which deals with the topic of describing how the P-T limit curves for normal operations and pressure testing conditions will satisfy the appropriate minimum temperature requirements, as stated in Table 1 of Appendix G to Part 50 -Licensees will need to: (23) Demonstrate how the P-T curves for pressure testing conditions and normal operations with the core critical and not-critical will be in compliance with the appropriate minimum temperature requirements as given in Table 1 to Appendix G to Part 50.Assessment:
Item 23 was considered in generating the P-T limits for St. Lucie Unit 1 in addition to the CE N SSS P-T methodology.
No response required for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP describes the hydrostatic and core critical limits in Section 2.6.Information needed to satisfy Criterion 7 of the Table in Attachment 7 to GL 96-03, which deals with the topic of how the plant-specific RPV material surveillance data will be evaluated and applied to the adj usted reference temperature calculations
-Licensees will need to: (24) Include in their PTLRs the supplemental surveillance data and calculations of the chemistry factors if surveillance data are used for the calculations of the adjusted reference temperatures; (25) Provide the evaluation of whether the surveillance data are credible in accordance with the credibility criteria of RG 1.99, Revision 2;(26) In addition, if licensees seek to use surveillance data from supplemental plant sources, licensees must: (a) Identify the source(s) of the data; and (b) Either identify by title and number the safety evaluation report that approved the use of the supplemental data, along with a justification of why the data is applicable; or compare the licensee's (applicant's) data with the data from the supplemental plant(s) for both the radiation environments (i.e., neutron spectrums and irradiation temperatures) and the surveillance test results, and pursuant to Section 111.C of Appendix H to Part 50, submit the proposed integrated surveillance program and evaluation of the data to the NRC for review and approval.Assessment:
Items 24 through 26(b) do not provide information necessary to support the P-T limit methodology -this information supports surveillance data evaluation.
No response required for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP describes the surveillance data and RG 1.99 in Section 2.1.
L-2011-076 Attachment 3 Page 1 of 8 Attachment 3 Application for Withholding Proprietary Information from Public Disclosure (Westinghouse Letter CAW-1 1-3065 next 7 pages)
S )Westinghouse Westinghouse Electric Company Nuclear Services 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Direct tel: Direct fax: e-mail: Proj letter: (412) 374-4643 (724) 720-0754 greshaja@wvestinghouse.com CAW-l 1-3065 February 3,2011 APPLICATION FOR WITHHOLDING PROPRIETARY INFORMATION FROM PUBLIC DISCLOSURE
 
