U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Unit 1 Docket No. 50-335 July 29, 2024 In-Service Inspection Program Owner's Activity Report (OAR-1)

L-2024-123 10 CFR 50.36 10 CFR 50.55a Enclosed is the St. Lucie Unit 1, SL 1-32 outage, Owner's Activity Report, Form OAR-1. The OAR-1 report is prepared, certified, and submitted upon completion of each refueling outage.

The SL 1-32 refueling outage ended on April 13, 2024.

Should you have any questions regarding this submittal, please contact Mr. Kenneth Mack, Senior Manager, Licensing and Regulatory Compliance at 561-904-3635.

Sincerely,

~~

Paulasmus General Manager, Regulatory Affairs

Attachment:

SL 1-32 Refueling Outage OAR-1 Owner's Activity Report cc:

NRC Regional Administrator, Region II NRC Project Manager, St. Lucie Plant NRC Site Resident Inspector, St. Lucie Plant Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

ATTACHMENT OWNER'S ACTIVITY REPORT (OAR-1)

FOR SL 1-32 REFUELING OUTAGE (2 pages follow)

'Report Number: ISI-PSL-1-2024 Plant:

St. Lucie Nuclear Power Plant Unit 1 6501 South Ocean Drive Jensen Beach, Florida 34957 Commercial SeNice Date: December 21, 1976 Refueling Outage No.: SL1-32 Current Inspection lnteNal: ISi-Fifth lnteNal,

!WE-Third lnteNal Current Inspection Period: ISi -Second Period, IWE -Second Period Edition and Addenda of Section XI applicable to the inspection plan:

ISi Fifth lnteNal and IWE Third lnteNal - 2007 Edition through 2008 Addenda L-2024-123 Page 1 of 2 Attachment Date and Revision of Inspection Plan: ISi - 5th lnteNal-lSI-PSL-1-Program Plan Rev. 1 December 1, 2022 IWE 3rd lnteNal-lWE-PSL-1/2-Program Plan Rev. 0, July 15, 2018 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan: Same Code Cases Used: N-532-5. N-706-1. N-722-1, N-729-6, N-892 CERTIFICATE OF CONFORMANCE I certify that (a} the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of SL 1-32 conform to the requirements of Section XI.

Ayod e I e Is ho I a-Sa I a WU p h D Digitally signed by Ayodele lshola-Salawu, PhD.

Signed

' Date:2024.07.2212:16:34-04'00' Date 07/22/2024 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal *injury or property damage or~loss of any kind arising from or connected with this inspection.

  • ' ~

15648AI, I, N, R 7""~ -

Comm1ss1ons _____________ _

nspector's Signature National Board Number and Endorsements 7/23/2024 Date _________ _

TABLE 1 L-2024-123 Page 2 of 2 Attachment ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number NONE NONE NONE TABLE 2 ABSTRACT REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Date Repair/

Class Description Description of Work Completed Replacement Plan Number 2

V09151 Replacement of 4" check valve by welding 4/8/24 SL 1-23043 WO 40849574-01 30" CW Repair Piping IAW EC 298441 Thru-3 CW-21 Wall Leak WO 40872552-02 3/22/24 SL 1-23002 3

V2525 Replacement of valve and adjacent piping 3/22/24 SL 1-23047 by welding. WO 40846939