==Subject:==
Information Responding to NRC's RAI on the St. Lucie Unit I EPU License Amendment Request (Proprietary) (Submitted for Approval)The proprietary information for which withholding is being requested in the above-refe'renced response to a NRC request for additional information (RAI) is fuirther identified in Affidavit CAW-] 1-3065 signed by the owner of the proprietary information, Westinghouse Electric Company LLC. The affidavit, which accompanies this letter, sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4)of 10 CFR Section 2.390 of the Commission's regulations.
Accordingly, this letter authorizes the utilization of the accompanying affidavit by Florida Power and Light.Correspondence with respect to the proprietary aspects of the application for withholding or the Westinghouse affidavit should reference this letter, CAW-l 1-3065, and should be addressed to J. A.Gresharn, Manager, Regulatory Compliance and Plant Licensing, Westinghouse Electric Company LLC, Suite 428, 1000 Westinghouse Drive, Cranberry Township, Pennsylvania 16066.Very truly yours, J. A. Gresham, Manager Regulatory Compliance and Plant Licensing Enclosures CAW- 11 -3065 AFFIDAVIT STATE OF CONNECTICUT:
ss S/0/ '4so A 2ockS COUNTY OF HARTFORD: Before me, the undersigned authority, personally appeared C. M. Molnar, who, being by me duly sworn according to law, deposes and says that he is authorized to execute this Affidavit on behalf of Westinghouse Electric Company LLC (Westinghouse), and that the averments of fact set forth in this Affidavit are true and correct to the best of his knowledge, information, and belief: C. M. Molnar, Senior Engineer Regulatory Compliance and Plant Licensing Sworn to arid subscribed before me this 3g day of 2011 Notary Public ,;ubscco ..id -..... " -)efore me, a Notary Public, in and iki.-County of I-artford and SIte of Connectnut.
this day of 20 .4L.JOAN GRAY Not.,,.rjj Public My Commission Expircs January 31, 2012 2 CAW-] 1-3065 (I) I am Senior Engineer, Regulatory Compliance and Plant Licensing, in Nuclear Services, Westinghouse Electric Company LLC (Westinghouse), and as.such. I have been specifically delegated the function of reviewing the proprietary information sought to be withheld fromn public disclosure in connection with nuclear power plant licensing and rule making proceedings, and am authorized to apply for its withholding on behalf of Westinghouse.
(2) 1 am making this Affidavit in conformance with the provisions of 10 CFR Section 2.390 of the Commission's regulations and in conljunction with the Westinghouse Application for Withholding Proprietary Information from Public Disclosure accompanying this Affidavit.
(3) 1 have personal knowledge of the criteria and procedures utilized by Westinghouse in designating information as a trade secret, privileged or as confidential commercial or financial information.
(4) Pursuant to the provisions of paragraph (b)(4) of Section 2.390 of the Commission's regulations, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld.(i) The information sought to be withheld fi-om public disclosure is owned and has been held in confidence by Westinghouse.(ii) The information is of a type customarily held in confidence by Westinghouse and not customarily disclosed to the public. Westinghouse has a rational basis for determining the types of information customarily held in confidence by it and, in that connection, utilizes a system to determine when and whether to hold certain types of information in confidence.
The application of that system and the substance of that system constitutes Westinghouse policy and provides the rational basis required.Under that system, information is held in confidence if it falls in one or more of several types, the release of which might resuLlt in the loss of an existing or potential competitive advantage, as follows: (a) Thle information reveals the distinguishing aspects of a process (or component, structure, tool, method, etc.) where prevention of its use by any of 3 CAW-1 -3065 Westinghouse's competitors without license firom WestinghoLise constitutes a competitive economic advantage over other companies.(b) It consists of supporting data, including test data, relative to a process (or component, structure.
tool, method, etc.), the application of which data secures a competitive economic advantage, e.g., by optimization or improved marketability.(c) Its use by a competitor would reduce his expenditure of resources or improve his competitive position in the design, manuf-acture, shipment, installation, assurance of quality, or licensing a similar product.(d) It reveals cost or price information, production capacities, budget levels, or commercial strategies of Westinghouse, its customers or suppliers.(e) It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse.(f) It contains patentable ideas, for which patent protection may be desirable.
There are sound policy reasons behind the Westinghouse system which include the following: (a) The use of such information by Westinghouse gives Westinghouse a competitive advantage over its competitors.
It is, therefore, withheld from disclosure to protect the Westinghouse competitive position.(b) It is information that is marketable in many ways. The extent to which such information is available to competitors diminishes the Westinghouse ability to sell products and services involving the use of the information.(c) Use by our competitor would put Westinghouse at a competitive disadvantage by reducing his expenditure of resources at our expense.
4 CAW-] 1-3065 (d) Each component of proprietary information i)ertilnent to a particular competitive advantage is potentially as valuable as the total competitive advantage.
If competitors acquire components of proprietary information, any one component may be the key to the entire puzzle, thereby depriving Westinghouse of a competitive advantage.(e) Unrestricted disclosure would jeopardize the position of prominence of Westinghouse inl the world market, and thereby give a market advantage to the competition of those countries.(f) The Westinghouse capacity to invest corporate assets in research and development depends upon the success in obtaining and maintaining a competitive advantage.(iii) The information is being transmitted to the Commission in confidence and, under the provisions of 10 CFR Section 2.390; it is to be received in confidence by the Commission.(iv) The information sought to be protected is not available in public sources or available information has not been previously employed in the same original manner or method to the best of our knowledge and belief.(v) The proprietary information sought to be withheld in this submittal is that which is appropriately marked in Florida Power and Light's responses to NRC requests for additional information regarding pressure/temperature limits in the St. Lucie Unit I extended power uprate license amendment request for submittal to the Commission, being transmitted by FPL letter and Application for Withholding Proprietary Information from Public Disclosure, to the Document Control Desk. The proprietary information as submitted by Westinghouse is that associated with KIM influence coefficients due to unit internal pressure for 1/4t inside and 1/4t outside surface flaw and may be used only for that purpose.
5 CAW-1 1-3065 Tills information is part of that which will enable WestinIghouse to: (a) Support the St. Lucie Unit I extended power uprate license amendment request.Further this infornlation has substantial commercial value as follows: (a) Westinghouse plans to sell the use of similar information to its customers for the purpose of justifying the acceptability of pressure/temperature limits.(b) Westinghouse can sell support and defense of' its methodology for developing pressure/temperature Iiminits.Public disclosure of this proprietary information is likely to cause substantial harm to the competitive position of Westinghouse because it Would enhance the ability of competitors to provide similar information and licensing defense services for commercial power reactors without commensurate expenses.
Also, public disclosure of the information would enable others to use the information to meet NRC requirements for licensing documentation without purchasing the right to use the information.
The development of the technology described in part by the information is the result of applying the results of many years of experience in an intensive Westinghouse effort and the expenditure of a considerable sum of money.In order for competitors of Westinghouse to duplicate this information, similar technical programs would have to be performed and a significant manpower effort, having the requisite talent and experience, would have to be expended.Further the deponent sayeth not.
PROPRIETARY INFORMATION NOTICE Transmitted herewith are proprietary and/or non-proprietary versions of docunlents furnished to the NRC in connection with requests for generic and/or plant-specific review and approval.In order to confornm to the requiremnents of 10 CFR 2.390 of the Commission' s regulations concerning the protection of proprietary information so submitted to the NRC, the information which is proprietary in the proprietary versions is contained within brackets, and where the proprietary information has been deleted in the non-proprietary versions, only the brackets remain (the information that was contained within the brackets in the proprietary versions having been deleted).
The justification for claiming the information so designated as proprietary is indicated in both versions by means of lower case letters (a) through (t)located as a superscript immediately following the brackets enclosing each item of information being identified as proprietary or ini the margin opposite such information.
These lower case letters refer to the types of information Westinghouse customarily holds in confidence identified in Sections (4)(ii)(a) through (4)(ii)(f) of the affidavit accompanying this transmittal pursuant to 10 CFR 2.390(b)( I).COPYRIGHT NOTICE The reports transmitted herewith each bear a Westinghouse copyright notice. The NRC is permitted to make the number of copies of the information contained in these reports which are necessary for its internal use in connection with generic and plant-specific reviews and approvals as well as the issuance, denial, amendment, transfer, renewal, modification, suspension, revocation, or violation of a license, permit, order, or regulation subject to the requirements of 10 CFR 2.390 regarding restrictions on public disclosure to the extent such information has been identified as proprietary by Westinghouse, copyright protection notwithstanding.
With respect to the non-proprietary versions of these reports, the NRC is permitted to make the number of copies beyond those necessary for its internal use which are necessary ill order to have one copy available for public viewing in the appropriate docket files in the public document room in Washington, DC and in local public document rooms as may be required by NRC regulations if the number of copies submitted is insufficient for this purpose. Copies made by the NRC must include the copyright notice in all instances and the proprietary notice if the original was identified as proprietary.
L-2011-076 Attachment 4 Page 1 of 8 Attachment 4 Stress Intensity Factors (Non-Proprietary)
L-2011-076 Attachment 4 Page 2 of 8 Crack Tip Stress Intensity Factors for Mechanical (KIM ) and Thermal (Kithermal) for 114t Inside and 1/4t Outside Surface Flaw The KIT values in this Attachment were calculated using CE NPSD-683-A, Revision 6 methodology.
The information in this Attachment is that requested by NRC for their review.Table of KiM Influence Coefficients due to unit (lksi) Internal Pressure Crack Location Kip (ksi'/in)1/4t Inside 1/4t Outside (a,c)-J L-2011-076 Attachment 4 Page 3 of 8 Table of KIT Values Heatup Cooldown Fluid 50°F/hr 70°F/hr 20°F/hr 30°F/hr 40°F/hr 50°F/hr 100°F/hr Temperature outside outside Inside Inside Inside Inside Inside (7F) (ksi0in) (ksi0in) (ksiin) (ksi0in) (ksi.in) (ks9in) (ksi2in)70 0 0 4.650 6.974 9.299 11.624 23.223 80 1.380 1.250 4.650 6.974 9.299 11.624 23.220 90 3.008 2.963 4.650 6.974 9.299 11.624 23.215 100 4.351 4.532 4.650 6.974 9.299 11.624 23.210 110 5.344 5.853 4.650 6.974 9.299 11.624 23.204 120 6.108 6.943 4.650 6.974 9.299 11.624 23.197 130 6.695 7.837 4.650 6.974 9.299 11.624 23.189 140 7.122 8.569 4.650 6.974 9.299 11.624 23.180 150 7.451 9.165 4.650 6.974 9.299 11.624 23.170 160 7.703 9.653 4.650 6.974 9.299 11.624 23.157 170 7.886 10.053 4.650 6.974 9.299 11.624 23.143 180 8.027 10.379 4.650 6.974 9.299 11.624 23.127 190 8.136 10.647 4.650 6.974 9.299 11.624 23.108 200 8.214 10.866 4.650 6.974 9.299 11.623 23.086 200 8.214 10.866 4.650 6.974 9.299 11.623 23.086 210 8.275 11.045 4.650 6.974 9.299 11.623 23.061 220 8.322 11.190 4.650 6.974 9.299 11.623 23.032 230 8.355 11.310 4.650 6.974 9.299 11.623 22.999 240 8.382 11.408 4.650 6.974 9.299 11.622 22.960 250 8.401 11.488 4.650 6.974 9.299 11.621 22.916 260 8.416 11.553 4.650 6.974 9.299 11.621 22.864 270 8.427 11.606 4.650 6.974 9.299 11.619 22.804 280 8.436 11.650 4.650 6.974 9.299 11.618 22.736 290 8.442 11.686 4.650 6.974 9.298 11.616 22.656 300 8.447 11.715 4.650 6.974 9.298 11.613 22.564 310 8.451 11.739 4.650 6.974 9.297 11.610 22.458 320 8.453 11.759 4.650 6.974 9.296 11.605 22.336 330 8.455 11.775 4.650 6.974 9.295 11.598 22.194 340 8.457 11.788 4.650 6.974 9.293 11.590 22.031 350 8.458 11.798 4.650 6.974 9.290 11.579 21.842 360 8.459 11.807 4.650 6.973 9.287 11.564 21.624 370 8.460 11.814 4.650 6.973 9.282 11.545 21.372 380 8.460 11.820 4.650 6.972 9.274 11.519 21.081 390 8.460 11.825 4.650 6.970 9.263 11.485 20.745 400 8.461 11.829 4.650 6.968 9.248 11.440 20.357 410 8.461 11.832 4.649 6.964 9.226 11.379 19.909 420 8.461 11.835 4.649 6.957 9.195 11.300 19.391 430 8.461 11.837 4.649 6.948 9.152 11.196 18.793 440 8.461 11.838 4.647 6.931 9.089 11.054 18.103 450 8.461 11.840 4.645 6.905 9.000 10.869 17.305 460 8.461 11.841 4.641 6.864 8.877 10.628 16.383 470 8.462 11.842 4.632 6.797 8.695 10.298 15.319 L-2011-076 Attachment 4 Page 4 of 8 480 8.462 11.843 4.613 6.690 8.440 9.866 14.089 490 8.462 11.843 4.576 6.524 8.084 9.306 12.670 500 8.462 11.844 4.500 6.247 7.562 8.536 11.032 510 8.462 11.844 4.349 5.811 6.829 7.533 9.145 520 8.462 11.845 4.036 5.131 5.804 6.229 6.983 530 8.462 11.845 3.421 4.002 4.309 4.452 4.548 540 8.462 11.845 2.143 2.242 2.259 2.222 1.960 550 8.462 11.845 0 0 0 0 0 L-2011-076 Attachment 4 Page 5 of 8 FP&L SL-1 Kithermal for 1/4t Outside Surface Flaw -Heatup Transients C E 20 18 16 14 12 10 8 6 4 2 0-50F/hr outside-70*F/hr outside 0 50 100 150 200 250 300 Coolant Temperature
(°F)350 400 450 500 550 L-2011-076 Attachment 4 Page 6 of 8 25 20 15 10 FP&L SL-1 Kithermal for 1/4t Inside Surface Flaw -Cooldown Transients
-20*F/hr Inside.... 30*F/hr Inside 40°F/hr Inside-50F/hr Inside-lO0°F/hr Inside 0 0 50 100 150 200 250 300 Coolant Temperature (F)350 400 450 500 550 L-2011-076 Attachment 4 Page 7 of 8 FP&L SL-1 (Tfluid-Tcrack tip) for 114t Outside Surface Flaw Heatup Transients 60 55 50 45 40-35 30 2 0 15 10 5 0 0 60 120 180 240 300 360 420 480 540 600 Time(min)
L-2011-076 Attachment 4 Page 8 of 8 FP&L SL-1 (Tcrack tip-Tfluid ) for 114t Inside Surface Flaw Cooldown Transients U.12 a..60 55 50 45 40 35 30 25 20 15 10 5 0 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 Time (min)}}

Revision as of 17:33, 18 March 2019

St. Lucie, Unit 1 - Response to NRC Request for Additional Information (RAI) Regarding Extended Power Uprate License Amendment Request
ML110600706
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 02/25/2011
From: Anderson R L
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2011-076
Download: ML110600706 (24)


Text

Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 February 25, 2011 FlPL This letter forwards proprietary information in accordance with 10 CFR 2.390. The balance of this letter may be considered non-proprietary upon removal of Attachment 1.L-2011-076 10 CFR 50.90 U.S, Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Re: St. Lucie Plant Unit I Docket No. 50-335 Renewed Facility Operating License No. DPR-67 Response to NRC Request for Additional Information (RAI) Regarding Extended Power Uprate License Amendment Request

References:

(1) R. L. Anderson (FPL) to U.S. Nuclear Regulatory Commission (L-2010-259),"License Amendment Request for Extended Power Uprate, November 22, 2010, Accession No. ML103560419.

(2) Email from T. Orf (NRC) to C. Wasik (FPL), "Requested St. Lucie Unit I EPU Information," January 13, 2011, Accession No. ML 110130412.

(3) Westinghouse Report, CE-NPSD-683-A Task-i 174, Revision 06, "Development of a RCS Pressure and Temperature Limits Report for the Removal of P-T Limits and LTOP requirements from the Technical Specifications," April 2001, Accession No. MLO0113503871.

By letter L-2010-259 dated November 22, 2010 [Reference 1], Florida Power & Light Company (FPL) requested to amend Renewed Facility Operating License No. DPR-67 and revise the St. Lucie Unit 1 Technical Specifications (TS). The proposed amendment will increase the unit's licensed core thermal power level from 2700 megawatts thermal (MWt) to 3020 MWt and revise the Renewed Facility Operating License and TS to support operation at this increased core thermal power level. This represents an approximate increase of 11.85% and is therefore considered an extended power uprate (EPU).By email from the NRC Project Manager dated January 13, 2011 [Reference 2], additional information regarding the analysis supporting proposed changes to the reactor coolant system pressure-temperature (P-T) limits was requested by the NRC staff in the Vessels and Internals Integrity Branch (CVIB) to support their review of the EPU LAR.A-oc5I an FPL Group company L-2011-076 Page 2 of 3 The request for additional information (RAI) identified that an exemption request related to the use of methodology contained within the Reference 3 topical report is required.The RAI also requested a tabulation of stress intensity factors (K values) used to generate the P-T limits. The tabulation of stress intensity factors, along with related curves, is provided in Attachment 1 to this letter. The exemption request will be provided under separate cover.The Reference 2 RAI email notes that FPL will provide, with the exemption request, responses to the supplemental information questions listed in the Reference 3 topical report and/or identify which questions do not apply; however, in a telephone conference between FPL and the NRC on January 19, 2011, it was agreed that the response to the supplemental information questions would not be included with the exemption request, but would be submitted along with the tabulation of stress intensity values. Attachment 2 to this letter provides responses to the supplemental information questions.

Attachment 3 contains the application for withholding proprietary information contained in Attachment 1 from public disclosure.

As Attachment 1 contains information proprietary to Westinghouse Electric Company, LLC (Westinghouse), it is supported by an affidavit signed by Westinghouse, the owner of the information.

The affidavit sets forth the basis for which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4)of §2.3 90 of the Commission's' regulations.

Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR 2.390 of the Commission's regulations.

Correspondence with respect to the copyright or proprietary aspects of Attachment 1 of this letter or the supporting Westinghouse affidavit should reference CAW-1 1-3065 and should be addressed to J. A. Gresham, Manager, Regulatory Compliance and Plant Licensing, Westinghouse Electric Company LLC, Suite 428, 1000 Westinghouse Drive, Cranberry Township, PA 16066.Attachment 4 provides a public version of the Attachment 1 tabulation of stress intensity factors and related curves.In accordance with 10 CFR 50.9 1(b)(1), a copy of this letter is being forwarded to the Designated State of Florida official.This submittal does not alter the significant hazards consideration or environmental assessment previously submitted by FPL letter L-2010-259

[Reference 1].This submittal contains no new commitments and no revisions to existing commitments.

Should you have any questions regarding this submittal, please contact Mr. Christopher Wasik, St. Lucie Extended Power Uprate LAR Project Manager, at 772-429-7138.

L-2011-076 Page 3 of 3 1 declare under penalty of perjury that the foregoing is true and correct to the best of my knowledge.

Executed on ,e- ,,, 2 Very truly yours, Richard L. Anderson Site Vice President St. Lucie Plant Attachments cc: Administrator, Region II, USNRC Project Manager, St. Lucie Nuclear Plant, USNRC Senior Resident Inspector, St. Lucie Nuclear Plant, USNRC Mr. William Passetti, Florida Department of Health L-2011-076 Attachment 2 Page 1 of 5 Attachment 2 Responses to Supplemental Information Requirements L-2011-076 Attachment 2 Page 2 of 5 Discussion Section 5.0 of the NRC Safety Evaluation (SE) for CE-NPSD-683-A contains twenty-six items of information to be included in pressure-temperature limits report (PTLR) License Amendment Requests to satisfy the criteria of the table in Attachment 1 to Generic Letter (GL) 96-03. GL 96-03, "Relocation of the Pressure Temperature Limit Curves and Low Temperature Overpressure Protection System Limits," provides guidance on relocating the pressure-temperature (P-T) limits and certain low temperature overpressure protection (LTO P) controls from the Technical Specifications to a PTLR. The table in Attachment 1 to GL 96-03 contains information requirements related to the methodology for generating P-T limits and LTOP setpoints.

Florida Power and Light (FPL), in their St. Lucie Unit I (PSL1) Extended Power Uprate (EPU)License Amendment Request (LAR), requests approval of changes to the P-T limits based on CE-NPSD-683-A methodology.

The technical basis for the new P-T limits and the basis and methodology for the LTOP evaluation that is supported by the proposed P-T limits is described in the Westinghouse document WCAP-17197-NP.

WCAP-17197-NP was prepared by Westinghouse and provided to FPL to support the proposed PS Li P-T limits described in the EPU LAR.Although FPL is not requesting that the PS LI P-T limits be relocated to a PTLR, since FPL is using the P-T limits methodology from CE-NPSD-683-A for St. Lucie Unit 1, each of the twenty-six information items from Section 5.0 of the CE-NPSD-683-A safety evaluation (SE) is stated below along with an assessment of the applicable proposed change to the St. Lucie Unit 1 P-T limits.Information Items from Section 5.0 of the CE-NPSD-683-A SE Information needed to satisfy Criterion 1 of the Table in Attachment I to GL 96-03, which deals with the topic of neutron fluence calculational methods -Licensees will need to: (1) Describe the methodology used to calculate the neutron fluence values for the reactor vessel materials, including a description of whether or not the methodology is consistent with the guidance of Draft Regulatory Guide DG-1 053, a description of the computer codes used to calculate the neutron fluence values, and a description of how the computer codes for calculating the neutron fluence values were benchmarked; and (2) Provide the values of neutron fluence used for the adjusted reference temperature (RT1OT) calculations, including the values of neutron fluence for the ihner surface (ID), 1/4T and 3/4T locations of the RPV.Assessment:

Items 1 and 2 do not provide information necessary to support the P-T limit methodology

-this information supports fluence determination.

No response required -for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP does not describe the methodology to calculate neutron fluence.Information needed to satisfy Criterion 2 of the Table in Attachment 7 to GL 96-03, which deals with the topic of reactor vessel material surveillance program designs and withdrawal schedules

-Licensees will need to:

L-2011-076 Attachment 2 Page 3 of 5 (3) Either provide the surveillance capsule withdrawal schedule in the proposed PTLR for the amendment or reference in the PTLR by title and number the documents in which the withdrawal schedule is located; and (4) Reference the surveillance capsule reports by title and number if the RTNDr values are calculated using RPV surveillance capsule data.Assessment:

Items 3 and 4 do not provide information necessary to support the P-T limit methodology

-this information supports the surveillance capsule schedule and report information.

No response required for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP does not describe the surveillance capsule withdrawal schedule or reports.Information needed to satisfy Criterion 3 of the Table in Attachment I to GL 96-03, which deals with the topic of describing the methodologies that will be used to establish the LTOP system limits -Licensees will need to: (5) Provide a description of the analytical method used in the energy addition transient analysis;(6) Provide a description of the analytical method used in the mass addition transient analysis, if different from that in Section 3.3.5 of the topical report;(7) Provide a description of the method for selection of relief valve setpoints; (8) Provide a justification for use of subcooled water conditions or a steam volume in the pressurizer; (9) Provide a justification for a less conservative method for determination of decay heat contribution if the method used is less conservative than the "most conservative method" described in the topical report;(10) Provide justification for operator action time used in transient mitigation or termination; (11) Provide correlations used for developing PORV discharge characteristics; (12) Provide spring relief valve discharge characteristics if different from those described in the topical report or if the peak transient pressure is above the set pressure of the valve plus 10 percent;(13) Provide a description of how the reactor coolant temperature instrumentation uncertainty was accounted for;(14) Provide a justification for the mass and energy addition transient mitigation which credit presence of nitrogen in the pressurizer; and (15) Identify and explain any other deviation from the methodology included in Section 3.0 of the topical report.Assessment:

Items 5 through 15 do not provide information necessary to support the P-T limit methodology

-this information supports LTOP Evaluation methods. No response required for a submittal that is not requesting approval of a PTLR.WCAP-1 7197-NP describes LTOP transient methods and assumptions in Sections 3.2 and 3.3.Information needed to satisfy Criterion 4 of the Table in Attachment I to GL 96-03, which deals with the topic of describing the methodologies that will be used to calculate the adjusted reference temperature values for the RPV materials

-Licensees will need to: (16) Identify the limiting materials and corresponding RTNDT values for both the quarter thickness (1/4T) and three-quarter-thickness (3/4T) locations of the RPV shell; and (17) For pressurized-water-reactor (PWR) design facilities, identify the limiting RTNDT value for RPV as calculated in accordance with the methods and criteria of 10 CFR 50.61.

L-2011-076 Attachment 2 Page 4 of 5 Assessment:

Items 16 and 17 do not provide information necessary to support the P-T limit methodology

-this information supports material property information.

No response required, for a submittal that is not requesting approval of a PTLR.WCAP-1 7197-NP describes the adjusted reference temperature in Section 2.1.Information needed to satisfy Criterion 5 of the Table in Attachment I to GL 96-03, which deals with the topic of describing the methodologies used to generate plant specific P-T limit curves -Licensees will need to: (18) Ensure that the ferritic RPV materials that have accumulated neutron fluences in excess of 1.0x1017 n/cm 2 (E > 1 MeV) will be assessed according to Section 4.0 of the CE Topical Report CE NPSD-683, Revision 6, regardless of whether the materials are located within the region immediately surrounding the active core;Assessment:

This item is not related to the C-E NPSD-683 P-T methodology.

No response required, for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP describes the material fluence projections in Section 2.1.(19) Identify which method (i.e., Kic or KIA) will be used to calculate the reference intensity factor (KIR) values for the RPV as a function of temperature; Assessment:

ASME Code has since been updated to use Kic criteria and, hence, was used in generating the St. Lucie Unit 1 P-T limits.(20) (Applicable only if Code Case N-640 and Kc are used as the basis for calculating the KIR values) submit an exemption request [pursuant to alternative program provisions of 10 CFR 50.60(b)]

to use the methods of Code Case N-640 and apply them to the P-T limit calculations.

Note that the staff will approve an exemption request to use Code Case N-640 and K 1 c as the bases for generating the P-T limit curves only if a licensee indicates that it will limit the maximum pressure in the vessel to 100 percent of the pressure satisfying Paragraph G-2215 of the 1996 Edition of Appendix G to the Code for establishing LTOP limit setpoints.

This condition is consistent with Note (2) on page 5-6 of CE NPSD-683, Revision 6;Assessment:

The 2004 Edition of the American Society of Mechanical Engineers (ASME) Code codified in the Code of Federal Regulations has incorporated the use of Kc criteria.

No response required.(21) (Applicable only if the CE NSSS methods for calculating Kim and Kit factors, as stated in Section 5.4 of CE NPSD-683, Revision 6, are being used as the basis for generating the P-T limits for their facilities) apply for an exemption against requirements of Section IV.A.2 of Appendix G to Part 50 to apply the CE NSSS methods to their P-T curves.This is consistent with the 'note" on page 5-15 of CE NPSD-683, Revision 6. Exemption requests to apply the CE NSSS to the generation of P-T limit curves should be submitted pursuant to the provision of 10 CFR 50.60(b) and will be evaluated on a case-by-case basis against the exem ption request acceptance criteria of 10 CFR 50.12; and Assessment:

An Exemption is requested for the application of the CE NSSS P-T methodology to generate P-T limits for St. Lucie Unit 1.

L-2011-076 Attachment 2 Page 5 of 5 (22) Include in their PTLRs the P-T curves for heatup, cooldown, criticality, and hydrostatic and leak tests of their reactors.Assessment:

This item is not applicable to St. Lucie Unit 1 as it does not have a PTLR.No response required for a submittal that is not requesting approval of a PTLR.Information needed to satisfy Criterion 6 of the Table in Attachment 7 to GL 96-03, which deals with the topic of describing how the P-T limit curves for normal operations and pressure testing conditions will satisfy the appropriate minimum temperature requirements, as stated in Table 1 of Appendix G to Part 50 -Licensees will need to: (23) Demonstrate how the P-T curves for pressure testing conditions and normal operations with the core critical and not-critical will be in compliance with the appropriate minimum temperature requirements as given in Table 1 to Appendix G to Part 50.Assessment:

Item 23 was considered in generating the P-T limits for St. Lucie Unit 1 in addition to the CE N SSS P-T methodology.

No response required for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP describes the hydrostatic and core critical limits in Section 2.6.Information needed to satisfy Criterion 7 of the Table in Attachment 7 to GL 96-03, which deals with the topic of how the plant-specific RPV material surveillance data will be evaluated and applied to the adj usted reference temperature calculations

-Licensees will need to: (24) Include in their PTLRs the supplemental surveillance data and calculations of the chemistry factors if surveillance data are used for the calculations of the adjusted reference temperatures; (25) Provide the evaluation of whether the surveillance data are credible in accordance with the credibility criteria of RG 1.99, Revision 2;(26) In addition, if licensees seek to use surveillance data from supplemental plant sources, licensees must: (a) Identify the source(s) of the data; and (b) Either identify by title and number the safety evaluation report that approved the use of the supplemental data, along with a justification of why the data is applicable; or compare the licensee's (applicant's) data with the data from the supplemental plant(s) for both the radiation environments (i.e., neutron spectrums and irradiation temperatures) and the surveillance test results, and pursuant to Section 111.C of Appendix H to Part 50, submit the proposed integrated surveillance program and evaluation of the data to the NRC for review and approval.Assessment:

Items 24 through 26(b) do not provide information necessary to support the P-T limit methodology -this information supports surveillance data evaluation.

No response required for a submittal that is not requesting approval of a PTLR. WCAP-17197-NP describes the surveillance data and RG 1.99 in Section 2.1.

L-2011-076 Attachment 3 Page 1 of 8 Attachment 3 Application for Withholding Proprietary Information from Public Disclosure (Westinghouse Letter CAW-1 1-3065 next 7 pages)

S )Westinghouse Westinghouse Electric Company Nuclear Services 1000 Westinghouse Drive Cranberry Township, Pennsylvania 16066 USA U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Direct tel: Direct fax: e-mail: Proj letter: (412) 374-4643 (724) 720-0754 greshaja@wvestinghouse.com CAW-l 1-3065 February 3,2011 APPLICATION FOR WITHHOLDING PROPRIETARY INFORMATION FROM PUBLIC DISCLOSURE

Subject:

Information Responding to NRC's RAI on the St. Lucie Unit I EPU License Amendment Request (Proprietary) (Submitted for Approval)The proprietary information for which withholding is being requested in the above-refe'renced response to a NRC request for additional information (RAI) is fuirther identified in Affidavit CAW-] 1-3065 signed by the owner of the proprietary information, Westinghouse Electric Company LLC. The affidavit, which accompanies this letter, sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4)of 10 CFR Section 2.390 of the Commission's regulations.

Accordingly, this letter authorizes the utilization of the accompanying affidavit by Florida Power and Light.Correspondence with respect to the proprietary aspects of the application for withholding or the Westinghouse affidavit should reference this letter, CAW-l 1-3065, and should be addressed to J. A.Gresharn, Manager, Regulatory Compliance and Plant Licensing, Westinghouse Electric Company LLC, Suite 428, 1000 Westinghouse Drive, Cranberry Township, Pennsylvania 16066.Very truly yours, J. A. Gresham, Manager Regulatory Compliance and Plant Licensing Enclosures CAW- 11 -3065 AFFIDAVIT STATE OF CONNECTICUT:

ss S/0/ '4so A 2ockS COUNTY OF HARTFORD: Before me, the undersigned authority, personally appeared C. M. Molnar, who, being by me duly sworn according to law, deposes and says that he is authorized to execute this Affidavit on behalf of Westinghouse Electric Company LLC (Westinghouse), and that the averments of fact set forth in this Affidavit are true and correct to the best of his knowledge, information, and belief: C. M. Molnar, Senior Engineer Regulatory Compliance and Plant Licensing Sworn to arid subscribed before me this 3g day of 2011 Notary Public ,;ubscco ..id -..... " -)efore me, a Notary Public, in and iki.-County of I-artford and SIte of Connectnut.

this day of 20 .4L.JOAN GRAY Not.,,.rjj Public My Commission Expircs January 31, 2012 2 CAW-] 1-3065 (I) I am Senior Engineer, Regulatory Compliance and Plant Licensing, in Nuclear Services, Westinghouse Electric Company LLC (Westinghouse), and as.such. I have been specifically delegated the function of reviewing the proprietary information sought to be withheld fromn public disclosure in connection with nuclear power plant licensing and rule making proceedings, and am authorized to apply for its withholding on behalf of Westinghouse.

(2) 1 am making this Affidavit in conformance with the provisions of 10 CFR Section 2.390 of the Commission's regulations and in conljunction with the Westinghouse Application for Withholding Proprietary Information from Public Disclosure accompanying this Affidavit.

(3) 1 have personal knowledge of the criteria and procedures utilized by Westinghouse in designating information as a trade secret, privileged or as confidential commercial or financial information.

(4) Pursuant to the provisions of paragraph (b)(4) of Section 2.390 of the Commission's regulations, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld.(i) The information sought to be withheld fi-om public disclosure is owned and has been held in confidence by Westinghouse.(ii) The information is of a type customarily held in confidence by Westinghouse and not customarily disclosed to the public. Westinghouse has a rational basis for determining the types of information customarily held in confidence by it and, in that connection, utilizes a system to determine when and whether to hold certain types of information in confidence.

The application of that system and the substance of that system constitutes Westinghouse policy and provides the rational basis required.Under that system, information is held in confidence if it falls in one or more of several types, the release of which might resuLlt in the loss of an existing or potential competitive advantage, as follows: (a) Thle information reveals the distinguishing aspects of a process (or component, structure, tool, method, etc.) where prevention of its use by any of 3 CAW-1 -3065 Westinghouse's competitors without license firom WestinghoLise constitutes a competitive economic advantage over other companies.(b) It consists of supporting data, including test data, relative to a process (or component, structure.

tool, method, etc.), the application of which data secures a competitive economic advantage, e.g., by optimization or improved marketability.(c) Its use by a competitor would reduce his expenditure of resources or improve his competitive position in the design, manuf-acture, shipment, installation, assurance of quality, or licensing a similar product.(d) It reveals cost or price information, production capacities, budget levels, or commercial strategies of Westinghouse, its customers or suppliers.(e) It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse.(f) It contains patentable ideas, for which patent protection may be desirable.

There are sound policy reasons behind the Westinghouse system which include the following: (a) The use of such information by Westinghouse gives Westinghouse a competitive advantage over its competitors.

It is, therefore, withheld from disclosure to protect the Westinghouse competitive position.(b) It is information that is marketable in many ways. The extent to which such information is available to competitors diminishes the Westinghouse ability to sell products and services involving the use of the information.(c) Use by our competitor would put Westinghouse at a competitive disadvantage by reducing his expenditure of resources at our expense.

4 CAW-] 1-3065 (d) Each component of proprietary information i)ertilnent to a particular competitive advantage is potentially as valuable as the total competitive advantage.

If competitors acquire components of proprietary information, any one component may be the key to the entire puzzle, thereby depriving Westinghouse of a competitive advantage.(e) Unrestricted disclosure would jeopardize the position of prominence of Westinghouse inl the world market, and thereby give a market advantage to the competition of those countries.(f) The Westinghouse capacity to invest corporate assets in research and development depends upon the success in obtaining and maintaining a competitive advantage.(iii) The information is being transmitted to the Commission in confidence and, under the provisions of 10 CFR Section 2.390; it is to be received in confidence by the Commission.(iv) The information sought to be protected is not available in public sources or available information has not been previously employed in the same original manner or method to the best of our knowledge and belief.(v) The proprietary information sought to be withheld in this submittal is that which is appropriately marked in Florida Power and Light's responses to NRC requests for additional information regarding pressure/temperature limits in the St. Lucie Unit I extended power uprate license amendment request for submittal to the Commission, being transmitted by FPL letter and Application for Withholding Proprietary Information from Public Disclosure, to the Document Control Desk. The proprietary information as submitted by Westinghouse is that associated with KIM influence coefficients due to unit internal pressure for 1/4t inside and 1/4t outside surface flaw and may be used only for that purpose.

5 CAW-1 1-3065 Tills information is part of that which will enable WestinIghouse to: (a) Support the St. Lucie Unit I extended power uprate license amendment request.Further this infornlation has substantial commercial value as follows: (a) Westinghouse plans to sell the use of similar information to its customers for the purpose of justifying the acceptability of pressure/temperature limits.(b) Westinghouse can sell support and defense of' its methodology for developing pressure/temperature Iiminits.Public disclosure of this proprietary information is likely to cause substantial harm to the competitive position of Westinghouse because it Would enhance the ability of competitors to provide similar information and licensing defense services for commercial power reactors without commensurate expenses.

Also, public disclosure of the information would enable others to use the information to meet NRC requirements for licensing documentation without purchasing the right to use the information.

The development of the technology described in part by the information is the result of applying the results of many years of experience in an intensive Westinghouse effort and the expenditure of a considerable sum of money.In order for competitors of Westinghouse to duplicate this information, similar technical programs would have to be performed and a significant manpower effort, having the requisite talent and experience, would have to be expended.Further the deponent sayeth not.

PROPRIETARY INFORMATION NOTICE Transmitted herewith are proprietary and/or non-proprietary versions of docunlents furnished to the NRC in connection with requests for generic and/or plant-specific review and approval.In order to confornm to the requiremnents of 10 CFR 2.390 of the Commission' s regulations concerning the protection of proprietary information so submitted to the NRC, the information which is proprietary in the proprietary versions is contained within brackets, and where the proprietary information has been deleted in the non-proprietary versions, only the brackets remain (the information that was contained within the brackets in the proprietary versions having been deleted).

The justification for claiming the information so designated as proprietary is indicated in both versions by means of lower case letters (a) through (t)located as a superscript immediately following the brackets enclosing each item of information being identified as proprietary or ini the margin opposite such information.

These lower case letters refer to the types of information Westinghouse customarily holds in confidence identified in Sections (4)(ii)(a) through (4)(ii)(f) of the affidavit accompanying this transmittal pursuant to 10 CFR 2.390(b)( I).COPYRIGHT NOTICE The reports transmitted herewith each bear a Westinghouse copyright notice. The NRC is permitted to make the number of copies of the information contained in these reports which are necessary for its internal use in connection with generic and plant-specific reviews and approvals as well as the issuance, denial, amendment, transfer, renewal, modification, suspension, revocation, or violation of a license, permit, order, or regulation subject to the requirements of 10 CFR 2.390 regarding restrictions on public disclosure to the extent such information has been identified as proprietary by Westinghouse, copyright protection notwithstanding.

With respect to the non-proprietary versions of these reports, the NRC is permitted to make the number of copies beyond those necessary for its internal use which are necessary ill order to have one copy available for public viewing in the appropriate docket files in the public document room in Washington, DC and in local public document rooms as may be required by NRC regulations if the number of copies submitted is insufficient for this purpose. Copies made by the NRC must include the copyright notice in all instances and the proprietary notice if the original was identified as proprietary.

L-2011-076 Attachment 4 Page 1 of 8 Attachment 4 Stress Intensity Factors (Non-Proprietary)

L-2011-076 Attachment 4 Page 2 of 8 Crack Tip Stress Intensity Factors for Mechanical (KIM ) and Thermal (Kithermal) for 114t Inside and 1/4t Outside Surface Flaw The KIT values in this Attachment were calculated using CE NPSD-683-A, Revision 6 methodology.

The information in this Attachment is that requested by NRC for their review.Table of KiM Influence Coefficients due to unit (lksi) Internal Pressure Crack Location Kip (ksi'/in)1/4t Inside 1/4t Outside (a,c)-J L-2011-076 Attachment 4 Page 3 of 8 Table of KIT Values Heatup Cooldown Fluid 50°F/hr 70°F/hr 20°F/hr 30°F/hr 40°F/hr 50°F/hr 100°F/hr Temperature outside outside Inside Inside Inside Inside Inside (7F) (ksi0in) (ksi0in) (ksiin) (ksi0in) (ksi.in) (ks9in) (ksi2in)70 0 0 4.650 6.974 9.299 11.624 23.223 80 1.380 1.250 4.650 6.974 9.299 11.624 23.220 90 3.008 2.963 4.650 6.974 9.299 11.624 23.215 100 4.351 4.532 4.650 6.974 9.299 11.624 23.210 110 5.344 5.853 4.650 6.974 9.299 11.624 23.204 120 6.108 6.943 4.650 6.974 9.299 11.624 23.197 130 6.695 7.837 4.650 6.974 9.299 11.624 23.189 140 7.122 8.569 4.650 6.974 9.299 11.624 23.180 150 7.451 9.165 4.650 6.974 9.299 11.624 23.170 160 7.703 9.653 4.650 6.974 9.299 11.624 23.157 170 7.886 10.053 4.650 6.974 9.299 11.624 23.143 180 8.027 10.379 4.650 6.974 9.299 11.624 23.127 190 8.136 10.647 4.650 6.974 9.299 11.624 23.108 200 8.214 10.866 4.650 6.974 9.299 11.623 23.086 200 8.214 10.866 4.650 6.974 9.299 11.623 23.086 210 8.275 11.045 4.650 6.974 9.299 11.623 23.061 220 8.322 11.190 4.650 6.974 9.299 11.623 23.032 230 8.355 11.310 4.650 6.974 9.299 11.623 22.999 240 8.382 11.408 4.650 6.974 9.299 11.622 22.960 250 8.401 11.488 4.650 6.974 9.299 11.621 22.916 260 8.416 11.553 4.650 6.974 9.299 11.621 22.864 270 8.427 11.606 4.650 6.974 9.299 11.619 22.804 280 8.436 11.650 4.650 6.974 9.299 11.618 22.736 290 8.442 11.686 4.650 6.974 9.298 11.616 22.656 300 8.447 11.715 4.650 6.974 9.298 11.613 22.564 310 8.451 11.739 4.650 6.974 9.297 11.610 22.458 320 8.453 11.759 4.650 6.974 9.296 11.605 22.336 330 8.455 11.775 4.650 6.974 9.295 11.598 22.194 340 8.457 11.788 4.650 6.974 9.293 11.590 22.031 350 8.458 11.798 4.650 6.974 9.290 11.579 21.842 360 8.459 11.807 4.650 6.973 9.287 11.564 21.624 370 8.460 11.814 4.650 6.973 9.282 11.545 21.372 380 8.460 11.820 4.650 6.972 9.274 11.519 21.081 390 8.460 11.825 4.650 6.970 9.263 11.485 20.745 400 8.461 11.829 4.650 6.968 9.248 11.440 20.357 410 8.461 11.832 4.649 6.964 9.226 11.379 19.909 420 8.461 11.835 4.649 6.957 9.195 11.300 19.391 430 8.461 11.837 4.649 6.948 9.152 11.196 18.793 440 8.461 11.838 4.647 6.931 9.089 11.054 18.103 450 8.461 11.840 4.645 6.905 9.000 10.869 17.305 460 8.461 11.841 4.641 6.864 8.877 10.628 16.383 470 8.462 11.842 4.632 6.797 8.695 10.298 15.319 L-2011-076 Attachment 4 Page 4 of 8 480 8.462 11.843 4.613 6.690 8.440 9.866 14.089 490 8.462 11.843 4.576 6.524 8.084 9.306 12.670 500 8.462 11.844 4.500 6.247 7.562 8.536 11.032 510 8.462 11.844 4.349 5.811 6.829 7.533 9.145 520 8.462 11.845 4.036 5.131 5.804 6.229 6.983 530 8.462 11.845 3.421 4.002 4.309 4.452 4.548 540 8.462 11.845 2.143 2.242 2.259 2.222 1.960 550 8.462 11.845 0 0 0 0 0 L-2011-076 Attachment 4 Page 5 of 8 FP&L SL-1 Kithermal for 1/4t Outside Surface Flaw -Heatup Transients C E 20 18 16 14 12 10 8 6 4 2 0-50F/hr outside-70*F/hr outside 0 50 100 150 200 250 300 Coolant Temperature

(°F)350 400 450 500 550 L-2011-076 Attachment 4 Page 6 of 8 25 20 15 10 FP&L SL-1 Kithermal for 1/4t Inside Surface Flaw -Cooldown Transients

-20*F/hr Inside.... 30*F/hr Inside 40°F/hr Inside-50F/hr Inside-lO0°F/hr Inside 0 0 50 100 150 200 250 300 Coolant Temperature (F)350 400 450 500 550 L-2011-076 Attachment 4 Page 7 of 8 FP&L SL-1 (Tfluid-Tcrack tip) for 114t Outside Surface Flaw Heatup Transients 60 55 50 45 40-35 30 2 0 15 10 5 0 0 60 120 180 240 300 360 420 480 540 600 Time(min)

L-2011-076 Attachment 4 Page 8 of 8 FP&L SL-1 (Tcrack tip-Tfluid ) for 114t Inside Surface Flaw Cooldown Transients U.12 a..60 55 50 45 40 35 30 25 20 15 10 5 0 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 Time (min)